UPDATED-Comments Reply ABA

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 3

1.

The location of the residential Complex changed – new site layout required (for site plan)
2. Comments for plans:
a. Key plan missing =GENERAL=
We shall added it in GA drawings , its available in FC and RC
b. Steps missing please refer to drawing(steps at doors other than main entrance at gf)
We shall add steps.
c. There is no clear mention to the main stair for the building. The designer put doors and
treat with the 2 stairs as emergency stairs =GROUND FLOOR=
Omit
d. Walkway layout missing = GROUND FLOOR=
Site ?
e. Laundry equipment layout missing = GROUND FLOOR=
To be Provided by Elec.
f. The 2d drawings refer to G+8 floors while the 3D refers to G+6 floors= GENERAL=
Omit
g. Kitchen layout different – Architectural different from Electrical-= GROUND FLOOR=
To be Provided by Elec.
h. Levels notation missing = GENERAL=
We shall add it.
i. Space notation missing (to be provided?) =GENERAL=
Room Tag .DWG for all Rooms
j. Garbage room missing= GROUND FLOOR=

k. Section lines missing = GROUND FLOOR=

Ok.

l. 2 toilets inside the cafeteria with direct access and there are no wash basin sinks just
inside WC? = GROUND FLOOR=
Omit
m. Ramps missing= GROUND FLOOR=
Handicapped ramps shall be added 4 % slope.
n. 1.6m wide for corridor wall to wall without the finishing is too narrow/ 1.75-2.00m
required= TYPICAL FLOORS
Omit.
o. No balconies at all the flats while the location of AUIB project has many lakes and
beautiful views. Please clarify?
Omit.
p. Flats numbering missing
Same in room tags
q. Full description required – Area, name, Finishing codes- for rooms
Same in room tags
r. Service ladder required to reach to top of roof =Roof floor Plan=
We shall add it.
s. Shaft at axis V4,H2 dimensions 70x70 while in structural drawings 40x70? =Roof floor
Plan=
Follow structure.
t. Material finishing codes description required=Roof floor Plan=
We shall add it.
u. Shaft at V3 conflict with wall =Top of Roof Plan=
Adjust wall.
v. Some of the flats don’t have kitchen please clarify. The flats will be served by the main
kitchen in the ground floor? Or another solution? Please clarify =Typical Floors at Staff
building=
Omit.
3. Comments for Elevations
a. Some doors and windows don’t have notation
To be added
b. Exterior Lighting location missing
To be added
c. Color code missing, what does the pattern refer to? Material legend required
To be added
4. Sections:
a. The service rooms at roof don’t have parapet and service ladder, please clarify
To be added
b. Missing doors
c. Wrong door directions
d. False Ceiling levels missing
5. Equipment layout:
a. List of furniture missing
To be added

b. Kitchen layout different from electrical drawings


Follow elec.
6. Ground floor Covering layout:
a. Missing hatch and hatch codes at all spaces
To be added
b. Finishing materials for the service rooms not mentioned in the legend plan

To be added

7. Ground floor reflected ceiling plan :


a. Missing hatch codes
To be added
b. Missing hatch levels
To be added
c. 25cm acoustic ceiling with linear lighting at the corridors and some service rooms seem
not standard and difficult to install the lighting

d. Please confirm tht the RCP coordinate with the ICT drawings
8. First floor plan floor covering layout- DRS:
a. Refer to comments on ground floor
b. Hatch pattern suppose to be same like the legend
c. 30x30 ceramic at bedrooms and sitting areas and 60x60 for bath? This is conflict with the
schedules. Moreover, 100x100 for corridors? While the corridor width 1.6m?
9. External wall sections:
a. Dimensions + Description for ACP covering?
To be added
b. Description color size for aluminum profiles, glass etc
To be added
c. Key plan missing
To be added
d. Description for all materials missing
To be added
e. The section with details suppose to be along all the floors from ground floor to top of
roof
To be added
f. Material codes missing especially for exterior materials
To be added
g. Legend missing
To be added
h. Levels missing
To be added
10. Miscellaneous details:
a. Only one detail for the elevation finishing. Please provide more details
b. Using 60x60 precast paving units, in Iraq we use 80x80 units
11. Aluminum schedule:
a. Quantity missing
To be added
b. Description
c. Location
d. Sample attached for reference

You might also like