Professional Documents
Culture Documents
Grundfos CR CRN Pump Curves
Grundfos CR CRN Pump Curves
Contents
Motor data
ODP motors page 50
TEFC motors page 51
2
Custombuilt.book Page 3 Friday, February 27, 2004 8:21 AM
Pumps
The pump can be custom-built for special operating
conditions and applications such as
• high inlet pressures
• high-pressure systems up to 725 psi
• horizontal mounting
• applications demanding belt-driven pumps
• pharmaceutical and biotechnological applications
• applications requiring low NPSH.
GR5357
3
Custombuilt.book Page 4 Friday, February 27, 2004 8:21 AM
Performance range
H H
[m] [ft] 60 Hz
1500
400
300 1000
800
200
600
400
100
300
80
CR 1s CR 3 CR 10 CR 20 CR 45 CR 90
60 200
CRI 1s CRI 3 CRI 10 CRI 20 CRN 45 CRN 90
50 CRN 1s CRN 3 CRN 10 CRN 20
150 CR 1 CR 5 CR 15 CR 32 CR 64
40 CRI 1 CRI 5 CRI 15 CRN 32 CRN 64
CRN 1 CRN 5 CRN 15
30 100
80
20
60
4 6 8 10 20 30 40 60 80 100 200 300 400 600 800
Q [US GPM]
1 2 3 4 5 6 8 10 20 30 40 50 60 80 100 Q [m³/h]
Eta
[%]
80
60
40
20
4
Custombuilt.book Page 5 Friday, February 27, 2004 8:21 AM
Codes H
Q
Cemented tungsten carbide, embedded (hybrid)
Silicon carbide
Example A -F -A -E -H QQ E U Cemented tungsten carbide
Pump version X Other ceramics
A Basic version 1) E EPDM
B Oversize motor F FXM
E Cetificate/approval K FFKM
CR pump for high temperatures V FKM
F
(air-cooled top assembly) 1) In August 2003 the NEMA version pump code was discontinued for all
H Horizontal version material numbers created by Grundfos manufacturing companies in
High-pressure pump with high North America. The NEMA version pump code will still remain in effect
HS for existing material numbers. NEMA version pumps built in North
speed MLE motor
America after this change will have either an A or U as the pump version
I Different pressure rating
code depending on the date the material number was created.
J Pump with different max speed
K Pump with low NPSH
M Magnetic drive
N Fitted with sensor
P Undersize motor
R Horizontal version with bearing bracket
SF High pressure pump
Over size motor
T
(two flange sizes bigger)
U NEMA version 1)
X Special version
Pipe connection
A Oval flange
B NPT thread
CA FlexiClamp (CRI(E), CRN(E) 1, 3, 5, 10, 15, 20)
CX Triclamp (CRI(E), CRN(E) 1, 3, 5, 10, 15, 20)
F DIN flange
G ANSI flange
J JIS flange
N Changed diameter of ports
P PJE coupling
X Special version
5
Custombuilt.book Page 6 Friday, February 27, 2004 8:21 AM
H H H
[m] [ft] [ft]
220 CR 32 220
200 200
60 -2 CRN 32
180 -2-1 180 QH curves for the individual pumps.
2-pole, 60 Hz
50 160 160 The bold curves indicate the recom-
Number of stages mended performance range for best
First figure indicates number of 140 140 efficiency.
40
stages, second figure indicates 120 120 The thin curves are only to be used as
number of reduced-diameter a guide.
impellers. 30 100 100
80 80
20
60 60
40 40
10
20 20
The power curves indicate
pump input power per stage. 0 0 0
Chart shows curve for pump 0 20 40 60 80 100 120 140 160 Q [US GPM]
with full-diameter impeller (1/1)
and reduced-diameter impeller
(2/3). 0 5 10 15 20 25 30 35 40 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
4 Eff 1/1 80 The eta curve shows pump effi-
3 2/3 60 ciency. The efficiency of pumps
2 with reduced-diameter impellers
2 40
1 1 20 is approx. 2% lower than the eta
0 0 0 curve shown in the chart.
0 20 40 60 80 100 120 140 160 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
NPSHR
8 30 30
The NPSH curve is an average
20 20 curve for all the variants shown.
4 10 10 When sizing the pumps, add a
Curve conditions The curve below shows the minimum flow rate as a
percentage of the nominal flow rate in relation to the
The guidelines below apply to the curves shown in this liquid temperature.
data booklet.
The dotted curve represents a pump fitted with an air-
1. The motors used for the measurements are the same cooled top.
as the motors used in the standard range.
2. Performance may vary based on motor selection. Qmin
3. Measurements have been made with airless water at [%]
a temperature of 68°F. 30
0
not be used at a flow below the minimum flow rate.
104
40 140
60 176
80 212 248
120 284 320 180
140 160 356 t [°F]
6
Custombuilt.book Page 7 Friday, February 27, 2004 8:21 AM
General information
The Grundfos standard range of motors covers a wide
variety of application demands. For special applications
or operating conditions, Grundfos offers custom-built
motors, such as:
Variant Description
If technically possible, Grundfos can fit the pump with a motor of a brand other than the
Different motor brand standard. This will normally increase the time of delivery. Alternatively, the pump can be
supplied without a motor (motor thrust rating must be checked).
Different position of motor Where possible, the terminal box can be placed on either side of the pump.
Explosion-proof motor For operation in hazardous atmospheres.
As standard, Grundfos can supply:
• ODP: open drip-proof; TEFC: total-enclosed fan-cooled
On request, we can supply:
Different enclosure class
• Chemical processing/mill and chem duty
• Washdown duty (Up through 10 hp only)
• Other
Anti-condensation heating Built-in heating unit, especially for humid environments.
(space heaters) All heating units are supplied with 1 x 115V, 60Hz.
All Grundfos CR pumps 10 hp and below are available as standard with an integrated variable
Integrated variable speed drive
speed drive (type MLE) motor.
Special supply voltage Motors suitable for other voltages are available upon request.
Motor insulation class Upgrade from Class F to Class H.
• EPAct/NRC—motor efficiency according to EPAct/NRC standards
Efficiency class
• Premium efficiency
Ambient temperatures above 104° F or installation at altitudes of more than
Oversized motor
3,300 feet above sea level may require the use of an oversized motor (i.e. derating).
Tropicalized windings Motors recommended for operating in areas with high humidity.
Wye/Delta starting Motor wired for Wye/Delta starting (6 leads).
Grundfos’ laboratory is authorized to issue test sheets for motors; for instance,
Test sheets
for insurance companies.
7
Custombuilt.book Page 8 Friday, February 27, 2004 8:21 AM
NEMA TEFC Motor Efficiency Standards & Baldor TEFC Super-E Efficiency
100
95
90
Efficiency (%)
85
80
75
70
1 1.5 2 3 5 7.5 10 15 20 25 30 40 50 60
HP
TEFC EPAct/NRC TEFC Premium Eff. TEFC Super-E
Notes:
1. The term “High Efficiency” is commonly used but is not recognized in the NEMA standards (MG 1-1198, Part 12).
2. Some standard CR pump motors already meet the EPAct/NRC requirement. See the CR, CRI, CRN Product Guide.
NEMA TEFC
Baldor Super-E
Motor
Efficiency
Efficiency Standards &
8
Custombuilt.book Page 9 Friday, February 27, 2004 8:21 AM
General information
Double seals mounted in tandem are recommended for
use with crystallizing, hardening or sticky liquids. Outlet 1/2"
Reference applications
• Pharmaceutical industry (production of dextran)
• Negative pressure deaeration systems (vacuum)
• Industries handling potentially hardening oil
products
• Caustic soda (sodium hydroxide - NaOH)
• Hydrated lime (calcium hydroxide - Ca(OH) 2).
pressure.
• •
Reference numbers
Pump type Reference number
CR, CRI, CRN 1, 3 and 5 98 97 08
CR, CRI, CRN 10, 15 and 20 98 94 70
CR, CRN 32, 45, 64 and 90 98 98 05
TM02 2139 3701
Inlet 1/2"
9
Custombuilt.book Page 10 Friday, February 27, 2004 8:21 AM
Reference applications
Reference numbers
Pump type Reference number
CR, CRI, CRN, 1, 3 and 5 98 97 09
CR, CRI, CRN, 10, 15 and 20 98 94 71
TM02 5000 2002
10
Custombuilt.book Page 11 Friday, February 27, 2004 8:21 AM
Pressure intensifier
Reference numbers
TM01 4459 0399
Reference number
Dosing pump,
max. 232 psi 98 98 09
a b c
Pump type
[in] [in] [in]
CR, CRI, CRN 1, 3 and 5 11 3/4 4 1/4 5
CR, CRI, CRN, 10, 15 and 20 12 3/4 3 1/2 5 1/2
CR, CRN 32 13 1/2 8 1/4 6
CR, CRN 45 13 3/4 9 1/2 6 1/2
CR, CRN 64 13 3/4 6 1/2 6 1/2
CR, CRN 90 14 7 1/4 6 3/4
11
Custombuilt.book Page 12 Friday, February 27, 2004 8:21 AM
60 Hz
CRI, CRN 10-1 --> 10-5
CRI, CRN 15-1 --> 15-2
General information CRI, CRN 20-1
The unique Grundfos air-cooled top shaft seal solution is CR, CRN 32-1-1 --> 32-2
recommended for applications involving high tempera- CR, CRN 45-1-1 --> 45-1
tures from 248°F to 356°F. CR, CRN 64-1-1 --> 64-2-1
CR, CRN 90-1-1 --> 90-2-2
The Cool-Top pumps are equipped with FXM rubber
parts. The max. permissible operating pressure of pumps with
air-cooled top for temperatures up to 356°F is 362 psi.
Reference applications
Dimensions
• Boiler feeding
Additional pump height
• Temperature control, e.g. in moulding processes Pump type
[in]
• Circulation of transmission oils. CRI, CRN 1, 3 and 5 4 1/4
CRI, CRN 10, 15 and 20 3 1/2
Pump range CR, CRN 32 8 1/4
The Cool-Top is available for the following Grundfos CR, CRN 45 9 1/2
pumps: CR, CRN 64 6 1/2
CR, CRN 90 7 1/4
248-356°F
Pump Reference numbers, air-cooled top for 248-356°F
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type
Pump type Reference number
CR z z z z
CRI, CRN 1, 3 and 5 98 96 40
CRI z z z z z z
CRI, CRN, 10, 15 and 20 98 94 73
CRN z z z z z z z z z z
CR 32, 45, 64 and 90 98 96 38
Technical description CRN 32 and 45 98 96 37
CRN 64 and 90 98 96 36
The air-cooled top separates the seal chamber from the
pump by an air-cooled chamber, generating an insu-
lating effect similar to that of a thermos.
Via the narrow passage between the pump and the air-
cooled top, a small quantity of the pumped liquid recir-
culates by natural circulation.
12
Custombuilt.book Page 13 Friday, February 27, 2004 8:21 AM
Sectional drawings
CRI, CRN 1, 3 and 5 CRI, CRN 10, 15 and 20
Air vent
Liquid
Shaft seal
Liquid
Bushing
Shaft seal Air chamber
Air chamber
Pipe
Shaft seal
Liquid
Air Pipe
chamber
•
•
•
•
•
•
•
•
•
Bushing
TM01 4785 0899
13
Custombuilt.book Page 14 Friday, February 27, 2004 8:21 AM
For explanation of codes, see the type key on page 5. Pump range
Min. Max. Pressure Shaft seals with FFKM or FXM O-ring are available for the
Pump type Shaft seal temp. temp. rating following Grundfos pumps:
[°F] [°F] [psi]
HUBx 32 248 435 Pump
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type
CR, CRI, CRN HUUx –40 194 435
1s, 1, 3, 5, 10, 15, 20, FFKM z z z z z z z z z z z
32, 45, 64, and 90 HQQx –40 248 435
FXM z z z z z z z z z z z
HQBx 0 248 435
Technical description
Rubber type Min. temperature [°F] Max. temperature [°F]
The FFKM and FXM O-rings replace the standard shaft
EPDM –40 248
seal O-rings.
FKM –4 194
FXM 14 527 Dimensions
FFKM –4 527
Dimensions are identical to those of the standard shaft
Maximum operation temperature is 248°F for the standard range. seal.
Pumps equipped with an Cool-Top the maximum opera-
tion temperature is 356°F. Reference numbers
Reference number
Pump type
FFKM FXM
CR, CRI, CRN 1s, 1, 3 and 5 98 99 72 98 96 78
CR, CRI, CRN 10, 15 and 20 98 94 74 98 94 75
CR, CRN 32, 45, 64 and 90 98 98 15 98 96 77
14
Custombuilt.book Page 15 Friday, February 27, 2004 8:21 AM
General information
Hybrid shaft seals are recommended for applications
involving a risk of dry running and are available as a
standard shaft seal on CR, CRN 32, 45, 64 and 90; seal
type KUHE.
Reference applications
• Boiler-feed applications
• Applications involving degassing of liquids
• Industrial applications involving frequent priming.
Pump range
15
Custombuilt.book Page 16 Friday, February 27, 2004 8:21 AM
Certificates
ATEX-approved pump
Customer name
Customer order no.
Grundfos order no.
Pump type
Part number
Production code
Pump serial no.
Motor serial no.
ATEX approval of pump
Grundfos hereby confirms that the pump mentioned above is manufactured according the
specifications mentioned in the “CR, CRI, CRN Custom-built pumps” data booklet. This means
the pump is conformity with the ATEX 94/9EEC (ATEX 100) appendix VIII directive as men-
tioned in the “ATEX Supplement to installation and operating instructions” supplied with the
pump.
Surface roughness
According to ISO 1302
Customer name
Customer order no.
Grundfos order no.
Pump type
Part number
CRN base part number
The surface roughness is measured as the maximum roughness of the CRN inlet and outlet
surface.
GRUNDFOS
Date: 7-Jan-04
Signature:
Name:
Dept.:
Part no 96 51 22 40/A51137
1.6 N7
Measured values 0.8 N6
R max µm 0.4 N5
0.2 N4
RT µm
0.1 N3
RA µm 0.05 N2
RZ µm 0.025 N1
Vibration report
According to ISO 10816
GRUNDFOS
Measured object Date: 7-Jan-04
Pump type Part number
Test conditions
Frequency (Hz)
Serial no.
Signature:
Name:
Dept.:
Part no 96 50 79 31/A51137
The pump is floor- Voltage (V) Frequency: (Hz)
mounted on vibration
Remarks
• material certificates
0.71
3 1.12
B
1.8
4 2.8
B
C
5 4.5
C
7.1
6
• performance certificates
(printed test reports guaranteeing and certifiing test GRUNDFOS
Date: 7-Jan-04
Signature:
Part no 96 50 79 32/A51137
16
Custombuilt.book Page 17 Friday, February 27, 2004 8:21 AM
ATEX-approved CR pumps
General information
The CR pumps can be approved according to EC directive
94/9/EC, the so-called ATEX directive.
The pumps can be used in areas (zones) classified
according to the directive 1999/92/EC. In case of doubt,
please consult the above-mentioned directives or
contact Grundfos.
ATEX-approved pumps will be supplied with serial
number, special installation and operating instructions
and a nameplate including the ATEX classification.
An ATEX-approved pump report is available on request.
Group II
Category 2 Category 3
Installation areas liable to be endan- Pumps intended for use in areas in which Pumps intended for use in areas in which
gered by explosive atmospheres. explosive atmospheres are likely to occur. explosive atmospheres only rarely occur.
G (gas) D (dust) G (gas) 2) D (dust)
CR pumps available CR, CRI, CRN 1) CR, CRI, CRN, CRT CR, CRI, CRN, CRT CR, CRI, CRN, CRT
VEM 2G EEx e IIT3 VEM 2G EEx e IIT3
Motors available VEM 2D 125°C VEM 3D 125°C
CEMP 2G EEc d IIB T4 CEMP 2G EEc d IIB T4
1)
Solutions including MAGdrive or double shaft seal.
2) Note: To enable the use of category 3 G CR pumps in zone 1 areas, the minimum requirement is a dry-running protection aprroved for zone 1.
The dry-running protection must stop the pumps if the liquid supply ceases.
17
Custombuilt.book Page 18 Friday, February 27, 2004 8:21 AM
Axial bearing
259
Above information is required for the selection of the
correct MAGdrive/motor combination.
18
Custombuilt.book Page 19 Friday, February 27, 2004 8:21 AM
L1
L2
L3
N
Sensor
K1
T+
T+
M
White
Yellow
Black
Brown
General information
The Grundfos LiqTec dry-running sensor stops the pump
immediately if there is no liquid present in the pump.
The LiqTec also serves as overheating protection of the
motor.
The sensor is easily inserted through the pump head
close to the shaft seal.
Pump range
The LiqTec is available for the following Grundfos Dimensions
pumps:
4 5/8 x 3 9/16 in. The LiqTec can be fitted to a DIN rail to
Pump be incorporated in a control cabinet.
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type
CR z z z z z z z z z z z Operating range
CRI z z z z z z z
1 x 80-130 V or
CRN z z z z z z z z z z z Power supply
1 x 200-240 V
Power consumption 5W
Technical description
Max. pressure 580 psi
The LiqTec transmits a heat impulse through the sensor, Min./max. liquid temperature –4°F/248°F
measuring the temperature of the sensor. Liquid in the Max. ambient temperature 104°F
pump cools the sensor as well as the shaft seal and other Humidity 99%
pump parts. Pumped liquid Any liquid handled by Grundfos pumps
If there is no liquid present, the LiqTec detects a high Cable length 16 1/2 / 49 1/4 feet
temperature in the sensor and cuts out the pump imme- Reference numbers
diately to prevent damage. The risk of pump breakdown
is thus further reduced by up to 50%. Pump type Reference number
CR, CRI, CRN 1s, 1, 3, 5, 10, 15, 20, 32, 45, 64 and 90 99 96 82
Restarting after a pump cut-out can be done automati-
cally or manually when liquid in the pump is again
detected by the sensor. Remote restarting is possible via
a digital input.
The electronic control unit can also be connected to the
pump thermistor measuring the motor temperature. In
case of overheating of the motor, the system cuts out
the pump. For installation of the Grundfos LiqTec, see
the installation example in the right column.
19
Custombuilt.book Page 20 Friday, February 27, 2004 8:21 AM
H
GR5379
L
X
C
General information
For safety and space-saving reasons, the pump can be
• Ships
• Earthquake areas (low center of gravity) CR, CRI, CRN 10, 15 and 20 >=7.5 Hp
• Places with limited access and space. B1
Pump range
The following Grundfos pumps are available for hori-
H
zontal mounting:
L
Pump X
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type
CR z z z z z z z z z z z
CRI z z z z z z z AB
8
CRN z z z z z z z z z z z
D
Technical description
B
X
• CR, CRN 32, 45, 64 and 90.
L
Reference numbers
Pump type Reference number
CR, CRI, CRN 1s, 1, 3 and 5 98 99 51
CR, CRI, CRN 10, 15 and 20 <= 5 Hp 98 94 76
CR, CRI, CRN 10, 15 and 20 >= 7.5 Hp 98 94 77 256
AAA
TM02 7426 3403
AA
A
4 x ø19
BB
B
20
Custombuilt.book Page 21 Friday, February 27, 2004 8:21 AM
Dimensions
CR, CRI, CRN 1s, 1 , 3 and 5, support for base plate and pump head
X X
[in] [in]
Motor B H L C Connections
[hp] [in] [in] [in] [in] ANSI Oval, PJE, FlexiClamp
1/2-2 B1-3 3/8
3-5 5 1/2 5 1/2 2 B1-3 1/4 4 1/8 3 1/8
7 1/2-10 B1-4 7/8
For pump height B1, see the CR, CRI, CRN Product Guide.
CR, CRI, CRN 10, 15 and 20, support for base plate and pump head
CR, CRI, CRN 10 CR, CRI, CRN 15/20
X X
[in] [in]
Motor B H L C Connections
[hp] [in] [in] [in] [in] ANSI, Oval, PJE, Flexiclamp ANSI, Oval, PJE, Flexiclamp
1/2-2 B1-3 1/4
6 3/4 6 7/8 2 4 3/8 4 3/4
3-5 B1-4 3/8
For pump height B1, see the CR, CRI, CRN Product Guide.
CR, CRI, CRN 10, 15 and 20, support for base plate and motor
CR, CRI, CRN 10 CR, CRI, CRN 15/20
X X
[in] [in]
Motor A AA AAA B BB D H L AB Connections
[hp] [in] [in] [in] [in] [in] [in] [in] [in] [in] ANSI, Oval, PJE, Flexiclamp ANSI, Oval, PJE, Flexiclamp
7 1/2 8 1/2 2 7/8 14 1/2 5 1/2 7 1/8 2 5/8 7 7/8 1 /4 10 7/8
10 8 1/2 2 7/8 14 1/2 5 1/2 7 1/8 2 5/8 7 7/8 1 /4 10 7/8
15 10 5 1/8 16 3/4 8 1/4 10 1/4 1 1/2 7 7/8 1 /4 12 3/4 4 3/8 4 3/4
20 10 5 1/8 16 3/4 8 1/4 10 1/4 1 1/2 7 7/8 1 /4 13 1/8
25 10 5 1/8 16 3/4 10 12 1/4 1 1/2 7 7/8 1 /4 13 1/8
CR, CRN 32, 45, 64 and 90, support for base plate and motor
CR, CRN 32 CR, CRN 45, 64, 90
X X
[in] [in]
Motor A AA AAA B BB D AB H L Connection
[hp] [in] [in] [in] [in] [in] [in] [in] [in] [in] ANSI
2 5 1/2 12 5/8 15 5 6 1/2 7 7/8 8 5/8 11 3/8 2 3/8
3 5 1/2 12 5/8 15 5 6 1/2 7 7/8 8 5/8 11 3/8 2 3/8
5 7 1/2 14 1/2 17 5 1/2 7 1/8 7 10 7/8 11 3/8 2 3/8
7 1/2 8 1/2 15 1/2 18 5 1/2 7 1/8 6 1/4 11 7/8 11 3/8 2 3/8
10 8 1/2 15 1/2 18 5 1/2 7 1/8 6 1/4 11 7/8 11 3/8 2 3/8
15 10 17 3/8 19 5/8 8 1/4 10 7/8 5 1/8 13 3/8 11 3/8 2 3/8
8 3/8 7
20 10 18 20 1/4 8 1/4 10 1/2 5 1/8 13 3/8 11 3/8 2 3/8
25 10 18 20 1/4 10 12 1/4 5 1/8 13 3/8 11 3/8 2 3/8
30 11 19 21 1/2 9 1/2 12 1/4 4 3/8 14 3/8 11 3/8 2 3/8
40 12 1/2 21 1/4 23 5/8 12 14 3/8 3 1/2 16 1/8 11 3/8 2 3/8
50 12 1/2 21 1/4 23 5/8 12 14 3/8 3 1/2 16 1/8 11 3/8 2 3/8
60 14 22 7/8 25 1/4 12 1/4 14 1/2 2 1/2 17 3/4 11 3/8 2 3/8
21
Custombuilt.book Page 22 Friday, February 27, 2004 8:21 AM
Pumps with bearing flange The bearing flange requires a standard motor with
keyway.
Note: For motor sizes above 15 hp, the bearing flange is
equipped with grease nipples and must be lubricated
regularly. Please follow the instructions on the bearing
Bearing flange flange.
Sectional drawings
CR, CRI, CRN 1s, 1, 3, 5, <= 7.5 Hp
CR, CRI, CRN 10, 15 and 20 , <= 5 Hp
NEMA 56 C - NEMA 213-5 TC
General information
Reference applications
High-pressure applications such as
• cleaning
Pump range
The following Grundfos pumps are available with CR, CRN 32, 45, 64 and 90, <= 10.0 Hp
bearing flange: NEMA 182 TC - NEMA 215 TC
Pump
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type
CR z z z z z z z z z z z
CRI z z z z z z z
CRN z z z z z z z z z z z
Technical description
TM01 4352 0199
22
Custombuilt.book Page 23 Friday, February 27, 2004 8:21 AM
23
Custombuilt.book Page 24 Friday, February 27, 2004 8:21 AM
GR5886
motor mounted next to it rather than on top of it.
The pump can be mounted horizontally or vertically by
General information using the extra support plates.
A belt-driven pump is designed to operate in places with The pulley head is positioned on the motor stool where
limited space or where no electrical power is available. the motor would normally be fitted. Using the existing
holes in the motor stool, the pulley head can be secured
Reference applications to the motor stool with bolts, washers and nuts. The
Diesel-engine-driven or steam-turbine-driven applica- pulley wheel is then attached to the shaft using an
tions such as: appropriate bush and key.
• applications in remote/distant areas For extended bearing life, the following pulley wheel
sizes are recommended:
• mobile applications
Type III Type IV Type II Type I
• fire protection. Pulley head
1/2 - 7 1/2 Hp 10 - 25 Hp 2 - 10 Hp 15 - 60 Hp
Pump range CR, CRI, CRN
CR, CRI, CRN CR, CRN
Pump type 1s, 1, 3, 5,
The following Grundfos pumps are available as belt- 10, 15, 20
10, 15, 20 32, 45, 64, 90
driven pumps:
Pulley wheel Min.
ø4 3/8- 5 3/8 Min. ø7 7/8 Min. ø6 1/4
Pump diameter ø7 7/8
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type Number of belts 2 Min. 3 Min. 2 Min. 3
CR z z z z z z z z z z z Pump speed
Max 3000
CRI z z z z z z z [rpm]
CRN z z z z z z z z z z z
24
Custombuilt.book Page 25 Friday, February 27, 2004 8:21 AM
25
Custombuilt.book Page 26 Friday, February 27, 2004 8:21 AM
Dimensions
Dimensions are identical to those of a standard pump.
Reference numbers
Pump type Reference number
CRI, CRN 1s, 1, 3 and 5 98 98 75
GR5219
CRI, CRN 10, 15 and 20 98 94 78
General information
Grundfos offers pumps suitable for the pumping of
liquids of extreme temperatures down to –40°F.
Reference applications
• Cooling systems with antifreeze and brines
• Ventilation systems
• Industrial processes.
Pump range
The following Grundfos pumps are available for liquid
temperatures down to –40°F:
Pump
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type
CR
CRI z z z z z z z
CRN z z z z z z z
The standard CRN 32, 45, 64 and 90 pumps fitted with shaft seal type
HQQE are capable of operating at liquid temperatures down to –40°F.
26
Custombuilt.book Page 27 Friday, February 27, 2004 8:21 AM
Reference numbers
Pump type Reference number
CR, CRI, CRN 1s, 1, 3, 5, 10, 15 and 20
98 99 54
CR, CRN 32, 45, 64 and 90
27
Custombuilt.book Page 28 Friday, February 27, 2004 8:21 AM
Solutions
Grundfos offers the following solutions to meet these
special requirements:
• TriClamp connection
• Cleaned and dried pumps
• Electropolished pumps.
GR5841_base
Reference numbers
Base with TriClamp connection
Pump type Reference number
CRI, CRN 1s, 1, 3 and 5 98 96 92
CRI, CRN 10 , 15 and 20 98 94 79
GR5841_clamp
Part numbers
Two gaskets and two couplings
Pipework Gasket Part
Pump type
connection parts number
CRI, CRN 1s, 1, 3 and 5 1 1/2" EPDM 96 51 53 74
CRI, CRN 1s, 1, 3 and 5 1 1/2" PTFE 96 51 53 75
CRI, CRN 10 , 15 and 20 2" EPDM 96 51 53 76
CRI, CRN 10 , 15 and 20 2" PTFE 96 51 53 77
28
Custombuilt.book Page 29 Friday, February 27, 2004 8:21 AM
Dimensions
Dimensions are identical to those of the standard pump.
Reference numbers
Pump type Reference number
CRN 1s, 1, 3, 5 98 97 60
CRN 10, 15, 20 98 94 80
CRN 32, 45, 64, 90 98 96 25
29
Custombuilt.book Page 30 Friday, February 27, 2004 8:21 AM
General information
The low-NPSH pumps are designed for poor suction
conditions and/or high application temperatures.
The pumps are specially suited for handling poor inlet
flows and liquid temperatures above 140°F.
30
Custombuilt.book Page 31 Friday, February 27, 2004 8:21 AM
H H H
[m] [ft] [ft]
800 CR 3 800
240 -25
750 CRI 3 750
220
700
-23 CRN 3 700
550 550
160 -17
500 500
140 -15
450 450
-13
120 400 400
-12
350 -11 350
100
-10
300 300
-9
80
250 -8 250
-7
60 200 200
-6
150 -5 150
40 -4
100 -3 100
20
50 50
0 0 0
0 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM]
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
P2
0.15 60
0.10
0.10 Eff 40
0.05
0.05 20
0.00 0.00 0
0 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
15 NPSHR 15
4
10 10
Low NPSHR
2
5 5
TM02 8378 5103CR 3
0 0 0
0 2 4 6 8 10 12 14 16 18 20 22 24Q [US GPM]
31
Custombuilt.book Page 32 Friday, February 27, 2004 8:21 AM
H H H
[m] [ft] [ft]
800 CR 5 800
240 -24
750 CRI 5 750
220
700 -22 CRN 5 700
200 2-pole, 60 Hz
650 -20 650
150 -5 150
40 -4
100 100
20
50 50
0 0 0
0 5 10 15 20 25 30 35 40 45 Q [US GPM]
0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
0.3 P2 60
0.2 Eff
0.2 40
0.1
0.1 20
0.0 0.0 0
0 5 10 15 20 25 30 35 40 45 Q [US GPM]
H NPSH NPSH
[m] [ft] NPSHR [ft]
15 15
4
10 10
2 Low NPSHR
5 5
TM02 8379 5103CR 5
0 0 0
0 5 10 15 20 25 30 35 40 45 Q [US GPM]
32
Custombuilt.book Page 33 Friday, February 27, 2004 8:21 AM
H H H
[m] [ft] [ft]
800
-17 CR 10 800
240
750
-16 CRI 10 750
220
700 CRN 10 700
0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 Q [US GPM]
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
0.8 80
P2
0.6 Eff 60
0.4
0.4 40
0.2
0.2 20
0.0 0.0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
NPSHR
15 15
4
10 10
2
5 Low NPSHR 5
TM02 8380 5103CR 10
0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 Q [US GPM]
33
Custombuilt.book Page 34 Friday, February 27, 2004 8:21 AM
H H H
[m] [ft] [ft]
850 CR 15 850
-12
240
800 CRI 15 800
0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 Q [US GPM]
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
2.0 Eff 80
1.5 P2 60
1.0
1.0 40
0.5
0.5 20
0.0 0.0 0
0 10 20 30 40 50 60 70 80 90 100 110 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
NPSHR
15 15
4
10 10
2 Low NPSHR
5 5
TM02 8381 5103CR 15
0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 Q [US GPM]
34
Custombuilt.book Page 35 Friday, February 27, 2004 8:21 AM
H H H
[m] [ft] [ft]
CR 20
600 600
180
-8 CRI 20
550 550
CRN 20
160
500
-7 2-pole, 60 Hz 500
140
450 450
-6
80
250 250
-3
60 200 200
-2
150 150
40
100 100
20
50 50
0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [US GPM]
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
4 Eff 80
3 60
2
P2
2 40
1
1 20
0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
30 30
8 NPSHR
20 20
4
10 10
TM02 8382 5103CR 20
Low NPSHR
0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [US GPM]
35
Custombuilt.book Page 36 Friday, February 27, 2004 8:21 AM
H H H
[m] [ft] [ft]
CR 32
-10-2
900 CRN 32 900
-9 2-pole, 60 Hz
250 -9-2
800 800
-8
-8-2
700 700
200 -7
-7-2
600 600
-6
-6-2
150 500 500
-5
-5-2
400 400
-4
-4-2
100
300 300
-3
-3-2
200 -2 200
50 -2-1
100 100
0 0 0
0 20 40 60 80 100 120 140 160 180 200 Q [US GPM]
0 5 10 15 20 25 30 35 40 45 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
4 Eff P2 1/1 80
3 P2 2/3 60
2
2 40
1
1 20
0 0 0
0 20 40 60 80 100 120 140 160 180 200 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
30 NPSHR 30
8
20 Low NPSHR 20
4
10 10
TM02 8383 5103CR 32
0 0 0
0 20 40 60 80 100 120 140 160 180 200 Q [US GPM]
36
Custombuilt.book Page 37 Friday, February 27, 2004 8:21 AM
H H H
[m] [ft] [ft]
CR 45
900 CRN 45 900
-7
-7-1
-7-2
2-pole, 60 Hz
250
800 800
-6
-6-1
700 -6-2 700
200
600 -5 600
-5-1
-5-2
-2
-2-1
200 200
50
100 100
0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [US GPM]
0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
6 Eff
8 P2 1/1 80
6 P2 2/3 60
4
4 40
2
2 20
0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
30 30
8
20 NPSHR 20
4
10 10
TM02 8384 5103CR 45
Low NPSHR
0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [US GPM]
37
Custombuilt.book Page 38 Friday, February 27, 2004 8:21 AM
H H H
[m] [ft] [ft]
CR 64
600 -5-2 600
180
-4
CRN 64
550 2-pole, 60 Hz 550
160 -4-1
500 500
-4-2
140
450 450
-3
350 350
100 -3-2
300 300
-2
80
250 -2-1 250
60 200 200
150 150
40
100 100
20
50 50
0 0 0
0 40 80 120 160 200 240 280 320 360 400 440 Q [US GPM]
0 10 20 30 40 50 60 70 80 90 100 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
12 16 80
Eff
12 P2 1/1 60
8
8 P2 2/3 40
4
4 20
0 0 0
0 40 80 120 160 200 240 280 320 360 400 440 Q [US GPM]
H H NPSH
[m] [ft] [ft]
30 NPSHR 30
8
20 20
4 Low NPSHR
10 10
TM02 8385 5103CR 64
0 0 0
0 40 80 120 160 200 240 280 320 360 400 440 Q [US GPM]
38
Custombuilt.book Page 39 Friday, February 27, 2004 8:21 AM
Reference numbers
Pump type Reference number
CR, CRI, CRN 1, 3, 5, 10, 15 and 20
General information 99 97 24
CR, CRN 32, 45 and 64
CR standard pumps fitted with 4-pole motors.
Dimensions and weights
Reference applications CR pumps with 4-pole motors will be shorter in height
• Applications where a low sound pressure level is and weigh less than standard Grundfos CR pumps. This
required is due to the smaller horsepower motors and motor
• Applications with poor inlet conditions. stools required to power the pump at 4-pole perfor-
mance.
Pump range
The following Grundfos pumps are available as 4-pole
versions:
Pump
CR 1s CR 1 CR 3 CR 5 CR 10 CR 15 CR 20 CR 32 CR 45 CR 64 CR 90
type
CR z z z z z z z z z z
CRI z z z z z z
CRN z z z z z z z z z z
39
Custombuilt.book Page 40 Friday, February 27, 2004 8:21 AM
H H H
[m] [ft] [ft]
CR 1
200 200
60 -27 CRI 1
180 -25 CRN 1 180
4-pole, 60 Hz
-23
50
160 160
-21
-15
30 100 100
-13
-12
80 -11 80
-10
20 -9
60 -8 60
-7
-6
40 40
-5
10
-4
20 -3 20
-2
0 0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [US GPM]
0.000 0.000 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
3 3
0.8
2 2
0.4
1 NPSHR 1
TM02 8386 5103CR 1
0.0 0 0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [US GPM]
40
Custombuilt.book Page 41 Friday, February 27, 2004 8:21 AM
H H H
[m] [ft] [ft]
CR 3
200 200
60 -25 CRI 3
180 -23
CRN 3 180
4-pole, 60 Hz
50 -21
160 160
-19
140 140
40 -17
120 120
-15
0 0 0
0 1 2 3 4 5 6 7 8 9 10 11 Q [US GPM]
0.00 0.00 0
0 1 2 3 4 5 6 7 8 9 10 11 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
3 3
0.8
2 2
NPSHR
0.4
1 1
TM02 8387 5103CR 3
0.0 0 0
0 1 2 3 4 5 6 7 8 9 10 11 Q [US GPM]
41
Custombuilt.book Page 42 Friday, February 27, 2004 8:21 AM
H H H
[m] [ft] [ft]
CR 5
200 200
60 -24 CRI 5
180
CRN 5 180
-22
4-pole, 60 Hz
50 -20
160 160
-18
140 140
40 -16
120 -15 120
-14
-13
30 100 100
-12
-11
80 -10 80
-9
20 -8
60 60
-7
-6
40 -5 40
10 -4
-3
20 20
-2
0 0 0
0 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM]
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
0.04 P2 80
0.03 60
0.02 Eff
0.02 40
0.01
0.01 20
0.00 0.00 0
0 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
1.2 4 4
3 3
0.8
2 2
0.4
1 1
NPSHR
TM02 8388 5103CR 5
0.0 0 0
0 2 4 6 8 10 12 14 16 18 20 22 Q [US GPM]
42
Custombuilt.book Page 43 Friday, February 27, 2004 8:21 AM
H H H
[m] [ft] [ft]
CR 10
220 220
CRI 10
-17
60
200 -16 CRN 10 200
4-pole, 60 Hz
180 180
-14
50
160 160
-12
140 140
40
-10
120 120
-9
30 100 -8 100
-7
80 80
-6
20 -5
60 60
-4
40 -3 40
10
-2
20 20
-1
0 0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Q [US GPM]
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
0.12 Eff 60
0.08
P2
0.08 40
0.04
0.04 20
0.00 0.00 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
6 6
4 4
1
2 2
TM02 8389 5103CR 10
NPSHR
0 0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Q [US GPM]
43
Custombuilt.book Page 44 Friday, February 27, 2004 8:21 AM
H H H
[m] [ft] [ft]
CR 15
200 -12 200
60 CRI 15
180
CRN 15 180
4-pole, 60 Hz
-10
50
160 160
-9
140 140
-8
40
120 -7 120
100 -6 100
30
-5
80 80
-4
20
60 60
-3
40 40
-2
10
20 -1 20
0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 Q [US GPM]
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
Eff
0.3 60
0.2
0.2 P2 40
0.1
0.1 20
0.0 0.0 0
0 5 10 15 20 25 30 35 40 45 50 55 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
1.5 1.5
0.4
1.0 1.0
NPSHR
0.2
0.5 0.5
TM02 8390 5103CR 15
44
Custombuilt.book Page 45 Friday, February 27, 2004 8:21 AM
H H H
[m] [ft] [ft]
CR 20
180 -10 CRI 20 180
50 CRN 20
160 160
4-pole, 60 Hz
140 -8 140
40
-7
120 120
-6
30 100 100
-5
80 80
-4
20
60 60
-3
40 40
-2
10
20 -1 20
0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Q [US GPM]
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Q [m³/h]
P2 P2 Eff
[kW] [hp] Eff [%]
0.3 60
0.2
P2
0.2 40
0.1
0.1 20
0.0 0.0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
8 8
2
6 6
4 4
1
2 2
TM02 8391 5103CR 20
NPSHR
0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Q [US GPM]
45
Custombuilt.book Page 46 Friday, February 27, 2004 8:21 AM
H H H
[m] [ft] [ft]
-10-2 CR 32
220 220
-9
CRN 32
200 -9-2 4-pole, 60 Hz 200
60
-8
180 -8-2 180
50 -7
160 160
-7-2
140 -6 140
40 -6-2
120 120
-5
-5-2
30 100 100
-4
-4-2
80 80
-3
20
60 -3-2 60
-2
40 -2-1 40
-2-2
10
-1
20 -1-1 20
0 0 0
0 10 20 30 40 50 60 70 80 90 100 Q [US GPM]
0 2 4 6 8 10 12 14 16 18 20 22 24 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
0.8 80
0.6 Eff 60
0.4 P2 1/1
0.4 P2 2/3 40
0.2
0.2 20
0.0 0.0 0
0 10 20 30 40 50 60 70 80 90 100 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
8 NPSHR 8
2
6 6
4 4
1
2 2
TM02 8392 5103CR 32
0 0 0
0 10 20 30 40 50 60 70 80 90 100 Q [US GPM]
46
Custombuilt.book Page 47 Friday, February 27, 2004 8:21 AM
H H H
[m] [ft] [ft]
CR 45
220 220
-7 CRN 45
-7-2 4-pole, 60 Hz
200 200
60
180 -6 180
-6-2
50
160 160
-5
30 100 100
-3
80 -3-2 80
20
60 -2 60
-2-2
40 40
10 -1
-1-1
20 20
0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [US GPM]
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
1.6 80
Eff
1.2 60
0.8
P2 1/1
0.8 P2 2/3 40
0.4
0.4 20
0.0 0.0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
6 6
4 4
1
2 NPSHR 2
TM02 8393 5103CR 45
0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Q [US GPM]
47
Custombuilt.book Page 48 Friday, February 27, 2004 8:21 AM
H H H
[m] [ft] [ft]
160 CR 64 160
48
150
-5-2 CRN 64 150
44 4-pole, 60 Hz
140 -4 140
40 130 130
-4-1
36 120 120
-4-2
110 110
32 -3
100 100
-3-1
28 90 90
-3-2
24 80 80
-2
70 70
20
60 -2-1 60
16
50 -2-2 50
12 40 -1 40
30 30
8 -1-1
20 20
4
10 10
0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 Q [US GPM]
0 5 10 15 20 25 30 35 40 45 50 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
2.0 80
Eff
1.5 P2 1/1 60
1.0
1.0 P2 2/3 40
0.5
0.5 20
0.0 0.0 0
0 20 40 60 80 100 120 140 160 180 200 220 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
8 8
2 NPSHR
6 6
4 4
1
2 2
TM02 8394 5103CR 64
0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 Q [US GPM]
48
Custombuilt.book Page 49 Friday, February 27, 2004 8:21 AM
H H H
[m] [ft] [ft]
140
CR 90 140
40
-4-2 CRN 90
130 130
4-pole, 60 Hz
120 -3 120
36
110 110
-3-1
32
100 100
-3-2
28
90 90
80 -2 80
24
70 70
-2-1
20
60 60
-2-2
16
50 50
40 -1 40
12
30 -1-1 30
8
20 20
4
10 10
0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [US GPM]
0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
4 80
3 Eff 60
2
2 P2 1/1 40
1 P2 2/3
1 20
0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [US GPM]
H NPSH NPSH
[m] [ft] [ft]
8 NPSHR 8
2
6 6
4 4
1
2 2
TM02 8395 5103CR 90
0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [US GPM]
49
Custombuilt.book Page 50 Friday, February 27, 2004 8:21 AM
ODP motors
ODP ODP ODP ODP Mtr. ODP ODP ODP Full ODP service ODP
HP PH Baldor motor
Frame S.F. Voltage Eff. % Insul. class KVA code load current Factor current Start current
1 56C 1.35 115/230 55 B K 6.0/3.0 7.0/3.5 28/14
1/3
3 56C 1.35 208-230/460 70 B J 1.5-1.4/0.7 1.7-1.6/0.8 11-10/5.0
1 56C 1.25 115/208-230 66 B H 7.2/4.0-3.6 8.0/4.4-4.0 30/16.5-15
1/2
3 56C 1.25 208-230/460 68 B J 2.2-2.0/1.0 2.6-2.4/1.2 13.2-12/6.0
1 56C 1.25 115/208-230 66 B K 9.6/5.3-4.8 11.4/6.3-5.7 56/31-28
3/4
3 56C 1.25 208-230/460 74 B K 2.7-2.6/1.3 3.1-3.0/1.5 16.8-15.2/7.6
1 56C 1.40 115/208-230 73 B M 10/5.5-5.0 15/8.0-7.5 85/47-42.5
1
3 56C 1.25 208-230/460 74 B J 3.8-3.6/1.8 3.4-3.2/1.6 19.6-17.8/8.9
1 56C 1.15 115/208-230 68 B H 18/9.9-9.0 19.4/10.7-9.7 121/66.8-60.4
1 1/2
3 56C 1.15 208-230/460 75.5 B G 5.0-4.6/2.3 5.4-5.0/2.5 35.4-32/16
1 56C 1.15 115/208-230 70 B G 24/13.2-12 27.6/15.2-13.8 160/88.5-80
2
3 56C 1.15 208-230/460 81.5 B H 5.9-5.6/2.8 6.7-6.4/3.2 41-37/18.5
1 182TC 1.15 115/208-230 78 B G 28/16-14 32/18.3-16.7 148/81.9-74
3
3 182TC 1.15 208-230/460 82.5 F J 8.4-8.0/4.0 9.5-9.0/4.5 66.4-60/30
1 213TC 1.15 208-230 78 B G 28-26 31/28.7 169-152
5
3 182TC 1.15 208-230/460 87.5 B L 13-12/6.0 14.7-13.6/6.8 139-125/62.3
1 213TC 1.15 208-230 81 B G 38-37 42/41 213-192
7 1/2
3 213TC 1.15 208-230/460 85.5 B J 19-18/9.0 21-20/10 169-152/76
1 213TC 1.15 208-230 83 B G 48-46 53.8-51.7 310-280
Notes:
1. The information in this chart applies to Grundfos’
specified Baldor® motors.
Grundfos CR pumps are supplied with heavy-duty
2-pole, NEMA C-frame motors built or selected to our
rigid specifications. All CR pump motors have heavy-
duty bearings in them for maximum thrust require-
ments.
It is not recommended that an off-the-shelf standard
Baldor motor be used on a Grundfos pump. Ideally,
the best motor choice would be the Grundfos speci-
fied motor.
2. Other motor types are available (i.e., Explosion proof,
Mill and Chem duty, High Efficiency, etc.), consult lo-
cal Grundfos company for more information.
3. Pumps supplied by Grundfos Canada are normally
supplied with motors from other manufactures. 575
volt motors meet EPAct/NRC efficiency standards.
Dimensions and data will vary, contact local Grund-
fos company for more information.
4. All values are subject to change without notice.
50
Custombuilt.book Page 51 Friday, February 27, 2004 8:21 AM
TEFC motors
TEFC
TEFC TEFC TEFC TEFC TEFC TEFC Full TEFC service TEFC
HP PH Mtr. Baldor motor
Frame S.F. Voltage Insul. class KVA code load current Factor current Start current
Eff. %
1 56C 1.35 115/230 55 B K 6.0/3.0 7.6/3.8 28/14
1/3
3 56C 1.35 208-230/460 70 B J 1.5-1.4/0.7 1.7-1.6/0.8 11.1-10/5.0
1 56C 1.6 115/208-230 62 B K 7.4/4.1-3.7 9.8/5.2-4.9 39/21.6-19.5
1/2
3 56C 1.25 208-230/460 68 B J 2.1-2.0/1.0 2.6-2.4/1.2 13.3-12/6.0
1 56C 1.25 115/208-230 66 B K 9.6/5.3-4.8 11.4/6.0-5.7 56/31-28
3/4
3 56C 1.25 208-230/460 74 B K 2.7-2.6/1.3 3.1-3.0/1.5 16.9-15.2/7.6
1 56C 1.25 115/230 66 B K 12/6.0 14.4/7.2 77/38.5
1
3 56C 1.25 208-230/460 74 B J 3.4-3.2/1.6 3.8-3.6/1.8 19.6-17.8/8.9
1 56C 1.3 115/208-230 71 B K 17/9.5-8.6 20.4/11.3-10.2 106/58.6-53
1 1/2
3 56C 1.15 208-230/460 75.5 B G 5.0-4.6/2.3 5.4-5.2/2.6 35.4-32/16
1 56C 1.15 115/230 74 F K 23/11.5 25.4/12.7 156/78
2
3 56C 1.15 208-230/460 78.5 B H 5.7-5.4/2.7 6.5-6.2/3.1 38.7-35/17.5
1 182TC 1.15 115/208-230 75 F H 29/16-14.5 31.8/18-15.9 170/94-85
3
3 182TC 1.15 208-230/460 81.5 F K 8.2-7.8/3.9 9.0-8.6/4.3 77.4-70/35
1 213TC 1.15 208-230 80 F J 24-22 27-25 188-170
5
3 184TC 1.15 208-230/460 85.5 F K 13.2-12/6.0 15-13.6/6.8 104-94/47
1 213TC 1.15 208-230 82 F F 33.8-31 38.5-35.5 244-220
7 1/2
3 213TC 1.15 208-230/460 87.5 H L 19-17.2/8.6 21.7-19.6/9.8 169-152/76
1 213TC 1.15 230 85.5 F F 40 46 284
Notes:
1. The information in this chart applies to Grundfos’
specified Baldor® motors.
Grundfos CR pumps are supplied with heavy-duty
2-pole, NEMA C-frame motors built or selected to our
rigid specifications. All CR pump motors have heavy-
duty bearings in them for maximum thrust require-
ments.
It is not recommended that an off-the-shelf standard
Baldor motor be used on a Grundfos pump. Ideally,
the best motor choice would be the Grundfos speci-
fied motor.
2. Other motor types are available (i.e., Explosion proof,
Mill and Chem duty, High Efficiency, etc.), consult lo-
cal Grundfos company for more information.
3. Pumps supplied by Grundfos Canada are normally
supplied with motors from other manufactures. 575
volt motors meet EPAct/NRC efficiency standards. Di-
mensions and data will vary, contact local Grundfos
company for more information.
4. All values are subject to change without notice.