Technical specifications

Model TE-SS835P
Type of device Syringe pump
Classification and compliance Class I and internally powered equipment, Defibrillation-proof type CF applied part (according to IEC/EN 60601-1)
to standards Class IIb medical device (according to Council Directive 93/42/EEC) IEC/EN60601-1-2, IEC/EN 60601-2-24
Protection against harmful ingress
IP 24
of water or particulate matter
Dimensions / Weight 381 mm (W) x 120 mm (H) x 112 mm (D) / approx. 2.0 kg
Compatible disposables Luer lock syringes (TERUMO and other specified brands), Sizes: 5, 10, 20, 30, 50/60 mL
Dose mode mL/h, μg/kg/min, mg/kg/h, mg/kg/h+DIPRIVAN, Drug Library, TCI
T arget Plasma/ Effect-site concentration (Cpt/Cet) Propofol: 0.0 to 15.0 µg/mL (0.1 µg/mL step),
Remifentanil: 0.0 to 50.0 ng/mL (0.1 ng/mL step)
Dilution Propofol: 1%, 2%; Remifentanil: 0.1 to 100.0 µg/mL (0.1 µg/mL step), 100.0 to 500.0 µg/mL (1.0 µg/mL step)
Age Propofol: 16 to 100 (1 year step), Remifentanil: 12 to 100 (1 year step)
TCI Infusion setting range Height 100 to 250 cm (1 cm step)
Weight 30 to 200 kg (0.1 kg step)
Flow rate display range 0.0 to 1200.0 mL/h (0.1 mL/h step)
Volume delivered display range 0.0 to 9999.0 mL (0.1 mL step)
Dose rate display range 0 .00 to 999.00 mg/kg/h (0.01 step), 0.00 to 999.00 µg/kg/min (0.01 step)
Flow rate setting range 0.01 to 150 mL/h (for 5 mL syringes), 0.01 to 300 mL/h (for 10, 20 and 30 mL syringes),
(in other dose modes than TCI) 0.01 to 1200 mL/h (for 50/60 mL syringes)
Flow rate display change 0.01 mL/h step (0.01 to 10.00 mL/h), 0.10 mL/h step (10.00 to 100.00 mL/h)
(in other dose modes than TCI) 1.00 mL/h step (100.00 to 1200.00 mL/h) (Will be 0.00 mL/h when power is turned on)
Interval/intermittent mode, Multi-step mode, Delayed start mode
Advanced dose mode
(To be able to use the advanced mode, the drug library2 needs to be installed).
Combination dose mode Take Over
KVO1 Configurable: 0.10 to 3.00 mL/h, 0.1 mL/h step
Drug library 2
Up to 3000 drug entries. Up to 30 user defined profiles.
Occlusion, Pressure*, Nearly Empty, Slider Displacement, Syringe Barrel Detection, Syringe Displacement, Plunger
Displacement, Battery, Re-alarm, Shutdown Notice, Power Failure, Start Reminder, No Flow Rate, No VTBI**,
Alarms Completion**, Link Interruption*
* Except the TCI mode ** Only if the VTBI setting function is enabled (except the TCI mode) (default: disabled)
Power supply AC 100-240V, 50-60 Hz, Internal battery (Lithium ion battery), Sub-battery (NiMH)
Main battery operating time Approx. 8 hours (at 5 mL/h and 25°C with a new fully charged battery)
Main battery recharging time ≥8 hours (when charged with AC power supply with the power turned off), battery can be charged to 80% in 3 hours
External communication function IrDA and Wireless LAN (IEEE802.11b/g/n)

1 Keep vein open: special function that can be enabled by TERUMO trained service technicians by changing the internal settings of the pump.
2 For installation separate dedicated software is required - please contact your local Terumo office.
MP216GB-0220FK-I(02.20)E

Terumo Corporation
+81 3 3374 8111 Please refer to the instructions for use.

Terumo Europe NV ™ Trademark


www.terumo-europe.com +32 16 38 12 11 All brand names are trademarks or registered trademarks of TERUMO CORPORATION and their respective owners.

You might also like