PVsyst - Simulation report


Grid-Connected System

PVsyst TRIAL
Project: Projeto_Piloto_2
Variant: New simulation variant
Tables on a building
System power: 9.00 kWp
Souzas - Brazil

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL Author


Project: Projeto_Piloto_2
Variant: New simulation variant

PVsyst V7.2.2
VC0, Simulation date:
31/05/21 11:03
with v7.2.2

Project summary
Geographical Site Situation Project settings
Souzas Latitude -22.88 °S Albedo 0.20
Brazil Longitude -46.96 °W
Altitude 667 m

PVsyst TRIAL
Time zone UTC-3

Meteo data
Souzas
Meteonorm 8.0 (2008-2015), Sat=100% - Synthetic

System summary
Grid-Connected System Tables on a building

PV Field Orientation Near Shadings User's needs


Fixed plane Detailed electrical calculation Unlimited load (grid)
Tilt/Azimuth 30 / -20 ° acc. to module layout

System information

PVsyst TRIAL
PV Array Inverters
Nb. of modules 30 units Nb. of units 1 Unit
Pnom total 9.00 kWp Pnom total 8.20 kWac
Pnom ratio 1.098

Results summary
Produced Energy 14.84 MWh/year Specific production 1649 kWh/kWp/year Perf. Ratio PR 79.95 %

Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Near shading definition - Iso-shadings diagram 5
Main results 6

PVsyst TRIAL
Loss diagram 7
Special graphs 8

PVsyst TRIAL
31/05/21 PVsyst Evaluation mode Page 2/8
Project: Projeto_Piloto_2
Variant: New simulation variant

PVsyst V7.2.2
VC0, Simulation date:
31/05/21 11:03
with v7.2.2

General parameters
Grid-Connected System Tables on a building

PV Field Orientation
Orientation Sheds configuration Models used

PVsyst TRIAL
Fixed plane Transposition Perez
Tilt/Azimuth 30 / -20 ° Diffuse Perez, Meteonorm
Circumsolar separate

Horizon Near Shadings User's needs


Free Horizon Detailed electrical calculation Unlimited load (grid)
acc. to module layout

PV Array Characteristics
PV module Inverter
Manufacturer Generic Manufacturer Generic
Model TSM-DD05H-08-(II)-300 Model Primo 8.2-1
(Original PVsyst database) (Original PVsyst database)
Unit Nom. Power 300 Wp Unit Nom. Power 8.20 kWac

PVsyst TRIAL
Number of PV modules
Nominal (STC)
Modules
At operating cond. (50°C)
Pmpp
U mpp
I mpp
30
9.00
2 Strings x 15

8.18 kWp
444 V
18 A
units
kWp
In series
Number of inverters
Total power
Operating voltage
Pnom ratio (DC:AC)
2 * MPPT 50% 1
8.2
80-800
1.10
units
kWac
V

Total PV power Total inverter power


Nominal (STC) 9 kWp Total power 8.2 kWac
Total 30 modules Nb. of inverters 1 Unit
Module area 49.8 m² Pnom ratio 1.10
Cell area 43.6 m²

PVsyst TRIAL
Array Soiling Losses
Loss Fraction

Module Quality Loss


3.0 %
Uc (const)
Uv (wind)
Array losses
Thermal Loss factor
Module temperature according to irradiance

Module mismatch losses


20.0 W/m²K
0.0 W/m²K/m/s
DC wiring losses
Global array res.
Loss Fraction

Strings Mismatch loss


49 mΩ
0.2 % at STC

Loss Fraction -0.8 % Loss Fraction 2.0 % at MPP Loss Fraction 0.1 %

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

PVsyst TRIAL
31/05/21 PVsyst Evaluation mode Page 3/8
Project: Projeto_Piloto_2
Variant: New simulation variant

PVsyst V7.2.2
VC0, Simulation date:
31/05/21 11:03
with v7.2.2

AC wiring losses
Inv. output line up to injection point
Inverter voltage 230 Vac mono
Loss Fraction 1.24 % at STC
Inverter: Primo 8.2-1

PVsyst TRIAL
Wire section (1 Inv.) Copper 1 x 2 x 10 mm²
Wires length 20 m

PVsyst TRIAL

PVsyst TRIAL

PVsyst TRIAL
31/05/21 PVsyst Evaluation mode Page 4/8
Project: Projeto_Piloto_2
Variant: New simulation variant

PVsyst V7.2.2
VC0, Simulation date:
31/05/21 11:03
with v7.2.2

Near shadings parameter


Perspective of the PV-field and surrounding shading scene

PVsyst TRIAL

PVsyst TRIAL Iso-shadings diagram

PVsyst TRIAL

PVsyst TRIAL
31/05/21 PVsyst Evaluation mode Page 5/8
Project: Projeto_Piloto_2
Variant: New simulation variant

PVsyst V7.2.2
VC0, Simulation date:
31/05/21 11:03
with v7.2.2

Main results
System Production
Produced Energy 14.84 MWh/year Specific production 1649 kWh/kWp/year
Performance Ratio PR 79.95 %

PVsyst TRIAL
Normalized productions (per installed kWp) Performance Ratio PR

PVsyst TRIAL
January
GlobHor
kWh/m²
200.8
DiffHor
kWh/m²
84.04
Balances and main results

T_Amb
°C
23.54
GlobInc
kWh/m²
178.2
GlobEff
kWh/m²
165.6
EArray
MWh
1.325
E_Grid
MWh
1.271
PR
ratio
0.793
February 147.1 70.38 24.01 138.4 129.0 1.026 0.983 0.789
March 169.3 75.38 23.48 176.0 165.2 1.310 1.257 0.794
April 151.9 50.28 21.81 178.2 167.9 1.332 1.279 0.797
May 132.4 40.12 18.91 173.9 162.4 1.311 1.259 0.804
June 114.0 38.33 17.91 157.7 146.6 1.202 1.155 0.814
July 133.2 31.52 17.55 184.1 171.4 1.390 1.336 0.806
August 152.6 40.84 19.31 190.4 179.5 1.438 1.380 0.806

PVsyst TRIAL
September 157.4 62.07 20.53 170.9 160.9 1.290 1.238 0.805
October 198.6 67.09 22.54 196.7 184.5 1.465 1.406 0.794
November 175.5 83.35 22.10 157.5 146.2 1.183 1.135 0.801
December 185.8 83.72 23.46 160.7 148.7 1.193 1.144 0.791
Year 1918.6 727.13 21.25 2062.6 1928.0 15.464 14.842 0.800

Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings

PVsyst TRIAL
31/05/21 PVsyst Evaluation mode Page 6/8
Project: Projeto_Piloto_2
Variant: New simulation variant

PVsyst V7.2.2
VC0, Simulation date:
31/05/21 11:03
with v7.2.2

Loss diagram
1919 kWh/m² Global horizontal irradiation
+7.5% Global incident in coll. plane

PVsyst TRIAL
-1.29% Near Shadings: irradiance loss

-2.38% IAM factor on global

-3.00% Soiling loss factor

1928 kWh/m² * 50 m² coll. Effective irradiation on collectors

efficiency at STC = 18.10% PV conversion

17.40 MWh Array nominal energy (at STC effic.)


-0.49% PV loss due to irradiance level

-9.17% PV loss due to temperature

-0.14% Shadings: Electrical Loss detailed module calc.

PVsyst TRIAL
+0.75% Module quality loss

-2.10% Mismatch loss, modules and strings


-0.14% Ohmic wiring loss
15.46 MWh Array virtual energy at MPP

-3.32% Inverter Loss during operation (efficiency)

0.00% Inverter Loss over nominal inv. power


0.00% Inverter Loss due to max. input current
0.00% Inverter Loss over nominal inv. voltage
0.00% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
14.95 MWh Available Energy at Inverter Output

PVsyst TRIAL 14.84 MWh


-0.72% AC ohmic loss
Energy injected into grid

PVsyst TRIAL
31/05/21 PVsyst Evaluation mode Page 7/8
Project: Projeto_Piloto_2
Variant: New simulation variant

PVsyst V7.2.2
VC0, Simulation date:
31/05/21 11:03
with v7.2.2

Special graphs
Daily Input/Output diagram

PVsyst TRIAL

PVsyst TRIAL
System Output Power Distribution

PVsyst TRIAL

PVsyst TRIAL
31/05/21 PVsyst Evaluation mode Page 8/8