Wind Load Calculation
Wind Load Calculation
The design wind loads are calculated according to IS : 875 ( Part 3 ) - 1987
Basic wind speed Vb = 50 m/sec
Probability Factor, k1 = 1 ( Table 1 )
Terrain, height & structure size factor k2 = 1.03 (Height up to 17 m)
Category 3 & Class C
Topography factor k3 = 1 As per Cl 5.3.3.1
For Cladded portion
Design wind speed Vz = (Vb x K1 x K2 x K3 )
(Height up to 10m) = 51.5 m/sec
Design wind Pressure pz = 0.6 x Vz2
(Height up to 17m) = 1.591 kN/m2
Wind Load on Individual Members F = (Cpe-Cpi) x A x pd
Internal Pressure Coefficient Cpi = 0.5 As per Cl 6.2.3.1 IS 875
-0.5
Percentage of openings = 5 to 20% (Assumed)
= 1.2
East & West (X Dir)
Roof
61.59 kN 3m
4
123.17 kN
3m
3
123.17 kN
3m
2
123.17 kN
3m
1
123.17 kN
3m
GF