Mr. C.H.Park / Project Manager 03-May-06

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 30

Approved - GTD

Mr. C.H.Park / Project Manager 17 May 2006

03-May-06
EGP3 Onshore Project Condensate Debutanizer Reboiler Data Sheet
ONS-HHI-GP-DAS-PR-0011

Revision Log
Major Change
Rev. No. Rev. Date Revision Description Revised Page
Description
1A 01/28/04 PROCESS DATA ISSUE
1B 02/16/04 Mech. Issue for review
2 4/8/04 Issued For ITB3
3 05-Aug-05 Issue for Design No Comments
4 21-Nov-05 Issue for Purchase 1, 2, 3, 4, 5 1. Both side process
data changed by
mechanical data
sheets
2. Reboiler Heating
Curve is embedded
3. Exchanger
Geometry
Changed.
4. Page 4 & 5 added.
5 17-Mar-06 Issue for Purchase 1, 2, 3, 4, 5 1. Redesigned with
hot oil system
optimization.
6 03-May-06 Re-issued for Purchase 1 1. Note is added
in flange table.
- - Review notice for
company comments
incorporated.

ONS-HHI-GP-DAS-PR-0011 2-E-5900 Condensate Debutanizer Reboiler_R6


JOB NO. ____ ________ HX ITEM NO. 2-E-5900
INQUIRY/PURCHASE ORDER NO.
SPECIFICATION NO. EGP3-09.00
SHELL AND TUBE HEAT EXCHANGER
REVISION NO. 6 DATE 03-May-06
API: 660 DATA SHEET
BY: ____J.H.Lee _________________________________
SI UNITS

1 Facility Location: Escravos, Nigeria Job No.: 156261 PFD# 10-5029 P&ID# 10-8120
2 Project: Escravos Gas Project – Phase 3 (EGP3) Item/Tag No.: 2-E-5900 No. Req’d: One
3 Client: Chevron Nigeria Ltd. Service: CONDENSATE DEBUTANIZER REBOILER - TRAIN 1
4 Feed Contractor: Parsons E&C Parsons Inquiry/PO No.: Shell & Tube By Co.: *
5 Manufacturer: * Model No.: *
6 Serial No.: *
7 Service Rating (Defines In-Service Inspection Requirements for Refineries)
8 Size1000x3658mm Type AET Horizontal Vertical No. Connected in: Parallel Series
9 Surface/Unit 138.1 m2 Gross Eff Shells/Unit: 1 Surface/Shell 138.1 m2 Gross Eff.
10 PERFORMANCE OF ONE UNIT
11 Fluid Allocation Shell Side Tube Side
12 Fluid Name Hot Oil (Dowtherm Q) Cond. DeC4 Column Bottoms
13 Fluid Quantity—Total kg/ h 1.1X 279895(Note 8) 1.1X 228109
14 Vapor (In/Out) 1.1X 42656( Note 1)
15 Liquid (In/Out) 1.1X 279895 1.1X 279895 1.1X 228109 1.1X 185453
16 Steam (In/Out)
17 Water (In/Out)
18 Noncondensable (In/Out)
19 Temperature (In/Out) ºC 263.0 236.0 189.7 203.5
20 Density (Liquid/Vapor) kg/m3 781.6 802.0 568.8 570.5 31.0
21 Viscosity (Liquid/Vapor) cP 0.2161 0.2462 0.1252 0.1250 0.0111
22 Mol Wt. Vapor (on line 14) 88.81
23 Mol Wt. Noncondensable (on line 18)
24 Specific Heat (L/V) kJ/(kg-C) 2.395 2.3152 2.8528 2.8747 2.4824
25 Thermal Cond. (L/V) W/mK 0.0870 0.0911 0.0569 0.0551 0.0304
26 Latent Heat kJ/kg @ ºC @ 428.11
27 Inlet Pressure: barG bara 7.6 11.3 (NOTE 2)
28 Velocity m/s 0.89 0.84
29 Pressure Drop (Allow/Calc) bar 0.50 0.46 NAT CIRCULATION
2
30 Fouling Resistance—Min. m -ºC/W NOTE 5 NOTE 5
31 Heat Exchanged 1.1x4942.5 kW (Note4) MTD—Corrected 49.9 ºC
32 Transfer Rate: Service 788.65 W/m2-ºC Clean NOTE 5 W/m2-ºC
33 CONSTRUCTION OF ONE SHELL Bundle/Nozzle Orientation Sketch
34 Shell Side Tube Side
35 Design Pressure barg 23.1 (NOTE 9) 20.8 (NOTES 9,13)
36 Design Temperature ºC 340 (NOTE 9) 340 (NOTE 9)
37 MDMT ºC 11.1 11.1
38 No. Passes per Shell 1 1
39 Corrosion Allowance mm 3.0 3.0
40 Connections Size (NPS) In
41 and Rating (ANSI Class) Out See page 4 See page 4
42 [Also see Note 7.] Vent / Drain See attached sketch.
43 NO. DATE REVISION BY APP.
44 6 03-May-06 Re-issued for Purchase JHL KBC
45 5 17-Mar-06 Issued for Purchase B.I.Choi JRP
46 4 21-Nov-05 Issued for Purchase H.J.Kim NWP
47 3 05-Aug-05 Issued for Design H.J.Kim KBC
48 2 4/8/04 Issued For ITB3 CA / JKT JCW

Document Number: ONS-HHI-GP-DAS-PR-0011


P-SHELL & TUBEHE.DOC.REV0 – ISSUED: 03/2002 (BLANK DATA SHTS) Page 1 of 5
CHEVRON NIGERIA LTD. - ESCRAVOS GAS PROJECT (EGP3)
JOB NO. ____ ________ HX ITEM NO. 2-E-5900
INQUIRY/PURCHASE ORDER NO.
SPECIFICATION NO. EGP3-09.00
SHELL AND TUBE HEAT EXCHANGER
REVISION NO. 6 DATE 03-May-06
API: 660 DATA SHEET
BY: ____J.H.Lee _________________________________
SI UNITS

1 Tubes: No.: 500 OD: 25.4 mm Thickness: 2.77 mm Min Avg Length: 3.658 m Pitch: 31.75 mm
2 Type Bare Material A179 Welded Seamless Layout 30° 60° 90° 45°
3 Shell Material: SA516-70 Dia 1000 mm ID OD Shell Cover Material: SA516-70 Integ Rem
4 Channel or Bonnet Material: SA516-70 Channel Cover Material SA516-70
5 Stationary Tubesheet Material: SA350-LF2 Floating Tubesheet Material SA350-LF2
6 Floating Head Cover Material: SA516-70/SA234-WPB Impingement Protection: NOTE 6 Yes No
7 Cross Baffles: Material CS Type HOR. SEGM
8 20.9 % Cut Dia. Area Spacing 235 mm c/c Inlet mm
9 Long Baffles Material Seal Type
10 Tube Supports Material U-Bend Type
11 Bypass Seal: Yes No Tube-Tubesheet Joint Expanded Seal Weld Strength Weld***
12 Expansion Joint: Yes No Material 316L SS Type *
13 Internal (NOTE 10) Average Metal Temperature: Shell 242.0 °C Tubes 215.4 °C
14 ρV2: Inlet Nozzle 4360 Kg/m-s2 Bundle Entrance kg/m-s2 Bundle Exit kg/m-s2
15 Gaskets: Shell Side ** Tube Side ** Floating Head **
16 Code: ASME Stamp: Yes No Nat’l Board Registration: Yes No TEMA Class R
17 Weights: Dry kgs Filled with Water kgs Bundle kgs
18 PMI Yes No
19 Special Services Yes No
20 Applicable Company Specifications See referenced documents below.
21 Insulation Support Rings: Yes No per EGP3-14.00 Insulation Type: (Hot/Cold) Mat’l: Perlite
22 Protective Coating: Manufacturer’s Standard per EGP3-02.04 System: Shell “AE” / Tube “AE”
23 Minimum Thickness Calculation Yes No
24 Threaded Connections Permitted Yes No
25 Continuous Tube Lanes Required Yes No
26 Connections Beveled for Welding Yes No
27 Insulation Thickness Shell 100 mm Channel 70 mm
28 Chemical Cleaning Connections Per Spec Yes No Size, NPS
29 PWHT of Carbon Steel Channels and Bonnets Yes No Per Code & Spec, if req’d by design
30 PWHT for Process Reasons Yes No
31 Special Flatness Requirements for Gasket Contact Services Yes No Per API 660 Table 3
32 Removal of Bonnet or Channel for Shell-Side Hydrostatic Test Yes No
33 Test Rings Yes No
34 Supplemental Requirements 100% X-Ray Yes No Spot X-ray required
35 Type of Insulation Jacketing:
36 Estimated: Total Paint Area: * m2 Total Insulation Area: * m2
37 *** Per ASME Sec. VIII Div. 1 Paragraph UW-20.
38 ** 304L or 316L stainless steel, corrugated metal, graphoil coated, Lamons 360-CMG
39 * Indicates Data to be Provided by Vendor
40 REFERENCED DOCUMENTS
41 DOC. NO. DATE DOCUMENT TITLE
42 Spec. EGP3-09.00 Rev. 0 SHELL & TUBE HEAT EXHANGERS FOR ROUTINE SERVICE
43 (WITH CARBON STEEL THIN & THICK WALLS, SOLID ALLOY AND/OR
44 ALLOY-CLAD CONSTRUCTION)
45 -- -- ALL SPECS. AND DRAWINGS REFERENCED IN EGP3-09.00
46
47
48

Document Number: ONS-HHI-GP-DAS-PR-0011


P-SHELL & TUBEHE.DOC.REV0 – ISSUED: 03/2002 (BLANK DATA SHTS) Page 2 of 5
CHEVRON NIGERIA LTD. - ESCRAVOS GAS PROJECT (EGP3)
JOB NO. ____ ________ HX ITEM NO. 2-E-5900
INQUIRY/PURCHASE ORDER NO.
SPECIFICATION NO. EGP3-09.00
SHELL AND TUBE HEAT EXCHANGER
REVISION NO. 6 DATE 03-May-06
API: 660 DATA SHEET
BY: ____J.H.Lee _________________________________
SI UNITS

ADDITIONAL NOTES/SKETCH

1. The Controlling Case is the Hi AG Rerun Case. The reboiler is designed for 10% excess duty and flow rates.
2. Column Sump Pressure =11.3 bara.
3. Deleted
4. Deleted
5. Reboiler is designed with no fouling factors per CNL directive (EGP3-01-CO-031-PNC-0020, dated 06/27/02).
6. Provide two rows of rods for impingement protection.
7. Provide two 3”-300# RFWN connections in the inlet floating head cover 180° apart for removal of any sand
deposits.
8. Deleted..
9. In addition to the internal and external design pressures specified on the data sheets, exchanger design shall
also be adequate for and Code stamped for 0.5 bar external pressure at 149°C or specified design
temperature, whichever is greater and excluding any corrosion allowance.
10. Provide internal bellows type expansion joint. Expansion joint shall be single ply, designed for a minimum of
5000 cycles and designed in accordance with ASME & EJMA latest editions. Expansion joint shall be
checked for upset conditions and design to be confirmed by EPC contractor.
11. Design wind speed for 3-second gust at 33 ft. height to 40 meters/sec (89.5 mph)
12. Removable insulation inspection ports shall be provided per specification EGP3-14.00.
13. Revised tube side design pressure to 20.8 barg (75% of shell side design pressure) based on increased hot
oil operating pressure and to mitigate the tube rupture case.
14. Deleted.
15. Baffle to shell diametral clearance shall be less than 4.0 mm.
16. Sealing strips shall not extend into the inlet and outlet regions of tube bundle.

Document Number: ONS-HHI-GP-DAS-PR-0011


P-SHELL & TUBEHE.DOC.REV0 – ISSUED: 03/2002 (BLANK DATA SHTS) Page 3 of 5
CHEVRON NIGERIA LTD. - ESCRAVOS GAS PROJECT (EGP3)
JOB NO. ____ ________ HX ITEM NO. 2-E-5900
INQUIRY/PURCHASE ORDER NO.
SPECIFICATION NO. EGP3-09.00
SHELL AND TUBE HEAT EXCHANGER
REVISION NO. 6 DATE 03-May-06
API: 660 DATA SHEET
BY: ____J.H.Lee _________________________________
SI UNITS

SHELL SIDE TUBE SIDE


NOZZLE

Document Number: ONS-HHI-GP-DAS-PR-0011


P-SHELL & TUBEHE.DOC.REV0 – ISSUED: 03/2002 (BLANK DATA SHTS) Page 4 of 5
CHEVRON NIGERIA LTD. - ESCRAVOS GAS PROJECT (EGP3)
JOB NO. ____ ________ HX ITEM NO. 2-E-5900
INQUIRY/PURCHASE ORDER NO.
SPECIFICATION NO. EGP3-09.00
SHELL AND TUBE HEAT EXCHANGER
REVISION NO. 6 DATE 03-May-06
API: 660 DATA SHEET
BY: ____J.H.Lee _________________________________
SI UNITS

Document Number: ONS-HHI-GP-DAS-PR-0011


P-SHELL & TUBEHE.DOC.REV0 – ISSUED: 03/2002 (BLANK DATA SHTS) Page 5 of 5
CHEVRON NIGERIA LTD. - ESCRAVOS GAS PROJECT (EGP3)
EGP3 Project
2005.09.27
By S.J.Bak

2-E-5900
Condensate Debuthanizer Reboiler -Train 1
High AG Rerun case
PERFORMANCE TABLE
Overall Phase Vapour Phase Light Liquid Phase
Temp. Pressure Heat Flow Enthalpy Vapour Mass Flow Density Mass Specific Heat Viscosity Thermal Conductivity Mass Flow Density Mass Specific Heat Viscosity hermal Conductivit Surface Tension
Molecular Molecular
Fraction
(C) (bar) (kW) (kJ/kgmole) (kg/h) Weight (kgmole/m3 (kg/m3) (kJ/kg-C) (cP) (W/m-K) (kg/h) Weight (kgmole/m3 (kg/m3) (kJ/kg-C) (cP) (W/m-K) (dyne/cm)
(Mole)
189.69 11.31 ######### 0.00 0.00 0.00 83.60 0.37 2.4502 0.0109 0.0296 163808.36 109.63 5.19 568.79 2.8528 0.1252 0.0569 6.1255
191.76 11.31 ######### 561.21 0.04 4663.16 84.18 0.36 2.4550 0.0109 0.0297 159145.20 5.14 2.8562 0.1251 0.0572 6.1153
193.83 11.31 ######### 1120.60 0.07 9319.32 84.75 0.36 2.4598 0.0109 0.0298 154489.04 5.10 2.8595 0.1251 0.0571 6.1046
195.90 11.31 ######### 1677.44 0.11 13957.43 85.33 0.36 2.4646 0.0110 0.0299 149850.94 5.06 2.8628 0.1247 0.0559 6.0940
197.97 11.31 ######### 2231.21 0.14 18569.44 85.91 0.36 2.4694 0.0110 0.0301 145238.92 5.01 2.8660 0.1245 0.0529 6.0874
200.04 11.31 ######### 2781.48 0.18 23149.15 86.48 0.36 2.4743 0.0110 0.0302 140659.21 4.97 2.8693 0.1253 0.0538 6.0801
202.11 11.31 ######### 3327.94 0.21 27691.45 87.06 0.36 2.4792 0.0110 0.0303 136116.92 4.93 2.8725 0.1251 0.0546 6.0708
204.18 11.31 ######### 3870.29 0.25 32192.09 87.64 0.35 2.4840 0.0111 0.0304 131616.28 4.89 2.8757 0.1249 0.0554 6.0597
206.25 11.31 ######### 4408.33 0.28 36647.52 88.22 0.35 2.4890 0.0111 0.0306 127160.84 4.84 2.8789 0.1247 0.0561 6.0470
208.32 11.31 ######### 4941.87 0.31 41054.89 88.81 0.35 31.13 2.4939 0.0111 0.0307 122753.47 118.95 4.80 571.09 2.8822 0.1244 0.0568 6.0328

PERFORMANCE PLOT

Critical Properties
True Tc (C) 316.01
Pseudo Tc (C) 287.02
True Pc (bar) 37.10
Pseudo Pc (bar) 29.97
True Vc (m3/kgmole) 0.51
Pseudo Vc (m3/kgmole) 0.41
True Zc 0.39
Pseudo Zc 0.26
EGP3 Project
2005.09.27
By S.J.Bak

2-E-5900
Condensate Debuthanizer Reboiler -Train 1
High AG Rerun case (Inlet Pressure + 2.5 psi)
PERFORMANCE TABLE
Overall Phase Vapour Phase Light Liquid Phase
Temp. Pressure Heat Flow Enthalpy Vapour Mass Flow Density ss Specific H Viscosity rmal Conduct Mass Flow Density ss Specific H Viscosity ermal Conductivurface Tensio
Molecular Molecular
Fraction
(C) (bar) (kW) (kJ/kgmole) (kg/h) Weight (kgmole/m3) (kg/m3) (kJ/kg-C) (cP) (W/m-K) (kg/h) Weight (kgmole/m3) (kg/m3) (kJ/kg-C) (cP) (W/m-K) (dyne/cm)
(Mole)
189.70 11.47 0.00 -193099.87 0.00 - - - - - - - 289404.00 109.63 5.19 568.78 2.8523 0.1252 0.0569 6.1250
190.91 11.47 330.31 -192649.41 0.00 824.44 83.75 0.37 - 2.4570 0.0109 0.0297 288579.56 5.17 2.8603 0.1242 0.0564 6.0577
192.13 11.47 911.97 -191856.19 0.03 5672.67 84.09 0.37 - 2.4598 0.0109 0.0298 283731.33 5.15 2.8622 0.1242 0.0565 6.0517
193.34 11.47 1492.65 -191064.30 0.05 10518.62 84.42 0.37 2.4626 0.0109 0.0298 278885.38 5.12 2.8642 0.1242 0.0565 6.0456
194.55 11.47 2072.04 -190274.17 0.07 15357.66 84.76 0.37 2.4654 0.0110 0.0299 274046.34 5.10 2.8661 0.1241 0.0563 6.0394
195.77 11.47 2649.91 -189486.11 0.09 20186.08 85.10 0.37 2.4682 0.0110 0.0300 269217.92 5.07 2.8680 0.1239 0.0555 6.0334
196.98 11.47 3226.05 -188700.42 0.11 25000.80 85.44 0.37 2.4710 0.0110 0.0300 264403.20 5.05 2.8699 0.1235 0.0518 6.0293
198.20 11.47 3800.29 -187917.31 0.13 29799.20 85.77 0.36 2.4738 0.0110 0.0301 259604.80 5.02 2.8718 0.1236 0.0523 6.0261
199.41 11.47 4372.48 -187136.99 0.15 34579.02 86.11 0.36 2.4766 0.0110 0.0302 254824.98 4.99 2.8737 0.1240 0.0529 6.0221
200.62 11.47 4942.50 -186359.65 0.17 39338.25 86.45 0.36 31.37 2.4795 0.0110 0.0303 250065.75 114.46 4.97 568.79 2.8756 0.1244 0.0534 6.0175

PERFORMANCE PLOT

Critical Properties
True Tc (C) 316.01
Pseudo Tc (C) 287.03
True Pc (bar) 37.09
Pseudo Pc (bar) 29.97
True Vc (m3/kgmole) 0.51
Pseudo Vc (m3/kgmole) 0.41
True Zc 0.39
Pseudo Zc 0.26
EGP3 Project
2005.09.27
By S.J.Bak

2-E-5900
Condensate Debuthanizer Reboiler -Train 1
High AG Rerun case (Inlet Pressure + 5 psi)
PERFORMANCE TABLE
Overall Phase Vapour Phase Light Liquid Phase
Temp. Pressure Heat Flow Enthalpy Vapour Mass Flow Density ss Specific H Viscosity rmal Conduct Mass Flow Density ss Specific H Viscosity hermal Conductiviturface Tensio
Molecular Molecular
Fraction
(C) (bar) (kW) (kJ/kgmole) (kg/h) Weight (kgmole/m3) (kg/m3) (kJ/kg-C) (cP) (W/m-K) (kg/h) Weight (kgmole/m3) (kg/m3) (kJ/kg-C) (cP) (W/m-K) (dyne/cm)
(Mole)
189.69 11.64 0.00 -193102.31 0.00 - - - - - - - 289404.00 109.63 5.19 568.79 2.8517 0.1235 0.0529 5.9538
190.96 11.64 292.49 -192703.45 0.00 - - - - - - - 289404.00 109.63 5.17 2.8613 0.1240 0.0563 <empty>
192.23 11.64 707.07 -192138.08 0.01 1950.53 83.91 0.38 2.4641 0.0110 0.0298 287453.47 5.15 2.8681 0.1233 0.0559 5.9880
193.51 11.64 1317.09 -191306.18 0.03 7053.99 84.27 0.38 2.4671 0.0110 0.0299 282350.01 5.13 2.8702 0.1232 0.0558 5.9817
194.78 11.64 1925.91 -190475.94 0.05 12153.03 84.62 0.37 2.4700 0.0110 0.0300 277250.97 5.10 2.8722 0.1232 0.0555 5.9754
196.06 11.64 2533.19 -189647.77 0.08 17242.73 84.98 0.37 2.4729 0.0110 0.0300 272161.27 5.07 2.8742 0.1228 0.0543 5.9694
197.33 11.64 3138.70 -188822.04 0.10 22319.13 85.33 0.37 2.4758 0.0110 0.0301 267084.87 5.05 2.8762 0.1226 0.0512 5.9660
198.60 11.64 3742.20 -187999.04 0.12 27378.94 85.69 0.37 2.4788 0.0110 0.0302 262025.06 5.02 2.8782 0.1228 0.0518 5.9627
199.88 11.64 4343.52 -187179.02 0.14 32419.34 86.04 0.37 2.4817 0.0111 0.0303 256984.66 4.99 2.8802 0.1235 0.0524 5.9586
201.15 11.64 4942.50 -186362.18 0.16 37437.92 86.40 0.37 31.87 2.4847 0.0111 0.0304 251966.08 80.56 4.97 567.36 2.8821 0.1235 0.0529 5.9538

PERFORMANCE PLOT

Critical Properties
True Tc (C) 316.01
Pseudo Tc (C) 287.02
True Pc (bar) 37.10
Pseudo Pc (bar) 29.97
True Vc (m3/kgmole) 0.51
0.18 Pseudo Vc (m3/kgmole) 0.41
True Zc 0.39
Pseudo Zc 0.26
EGP3 Project
2005.09.27
By S.J.Bak

2-E-5900
Condensate Debuthanizer Reboiler -Train 1
High AG Rerun case (Inlet Pressure + 10 psi)
PERFORMANCE TABLE
Overall Phase Vapour Phase Light Liquid Phase
Temp. Pressure Heat Flow Enthalpy Vapour Mass Flow Density ss Specific H Viscosity rmal Conduct Mass Flow Density ss Specific H Viscosity Thermal Conductiviturface Tensio
Molecular Molecular
Fraction
(C) (bar) (kW) (kJ/kgmole) (kg/h) Weight (kgmole/m3) (kg/m3) (kJ/kg-C) (cP) (W/m-K) (kg/h) Weight (kgmole/m3) (kg/m3) (kJ/kg-C) (cP) (W/m-K) (dyne/cm)
(Mole)
189.69 12.00 0.00 -193104.12 0.00 - - - - - - - 289404 109.63 5.19 568.79 2.8506 0.1252 0.0569 6.1255
191.08 12.00 320.84 -192666.59 0.00 - - - - - - - 289404 109.63 5.17 - 2.8611 0.1239 0.0562 <empty>
192.48 12.00 642.86 -192227.44 0.00 - - - - - - - 289404.00 109.63 5.16 2.8717 0.1226 0.0554 <empty>
193.88 12.00 966.09 -191786.65 0.00 - - - - - - - 289404.00 109.63 5.14 2.8825 0.1214 0.0544 <empty>
195.28 12.00 1622.23 -190891.86 0.02 5419.82 84.34 0.39 2.4798 0.0111 0.0301 283984.18 5.11 2.8851 0.1212 0.0538 5.8424
196.67 12.00 2290.55 -189980.47 0.05 11056.41 84.73 0.39 2.4830 0.0111 0.0302 278347.59 5.08 2.8873 0.1206 0.0494 5.8373
198.07 12.00 2957.05 -189071.56 0.07 16682.04 85.12 0.39 2.4862 0.0111 0.0303 272721.96 5.05 2.8895 0.1208 0.0501 5.8348
199.47 12.00 3621.39 -188165.60 0.10 22291.44 85.51 0.38 2.4894 0.0111 0.0304 267112.56 5.02 2.8917 0.1212 0.0507 5.8312
200.87 12.00 4283.28 -187262.97 0.12 27880.29 85.90 0.38 2.4926 0.0111 0.0305 261523.71 4.99 2.8938 0.1216 0.0513 5.8268
202.26 12.00 4942.50 -186363.99 0.15 33444.97 86.29 0.38 32.93 2.4958 0.0111 0.0305 255959.03 113.65 4.97 564.34 2.8960 0.1215 0.0519 5.8214

PERFORMANCE PLOT

Critical Properties
True Tc (C) 316.01
Pseudo Tc (C) 287.02
True Pc (bar) 37.10
Pseudo Pc (bar) 29.97
True Vc (m3/kgmole) 0.51
Pseudo Vc (m3/kgmole) 0.41
True Zc 0.39
Pseudo Zc 0.26
W:₩HEC₩050817_EGP3₩Design₩OtherOperSimulation₩2E-5900.lis

HTRI AXIAL FLOW REBOILER PROGRAM RTF-2 MOD 7.21-1.30 HTRI VERSION PAGE NO- 1
RATING--TUBESIDE BOILING VERTICAL THERMOSIPHON REBOILER COCURRENT SENSIBLE LIQUID
PROBLEM DESCRIPTION-2-E-5900 : CONDENSATE DEBUTANIZE CASE-HiAGX1.1
---Input Data Reprint------------------------------------------------SI UNITS------------------------------------------
*CARD 1* CONTROL INFORMATION *CARD 2* BOILING FLUID PROCESS *CARD 3* HEATING MEDIUM, FOULING
01 CIN INPUT UNITS CODE 1. 01 QT HEAT DUTY 5436.75 01 HMC HEATING MED CODE 1.
02 COUT OUTPUT UNITS CODE 1. 02 PX FEED PRESSURE 1131.00 02 SAC SENS HEAT CALC 1.
03 UTYPE REBOILER TYPE 0. 03 PDISC REB DISCHARGE PR 0.00 03 THIN HEAT MED IN TEMP 263.00
04 UORIN ORIENTATION ANGLE 0.00 04 WMAIN MAIN FLOW RATE 0.00 04 THOUT HEAT MED OUT TEMP 236.00
05 BOILC TUBE OR SHELL 0. 05 TBF MAIN INLET TEMP 189.69 05 WH HEAT MED FLO RATE 0.00
06 SUVAP SUPPRESS VAPORIZE 0. 06 YMAIN MAIN WT FR VAPOR 0.000 06 DPMXS MAX ALLOWABLE DP 50.00
07 CDTLM TEMP LIMIT CODE 0. 07 BRCHC BRNCH STREAM CODE 0. 07 DPNH DP ADJUSTMENT CODE 0.
08 DQMAX MAX HEAT FLUX 0.00000 08 WBRCH BRNCH FLOW RATE 0.00 08 PHIN HEAT MED IN PRES 1090.00
09 YMAX MAX WT FR VAPORIZED 0.000 09 TBRCH BRNCH INLET TEMP 0.00 09 HMFC HEAT MED FLOW CODE 1.
10 TWMAX MAX TUB WALL TEMP 0.00 10 YBRCH BRNCH WT FR VAPOR 0.000 10 HH HEAT MED HT COEFF 0.00
11 CASE RATING OR DESIGN 0. 11 FLCC FLOW CALC CODE 0. 11 RFT BOIL FOUL FACTOR 0.00000
12 CMETH CALC METHOD CODE 0. 12 HD LIQ DRIVING HEAD 4.028 12 RFS HEAT FOUL FACTOR 0.00000
13 SBLZ SUBCOOL BOIL 0. 13 DPMAX MAX TUBE DP 0.00 13 DUM31 WT FR NOT CONDENS 0.000
14 PRINC PRINTOUT CODE 0. 14 VLMAX MAX TUBE VELOCITY 0.00
15 CMONI MONITOR CODE 0. 15 SGWF SPARGE GAS WT FR 0.000
16 CINST INSTABILITY CHECK 1. 16 SGMW SPARGE GAS MW 0.00
17 EXTR1 PHY PROP BASED H 0.
18 EXTR2 SUP FILM BOIL CODE 0.
*CARD 4* BUNDLE GEOMETRY *CARD 5* BOILING SIDE PIPING *CARD 6* TUBE INFORMATION
01 DSMAX SHELL ID 1000.000 01 SLIN TOT LEN IN PIPE 30000.00 01 TL TUBE LENGTH 3.658
02 XM SHELLS IN PARALLEL 1. 02 SLOUT TOT LEN OUT PIPE 5000.00 02 DTO TUBE OD 25.4000
03 XNTT1 NO TUBES/SHELL 500. 03 XLVO VERT LEN OUT PIPE 0.00 03 TWTH TUBE WALL THICK 3.0450
04 BUNT BUNDLE TYPE 3. 04 PRIN FR DP INLET PIPE 0.0000 04 PT TUBE PITCH 31.7500
05 BSL BAFFLE SPACING 235.000 05 ARIN INLET AREA RATIO 0.000 05 TLA TUBE LAYOUT ANGLE 45.
06 BCS BAFFLE CUT 20.90 06 DKLIN INLET VELOC-HEAD 0.00 06 XKKW TUBE THERMAL COND 47.500
07 BDRMX MAX (BSL/DS) 0.000 07 PROUT FR DP OUTLET PIPE 0.000 07 XKCT TUBE TYPE 0.
08 TSTH TUBESHEET THICK 98.0000 08 AROUT OUTLET AREA RATIO 0.000 08 XNF NO OF FINS/LENGTH 0.000
09 STRTF NO OF SEAL STRIPS 5. 09 DKLOT OUTLET VELOC-HEAD 0.00 09 FH FIN HEIGHT 0.0000
10 DINP INLET PIPE ID 288.9000 10 DFR FIN ROOT DIAMETER 0.0000
*CARD 7* 11 DOUTP OUTLET PIPE ID 482.6000 11 XLF FIN THICKNESS 0.0000
01 HMXNC NO OF HEAT MED COMP 1. 12 PRVAL FR DP INLET VALVE 0.000 12 FARP SURF AREA/LENGTH 0.000
02 BMXNC NO OF BOIL FLU COMP 1. 13 DUM51 FEED TEMP ADJUST 0. 13 TRTH THICKNESS UNDER FIN 0.0000
03 CD10 CARD 10 USE CODE 0. 14 DUM52 EXIT HEADER HIGHT 1700.000
**CARDS 7,8,9** OPTIONAL BOILING DATA AND CONTROL FOR PHYSICAL PROPERTY SETS
*CARD 9* VAPOR WT FR Y 0.000 0.070 0.120 0.300 1.000
06 REFPN REFERENCE PRESS 0.00
07 CNBM DELTA T COEFF 0.00 PVRF 1131.00 T 189.69 194.79 198.46 212.10 265.66
08 CNBE DELTA T EXPONENT 0.00 PVRF 1164.00 T 191.75 196.81 200.46 213.66 265.70
09 FS SURFACE FACTOR 0.00 LIQUID H EY 0.00 0.00 0.00 0.00 0.00
VAPOR H EY 0.00 0.00 0.00 0.00 0.00
VAPOR MOL WT WY 0.00 0.00 0.00 0.00 0.00
*CARD 10* OPTIONAL INCREMENTATION, CONVERGENCY TOLERANCES, AND VIBRATION ANALYSIS
01 XN 2-PHASE INCREMENTS 0. 07 SELCC VIBRATION CODE 0. 13 SELCV6 HEAT CAPACITY RATIO 0.00
02 XLIQ LIQ ZONE LENGTH 0.000 08 SELCV1 AXIAL STRESS LOAD 0. 14 SELCV7 TUBE MATERIAL CODE 0.
03 TOL1 BOIL SIDE LIQ ZONE 0.00 09 SELCV2 ADDED MASS FACTOR 0. 15 SELCV8 ALLOW STRESS 0.
04 TOL2 BOIL SIDE 2-PHASE 0.00 10 SELCV3 SUP PLATE/BAF SPACE 0. 16 SELCV9 TUB ELAST MODULUS 0.00
05 TOL3 VAPOR FR 2-PHASE 0.00 11 SELCV4 VIB LOG DECREMENT 0.00000 17 SELCV10 TUBE DENSITY 0.00
06 TOL4 TOTAL REBOILER DP 0.00 12 SELCV5 STABILITY CONSTANT 0.00000 18 DUM47 NTIW CODE 0.
------------------------------------------------------------------------------------------------------------------------

1/14
W:₩HEC₩050817_EGP3₩Design₩OtherOperSimulation₩2E-5900.lis

HTRI AXIAL FLOW REBOILER PROGRAM RTF-2 MOD 7.21-1.30 HTRI VERSION PAGE NO- 2
RATING--TUBESIDE BOILING VERTICAL THERMOSIPHON REBOILER COCURRENT SENSIBLE LIQUID
PROBLEM DESCRIPTION-2-E-5900 : CONDENSATE DEBUTANIZE CASE-HiAGX1.1
---Input Data Reprint------------------------------------------------SI UNITS------------------------------------------
**HEATING MEDIUM (HOT OIL ) PHYSICAL PROPERTIES** **BOILING FLUID (BTMS ) PHYSICAL PROPERTIES**
COMPONENT 1
COMPONENT 1
NAME HC
NAME HOT OIL
*CARD 11* *CARD 15*
03 BMMN 1.0000
03 HMMN 1.0000
04 BMBR 0.0000
04 APCH 0.
05 TBN 0.00
05 APIH 0.00
06 TRFB 0.00
06 AMWH 0.00
07 TRFB 0.00
07 HCFH 0.00
08 PV 0.00
08 SKIPH 0.
09 PV 0.00
10 CK 0.000
11 CK 0.000
12 VLA 0.00
13 VLA 0.00
14 BRF 75.97
*CARD 16*
02 APCB 0.
03 APIB 0.00
04 AMWSB 0.00
05 HCFB 0.00
06 SKIPB 0.
------------------------------------------------------------------------------------------------------------------------
**HEATING MEDIUM (HOT OIL ) PHYSICAL PROPERTIES**
COMPONENT 1
NAME HOT OIL
*CARD 12*
02 TRTH 280.00 200.00
04 RHOLH 768.80 829.30
06 XMULH 0.2000 0.3100
08 XKKLH 0.0843 0.0967
10 CPLH 2.444 2.208
12 ENTLH 0.00 0.00
*CARD 13*
02 XMUVH 0.0000 0.0000
04 XKKVH 0.0000 0.0000
06 CPVH 0.0000 0.0000
08 ENTVH 0.00 0.00
10 RHOVH 0.0000
11 AMWSH 0.00
12 PCH 0.00
13 TCH 0.00
*CARD 14*
02 XLAMH 0.00 0.00
04 SIGMH 0.00 0.00
06 DIFH 0.00 0.00
------------------------------------------------------------------------------------------------------------------------

2/14
W:₩HEC₩050817_EGP3₩Design₩OtherOperSimulation₩2E-5900.lis

HTRI AXIAL FLOW REBOILER PROGRAM RTF-2 MOD 7.21-1.30 HTRI VERSION PAGE NO- 3
RATING--TUBESIDE BOILING VERTICAL THERMOSIPHON REBOILER COCURRENT SENSIBLE LIQUID
PROBLEM DESCRIPTION-2-E-5900 : CONDENSATE DEBUTANIZE CASE-HiAGX1.1
---Input Data Reprint------------------------------------------------SI UNITS------------------------------------------
**BOILING FLUID (BTMS ) PHYSICAL PROPERTIES**
COMPONENT 1
NAME HC
*CARD 17*
02 TRFBA 189.69 208.32
04 RHOLB 568.79 571.09
06 XMULB 0.1252 0.1244
08 XKKLB 0.0569 0.0568
10 CPLB 2.853 2.882
12 ENTLB 0.00 0.00
*CARD 18*
02 XMUVB 0.0109 0.0111
04 XKKVB 0.0296 0.0307
06 CPVB 2.4502 2.4939
08 ENTVB 0.00 0.00
10 RHOVB 30.9500
11 AMWSB 87.06
12 PCB 2997.00
13 TCB 287.02
*CARD 19*
02 XLAMB 223.85 223.85
04 SIGMB 6.13 6.03
06 DIFB 0.00 0.00
------------------------------------------------------------------------------------------------------------------------

3/14
W:₩HEC₩050817_EGP3₩Design₩OtherOperSimulation₩2E-5900.lis

HTRI AXIAL FLOW REBOILER PROGRAM RTF-2 MOD 7.21-1.30 HTRI VERSION PAGE NO- 4
RATING--TUBESIDE BOILING VERTICAL THERMOSIPHON REBOILER COCURRENT SENSIBLE LIQUID
PROBLEM DESCRIPTION-2-E-5900 : CONDENSATE DEBUTANIZE CASE-HiAGX1.1 FLOW=0 DT-ADJ=0 DP-ADJ=0
---Final Results-----------------------------------------------------SI UNITS------------------------------------------
**** PROCESS DATA **** COLD TUBESIDE HOT SHELLSIDE **** SHELLSIDE PERFORMANCE ****
01 FLUID NAME BTMS HOT OIL 01 NOM VEL, X-FLOW/WINDOW 1.15/ 1.11
02 FLUID CONDITION BOIL. LIQUID SENS. LIQUID 02 FILM COEF, X-FLOW/WINDOW 2917.1/ 1690.6
03 TOTAL REBOILER FLOW (KG/S) 69.700 86.966* 03 FLOW FRACTIONS FOR HEAT TRANSFER= 0.545
04 BRANCH STREAM RATE (KG/S) 0.000 04 A=0.224 B=0.396 C=0.204 E=0.176
FEED / EXIT /DISCHRG INLET / OUTLET
05 WEIGHT FRACT VAPOR (--) 0.000 / 0.185 / 0.187 0.000 / 0.000 **** SHELLSIDE HEAT TRANSFER CORRECTIONS ****
06 TEMPERATURE (DEG C) 189.7 / 203.6 / 203.5 263.0 / 236.0 STDEL BETA GAMMA END FIN
07 PRESSURE (KPA) 1131.00 /1135.69 /1131.00 1090.00 /1043.70 05 1.000 0.905 1.000 1.000 0.000
**** PRESSURE DROPS **** (PERCENT OF TOTAL)
08 PRESSURE DROP, TOTAL/ALLOW (KPA) 22.30 / 22.47 46.30 / 50.00 CROSS WINDOW ENDS
09 LIQUID STATIC HEAD (M) 4.03 06 68.37 18.74 12.89
10 DESIGN VELOCITY (M/S) 0.84 0.89 NUCLEATE BOILING ****** FLOW REGIME ******
11 FILM COEF (OUTER A) (W/M2 C) 1310.53 2368.82 METHOD BEGIN MIDDLE END
12 FOULING RESISTANCE (M2 C/W) 0.000000 0.000000 07 REDUCED PROP SLUG SLUG SLUG
**** H.T. PARAMETERS **** SHELL TUBE
**** REBOILER PERFORMANCE CRITERIA **** 08 WALL CORRECTION 0.978
13 AVERAGE OVERALL HEAT TRANSFER COEF (W/M2 C) 788.65 09 MIDPOINT REYNOLDS NO 103976
14 HEAT DUTY, REQUIRED OR SPECIFIED (KW) 5436.75 10
15 TRUE MEAN TEMPERATURE DIFFERENCE (DEG C) 49.91 11
16 SPECIFIED BOILING RANGE (DEG C) 75.97 12
**** THERMAL RESISTANCES **** (PCT OVERALL)
17 HEAT FLUX, DESIGN/MAXIMUM (W/M2) 40018.23/ 62424.68 SHELL TUBE FOULING METAL
18 VAPOR RATE, GENERATED/TOTAL (KG/S) 13.01/ 13.01 13 33.54 60.63 0.00 5.824
19 MAX WETWALL SUPERHEAT (CONDENSING) (DEG C) 0.00 14 DIFFERENTIAL RESISTANCE 0.000001
20 TEMP DIFF FOR FILM BOIL, ONSET/COMP (DEG C) 44.65/ 129.42 15 TOTAL FOULING RESISTANCE 0.000000
**** SHELL CONSTRUCTION INFORMATION ****
21 SHELL TYPE E REAR HEAD PTFH SHELL ID (MM) 1000.000
22 SHELLS PARALLEL 1 TOTAL AREA (M2/SHELL) 138
23 PASSES SHELL 1 TUBE 1 - - - - - - - NO PROGRAM MESSAGES - - - - - -
24 SHELL ORIENTATION ANGLE 0 (DEGREES FROM VERTICAL)
25 PAIRS OF SEALING DEVICES 5
**** BAFFLE INFORMATION ****
26 BAFFLE TYPE SEGMENTAL BAFFLE CUT (PCT DIA) 20.90
27 CROSSPASSES 15 NO. (PCT AREA) (MM TO C.L.)
28 CENTRAL SPACING (MM) 235.000 1 18.595 291.000 **** BOILING SIDE PIPING DATA **** INLET OUTLET
29 INLET SPACING (MM) 235.000 16 DESIGN INSIDE DIAMETER (MM) 288.90 482.60
30 OUTLET SPACING (MM) 235.000 17 TOTAL LENGTH (MM)30000.00 5000.00
31 BAFFLE THICKNESS (MM) 6.808 18 VERTICAL HEIGHT (MM) 0.00
19 STATIC PRESSURE DROP (KPA) 2.70
**** TUBE INFORMATION **** 20 FRICTIONAL PRESSURE DROP (KPA) 1.83
32 TUBE TYPE PLAIN TUBECOUNT PER SHELL 500 21 TOTAL PIPE PRESSURE DROP (KPA) 3.68 4.53
33 OVERALL LENGTH (M) 3.658 22 VALVE PRESSURE DROP (KPA) 0.00 0.00
34 OUTSIDE DIAMETER (MM) 25.4000
35 TOTAL TUBSHEET THICK (MM)196.0 INSIDE DIAMETER (MM) 19.3100 **** DIAMETRAL CLEARANCES (MM) ****
36 AREA RATIO (OUT/IN) 1.315 PITCH (MM)31.7500 RATIO 1.250 BAFFLE-TO-SHELL BUNDLE-TO-SHELL TUBE-TO-BAFFLEHOLE
37 FIN EFFICIENCY 0.000 LAYOUT ANGLE (DEGREES) 45 23 5.6455 180.2912 0.6553
------------------------------------------------------------------------------------------------------------------------

HTRI AXIAL FLOW REBOILER PROGRAM RTF-2 MOD 7.21-1.30 HTRI VERSION PAGE NO- 5
RATING--TUBESIDE BOILING VERTICAL THERMOSIPHON REBOILER COCURRENT SENSIBLE LIQUID
PROBLEM DESCRIPTION-2-E-5900 : CONDENSATE DEBUTANIZE CASE-HiAGX1.1 FLOW=0 DT-ADJ=0 DP-ADJ=0
---Warning/Instability Messages--------------------------------------SI UNITS------------------------------------------
--------------------- STABILITY ANALYSIS MESSAGES ----------------------

STABLE SYSTEM--NO STABILITY THRESHOLD ENCOUNTERED


------------------------------------------------------------------------

4/14
W:₩HEC₩050817_EGP3₩Design₩OtherOperSimulation₩2E-5900.lis

HTRI AXIAL FLOW REBOILER PROGRAM RTF-2 MOD 7.21-1.30 HTRI VERSION PAGE NO- 6
RATING--TUBESIDE BOILING VERTICAL THERMOSIPHON REBOILER COCURRENT SENSIBLE LIQUID
PROBLEM DESCRIPTION-2-E-5900 : CONDENSATE DEBUTANIZE CASE-HiAGX1.1 FLOW=0 DT-ADJ=0 DP-ADJ=0
---Supplementary Results---------------------------------------------SI UNITS------------------------------------------
LIQUID ZONE TWO-PHASE ZONE COLUMN
----------- -------------------------------------------------- REBOILER ENTRANCE/
INCREMENT 1 2 3 4 5 6 EXIT DISCHARGE
CONDITION
01 LENGTH (M) 0.138 0.665
02 WT FR VAPORIZED (--) 0.059 0.099 0.131 0.160 0.185 0.185 0.187
03 BOILING SIDE COEF (W/M2 C) 1855.15 2158.08 1650.34 1573.49 1578.34 1631.62
04 CONVECTIVE (W/M2 C) 1061.99 681.76 1057.57 1367.34 1630.69 1872.66
05 NUCLEATE BOILING (W/M2 C) 793.16 1683.14 976.79 567.12 338.08 202.89
06 VAPOR PHASE (W/M2 C) 24676.37 8742.81 8432.39 7958.82 7628.58
07 HEATING SIDE COEF (W/M2 C) 2368.81 2368.82 2368.82 2368.82 2368.82 2368.82
08 OVERALL U(OUTER A) (W/M2 C) 830.23 905.01 773.71 751.08 752.54 768.27
09 BOIL SIDE BULK TEMP (DEG C) 191.35 192.80 196.22 198.75 200.90 202.75 203.63 203.49
10 HEAT SIDE BULK TEMP (DEG C) 262.15 258.25 251.53 246.36 241.97 238.15
11 BOIL SIDE WALL TEMP (DEG C) 233.03 229.09 230.12 228.39 226.49 224.51
12 BOIL SIDE DELTA T (DEG C) 41.68 36.29 33.90 29.64 25.59 21.75
13 BOIL SIDE PRESSURE (KPA) 1148.41 1145.42 1142.91 1140.61 1138.35 1135.69 1135.69 1131.00
14 BOILING FLOW REGIME SLUG SLUG SLUG SLUG SLUG
**** PHYSICAL PROPERTIES **** BOILING FLUID HEATING MEDIUM
(AT EXIT CONDITION) (EXIT FOR CONDENSING, AVG FOR SENSIBLE)
---------------------------- ----------------------------------------
LIQUID VAPOR LIQUID VAPOR
25 DENSITY (KG/M3) 570.513 30.950 791.866 0.000
26 VISCOSITY (MPA S) 0.12408 0.01105 0.23198 0.00000
27 THERMAL CONDUCTIVITY (W/M C) 0.0568 0.0304 0.0890 0.0000
28 HEAT CAPACITY (KJ/KG C) 2.875 2.483 2.354 0.000
29 ENTHALPY (IF SPECIFIED) (KJ/KG) 0.000 0.000 0.000 0.000
30 AVG MOLECULAR WEIGHT (KG/MOL) 87.06 100.00
31 CRITICAL TEMPERATURE * (DEG C) 287.01 0.00
32 CRITICAL PRESSURE * (KPA) 2997.00 0.00
33 LATENT HEAT * (KJ/KG) 223.85 0.00
34 SURFACE TENSION * (MN/M) 6.06 0.00
35 TEMPERATURE RANGE * (DEG C) 189.68 TO 208.31 199.99 TO 279.99
* WITHOUT INERT GAS, IF INERT GAS IS ADDED TO THE BOILING FLUID
------------------------------------------------------------------------------------------------------------------------

5/14
W:₩HEC₩050817_EGP3₩Design₩OtherOperSimulation₩2E-5900.lis

HTRI AXIAL FLOW REBOILER PROGRAM RTF-2 MOD 7.21-1.30 HTRI VERSION PAGE NO- 11
RATING--TUBESIDE BOILING VERTICAL THERMOSIPHON REBOILER COCURRENT SENSIBLE LIQUID
PROBLEM DESCRIPTION-2-E-5900 : CONDENSATE DEBUTANIZE CASE-LoAGX1.1 FLOW=0 DT-ADJ=0 DP-ADJ=0
---Final Results-----------------------------------------------------SI UNITS------------------------------------------
**** PROCESS DATA **** COLD TUBESIDE HOT SHELLSIDE **** SHELLSIDE PERFORMANCE ****
01 FLUID NAME BTMS HOT OIL 01 NOM VEL, X-FLOW/WINDOW 0.19/ 0.18
02 FLUID CONDITION BOIL. LIQUID SENS. LIQUID 02 FILM COEF, X-FLOW/WINDOW 969.6/ 561.5
03 TOTAL REBOILER FLOW (KG/S) 64.398 14.381* 03 FLOW FRACTIONS FOR HEAT TRANSFER= 0.532
04 BRANCH STREAM RATE (KG/S) 0.000 04 A=0.223 B=0.382 C=0.208 E=0.187
FEED / EXIT /DISCHRG INLET / OUTLET
05 WEIGHT FRACT VAPOR (--) 0.000 / 0.078 / 0.080 0.000 / 0.000 **** SHELLSIDE HEAT TRANSFER CORRECTIONS ****
06 TEMPERATURE (DEG C) 194.2 / 200.2 / 200.0 274.6 / 209.4 STDEL BETA GAMMA END FIN
07 PRESSURE (KPA) 1131.00 /1136.10 /1131.00 1090.00 /1088.55 05 1.000 0.905 1.000 1.000 0.000
**** PRESSURE DROPS **** (PERCENT OF TOTAL)
08 PRESSURE DROP, TOTAL/ALLOW (KPA) 22.52 / 22.74 1.45 / 50.00 CROSS WINDOW ENDS
09 LIQUID STATIC HEAD (M) 4.03 06 70.24 16.37 13.38
10 DESIGN VELOCITY (M/S) 0.76 0.14 NUCLEATE BOILING ****** FLOW REGIME ******
11 FILM COEF (OUTER A) (W/M2 C) 1141.13 787.31 METHOD BEGIN MIDDLE END
12 FOULING RESISTANCE (M2 C/W) 0.000000 0.000000 07 REDUCED PROP BUBBLE SLUG SLUG
**** H.T. PARAMETERS **** SHELL TUBE
**** REBOILER PERFORMANCE CRITERIA **** 08 WALL CORRECTION 0.973
13 AVERAGE OVERALL HEAT TRANSFER COEF (W/M2 C) 442.52 09 MIDPOINT REYNOLDS NO 16415
14 HEAT DUTY, REQUIRED OR SPECIFIED (KW) 2137.30 10
15 TRUE MEAN TEMPERATURE DIFFERENCE (DEG C) 34.97 11
16 SPECIFIED BOILING RANGE (DEG C) 96.04 12
**** THERMAL RESISTANCES **** (PCT OVERALL)
17 HEAT FLUX, DESIGN/MAXIMUM (W/M2) 15832.10/ 62412.57 SHELL TUBE FOULING METAL
18 VAPOR RATE, GENERATED/TOTAL (KG/S) 5.18/ 5.18 13 57.22 39.48 0.00 3.302
19 MAX WETWALL SUPERHEAT (CONDENSING) (DEG C) 0.00 14 DIFFERENTIAL RESISTANCE 0.000001
20 TEMP DIFF FOR FILM BOIL, ONSET/COMP (DEG C) 54.39/ 153.34 15 TOTAL FOULING RESISTANCE 0.000000
**** SHELL CONSTRUCTION INFORMATION ****
21 SHELL TYPE E REAR HEAD PTFH SHELL ID (MM) 1000.000
22 SHELLS PARALLEL 1 TOTAL AREA (M2/SHELL) 138
23 PASSES SHELL 1 TUBE 1 - - - - - - - NO PROGRAM MESSAGES - - - - - -
24 SHELL ORIENTATION ANGLE 0 (DEGREES FROM VERTICAL)
25 PAIRS OF SEALING DEVICES 5
**** BAFFLE INFORMATION ****
26 BAFFLE TYPE SEGMENTAL BAFFLE CUT (PCT DIA) 20.90
27 CROSSPASSES 15 NO. (PCT AREA) (MM TO C.L.)
28 CENTRAL SPACING (MM) 235.000 1 18.595 291.000 **** BOILING SIDE PIPING DATA **** INLET OUTLET
29 INLET SPACING (MM) 235.000 16 DESIGN INSIDE DIAMETER (MM) 288.90 482.60
30 OUTLET SPACING (MM) 235.000 17 TOTAL LENGTH (MM)30000.00 5000.00
31 BAFFLE THICKNESS (MM) 6.808 18 VERTICAL HEIGHT (MM) 0.00
19 STATIC PRESSURE DROP (KPA) 3.99
**** TUBE INFORMATION **** 20 FRICTIONAL PRESSURE DROP (KPA) 0.88
32 TUBE TYPE PLAIN TUBECOUNT PER SHELL 500 21 TOTAL PIPE PRESSURE DROP (KPA) 3.12 4.87
33 OVERALL LENGTH (M) 3.658 22 VALVE PRESSURE DROP (KPA) 0.00 0.00
34 OUTSIDE DIAMETER (MM) 25.4000
35 TOTAL TUBSHEET THICK (MM)196.0 INSIDE DIAMETER (MM) 19.3100 **** DIAMETRAL CLEARANCES (MM) ****
36 AREA RATIO (OUT/IN) 1.315 PITCH (MM)31.7500 RATIO 1.250 BAFFLE-TO-SHELL BUNDLE-TO-SHELL TUBE-TO-BAFFLEHOLE
37 FIN EFFICIENCY 0.000 LAYOUT ANGLE (DEGREES) 45 23 5.6455 180.2912 0.6553
------------------------------------------------------------------------------------------------------------------------

HTRI AXIAL FLOW REBOILER PROGRAM RTF-2 MOD 7.21-1.30 HTRI VERSION PAGE NO- 12
RATING--TUBESIDE BOILING VERTICAL THERMOSIPHON REBOILER COCURRENT SENSIBLE LIQUID
PROBLEM DESCRIPTION-2-E-5900 : CONDENSATE DEBUTANIZE CASE-LoAGX1.1 FLOW=0 DT-ADJ=0 DP-ADJ=0
---Warning/Instability Messages--------------------------------------SI UNITS------------------------------------------
--------------------- STABILITY ANALYSIS MESSAGES ----------------------

STABLE SYSTEM

REDUCED INLET VELOCITY- THRESHOLD = 0.0077 ACTUAL = 0.2605


RATIO ACTUAL EXIT VELOCITY TO MAXIMUM STABLE EXIT VELOCITY =0.1719
------------------------------------------------------------------------

6/14
W:₩HEC₩050817_EGP3₩Design₩OtherOperSimulation₩2E-5900.lis

HTRI AXIAL FLOW REBOILER PROGRAM RTF-2 MOD 7.21-1.30 HTRI VERSION PAGE NO- 13
RATING--TUBESIDE BOILING VERTICAL THERMOSIPHON REBOILER COCURRENT SENSIBLE LIQUID
PROBLEM DESCRIPTION-2-E-5900 : CONDENSATE DEBUTANIZE CASE-LoAGX1.1 FLOW=0 DT-ADJ=0 DP-ADJ=0
---Supplementary Results---------------------------------------------SI UNITS------------------------------------------
LIQUID ZONE TWO-PHASE ZONE COLUMN
----------- -------------------------------------------------- REBOILER ENTRANCE/
INCREMENT 1 2 3 4 5 6 EXIT DISCHARGE
CONDITION
01 LENGTH (M) 0.208 0.651
02 WT FR VAPORIZED (--) 0.032 0.050 0.063 0.072 0.078 0.078 0.080
03 BOILING SIDE COEF (W/M2 C) 1444.96 1636.35 1472.71 1480.26 1465.19 1468.51
04 CONVECTIVE (W/M2 C) 1016.15 835.55 1274.73 1489.40 1559.83 1608.29
05 NUCLEATE BOILING (W/M2 C) 428.81 884.11 455.99 254.43 167.20 119.94
06 VAPOR PHASE (W/M2 C) 33779.93 9878.99 9793.58 9664.14 9771.98
07 HEATING SIDE COEF (W/M2 C) 787.30 787.31 787.31 787.31 787.31 787.31
08 OVERALL U(OUTER A) (W/M2 C) 443.70 465.70 447.10 448.02 446.19 446.59
09 BOIL SIDE BULK TEMP (DEG C) 195.73 196.34 197.99 198.99 199.64 200.07 200.21 200.05
10 HEAT SIDE BULK TEMP (DEG C) 268.71 257.44 238.92 226.75 218.49 212.89
11 BOIL SIDE WALL TEMP (DEG C) 225.21 219.36 214.45 209.97 207.14 205.15
12 BOIL SIDE DELTA T (DEG C) 29.48 23.01 16.45 10.98 7.50 5.08
13 BOIL SIDE PRESSURE (KPA) 1148.84 1145.66 1143.06 1140.73 1138.53 1136.10 1136.10 1131.00
14 BOILING FLOW REGIME BUBBLE BUBBLE SLUG SLUG SLUG
**** PHYSICAL PROPERTIES **** BOILING FLUID HEATING MEDIUM
(AT EXIT CONDITION) (EXIT FOR CONDENSING, AVG FOR SENSIBLE)
---------------------------- ----------------------------------------
LIQUID VAPOR LIQUID VAPOR
25 DENSITY (KG/M3) 575.047 30.860 797.534 0.000
26 VISCOSITY (MPA S) 0.12751 0.01130 0.24145 0.00000
27 THERMAL CONDUCTIVITY (W/M C) 0.0591 0.0311 0.0902 0.0000
28 HEAT CAPACITY (KJ/KG C) 2.856 2.500 2.332 0.000
29 ENTHALPY (IF SPECIFIED) (KJ/KG) 0.000 0.000 0.000 0.000
30 AVG MOLECULAR WEIGHT (KG/MOL) 89.53 100.00
31 CRITICAL TEMPERATURE * (DEG C) 287.01 0.00
32 CRITICAL PRESSURE * (KPA) 2997.00 0.00
33 LATENT HEAT * (KJ/KG) 219.11 0.00
34 SURFACE TENSION * (MN/M) 6.10 0.00
35 TEMPERATURE RANGE * (DEG C) 194.19 TO 213.39 199.99 TO 279.99
* WITHOUT INERT GAS, IF INERT GAS IS ADDED TO THE BOILING FLUID
------------------------------------------------------------------------------------------------------------------------

7/14
W:₩HEC₩050817_EGP3₩Design₩OtherOperSimulation₩2E-5900.lis

HTRI AXIAL FLOW REBOILER PROGRAM RTF-2 MOD 7.21-1.30 HTRI VERSION PAGE NO- 18
RATING--TUBESIDE BOILING VERTICAL THERMOSIPHON REBOILER COCURRENT SENSIBLE LIQUID
PROBLEM DESCRIPTION-2-E-5900 : CONDENSATE DEBUTANIZE CASE-Hi RR JT FLOW=0 DT-ADJ=0 DP-ADJ=0
---Final Results-----------------------------------------------------SI UNITS------------------------------------------
**** PROCESS DATA **** COLD TUBESIDE HOT SHELLSIDE **** SHELLSIDE PERFORMANCE ****
01 FLUID NAME BTMS HOT OIL 01 NOM VEL, X-FLOW/WINDOW 0.83/ 0.80
02 FLUID CONDITION BOIL. LIQUID SENS. LIQUID 02 FILM COEF, X-FLOW/WINDOW 2404.9/ 1392.0
03 TOTAL REBOILER FLOW (KG/S) 70.154 63.246* 03 FLOW FRACTIONS FOR HEAT TRANSFER= 0.549
04 BRANCH STREAM RATE (KG/S) 0.000 04 A=0.227 B=0.391 C=0.204 E=0.178
FEED / EXIT /DISCHRG INLET / OUTLET
05 WEIGHT FRACT VAPOR (--) 0.000 / 0.146 / 0.148 0.000 / 0.000 **** SHELLSIDE HEAT TRANSFER CORRECTIONS ****
06 TEMPERATURE (DEG C) 189.0 / 200.0 / 199.9 255.0 / 225.0 STDEL BETA GAMMA END FIN
07 PRESSURE (KPA) 1131.00 /1135.60 /1131.00 1090.00 /1064.50 05 1.000 0.905 1.000 1.000 0.000
**** PRESSURE DROPS **** (PERCENT OF TOTAL)
08 PRESSURE DROP, TOTAL/ALLOW (KPA) 22.38 / 22.48 25.50 / 50.00 CROSS WINDOW ENDS
09 LIQUID STATIC HEAD (M) 4.03 06 68.68 18.25 13.08
10 DESIGN VELOCITY (M/S) 0.84 0.65 NUCLEATE BOILING ****** FLOW REGIME ******
11 FILM COEF (OUTER A) (W/M2 C) 1316.54 1952.74 METHOD BEGIN MIDDLE END
12 FOULING RESISTANCE (M2 C/W) 0.000000 0.000000 07 REDUCED PROP BUBBLE SLUG SLUG
**** H.T. PARAMETERS **** SHELL TUBE
**** REBOILER PERFORMANCE CRITERIA **** 08 WALL CORRECTION 0.977
13 AVERAGE OVERALL HEAT TRANSFER COEF (W/M2 C) 746.49 09 MIDPOINT REYNOLDS NO 72920
14 HEAT DUTY, REQUIRED OR SPECIFIED (KW) 4406.00 10
15 TRUE MEAN TEMPERATURE DIFFERENCE (DEG C) 42.73 11
16 SPECIFIED BOILING RANGE (DEG C) 75.07 12
**** THERMAL RESISTANCES **** (PCT OVERALL)
17 HEAT FLUX, DESIGN/MAXIMUM (W/M2) 31962.60/ 62427.57 SHELL TUBE FOULING METAL
18 VAPOR RATE, GENERATED/TOTAL (KG/S) 10.38/ 10.38 13 38.08 56.48 0.00 5.449
19 MAX WETWALL SUPERHEAT (CONDENSING) (DEG C) 0.00 14 DIFFERENTIAL RESISTANCE 0.000001
20 TEMP DIFF FOR FILM BOIL, ONSET/COMP (DEG C) 44.22/ 128.35 15 TOTAL FOULING RESISTANCE 0.000000
**** SHELL CONSTRUCTION INFORMATION ****
21 SHELL TYPE E REAR HEAD PTFH SHELL ID (MM) 1000.000
22 SHELLS PARALLEL 1 TOTAL AREA (M2/SHELL) 138
23 PASSES SHELL 1 TUBE 1 - - - - - - - NO PROGRAM MESSAGES - - - - - -
24 SHELL ORIENTATION ANGLE 0 (DEGREES FROM VERTICAL)
25 PAIRS OF SEALING DEVICES 5
**** BAFFLE INFORMATION ****
26 BAFFLE TYPE SEGMENTAL BAFFLE CUT (PCT DIA) 20.90
27 CROSSPASSES 15 NO. (PCT AREA) (MM TO C.L.)
28 CENTRAL SPACING (MM) 235.000 1 18.595 291.000 **** BOILING SIDE PIPING DATA **** INLET OUTLET
29 INLET SPACING (MM) 235.000 16 DESIGN INSIDE DIAMETER (MM) 288.90 482.60
30 OUTLET SPACING (MM) 235.000 17 TOTAL LENGTH (MM)30000.00 5000.00
31 BAFFLE THICKNESS (MM) 6.808 18 VERTICAL HEIGHT (MM) 0.00
19 STATIC PRESSURE DROP (KPA) 2.94
**** TUBE INFORMATION **** 20 FRICTIONAL PRESSURE DROP (KPA) 1.55
32 TUBE TYPE PLAIN TUBECOUNT PER SHELL 500 21 TOTAL PIPE PRESSURE DROP (KPA) 3.73 4.50
33 OVERALL LENGTH (M) 3.658 22 VALVE PRESSURE DROP (KPA) 0.00 0.00
34 OUTSIDE DIAMETER (MM) 25.4000
35 TOTAL TUBSHEET THICK (MM)196.0 INSIDE DIAMETER (MM) 19.3100 **** DIAMETRAL CLEARANCES (MM) ****
36 AREA RATIO (OUT/IN) 1.315 PITCH (MM)31.7500 RATIO 1.250 BAFFLE-TO-SHELL BUNDLE-TO-SHELL TUBE-TO-BAFFLEHOLE
37 FIN EFFICIENCY 0.000 LAYOUT ANGLE (DEGREES) 45 23 5.6455 180.2912 0.6553
------------------------------------------------------------------------------------------------------------------------

HTRI AXIAL FLOW REBOILER PROGRAM RTF-2 MOD 7.21-1.30 HTRI VERSION PAGE NO- 19
RATING--TUBESIDE BOILING VERTICAL THERMOSIPHON REBOILER COCURRENT SENSIBLE LIQUID
PROBLEM DESCRIPTION-2-E-5900 : CONDENSATE DEBUTANIZE CASE-Hi RR JT FLOW=0 DT-ADJ=0 DP-ADJ=0
---Warning/Instability Messages--------------------------------------SI UNITS------------------------------------------
--------------------- STABILITY ANALYSIS MESSAGES ----------------------

STABLE SYSTEM--NO STABILITY THRESHOLD ENCOUNTERED


------------------------------------------------------------------------

8/14
W:₩HEC₩050817_EGP3₩Design₩OtherOperSimulation₩2E-5900.lis

HTRI AXIAL FLOW REBOILER PROGRAM RTF-2 MOD 7.21-1.30 HTRI VERSION PAGE NO- 20
RATING--TUBESIDE BOILING VERTICAL THERMOSIPHON REBOILER COCURRENT SENSIBLE LIQUID
PROBLEM DESCRIPTION-2-E-5900 : CONDENSATE DEBUTANIZE CASE-Hi RR JT FLOW=0 DT-ADJ=0 DP-ADJ=0
---Supplementary Results---------------------------------------------SI UNITS------------------------------------------
LIQUID ZONE TWO-PHASE ZONE COLUMN
----------- -------------------------------------------------- REBOILER ENTRANCE/
INCREMENT 1 2 3 4 5 6 EXIT DISCHARGE
CONDITION
01 LENGTH (M) 0.138 0.665
02 WT FR VAPORIZED (--) 0.045 0.077 0.104 0.127 0.146 0.146 0.148
03 BOILING SIDE COEF (W/M2 C) 1743.64 2024.70 1664.02 1613.05 1640.31 1714.19
04 CONVECTIVE (W/M2 C) 1064.94 739.76 1153.34 1460.46 1733.18 1984.36
05 NUCLEATE BOILING (W/M2 C) 678.70 1470.87 851.69 490.54 285.85 170.61
06 VAPOR PHASE (W/M2 C) 24072.56 9783.75 9312.09 8744.83 8380.58
07 HEATING SIDE COEF (W/M2 C) 1952.73 1952.74 1952.74 1952.74 1952.74 1952.74
08 OVERALL U(OUTER A) (W/M2 C) 746.39 809.68 726.81 713.85 720.82 739.24
09 BOIL SIDE BULK TEMP (DEG C) 190.33 191.61 194.27 196.26 197.94 199.35 200.01 199.87
10 HEAT SIDE BULK TEMP (DEG C) 254.07 249.81 242.40 236.64 231.83 227.73
11 BOIL SIDE WALL TEMP (DEG C) 226.22 222.35 221.91 219.64 217.35 215.36
12 BOIL SIDE DELTA T (DEG C) 35.89 30.74 27.64 23.37 19.41 16.01
13 BOIL SIDE PRESSURE (KPA) 1148.38 1145.26 1142.69 1140.36 1138.12 1135.60 1135.60 1131.00
14 BOILING FLOW REGIME BUBBLE SLUG SLUG SLUG SLUG
**** PHYSICAL PROPERTIES **** BOILING FLUID HEATING MEDIUM
(AT EXIT CONDITION) (EXIT FOR CONDENSING, AVG FOR SENSIBLE)
---------------------------- ----------------------------------------
LIQUID VAPOR LIQUID VAPOR
25 DENSITY (KG/M3) 570.520 31.000 799.046 0.000
26 VISCOSITY (MPA S) 0.12468 0.01100 0.24409 0.00000
27 THERMAL CONDUCTIVITY (W/M C) 0.0563 0.0305 0.0905 0.0000
28 HEAT CAPACITY (KJ/KG C) 2.867 2.487 2.326 0.000
29 ENTHALPY (IF SPECIFIED) (KJ/KG) 0.000 0.000 0.000 0.000
30 AVG MOLECULAR WEIGHT (KG/MOL) 87.97 100.00
31 CRITICAL TEMPERATURE * (DEG C) 287.01 0.00
32 CRITICAL PRESSURE * (KPA) 2997.00 0.00
33 LATENT HEAT * (KJ/KG) 224.07 0.00
34 SURFACE TENSION * (MN/M) 6.07 0.00
35 TEMPERATURE RANGE * (DEG C) 188.99 TO 205.69 199.99 TO 279.99
* WITHOUT INERT GAS, IF INERT GAS IS ADDED TO THE BOILING FLUID
------------------------------------------------------------------------------------------------------------------------

9/14
W:₩HEC₩050817_EGP3₩Design₩OtherOperSimulation₩2E-5900.lis

HTRI AXIAL FLOW REBOILER PROGRAM RTF-2 MOD 7.21-1.30 HTRI VERSION PAGE NO- 25
RATING--TUBESIDE BOILING VERTICAL THERMOSIPHON REBOILER COCURRENT SENSIBLE LIQUID
PROBLEM DESCRIPTION-2-E-5900 : CONDENSATE DEBUTANIZE CASE-WetGasBy FLOW=0 DT-ADJ=0 DP-ADJ=0
---Final Results-----------------------------------------------------SI UNITS------------------------------------------
**** PROCESS DATA **** COLD TUBESIDE HOT SHELLSIDE **** SHELLSIDE PERFORMANCE ****
01 FLUID NAME BTMS HOT OIL 01 NOM VEL, X-FLOW/WINDOW 0.51/ 0.49
02 FLUID CONDITION BOIL. LIQUID SENS. LIQUID 02 FILM COEF, X-FLOW/WINDOW 1746.9/ 1008.8
03 TOTAL REBOILER FLOW (KG/S) 70.163 38.470* 03 FLOW FRACTIONS FOR HEAT TRANSFER= 0.528
04 BRANCH STREAM RATE (KG/S) 0.000 04 A=0.233 B=0.384 C=0.204 E=0.179
FEED / EXIT /DISCHRG INLET / OUTLET
05 WEIGHT FRACT VAPOR (--) 0.000 / 0.121 / 0.123 0.000 / 0.000 **** SHELLSIDE HEAT TRANSFER CORRECTIONS ****
06 TEMPERATURE (DEG C) 191.0 / 200.1 / 200.0 261.8 / 221.2 STDEL BETA GAMMA END FIN
07 PRESSURE (KPA) 1131.00 /1135.56 /1131.00 1090.00 /1080.79 05 1.000 0.905 1.000 1.000 0.000
**** PRESSURE DROPS **** (PERCENT OF TOTAL)
08 PRESSURE DROP, TOTAL/ALLOW (KPA) 22.53 / 22.59 9.21 / 50.00 CROSS WINDOW ENDS
09 LIQUID STATIC HEAD (M) 4.03 06 69.06 17.53 13.41
10 DESIGN VELOCITY (M/S) 0.84 0.38 NUCLEATE BOILING ****** FLOW REGIME ******
11 FILM COEF (OUTER A) (W/M2 C) 1253.99 1418.16 METHOD BEGIN MIDDLE END
12 FOULING RESISTANCE (M2 C/W) 0.000000 0.000000 07 REDUCED PROP BUBBLE SLUG SLUG
**** H.T. PARAMETERS **** SHELL TUBE
**** REBOILER PERFORMANCE CRITERIA **** 08 WALL CORRECTION 0.975
13 AVERAGE OVERALL HEAT TRANSFER COEF (W/M2 C) 618.28 09 MIDPOINT REYNOLDS NO 43550
14 HEAT DUTY, REQUIRED OR SPECIFIED (KW) 3541.00 10
15 TRUE MEAN TEMPERATURE DIFFERENCE (DEG C) 41.46 11
16 SPECIFIED BOILING RANGE (DEG C) 83.04 12
**** THERMAL RESISTANCES **** (PCT OVERALL)
17 HEAT FLUX, DESIGN/MAXIMUM (W/M2) 26378.50/ 62428.78 SHELL TUBE FOULING METAL
18 VAPOR RATE, GENERATED/TOTAL (KG/S) 8.62/ 8.62 13 44.75 50.60 0.00 4.651
19 MAX WETWALL SUPERHEAT (CONDENSING) (DEG C) 0.00 14 DIFFERENTIAL RESISTANCE 0.000001
20 TEMP DIFF FOR FILM BOIL, ONSET/COMP (DEG C) 48.09/ 137.86 15 TOTAL FOULING RESISTANCE 0.000000
**** SHELL CONSTRUCTION INFORMATION ****
21 SHELL TYPE E REAR HEAD PTFH SHELL ID (MM) 1000.000
22 SHELLS PARALLEL 1 TOTAL AREA (M2/SHELL) 138
23 PASSES SHELL 1 TUBE 1 - - - - - - - NO PROGRAM MESSAGES - - - - - -
24 SHELL ORIENTATION ANGLE 0 (DEGREES FROM VERTICAL)
25 PAIRS OF SEALING DEVICES 5
**** BAFFLE INFORMATION ****
26 BAFFLE TYPE SEGMENTAL BAFFLE CUT (PCT DIA) 20.90
27 CROSSPASSES 15 NO. (PCT AREA) (MM TO C.L.)
28 CENTRAL SPACING (MM) 235.000 1 18.595 291.000 **** BOILING SIDE PIPING DATA **** INLET OUTLET
29 INLET SPACING (MM) 235.000 16 DESIGN INSIDE DIAMETER (MM) 288.90 482.60
30 OUTLET SPACING (MM) 235.000 17 TOTAL LENGTH (MM)30000.00 5000.00
31 BAFFLE THICKNESS (MM) 6.808 18 VERTICAL HEIGHT (MM) 0.00
19 STATIC PRESSURE DROP (KPA) 3.14
**** TUBE INFORMATION **** 20 FRICTIONAL PRESSURE DROP (KPA) 1.35
32 TUBE TYPE PLAIN TUBECOUNT PER SHELL 500 21 TOTAL PIPE PRESSURE DROP (KPA) 3.71 4.50
33 OVERALL LENGTH (M) 3.658 22 VALVE PRESSURE DROP (KPA) 0.00 0.00
34 OUTSIDE DIAMETER (MM) 25.4000
35 TOTAL TUBSHEET THICK (MM)196.0 INSIDE DIAMETER (MM) 19.3100 **** DIAMETRAL CLEARANCES (MM) ****
36 AREA RATIO (OUT/IN) 1.315 PITCH (MM)31.7500 RATIO 1.250 BAFFLE-TO-SHELL BUNDLE-TO-SHELL TUBE-TO-BAFFLEHOLE
37 FIN EFFICIENCY 0.000 LAYOUT ANGLE (DEGREES) 45 23 5.6455 180.2912 0.6553
------------------------------------------------------------------------------------------------------------------------

HTRI AXIAL FLOW REBOILER PROGRAM RTF-2 MOD 7.21-1.30 HTRI VERSION PAGE NO- 26
RATING--TUBESIDE BOILING VERTICAL THERMOSIPHON REBOILER COCURRENT SENSIBLE LIQUID
PROBLEM DESCRIPTION-2-E-5900 : CONDENSATE DEBUTANIZE CASE-WetGasBy FLOW=0 DT-ADJ=0 DP-ADJ=0
---Warning/Instability Messages--------------------------------------SI UNITS------------------------------------------
--------------------- STABILITY ANALYSIS MESSAGES ----------------------

STABLE SYSTEM--NO STABILITY THRESHOLD ENCOUNTERED


------------------------------------------------------------------------

10/14
W:₩HEC₩050817_EGP3₩Design₩OtherOperSimulation₩2E-5900.lis

HTRI AXIAL FLOW REBOILER PROGRAM RTF-2 MOD 7.21-1.30 HTRI VERSION PAGE NO- 27
RATING--TUBESIDE BOILING VERTICAL THERMOSIPHON REBOILER COCURRENT SENSIBLE LIQUID
PROBLEM DESCRIPTION-2-E-5900 : CONDENSATE DEBUTANIZE CASE-WetGasBy FLOW=0 DT-ADJ=0 DP-ADJ=0
---Supplementary Results---------------------------------------------SI UNITS------------------------------------------
LIQUID ZONE TWO-PHASE ZONE COLUMN
----------- -------------------------------------------------- REBOILER ENTRANCE/
INCREMENT 1 2 3 4 5 6 EXIT DISCHARGE
CONDITION
01 LENGTH (M) 0.138 0.665
02 WT FR VAPORIZED (--) 0.039 0.066 0.088 0.106 0.121 0.121 0.123
03 BOILING SIDE COEF (W/M2 C) 1586.07 1832.16 1561.05 1558.40 1633.76 1675.19
04 CONVECTIVE (W/M2 C) 1075.60 768.20 1183.21 1502.42 1797.92 1953.70
05 NUCLEATE BOILING (W/M2 C) 510.47 1219.85 657.63 353.03 188.43 108.39
06 VAPOR PHASE (W/M2 C) 23365.70 10270.92 9734.34 9203.97 8928.28
07 HEATING SIDE COEF (W/M2 C) 1418.15 1418.16 1418.16 1418.16 1418.16 1418.16
08 OVERALL U(OUTER A) (W/M2 C) 621.98 668.28 616.88 616.34 631.49 639.53
09 BOIL SIDE BULK TEMP (DEG C) 192.19 193.38 195.62 197.27 198.61 199.65 200.11 199.97
10 HEAT SIDE BULK TEMP (DEG C) 260.43 254.24 243.55 235.47 228.97 223.71
11 BOIL SIDE WALL TEMP (DEG C) 227.39 222.68 220.37 217.01 213.90 211.67
12 BOIL SIDE DELTA T (DEG C) 35.20 29.30 24.75 19.74 15.30 12.02
13 BOIL SIDE PRESSURE (KPA) 1148.49 1145.29 1142.66 1140.30 1138.05 1135.56 1135.56 1131.00
14 BOILING FLOW REGIME BUBBLE SLUG SLUG SLUG SLUG
**** PHYSICAL PROPERTIES **** BOILING FLUID HEATING MEDIUM
(AT EXIT CONDITION) (EXIT FOR CONDENSING, AVG FOR SENSIBLE)
---------------------------- ----------------------------------------
LIQUID VAPOR LIQUID VAPOR
25 DENSITY (KG/M3) 572.063 31.310 797.901 0.000
26 VISCOSITY (MPA S) 0.12524 0.01130 0.24208 0.00000
27 THERMAL CONDUCTIVITY (W/M C) 0.0584 0.0314 0.0903 0.0000
28 HEAT CAPACITY (KJ/KG C) 2.861 2.518 2.330 0.000
29 ENTHALPY (IF SPECIFIED) (KJ/KG) 0.000 0.000 0.000 0.000
30 AVG MOLECULAR WEIGHT (KG/MOL) 91.65 100.00
31 CRITICAL TEMPERATURE * (DEG C) 287.01 0.00
32 CRITICAL PRESSURE * (KPA) 2997.00 0.00
33 LATENT HEAT * (KJ/KG) 221.47 0.00
34 SURFACE TENSION * (MN/M) 6.10 0.00
35 TEMPERATURE RANGE * (DEG C) 190.99 TO 218.99 199.99 TO 279.99
* WITHOUT INERT GAS, IF INERT GAS IS ADDED TO THE BOILING FLUID
------------------------------------------------------------------------------------------------------------------------

11/14
W:₩HEC₩050817_EGP3₩Design₩OtherOperSimulation₩2E-5900.lis

HTRI AXIAL FLOW REBOILER PROGRAM RTF-2 MOD 7.21-1.30 HTRI VERSION PAGE NO- 32
RATING--TUBESIDE BOILING VERTICAL THERMOSIPHON REBOILER COCURRENT SENSIBLE LIQUID
PROBLEM DESCRIPTION-2-E-5900 : CONDENSATE DEBUTANIZE CASE-ETGL Byp FLOW=0 DT-ADJ=0 DP-ADJ=0
---Final Results-----------------------------------------------------SI UNITS------------------------------------------
**** PROCESS DATA **** COLD TUBESIDE HOT SHELLSIDE **** SHELLSIDE PERFORMANCE ****
01 FLUID NAME BTMS HOT OIL 01 NOM VEL, X-FLOW/WINDOW 0.41/ 0.39
02 FLUID CONDITION BOIL. LIQUID SENS. LIQUID 02 FILM COEF, X-FLOW/WINDOW 1545.8/ 892.9
03 TOTAL REBOILER FLOW (KG/S) 66.756 31.467* 03 FLOW FRACTIONS FOR HEAT TRANSFER= 0.543
04 BRANCH STREAM RATE (KG/S) 0.000 04 A=0.232 B=0.382 C=0.205 E=0.181
FEED / EXIT /DISCHRG INLET / OUTLET
05 WEIGHT FRACT VAPOR (--) 0.000 / 0.096 / 0.098 0.000 / 0.000 **** SHELLSIDE HEAT TRANSFER CORRECTIONS ****
06 TEMPERATURE (DEG C) 179.0 / 186.3 / 186.1 239.4 / 200.0 STDEL BETA GAMMA END FIN
07 PRESSURE (KPA) 1131.00 /1135.69 /1131.00 1090.00 /1083.43 05 1.000 0.905 1.000 1.000 0.000
**** PRESSURE DROPS **** (PERCENT OF TOTAL)
08 PRESSURE DROP, TOTAL/ALLOW (KPA) 22.31 / 22.42 6.57 / 50.00 CROSS WINDOW ENDS
09 LIQUID STATIC HEAD (M) 4.03 06 69.38 17.17 13.46
10 DESIGN VELOCITY (M/S) 0.80 0.31 NUCLEATE BOILING ****** FLOW REGIME ******
11 FILM COEF (OUTER A) (W/M2 C) 1330.99 1254.92 METHOD BEGIN MIDDLE END
12 FOULING RESISTANCE (M2 C/W) 0.000000 0.000000 07 REDUCED PROP BUBBLE SLUG SLUG
**** H.T. PARAMETERS **** SHELL TUBE
**** REBOILER PERFORMANCE CRITERIA **** 08 WALL CORRECTION 0.976
13 AVERAGE OVERALL HEAT TRANSFER COEF (W/M2 C) 624.35 09 MIDPOINT REYNOLDS NO 32417
14 HEAT DUTY, REQUIRED OR SPECIFIED (KW) 2811.00 10
15 TRUE MEAN TEMPERATURE DIFFERENCE (DEG C) 32.59 11
16 SPECIFIED BOILING RANGE (DEG C) 70.84 12
**** THERMAL RESISTANCES **** (PCT OVERALL)
17 HEAT FLUX, DESIGN/MAXIMUM (W/M2) 20335.26/ 62424.69 SHELL TUBE FOULING METAL
18 VAPOR RATE, GENERATED/TOTAL (KG/S) 6.54/ 6.54 13 49.14 46.34 0.00 4.520
19 MAX WETWALL SUPERHEAT (CONDENSING) (DEG C) 0.00 14 DIFFERENTIAL RESISTANCE 0.000001
20 TEMP DIFF FOR FILM BOIL, ONSET/COMP (DEG C) 42.16/ 123.30 15 TOTAL FOULING RESISTANCE 0.000000
**** SHELL CONSTRUCTION INFORMATION ****
21 SHELL TYPE E REAR HEAD PTFH SHELL ID (MM) 1000.000
22 SHELLS PARALLEL 1 TOTAL AREA (M2/SHELL) 138
23 PASSES SHELL 1 TUBE 1 - - - - - - - NO PROGRAM MESSAGES - - - - - -
24 SHELL ORIENTATION ANGLE 0 (DEGREES FROM VERTICAL)
25 PAIRS OF SEALING DEVICES 5
**** BAFFLE INFORMATION ****
26 BAFFLE TYPE SEGMENTAL BAFFLE CUT (PCT DIA) 20.90
27 CROSSPASSES 15 NO. (PCT AREA) (MM TO C.L.)
28 CENTRAL SPACING (MM) 235.000 1 18.595 291.000 **** BOILING SIDE PIPING DATA **** INLET OUTLET
29 INLET SPACING (MM) 235.000 16 DESIGN INSIDE DIAMETER (MM) 288.90 482.60
30 OUTLET SPACING (MM) 235.000 17 TOTAL LENGTH (MM)30000.00 5000.00
31 BAFFLE THICKNESS (MM) 6.808 18 VERTICAL HEIGHT (MM) 0.00
19 STATIC PRESSURE DROP (KPA) 3.51
**** TUBE INFORMATION **** 20 FRICTIONAL PRESSURE DROP (KPA) 1.07
32 TUBE TYPE PLAIN TUBECOUNT PER SHELL 500 21 TOTAL PIPE PRESSURE DROP (KPA) 3.39 4.58
33 OVERALL LENGTH (M) 3.658 22 VALVE PRESSURE DROP (KPA) 0.00 0.00
34 OUTSIDE DIAMETER (MM) 25.4000
35 TOTAL TUBSHEET THICK (MM)196.0 INSIDE DIAMETER (MM) 19.3100 **** DIAMETRAL CLEARANCES (MM) ****
36 AREA RATIO (OUT/IN) 1.315 PITCH (MM)31.7500 RATIO 1.250 BAFFLE-TO-SHELL BUNDLE-TO-SHELL TUBE-TO-BAFFLEHOLE
37 FIN EFFICIENCY 0.000 LAYOUT ANGLE (DEGREES) 45 23 5.6455 180.2912 0.6553
------------------------------------------------------------------------------------------------------------------------

HTRI AXIAL FLOW REBOILER PROGRAM RTF-2 MOD 7.21-1.30 HTRI VERSION PAGE NO- 33
RATING--TUBESIDE BOILING VERTICAL THERMOSIPHON REBOILER COCURRENT SENSIBLE LIQUID
PROBLEM DESCRIPTION-2-E-5900 : CONDENSATE DEBUTANIZE CASE-ETGL Byp FLOW=0 DT-ADJ=0 DP-ADJ=0
---Warning/Instability Messages--------------------------------------SI UNITS------------------------------------------
--------------------- STABILITY ANALYSIS MESSAGES ----------------------

STABLE SYSTEM--NO STABILITY THRESHOLD ENCOUNTERED


------------------------------------------------------------------------

12/14
W:₩HEC₩050817_EGP3₩Design₩OtherOperSimulation₩2E-5900.lis

HTRI AXIAL FLOW REBOILER PROGRAM RTF-2 MOD 7.21-1.30 HTRI VERSION PAGE NO- 34
RATING--TUBESIDE BOILING VERTICAL THERMOSIPHON REBOILER COCURRENT SENSIBLE LIQUID
PROBLEM DESCRIPTION-2-E-5900 : CONDENSATE DEBUTANIZE CASE-ETGL Byp FLOW=0 DT-ADJ=0 DP-ADJ=0
---Supplementary Results---------------------------------------------SI UNITS------------------------------------------
LIQUID ZONE TWO-PHASE ZONE COLUMN
----------- -------------------------------------------------- REBOILER ENTRANCE/
INCREMENT 1 2 3 4 5 6 EXIT DISCHARGE
CONDITION
01 LENGTH (M) 0.208 0.651
02 WT FR VAPORIZED (--) 0.035 0.056 0.073 0.086 0.096 0.096 0.098
03 BOILING SIDE COEF (W/M2 C) 1750.91 2079.06 1759.64 1683.22 1626.83 1605.01
04 CONVECTIVE (W/M2 C) 1107.64 1014.65 1460.20 1648.63 1738.30 1804.66
05 NUCLEATE BOILING (W/M2 C) 643.26 1191.05 664.81 371.65 221.49 133.17
06 VAPOR PHASE (W/M2 C) 36211.41 10234.14 10088.88 9575.53 9345.04
07 HEATING SIDE COEF (W/M2 C) 1254.92 1254.92 1254.92 1254.92 1254.92 1254.92
08 OVERALL U(OUTER A) (W/M2 C) 616.74 665.41 618.17 605.47 595.70 591.82
09 BOIL SIDE BULK TEMP (DEG C) 180.57 181.21 183.10 184.36 185.29 186.01 186.29 186.13
10 HEAT SIDE BULK TEMP (DEG C) 236.54 230.57 220.40 213.04 207.48 203.22
11 BOIL SIDE WALL TEMP (DEG C) 206.50 202.13 200.41 197.87 195.92 194.28
12 BOIL SIDE DELTA T (DEG C) 25.94 20.92 17.31 13.51 10.63 8.27
13 BOIL SIDE PRESSURE (KPA) 1148.26 1145.13 1142.56 1140.26 1138.09 1135.69 1135.69 1131.00
14 BOILING FLOW REGIME BUBBLE SLUG SLUG SLUG SLUG
**** PHYSICAL PROPERTIES **** BOILING FLUID HEATING MEDIUM
(AT EXIT CONDITION) (EXIT FOR CONDENSING, AVG FOR SENSIBLE)
---------------------------- ----------------------------------------
LIQUID VAPOR LIQUID VAPOR
25 DENSITY (KG/M3) 569.128 30.640 814.406 0.000
26 VISCOSITY (MPA S) 0.12708 0.01100 0.27394 0.00000
27 THERMAL CONDUCTIVITY (W/M C) 0.0621 0.0305 0.0936 0.0000
28 HEAT CAPACITY (KJ/KG C) 2.844 2.475 2.266 0.000
29 ENTHALPY (IF SPECIFIED) (KJ/KG) 0.000 0.000 0.000 0.000
30 AVG MOLECULAR WEIGHT (KG/MOL) 86.14 100.00
31 CRITICAL TEMPERATURE * (DEG C) 287.01 0.00
32 CRITICAL PRESSURE * (KPA) 2997.00 0.00
33 LATENT HEAT * (KJ/KG) 227.99 0.00
34 SURFACE TENSION * (MN/M) 6.10 0.00
35 TEMPERATURE RANGE * (DEG C) 178.99 TO 200.49 199.99 TO 279.99
* WITHOUT INERT GAS, IF INERT GAS IS ADDED TO THE BOILING FLUID
------------------------------------------------------------------------------------------------------------------------

13/14
W:₩HEC₩050817_EGP3₩Design₩OtherOperSimulation₩2E-5900.lis

HTRI AXIAL FLOW REBOILER PROGRAM RTF-2 MOD 7.21-1.30 HTRI VERSION PAGE NO- 35
RATING--TUBESIDE BOILING VERTICAL THERMOSIPHON REBOILER COCURRENT SENSIBLE LIQUID
PROBLEM DESCRIPTION-2-E-5900 : CONDENSATE DEBUTANIZE CASE-ETGL Byp FLOW=0 DT-ADJ=0 DP-ADJ=0
---Summary Printout--------------------------------------------------SI UNITS------------------------------------------
CASE IDENTIFICATION HiAGX1.1 LoAGX1.1 Hi RR JT WetGasBy ETGL Byp
SHELL INFORMATION
SHELLS IN PARALLEL 1 1 1 1 1
SURFACE AREA/SHELL 138 138 138 138 138
SHELLSIDE FLUID HEATING HEATING HEATING HEATING HEATING
SHELL ORIENTATION 0 0 0 0 0
SHELL ID 1000.000 1000.000 1000.000 1000.000 1000.000
BAFFLE TYPE SEGMENTAL SEGMENTAL SEGMENTAL SEGMENTAL SEGMENTAL
CUT 20.90 20.90 20.90 20.90 20.90
CENTRAL SPACING 235.000 235.000 235.000 235.000 235.000
NUMBER CROSSPASSES 15 15 15 15 15
TUBE INFORMATION
TUBE TYPE PLAIN PLAIN PLAIN PLAIN PLAIN
NUMBER TUBES/SHELL 500 500 500 500 500
TUBE LENGTH OVERALL 3.658 3.658 3.658 3.658 3.658
TUBE OD 25.4000 25.4000 25.4000 25.4000 25.4000
TUBE LAYOUT ANGLE 45 45 45 45 45
PITCH RATIO 1.250 1.250 1.250 1.250 1.250
TEMPERATURE
BOILING IN/EXIT 190/ 204 194/ 200 189/ 200 191/ 200 179/ 186
DISCHARGE 204 200 200 200 186
HEATING IN/OUT 263/ 236 275/ 209 255/ 225 262/ 221 239/ 200
WEIGHT FRACTION VAPOR
BOILING IN 0.000 0.000 0.000 0.000 0.000
EXIT 0.185 0.078 0.146 0.121 0.096
DISCHARGE 0.187 0.080 0.148 0.123 0.098
HEATING IN 0.000 0.000 0.000 0.000 0.000
OUT 0.000 0.000 0.000 0.000 0.000
** PERFORMANCE ANALYSIS **
REQUIRED HEAT DUTY 5436.8 2137.3 4406.0 3541.0 2811.0
DIFFERENTIAL RESIST 0.000001 0.000001 0.000001 0.000001 0.000001
AVG HT COEFFICIENTS
OVERALL 788.65 442.52 746.49 618.28 624.35
BOILING SIDE 1310.53 1141.13 1316.54 1253.99 1330.99
HEATING SIDE 2368.82 787.31 1952.74 1418.16 1254.92
AVG OVERALL DELTA T 49.91 34.97 42.73 41.47 32.60
BOILING PRESS DROP 22.30 22.52 22.38 22.53 22.31
ALLOWABLE 22.47 22.74 22.48 22.59 22.42
HEATING PRESS DROP 46.30 1.45 25.50 9.21 6.57
ALLOWABLE 50.00 50.00 50.00 50.00 50.00
LIQUID STATIC HEAD 4.03 4.03 4.03 4.03 4.03
DESIGN HEAT FLUX 40018.2 15832.1 31962.6 26378.5 20335.3
MAXIMUM HEAT FLUX 62424.7 62412.6 62427.6 62428.8 62424.7
REBOILER FLOW RATE 69.70 64.40 70.15 70.16 66.76
PROGRAM MESSAGES NONE NONE NONE NONE NONE
INSTABILITY CHECK
------------------------------------------------------------------------------------------------------------------------

14/14
Document No. Rev Company Comments HHI’s Response Remark

0NS-HHI-GP-DAS-PR-0011 5 1. Update the heating curves for consistency with 1. Simulation result was not changed. Current heating
(2-E-5900) the revised datasheet conditions. curve is accordingly correct. Meanwhile, process data
in datasheet has been updated based on actual
hydraulics of thermo-syphon. (piping lay out and
equipment friction loss)
The words, “Vapor & friction” was revised to “Vapor
friction(mole)” in the heat release table.

2. Verify the 20" outlet nozzle is correct since it


2. Velocity and rho-v2 is 2.71 m/s and 984.5 kg/m-s2
has been decreased from the 14" prior size.
respectively in 20” outlet nozzle. Therefore 20” outlet
nozzle is correct.

3. This datasheet contains the wrong 3. It was attached correctly in the datasheet(Rev.6)
attachments. A correct set of attachments was
provided to CNL via hardcopy. Please reissue
this datasheet with the correct attachments.

4. There are multiple Korean characters on the 4. It seems to be a print setting error.(Acrobat 7.0)
datasheet. Please correct. Please print it with print option “image print” in Acrobat
program
5. The allowable hot oil pressure drop has been
decreased from 1.03 to 0.3 bar. Sufficient 5. Allowable pressure drop was revised/fitted based
pressure drop allowances must be maintained in on calculated pressure drop (0.1 bar)
the overall hot oil loop. Please submit, via RFI, a
summary sketch of the hot oil system showing
the calculated and allowed pressure drops
through the entire network, including exchangers,
piping, and valves.