Professional Documents
Culture Documents
TEMA Type E Heat Exchanger Design
TEMA Type E Heat Exchanger Design
http://excelcalculations.blogspot.com
This spreadsheet helps you design a TEMA Type E heat exchanger with the Bell-Delaware method
Enter parameters only in the pink cells
Rem<100
j=a*Rem^b
a b
Array
1 Triangle (30°) Pt/D= 1.25 1,81 -0,72
2 Square Pt/D=1.25 0,97 -0,62
3 Rotated Square Pt/D=1.25 1,81 -0,72
4 Triangle (30°) Pt/D= 1.5 1,34 -0,68
5 Square Pt/D=1.5 0,88 -0,64
2 Selected array 0,97 -0,62
a b
Array
1 Triangle (60°) Pt/D= 1.25 4,376 -1,025
2 Square Pt/D=1.25 3,923 -0,984
3 Rotated Square Pt/D=1.25 3,923 -0,984
4 Triangle (60°) Pt/D= 1.5 3,196 -1,176
5 Square Pt/D=1.5 3,04 -1,13
2 Selected Array 3,923 -0,984
a -7,907
b 1,774
c -0,16
d 0,00407
f 0,112189
ger Design
l-Delaware method
Geometric Data
Number of Shells in Series 2
Number of Tubes Per Shell 393
Number of Tubes in Window 95
Number of Tubes in Central Row 22
Number of Tubes Crossing the Baffle 339
Num Tubes Rows Between
Consecutive Baffles Edges 12
Separation Between Rows 0,022 m
Shell Diameter 0,609 m
Baffle Diameter 0,6043 m
Baffle Cut 0,15225 m
Baffle Central Angle in Degrees 120
Tubes External Diameter 0,018 m
Tubes Internal Diameter 0,016 m
Baffle Holes Diameter 0,02 m
Tubes Pitch 0,0254 m
Number of Tube Passes 1
Number of Baffles 16
Number of Sealing Strips Pairs 2
Tube Length 6 m
Baffles Spacing 0,234 m
Internal Fouling Ressistance 0,0007 m2 K W-1
2 -1
External Fouling Ressistance 0,0005 m KW
Wall Temperature
Shell Side Mean Temp 91 °C
Tube-Side Mean Temp 47,5 °C
Wall mean temp #NOME? °C
100<Rem<1300 1300<Rem<3000
c d a b c d a b
c d a b c d