ECM Check List Doc No: ECM-13 Check List No:3 Rev.1 Genting Sanyen Electrical Department

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 4

ECM Check List Doc No: ECM-13

Check List No:3 Rev.1


Genting Sanyen
NAME Electrical Department
DATE:
PM1 TRANSFORMER AND ROOM CHECKING LIST

TRANS TEMP. PRESS TRANS CABLE TX/CLEAN OIL O/LEAK


SET ACT SET ACT COND COND (TES/NO) LEVEL (YES/NO)
SP MCC1 90 0.24
MCC2 90 0.24
MCC3 90 0.24
MCC8 90 0.22
PM MCC5 90 0.24
MCC6 90 0.22
MCC7 90 0.22
SA1 90 0.22
SA2 90 0.22
B/SERV 90 0.24
REW IMPACT 90 0.26
S/DRIVE 90 5 kpa
CORE ROLL/G 90

MAIN VOLT AMP SPAJ SPA.LED D/COMP. DOC/DRG CB.TEMP POWER


S/B L1 L2 L3 N L1 L2 L3 N DISPLAY (ON/OFF) (YES/NO) (YES/NO) (N/ABN.) FACTOR
EB
LT
IMPAC
R/GR
CORE

ROOM R/CLEAN(Y/N) R/ TEMP. V/FAN.RUN (Y/N) LGT.(Y/N) D/CLOSE Check List Analysis:
TX/PM
TX/SP
IMPAC
CORE Comment:
ECM Check List Doc No: ECM-13
Check List No:3 Rev.2
Genting Sanyen
NAME Electrical Department
DATE:
PM1 TRANSFORMER AND ROOM CHECKING LIST

TRANS TEMP. PRESS TRANS CABLE TX/CLEAN OIL O/LEAK


SET ACT SET ACT COND COND (TES/NO) LEVEL (YES/NO)
SP MCC1 90 0.24
MCC2 90 0.24
MCC3 90 0.24
MCC8 90 0.22
PM MCC5 90 0.24
MCC6 90 0.22
MCC7 90 0.22
SA1 90 0.22
SA2 90 0.22
B/SERV 90 0.24
REW IMPACT 90 0.26
S/DRIVE 90 5 kpa
CORE ROLL/G 90 0.22

MAIN VOLT AMP SPAJ SPA.LED D/COMP. DOC/DRG CB.TEMP POWER


S/B L1 L2 L3 N L1 L2 L3 N DISPLAY (ON/OFF) (YES/NO) (YES/NO) (N/ABN.) FACTOR
EB
LT
IMPAC
R/GR
CORE

ROOM R/CLEAN(Y/N) R/ TEMP. V/FAN.RUN (Y/N) LGT.(Y/N) D/CLOSE Check List Analysis:
TX/PM
TX/SP
IMPAC
CORE Comment:
Doc No: ECM-13
Rev.3
Genting Sanyen
NAME Electrical Department
DATE:
PM1 TRANSFORMER AND ROOM CHECKING LIST

TRANS TEMP. PRESS TRANS CABLE TX/CLEAN OIL O/LEAK


SET ACT SET ACT COND COND (TES/NO) LEVEL (YES/NO)
SP MCC1 90 0.24
MCC2 90 0.24
MCC3 90 0.24
MCC8 90 0.22
PM MCC5 90 0.24
MCC6 90 0.22
MCC7 90 0.22
SA1 90 0.22
SA2 90 0.22
B/SERV 90 0.24
REW IMPACT 90 0.26
S/DRIVE 90 5 kpa
CORE ROLL/G 90 0.22

MAIN VOLT AMP SPAJ SPA.LED D/COMP. DOC/DRG CB.TEMP POWER


S/B L1 L2 L3 N L1 L2 L3 N DISPLAY (ON/OFF) (YES/NO) (YES/NO) (N/ABN.) FACTOR
EB
LT
IMPAC
R/GR
CORE

ROOM R/CLEAN(Y/N) R/ TEMP. V/FAN.RUN (Y/N) LGT.(Y/N) D/CLOSE Check List Analysis:
TX/PM
TX/SP
IMPAC
CORE Comment:
Doc No: ECM-13
Rev.4
GS Paper & Packaging Sdn Bhd
NAME Electrical Department
DATE:
PM1 TRANSFORMER AND ROOM CHECKING LIST

TRANS TEMP. PRESS TRANS CABLE TX/CLEAN OIL O/LEAK


SET ACT SET ACT COND COND (TES/NO) LEVEL (YES/NO)
SP MCC1 90 0.24
MCC2 90 0.24
MCC3 90 0.24
MCC8 90 0.22
PM MCC5 90 0.24
MCC6 90 0.22
MCC7 90 0.22
SA1 90 0.22
SA2 90 0.22
B/SERV 90 0.24
REW IMPACT 90 0.26
S/DRIVE 90 5 kpa
CORE ROLL/G 90 0.22

MAIN VOLT AMP SPAJ SPA.LED D/COMP. DOC/DRG CB.TEMP POWER


S/B L1 L2 L3 N L1 L2 L3 N DISPLAY (ON/OFF) (YES/NO) (YES/NO) (N/ABN.) FACTOR
EB
LT
IMPAC
R/GR
CORE

ROOM R/CLEAN(Y/N) R/ TEMP. V/FAN.RUN (Y/N) LGT.(Y/N) D/CLOSE Check List Analysis:
TX/PM
TX/SP
IMPAC
CORE Comment: