the Mk61/Mk62. The ANSI compliant meter is designed to supply a comprehensive portfolio of revenue-grade features. Mk61/Mk62 has the competency to offer multiple communications option. It has also the capability of storing meter data up to 12 months of its history.
KEY FEATURES
MULTIPLE UPGRADEABLE MEASURE LARGE ANTI
COMMS OPTIONS EVERYTHING LCD DISPLAY TAMPER Mk61/Mk62 Single Phase ANSI Meter SPECIFICATIONS
Measurement Billing Reset Environmental
• Compliance with ANSI C12.1, C12.10, C12.18, • Automatic monthly billing reset • Operating Range: - 40°C to + 70°C C12.19 and C12.20 • Storage of 12 billing reset data plus current • Limit Range: -45°C to + 75°C • Class of Accuracy 0.5 • Storage Range: - 45°C to + 80°C Time Clock & Calendar • FM1S: 1 phase 2 wire (Mk61) • Relative Humidity: up to 75% mean, 95% non- o • FM2S: 1 phase 3 wire (Mk62) • Accuracy within 0.5 seconds per day at 23 C condensing for 30 days • Backup time of 10 Years without Power • Ingress Protection: IP54 Voltage & Power Suuply (Lithium Battery) • Rated Voltage: 120V or 240V Physical Dimensions • Operating Range: 0.75Un - 1.9Un Large LCD Display • Standard Version: Approx 176mm • Burden: <1W, 5VA • Large 7-Segment Display (D)×131mm (H) • Frequency: 50Hz or 60Hz • Display Size: 15mm (H) • Weight: Approx.0.9kg for CT, Approx. 0.85kg for Shunt Current • Configurable to 14-user defined screens of any parameters (optional) Compliance • CT Range: 15/100A, 30/200A • Display Available even without Mains Power • Energy Regulatory Commission Certified • CT Limit: 30 times Imax for 0.5 seconds • Shunt : 15(100)A • Battery Option • Burden: < 0.25VA for CT, <1W for Shunt • Internal Battery • Voltage: 3.6V nominal Measured Energy Values • Operating Range: 3.4 to 3.8V • Import/Export Wh, • Carryover: 12-year continues usage or 20- • Absolute Wh, year shelf life • Instantaneous kW, I, V Security • Power Factor, Frequency, Phasor Angles • 2 levels of password • Maximum demand (optional) • Level 1 for reading & writing; Level 2 for Time of Use reading only • Up to 4 rates plus a unifide rate for with 8 time Communications slots each day • Optical Port: ANSI type, 9600bps • Programmable rates for workday and weekend day • Isolated RS485 (optional)
• Up to 10 seasons each year • RF - 433Mhz/915Mhz (optional)
• Up to 2 schedules each season • PLC communication (optional)
Event Logs Software
• Total 50 events with time date and time stamp • EDMI Software Available for Meter Programming & Reading (Windows Visa/ • Power on/off, Reset event data, Reset Energy XP/2000) data • Supported by AMR systems • Time of Demand
Download full ebook of Google Cloud Platform Gcp Professional Cloud Network Engineer Certification Companion Learn And Apply Network Design Concepts To Prepare For The Exam 1St Edition Dario Cabianca online pdf all chapter docx