235

Valves & volume control dampers

Multi-leaf dampers B01 236

Constant volume control dampers (CAV) B02 258

Iris dampers B03 268

Circular control valves B04 269

Variable Volume valves (VAV) B05 279

Healthconnectors B06 285


B

www.sigairhandling.be
B - Valves & volume control dampers

236
B01

Multi-leaf dampers
JS 250E P.237 JS 250 P.238 JS 251 P.241 JL 254 P.243 JL 255 P.246

¾ Multi-leaf dampers ¾ Multi-leaf dampers ¾ Multi-leaf dampers ¾ Multi-leaf dampers ¾ Multi-leaf dampers
¾ Standard, 100 mm blades ¾ Standard, 100 mm blades ¾ Standard, 165 mm blades ¾ Air tight, 100 mm blades ¾ Air tight, 165 mm blades
¾ Galvanized steel ¾ Galvanized steel ¾ Galvanized steel ¾ Galvanized steel ¾ Galvanized steel
¾ EN 1751-4 ¾ EN 1751-4

JS 251BS+ P.253 JL 255BS+ P.254 ESAS P.255


ML ML+SD

¾ Multi-leaf dampers ¾ Multi-leaf dampers ¾ Smoke valves


¾ Standard, 165 mm blades ¾ Air tight, 165 mm blades ¾ Rectangular
¾ Galvanized steel ¾
¾
Galvanized steel
EN 1751-4
¾
¾
Galvanized steel
EN12101-8
B

www.sigairhandling.be
B - Valves & volume control dampers

237
B01
Multi-leaf dampers
JS 250E
Multi-leaf dampers in galvanized steel assembled together from detached stock pieces.
Application
¾ For air-stream regulation in ventilation and airconditioning systems

Material
¾ Galvanized steel blades, frame, bolts and round axle
¾ Aluminium gears
¾ Polyamid bearings

Composition
¾ Galvanized steel aerodynamic designed regulation blades of 100 mm width containing aluminium
gears for simultanious counter-rotating operation of the damper
¾ Galvanized steel axle of Ø12mm and length 100 mm mounted on one of the above blades. A
borehole at the end of the axle is made to easily mount an axle extention LOA
¾ Galvanized steel housing with depth of 120mm and flange of 30 mm, made out of 2 vertical panels
with polyamid bearings and 2 horizontal panels, all bolted together
¾ Only standard dimensions available, with short delivery times

Mounting 120 10
¾ To be mounted between rectangular ducts with flanges of 30mm

30

30
¾ To be surface mounted on wall, floor or ceiling

Accessories
¾ Manual control handle with fixing system type MCS-250K
¾ Horizontal sealing between the valves type RVK8371

H
¾ Horizontal sealing between the frame and the topvalve type RVK8372
¾ Axle extentions LOA 100, LOA 150, LOA 200
¾ Actuators BELIMO

Prices
Article number - = B010102 x y L
L [mm]
200 300 400 500 600 700 800 900 1000
x=
200 300 400 500 600 700 800 900 A00
H [mm] y= Price (*)
207 207 78.20 79.54 81.88 84.22 81.58 94.46 96.84 106.00 107.00
307 307 88.54 90.20 92.88 95.88 107.00 108.00 111.00 122.00 125.00
407 407 98.22 100.00 103.00 107.00 133.00 135.00 138.00 151.00 154.00 B
507 507 113.00 115.00 131.00 135.00 150.00 153.00 157.00 172.00 176.00
607 607 135.00 138.00 141.00 146.00 163.00 166.00 171.00 188.00 192.00
707 707 145.00 148.00 152.00 158.00 190.00 193.00 198.00 217.00 222.00
807 807 155.00 158.00 161.00 182.00 203.00 206.00 212.00 233.00 239.00
907 907 169.00 172.00 190.00 197.00 220.00 223.00 230.00 253.00 260.00
1007 A07 179.00 183.00 201.00 208.00 233.00 237.00 245.00 270.00 277.00
(*) Delivery in one week

Prices
JS 250E MCS (**) LOA (**)
Article number Article number Price Article number Price
All articles B010501001000 12.52 ˜ B010501003100 5.70 ˜
(**) MCS: See page 247; LOA: See page 248

B01 JS 250E 1/1 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

238
B01
Multi-leaf dampers
JS 250
Multi-leaf dampers in galvanized steel.
Application
¾ For airstream regulation in ventilation and airconditioning systems

Material
¾ Galvanized steel blades, frame, and round axle
¾ Aluminium gears
¾ Polyamid bearings

Composition
¾ Galvanized steel aerodynamic designed regulation blades of 100 mm width containing aluminium
gears for simultanious counter-rotating operation of the damper
¾ Galvanized steel axle of Ø 12 mm and length 100 mm mounted on one of the above blades, wich
extends 67 mm outside the damperflanges. Axle with borehole at its end to easily mount axle
extension LOA 100 M or LOA 150 M (upon request), when a longer axle is required.
¾ Galvanized steel housing with depth of 110 mm and flange of 30 mm, made out of 2 vertical panels
with polyamid bearings and 2 horizontal panels, all welded together
¾ All dampers are made to measure. To obtain the exact height of the damper when in-between
sizes are ordered, the upper and lower frame will be bended towards or away from the middle of
the damper (see drawing), to make a execellent fit with as much as possible standard fitted blades.
Due to this fact the free area of the damper can become less than the opening of the LXH dimension.
Mounting
¾ To be mounted between rectangular ducts with flanges of 30 mm
¾ To be surface mounted on wall, floor or ceiling

Accessories
¾ Manual control handle with fixing system type MCS-250/254
¾ Horizontal sealing between the valves available upon request (+10%)
¾ Mounted axle extensions type LOA 100 M, LOA 150 M
¾ Extra axle available upon request
¾ Square axle end of 9 x 9 mm type SQE
¾ Actuators BELIMO
¾ Alternative bearings:
¾ PTFE bearings for low and high temperature applications type TBS (from -50°C to 200°C)
¾ Brass bearings for high temperature applications type MBS (up to 250°C)
¾ Ball bearings for high temperature applications at high pressure type BBS (up to 80°C and
2500Pa)
¾ Horizontal mounted coupling system type HVM
¾ Alternative outer-mechanism (for high temperature applications) (dimension D=140 in stead of
110 mm) B
¾ Counter-rotating blades (+20%)
¾ Parallel moving blades (+20%)
¾ Reinforced frames (+5%)
¾ Multi-leaf damper with vertical blades (+15%)
¾ Alternative construction materials
¾ Aluminium (x3.5)
¾ Stainless steel (INOX304) (x5.6)
¾ Stainless steel (INOX316) (x6.75)
¾ Aluminium blades with galvanized steel frame (x1.75)
¾ Version ATEX available upon request

B01 JS 250 1/3 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

B01 239

Multi-leaf dampers
JS 250
Prices
Article number - = B010101 x y
L [mm]
200 250 300 350 400 450 500 550 600 650 700 750
x=
200 250 300 350 400 450 500 550 600 650 700 750
H [mm] y= Price
200 200 67.30 70.44 70.44 73.56 73.56 76.70 76.70 79.82 79.82 82.96 82.96 86.08
250 250 86.08 89.22 89.22 92.34 92.34 97.04 97.04 100.00 100.00 103.00 103.00 108.00
300 300 86.08 89.22 89.22 92.34 92.34 97.04 97.04 100.00 100.00 103.00 103.00 108.00
350 350 103.00 108.00 108.00 113.00 113.00 116.00 116.00 121.00 121.00 125.00 125.00 131.00
400 400 103.00 108.00 108.00 113.00 113.00 116.00 116.00 121.00 121.00 125.00 125.00 131.00
450 450 122.00 127.00 127.00 131.00 131.00 136.00 136.00 141.00 141.00 147.00 147.00 153.00
500 500 122.00 127.00 127.00 131.00 131.00 136.00 136.00 141.00 141.00 147.00 147.00 153.00
550 550 139.00 146.00 146.00 150.00 150.00 157.00 157.00 161.00 161.00 169.00 169.00 175.00
600 600 139.00 146.00 146.00 150.00 150.00 157.00 157.00 161.00 161.00 169.00 169.00 175.00
650 650 158.00 164.00 164.00 171.00 171.00 177.00 177.00 183.00 183.00 191.00 191.00 199.00
700 700 158.00 164.00 164.00 171.00 171.00 177.00 177.00 183.00 183.00 191.00 191.00 199.00
750 750 177.00 183.00 183.00 189.00 189.00 196.00 196.00 203.00 203.00 211.00 211.00 221.00
800 800 177.00 183.00 183.00 189.00 189.00 196.00 196.00 203.00 203.00 211.00 211.00 221.00
850 850 194.00 202.00 202.00 208.00 208.00 216.00 216.00 224.00 224.00 233.00 233.00 244.00
900 900 194.00 202.00 202.00 208.00 208.00 216.00 216.00 224.00 224.00 233.00 233.00 244.00
950 950 213.00 221.00 221.00 229.00 229.00 236.00 236.00 244.00 244.00 255.00 255.00 258.00
1000 A00 213.00 221.00 221.00 229.00 229.00 236.00 236.00 244.00 244.00 255.00 255.00 258.00
1050 A50 232.00 239.00 239.00 247.00 247.00 257.00 257.00 266.00 266.00 277.00 277.00 290.00
1100 B00 232.00 239.00 239.00 247.00 247.00 257.00 257.00 266.00 266.00 277.00 277.00 290.00
1150 B50 250.00 258.00 258.00 268.00 268.00 277.00 277.00 286.00 286.00 299.00 299.00 311.00
1200 C00 250.00 258.00 258.00 268.00 268.00 277.00 277.00 286.00 286.00 299.00 299.00 311.00

Article number - = B010101 x y


L [mm]
800 850 900 950 1000 1050 1100 1150 1200 1250 1300
x=
800 850 900 950 A00 A50 B00 B50 C00 C50 D00
H [mm] y= Price B
200 200 86.08 89.22 89.22 93.92 93.92 97.04 97.04 100.00 100.00 103.00 103.00
250 250 108.00 113.00 113.00 117.00 117.00 122.00 122.00 127.00 127.00 131.00 131.00
300 300 108.00 113.00 113.00 117.00 117.00 122.00 122.00 127.00 127.00 131.00 131.00
350 350 131.00 136.00 136.00 142.00 142.00 147.00 147.00 153.00 153.00 158.00 158.00
400 400 131.00 136.00 136.00 142.00 142.00 147.00 147.00 153.00 153.00 158.00 158.00
450 450 153.00 160.00 160.00 166.00 166.00 172.00 172.00 180.00 180.00 186.00 186.00
500 500 153.00 160.00 160.00 166.00 166.00 172.00 172.00 180.00 180.00 186.00 186.00
550 550 175.00 183.00 183.00 191.00 191.00 199.00 199.00 205.00 205.00 213.00 213.00
600 600 175.00 183.00 183.00 191.00 191.00 199.00 199.00 205.00 205.00 213.00 213.00
650 650 199.00 207.00 207.00 216.00 216.00 224.00 224.00 233.00 233.00 241.00 241.00
700 700 199.00 207.00 207.00 216.00 216.00 224.00 224.00 233.00 233.00 241.00 241.00
750 750 221.00 232.00 232.00 239.00 239.00 249.00 249.00 258.00 258.00 268.00 268.00
800 800 221.00 232.00 232.00 239.00 239.00 249.00 249.00 258.00 258.00 268.00 268.00
850 850 244.00 255.00 255.00 265.00 265.00 274.00 274.00 285.00 285.00 296.00 296.00
900 900 244.00 255.00 255.00 265.00 265.00 274.00 274.00 285.00 285.00 296.00 296.00
950 950 258.00 279.00 279.00 290.00 290.00 301.00 301.00 319.00 319.00 322.00 322.00
1000 A00 258.00 279.00 279.00 290.00 290.00 301.00 301.00 319.00 319.00 322.00 322.00
1050 A50 290.00 302.00 302.00 315.00 315.00 327.00 327.00 338.00 338.00 351.00 351.00
1100 B00 290.00 302.00 302.00 315.00 315.00 327.00 327.00 338.00 338.00 351.00 351.00
1150 B50 311.00 326.00 326.00 338.00 338.00 352.00 352.00 365.00 365.00 377.00 377.00
1200 C00 311.00 326.00 326.00 338.00 338.00 352.00 352.00 365.00 365.00 377.00 377.00

Prices
JS 250 MCS (**) LOA (**)
Article number Article number Price Article number Price
All articles B010501001100 12.52 ˜ B010501003101 8.38
(**) MCS: See page 247; LOA: See page 248

B01 JS 250 2/3 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

B01 240

Multi-leaf dampers
JS 250
D = 140 mm for outdooor mechanism
10

30

30
H
L

110 110

30
30

100 100

H H

200 < H > 279 280 < H > 299


300 379 380 399
400 479 480 499
... ... ... ...

B01 JS 250 3/3 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

241
B01
Multi-leaf dampers
JS 251
Multi-leaf dampers in galvanized steel.
Application
¾ For airstream regulation in ventilation and airconditioning systems

Material
¾ Galvanized steel blades, frame, and round axle
¾ Aluminium gears
¾ Polyamid bearings

Composition
¾ Galvanized steel aerodynamic designed regulation blades of 165 mm width containing aluminium
gears for simultanious counter-rotating operation of the damper
¾ Galvanized steel axle of Ø 12 mm and length 100 mm mounted on one of the above blades, wich
extends 67 mm outside the damperflanges. Axle with borehole at its end to easily mount axle
extension LOA 100 M or LOA 150 M (upon request), when a longer axle is required.
¾ Galvanized steel housing with depth of 175mm and flange of 30mm, made out of 2 vertical panels
with polyamid bearings and 2 horizontal panels, all welded together
¾ All dampers are made to measure. To obtain the exact height of the damper when in-between
sizes are ordered, the upper and lower frame will be bended towards or away from the middle of
the damper (see drawing), to make a execellent fit with as much as possible standard fitted blades.
Due to this fact the free area of the damper can become less than the opening of the LXH dimension.
Mounting
¾ To be mounted between rectangular ducts with flanges of 30 mm
¾ To be surface mounted on wall, floor or ceiling

Accessories
¾ Manual control handle with fixing system type MCS-251/255
¾ Horizontal sealing between the valves available upon request (+10%)
¾ Mounted axle extensions type LOA 100 M, LOA 150 M
¾ Extra axle available upon request
¾ Square axle end of 9 X 9 mm type SQE
¾ Actuators BELIMO
¾ Alternative bearings:
¾ PTFE bearings for low and high temperature applications type TBS (from -50°C to 200°C)
¾ Brass bearings for high temperature applications type MBS (up to 250°C)
¾ Ball bearings for high temperature applications at high pressure type BBS (up to 80°C and
2500Pa)
¾ Horizontal mounted coupling system type HVM
¾ Alternative outer-mechanism (for high temperature applications)
¾ Counter-rotating blades (+20%)
B
¾ Parallel moving blades (+20%)
¾ Reinforced frames (+5%)
¾ Multi-leaf damper with vertical blades (+15%)
¾ Alternative construction materials
¾ Aluminium (x3.5)
¾ Stainless steel (INOX304) (x5.6)
¾ Stainless steel (INOX316) (x6.75)
¾ Aluminium blades with galvanized steel frame (x1.75)
¾ Version ATEX available upon request

Prices
Article number - = B010301 x y
L [mm]
300 400 500 600 700 800 900 1000 1200 1400 1600 1800 2000
x=
300 400 500 600 700 800 900 A00 C00 E00 G00 I00 K00
H [mm] y= Price
345 345 82.96 87.66 92.34 97.04 102.00 108.00 113.00 117.00 130.00 139.00 150.00 161.00 174.00
510 510 106.00 111.00 117.00 124.00 130.00 136.00 144.00 150.00 164.00 178.00 193.00 205.00 221.00
675 675 128.00 135.00 142.00 149.00 158.00 166.00 174.00 182.00 199.00 216.00 233.00 249.00 268.00
840 840 152.00 160.00 167.00 175.00 185.00 194.00 203.00 214.00 235.00 254.00 274.00 294.00 315.00
1005 A05 174.00 183.00 193.00 202.00 213.00 224.00 235.00 246.00 269.00 291.00 316.00 338.00 362.00
1170 B70 197.00 207.00 218.00 227.00 239.00 254.00 266.00 279.00 305.00 330.00 357.00 382.00 408.00
1335 D35 221.00 232.00 243.00 254.00 268.00 282.00 296.00 310.00 340.00 368.00 399.00 426.00 455.00
1500 F00 243.00 255.00 268.00 280.00 296.00 311.00 327.00 343.00 376.00 407.00 440.00 471.00 502.00
1665 G65 266.00 279.00 293.00 307.00 324.00 341.00 358.00 376.00 412.00 444.00 482.00 515.00 549.00
1830 I30 290.00 304.00 318.00 333.00 352.00 371.00 388.00 407.00 446.00 484.00 523.00 559.00 596.00
1995 J95 311.00 329.00 344.00 360.00 380.00 399.00 419.00 440.00 482.00 521.00 565.00 604.00 643.00

Prices
JS 251 MCS (**) LOA (**)
Article number Article number Price Article number Price
All articles B010501001200 12.52 ˜ B010501003101 8.38
(**) MCS: See page 247; LOA: See page 248

B01 JS 251 1/2 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

B01 242

Multi-leaf dampers
JS 251
175 175 175
10
30

30
30
30

165 165

H H
H

L 345 < H > 477 478 < H > 509


510 642 643 674
675 807 808 839
... ... ... ...

B01 JS 251 2/2 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

243
B01
Air tight multi-leaf dampers
JL 254
Air tight multi-leaf dampers in galvanized steel classified DIN EN 1751-4.
Application
¾ For airstream regulation in ventilation and airconditioning systems

Material
¾ Galvanized steel blades, frame, and round axle
¾ Air tight sealings between the blades and the gears
¾ Aluminium gears
¾ Airtight polyamid bearings max for temperature ranges upto 80°C

Composition
¾ Galvanized steel aerodynamic designed regulation blades of 100 mm width containing aluminium
gears for simultanious counter-rotating operation of the damper
¾ Air tight sealings between the blades and the gears classified DIN EN 1751-4
¾ Galvanized steel axle of Ø 12 mm and length 100 mm mounted on one of the above blades, wich
extends 67 mm outside the damperflanges. Axle with borehole at its end to easily mount axle
extension LOA 100 M or LOA 150 M (upon request), when a longer axle is required.
¾ Galvanized steel housing with depth of 110 mm and flange of 30mm, made out of 2 vertical panels
with air-tight polyamid bearings and 2 horizontal panels, all welded together
¾ All dampers are made to measure. To obtain the exact height of the damper when in-between
sizes are ordered, the upper and lower frame will be bended towards or away from the middle of
the damper(see drawing), to make a execellent fit with as much as possible standard fitted blades.
Due to this fact the free area of the damper can become less than the opening of the LXH dimension.
Mounting
¾ To be mounted between rectangular ducts with flanges of 30 mm
¾ To be surface mounted on wall, floor or ceiling

Accessories
¾ Manual control handle with fixing system type MCS-250/254
¾ Mounted axle extensions type LOA 100 M, LOA 150 M
¾ Extra axle available upon request
¾ Square axle end of 9 x 9 mm type SQE
¾ Actuators BELIMO
¾ Alternative bearings:
¾ PTFE bearings for low and high temperature applications type TBS (from -50°C to 200°C)
¾ Brass bearings for high temperature applications type MBS (up to 250°C)
¾ Ball bearings for high temperature applications at high pressure type BBS (up to 80°C and
2500Pa)
¾ Air tight silicone sealings (for high temperature applications upto 250°C) +10%
¾ Horizontal mounted coupling system type HVM
B
¾ Alternative outer-mechanism (for high temperature applications) (Dimension D=140 mm instead
of 110 mm)
¾ Counter-rotating blades (+20%)
¾ Parallel moving blades (+20%)
¾ Reinforced frames (+5%)
¾ Multi-leaf damper with vertical blades (+15%)
¾ Alternative construction materials
¾ Aluminium (x2.25)
¾ Stainless steel (INOX304) (x3.75)
¾ Stainless steel (INOX316) (x4.3)
¾ Aluminium blades with galvanized steel frame (x1.75)
¾ Version ATEX available upon request

B01 JL 254 1/3 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

B01 244

Air tight multi-leaf dampers


JL 254
Prices
Article number - = B010201 x y
L [mm]
200 250 300 350 400 450 500 550 600 650 700
x=
200 250 300 350 400 450 500 550 600 650 700
H [mm] y= Price
200 200 130.00 134.00 134.00 138.00 138.00 141.00 141.00 146.00 146.00 152.00 152.00
250 250 168.00 173.00 173.00 178.00 178.00 182.00 182.00 188.00 188.00 194.00 194.00
300 300 168.00 173.00 173.00 178.00 178.00 182.00 182.00 188.00 188.00 194.00 194.00
350 350 207.00 211.00 211.00 217.00 217.00 223.00 223.00 230.00 230.00 238.00 238.00
400 400 207.00 211.00 211.00 217.00 217.00 223.00 223.00 230.00 230.00 238.00 238.00
450 450 245.00 251.00 251.00 258.00 258.00 264.00 264.00 271.00 271.00 280.00 280.00
500 500 245.00 251.00 251.00 258.00 258.00 264.00 264.00 271.00 271.00 280.00 280.00
550 550 283.00 290.00 290.00 297.00 297.00 306.00 306.00 313.00 313.00 323.00 323.00
600 600 283.00 290.00 290.00 297.00 297.00 306.00 306.00 313.00 313.00 323.00 323.00
650 650 322.00 329.00 329.00 338.00 338.00 347.00 347.00 356.00 356.00 367.00 367.00
700 700 322.00 329.00 329.00 338.00 338.00 347.00 347.00 356.00 356.00 367.00 367.00
750 750 360.00 369.00 369.00 377.00 377.00 388.00 388.00 398.00 398.00 409.00 409.00
800 800 360.00 369.00 369.00 377.00 377.00 388.00 388.00 398.00 398.00 409.00 409.00
850 850 399.00 408.00 408.00 418.00 418.00 428.00 428.00 440.00 440.00 453.00 453.00
900 900 399.00 408.00 408.00 418.00 418.00 428.00 428.00 440.00 440.00 453.00 453.00
950 950 437.00 449.00 449.00 459.00 459.00 471.00 471.00 482.00 482.00 497.00 497.00
1000 A00 437.00 449.00 449.00 459.00 459.00 471.00 471.00 482.00 482.00 497.00 497.00
1050 A50 475.00 488.00 488.00 500.00 500.00 511.00 511.00 523.00 523.00 541.00 541.00
1100 B00 475.00 488.00 488.00 500.00 500.00 511.00 511.00 523.00 523.00 541.00 541.00
1150 B50 514.00 528.00 528.00 539.00 539.00 552.00 552.00 565.00 565.00 584.00 584.00
1200 C00 514.00 528.00 528.00 539.00 539.00 552.00 552.00 565.00 565.00 584.00 584.00

Article number - = B010201 x y


L [mm]
750 800 850 900 950 1000 1050 1100 1150 1200
x=
750 800 850 900 950 A00 A50 B00 B50 C00
H [mm] y= Price B
200 200 156.00 156.00 160.00 160.00 165.00 165.00 170.00 170.00 175.00 175.00
250 250 200.00 200.00 205.00 205.00 213.00 213.00 220.00 220.00 226.00 226.00
300 300 200.00 200.00 205.00 205.00 213.00 213.00 220.00 220.00 226.00 226.00
350 350 245.00 245.00 252.00 252.00 259.00 259.00 268.00 268.00 275.00 275.00
400 400 245.00 245.00 252.00 252.00 259.00 259.00 268.00 268.00 275.00 275.00
450 450 289.00 289.00 297.00 297.00 306.00 306.00 316.00 316.00 325.00 325.00
500 500 289.00 289.00 297.00 297.00 306.00 306.00 316.00 316.00 325.00 325.00
550 550 334.00 334.00 344.00 344.00 354.00 354.00 364.00 364.00 374.00 374.00
600 600 334.00 334.00 344.00 344.00 354.00 354.00 364.00 364.00 374.00 374.00
650 650 379.00 379.00 389.00 389.00 401.00 401.00 412.00 412.00 424.00 424.00
700 700 379.00 379.00 389.00 389.00 401.00 401.00 412.00 412.00 424.00 424.00
750 750 423.00 423.00 436.00 436.00 449.00 449.00 460.00 460.00 474.00 474.00
800 800 423.00 423.00 436.00 436.00 449.00 449.00 460.00 460.00 474.00 474.00
850 850 468.00 468.00 482.00 482.00 495.00 495.00 509.00 509.00 523.00 523.00
900 900 468.00 468.00 482.00 482.00 495.00 495.00 509.00 509.00 523.00 523.00
950 950 513.00 513.00 528.00 528.00 544.00 544.00 558.00 558.00 574.00 574.00
1000 A00 513.00 513.00 528.00 528.00 544.00 544.00 558.00 558.00 574.00 574.00
1050 A50 557.00 557.00 573.00 573.00 590.00 590.00 609.00 609.00 625.00 625.00
1100 B00 557.00 557.00 573.00 573.00 590.00 590.00 609.00 609.00 625.00 625.00
1150 B50 602.00 602.00 619.00 619.00 638.00 638.00 664.00 664.00 675.00 675.00
1200 C00 602.00 602.00 619.00 619.00 638.00 638.00 664.00 664.00 675.00 675.00

Prices
JL 254 MCS (**) LOA (**)
Article number Article number Price Article number Price
All articles B010501001100 12.52 ˜ B010501003101 8.38
(**) MCS: See page 247; LOA: See page 248

B01 JL 254 2/3 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

B01 245

Air tight multi-leaf dampers


JL 254
D = 140 mm for outdoor mechanism
10

30

30
H
L

110 110

30
30

100 100

H H

200 < H > 279 280 < H > 299


300 379 380 399
400 479 480 499
... ... ... ...

B01 JL 254 3/3 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

246
B01
Air tight multi-leaf dampers
JL 255
Air tight multi-leaf dampers in galvanized steel classified DIN EN 1751-4.
Application
¾ For airstream regulation in ventilation and airconditioning systems

Material
¾ Galvanized steel blades, frame, and round axle
¾ Air tight sealings between the blades and the gears
¾ Aluminium gears
¾ Air-tight polyamid bearings for temperature ranges upto 80°C

Composition
¾ Galvanized steel aerodynamic designed regulation blades of 165 mm width containing aluminium
gears for simultanious counter-rotating operation of the damper
¾ Air tight sealings between the blades and the gears classified DIN EN 1751-4
¾ Galvanized steel axle of Ø 12 mm and length 100 mm mounted on one of the above blades, wich
extends 67 mm outside the damperflanges. Axle with borehole at its end to easily mount axle
extension LOA 100 M or LOA 150 M (upon request), when a longer axle is required.
¾ Galvanized steel housing with depth of 175 mm and flange of 30mm, made out of 2 vertical panels
with air tight polyamid bearings and 2 horizontal panels, all welded together
¾ All dampers are made to measure. To obtain the exact height of the damper when in-between
sizes are ordered, the upper and lower frame will be bended towards or away from the middle of
the damper(see drawing), to make a execellent fit with as much as possible standard fitted blades.
Due to this fact the free area of the damper can become less than the opening of the LXH dimension.
Mounting
¾ To be mounted between rectangular ducts with flanges of 30 mm
¾ To be surface mounted on wall, floor or ceiling

Accessories
¾ Manual control handle with fixing system type MCS-251/255
¾ Mounted axle extensions type LOA 100 M, LOA 150 M
¾ Extra axle available upon request
¾ Square axle end of 9 x 9 mm, type SQE
¾ Actuators BELIMO
¾ Alternative bearings:
¾ PTFE bearings for low and high temperature applications type TBS (from -50°C to 200°C)
¾ Brass bearings for high temperature applications type MBS (up to 250°C)
¾ Ball bearings for high temperature applications at high pressure type BBS (up to 80°C and
2500Pa)
¾ Air tight silicone sealings (for high temperatures upto 250°C) +10%
¾ Horizontal mounted coupling system type HVM
B
¾ Alternative outer-mechanism (for high temperature applications)
¾ Counter-rotating blades (+20%)
¾ Parallel moving blades (+20%)
¾ Reinforced frames (+5%)
¾ Multi-leaf damper with vertical blades (+15%)
¾ Alternative construction materials
¾ Aluminium (x 2.25)
¾ Stainless steel (INOX304) (x 3.75)
¾ Stainless steel (INOX316) (x 4.3)
¾ Aluminium blades with galvanized steel frame (x 1.75)
¾ Version ATEX available upon request

Prices
Article number - = B010401 x y
L [mm]
300 400 500 600 700 800 900 1000 1200 1400 1600
x=
300 400 500 600 700 800 900 A00 C00 E00 G00
H [mm] y= Price
345 345 165.00 170.00 178.00 185.00 192.00 200.00 208.00 216.00 232.00 248.00 264.00
510 510 214.00 223.00 230.00 239.00 249.00 258.00 268.00 278.00 299.00 318.00 340.00
675 675 264.00 274.00 284.00 293.00 306.00 318.00 329.00 341.00 366.00 391.00 415.00
840 840 313.00 325.00 337.00 348.00 361.00 376.00 391.00 405.00 434.00 462.00 491.00
1005 A05 363.00 376.00 389.00 404.00 418.00 436.00 452.00 468.00 501.00 533.00 568.00
1170 B70 412.00 427.00 443.00 458.00 475.00 494.00 513.00 530.00 568.00 605.00 644.00
1335 D35 463.00 479.00 495.00 513.00 533.00 554.00 574.00 595.00 637.00 678.00 721.00
1500 F00 513.00 532.00 549.00 568.00 590.00 612.00 635.00 657.00 705.00 749.00 797.00
1665 G65 562.00 583.00 602.00 622.00 647.00 672.00 697.00 721.00 772.00 822.00 874.00
1830 I30 613.00 634.00 656.00 678.00 704.00 732.00 758.00 784.00 841.00 893.00 950.00
1995 J95 670.00 686.00 710.00 733.00 762.00 790.00 819.00 848.00 909.00 966.00 1,027.00

Prices
JL 255 MCS (**) LOA (**)
Article number Article number Price Article number Price
All articles B010501001200 12.52 ˜ B010501003101 8.38
(**) MCS: See page 247; LOA: See page 248

B01 JL 255 1/2 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

B01 247

Air tight multi-leaf dampers


JL 255
175
10

30

30
H
L

175 175

30
30

165 165

H H

345 < H > 477 478 < H > 509


510 642 643 674
675 807 808 839
... ... ... ...

MCS
Manual controls with fixing system
Manual Contro handles with fixing system for muli-leaf dampers
Application
¾ Manual control handles MCS 250E with fixing system for JS 250E KIT assembled multi-leaf dampers
of width 120mm
¾ Manual control handles MCS 250/254 with fixing system for JS 250 or JL254 multi-leaf dampers of
width 110mm
¾ Manual control handles MCS 251/255 with fixing system for JS 251 or JL255 multi-leaf dampers of
width 175mm
Prices
Type For multi-leaf damper type Article number Price
MCS
MCS 250K JS 250E B010501001000 12.52 ˜
MCS 250/254 JS250 / JL254 B010501001100 12.52 ˜
MCS 251/255 JS251 / JL255 B010501001200 12.52 ˜
˜ R Stock product Zaventem, except sales

B01 JL 255, MCS 2/2 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

248
Axle extensions for multi-leaf B01
dampers
LOA
Axle extensions Ø12 mm for multi-leaf dampers
Application
¾ Axle extensions Ø12 mm for multi-leaf dampers
¾ Available in lengths 100, 150 and 200 mm
¾ Premounted type LOA xxx M or separately type LOA xxx

Prices
Type Length Mounted Article number Price
[mm] LOA
LOA 100 100 No B010501003100 5.70 ˜
LOA 100 M 100 Yes B010501003101 8.38
LOA 150 150 No B010501003150 6.00 ˜
LOA 150 M 150 Yes B010501003151 8.38
LOA 200 200 No B010501003200 6.94 ˜
˜ R Stock product Zaventem, except sales

B01 LOA 1/1 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

249
Circular connection piece for B01
dampers
CCP
Circular connection piece for connection of circular ducts on multi-leaf dampersTo be ordered per
piece with multi-leaf damper
Application
¾ To be applied when multi-leaf dampers are connected in between 2 circular ducts(2 connection
pieces needed)
¾ To be applied when circular ducts are connected to a wall mounted damper (1piece needed)
¾ Made for connection on dampers with flanges of 30 mm according the drawingand for damper
sizes LXH according table.
Material
¾ Galvanized steel with EPDM seal

Composition
¾ Flat edged sheet steel with round plug with EPDM rubber gasket

Mounting
¾ To be mounted on JS250, JS251, JL254 of JL255 Multi-leaf damper

Other available products


¾ Versions in aluminum, Stainless steel 304 (V2A) or Stainless steel 316 (V4A) withor without rubber
seals available on request
Prices
Type L hole H hole For multi-leaf damper type Article number Price
[mm] [mm] CCP
CCP DIA 200 200 200 JS250 / JL254 - JS251 / JL255 B010501200000 43.74
CCP DIA 250 250 250 JS250 / JL254 - JS251 / JL255 B010501250000 46.02
CCP DIA 315 350 350 JS250 / JL254 - JS251 / JL255 B010501315000 50.46
CCP DIA 355 400 400 JS250 / JL254 - JS251 / JL255 B010501355000 52.66
CCP DIA 400 400 400 JS250 / JL254 - JS251 / JL255 B010501400000 53.98
CCP DIA 450 450 450 JS250 / JL254 - JS251 / JL255 B010501450000 56.88
CCP DIA 500 500 500 JS250 / JL254 - JS251 / JL255 B010501500000 59.40
CCP DIA 560 600 600 JS250 / JL254 - JS251 / JL255 B010501560000 67.64
CCP DIA 630 650 650 JS250 / JL254 - JS251 / JL255 B010501630000 75.32
CCP DIA 710 750 750 JS250 / JL254 - JS251 / JL255 B010501710000 82.56
CCP DIA 800 800 800 JS250 / JL254 - JS251 / JL255 B010501800000 95.64
CCP DIA 900 900 900 JS250 / JL254 - JS251 / JL255 B010501900000 106.00
CCP DIA 1000 1000 1000 JS250 / JL254 - JS251 / JL255 B01050A000000 116.00 B
CCP DIA 1120 1150 1150 JS250 / JL254 - JS251 / JL255 B01050B520000 130.00

Dimensions
CCP LXH [mm] DIA [mm]

30

30
200 200 X 200 200
250 250 X 250 250
315 350 X 350 315
355 400 X 400 355
H

400 400 X 400 400


450 400 X 400 450
500 500 X 500 500
560 600 X 600 560
630 650 X 650 630 L
710 750 X 750 710
800 800 X 800 800
900 900 X 900 900
1000 1000 X 1000 1000
1120 1150 X 1150 1120

B01 CCP 1/1 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

250
B01
Lateral actuator mounting plate
AMP
Actuator for servomotor mounting in the air flow
Application
¾ For mounting of actuators inside ducts due to lack of space.
¾ For installation of dampers in shafts
¾ For mounting of dampers in wall openings
¾ In settings where maximum transmission is required

Material
¾ Mounting plate, axles and transmission in galvanized steel
¾ Bearing in PTFE

Mounting
¾ Only available when ordered, premounted on standard dampers
¾ Damper flange will always be made 38 mm at multileaf damper at the side of the mounting plate

Prices
¾ Standard type for BELIMO actuators: 180€
¾ The type of actuator should always be specified when ordered
¾ Mounting plates for other actuators available upon request

Mounting example

TBS
PTFE bearings for multi-leaf dampers
¾ PTFE bearings for multi-leaf dampers
¾ For low and high temperature applications (-50°C to 200°C)
¾ Article must be multiplied with the blade quantity
Prices
Type Mounted Article number Price
TBS
TBS Yes B010501006000 3.24

B01 AMP, TBS 1/1 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

251
Brass bearings for multi-leaf B01
dampers
MBS
¾ Brass bearings for multi-leaf dampers
¾ For high temperature applications (up to 250°C)
¾ Article must be multiplied with the blade quantity
Prices
Type Mounted Article number Price
MBS
MBS Yes B010501007000 3.24

BBS
Ball bearings for multi-leaf dampers
¾ Ball bearings for multi-leaf dampers
¾ For high temperature and high pressure applications (up to 200°C and 2500Pa)
¾ Article must be multiplied with the blade quantity
Prices
Type Mounted Article number Price
BBS
BBS Yes B010501008000 9.02

RVK 8371
Rubber sealing for multi-leaf dampers
¾ Rubber profile for multi-leaf dampers
¾ Per meter
¾ To be inserted within the hollow profile of the blades
¾ Must be multiplied with the quantity of blades and blade lengths
Prices
Type Article number Price
RVK 8371
RVK8371 B010501011000 1.08 ˜
˜ R Stock product Zaventem, except sales

B01 MBS, BBS, RVK 8371 1/1 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

252
B01
Rubber sealings for dampers
RVK 8372
¾ Rubber profile for multi-leaf dampers
¾ Per meter
¾ To be mounted on the top of the top blade of the damper
¾ Must be multiplied with the blade length
Prices
Type Article number Price
RVK 8372
RVK8372 B010501010000 2.68 ˜
˜ R Stock product Zaventem, except sales

B01 RVK 8372 1/1 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

253
Multi-leaf dampers with high B01
temperature resistance
JS 251BS+ML
Multi-leaf dampers in galvanized steel
Equipped with outer mechanism and brass bearings
Application
¾ For airstream regulation in ventilation and airconditioning systems
¾ Temperature resistant applications up to 250°C
¾ Smoke & heat extraction installations

Material
¾ Galvanized steel blades, frame, and square axle
¾ Outer mechanism
¾ Air-tight brass bearings for temperature ranges upto 250°C

Composition
¾ Galvanized steel aerodynamic designed regulation blades of 165 mm width
¾ Galvanized steel square axle
¾ Galvanized steel housing with depth of 175 mm and flange of 30mm, made out of 2 vertical panels
with air tight brass bearings and 2 horizontal panels, all welded together
¾ All dampers are made to measure. To obtain the exact height of the damper when in-between
sizes are ordered, the upper and lower frame will be bended towards or away from the middle of
the damper(see drawing), to make a execellent fit with as much as possible standard fitted blades.
Due to this fact the free area of the damper can become less than the opening of the LXH dimension.
Mounting
¾ To be mounted between rectangular ducts with flanges of 30 mm
¾ To be surface mounted on wall, floor or ceiling

Prices
¾ Prices on demand

175
30 10

30
B
H

175 175

30
30

165 165

H H

345 < H > 477 478 < H > 509


510 642 643 674
675 807 808 839
... ... ... ...

B01 JS 251BS+ML 1/1 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

254
Airthight multi-leaf dampers with B01
high temperature resistance
JL 255BS+ML+SD
Air tight multi-leaf dampers in galvanized steel classified DIN EN 1751-4.
Equipped with outer mechanism, brass bearings and silicone sealings.
Application
¾ For airstream regulation in ventilation and airconditioning systems
¾ Temperature resistant applications up to 250°C
¾ Smoke & heat extraction installations

Material
¾ Galvanized steel blades, frame, and square axle
¾ Air tight sealings between the blades and sides of the blades
¾ Outer mechanism
¾ Air-tight brass bearings for temperature ranges upto 250°C

Composition
¾ Galvanized steel aerodynamic designed regulation blades of 165 mm width
¾ Air tight sealings between the blades and the gears classified DIN EN 1751-4
¾ Galvanized steel square axle
¾ Galvanized steel housing with depth of 175 mm and flange of 30mm, made out of 2 vertical panels
with air tight brass bearings and 2 horizontal panels, all welded together
¾ All dampers are made to measure. To obtain the exact height of the damper when in-between
sizes are ordered, the upper and lower frame will be bended towards or away from the middle of
the damper(see drawing), to make a excellent fit with as much as possible standard fitted blades.
Due to this fact the free area of the damper can become less than the opening of the LXH dimension.
Mounting
¾ To be mounted between rectangular ducts with flanges of 30 mm
¾ To be surface mounted on wall, floor or ceiling

Prices
¾ Prices on demand

175
10
30

30
B
H

B01 JL 255BS+ML+SD 1/1 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

255
Motorized smoke control B01
dampers
ESAS
Rectangular smoke control damper ESAS is specially designed to use in single fire compartment
applications as a closing or as an opening damper for smoke extract purposes. ESAS is fulfilling the
european product standard EN12101-8 requirements for single compartment applications and it is
CE marked. The product has been tested according to EN 1366-10 fulfilling fireclass E 120 with pressure
class 500 Pa and temperature class 600 °C. ESAS dampers are suitable both for automatically by a
fire alarm activated systems (AA) and manually, after the fire has started, by fire fighter acated systems
(MA), 25 min open / close. ESAS smoke control damper is designed so, that opening or closing can be
made even 25 minutes after the fire has started, in 600 °C. Factory mounted electrical actuator is
placed inside fireresistant calcium-silicate box.
Application
¾ ESAS has been designed to use in single fire compartment applications as a closing or as an opening
damper for smoke extract purposes.
Material
¾ Galvanized steel frame and damper blades
¾ Damper blades of ESAS are insulated with stone wool insulation
¾ Smoke control damper ESAS is always delivered with factory mounted electrical actuator 24 V or
230 V placed inside calcium-silicate box.
Composition
¾ Galvanized steel frame and damper blades
¾ Standard delivered with Flange joint of 32 mm, slip joint of 230 mm available upon request
¾ Insulated damper blades with stone wool insulation
¾ Smoke control damper ESAS is always delivered with factory mounted electrical actuator 24 V or
230 V inside calcium-silicate box
¾ Smoke control damper has two safety positions open or closed
¾ Smoke control damper is activated to transfer to safety position automatically by smoke detection
or manually by switch used by fire fighters
¾ Electrical actuator has 2 free auxiliary switches for open / close position indication

Mounting
¾ Installation instructions (see download area) has to be followed to be able to fulfill fire classification.
¾ The duct outlet must be placed so that the smoke extraction damper is protected from water
coming from outside as well as ice and snow that could hinder the opening of the damper
¾ The ductwork section between the smoke extraction damper and duct outlet must be designed
and insulated so that the fire resistance and tightness requirements are met
¾ Also take account of possible condensation
¾ By design phase and installation work it is very important to notice, that all cable system with
connection boxes has to be done by fire resistant products. Electrical actuator changes the damper
position from open or close with transfer time not more than 60 s. If the electricity is cut off, damper
blade will remain in its position B
¾ Flow direction has no affect to the function of the damper

Accessories
¾ ESAS dampers are standardly delivered with flange joint of 32 mm. Upon request also a slip joint
of 20 mm is possible
¾ Smoke dampers can be equipped with circular connection on both sides of the damper
¾ Protection grid FNR can be supplied on the damper

Certification
¾ Fire tested and CE marked MPA No. 0761-CPD-0288 according the harmonised product standard
EN 12101-8
¾ The smoke extraction damper fulfill the requirements of leakage class 2 according to EN 1751.
¾ The damper casing fulfills the requirments of leakage class B according to EN 1751.
¾ Pressure drop across a closed damper may amount to 2500 Pa
2
¾ Heat transfer coefficie U = 3,7 W/m K
¾ Fire class according to EN 13501-4: E600 120 (ve i <-> o) 500C300 MAsingle
¾ Fullfills the requirements for MA clas for opening / closing (25 min, 600 °C)
¾ Suitable both for AA and MA smoke control systems

Other available products


¾ ESAR circular smoke dampers with circular blade

Prices
For prices please check our website www.sigairhandling.com

B01 ESAS 1/3 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

B01 256
Motorized smoke control
dampers
ESAS

Dimensions
L [mm] 200 250 300 350 400 450 500 600 700 800 900 1000 1100 1200
H [mm] 200 250 300 350 400 450 500 600 700 800 900 1000 1100 1200
M [mm] 134 284 334 484 534 484 534 484 534 684 734
O [mm] 134 84 134 84 134 284 334 484 534 484 534
x [mm] 120 145 170 195 120 145 170 120 170 120 170 120 170 120
n(spacing )[mm] 0 0 0 0 1 1 1 2 2 3 3 4 4 5

Electrical wiring diagram


L1-L2 open (90°)
L1-L3 closed (0°)

N
T L1
~ AC 230 V
AC 24 V
– + DC 24 V B
Closed (<3°) Open (>87°)
Contact between Contact between
S1-S2 S4-S6

1 2 3 S1 S2 S3 S4 S5 S6

<3° <87°

Actuator electrical data


U [V] Max Power [W] Power for wire size
24C AC/DC 0,5W / 12W 18VA
230V AC 0,5W / 8W 15VA

Remarks
¾ Wiring of the actuator has to be done inside the fire resitant calcium-silicate box, since the cable delivered with the actuator is non fire resistant.
The wiring of ESAS smoke control damper must always be done using fire resistant cables and switch boxes in order to guarantee the damper’s
operation in case of fire

B01 ESAS 2/3 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

B01 257
Motorized smoke control
dampers
ESAS
Noise level in the duct

Correction factors Pressure drop


Correction of sound power per
octave bands Koct
Frequency band 125 250 500 1000 2000 4000 8000
Correction Koct -3 -5 -11 -15 -18 -21 -33
Lwoct = Lwt +
Koct

Symbols and specifications


¾ v = Flow velocity in m/s
¾ LWokt = Sound power level in the duct in dB
¾ LWt = Sound power level in dB
¾ Kokt = Correction factor in dB
¾ Δps = Static pressure drop in Pa

B01 ESAS 3/3 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

258
B02

Constant volume control dampers (CAV)


KVR-R P.259 KVR-R HP P.262 VRS P.265 VRRK P.266

˜˜ ˜˜

¾ Circular ¾ Circular ¾ Circular ¾ Rectangular


¾ Flame retardant PVC ¾ Flame retardant PVC ¾ Galvanized steel ¾ Galvanized steel
¾ Standard ¾ High pressure ¾ 50-1000 Pa ¾ 50-1000 Pa
¾ 50-250 Pa ¾ 150-600 Pa

˜ R Stock product Zaventem, except sales


˜ R Stock product local warehouses, except sales

www.sigairhandling.be
B - Valves & volume control dampers

259
Adjustable constant air volume B02
dampers
KVR-R
Constant volume control dampers made of fire retardant plastics. The range covers an air flow range
between 15 up to 700 m³/h within a pressure range from 50 up to 250 Pa. Air flow can easily be
adjusted within the airflow range of each damper.
Application
¾ To obtain constant air volumes in ventilation and air conditioning systems within a pressure range
between 50 and 250Pa
¾ For air supply or exhaust duct systems
¾ Maximum working temperature 60°C

Composition
¾ Valve and piston made out of fire retardant plastics M1
¾ Body in fire retardant plastics M1 or steel for diameter 150 to 250
¾ Stainless steel calibrated spring
¾ Rubber air-tight sealing

Mounting
¾ For mounting inside round ducts
¾ Horizontal as well as vertical mounting applicable
¾ For horizontal mounting, the BAS marking has to be at the bottom
¾ To be installed in accordance with the correct air flow direction
¾ To be installed in the air intake at a minimum distance of three times the diameter of the duct
starting from the air intake grilles and at the same distance from places with a high degree of
turbulence in the duct, such as branches, bends,….
¾ To be installed in the air outtake at a minimum distance of one time the diameter of the duct
starting from the extraction grilles and at the same distance from places with a high degree of
turbulence in the duct, such as branches, bends,….
¾ The volume control damper has to be easily accessible for maintenance

Accessories
¾ Screw driver
or bit Torx
T10 for unsc­
rewing the
screw for
adjusting the
air flow rate
of the regula­
tor.

Other available products


¾ KVR-R-HP: High pressure constant volume dampers with a pressure range between 150 and 600Pa

B02 KVR-R 1/3 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

B02 260
Adjustable constant air volume
dampers
KVR-R
Prices
Type Diameter Airflow range Factory setpoint Article number / Price
[mm] [m³/h] [m³/h] KVR-R SD TX (**) SDL TX (**)
B020102 x D011105000010 D011105001010
x= Price Price Price
KVR-R Ø80 15m³/h 80 15 - 50m³/h 15 080015 11.68 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø80 25m³/h 80 15 - 50m³/h 25 080025 11.68 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø80 30m³/h 80 15 - 50m³/h 30 080030 11.68 ˜˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø80 45m³/h 80 15 - 50m³/h 45 080045 11.68 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø80 50m³/h 80 15 - 50m³/h 50 080050 11.68 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø100 15m³/h 100 15 - 50m³/h 15 100015 14.16 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø100 25m³/h 100 15 - 50m³/h 25 100025 14.16 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø100 30m³/h 100 15 - 50m³/h 30 100030 14.16 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø100 45m³/h 100 15 - 50m³/h 45 100045 14.16 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø100 50m³/h 100 15 - 50m³/h 50 100050 14.16 ˜˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø100 60m³/h 100 51 - 100m³/h 60 100060 14.16 ˜˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø100 75m³/h 100 51 - 100m³/h 75 100075 14.16 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø100 90m³/h 100 51 - 100m³/h 90 100090 14.16 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø100 100m³/h 100 51 - 100m³/h 100 100100 14.16 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø125 15m³/h 125 15 - 50m³/h 15 125015 16.04 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø125 25m³/h 125 15 - 50m³/h 25 125025 16.04 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø125 30m³/h 125 15 - 50m³/h 30 125030 16.04 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø125 45m³/h 125 15 - 50m³/h 45 125045 16.04 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø125 50m³/h 125 15 - 50m³/h 50 125050 16.04 ˜˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø125 60m³/h 125 51 - 100m³/h 60 125060 16.04 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø125 75m³/h 125 51 - 100m³/h 75 125075 16.04 ˜˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø125 90m³/h 125 51 - 100m³/h 90 125090 16.04 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø125 100m³/h 125 51 - 100m³/h 100 125100 16.04 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø125 120m³/h 125 101 - 180m³/h 120 125120 16.04 ˜˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø125 150m³/h 125 101 - 180m³/h 150 125150 16.04 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø125 180m³/h 125 101 - 180m³/h 180 125180 16.04 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø150 50m³/h 150 15 - 50m³/h 50 150050 23.80 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø150 100m³/h 150 51 - 100m³/h 100 150100 23.80 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø150 120m³/h 150 101 - 180m³/h 120 150120 23.80 ˜˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø150 150m³/h 150 101 - 180m³/h 150 150150 23.80 9.70 ˜˜ 2.32 ˜˜ B
KVR-R Ø150 180m³/h 150 101 - 180m³/h 180 150180 23.80 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø150 210m³/h 150 181 - 300m³/h 210 150210 23.80 ˜˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø150 240m³/h 150 181 - 300m³/h 240 150240 23.80 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø150 250m³/h 150 181 - 300m³/h 250 150250 23.80 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø150 270m³/h 150 181 - 300m³/h 270 150270 23.80 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø150 300m³/h 150 181 - 300m³/h 300 150300 23.80 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø160 50m³/h 160 15 - 50m³/h 50 160050 23.80 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø160 100m³/h 160 51 - 100m³/h 100 160100 23.80 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø160 120m³/h 160 101 - 180m³/h 120 160120 23.80 ˜˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø160 150m³/h 160 101 - 180m³/h 150 160150 23.80 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø160 180m³/h 160 101 - 180m³/h 180 160180 23.80 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø160 210m³/h 160 181 - 300m³/h 210 160210 23.80 ˜˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø160 240m³/h 160 181 - 300m³/h 240 160240 23.80 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø160 250m³/h 160 181 - 300m³/h 250 160250 23.80 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø160 270m³/h 160 181 - 300m³/h 270 160270 23.80 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø160 300m³/h 160 181 - 300m³/h 300 160300 23.80 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø200 180m³/h 200 100 - 180m³/h 180 200180 35.78 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø200 210m³/h 200 181 - 300m³/h 210 200210 35.78 ˜˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø200 240m³/h 200 181 - 300m³/h 240 200240 35.78 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø200 250m³/h 200 181 - 300m³/h 250 200250 35.78 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø200 270m³/h 200 181 - 300m³/h 270 200270 35.78 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø200 300m³/h 200 181 - 300m³/h 300 200300 35.78 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø200 350m³/h 200 301 - 500m³/h 350 200350 35.78 ˜˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø200 400m³/h 200 301 - 500m³/h 400 200400 35.78 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø200 450m³/h 200 301 - 500m³/h 450 200450 35.78 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø200 500m³/h 200 301 - 500m³/h 500 200500 35.78 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø250 300m³/h 250 180 - 300m³/h 300 250300 46.22 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø250 350m³/h 250 301 - 500m³/h 350 250350 46.22 ˜˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø250 400m³/h 250 301 - 500m³/h 400 250400 46.22 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø250 450m³/h 250 301 - 500m³/h 450 250450 46.22 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø250 500m³/h 250 301 - 500m³/h 500 250500 46.22 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø250 550m³/h 250 501 - 700m³/h 550 250550 52.90 ˜˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø250 600m³/h 250 501 - 700m³/h 600 250600 52.90 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø250 650m³/h 250 501 - 700m³/h 650 250650 52.90 ˜ 9.70 ˜˜ 2.32 ˜˜
KVR-R Ø250 700m³/h 250 501 - 700m³/h 700 250700 52.90 ˜ 9.70 ˜˜ 2.32 ˜˜
˜ R Stock product Zaventem, except sales
˜ R Stock product local warehouses, except sales
(**) SD TX: See page 264; SDL TX: See page 264

B02 KVR-R 2/3 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

B02 261
Adjustable constant air volume
dampers
KVR-R
Dimensions
KVR-R D1[mm] D2[mm] L[mm]
Ø 80 76 76 55
Ø 100 96 93 70
Ø 125 120 117 86
Ø 150 146 148 91
Ø 160 146 148 91
Ø 200 190 195 91
Ø 250 245 236 127

Ø 80-Ø125

Ø 150-Ø 250

Construction
¾ 1. Collar with sealing
¾ 2. Intermediate piece according to the air flow rate
¾ 3. Casing
¾ 4. Regulating element
¾ 5. Air flow rate regulating module
¾ 6. Blocking screw for regulating module

Adjustment

B02 KVR-R 3/3 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

262
Adjustable constant air volume B02
dampers
KVR-R HP
Constant volume control dampers for high pressures made of fire retardant plastics.
The range covers an air flow range between 50 up to 1200 m³/h within a pressure range from 150 up
to 600 Pa.
Application
¾ To obtain constant air volumes in ventilation and air conditioning systems within a pressure range
between 150 and 600Pa
¾ For air supply or exhaust duct systems
¾ Maximum working temperature 60°C

Material
¾ Fire retardant plastics classified M1
¾ Body in steel for diameter 160 to 250

Composition
¾ Valve and piston made out of fire retardant plastics M1
¾ Body in fire retardant plastics M1 or steel for diameter 160 to 250
¾ Stainless steel calibrated spring
¾ Rubber air-tight sealing

Mounting
¾ To be inserted inside round ducts
¾ For horizontal of vertical mounting
¾ When horizontally mounted the marking "BAS" must be horizontal
¾ To be placed according the marked airflow direction
¾ To be placed in air supply at a minimum distance of 3x the duct diameter from air supply grilles
and at the same distance close to areas with high turbulance like duct connections, bends,...
¾ To be placed in air exhaust at a minimum distance of 1x the duct diameter from air exhaust grilles
and at the same distance close to areas with high turbulance like duct connections, bends,...
¾ The flow regulator must be accessible to allow maintenance.

Accessories
¾ Screwdriver or T10 Torx bit to unscrew the screw for adjusting the air flow from the regulator

B02 KVR-R HP 1/3 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

B02 263
Adjustable constant air volume
dampers
KVR-R HP
Prices
Type Diameter Airflow range Factory setpoint Article number / Price
[mm] [m³/h] [m³/h] KVR-R HP SD TX (**) SDL TX (**)
B020121 x D011105000010 D011105001010
x= Price Price Price
KVR-HP-R Ø80 25m³/h 80 25 - 90m³/h 25 080025 13.08 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø80 50m³/h 80 25 - 90m³/h 50 080050 13.08 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø80 75m³/h 80 25 - 90m³/h 75 080075 13.08 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø100 25m³/h 100 25 - 90m³/h 25 100025 15.88 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø100 50m³/h 100 25 - 90m³/h 50 100050 15.88 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø100 75m³/h 100 25 - 90m³/h 75 100075 15.88 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø100 100m³/h 100 91 - 170m³/h 100 100100 15.88 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø100 125m³/h 100 91 - 170m³/h 125 100125 15.88 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø100 150m³/h 100 91 - 170m³/h 150 100150 15.88 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø125 25m³/h 125 25 - 90m³/h 25 125025 17.74 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø125 50m³/h 125 25 - 90m³/h 50 125050 17.74 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø125 75m³/h 125 25 - 90m³/h 75 125075 17.74 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø125 100m³/h 125 91 - 170m³/h 100 125100 17.74 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø125 125m³/h 125 91 - 170m³/h 125 125125 17.74 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø125 150m³/h 125 91 - 170m³/h 150 125150 17.74 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø125 200m³/h 125 180 - 300m³/h 200 125200 17.74 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø125 250m³/h 125 180 - 300m³/h 250 125250 17.74 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø125 300m³/h 125 180 - 300m³/h 300 125300 17.74 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø150 75m³/h 150 25 - 90m³/h 75 150075 26.60 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø150 150m³/h 150 91 - 170m³/h 150 150150 26.60 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø150 200m³/h 150 180 - 300m³/h 200 150200 26.60 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø150 250m³/h 150 180 - 300m³/h 250 150250 26.60 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø150 300m³/h 150 180 - 300m³/h 300 150300 26.60 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø150 350m³/h 150 301 - 500m³/h 350 150350 26.60 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø150 400m³/h 150 301 - 500m³/h 400 150400 26.60 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø150 450m³/h 150 301 - 500m³/h 450 150450 26.60 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø150 500m³/h 150 301 - 500m³/h 500 150500 26.60 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø160 75m³/h 160 25 - 90m³/h 75 160075 26.60 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø160 150m³/h 160 91 - 170m³/h 150 160150 26.60 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø160 200m³/h 160 180 - 300m³/h 200 160200 26.60 9.70 ˜˜ 2.32 ˜˜ B
KVR-HP-R Ø160 250m³/h 160 180 - 300m³/h 250 160250 26.60 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø160 300m³/h 160 180 - 300m³/h 300 160300 26.60 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø160 350m³/h 160 301 - 500m³/h 350 160350 26.60 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø160 400m³/h 160 301 - 500m³/h 400 160400 26.60 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø160 450m³/h 160 301 - 500m³/h 450 160450 26.60 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø160 500m³/h 160 301 - 500m³/h 500 160500 26.60 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø200 150m³/h 200 90 - 170m³/h 150 200150 40.00 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø200 300m³/h 200 180 - 300m³/h 300 200300 40.00 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø200 350m³/h 200 301 - 500m³/h 350 200350 40.00 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø200 400m³/h 200 301 - 500m³/h 400 200400 40.00 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø200 450m³/h 200 301 - 500m³/h 450 200450 40.00 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø200 500m³/h 200 301 - 500m³/h 500 200500 40.00 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø200 600m³/h 200 501 - 850m³/h 600 200600 40.00 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø200 700m³/h 200 501 - 850m³/h 700 200700 40.00 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø200 800m³/h 200 501 - 850m³/h 800 200800 40.00 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø250 300m³/h 250 180 - 300m³/h 300 250300 51.66 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø250 500m³/h 250 301 - 500m³/h 500 250500 51.66 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø250 600m³/h 250 501 - 850m³/h 600 250600 51.66 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø250 700m³/h 250 501 - 850m³/h 700 250700 51.66 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø250 800m³/h 250 501 - 850m³/h 800 250800 51.66 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø250 900m³/h 250 851 - 1200m³/h 900 250900 59.44 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø250 1000m³/h 250 851 - 1200m³/h 1000 250A00 59.44 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø250 1100m³/h 250 851 - 1200m³/h 1100 250B00 59.44 9.70 ˜˜ 2.32 ˜˜
KVR-HP-R Ø250 1200m³/h 250 851 - 1200m³/h 1200 250C00 59.44 9.70 ˜˜ 2.32 ˜˜
˜ R Stock product Zaventem, except sales
˜ R Stock product local warehouses, except sales
(**) SD TX: See page 264; SDL TX: See page 264

Dimensions
RD D1[mm] D2[mm] L[mm]
Ø 80 76 76 55
Ø 100
Ø 125
96
120
93
117
70
86
D1 D2
Ø 150 146 148 91
Ø 160 146 148 91
Ø 200 190 195 91
Ø 250 245 236 127 L

B02 KVR-R HP 2/3 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

B02 264
Adjustable constant air volume
dampers
KVR-R HP
Adjustment

Ø 80 et 100 mm Ø 125 à 250 mm

SD TX
Screwdriver TORX
Screwdriver for airflow adjustment of KVR-R and KVR-R HP valves
Application
¾ For scewing TORX screws size TX10
¾ Airflow adjustment of KVR-R and KVR-R HP valves

Prices
Type TORX Size Article number Price
SD TX
SD TX10 TX10 D011105000010 9.70 ˜˜
˜
˜
R Stock product Zaventem, except sales
R Stock product local warehouses, except sales
B

SDL TX
L-screwdriver TORX
Economic L-screwdriver for airflow adjustment of KVR-R and KVR-R HP valves
Application
¾ For scewing TORX screws size TX10
¾ Airflow adjustment of KVR-R and KVR-R HP valves

Prices
Type TORX Size Article number Price
SDL TX
SDL TX10 TX10 D011105001010 2.32 ˜˜
˜ R Stock product Zaventem, except sales
˜ R Stock product local warehouses, except sales

B02 KVR-R HP, SD TX, SDL TX 3/3 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

265
Constant air volume control B02
dampers
VRS
Adjustable self-regulating constant air volume control dampers in galvanised steel.
To be used to regulate airstreams at pressures between 50 and 1000 Pa and temperature ranges
between –30°C and 100°C. Air-flow value can easily be changed by use of an allen key SW2
Application
¾ For air volume regulation in ventilation and air-conditioning systems with following air volumes
and duct sizes
¾ VRS 80: to be set between
40 & 125m³/h
¾ VRS100: to be set between
70 & 220m³/h
¾ VRS125: to be set between
100 & 280m³/h
¾ VRS150: to be set between
170 & 450m³/h
¾ VRS160: to be set between
180 & 500m³/h
¾ VRS200: to be set between
250 & 900m³/h
¾ VRS250: to be set between
500 & 1500m³/h
¾ VRS315: to be set between
800 & 3000m³/h
¾ VRS355: to be set between
900 & 3200m³/h
¾ VRS400: to be set between
1000 & 4500m³/h
Material
¾ Galvanized steel housing
¾ Aluminium regulation blade with piston and spring

Composition
¾ Round housing made out of laser welded galvanised steel in standard duct sizes
¾ Rubber duct sealing
¾ Balanced self-regulating aluminium blade with PTFE bearing and piston to prevent oscillations

Mounting
¾ To be inserted at both sides into a round duct and to be equipped with a silencer if necessary
¾ horizontal or vertical mounting

Accessories B
¾ Stainless steel models or insulation shells available upon request

Other available products


¾ Version ATEX available upon request

Prices
Type Diameter Airflow range Factory setpoint Article number Price
[mm] [m³/h] [m³/h] VRS
VRS 080 80 40 - 125 90 B020201080000 81.26 ˜
VRS 100 100 70 - 220 130 B020201100000 78.08 ˜˜
VRS 125 125 100 - 280 200 B020201125000 84.46 ˜˜
VRS 150 150 170 - 450 300 B020201150000 87.64 ˜
VRS 160 160 180 - 500 350 B020201160000 87.64 ˜˜
VRS 200 200 250 - 900 500 B020201200000 94.02 ˜˜
VRS 250 250 500 - 1600 800 B020201250000 104.00 ˜˜
VRS 315 315 800 - 2800 1300 B020201315000 150.00 ˜˜
VRS 355 355 900 - 3200 1500 B020201355000 194.00 ˜
VRS 400 400 1000 - 4000 2000 B020201400000 214.00 ˜
˜ R Stock product Zaventem, except sales
˜ R Stock product local warehouses, except sales

Dimensions
VRS ØD [mm] L1 [mm] L2 [mm] H [mm] SW2
max
80 79 120 40 70
H

min
100 99 170 40 70
125 124 170 40 70
150 149 240 40 70
160 159 240 40 70
ØD

200 199 240 40 70


250 249 240 40 70
315 314 220 60 110
355 354 295 60 110
400 398 295 60 110 L2 L1 L2

B02 VRS 1/1 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

266
Rectangular volume control B02
dampers
VRRK
Adjustable self-regulating constant air volume control damper in galvanised steel. To be used to
regulate airstreams at pressures between 50 and 1000 Pa and temperature ranges between –30°C
and 100°C. Big sizes will consist of a double valve. Possible set ranges are obtained by installed
calibrated springs. Therefore the desired air volume should always be selected and mentioned when
ordering, within a certain set range of the possible springs.
Application
¾ For air volume regulation in rectangular ventilation and air-conditioning systems

Material
¾ Galvanized steel housing
¾ Aluminium regulation blade with piston and spring

Composition
¾ Rectangular housing made out of laser welded galvanised steel in standard duct sizes with flange
30 mm
¾ Balanced self-regulating aluminium blade with PTFE bearing and piston to prevent oscillations

Mounting
¾ To be joined at both sides with the rectangular ductwork
¾ Horizontal or vertical mounting

Accessories
¾ Stainless steel models and insulation shells available upon request

Other available products


¾ In between dimensions available upon request
¾ Version ATEX available upon request
¾ Stainless steel version available upon request

Prices
Article number - = B020301 x y
L Hole [mm]
150 200 250 300 350 400 450 500 550 600
x=
150 200 250 300 350 400 450 500 550 600
H Hole [mm] y= Price
100 100 286.00 298.00 310.00
150 150 303.00 303.00 303.00 303.00 325.00 325.00
200 200 303.00 303.00 303.00 325.00 325.00 B
250 250 331.00 331.00 331.00 345.00 345.00 345.00
300 300 350.00 350.00 350.00 363.00 363.00 366.00 366.00
400 400 577.00 611.00 616.00
500 500 622.00 636.00
600 600 652.00

Dimensions
H2

H2

H2

H [mm] D [mm] H2 [mm]


H <= 200 D=220 70
250 <= H <= 400 D=385 60
H

H=500 D=425 60
H=600 D=470 60
H
30

L
30
D
30

L
30

B02 VRRK 1/2 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

B02 267
Rectangular volume control
dampers
VRRK
Air performance data
Type Qv [m³/h]
VRRK 150 x 150 200-250 / 250-350 / 300-500 / 400-700
VRRK 200 x 100 200-350 / 300-600
VRRK 200 x 150 250-350
VRRK 200 x 200 400-600 / 400-650 / 600-1000
VRRK 250 x 150 300-600
VRRK 250 x 200 400-600 / 600-800 / 800-1400
VRRK 250 x 250 640-1000 / 800-1300 / 1300-2300
VRRK 300 x 100 200-400 / 300-600 / 400-800
VRRK 300 x 150 400-800
VRRK 300 x 200 500-1100 / 1000-1700 / 1500-2000
VRRK 300 x 250 800-1500 / 1300-2700
VRRK 300 x 300 700-1200 / 1100-2100 / 2000-3000
VRRK 350 x 150 500-1100
VRRK 350 x 200 700-1200 / 1100-1900 / 1000-2500
VRRK 350 x 250 800-1500 / 1300-2300 / 1800-3200
VRRK 350 x 300 1500-2200 / 2000-3000
VRRK 400 x 100 300-600 / 500-1100
VRRK 400 x 150 600-900
VRRK 400 x 200 600-900 / 800-1500 / 1400-2200 / 2100-2800
VRRK 400 x 250 1000-1600 / 1500-2700 / 2000-3500
VRRK 400 x 300 1100-1600 / 1300-2500 / 1500-3000 / 2500-4300
VRRK 400 x 400 1200-3600 / 3000-5000 / 4000-5600
VRRK 450 X 200 900-1700 / 1500-2500
VRRK 450 x 250 1000-2000 / 1300-2500 / 2200-4000
VRRK 450 x 300 1000-1700 / 1500-2500 / 2000-4200 / 3500-4500
VRRK 500 x 200 1000-2250 / 2000-3500
VRRK 500 x 250 1300-2500 / 2000-3600 / 2500-4300
VRRK 500 x 300 1000-1200 / 1000-2000 / 1500-3000 / 2500-4000 / 4000-5000 / 3600-5500
VRRK 500 x 400 2000-4500 / 4000-7000
VRRK 500 x 500 2600-5600 / 4000-7200 / 5000-8600
VRRK 550 x 250 1300-2500 / 2000-4000
VRRK 550 x 300 2000-4000
VRRK 600 x 200 1000-2500 / 1500-3500 / 2500-4500 B
VRRK 600 x 250 1500-3500 / 2000-5000
VRRK 600 x 300 1500-3000 / 2500-4500 / 4500-6000 / 4500-6500
VRRK 600 x 400 2000-5000 / 3000-7000 / 5000-9000
VRRK 600 x 500 3000-7000 / 4000-10000
VRRK 600 x 600 3000-6000 / 5000-9000 / 9000-13000

B02 VRRK 2/2 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

268
B03
Iris dampers
IRIS
Galvanized steel IRIS air volume control damper of the diaphragm type with pressure measuring points
Available in range from Ø80 up to Ø800 mm
Application
¾ For air volume control and measurement in ventilation and air conditioning systems.
¾ The diaphragm valve ensures a perfect accordance between the diameter indication on the handle
and the opening of the valve
Material
¾ Galvanized steel

Composition
¾ Body and valve made of galvanized sheet steel
¾ Plastic regulating nut with plastic key
¾ Measuring point on either side of the valve for connection of manometer
¾ Sticker with selection graph, mentioning the air volume at the different opening positions of the
valve and the according pressure level
¾ Flexible joints for air tightness when placed inside the duct

Order example
IRIS 125
¾ IRIS: Type of damper
¾ 125: Connection diameter

Prices
Type Diameter Article number Price Type Diameter Article number Price
[mm] IRIS [mm] IRIS
IRIS 80 80 B030101080000 34.78 ˜ IRIS 250 250 B030101250000 55.78 ˜˜
IRIS 100 100 B030101100000 20.14 ˜˜ IRIS 315 315 B030101315000 70.60 ˜˜
IRIS 125 125 B030101125000 21.58 ˜˜ IRIS 400 400 B030101400000 167.00 ˜
IRIS 150 150 B030101150000 29.34 IRIS 500 500 B030101500000 232.00 ˜
IRIS 160 160 B030101160000 33.74 ˜˜ IRIS 630 630 B030101630000 350.00 ˜
IRIS 200 200 B030101200000 37.96 ˜˜ IRIS 800 800 B030101800000 465.00
˜ R Stock product Zaventem, except sales
˜ R Stock product local warehouses, except sales

Dimensions
IRIS ød [mm] øD [mm] A [mm] L [mm]
A A
80
100
79
99
125
165
35
30
120
110
B
125 124 188 30 110
150 149 230 30 110
160 159 230 30 110
Ød

200 199 285 30 110


250 249 335 40 132
315 314 410 40 132
400 398 525 50 155
500 498 655 50 170
630 628 815 50 170 ØD L
800 798 1015 100 270

B03 IRIS 1/1 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

269
B04

Circular control valves


SAVD P.270 KRK-A P.273 KRK-A-TP P.274 BYPASS P.275 ESAR P.276

˜˜ ˜˜

¾ Regulating damper ¾ Valve with actuator ¾ Valve with actuator ¾ Bypass damper ¾ Smoke valves
¾ Sound attenuating ¾ Continuous operation ¾ Continuous operation ¾ Circular

˜ R Stock product Zaventem, except sales


˜ R Stock product local warehouses, except sales

www.sigairhandling.be
B - Valves & volume control dampers

270
Sound attenuation volume B04
dampers
SAVD
Sound attenuating volume control dampers in polyurethane foam
Application
¾ For air regulation and acoustic attenuation in ventilation and airconditioning systems
¾ To be inserted easily into round ducts with low sound generation even at large pressure drops
¾ Pressure and airflow are easily adjustable by varying the number of open holes of the damper
¾ Multiple dampers can be used to obtain higher acoustic attenuation

Material
¾ Damper mainly made out of flexible polyurethane foam with very good damping abilities and
flameresistance tested according FMVSS-302, the fabric flammability standard, wich is also the
standard used in e.g. the automotive industry. Fire resistance class B (Equivalent to M1)
¾ Cut-out holes with parts that can easily be taken out to adjust air volumes
¾ Anti-bacterial anti-fungus foam mousse
¾ Rot-free

Mounting
¾ To be inserted in circular ducts of Ø80, Ø100, Ø125, Ø160, Ø200, Ø250 and Ø315
¾ Dampers for ducts in Ø315 available upon request
¾ To be mounted at at least 50-350 mm distance A between the duct opening and first SAVD damper
when used in air supply
¾ To be mounted at at least 0-50 mm distance A between the duct opening and the first SAVD damper
when used for exhaust of air
¾ To be mounted at a minimum distance B in between 2 dampers at at least 250 mm in air supply
and 150 mm in air exhaust when multiple dampers are mounted
Prices
Type Diameter Article number Price Type Diameter Article number Price
[mm] SAVD [mm] SAVD
SAVD 80 80 B040106080000 7.20 ˜ SAVD 200 200 B040106200000 20.28 ˜˜
SAVD 100 100 B040106100000 7.60 ˜˜ SAVD 250 250 B040106250000 48.20 ˜
SAVD 125 125 B040106125000 10.08 ˜˜ SAVD 315 315 B040106315000 68.76 ˜
SAVD 160 160 B040106160000 13.02 ˜˜
˜ R Stock product Zaventem, except sales
˜ R Stock product local warehouses, except sales

B04 SAVD 1/3 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

B04 271
Sound attenuation volume
dampers
SAVD
Technical characteristics

B04 SAVD 2/3 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

B04 272
Sound attenuation volume
dampers
SAVD
List of symbols
¾ Dpt = Pressure loss over the damper in Pa
¾ Q = Air Volume in m³/h
¾ LWA= Sound power in dBA
¾ 1-2- ... -10 = Quantity of opened holes in the damper

Acoustic attenuation
Open Holes 63 Hz 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz
1 5.0 6.0 5.0 5.0 12 13 18 22
SAVD 80 2 2.0 2.0 2.0 3.0 8.0 6.0 14 19
3 1.0 1.5 1.5 2.0 5.0 5.0 10 16
1 6.5 7.0 4.0 9.5 13 16 18 22
SAVD 100 3 3.0 3.5 2.5 5.5 8.5 8.5 15 19
5 1.5 2.5 1.5 3.5 6.0 6.5 12 17
2 5.0 6.0 5.0 5.0 12 13 19 21
SAVD 125 5 2.0 2.0 2.5 3.0 8.5 8.0 14 19
8 1.0 1.5 1.5 2.5 6.0 5.0 11 18
1 6.5 7.0 4.0 9.5 13 16 18 22
SAVD 160 3 3.0 3.5 2.5 5.5 8.5 8.5 15 20
5 1.5 2.5 1.5 3.5 6.0 6.0 12 17
2 4.0 6.5 2.5 5.5 13 14 18 16
SAVD 200 5 2.0 3.0 1.5 2.5 9.5 8.5 14 15
8 2.0 2.0 1.0 1.5 7.0 7.0 13 14
0 5.0 4.0 3.0 7.0 13 18 18 17
2 4.0 4.0 2.0 6.0 11 16 18 15
SAVD 250
6 3.0 2.0 2.0 5.0 9.0 13 15 15
10 2.0 2.0 1.0 3.0 7.0 11 14 13

Sound power level


63 Hz 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 8 kHz
SAVD 80 6 4 3 0 -9 -10 -17 -24
SAVD 100 6 4 3 0 -9 -10 -17 -24
SAVD 125 4 2 1 0 -8 -10 -18 -24
SAVD 160 5 4 3 0 -9 -10 -18 -22
SAVD 200 4 2 5 -4 -10 -15 -20 -25
SAVD 250 5 4 3 0 -9 -10 -18 -22 B
SAVD 315 4 2 5 -4 -10 -15 -20 -25

Dimensions ØD2 S B A
D1 [mm] D2 [mm] S [mm]
SAVD 80 80 82 50
SAVD 100 100 102 50 ØD 1
SAVD 125 125 127 50
SAVD 160 160 162 50
SAVD 200 200 202 50
SAVD 250 250 252 75
SAVD 315 315 318 75

B04 SAVD 3/3 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

273
Round control dampers with B04
actuator
KRK-A
Round control valves with actuator, opened when under current with returnspring
Application
¾ For air regulation in ventilation and airconditioning systems, cookerhoods, ...
¾ Air volume loss in closed position of less than 3 m³/h for Ø125 and 8 m³/h for Ø150, Ø160 and
Ø200 (at 100 Pa)
¾ No Limited time under current
¾ Max. Temperature 60°C
¾ Maximum pressure 200 Pa
¾ Response time 8 seconds
¾ Consumption 2W

Material
¾ Valve and housing made of fire retardant plastics
¾ Connections at both sides of the valve made of galvanized steel
¾ Actuator 230V with spring-return

Composition
¾ Round body with valve
¾ Two wired actuator with spring return
¾ Duct connection flanges

Mounting
¾ To be mounted in between two round ducts
2
¾ Connected to current 230V by 2 wires 0,75 mm

Prices
Type Diameter Article number Price Type Diameter Article number Price
[mm] KRK-A [mm] KRK-A
KRK-A 100 100 B040501100000 102.00 ˜˜ KRK-A 160 160 B040501160000 110.00 ˜˜
KRK-A 125 125 B040501125000 105.00 ˜˜ KRK-A 200 200 B040501200000 115.00 ˜˜
KRK-A 150 150 B040501150000 110.00 ˜˜
˜ R Stock product Zaventem, except sales
˜ R Stock product local warehouses, except sales

Dimensions
KRK-A øD [mm] h [mm] L [mm]

h
100 99 100 200
125 124 100 200
B
ØD
150 149 100 200
160 159 100 200
200 199 100 200 L

B04 KRK-A 1/1 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

274
Circular bi-flow dampers with B04
actuator
KRK-A-TP
Round bi-flow control valves with actuator, opened when under current and with spring return
Minimal and maximal air volumes can be adjusted on site
Application
¾ For air regulation in ventilation and airconditioning systems, cookerhoods, ...
¾ No Limited time under current
¾ Max. Temperature 60°C
¾ Maximum pressure 200 Pa
¾ Response time 8 seconds
¾ Consumption 2.5W

Material
¾ Valve, housing and constant volume dampers made of fire retardant plastics
¾ Connections at both sides of the valve made of galvanized steel
¾ Actuator 230V with spring-return (only to be installed on the top side)

Composition
¾ Round body and motorized blade, each equipped with an adjustable constant volume damper in
order to make the bi-flow control possible. The constant volume damper in the blade provides the
minimum air flow rate when the blade is closed. The bigger constant volume damper in the duct
provides the maximum air flow rate in the damper when closed.
¾ KRK-A-TP 125: adjustable from 15 to 50 m³/h (in the blade) and from 50 to 180 m³/h (in the
duct)
¾ KRK-A-TP 150: adjustable from 15 to 100 m³/h (in the blade) and from 100 to 300 m³/h (in
the duct)
¾ KRK-A-TP 160: adjustable from 15 to 100 m³/h (in the blade) and from 100 to 300 m³/h (in
the duct)
¾ KRK-A-TP 200: adjustable from 15 to 100 m³/h (in the blade) and from 100 to 500 m³/h (in
the duct)
¾ Actuator equipped with two supply cables and spring return
¾ Connection flanges for ducts

Mounting
¾ To be mounted in between two round ducts
¾ Airstream direction mentioned on the valve to be taken into acount!
2
¾ Connected to current 230V by 2 wires 0,75 mm

Prices
Type Diameter Article number Price Type Diameter Article number Price
[mm] KRK-A-TP (*) [mm] KRK-A-TP (*)
KRK-A-TP 125
KRK-A-TP 150
125
150
B040503125000
B040503150000
135.00
150.00
KRK-A-TP 160
KRK-A-TP 200
160
200
B040503160000
B040503200000
150.00
167.00
B
(*) When ordering min. and max. air volume should be mentionned

1. Galvanized duct connections


2. Plastic valve body with valve blade 5
3. Small KVR-R constant volume damper mounted within the valve
blade H
4. Big KVR-R constant volume damper mounted withing the duct
connection 1
5. Actuator 230V with spring return
6. Airflow direction
4

2
6
ØD

3
L

Dimensions
KRK-A-TP øD [mm] h [mm] L [mm]
125 124 100 280
150 149 100 280
160 159 100 280
200 199 100 280

B04 KRK-A-TP 1/1 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

275
B04
Motorized bypass
BYPASS
A BYPASS is a distributor with 3 ducts and 2 positions with an electric controller. The action on the
reversing switch allows to switch from one duct to another.
Application
¾ Creates a bypass in ventilation and airconditioning system

Composition
¾ Body in galvanized steel with a thickness of 0,75mm with 3 branches
¾ Mobile valve in sheet plate (1) with foam for sealing
¾ Electric engine (2) and 2 limit switches (3)
¾ Reversing switch (4) + connection cable (included)

Mounting
¾ The bypass comes with cable. Connection 230 V + T
¾ Provide a phase circuit breaker + neutral 1 A for safety
¾ Before all interventions on the bypass, shut down the power on the electrical switch-board
¾ Ducts are connetected to branches, fixation by putty, scotch or clamps
¾ The bypass should remain accessible for maintenance operations
¾ The bypass 200 must be positioned flat (with actuator on top or underneath) for proper operation

Other available products


¾ Manual motorizable bypass type ATH90

Prices
Type Diameter Article number / Price Type Diameter Article number / Price
[mm] BYPASS [mm] BYPASS
B040301 x 000 B040301 x 000
x= Price x= Price
BYPASS 125 125 125 224.00 BYPASS 160 160 160 234.00
BYPASS 150 150 150 234.00 BYPASS 200 200 200 279.00

Dimensions
A (mm) B (mm) C (mm)
BYPASS 125 210 240 240
BYPASS 150 210 240 240
BYPASS 160 210 240 240
BYPASS 200 340 340 340

Wiring diagramm

4
2

3 1

B04 BYPASS 1/1 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

276
Motorized circular smoke B01
dampers
ESAR
Circular smoke control damper ESAR is specially designed to use in single fire compartment
applications as a closing or as an opening damper for smoke extract purposes. ESAR is fulfilling the
european product standard EN12101-8 requirements for single compartment applications and it is
CE marked. The product has been tested according to EN 1366-10 fulfilling firclass E 120 S with
pressure class 1000 Pa and temperature class 600°C. ESAR dampers are suitable both for automatically
by a fire alarm actiated systems (AA) and manually, after the fire has started, by fire fighter acated
systems (MA), 25 min open / close. ESAR smoke control damper is designed so, that opening or closing
can be made even 25 minutes after the fire has started, in 600°C. Factory mounted electrical actuator
is placed inside fireresistant calcium-silicate box.
Application
¾ ESAR has been designed to use in single fire compartment applications as a closing or as an opening
damper for smoke extract purposes.
Material
¾ Galvanized steel duct and circular damper blade
¾ Smoke control damper ESAR is always delivered with factory mounted elctrical actuator 24 V or
230 V placed inside calcium-silicate box.
Composition
¾ Galvanized steel body and damper blade
¾ Standard delivered with connection with airtight lipseal
¾ Smoke control damper ESAR is always delivered with factory mounted elctrical actuator 24 V or
230 V inside calcium-silicate box
¾ Smoke control damper has two safety positions open or closed
¾ Smoke control damper is activated to transfer to safety position automatically by smoke detection
or manually by switch used by fire fighters
¾ Electrical actuator has 2 free auxiliary switches for open / close position indication
¾ Fixation plate to be mounted against wall surface

Mounting
¾ Installation instructions (see download area) has to be followed to be able to fulfill fire classification.
¾ The duct outlet must be placed so that the smoke extraction damper is protected from water
coming from outside as well as ice and snow that could hinder the opening of the damper
¾ The ductwork section between the smoke extraction damper and duct outlet must be designed
and insulated so that the fire resistance and tightness requirements are met
¾ Also take account of possible condensation
¾ By design phase and installation work it is very important to notice, that all cable system with
connection boxes has to be done by fire resistant products. Electrical actuator changes the damper
position from open or close with transfer time not more than 60 s. If the electricity is cut off, damper
blade will remain in its position
¾ Flow direction has no affect to the function of the damper
B
Accessories
¾ Connection piece MDV tot mount the damper on another duct accessory
¾ Protection lid with mesh can be supplied with the damper

Certification
¾ Fire tested and CE marked MPA No. 0761-CPD-0278 according the harmonised product standard
EN 12101-8
¾ The smoke extraction damper fulfill the requirements of leakage class 3 according to EN 1751.
¾ The damper casing fulfills the requirments of leakage class C according to EN 1751.
¾ Pressure drop across a closed damper may amount to 2500 Pa
¾ Fire class according to EN 13501-4: E600 120 (ve i o)S 1000C300 MAsingle
¾ Fullfills the requirements for MA clas for opening / closing (25 min, 600 °C)
¾ Suitable both for AA and MA smoke control systems

Other available products


¾ ESAS rectangular smoke dampers with rectangular blades

Prices
Connection diameter Actuator Voltage Article number Price
[mm] [V] ESAR
100 24V E061001000100 805.00
125 24V E061001000125 805.00
160 24V E061001000160 789.00
200 24V E061001000200 798.00
250 24V E061001000250 812.00
315 24V E061001000315 837.00
400 24V E061001000400 883.00
500 24V E061001000500 919.00
630 24V E061001000630 986.00
100 230V E061002000100 961.00
125 230V E061002000125 961.00
160 230V E061002000160 945.00
200 230V E061002000200 954.00
250 230V E061002000250 968.00
315 230V E061002000315 991.00
400 230V E061002000400 1,039.00
500 230V E061002000500 1,073.00
630 230V E061002000630 1,142.00

B01 ESAR 1/3 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

B01 277
Motorized circular smoke
dampers
ESAR
E
318 C
Li
ØD

Max 175

515

Dimensions
ESAR ØD [mm] c [mm] E [mm] Li [mm] [kg]
100 * 160 159 220 35 10.70
125 * 160 159 220 35 10.70
160 160 159 220 35 10.30
200 200 203 260 35 10.80
250 250 237 310 40 11.20
315 315 281 380 40 13.30
400 400 390 470 60 14.70
500 500 480 570 60 17.20
630 630 600 740 60 21.60
* With extension

Electrical wiring diagram


B
L1-L2 open (90°)
L1-L3 closed (0°)

N
T L1
~ AC 230 V
AC 24 V
– + DC 24 V

Closed (<3°) Open (>87°)


Contact between Contact between
S1-S2 S4-S6

1 2 3 S1 S2 S3 S4 S5 S6

<3° <87°

Actuator electrical data


U [V] Max Power [W] Power for wire size
24C AC/DC 0,5W / 12W 18VA
230V AC 0,5W / 8W 15VA

Remarks
¾ Wiring of the actuator has to be done inside the fire resitant calcium-silicate box, since the cable delivered with the actuator is non fire resistant.
The wiring of ESAR smoke control damper must always be done using fire resistant cables and switch boxes in order to guarantee the damper’s
operation in case of fire

B01 ESAR 2/3 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

B01 278
Motorized circular smoke
dampers
ESAR
Pressure drop

0
10

12

16

20

25

31

40

0
100

50
50

0
63
20
∆ pt , Pa

10

2
Lp10A , dB(A)
35 40
1
30 50 100 200 500 1000 2000 5000 10000
qv, l/s
Correction factors
Correction of sound power per octave bands Koct
Frequency band 125 250 500 1000 2000 4000 8000
Correction Koct 16 10 5 0 -7 -13 -18
Tolerance +/- 6 3 3 3 3 3 3
Lwoct = Lp10A + Koct

Symbols and specifications


¾ qv = Airflow l/s
¾ LWokt = Sound power level in the duct in dB
¾ Lp10A = Sound pressure level with 4dB room attenuation (10m²sab)
B
¾ Kokt = Correction factor in dB
¾ Δps = Static pressure drop in Pa

B01 ESAR 3/3 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

279
B05

Variable Volume valves (VAV)


VAV-CS P.280 VAV-B P.281 VAV-RS P.283
(NEW) (NEW) (NEW)

NEW NEW NEW

¾ Circular ¾ Circular/rectangular ¾ Rectangular


¾ Gruner controller ¾ With sound attenuating ¾ Gruner controller
housing
¾ Gruner controller

˜ R Stock product Zaventem, except sales

www.sigairhandling.be
B - Valves & volume control dampers

280
B05
VAV dampers with actuator
VAV-CS (NEW)
VAV-CS air flow regulator can be used both for variable and constant flow and, if appropriate, for forced
shut-off for both air supply and air exhaust
Application
¾ Regulating of air volumes to change the temperature or air quality in a room
¾ Control and regulate the supply air flow and exhaust air flow
¾ Airflow range can be set between two set values or as constant airflow

Material
¾ Galvanized steel

Composition
¾ Operating range is between 2 to 12 m/s
¾ Integrated flow measurement with seperate measurement nipples for control and manual
measurement
¾ The casing of the damper is equipped with a EPDM rubber blade seal conforms to air tightness
class C
¾ Blade air tightness class 3 in accordance with EN1751 due to EPDM Seal around the blade
¾ Manual measurement of the air flow can be performed without disturbing the control circuit
through a separate pressure outlet on the orifice plate of the flow variator
¾ All duct connections have spigot dimensions and are equipped with sealing rings made of rubber

Controls
¾ Controller type GRUNER227VM-024-05 of 5Nm (size 100 up to 500) and GRUNER227VM-024-10
of 10Nm (size 630) are pressure regulated actuators for pressure independent controls and with
a digital display which enables monitoring the airflow and setting up values without external
equipment
¾ Operating range 0-10V or 2-10V (Standard set on 0-10V)
¾ A simple scewdriver can adjust the settings on site
3
¾ Units of airflow: l/s or m /h
¾ Minimum adjustable air volume set at air velocity at 1m/s and maximum adjustable airvolume set
at air velocity of 12m/s
¾ Running time over the full actuator range : 100s
¾ Power consumption 2.5W, 4.0VA
¾ Supply voltage 24V AC/DC

Options
¾ Insulated version VAV-CS-I available upon request
¾ Other versions and brands of actuators available upon request

Accessories
¾ Sound attenuator, type SAR
B
¾ Water heater, type CWA
¾ Electric heater, type CVA

Prices
Type Q (± 3 m/s) [m³/h] Qmin-Qmax Diameter Article number / Price
[m³/h] [mm] VAV-CS (NEW)
B05131A000 x
x= Price
VAV-CS 100 85 37 - 343 100 100 331.00 ˜
VAV-CS 125 133 54 - 540 125 125 333.00 ˜
VAV-CS 160 217 90 - 900 160 160 334.00 ˜
VAV-CS 200 339 145 - 1459 200 200 336.00 ˜
VAV-CS 250 530 217 - 2215 250 250 341.00 ˜
VAV-CS 315 842 380 - 3680 315 315 348.00
VAV-CS 355 1069 482 - 4275 355 355 355.00
VAV-CS 400 1357 615 - 6047 400 400 355.00
VAV-CS 500 2121 973 - 9484 500 500 371.00
VAV-CS 630 3367 1435 - 12482 630 630 418.00
˜ R Stock product Zaventem, except sales

Dimensions
ØD [mm] L [mm] L
VAV-CS 100 98 400
VAV-CS 125 123 400 70
VAV-CS 160 158 400
VAV-CS 200 198 400
VAV-CS 250 248 500
VAV-CS 315 313 600 ØD
VAV-CS 355 353 600
VAV-CS 400 398 600
VAV-CS 500 498 750
VAV-CS 630 628 800 40

B05 VAV-CS (NEW) 1/1 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

281
B05
VAV boxes with build-in actuator
VAV-B (NEW)
VAV-B air flow regulator can be used both for variable and constant flow and, if appropriate, for forced
shut-off for both air supply, type VAV-B-S, and air exhaust, type VAV-B-E.
Application
¾ Regulating of air volumes to change the temperature or air quality in a room
¾ Control and regulate the supply air flow and exhaust air flow
¾ Airflow range can be set between two set values or as constant airflow

Material
¾ Galvanized steel

Composition
¾ Operating range is between 2 and 12 m/s
¾ Integrated flow measurement with seperate measurement nipples for control and manual
measurement
¾ The casing of the damper is equipped with a EPDM rubber blade seal conforms to air tightness
class C
¾ Blade air tightness class 3 in accordance with EN1751 due to EPDM Seal around the blade
¾ Manual measurement of the air flow can be performed without disturbing the control circuit
through a separate pressure outlet on the orifice plate of the flow variator
¾ Acoustic and thermal Insulated box

Controls
¾ Controller GRUNER227VM-024-05 of 5Nm (size 125 up to 400) are pressure regulated actuators
for pressure independent controls and with a digital display which enables monitoring the airflow
and setting up values without external equipment
¾ Operating range 0-10V or 2-10V (Standard set on 0-10V)
¾ A simple scewdriver can adjust the settings on site
3
¾ Units of airflow: l/s or m /h
¾ Minimum adjustable air volume set at air velocity at 2m/s and maximum adjustable airvolume set
at air velocity of 10m/s
¾ Running time over the full actuator range : 100s
¾ Power consumption 2.5W, 4.0VA
¾ Supply voltage 24V AC/DC

Options
¾ Electrical heating battery of water heating battery available upon request
¾ Outlet piece with circular duct connections available upon request

Prices
Type Q (± 3 m/s) [m³/h] Qmin-Qmax
[m³/h]
Execution Article number / Price
VAV-B (NEW)
B
B05331 x
x= Price
VAV-B-S DIA 125 133 54 - 540 Supply A000125 676.00
VAV-B-S DIA 160 217 90 - 900 Supply A000160 710.00
VAV-B-S DIA 200 339 145 - 1459 Supply A000200 849.00
VAV-B-S DIA 250 530 217 - 2215 Supply A000250 993.00
VAV-B-S DIA 315 842 380 - 3680 Supply A000315 1,025.00
VAV-B-S DIA 400 1357 615 - 6047 Supply A000400 1,188.00
VAV-B-E DIA 125 133 54 - 540 Exhaust I000125 676.00
VAV-B-E DIA 160 217 90 - 900 Exhaust I000160 710.00
VAV-B-E DIA 200 339 145 - 1459 Exhaust I000200 849.00
VAV-B-E DIA 250 530 217 - 2215 Exhaust I000250 993.00
VAV-B-E DIA 315 842 380 - 3680 Exhaust I000315 1,025.00
VAV-B-E DIA 400 1357 615 - 6047 Exhaust I000400 1,188.00

H 45 L 70
D

B ØD C

B05 VAV-B (NEW) 1/2 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

B05 282

VAV boxes with build-in actuator


VAV-B (NEW)
Dimensions
VAV-B ØD [mm] B [mm] H[mm] L [mm] C [mm] D [mm]
Ø125 123 300 236 1035 200 150
Ø160 158 410 236 1035 300 150
Ø200 198 560 281 1320 460 200
Ø250 248 700 311 1440 600 200
Ø315 313 900 442 1440 800 250
Ø400 398 1000 525 1820 900 350

B05 VAV-B (NEW) 2/2 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

283
B05
Rectangular VAV dampers
VAV-RS (NEW)
VAV-RS air flow regulator can be used both for variable and constant flow and, if appropriate, for forced
shut-off for both air supply and air exhaust.
Application
¾ Regulating of air volumes to change the temperature or air quality in a room
¾ Control and regulate the supply air flow and exhaust air flow
¾ Airflow range can be set between two set values or as constant airflow

Material
¾ Galvanized steel

Composition
¾ Operating range is between 1 to 12 m/s
¾ Integrated flow measurement with seperate measurement nipples for control and manual
measurement
¾ The damper has stable synthetic bearings and its shaft is mounted in maintenance free synthetic
headings
¾ Blade air tightness class 2 in accordance with EN1751 in closed position
¾ Manual measurement of the air flow can be performed without disturbing the control circuit via a
separate pressure outlet on the orifice plate of the flow variator
Controls
¾ Controller GRUNER227VM-024 is a pressure regulated actuator for pressure independent control
and with a digital display which enables monitoring the airflow and setting up values without
external equipment
¾ Operating range 0-10V or 2-10V (Standard set on 0-10V)
¾ A simple scewdriver can adjust the settings on site
3
¾ Units of airflow: l/s or m /h
¾ Minimum adjustable air volume set at air velocity at 2 m/s and maximum adjustable airvolume set
at air velocity of 12 m/s
¾ Running time over the full actuator range : 100s
¾ Power consumption 2.5W, 4.0VA
¾ Supply voltage 24V AC/DC

Options
¾ Insulated version VAV-RS-I available upon request
¾ Other versions and brands of actuators available upon request

Accessories
¾ Sound attenuator, type BTH-B

Prices B
Article number - = B05231B x y
L [mm]
200 300 400 500 600 700 800 900 1000
x=
200 300 400 500 600 700 800 900 A00
H [mm] y= Price
100 100 404.00 408.00 412.00
200 200 412.00 417.00 421.00 429.00 445.00
300 300 425.00 431.00 439.00 456.00 466.00 482.00 493.00 517.00
400 400 440.00 450.00 467.00 478.00 495.00 506.00 531.00
500 500 460.00 478.00 490.00 516.00 527.00 546.00
600 600 489.00 502.00 529.00 541.00 560.00
700 700 517.00 543.00 557.00 577.00

B05 VAV-RS (NEW) 1/2 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

B05 284

Rectangular VAV dampers


VAV-RS (NEW)
Dimensions
+/-50
VAV-RS L [mm] H [mm] Vnom [m³/h] kg 30
200 x 100 200 100 720 2.8 L 350
200 x 200 200 200 1440 3.7
300 x 100 300 100 1080 3.3 30
300 x 200 300 200 2160 4.5
300 x 300 300 300 3240 5.8
400 x 100 400 100 1440 3.7
H+60 H
400 x 200 400 200 2880 5.4
400 x 300 400 300 4320 7.1
400 x 400 400 400 5760 8.8
500 x 200 500 200 3600 6.2
500 x 300 500 300 5400 8.3
500 x 400 500 400 7200 10.4 L+60
500 x 500 500 500 9000 12.6
600 x 200 600 200 4320 7.1
600 x 300 600 300 6480 9.6
600 x 400 600 400 8640 12.1
600 x 500 600 500 10800 14.7
600 x 600 600 600 12960 17.2
700 x 300 700 300 7560 10.9
700 x 400 700 400 10080 13.8
700 x 500 700 500 12600 16.8
700 x 600 700 600 15120 19.7
700 x 700 700 700 17640 22.7
800 x 300 800 300 8640 12.1
800 x 400 800 400 11520 15.5
800 x 500 800 500 14400 18.9
800 x 600 800 600 17280 22.3
800 x 700 800 700 20160 25.7
900 x 300 900 300 9720 13.4
900 x 400 900 400 12960 17.2
900 x 500 900 500 16200 21
900 x 600 900 600 19440 24.8
900 x 700 900 700 22680 28.6 B
1000 x 300 1000 300 10800 14.7
1000 x 400 1000 400 14400 18.9
1000 x 500 1000 500 18000 23.1
1000 x 600 1000 600 21600 27.3
1000 x 700 1000 700 25200 31.6

B05 VAV-RS (NEW) 2/2 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

285
B06
Healthconnectors
XRM/XRS
CO2 (and humidity) regulated valves available in duct size Ø125, Ø200 and Ø250
Brand
¾ Renson

Application
¾ Master valve XRM: decentralized autonomous regulating valve for (polluted) air extraction in
centralized ventilation systems.
¾ Autonomous precise regulation valve with integrated CO2 probe and dynamic H2O probe for
measurements in the air flow.
¾ Demand-driven precise regulating valve: automatic positioning of the valve blade based on the
measured CO2 and/or relative H2O concentration.
¾ Plug & Play principle: regulating valve to be integrated directly in a spiral duct network.
¾ Adjustable CO2 level and automatic dynamic humidity regulation.
¾ A direct sound attenuation is foreseen for the regulating valve for Ø125 (optionally for Ø200
and Ø250).
¾ The good functioning of the precise regulating valve is only guaranteed if the air supply is
equipped with self-regulating ventilation grilles and if the ventilator pressure is set at max.
200Pa.
¾ Connection of the optional 4 positions switch possible.
¾ Connection of up to 6 slave valves possible.
¾ 0-10V control for connection of driven air supply valves.
¾ Slave valve XRS : The purpose is to guarantee a higher air exhaust flow rate in a single location by
a parallel functioning with the master valves XRM.
¾ The slave valve is a compliant valve without integrated probes.
¾ The positioning of the blade of the slave is controlled by the master valve. The total air exhaust
flow rate in the location is consequently the total of the number of master/slave health
connectors connected in the same location.
¾ Max. 6 slave valves XRS can be connected to 1 master valve XRM.
¾ Optional 4 positions switch (cabled)
¾ Eco-position : ventilation with a minimal energy loss.
¾ Health Care position : ventilation according to the obtained ppm values and air humidity rate.
¾ Manual decrease of the ventilation level.
¾ Manual increase of the ventilation level.
¾ A switch is needed for setting (start-up) of the XRM valves. If several valves are needed to be
set with a single switch, the valves have to be set 1 by 1.

Material
¾ The valve parts are made of ABS
¾ Shutter lid is made of polypropylene
¾ Connection flare is made of galvanized steel
B
Executions
¾ Type XRM = Master valve: CO2 and relative H2O detection + connection possibility of 4-position
switch
¾ Type XRS = Slave valve: actuated by master valve, no detection

Electrical connection
¾ For XRM Ø125: 12V DC Transformer needed with I > 0.5A per XRM. When connecting 1 to 7 slaves
on a master XRM, a transfo of I > 1A should be used. The maximum current from the incomming
current towards the outgoing curren is max 1.25A (peak current can be higher). Therefore max 2
master (3 masters per string) or up to 7 slave valves (7+1 per string) can be connected on the first
masterer. When star connection on the transfo is established, as much masters (slaves) can be
used as the transfo can handle.
¾ For XRM Ø200 and XRM Ø250: 24V DC Transformer needed with I > 0.5A per XRM. When connecting
1 to 4 slaves on a master XRM, a transfo of I > 1A should be used. When connecting 5 to 7 slaves
on a master XRM, a transfo of I > 1.5A should be used.The maximum current from the incomming
current towards the outgoing curren is max 1.25A (peak current can be higher). Therefore max 2
master (3 masters per string) or up to 7 slave valves (7+1 per string) can be connected on the first
masterer. When star connection on the transfo is established, as much masters (slaves) can be
used as the transfo can handle.
Installation
¾ If several Health connectors are connected to a central ventilator, the resistance in the exhaust
duct has to be kept at its minimum.
¾ If several extraction points are connected with the Health connector: provide adjustable extraction
grilles for further precise regulation for each extraction point.
¾ Distance to the exhaust grille: the minimal distance to the first (adjustable) extraction grille has to
be 1 meter.
¾ The Health connector has to be installed within the insulated volume of the non-residential building
(cfr prevention of condensation).

Air flow settings


¾ Maximum exhaust flow rate per valve:
Ø 125: 125m³/h for a maximum speed of 2,8 m/s
Ø 200: 400m³/h for a maximum speed of 3,5 m/s
Ø 250: 600m³/h for a maximum speed of 3,5 m/s
¾ On the basis of the set CO2 ppm level and the obtained measurement, the precise regulating valve
will gradually and autonomously position the valve blade (maximum to the nominal air flow rate).
(If a defined increase of the humidity percentage is perceived for valve Ø125, the valve blade will
return to its nominal position)
¾ The max. desired CO2 limitation in the location can be set for the valve by means of dip switches:
600 ± 50 ppm CO2 (most severe CO2 regulation)
800 ± 50 ppm CO2
900 ± 50 ppm CO2
1000 ± 50 ppm CO2

B06 XRM/XRS 1/2 - 2016/8/30 - BE-EN www.sigairhandling.be


B - Valves & volume control dampers

B06 286

Healthconnectors
XRM/XRS
1100 ± 50 ppm CO2
1200 ± 50 ppm CO2
1400 ± 100 ppm CO2
1600 ± 100 ppm CO2 (less severe CO2 regulation)
¾ Possibility to adjust the (maximum) flow rate by means of the 4 positions switch.
Accessories
¾ 4-position NIKO switch XVK4 for connection on XRM (Master) valves
¾ Silencers type SAR
¾ To be used in combination with energy efficient ECOKAT EC LOBBY+ ventilation boxes

Product drawing
¾ For dimensions see drawings in download area

Prices
Type Connection Ø Qmax Setup Article number Price
[mm] [m3/h] XRM/XRS
XRM 125 125m³/h 125 125 Master B060101125125 511.00
XRM 200 400m³/h 200 400 Master B060101200400 758.00
XRM 250 600m³/h 250 600 Master B060101250600 895.00
XRS 125 125m³/h 125 125 Slave B060102125125 199.00
XRS 200 400m³/h 200 400 Slave B060102200400 332.00
XRS 250 600m³/h 250 600 Slave B060102250600 337.00
Niko 4-ST XVK4 Niko switch B060103000000 88.86

B06 XRM/XRS 2/2 - 2016/8/30 - BE-EN www.sigairhandling.be