Terminations Cold Contractile

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

QT-III Terminations

Cold contractile
Data sheet

Description:
Profits:
Cold shrink QT-III Terminations for indoor or
outdoor dry cable service offer easy and safe Lowest installation cost
installation, as well as reliable performance when Minimal training
terminating power cable. All materials are included in the set
Easy cable preparation (shorter cutting distance)
We have at your disposal terminals for dry cable of
wires or copper tape, special terminals for inverted Compact to facilitate its location in small spaces.
installations.
It does not require additional tools for installation.
High Reliability
Requires no heat, flame, or special tools
Characteristics:
Simple fail-safe installation
Hydrophobic silicone body (does not allow moisture Strain control and seals pre-installed at the factory
accumulation)
Superior resistance to electric shock and erosion Excellent appearance, more professionalism to your
work
Optimal stress control with high dielectric constant 25 years of proven field experience
(high-K stress control)
Installation does not require additional silicone tape or
grease
Kit Contents:
Superior UV stability Shorter terminal for saturated
Each kit contains the following materials necessary
spaces Ease of installation without tools
to make the monopolar cable terminations or a
tripolar termination (*): 3 insulators with high
additional
dielectric constant self-contracting silicone rubber
Designed to meet or exceed IEEE 48, VDE 0278 and
skirts. 3 constant action springs for ground
IEC 502 standards
connection. 3 tomatierra braids. 6 pieces of mastic
seal. 1 roll super 33+ vinyl tape. A CC-2 Cable
Applications:
Preparation Kit. 1 assembly instructions. (*) The
tripolar termination kits also include 3 phase
Power cable connection to equipment or transitions
isolation seals. 1 PST Trifurcation Seal.
Avoid dangerous shocks to the cable

QT-III vs. QT II:


Application Recommendations:
"Unlike the QT-II, in the QT-III the removal of
Prepare the cable according to the instructions, no
silicone grease and the integration of sealing
"pencil point" preparation is required. Install the
compounds has reduced
appropriate compression terminal in the conductor,
Significantly installer errors and reduces installation
install the earth connection according to the
time for our customers who have tested the QT-III.
instructions. Clean insulation with liquid or aerosol
The integration of these two characteristics in the
cleaners to remove contamination. Insert the
exterior and interior finishes has been very well
terminal into the wire over the mark on the
received due to the simplicity, reliability and
insulation and snap into position, remove the spiral
economy of installation. "Consult the Table of
and the terminal will contract over the wire.
Equivalences between QTII and QTIII in case of any
doubt about application.
QT-III Cold Shrink Terminations
Data sheet

Selection table and instructions


for QT-III terminals:
(for ribbon cable or copper wires).
Locate in the first column of the table the Termination
model appropriate to your requirements; Click on the
model to obtain the technical sheet.

Selection table and instructions for QT-III terminals


QT-III indoor 5kV 8kV 15kV 25kV
7621-T-95 2-3 / 0 AWG 4-2 / 0 AWG
7622-T-110 4 / 0-400 MCM 3 / 0-300 MCM 2-4 / 0 AWG
7624-T-110 500-750 MCM 350-700 MCM 4 / 0-500 MCM
7625-T-110 700-1500 MCM 600-1250 MCM 500-1000 MCM
7626-T-110 1750-2000 MCM 1500-2000 MCM 1250-2000 MCM
7693-T-150 300-500 MCM 250-500 MCM 2 / 0-300 MCM 2-4 / 0 AWG
7695-T-150 700-1500 MCM 600-1250 MCM 500-1000 MCM 250-800 MCM
7696-T-150 1750-2000 MCM 1500-2000 MCM 1250-2000 MCM 900-1750 MCM

QT-III exterior 5kV 8kV 15kV 25kV 35kV


7620-S-2 8-4 AWG 8-6 AWG
7621-S-2 2-3 / 0 AWG 4-2 / 0 AWG
7622-S-2 4 / 0-400 MCM 3 / 0-300 MCM 2-4 / 0 AWG
7692-S-4 4 / 0-400 MCM 3 / 0-300 MCM 2-4 / 0 AWG 2-1 / 0 AWG
7693-S-4 300-500 MCM 250-500 MCM 2 / 0-300 MCM 2-4 / 0 AWG
7694-S-4 500-750 MCM 350-700 MCM 4 / 0-500 MCM 2 / 0-250 MCM
7695-S-4 700-1500 MCM 600-1250 MCM 500-1000 MCM 250-800 MCM
7696-S-4 1750-2000 MCM 1500-2000 MCM 1250-2000 MCM 900-1750 MCM
7683-S-8 300-500 MCM 250-500 MCM 2 / 0-300 MCM 2-4 / 0 AWG 2-2 / 0 AWG
7684-S-8 500-750 MCM 350-700 MCM 4 / 0-500 MCM 2 / 0-250 MCM 2-4 / 0 AWG
7685-S-8 700-1500 MCM 600-1250 MCM 500-1000 MCM 250-800 MCM 3 / 0-600 MCM
7686-S-8 1750-2000 MCM 1500-2000 MCM 1250-2000 MCM 900-1750 MCM 700-1500 MCM

Inverted QT-III 5kV 8kV 15kV 25kV


7622-S-INV-2 4 / 0-400 MCM 3 / 0-300 MCM 2-4 / 0 AWG
7693-S-INV-4 300-500 MCM 250-500 MCM 2 / 0-300 MCM 2-4 / 0 AWG
7695-S-INV-4 700-1500 MCM 600-1250 MCM 350-1000 MCM 250-800 MCM
7696-S-INV-4 1750-2000 MCM 1500-2000 MCM 1250-2000 MCM 900-1750 MCM

All Kits include supplies necessary to make a 3-prong termination. In case you
require a Tripolar Kit, you just have to add a “-3” at the end of the product code. Ex:
7621-T-95-3

For more information:

Consumer Service Center

600-300-3636
E-mail: atencionconsumidor@3m.com

You might also like