11.appendix BData Used For Relevant Power System Components
11.appendix BData Used For Relevant Power System Components
283
284 APPENDIX B Data Used for Relevant Power System Components
KA 20 20 20
TA (s) 0.2 0.2 0.2
KE 1.0 1.0 1.0
TE (s) 0.314 0.314 0.314
KF 0.063 0.063 0.063
TF (s) 0.35 0.35 0.35
1 5 0.001 0.012 0
2 6 0.001 0.012 0
9 10 0.022 0.22 0.33
9 10 0.022 0.22 0.33
9 10 0.022 0.22 0.33
9 6 0.002 0.02 0.03
9 6 0.002 0.02 0.03
3 7 0.001 0.012 0
4 8 0.001 0.012 0
10 8 0.002 0.02 0.03
10 8 0.002 0.02 0.03
5 6 0.005 0.05 0.075
5 6 0.005 0.05 0.075
7 8 0.005 0.05 0.075
7 8 0.005 0.05 0.075
MVA 615 60 60 25 25
Rs (pu) 0.0031 0.0031 0.0031 0.0014 0.0014
H (s) 5.148 6.54 6.54 5.06 5.06
D (pu) 0.046 0.046 0.046 0.046 0.046
Xd (pu) 0.8979 1.05 1.05 1.25 1.25
X0 d (pu) 0.2995 0.1850 0.1850 0.232 0.232
Xq (pu) 0.646 0.98 0.98 1.22 1.22
X0 q (pu) 0.646 0.36 0.36 0.715 0.715
T 0 do (s) 7.4 6.1 6.1 4.75 4.75
T 0 qo (s) 0.3 0.3 0.3 1.5 1.5
APPENDIX B Data Used for Relevant Power System Components 287
KA 20 20 20 20 20
TA (s) 0.02 0.02 0.02 0.02 0.02
KE 1.0 1.0 1.0 1.0 1.0
TE (s) 0.19 1.98 1.98 0.70 0.70
KF 0.0012 0.001 0.001 0.001 0.001
TF (s) 1.0 1.0 1.0 1.0 1.0
Table B.11 Base Case Load Flow Data of 14-Bus Test System
Injection Generation Load
Bus
Bus Voltage Angle u Qi Pg Qg PL QL
# V (pu) ( ) Pi (MW) (MVAr) (MW) MVAr (MW) MVAr
Table B.12 Transmission Line Data of 14-Bus System on 100 MVA Base
From Series Series Shunt Actual
Bus To Bus Resistance Reactance Susceptance Tap
Number Number (Rs) (pu) (Xs) (pu) (B/2) (pu) Ratio
Table B.12 Transmission Line Data of 14-Bus System on 100 MVA Base—cont’d
From Series Series Shunt Actual
Bus To Bus Resistance Reactance Susceptance Tap
Number Number (Rs) (pu) (Xs) (pu) (B/2) (pu) Ratio
2 6 0.05811 0.17632 0.0187 1
2 7 0.05695 0.17388 0.017 1
3 6 0.06701 0.17103 0.0173 1
4 7 0 0.25202 0 0.932
4 11 0.09498 0.1989 0 1
4 12 0.12291 0.25581 0 1
4 13 0.06615 0.13027 0 1
5 8 0 0.17615 0 1
6 7 0.01335 0.04211 0.0064 1
6 8 0 0.20912 0 0.978
6 9 0 0.55618 0 0.969
8 9 0 0.11001 0 1
9 10 0.03181 0.0845 0 1
9 14 0.12711 0.27038 0 1
10 11 0.08205 0.19207 0 1
12 13 0.22092 0.19988 0 1
13 14 0.17093 0.34802 0 1
Slack bus 25.58 1.5113 0.0981 0.6845 0.646 0.2995 0.646 7.4 0.06 5.148 0.2
2 5.4 0.538 0.0981 0.3845 0.646 0.2995 0.646 7.4 0.06 5.148 0.2
3 5.4 0.785 0.0981 0.5845 0.646 0.2995 0.646 7.4 0.06 5.148 0.2
4 3.8 0.690 0.031 0.5979 0.646 0.2995 0.646 7.4 0.06 5.148 0.2
5 5.4 1.026 0.0981 0.3845 0.646 0.2995 0.646 7.4 0.06 5.148 0.2
6 3.8 0.3662 0.031 0.4979 0.646 0.2995 0.646 7.4 0.06 5.148 0.2
7 2.4 0.617 0.031 0.5979 0.646 0.2995 0.646 7.4 0.06 5.148 0.2
8 0.9 0.309 0.031 1.05 0.98 0.185 0.36 6.1 0.3 6.54 0.2
9 0.46 0.026 0.041 1.25 1.22 0.232 0.715 4.75 1.5 5.06 0.2
10 1.8 0.2623 0.031 1.05 0.98 0.185 0.36 6.1 0.3 6.54 0.2
11 2 0.3795 0.031 1.05 0.98 0.185 0.36 6.1 0.3 6.54 0.2
12 1.8 0.1241 0.031 1.05 0.98 0.185 0.36 6.1 0.3 6.54 0.2
13 2.7 1.576 0.041 0.6979 0.646 0.2995 0.646 7.4 0.06 5.148 0.2
14 0.243 0.0109 0.041 1.25 1.22 0.232 0.715 4.75 1.5 5.06 0.2
15 0.108 0.014 0.041 1.25 1.22 0.232 0.715 4.75 1.5 5.06 0.2
16 0.54 0.015 0.041 1.25 1.22 0.232 0.715 4.75 1.5 5.06 0.2
17 6.0 1.84 0.0981 0.4845 0.646 0.2995 0.646 7.4 0.06 5.148 0.2
18 0.5 0.3894 0.041 1.25 1.22 0.232 0.715 4.75 1.5 5.06 0.2
19 1.5 0.6947 0.031 1.05 0.98 0.185 0.36 6.1 0.3 6.54 0.2
20 6.0 4.20 0.0981 0.5845 0.646 0.2995 0.646 7.4 0.06 5.148 0.2
21 0.204 0.0297 0.041 1.25 1.22 0.232 0.715 4.75 1.5 5.06 0.2
22 0.225 0.0232 0.041 1.25 1.22 0.232 0.715 4.75 1.5 5.06 0.2
23 0.225 0.02 0.041 1.25 1.22 0.232 0.715 4.75 1.5 5.06 0.2
24 0.4 0.0292 0.041 1.25 1.22 0.232 0.715 4.75 1.5 5.06 0.2
289
290 APPENDIX B Data Used for Relevant Power System Components
Note: Total line ¼ 159 þ 35 (Line transformer—3 windings) þ 37 (Load transformer—2 windings) þ 35
(Load transformer—3 windings) ¼ 266. But here total 265 numbers of lines are considered during
analysis, because line 47 has been removed due to its very small impedance. Lines are arranged
according to bus voltage level.
298
APPENDIX B Data Used for Relevant Power System Components
Table B.17 Base Case Load Flow Data of 14-Area, 24-Machine, 203-Bus System
Bus No. Bus Voltage Angle Pcal Qcal Pg PL Qg QL
V (pu) θ (rad.) (MW) (MVAr) (MW) (MVAr) (MW) (MVAr)
299
300
APPENDIX B Data Used for Relevant Power System Components
Table B.17 Base Case Load Flow Data of 14-Area, 24-Machine, 203-Bus System—cont’d
Bus No. Bus Voltage Angle Pcal Qcal Pg PL Qg QL
V (pu) θ (rad.) (MW) (MVAr) (MW) (MVAr) (MW) (MVAr)
50 0.9736 0.5015 0.35 0.2169 0 0.35 0 0.2169
51 0.9708 0.5114 0.8 0.4958 0 0.8 0 0.4958
52 0.9697 0.4754 0.86 0.533 0 0.86 0 0.533
53 1.002 0.4074 0.5 0.3569 0 0.5 0 0.3569
54 0.9674 0.4672 0.8 0.4958 0 0.8 0 0.4958
55 0.9943 0.4532 0 0 0 0 0 0
56 1.0024 0.4779 0.33 0.2045 0 0.33 0 0.2045
57 0.9603 0.5074 0.4 0.2479 0 0.4 0 0.2479
58 0.961 0.484 0.53 0.3085 0 0.53 0 0.3085
59 1.0051 0.4536 0.14 0.0868 0 0.14 0 0.0868
60 1.0102 0.4113 0.32 0.21 0 0.32 0 0.21
61 0.9682 0.4881 0.31 0.1921 0 0.31 0 0.1921
62 0.9879 0.4806 0.57 0.3533 0 0.57 0 0.3533
63 0.9867 0.4616 0.25 0.1549 0 0.25 0 0.1549
64 0.9995 0.483 0 0 0 0 0 0
65 0.9786 0.5031 0.43 0.2665 0 0.43 0 0.2665
66 1.0063 0.4241 0.39 0.2417 0 0.39 0 0.2417
67 0.9892 0.4726 0.124 0.0744 0 0.124 0 0.0744
68 0.9834 0.4789 0.66 0.409 0 0.66 0 0.409
69 0.973 0.4832 0.74 0.4586 0 0.74 0 0.4586
70 0.9882 0.4718 0.41 0.2541 0 0.41 0 0.2541
71 1.0083 0.4264 0.92 0.5702 0 0.92 0 0.5702
72 1.0167 0.4635 0.52 0.3223 0 0.52 0 0.3223
73 0.9793 0.4829 2.15 1.3325 0 2.15 0 1.3325
74 1.0146 0.4331 0.68 0.4214 0 0.68 0 0.4214
75 0.9945 0.4396 0.33 0.2045 0 0.33 0 0.2045
76 0.9966 0.4183 0.4 0.2479 0 0.4 0 0.2479
301
302
APPENDIX B Data Used for Relevant Power System Components
Table B.17 Base Case Load Flow Data of 14-Area, 24-Machine, 203-Bus System—cont’d
Bus No. Bus Voltage Angle Pcal Qcal Pg PL Qg QL
V (pu) θ (rad.) (MW) (MVAr) (MW) (MVAr) (MW) (MVAr)
101 1.0184 0.4035 0 0 0 0 0 0
102 0.9847 0.4798 0.13 0.0806 0 0.13 0 0.0806
103 0.9817 0.4815 0.05 0.031 0 0.05 0 0.031
104 1.0198 0.4048 0 0 0 0 0 0
105 1.0067 0.4236 0.12 0.082 0 0.12 0 0.082
106 1.0063 0.4241 0.016 0.0087 0 0.016 0 0.0087
107 0.9968 0.4501 0.35 0.1825 0 0.35 0 0.1825
108 0.9902 0.4751 0.31 0.1921 0 0.31 0 0.1921
109 0.9853 0.4912 0.12 0.0744 0 0.12 0 0.0744
110 0.9963 0.423 0.35 0.2269 0 0.35 0 0.2269
111 1.0056 0.415 0.28 0.1935 0 0.28 0 0.1935
112 1.0119 0.3523 2 1.39 0 2 0 1.39
113 0.9724 0.4746 0.38 0.2355 0 0.38 0 0.2355
114 0.9785 0.4263 0.35 0.2169 0 0.35 0 0.2169
115 1.046 0.4236 0 0 0 0 0 0
116 1.0614 0.4118 0 0 0 0 0 0
117 1.0354 0.3744 0 0 0 0 0 0
118 1.0396 0.3585 0 0 0 0 0 0
119 1.027 0.3491 0 0 0 0 0 0
120 1.0706 0.3114 0 0 0 0 0 0
121 1.0787 0.3091 0 0 0 0 0 0
122 1.0273 0.3569 0 0 0 0 0 0
123 1.0289 0.4177 0 0 0 0 0 0
124 1.0129 0.3948 0 0 0 0 0 0
125 1.0223 0.4165 0 0 0 0 0 0
126 1.0228 0.443 0 0 0 0 0 0
127 1.015 0.4369 0 0 0 0 0 0
303
304
APPENDIX B Data Used for Relevant Power System Components
Table B.17 Base Case Load Flow Data of 14-Area, 24-Machine, 203-Bus System—cont’d
Bus No. Bus Voltage Angle Pcal Qcal Pg PL Qg QL
V (pu) θ (rad.) (MW) (MVAr) (MW) (MVAr) (MW) (MVAr)
153 1.0208 0.3992 2.5 1.8 0 2.5 0 1.8
154 1.0586 0.3255 10 6.8592 0 10 0 6.8592
155 1.0719 0.361 0 0 0 0 0 0
156 1.0928 0.226 0 0 0 0 0 0
157 1.0985 0.3579 0 0 0 0 0 0
158 1.019 0.3539 0 0 0 0 0 0
159 1.0163 0.3569 0 0 0 0 0 0
160 0.9791 0.3953 0.15 0.09 0 0.15 0 0.09
161 0.969 0.4186 0.16 0.07 0 0.16 0 0.07
162 0.9897 0.4185 0 0 0 0 0 0
163 0.972 0.4203 0.15 0.08 0 0.15 0 0.08
164 0.9822 0.4241 0 0 0 0 0 0
165 0.9883 0.466 0.33 0.18 0 0.33 0 0.18
166 0.9972 0.4768 0.35 0.18 0 0.35 0 0.18
167 0.9894 0.466 0.23 0.12 0 0.23 0 0.12
168 0.954 0.4098 0.31 0.2 0 0.31 0 0.2
169 0.9656 0.4643 0.3 0.183 0 0.3 0 0.183
170 0.9958 0.4373 0.2 0.12 0 0.2 0 0.12
171 0.9846 0.4174 0.3 0.15 0 0.3 0 0.15
172 0.959 0.462 0.35 0.23 0 0.35 0 0.23
173 0.9653 0.4976 0.35 0.15 0 0.35 0 0.15
174 0.9858 0.5093 0.38 0.181 0 0.38 0 0.181
175 0.9734 0.4851 0.13 0.05 0 0.13 0 0.05
176 0.9891 0.4604 0.48 0.28 0 0.48 0 0.28
177 0.9836 0.4829 0.25 0.154 0 0.25 0 0.154
178 0.9979 0.4241 0.1 0.05 0 0.1 0 0.05
179 0.9832 0.475 0.25 0.154 0 0.25 0 0.154
305
306 APPENDIX B Data Used for Relevant Power System Components