SWRO pre-treatment:

Integrity and
disinfection
n the second of a series of articles, Graeme Pearce looks at the
I issues involved in the selection of pre-treatment technology in
seawater reverse osmosis applications.

Background selection of pre-treatment technology drinking water treatment is disinfection.


for SWRO, and consider the case for The purpose of removing other water quality
Selection of pre-treatment technology for conventional and membrane pre-treatment parameters mainly assists disinfection or
desalination in seawater reverse osmosis options. This previous article examined the improves the subsequent stability of the
(SWRO) applications tends to polarise issue of the treated water quality for the treated water. Improvement of the aesthetic
opinion. Conventional technology RO feed, while the focus of this article is quality of the water in terms of taste, odour,
represents the status quo while membrane and appearance is a desirable side effect, but
Integrity and Disinfection. Future articles
filtration adopts the role of the challenger, of secondary importance compared to the
will cover Cost and Sustainability, and
with a rapidly developing track record. disinfection driver. Of course, if the source
Markets and Experience. The articles will
Two issues limit the wider adoption of is saline, reducing dissolved species would
focus on the comparison between pre-
membrane pre-treatment. Firstly it is also become a primary treatment objective.
treatment technologies.
considered expensive in terms of capital
cost, though it does provide operational cost In contrast, industrial water treatment
Treatment requirements usually has several treatment quality drivers,
savings. Secondly there are misgivings about
whether membrane filtration alone provides The water market is normally divided into with strict limits imposed on particulates
sufficient pre-treatment, since preparing a and dissolved species, dependent upon the
two broad categories which describe the
feed suitable for RO requires more than the application. Disinfection is then usually
customer base served, ie: the Municipal and
removal of fine particulates. applied as a final treatment stage.
Industrial segments. These two segments
This article is the second in a series which have significantly different treatment Seawater desalination does not fit neatly
will examine the issues involved in the requirements. The primary objective of into the categories described, since the

A desalination plant in Dubai.


Feature 33
Filtration+Separation January/February 2010

output of a typical desalination project may RO membrane integrity Another critical application of membranes
have several end users, both municipal and for guaranteed disinfection was developed
industrial. Treated water quality standards RO provides a reasonable degree of micro- for the microelectronics industry in the
may therefore vary, but it is likely that organism removal, but neither the RO 1980s, in which a low molecular weight
disinfection will be required since some membrane element nor the RO system ultrafiltration (UF) membranes with
of the output may well be required for is designed to provide a guaranteed a nominal molecular weight cut off of
drinking purposes. Disinfection is therefore disinfection capability. Though RO between 6k and 13k were used in a dead end
normally a critical treatment objective in membranes are almost three orders of configuration in the washwater polishing
SWRO projects. magnitude finer than the UF membranes loop of wafer fabrication processes.
used in the water industry, a typical RO
Membranes in general water treatment
Disinfection capabilities of system provides an inferior disinfection
applications differ from these examples in
conventional pre-treatment barrier. This section discusses the reasons for
that they are used in continuous processes,
this apparent anomaly.
normally operated in a dead end mode
The conventional pre-treatment processes A thin film composite membrane used for with intermittent backwash. Although the
that have traditionally been used for pre- RO is designed to reject salt at an efficiency membrane rating of UF and MF is below
treatment to RO desalination are similar of about 99% (ie: 2 LRV). If there are the size of bacterial organisms, minor
to those used in normal drinking water small defects in the flat sheet, the effect on imperfections will allow micro-organisms
treatment. Filtration processes such as removal efficiency will be small. Therefore, to pass through occasionally. Furthermore,
sand filters and multi media filters do not casting technology has developed to make the nature of the design of continuous
provide an effective physical barrier to a thin high performance active layer to processes creates infection opportunities.
micro-organisms unless used in combination achieve high salt rejection, but tolerates UF and MF processes therefore cannot
with a coagulation stage. The particle minor physical defects. When the flat sheet achieve sterilisation, but may approach
removal efficiency for an uncoagulated feed is wound into an element, the feed channel is the performance of a physical disinfection
would be typically 70-97% at 5μm, thus a sealed by the application of a glue line on the barrier, provided that they maintain their
log removal value (LRV) of 0.5-1.5. Since active layer surface. The supporting substrate integrity [4].
bacterial spoors are normally less than 1μm, is not sealed by glue penetration since the
disinfection due to physical removal by
Integrity properties of the hollow
active layer is dense rather than porous. Any
media filters is of limited value. defect in the active layer therefore has a leak fibre module
path which is not restricted to the local area Membrane filtration systems used in the
Particle removal is improved markedly by
around the defect. water industry nearly all use a hollow fibre
coagulation since particle size increases
and the flocs formed tend to stick to the Spiral elements are mounted in a pressure module format. Hollow fibre modules use
media surfaces, typically improving removal vessel with large diameter gasket seals. capillary membranes with an inside diameter
efficiency at 5μm by 1 LRV to 97-99.7%. During operation, elements move their normally in the range of 0.5-1.0 mm.
The removal of bacterial spoors and even position in the vessel, and local leaks from The configuration may supply feed to the
viruses is also improved, achieving a feed to permeate can occur. Conductivity inside of the fibre or the outside. The
sampling is used to identify the more outside feed configuration is split further
reasonable level of physical disinfection.
significant faults, but minor leakage has into pressure driven formats in which the
However, conventional drinking water
a limited effect on salt passage, and is feed side is pressurised, and submerged,
treatment relies on disinfection with
tolerated. A survey of challenge tests with in which the driving force is supplied by
chlorine as the final step, and the primary
RO elements has shown that virus removal applying a vacuum to the permeate side.
purpose of coagulation and filtration is to Figure 1 shows a pressure driven inside feed
improve disinfection efficiency. Indeed, varies widely [3]. Whereas pilot systems can
format module. In the example shown,
conventional processes rely on super achieve > 6 LRV of virus, larger systems
each of the 12 segments contains about
chlorination of surface water supplies to provide variable results, with LRVs as low
850 membrane fibres.
guarantee disinfection, necessitating the as 2 or less, and an average performance of
use of high chlorine doses and a significant around 3-4 LRV. Hollow fibre membranes have a higher
contact time. degree of manufacturing integrity, and
A disadvantage of spirals is that if an element
are produced with a relatively narrow
In addition to the use of chlorine for is found to contain a defect, it cannot be
pore size distribution. Minor defects can
disinfection, oxidation improves the repaired, but could be replaced completely if occur in the fibre wall, or there can be
efficiency of both coagulation and filtration performance was sufficiently poor. gross defects in the fibre, but these are not
processes, with the result that sometimes commonplace, and are mainly eliminated
The use of membranes for
chlorine dosing is incorporated into
disinfection
conventional pre-treatment design [1,2].
However, the problem for desalination Membrane filtration products have
processes is that thin film composite spirals, been specifically designed to provide an
which are by far the most commonly essentially complete barrier to micro-
used RO membrane, are highly sensitive organisms. Some products guarantee this
to chlorine. Oxidative attack degrades performance and are used to provide
performance and increases salt passage. a sterile filtrate. One of the earliest
Furthermore, if the pre-treated feed is commercial applications of membranes was
chlorinated and then dechlorinated, bio- for the removal of bacterial organisms in the
fouling potential is increased, as discussed bio-pharmaceutical industry in the 1950s.
in the final section. Conventional pre- These microfiltration (MF) membranes
treatment therefore does not provide a were used in a dead end configuration, and
disinfected feed supply to the RO, and provided a guaranteed removal of organisms
the option of chlorine use is likely to at 0.22 μm and 0.45 μm, producing a Figure 1: Hollow fibre module cut away to expose
be detrimental. sterilised filtrate. internal fibre bundle and structure.
34 Feature
Filtration+Separation January/February 2010

Fibre integrity failure modes


Fibre integrity problems can occur in
UF or MF hollow fibre modules due to
manufacturing defects, or defects caused by
problems in process design or operation.
Defects during manufacture are normally
identified in a final stage integrity test,
and repaired by pinning. A typical module
of many thousand fibres may have one or
two fibres pinned in the manufacturing
integrity check. Figure 4: Bio-fouling on an SEM slide post
dechlorination
With regard to operational issues, a major
problem is failure of the strainer system
(which will result in damage to the feed side
By using a monitoring programme,
of the fibre). Another operational problem
membrane filtration can provide a secure
is contamination of the permeate system.
Figure 2: Diagrammatic axial section of a hollow integrity barrier for water treatment
fibre module. Integrity problems caused by particulates in
applications. The barrier can be tested,
the system and/or fibre weakness will tend
and if necessary repairs can be performed
to be exacerbated by over-pressurisation and
to ensure that the barrier is maintained.
water hammer. If valve sequencing is not
by integrity testing and repair at the end of Without membrane pre-treatment,
carefully controlled, pressure spikes can be
the manufacturing process. Figure 2 shows a desalination system would rely on
transmitted to the membranes.
a diagrammatic cross section of a pressure disinfection by chlorine of the final treated
driven outside feed module, illustrating the water, and depending on the source,
Integrity verification
potting interface at the top and bottom of may even need super chlorination. With
the module which provides the seal between Verification of membrane integrity is an membrane pre-treatment, the membrane
feed and filtrate side of the membrane. important issue for UF and MF technologies, pre-treatment stage alone provides physical
since the provision of a barrier to micro- disinfection, which reduces the reliance on
The design of the hollow fibre module final disinfection by chlorine and improves
preserves the intrinsic integrity of the organisms is often the reason for selecting
a membrane filtration process. The most the operation of the RO.
membrane fibre using a potting material to
seal the fibre with epoxy or other sealing common approach is to monitor filtrate
quality continuously, and to conduct an Bio-fouling
compound. The potting material is able to
penetrate the fibre completely since the occasional off-line pressure hold test.
Bio-fouling is one of the most difficult
UF/MF membrane is porous and allows Turbidity monitoring is not sensitive enough
problems for an RO system, especially with
the epoxy to flow through the membrane to be a reliable indicator of integrity, and
warm feeds, above say 25oC. Bacteria are
wall. Therefore, if there is a defect in the is not able to detect breaches that would
always present in a desalination system,
active layer of the membrane, the leak reduce micro-organism removal below
since even the finest pre-treatment rating
path to the product side is eliminated specification. However, it is inexpensive
will occasionally allow bacteria to pass due
by epoxy penetration of the supporting and reasonably reliable, and does provide
to defects or from damage leading to loss
membrane layer. some indication of changes in membrane
of integrity. If bacteria have a food source
performance.
Figure 3 shows a cross section through colonies will develop and bio-film will grow.
the potting at the top of the module. The The off-line tests are mainly based on the It is therefore best to adopt a strategy of
diagram illustrates a successful potting principle that water in membrane pores is management and control rather than expect
on the left hand side, in which epoxy has held in situ by surface tension and capillary to eliminate bacteria completely. With
penetrated through the membrane support forces. The air pressure required to displace the correct operating conditions, it should
layer to provide a pale colouration through the water is known as the bubble point [4]. be possible to avoid the worst effects of
the fibre wall. In contrast, the right hand The most widely used of these tests is the bio-fouling.
side illustrates an unsuccessful potting, Pressure Decay Test.
An important requirement of pre-treatment
which could occur if the epoxy was too is to avoid the presence of oxidising
viscous, or the active layer of the membrane compounds. A chlorine residual has a
too dense. In this example, the potting straightforward detrimental effect, rapidly
material has not penetrated through the degrading the membrane and increasing
fibre wall creating a potential leak path salt passage. However, a Cl2 residual
between feed and filtrate side should the anywhere upstream of the RO may also be
active layer contain any defects. Sometimes damaging, even if destroyed by a reducing
early stage products from UF and MF agent prior to the RO, as shown in Figure
modules manufacturers have contained some 4 [5]. Breakdown products of Cl2 and high
unpenetrated zones, but this is a problem molecular weight organic molecules are
that has been eliminated in established likely to form assimilable compounds, which
commercial products. are a nutrient source for bacteria, thus
In module construction, some manufacturers stimulating bio-fouling.
manage to eliminate ‘o’ ring seals In addition, the use of oxidants to disinfect
completely to enhance integrity even and control established bio-fouling may
further; if used, the key seal is much smaller provide only a temporary reprieve since, if
in diameter than in the spiral element successful, the dead bacteria will provide
system, and a double ‘o’ ring seal is used for Figure 3: Diagrammatic radial cross section through the a nutrient source for new colonisers [6].
increased security. hollow fibre potting. However in all likelihood, surface bacteria
Feature 35
Filtration+Separation January/February 2010

on chlorination, and potentially super


chlorination, to achieve disinfection of
the final treated water.

• Membrane pre-treatment provides a


physical disinfection barrier to the RO,
ensuring a superior feed quality and
reducing reliance on final chlorination.
• Membrane filtration modules can be
tested for integrity, and if necessary
repaired, to ensure that the integrity
barrier is maintained.
• Chlorine is sometimes used to enhance
the performance of conventional pre-
treatment, but increases the risk of bio-
fouling; membrane pre-treatment does
not require pre-chlorination of the feed,
and therefore minimises this risk.

References
[1] Properly designed conventional pre-
treatment provides suitable water quality for
RO Jacangelo, J G, Grounds, J, Desalination
and Water Reuse 13/4 (2003) 16-23
[2] SWRO pre-treatment: Choosing between
conventional and membrane filtration
Voutchkov, N, Desalination (a Filtration &
Separation publication), 4/1 (2009) 5-8
[3] Reverse osmosis integrity monitoring
Kumar, M, Adham, S, DeCarolis, J,
Desalination, 214 (2007) 138-149
[4] Membrane Filtration Guidance Manual
Alspach, B (Malcolm Pirnie), Vickers, J
(SPI), EPA 815-D-03-008 (June 2003)
[5] Biofouling in a Seawater RO Plant on
the Red Sea Coast, Saudi Arabia Saeed, M
O, Jamaluddin, A T, Tisan, I A, Conference
Proceedings, IDA San Diego, Vol 2 Ref 1131
(1999) 207-221
[6] Bio-fouling: Open questions, insufficient
solutions, innovative approaches Conference
Proceedings, EDS Baden Baden, 281
(May 2009)
[7] An Overview of the 150,000 m3/day
There are many issues involved in selecting pre-treatment technology for desalination in seawater reverse
Beckton Desalination Plant in London
osmosis applications. Moore, B J, Malfeito, J J, Conference
Proceedings, IDA Dubai, (2009)
will protect internal members of the colony oxidant to provide a disinfection residual,
to some extent, enabling rapid re-growth but is not strong enough to form AOC, In the first SWRO pre-treatment article
soon after the disinfection procedure. thereby depriving bacteria of nutrient. in the November/December 2009 issue,
Bio-fouling control therefore benefits Although RO membranes have somewhat Figure 1 (page 30) was adapted from
from a carefully developed strategy of greater tolerance to ClO2 than Cl2, it images originated by Dr. Steve Tarleton,
accommodation and limitation rather than is unlikely that a full residual could be Department of Chemical Engineering,
attempts to eliminate it completely. used (as for example with chloramines
in wastewater reuse applications). The
Loughborough University, UK. •
One of the strategies to control bio-fouling optimum methodology to take advantage
Contact:
is to use shock chlorination, ie: a high Cl2 of this option has still to be developed,
Dr Graeme K Pearce,
dose on an occasional basis. This strategy but membrane pre-treatment allows the Membrane Consultancy Associates
is moderately effective in slowing down the potential to use less aggressive strategies E-mail: gpearce@membraneconsultancy.com
rate of bio-fouling, but does not eliminate especially if combined with coagulation. www.membraneconsultancy.com
the problem. Another strategy is to use The author has contributed the sections on
chlorine dioxide rather than Cl2 [7]. This Conclusions membrane filtration in The Guidebook to
relatively new concept has shown promise Membrane Desalination Technology and The
on a limited number of plants where it has • Conventional pre-treatment is often Guidebook to Membranes in Wastewater
been used. ClO2 is a sufficiently powerful used for seawater RO systems, but relies Reclamation.