Heat Exchanger Specification Sheet Thermal NEC Units
Heat Exchanger Specification Sheet Thermal NEC Units
Job No.
Customer Reference No.
Address Proposal No.
Plant Location Date 2/5/2017 Rev
Service of Unit Item No.
Size 387.00 - 774.00 x 3499.96 mm Type BKU Horz. Connected In 1 Parallel 1 Series
Surf/Unit (Gross/Eff) 28.19 / 27.84 m2 Shell/Unit 1 Surf/Shell (Gross/Eff) 28.19 / 27.84 m2
PERFORMANCE OF ONE UNIT
Fluid Allocation Shell Side Tube Side
Fluid Name 49-200
Fluid Quantity, Total kg/hr 26036.2 2076.83
Vapor (In/Out) 1672.50 21715.9 2076.83
Liquid 24363.7 4320.35 2076.83
Steam 2076.83
Water 2076.83
Noncondensables
Temperature (In/Out) C 107.14 107.75 150.29 149.79
Specific Gravity 0.4345 0.4347 0.9176
Viscosity mN-s/m2 0.0112 V/L 0.0782 0.0112 V/L 0.0781 0.0140 0.1827
Molecular Weight, Vapor
Molecular Weight, Noncondensables
Specific Heat kJ/kg-C 2.6484 V/L 3.742 2.6508 V/L 3.745 2.3986 4.3098
Thermal Conductivity W/m-C 0.0268 V/L 0.055 0.0269 V/L 0.055 0.0308 0.6841
Latent Heat kJ/kg 215.984 217.103 2112.74 2114.29
Inlet Pressure bar 20.160 4.799
Velocity m/s 0.29 11.00
Pressure Drop, Allow/Calc bar 0.050 0.011 0.500 0.064
Fouling Resistance (min) m2-K/W 0.000350 0.000170
Heat Exchanged MegaWatts 1.2196 MTD (Corrected) 42.3 C
Transfer Rate, Service 1035.64 W/m2-K Clean 5295.46 W/m2-K Actual 1320.61 W/m2-K
CONSTRUCTION OF ONE SHELL Sketch (Bundle/Nozzle Orientation)
Shell Side Tube Side
Design/Test Pressure barG 24.000 / 24.000 /
Design Temperature C 220.00 220.00
No Passes per Shell 1 2 387
mm
Corrosion Allowance mm
Connections In mm 1 @ 154.100 1 @ 90.100 3.5
m