Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 6

OIL REFINERY PLANT Rev.

0
SOLEIMANIEH, IRAQ Job: HIDECo. - …
VACUUM DISTILLATION UNIT Page 1 of 5
MAHSHAHR PIPE PROTECTION
COMPANY (MPPC)

LVGO WATER COOLER


DATA SHEET
E-0107

HADISH IDEA DEVELOPERS


ENGINEERING COMPANY

0 25.06.2014 Issued for Review M.H SH.J GH.B


REV. DATE DESCRIPTION PREPARED CHECKED APPROVED
Information contained herein is our property and must not be used by or conveyed to any person without our authority, HIDECo
OIL REFINERY PLANT
Rev. 0
SOLEIMANIEH, IRAQ
Job: HIDECo. - …
MAHSHAHR PIPE VACUUM DISTILLATION
Page 2 of 5
PROTECTION COMPANY UNIT
(MPPC)

SHELL AND TUBE HEAT EXCHANGER DATA SHEET Rev.

1 SERVICE LVGO Water Cooler ITEM E-0107


2 SIZE 550 x 5600 mm TEMA TYPE AES POSITION Horizontal
3 No. OF UNIT 1 SURFACE PER UNIT 89.2 / 85.9 m² SURFACE PER ELEMENT 89.2 / 85.9 m²
4 ELEMENT PER UNIT 1 CONNECTION: IN PARALLEL 1 x 1 IN SERIES MANUFACTURER
5 PERFORMANCE DATA OF ONE UNIT (CASE: )
6 SHELL SIDE TUBE SIDE
7 FLUID CIRCULATED LVGO Cooling Water
8 TOTAL FLUID ENTERING kg/h 34125.8×1.1 30110.5×1.1
9 IN OUT IN OUT
10 VAPOURS / (MOL. WT.) kg/h / / / /
11 LIQUID kg/h 34125.8×1.1 34125.8×1.1
12 STEAM kg/h
13 WATER kg/h 30110.5×1.1 30110.5×1.1
14 OTHER VAPORS / (MOL.WT.) kg/h / / / /
15 HYDROGEN VAPORS kg/h
16 TEMPERATURE °C 63 45 35 45
17 DENSITY at T and P LIQ. / VAP. kg/m³ 807.3 / 820 / / /
18 VISCOSITY at T and P LIQ. / VAP. mPa·sec 0.7 / 0.870 / / /
19 SPECIFIC HEAT LIQ. / VAP. kJ/(kg·°C) 2.075 / 1.987 / / /
20 THERMAL CONDUCTIVITY LIQ. / VAP. W/(m·°C) 0.144 / 0.148 / / /
21 SURFACE TENSION mN/m
22 CRITICAL TEMP. / PRES. °C / bar / / / /
23 LATENT HEAT kJ/kg
24 INLET PRESSURE bar(g) 6.30 4.5
25 PRESSURE DROP ALLOW. / CALC. bar 0.50 / 0.06 0.7 / 0.6
26 FOULING RESISTANCE m²·°C/W 0.000528 0.00034
27 TYPE OF CLEANING MAINTENANCE NONE X MECH. CHEMICAL NONE X MECH. CHEMICAL
28 HEAT EXCHANGED 349×1.1 kW
29 TRANSFER RATE IN SERVICE / CLEAN 428.6 / 745.4 W/(m²·°C) MTD (CORRECTED) 10.4 °C
30 CONSTRUCTION OF ONE SHELL
31 DESIGN / TEST PRESSURE bar(g) 11.5 (3) / 8.8 (3) /
32 DESIGN TEMPERATURE °C 100 120
33 M.D.M.T. AT PRES. OF (1) °C / bar -10 / DP -10 / DP
34 CORROSION ALLOWANCE mm (5) (5)
35 No. OF PASSES PER SHELL 1 6
36 PIPE PER UNIT IN / OUT DN RATING(8) 4" / 4" 150# 4" / 4" 150#
37 NOZZLE: INLET / OUTLET DN 1x4" / 1x4" 1x4" / 1x4"
38 PARTICULAR SERVICE
39 DIFFERENTIAL PRESSURE FOR TUBE BUNDLE bar
40 SIDE CHANGE ALLOWABLE YES NOREQUIRED OVERDESIGN % ON DUTY AND FLOW RATES SURFACE
41 THIS EXCHANGER IS JOINED WITH CODE ASME TEMA CLASS R
42 (1) MINIMUM DESIGN METAL TEMPERATURE
43 NOTES
44 (2) NIOEC standards to be followed.
45 (3) Both shell and tube side to be designed for steam-out with LP steam in 205 °C and 0.5 barg.
46 (4) Exchanger inlet/outlet pipe size and rating. Flang rating should be checked by mechanical department.
47 (5) corrosion allowance will be specified by mechanical department.

Information contained herein is our property and must not be used by or conveyed to any person without our authority,
HIDECo
OIL REFINERY PLANT
Rev. 0
SOLEIMANIEH, IRAQ
Job: HIDECo. - …
VACUUM DISTILLATION
MAHSHAHR PIPE PROTECTION Page 3 of 5
UNIT
COMPANY (MPPC)

SHELL AND TUBE HEAT EXCHANGER DATA SHEET Rev.

1 CONSTRUCTION OF ONE SHELL


2 TUBE No. 266 O.D. 19.05 mm THICKNESS 2.11 mm LENGTH 5600 mm
3 TUBE PITCH 25.4 mm 30° 60° X 90° 45° U-BEND SUPPORT TYPE
4 SHELL TUBE I.D. 550 / mm OTL 511.176 mm
5 CROSS BAFFLE TYPE single-seg No. 16 C / C SPACING 310 mm CUT: 29 % PARALLEL X PERPEND.
6 IMPINGEMENT PROTECTION SEALING STRIPS PAIRS No. SEALING RODS No.
7 FACE JOINT CONSTRUCTION: SHELL SIDE TUBE SIDE
8 TUBE / TUBE-SHEET JOINT TYPE INSULATION: SHELL CHANNEL
9 MATERIALS
10 TUBES ADMIRALTY (71 CU, 28 ZN, 1 SN) TYPE CROSS BAFFLES
11 SHELL CS SHELL COVER
12 CHANNEL CS CHANNEL COVER
13 TUBE SHEET Naval Brass FLOATING HEAD COVER
14 GASKETS: SHELL FLTG. HEAD CHANNEL
15 PROVIDE SR: CHANNEL BUNDLE SHELL PROVIDE XR: CHANNEL SHELL
16 ADDITIONAL INFORMATION FOR FIXED TUBE SHEET TYPE ONLY
17 INLET PRES. bar(g) INLET TEMP. °C DESIGN LIFE
DIFFERENT CONDITIONS FROM NORMAL RUN
18 SHELL SIDE TUBE SIDE SHEEL SIDE TUBE SIDE CYCLES No.
19
20
21
22
23
24
25 MECHANICAL DESIGN DATA
26 EXPANSION JOINT: YES NO BY MFR. MATERIAL
27 MEAN METAL TEMPERATURE SHELL TUBES TUBE SHEET LIFE CYCLES No.
28 NORMAL OPERATION °C
29 °C
30 °C
31 °C
32 NOTES
33 (6) For thermowell and pressure indicator on shell & tube nozzles refer to NIOEC-SP-44-01
34
35
36
37
38
39
40
41
42
43
44
45
46
47

Information contained herein is our property and must not be used by or conveyed to any person without our authority,
HIDECo
OIL REFINERY PLANT Rev. 0
SOLEIMANIEH, IRAQ Job: HIDECo. - …
MAHSHAHR PIPE PROTECTION VACUUM DISTILLATION UNIT Page 4 of 5
COMPANY (MPPC)

SHELL AND TUBE HEAT EXCHANGER DATA SHEET Rev.

1 PHYSICAL PROPERTIES - HOT FLUID (CASE: )


2 POINT No. 1 2 3 4 5 6 7 8 9 10
3 TEMPERATURE °C 63.0 60.75 58.5 56.25 54 51.75 49.5 47.25 45.0
4 PRESSURE bar(g) 4
5 VAPOR WEIGHT FRACTIO wt % 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
6 REFERENCE DUTY kW 0 -44.1 -88.0 -131.7 -175.2 -218.4 -261.4 -304.1 -346.6
7 LIQUID
8 DENSITY kg/m³ 806.8 808.5 810.1 811.7 813.3 815.0 816.6 818.2 819.8
9 VISCOSITY mPa·sec 0.699 0.718 0.737 0.757 0.777 0.799 0.821 0.844 0.868
10 SPECIFIC HEAT kJ/(kg·°C) 2.075 2.064 2.053 2.043 2.032 2.021 2.010 2 1.987
11 THERMAL CONDUCTIVITY W/(m·°C) 0.144 0.145 0.145 0.145 0.146 0.146 0.147 0.147 0.148
12 CRITICAL TEMPERATURE °C
13 CRITICAL PRESSURE bar(g)
14 SURFACE TENSION mN/m
15 VAPOR
16 DENSITY kg/m³
17 VISCOSITY mPa·sec
18 SPECIFIC HEAT kJ/(kg·°C)
19 THERMAL CONDUCTVITY W/(m·°C)
20 PHYSICAL PROPERTIES - COLD FLUID (CASE: )
21 POINT No. 1 2 3 4 5 6 7 8 9 10
22 TEMPERATURE °C
23 PRESSURE bar(g)
24 VAPOR WEIGHT FRACTIO wt %
25 REFERENCE DUTY kW
26 LIQUID
27 DENSITY kg/m³
28 VISCOSITY mPa·sec
29 SPECIFIC HEAT kJ/(kg·°C)
30 THERMAL CONDUCTIVITY W/(m·°C)
31 CRITICAL TEMPERATURE °C
32 CRITICAL PRESSURE bar
33 SURFACE TENSION mN/m
34 VAPOR
35 DENSITY kg/m³
36 VISCOSITY mPa·sec
37 SPECIFIC HEAT kJ/(kg·°C)
38 THERMAL CONDUCTVITY W/(m·°C)
39 NOTES
40 HOT FLUID: THE DEW POINT IS REFERRED TO POINT No. ; THE BOILING POINT IS REFERRED TO POINT No.
41 COLD FLUID: THE DEW POINT IS REFERRED TO POINT No. ; THE BOILING POINT IS REFERRED TO POINT No.
42
43
44
45
46
47

Information contained herein is our property and must not be used by or conveyed to any person without our authority, HIDECo
OIL REFINERY PLANT Rev. 0
SOLEIMANIEH, IRAQ Job: HIDECo. - …
MAHSHAHR PIPE PROTECTION VACUUM DISTILLATION UNIT Page 5 of 5
COMPANY (MPPC)

Information contained herein is our property and must not be used by or conveyed to any person without our authority, HIDECo

You might also like