Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

International Journal of Engineering Trends and Technology (IJETT) - Volume4Issue5- May 2013

Design of a Wearable System for Interactive


Caption and Posture Recognition Using Wireless
Sensor Networks
K. Sreenivasa Ravi 1, G. Sowmya Bala 2, B. Venkataramanaiah 3, K. Prathyusha 4
1
Professor, ECM Dept., KL University, Guntur Dist., INDIA
2, 4
Assistant Professor, ECM Dept., KL University, Guntur Dist., INDIA
3
Research Scholar, ECM Dept., KL University, Guntur Dist., INDIA

Abstract: This paper explains the designing of a novel wearable One genuine effort towards the development of totally
system with the interactive posture caption and recognition integrated textile based temperature sensor was carried out by
functions based on the Non-vision over the ZigBee Wireless Sensor Locher, et al., in 2005 at ETH, Zurich [2]. They developed a
Network. It is very difficult to have the posture information of woven temperature sensor by integrating, insulated copper
patients those who are under coma; paralysis etc., is very difficult
wires into warp and weft along with polyester yarn, and
task. So, in this project a Non vision based different wearable type
sensors (3-axis accelerometer, heartbeat, Body temperatures devising a special routine technique for making interconnection
sensor) that are placed at patient body for collecting the postures points. However in the accuracy analyses, errors associated
information and activity are used and this will be directly with the effect of environmental parameters e.g. strain or
monitored through a computer. For data transmission ZigBee- moisture were not considered. Further the sensors were only
WSN technology is adopted. Around 28 kinds of hand postures tested in steady state conditions at some specific temperature
and 13 kinds of leg postures can be distinguish by using this points in laboratory. Finally developing interconnecting points
system. When the transmitting distance is less than 30 M and the in sensor patch is manual and cumbersome process which is
package correct transmitted rate is more than 97.5%, the real- itself a source of error towards the sensing characteristics [1].
time body interactive postures of approximately 8 persons can be
The body temperature detecting sensor prototype belt was first
monitored simultaneously by the data-controlling center. Using
this system the doctors can get the required information regarding used by the NICU of MMC hospitals. The prototype belt was
the patients of that kind and can be able to give appropriate tested on a premature infant, born after 30 weeks gestation in
treatment to the patients in correct time. stable health condition. A neonatologist and an NICU nurse
from MMC were present during the testing. After obtaining
Keywords --- ZigBee, WSN, Heart beat sensor, Body temperature permission of the parents, the prototype belt was placed on the
sensor, ARM Micro Controller neonate’s body. The belt was tested for a period of 45 minutes
on the baby to see whether the signals from the belt remained
I. LITERATURE SURVEY stable for a longer period when a baby wears the belt [3].

Because of medical mistakes every year at-least 98,000 Early models consisted of a monitoring box with a set of
people are losing their lives in United States as per the survey electrode leads which attached to the chest. The first
done by U.S. Institute of Medicine and treatment. According to wireless EKG Heart rate monitor was invented in 1977 as a
an investigative report called “Dead By Mistake” released by training aid for the Finnish National Cross Country Ski team
the Hearst Corporation, an estimated 200,000 Americans will and as 'intensity training' became a popular concept in athletic
lose their lives in 2009 alone due to preventable medical errors circles in the mid-80s, retail sales of wireless personal heart
and hospital infections [5]. There was a rapid growth of monitors started from 1983-Bui Cac [5]. First results of a fiber
wireless networking in the past several years, which mainly optic sensor for measurement of heart rate which is developed
focus on high-speed communications, and relatively long range within the European research project and is supported by the
applications such as the IEEE 802.11 Wireless Local Area EU 7th Framework Programme and develops an advanced
Network (WLAN) standards [5]. personal protective equipment (PPE) system that will ensure
active protection and information support for personnel
The first well known standard focusing on Low-Rate operating in high risk and complex environments in fire
Wireless Personal Area Networks (LR-WPAN) was Bluetooth. fighting, chemical and mining rescue operations [1].
However it has limited capacity for networking of many nodes. The core of the project is the development of advanced
There are many wireless monitoring and control applications in materials and sensors to be used for a multifunctional PPE. This
industrial and home environments which require longer battery includes real-time monitoring of risk factors (temperature, gas,
life, lower data rates and less complexity than those from oxygen level, etc.), user health status (body temperature,
existing standards. For such wireless applications, a new respiratory rate, heart rate). All prototypes will be tested in field
standard called IEEE 802.15.4 has been developed by IEEE. tests. For monitoring of the user health status intelligent
The new standard is also called ZigBee, when additional stack underwear based on fiber optic sensors and small portable
layers defined by the ZigBee Alliance are used [5]. monitoring units will be developed. The sensor development
has a special focus on using POF, as fiber optic sensors based

ISSN: 2231-5381 http://www.ijettjournal.org Page 1418


International Journal of Engineering Trends and Technology (IJETT) - Volume4Issue5- May 2013

on POF take advantage of its high elasticity and high transmitter section, the accelerometer sensor, Temperature
breakdown strain. Because of their outstanding elastic sensor, Heart beat sensor are been used. The accelerometer
properties, POF are well suited for integration into medical sensor is MMA 726Q which is a 3-axis accelerometer, which is
textiles. Another highly important criterion for selecting POF as used to measure the acceleration of an object in general the
a medical sensor is its biocompatibility, especially in case of body movement of a patient is monitored and the body angle
fiber breakage [4]. position is measured through which the timely information
regarding the patient with respect to their body movement is
II. INTRODUCTION detected and send to the main controller.

The past several years have witnessed a hasty growth in the The data collected by this is of analog data which is
wireless network part. So far wireless networking has been transmitted to the microcontroller through the ADC as shown in
paying attention on high-speed and long range purpose. On the the figure. The micro controller sends the same information
other hand, there are many wireless monitoring and control through the transmitter to the receiver placed in the equipment
applications for industrial and home environments which present at the corresponding doctor.
require longer battery life, lower data rates and less complexity
than those from existing standards and must be a globally The transmitter section also consists of the temperature
denned standard that meets the requirement for reliability, sensor and the heartbeat sensor, to get the updated information
security, low power and low cost. For such wireless regarding the health condition of the patient. Within a narrow
applications a new standard called ZigBee has been developed range of values the human body temperature will varies and can
by the ZigBee Alliance based upon the IEEE 802.15.4 standard be measured from different parts of the body. There are various
[13].The devices could include telephones, hand-held digital factors on which this temperature depends, for example level of
assistants, sensors and controls located within a few meters of activity, time of day, and psychological factors and also
each other and purge the use of physical data buses like USB depends on whether the patient is ingestion. A normal
and Ethernet cables [9, 10]. temperature range of a human body is around 37°C [5].

The target networks consist of a large range of devices The sensor is small and can be placed anywhere on the
with low data rates in the Industrial, Scientific and Medical body, which measures the temperature ranging from 0°C to
(ISM) radio bands, with building-automation controls like 50°C. This results in fast response time and low power
intruder/fire alarms, thermostats and remote (wireless) dissipation that makes it ideal for such medical application.
switches, video/audio remote controls. In this paper a novel
wearable system is designed with the interactive posture A. Working Procedure:
caption and recognition functions based on the Non-vision over
the ZigBee Wireless Sensor Network. Current progresses in The main sections for the proposed systems are
sensor technologies and wireless communication technologies
facilitate the establishment of a novel creation of healthcare a. Transmitter section (figure 1a).
monitoring systems with wearable electronics. In this project, b. Receiver section (figure 1b).
the health status of the patient is monitored continuously by
placing sensors i.e., sensor to detect the body temperature and a. Transmitter section consists of microcontroller to which
heart beat detecting sensors, along with MEMS accelerometer MEMS, Temperature sensor LCD and ZigBee are
according to the instructions given by the microcontroller interfaced. The power to this transmitter section is supplied
inbuilt in the device. from power supply circuit.

The MMA7260Q is 3-axis accelerometer. Accelerometer b. Receiver section consists of ZigBee receiver interfaced to
measures acceleration i.e., change in speed of anything that it's PC through RS 232 the power to this Receiver section is
mounted on. As gravity causes all objects to step up towards
supplied from mains.
the earth, accelerometers are versatile for determining the
orientation of an object relative to the earth. In order to
determine how level an object, a two-axis accelerometer can be
used. This would determine a body's angle from the X and Y
accelerations on the body [9, 10]. The complete working Basic principle of operation is as follows:
principle is described in detail in the below sections. Section 3
consists of the hardware description and section 4 consists of 1. First switch ‘ON’ the power supply on both sections.
the discussion and results projected in the form of a flow chart 2. The LED present on the board glows indicating that the
and finally the last sections conclude the paper. proper power supply is being supplied to the ARM
Microcontroller
III. HARDWARE DESCRIPTION 3. At first the title will be displayed on the LCD such as
“Design of a wearable system for Interactive Caption and
The basic principal of operation is clearly explained in this Recognition Postures”.
section. The figure-1 represents the basic transmitter section,
and the receiver section is represented in the figure-2. In the

ISSN: 2231-5381 http://www.ijettjournal.org Page 1419


International Journal of Engineering Trends and Technology (IJETT) - Volume4Issue5- May 2013

4. The MEMS is put on a movable part of the patient’s body The heart beat sensor as shown in the figure 2 is designed to
to know his position status whenever the patient has moved give digital output of heat beat when a finger is placed inside it.
or even fallen down suddenly. When the heart detector is working, the top-most LED flashes
in unison with each heart beat. This digital output can be
connected to microcontroller directly to measure the ‘Beats Per
Regulated Power Supply
Minute’ (BPM) rate. It works on the principle of light
modulation by blood flow through finger at each pulse.
3-axis
accelerometer
Sensor ADC The sensor consists of a super bright red LED and light
Micro ZigBee detector. The LED needs to be super bright as the light must
Controller pass through finger and detected at other end. Now, when the
heart pumps a pulse of blood through the blood vessels, the
Temperature ADC
Sensor RS232 Interfacing
finger becomes slightly more opaque and so less light reached
the detector. With each heart pulse the detector signal varies.
This variation is converted to electrical pulse. This signal is
ARM amplified and triggered through an amplifier which outputs
Heart Beat Sensor
Controller LCD Driver LCD +5V logic level signal. The output signal is also indicated on
LPC2148 top by a LED which blinks on each heart beat. Figure 2 show
the circuit of Heart Beat Sensor.
Crystal Oscillator

LED Indicator
The communication is done by means of the serial
communication. RS232 is a recommended standard; it is a
Reset Button
cable in which serial communications can be done. Information
being transferred between data processing equipment and
peripherals is in the form of digital data which is transferred in
Figure 1(a): Block diagram of Transmitter section
either a serial or parallel mode [9]. Parallel communications are
used mainly for connections between test instruments or
5. The temperature sensor is put to the finger of the patient to
computers and printers, while serial is often used between
know the body temperature of the patient. computer and other peripherals [13].
6. These recorded details are transmitted to the receiver
section through the ZigBee transmitter

ZigBee Battery Power


Supply

RS232
Interface

Figure 2: Heart Beat Sensor


Computer
The microcontroller used in proposed system is ARM
LPC2148 which is a 64 pin Micro Controller that comes under
processor core architecture ARM7TDMI-S ARM 7 version of
Figure 1(b): Block diagram of Receiver section ARM processors. It is a 32 bit Micro Controller, intended for
7. At the Receiver section, it receives the data through high end applications involving complex computations that
ZigBee receiver which is in turn interfaced to PC through follow the enhanced RISC architecture with high performance
and very low power consumption. It has serial communications
RS 232.
interfaces ranging from a USB 2.0 Full Speed device, multiple
8. The concerned data that was already recorded gets UARTS, SPI, and I2Cs. Various 32-bit timers, dual 10-bit
displayed on the PC. ADC(s), single 10-bit DAC, PWM channels and 45 fast GPIO
lines with 9 interrupt pins [11]. The Crystal Oscillated is used
The Temperature Sensor LM35 sensor series are precision to measure the frequency variations of all signals and Reset
integrated-circuit temperature sensors, whose output voltage is button is to reset the entire process to its initial state.
linearly proportional to the Celsius (Centigrade) temperature.

ISSN: 2231-5381 http://www.ijettjournal.org Page 1420


International Journal of Engineering Trends and Technology (IJETT) - Volume4Issue5- May 2013

The MMA7260Q is 3-axis accelerometer as shown in V. ADVANTAGES AND DISADVANTAGES


figure 3. An accelerometer measures acceleration (change in
speed) of anything that it's mounted on. With a three-axis The following are the few advantages and disadvantages
accelerometer, it is possible to measure an object's acceleration resulted out of the above specified proposal.
in every direction [10]. This three-axis accelerometer is
essentially a carrier board or breakout board for free scale’s Advantages:
MMA7260QT MEMS (micro-electro-mechanical systems)  Real time monitoring of health status of a person (coma,
accelerometer. The MMA7260QT is a great IC, but is small, paralysis persons).
leadless package. The device also operates at 2.2 V to 3.6 V,  Wireless communication using ZigBee technology.
which can make interfacing difficult for microcontrollers  Long life.
operating at 5 V. This carrier board addresses both issues while  Highly sensitive wireless interface.
keeping the overall size as compact as possible [9, 11].  Easy to install.
 Low power Consumption.

Disadvantages:
 Interfacing of sensors like flex sensor to microcontroller
is highly sensitive
 Heart beat sensor takes delay time to get the heart rate of
the patient instantly.

VI. CONCLUSION

This paper mainly focus on designing a system that is


aiding the helpless patients by monitoring their health condition
time to time and updataing the same information so far
collected using this proposed system for a doctor so that they
response immediately and the patient will also get a fast
Figure 3: MEMS sensor MMA7260Q [9] recovery comparitively. A lot of research is still going on to
develop a very cost effecive solution for such problems due to
such patients. In this paper a wearable system for interactive
IV. FLOW CHART REPRESENTATION capture and posture recognization system is proposed. The
proposed system mainly consist of three important devices that
The flow chart in figure 4 below explains the basic events are Heart Beat Sensor, Temperature Sensor, MMA7260Q is 3-
that occur in general while working with the above said axis accelerometer helps in monitoring the health status of a
prototype. The basic events are of three types these are related patient based on various parameters. The complete working
to the data processing values. The data here is the information principle is described in details in the above sections. The
collected from the patient (human body) through the devices transmitter and the receiver sections of the proposed system are
incorporated in the prototype i.e., accelerometer, temperature defined clearly in the section 3. The working principle of the
sensor, and the heart beat sensor. proposed system clearly explains the process through which a
patient is to be monitored and the updating of the same near the
Therefore MEMS, TEMP, HB are data receives, it receives doctor. This not only helps to get the patients health status but
data from patient (human body) and transmits the same using a also using this system it is possible to give a better treatment to
connector to the main processing unit which is then a patient by immediately responding to him. This makes
acknowledged after checking the total data it received by possible for a patient to recover soon. This system is very cost
sending a program command “Received data is complete effective solution. It is very efficient and is very accurate.
(Yes)”, and the output terminal is given by the Address & final
Data which is sent to the display counter. VII. FUTURE SCOPE:

If the event fails to receive then it again send back to the Even though it provides the accurate readings, there is a
initial state where it then repeats the entire process and starts problem with the delay incured to get the data at the reciever
rechecking. At the end of the process the data is finalized to be side. At the reciever side, instead of a computer, it is better to
the right data, after which immediately the reset command is have a seperate device near the doctor so that it is possible to
activated which is the end task. So at the end the command reduce this delay also.
‘yes’ sets the reset value. And if it is a ‘no’ command then the
process set back to the program read mode.

ISSN: 2231-5381 http://www.ijettjournal.org Page 1421


International Journal of Engineering Trends and Technology (IJETT) - Volume4Issue5- May 2013

FLOW CHART REPRESENTATION

Figure 4: Flow chart representation

ISSN: 2231-5381 http://www.ijettjournal.org Page 1422


International Journal of Engineering Trends and Technology (IJETT) - Volume4Issue5- May 2013

ACKNOWLEDGMENT

The authors would like to thank everyone, whoever


remained a great source of help and inspirations in this humble
presentation. The authors would like to thank K.L. University
management for providing necessary facilities to carry out this
work.

REFERENCES

[1] “Development of Knitted Temperature Sensor


(KTS)” by Muhammad Dawood Husain or Locher,
T. Kirstein, and G. Troester,
[2] “Temperature Profile Estimation with Smart
Textiles”, in International Conference on Intelligent
textiles, Smart clothing, Well-being, and Design.
2005: Tampere, Finland.
[3] “Monitoring Body Temperature of Newborn Infants
at Neonatal Intensive Care Units Using Wearable
Sensors” by Wei Chen1, Sietse Dols1 Sidarto
Bambang Oetomo Loe Feijs1.
[4] “Heart rate sensor for integration into protective
equipment” by J. Witt (1), M. Schukar (1), K.
Krebber (1), Jaroslav Demuth (2), Ladislav Šašek
(2).
[5] “CPS Community Paediatrics Committee. Fever and
Temperature Taking”. Canadian Paediatric Society,
April 2008. http:// www.cps.ca /caringforkids /
when-sick / fever. Htm

BIBLIOGRAPHY:

[6] Microcontrollers Architecture, Programming,


Interfacing and System Design by Raj kamal
[7] Embedded Systems by Mazidi and Mazidi
[8] Embedded C by Michael. J. Pont.

WEB PAGES:

[9] www.wikipedia.com
[10] www.allaboutcircuits.com
[11] www.microchip.com
[12] www.howstuffworks.com
[13] www.zigbee.org.

ISSN: 2231-5381 http://www.ijettjournal.org Page 1423

You might also like