GRUNDFOS DATA BOOKLET

DMM
DOSING
Contents

General data Accessories


Performance range, 50 Hz Page 3 Overview Page 24
Performance range, 60 Hz Page 3 Installation kit Page 25
Type key Page 5 Cable and plug Page 26
Codes Page 5 Tubing Page 27
Foot valve Page 28
Injection valve Page 30
Functions Hot injection valve Page 32
Overview of functions Page 6 Multifunction valve Page 33
Capacity range Page 6 Flow indicator Page 34
Functional description, DMM-B Page 7 Pump connection Page 35
Functional description, DMM-AR Page 7 Rigid suction line Page 36
Control panel Page 8 Level control unit Page 38
Level control Page 9 Counter-pressure or relief valve Page 39
Alarm Page 9 Valve assembly Page 41
Functions of indicator lights and alarm output Page 9 Automatic venting valve Page 43
Wiring diagram, DMM-AR Page 10 Pulsation dampener Page 44
Priming aid Page 46
Tank Page 47
Construction Hand mixer Page 48
Electric mixer Page 49
Sectional drawing, DMM Page 11
Water meter Page 50
Construction Page 12
Material specification Page 12
Pumped liquids
Performance range List of pumped liquids Page 51
DMM Page 14

Technical data
Dimensions Page 15
DMM, 50 Hz Page 16
DMM, 60 Hz Page 17
Lubricant list Page 18

Pump selection
Standard range Page 19
Non-standard range Page 21

2
General data DMM

Performance range, 50 Hz
p
[bar]
DMM
11
50 Hz
10

TM02 8253 2203


0
1
0 2 5 10 20 50 100
99 260 390 640 990
Q [l/h]

Performance range, 60 Hz
p
[psi]
DMM
160 60 Hz

140

120

DMM-B
100
DMM-AR

80

60

40
DMM-B

20
TM02 8353 2203

0
0.5
1 1 2 4 6 10 20 40 60 100 150 200 300 400
Q [US GPH]

3
General data DMM

DMM-AR DMM-B

TM02 9075 1804


The DMM dosing pumps feature diaphragm dosing head
with suction and discharge ball valves.
The diaphragm stroke is generated by an external, fan-
cooled motor via a worm gear in an oil-lubricated
gearbox.
The capacity is set on the gearbox knob. DMM-AR also
offers setting via its control unit.
Thanks to its user-friendly control panel with soft-touch
buttons and display, DMM-AR also offers easy access to
a large number of pump operating modes and setting
possibilities.
Standard features of the DMM-AR pump are inputs for
pulse, analog 0/4-20 mA and dual-level control, a start/
stop input as well as an alarm output.
DMM-AR is fitted with power cable and plug.
See page 6 and onwards for further information.

4
General data DMM

Type key Codes


Example DMM 2 - 18 AR - PP / E / C - F - 1 1 1G F Example AR - PP / E / C - F - 1 1 3G F
Control variant
Type range
AR Standard + alarm relay
Maximum capacity [l/h] B Basic
Maximum pressure [bar] Dosing head material
PP Polypropylene
Code for control variant PV PVDF
Code for dosing head material SS Stainless steel 1.4571 (DMM)
Gasket material
Code for gasket material
E EPDM
Code for valve ball material V FKM
T PTFE
Code for control panel position
A Centellen C
Code for supply voltage H CSM
Code for valves Valve ball material
C Ceramic
Code for connection suction/discharge SS Stainless steel 1.4401
Code for mains plug G Glass
Control panel position
F Front-fitted
X No control panel
Supply voltage
0 Without motor
1 1 x 230 V, 50 Hz
2 1 x 120 V, 60 Hz
3 1 x 100-240 V, 50-60 Hz
4 3 x 230/400 V, 50 Hz
5 3 x 230/460 V, 60 Hz
6 1 x 120 V, 60 Hz
7 3 x 575 V, 60 Hz
8 1 x 100 V, 50/60 Hz
9 1 x 200 V, 50/60 Hz
A 1 x 100/200 V, 50 Hz
B 1 x 110 V, 50 Hz
Valves
1 Standard valve
2 Spring-loaded valve
Connection suction/discharge
Tubing 6/9mm
1 Tubing 4/6mm 
supplied with the pump
Tubing 6/9mm
2 Tubing 6/12 + 9/12mm
supplied with the pump
3 Tubing 4/6mm
4 Tubing 6/9mm
5 Tubing 6/12mm
6 Tubing 9/12mm
7 Hose clamp d.6mm
8 Hose clamp d.9mm
9 Hose clamp d.16mm
P Hose clamp d. 25mm
A Threaded Rp 1/4
B Threaded Rp 3/8
C Threaded Rp 1/2
D Threaded Rp 1
E Cementing d.10mm
F Cementing d.12mm
G Cementing d.16mm
H Cementing d.20mm
I Cementing d.25mm
J Cementing d.32mm
K Cementing d.40mm
L Flange DN 15
M Flange DN 25
Mains plug
F EU (Schuko)
B USA, Canada 120 V
C USA, Canada 240 V
G UK
I Australia, New Zealand, Taiwan
E Switzerland
J Japan
X No plug
 Hecker trademark

5
Functions Overview of functions

Overview of functions

TM01 8966 0900


TM01 8965 0900
DMM-AR DMM-B
Functional description, see page 7
Stroke length setting z z
Stroke frequency setting z
Control panel, see page 8
Display and one-touch buttons z
On/off button z
Green indicator light for operating indication z
Green indicator light for external control indication z
Red indicator light for fault indication z
Operating modes, see page 8
Manual control z z
Pulse control with pulse multiplication/division z
Analog 0/4-20 mA control z
Functions, see page 9
Level control z
Maximum permissible stroke frequency z
Inputs/outputs, see page 10
Input for pulse control z
Input for analog 0/4-20 mA control z
Input for dual-level control z
Input for external start/stop z
Alarm relay output z
Input for external on/off switch z

Capacity range

p
[bar]
DMM-AR DMM

12

DMM-B
10

8
290-8
210-10

260-10

160-10
6
440-5
4-10 8-10 15-10 23-10 48-10 72-10

4
TM01 8967 3100

110-5 155-4 390-6 640-5 990-4


2

0
0 4 8 15 23 48 72 110 160 210 290 390 640 990
Q [l/h]

6
Functions DMM

Functional description, DMM-B


On DMM-B, the capacity is set by setting the stroke
length on the gearbox knob. As shown in the figure
below, the stroke frequency is constant while only the

TM02 0134 1102


stroke length is adjusted.

Capacity
setting Discharge

100% Duration
Suction
Discharge
50% Duration
Suction

TM01 8963 0900


Discharge
10% Duration
Suction

Functional description, DMM-AR


On DMM-AR, the capacity can be set both by setting the
stroke length on the gearbox knob and the stroke fre-
quency on the control unit. The control unit controls the
stroke frequency by starting and stopping the motor ac-

TM02 0135 1102


cording to the set stroke frequency. The figure below
shows two examples:
1. The pump is running at 100% capacity at maximum
stroke length and stroke frequency.
2. The pump is running at 25% capacity at 50% stroke
length and 50% stroke frequency.

Capacity
setting

Discharge
100%
Duration

Suction
Discharge
25%
TM01 8964 0900

Duration

Suction

7
Functions Control panel

Control panel
Applies to DMM-AR
The control panel has two green indicator lights for operation and external control, one red indicator light for alarm, one
3-digit multifunctional display and four buttons for settings. The inputs for remote stop, low-level indication and external
control are located below the display.

Red indicator light for 


operating indication Navigation/settings
Green indicator light for external
control Start/stop of pump
Red indicator light for fault  Selection of operating
indication mode

Display

Connection for signal cable Connection for external


with M12 connector for external control
start/stop

Connection for signal cable with Screwed cable entry for


M12 connector for level sensor alarm output

TM01 4839 5001


Screwed cable entry for
supply cable Screwed cable entry for
motor supply cable

Start/stop of pump cation operation. In the case of division operation, the


number of received input pulses is shown. The indicator
The pump is started and stopped by means of the button
light Extern is on.
On/off. When the pump is stopped, the display shows
OFF. If the pump is stopped via an external start/stop
signal, the indicator light Extern will be on.

Operating modes
To select the operating mode, press the button Mode.
The display shows the designation of an operating mode
which can be changed using buttons and.

Manual control
The pump is dosing constantly according to the set
stroke length. Thanks to its control panel, DMM-AR also
offers setting of the stroke frequency.
INT appears in the display, and after releasing the button
Mode, the set stroke frequency is shown. The latter can
be modified using buttons  and. The value is
changed at an increasing speed with the button pressed.

Pulse control
Applies to DMM-AR
The pump is dosing according to an external pulse
signal, e.g. from a water meter.
The numbers of pump strokes per pulse (multiplication)
can be set between 1:1 and 1:64 and the numbers of
pulses per stroke (division) between 64:1 and 2:1.
After releasing the button Mode, the number of strokes
still to be carried out is indicated in the case of multipli-

8
Functions Control panel

Analog 0/4-20 mA control Alarm


Applies to DMM-AR
The pump allows to control the metering process. An
In the case of dosing with an analog signal, select a alarm is indicated visually in the display and forwarded
stroke length and an input signal: 0-20 mA or 4-20 mA. by the alarm relay.
The stroke frequency of the pump will be proportional to Low-level alarm signalling
the input signal, according to the curve shown below.
The indicator light Alarm flashes, and the alarm relay is
100 activated. The display shows E-L.
Low-level main alarm
Stroke frequency [%]

80
The indicator light Alarm is on, and the alarm relay is
60
A activated. The pump stops. The display shows E-L.
m
20
40 0- A Internal fault
m
2 0
4- The pump carries out a self-check which switches off the
20
pump, if no stroke has been carried out two seconds
TM01 8969 0900

0
after start-up of motor (e.g. in the case of excessively
high backpressure) or if the stroke sensor does not work
0 4 8 12 16 20
Input signal [mA] (display E-2). In addition, it is possible to connect a
diaphragm failure sensor (display E-H) and a dosing
If a maximum permissible stroke frequency has been monitor (display E-F)
set, 100% (20mA) will correspond to the set value. Alarm relay
It is possible to choose between a 0....20 mA or 4...20 mA If the buttons Mode and  are pressed while applying
standard signal (display 0.20 or 4.20). After releasing the voltage (display REO), the relay is currentless in the case
button Mode, the stroke frequency corresponding to the of fault and OFF. When the buttons Mode and  are
current appears in the display. The indicator light Extern pressed, the relay is activated in the case of fault (display
is on. If the current exceeds 20 mA (display OVL) or RET).
decreases below 4 mA in the range of 4...20 mA (display
E-I), the indicator light Alarm lights up, the alarm relay is Functions of indicator lights and
activated and the pump stops.
alarm output
Level control Condition
Green Red Alarm
indicator light indicator light output
Applies to DMM-AR
The pump can be fitted with a level control unit for Pump running On Off
1 2 3
monitoring of the chemical level in the tank. NC NO C

The pump can react to two level signals. The following


table shows the pump reactions to the sensor signals. Set to stop Flashing Off
1 2 3
Level sensors Pump reaction NC NO C

• Red indicator light is on.


Upper sensor activated • Pump running. Pump fault Off On
• Alarm relay activated. 1 2 3
NC NO C
• Red indicator light is on.
Lower sensor activated • Pump stopped.
• Alarm relay activated. Supply failure Off Off
1 2 3
NC NO C
Maximum permissible stroke frequency
Pump running, 
Applies to DMM-AR low chemical On On
level 1 2 3
NC NO C
The maximum stroke frequency of the pump can be
limited, for instance to adapt the pump operation to an
analog 0/4-20 mA signal without reducing the stroke Empty tank Off On
1 2 3
length. NC NO C

Keep the buttons Mode and On/off pressed while


Analog signal 
applying voltage and set the maximum number of pump < 3 mA
Off On
1 2 3
strokes using the buttons and. After releasing the NC NO C
button Mode, normal operation starts. Requires connection to level sensors.

9
Functions DMM

Wiring diagram, DMM-AR


See page 16 for input/output data.

Alarm relay

(NC) Brown
(NO) Black
2
Start/stop of pump (Com) Blue
1

2 3 4 1 3 4

Level/start/stop cable Control cable


Product no.: Product no.:
2 m cable: 96440450 2 m cable: 96440447
5 m cable: 96440451 5 m cable: 96440448

2 1

3 2

1 3
4
Empty 4
Low level tank
TM02 0677 2203

Control input
Number 1 2 3 4
Colour Brown White Blue Black
Function Not used Not used (+) Pulse input, (+) 4-20 mA input (-) Pulse input, (-) 4-20 mA input

Level input
Number 1 2 3 4
Colour Brown White Blue Black
Function (-) Low level (-) Empty tank/pump stop (+) Low level/empty tank ( ) Earth (optional)

Start/stop of pump (closed contact = pump stopped)


Number 1 2 3 4
Colour Brown White Blue Black
Function Start/stop of pump Not used Not used

10
Construction DMM

Sectional drawing, DMM


DMM 4 to DMM 155

Standard Spring-loaded
valve valve

12 12
13 20
3
21 14 19

10 21
10

8
15 18
2
16
17

TM01 9580 1003


Tubing  Threaded
connection connection

DMM 160 to DMM 390

Spring-loaded Standard
connection valve

12 12 1
11 11
20 13
3
14 21 19
21 10
10
8
18
2

Threaded
connection
TM01 8970 1003

11
Construction DMM

Sectional drawing, DMM


DMM 440 to DMM 990

1
8
2

4
20
14
22
3
4
6
4
5

TM01 8971 1003


Construction Material specification
The Grundfos DMM pumps are mechanical diaphragm Pos. Description Material options
dosing pumps. The pumps are driven by an external fan- 1 Motor -
cooled motor, connected to a single-stage worm reduc- Textile-reinforced EPDM, 
2 Diaphragm
PTFE-coated
tion gear. The strokes are generated by an eccentric
3 Valve complete -
which moves the diaphragm by means of a spring-
4 O-ring EPDM/FKM
loaded plunger. The injection stroke is activated by the
5 Valve casing PP/Stainless steel 1.4571
eccentric and the suction stroke by the spring return.
6 Valve seat PP/Stainless steel 1.4571
The pumps are designed for capacities between 4 and 8 Dosing head PP/Stainless steel 1.4571
990 l/h and a maximum pressure of 10 bar. The pumps 10 Valve gasket CSM/FKM/Centellen C1/PTFE
are fitted with a separation chamber which, in the event 11 Valve gasket CSM/FKM/Centellen C1/PTFE
of a diaphragm failure, prevents the pumped liquid from
12 Valve gasket CSM/FKM/Centellen C1/PTFE
flooding the pump unit or other system components.
13 Valve, double ball -
14 Valve, spring-loaded -
15 Union nut PP/Stainless steel 1.4571
16 Clamping ring PP
17 Union nut, tubing PP
Union nut, threaded 
18 PP/Stainless steel 1.4571
connection
19 Control unit (DMM-AR only) GKAlSi12/PPO
20 Spring Hastelloy
Ceramic/glass/PTFE/
21 Ball
Stainless steel 1.4401
22 Valve disk PVDF/Stainless steel1.4571
1 Centellen C is a Hecker trademark.

12
Performance range DMM

DMM 4-101 DMM 8-101


ml/stroke l/h ml/stroke l/h

TM01 4900 1099

TM01 4901 1099


Stroke length setting Stroke length setting

DMM 15-101 DMM 23-10


ml/stroke l/h ml/stroke l/h
TM01 4902 1099

TM01 4903 1099


Stroke length setting Stroke length setting

DMM 48-101 DMM 72-10


ml/stroke l/h ml/stroke l/h

TM01 4905 1099


TM01 4904 1099

Stroke length setting Stroke length setting

DMM 110-51 DMM 155-4


ml/stroke l/h ml/stroke l/h
TM01 4906 1099

TM01 4907 1099

Stroke length setting Stroke length setting

13
Performance range DMM

DMM 160-101 DMM 210-101


ml/stroke l/h ml/stroke l/h

TM01 4909 1099


TM01 4908 1099
Stroke length setting Stroke length setting

DMM 260-102 DMM 290-81


ml/stroke l/h ml/stroke l/h

TM01 4911 1099


TM01 4910 4701

Stroke length setting Stroke length setting

DMM 390-62 DMM 440-5 (DMM-B only)1


ml/stroke l/h l/h
TM01 4912 1099

TM01 2191 1498

Stroke length setting Stroke length setting

DMM 640-5 (DMM-B only)1 DMM 990-4 (DMM-B only)1


l/h l/h
TM01 2190 1498

TM01 2192 1498

Stroke length setting Stroke length setting

1 In 60 Hz operation, the flow rate in l/h will be 20% higher than


shown in the curves at the same stroke length and pressure.
2 Not suitable for 60 Hz operation.

14
Technical data DMM

DMM 4 to DMM 155 DMM 160 to DMM 390 DMM 440 to DMM 990

TM01 9170 1300Dimensions


TM01 4683 0699
TM01 4681 0699

Dimensions [mm]
Pump type
A B C D
DMM 4 108 95 212 372
DMM 8 108 95 212 372
DMM 15 108 95 212 372
DMM 23 108 95 212 372
DMM 48 147 103 224 372
DMM 72 147 103 224 372
DMM 110 243 117 259 372
DMM 155 243 117 259 372
DMM 160 278 148 317 486
DMM 210 278 148 317 486
DMM 260 278 148 317 486
DMM 290 318 153 320 486
DMM 390 318 153 320 486
DMM 440 265 225 425 530
DMM 640 265 225 425 530
DMM 990 265 225 425 530

15
Technical data DMM

DMM, 50 Hz
DMM 4 8 15 23 48 72 110 155 160 210 260 290 390 440 640 990
Mechanical data
Maximum capacity at  [l/h] 4 7.5 15 23 48 72 107 160 156 208 263 292 393 440 640 990
maximum pressure [ml/stroke] 2.6 2.6 2.6 2.6 8.5 8.5 19 19 36.5 36.5 36.5 51.2 54.5 165 165 165
Maximum pressure [bar] 10 10 10 10 10 10 5 4 10 10 10 8 6 5 5 4
Diaphragm diameter [mm] 52 52 52 52 64 64 90 90 120 120 120 150 150 185 185 185
Maximum stroke frequency [stroke/min.] 26 48 95 142 95 142 95 142 71 95 120 95 120 47 70 101
Maximum suction lift during
[m] 5 5 3.8 2.5 4 3.3 2.5 2 3 2.5 2 2.5 2 3 3 3
operation
Maximum ambient 
[°C] 40
temperature
Maximum liquid temperature [°C] 50
Accuracy of repeatability ±2%
Weight (plastic pump head) [kg] 8.2 8.2 8.2 8.2 8.4 8.2 10 10 17 17 17 18 18 38 38 38
Weight 
[kg] 11 11 11 11 12 12 20 20 22 22 22 26 26 48 48 48
(stainless steel pump head)
Input/output data (DMM-AR)
Voltage to level sensor input [VDC] 5 -
Maximum loop resistance in
[:] 350 -
level signal circuit
Voltage to pulse transmitter [VDC] 5 -
Maximum loop resistance in
[:] 350 -
pulse circuit
Internal impedance in
[:] 250 -
0/4-20 mA input
Maximum voltage, alarm relay 
[V] 250 -
output
Maximum load of alarm relay
[A] 2 -
output
Standard motor data (DMM-B)
K21R71G4
AF63/4A-7 AF63/4C-7
Standard motor type EB20RW71A4TS140 AF 80/4 B-11
ABF63/4B-7 RQ ABF63/4B-7 RQ
K21R80K4TPM
1370
1360 1370
Speed [min-1] 1360 1300
1400 1400
1390
3 x 400
1 x 230 3 x 400
Rated voltage [V] 1 x 230 3 x 400
1 x 230 1 x 230
3 x 400
1.06
0.7 0.9
Rated current [A] 2.3 2
0.7 1.15
1.25
0.37
Power P2 0.05 0.25
[kW] 0.25 0.75
0.05 0.12
0.55
Frequency [Hz] 50
Enclosure class IP 55
Insulation class F
Standard motor data (DMM-AR)
K21R71G4
AF63/4C-7
Standard motor type ABF63/4B-7 RQ EB20RW71A4TS140 AF 80/4 B-11
ABF63/4B-7 RQ
AF 80/4 A-11
1370
1370
Speed [min-1] 1360
1300
1400 1400
1390
3 x 400
3 x 400
Rated voltage [V] 1 x 230 1 x 230 3 x 400
1 x 230
3 x 400
1.06
0.9
Rated current [A] 0.7 2.3 2
1.15
1.25
0.37
Power P2 0.25
[kW] 0.05 0.25 0.75
0.12
0.55
Frequency [Hz] 50
Enclosure class IP 55
Insulation class F
Approvals: CE, CSA
Sound pressure level: The sound pressure level of DMM 4-48 is lower than 70 dB(A), and that of DMM 72-990 is lower than 75 dB(A).
0.12 kW is for DMM 48 (single-phase).

16
Technical data DMM

DMM, 60 Hz
DMM 4 8 15 23 48 72 110 155 160 210 290 440 640 990

Mechanical data
Maximum capacity at  [l/h] 4.8 9 18 23 58 72 128 160 187 250 350 528 768 1188
maximum pressure [ml/stroke] 2.6 2.6 2.6 2.6 8.5 8.5 19 19 36.5 36.5 51.2 165 165 165
Maximum pressure [bar] 10 10 10 10 10 10 5 4 10 10 8 5 5 4
Diaphragm diameter [mm] 52 52 52 52 64 64 90 90 120 120 150 185 185 185
Maximum stroke frequency [stroke/min.] 26 48 95 142 95 142 95 142 71 95 95 47 70 101
Maximum suction lift during
[m] 5 5 3.8 2.5 4 3.3 2.5 2 3 2.5 2.5 3 3 3
operation
Maximum ambient temperature [°C] 40
Maximum liquid temperature [°C] 50
Accuracy of repeatability ±2%
Weight (plastic pump head) [kg] 8.2 8.2 8.2 8.2 8.4 8.2 10 10 17 17 18 38 38 38
Weight 
[kg] 11 11 11 11 12 12 20 20 22 22 26 48 48 48
(stainless steel pump head)
Input/output data (DMM-AR)
Voltage to level sensor input [VDC] 5 -
Maximum loop resistance in level
[:] 350 -
signal circuit
Voltage to pulse transmitter [VDC] 5 -
Maximum loop resistance in pulse
[:] 350 -
circuit
Internal impedance in
[:] 250 -
0/4-20 mA input
Maximum voltage, alarm relay 
[V] 250 -
output
Maximum load of alarm relay
[A] 2 -
output

DMM 4 8 15 26 48 76 110 156 160 210 260 290 390 440 640 990
Standard motor data (DMM-B)
KPR 63 K4 KPR 63 K4 KPER 71 G4 KPER 80 G4
Standard motor type
ABF63/4B-7RQ ABF63/4B-7RQ EB20 RW71 K4 TS140 EB20 RW80 G4
1710 1710 1710 1710
Speed [min-1]
1650 1650 1680 1680
3 x 230/460
Rated voltage [V]
1 x 120
1.18/0.72 1.18/0.72 1.5/0.9 3.15/1.9
Rated current [A]
2.2 2.2 5.1 12

Power P2 0.25 0.25 0.37 0.75


[kW]
0.12 0.12 0.25 0.75
Frequency [Hz] 60
Enclosure class IP 55
Insulation class F
Standard motor data (DMM-AR)
Standard motor type ABF63/4B-7RQ ABF63/4B-7RQ EB20 RW71 K4 TS140
Speed [min-1] 1650 1650 1680
Rated voltage [V] 1 x 120
Rated current [A] 2.2 2.2 5.1
Power P2 [kW] 0.12 0.12 0.25
Frequency [Hz] 60
Enclosure class IP 55
Insulation class F
Approvals CE, CSA
Sound pressure level: The sound pressure level of DMM 4-48 is lower than 70 dB(A), and that of DMM 72-990 is lower than 75 dB(A).

17
Technical data DMM

Lubricant list
Lubrication Quantity of oil
Pump type Lubricant oil Oil change Oil check Recommended brands
points single-/double gear [ml]
Aral: Vitam UF100
250 / 500 BP: Energol EM100
Gear oil, viscosity First time after ap-
DMM  250 / 500 Esso: Esstic 100
class ISO-VG 100 to prox. 500 hours of
50-990 l/h Gear 250 / 500 Twice a year
DIN 51519 (SAE 80 to operation; then after Fuchs: Renolin 104
model B 700 / 900
DIN 51512) 5000 hours or 2 years
700 / 900 Mobil: Rubrex 750
Shell: Vitrea 100
Aral: Degol BG 460
Energol
BP:
GR-XP 460
Gear oil, viscosity First time after ap- Esso: Spartan EP 460
DMM 
class ISO-VG 460 to 250 / - prox. 500 hours of
4-390 l/h Gear Twice a year Renep Comp.
DIN 51519 (SAE 140 700 / - operation; then after Fuchs:
model AR 110-VG460
to DIN 51512) 5000 hours or 2 years
Mobilgear 634
Mobil:
Comp. FF
Shell: Omala Oel 460

Motor selection for frequency converter operation


Motors for frequency converter operation are fitted with
a PTC sensor.
The frequency converter should be one size bigger to
deliver the required starting current.
Standard motor Motor for frequency converter operation
Pump type
Part no. Power [W] Part no. Power [W]
DMM 4-48 l/h 96508465 50 96508531 250
DMM 72-155 l/h 96508467 250 96508532 250
DMM 160-390 l/h 96508468 370 96508533 550
DMM 440-640 l/h 96508469 750 96508534 750
DMM 990 l/h 96508530 750 96508535 750

18
Pump selection DMM

Standard range
Valves, DMM 4 to DMM 390: Double-ball on suction and discharge side.
Valves, DMM 440 to DMM 990: Spring-loaded valve disk on suction and discharge side.
Control Materials 2
Max. Max. Connection
capacity pressure
variant Voltage 1 Type name
Product
[l/h] [bar]
see 50 Hz Pump head Gaskets Valve balls 3 number
page 6
PP EPDM Glass 6/9 DMM 4-10 AR-PP/E/G-F-1144F 96429431
AR 1 x 230 V Stainl. steel Stainl. steel
PTFE Rp 1/4 DMM 4-10 AR-SS/T/SS-F-11AAF 96441413
1.4571 1.4401
4 10
PP EPDM Glass 6/9 DMM 4-10 B-PP/E/G-X-4144X 96429418
B 3 x 400 V Stainl. steel Stainl. steel
PTFE Rp 1/4 DMM 4-10 B-SS/T/SS-X-41AAX 96441414
1.4571 1.4401
PP EPDM Glass 6/9 DMM 8-10 AR-PP/E/G-F-1144F 96429432
AR 1 x 230 V Stainl. steel Stainl. steel
PTFE Rp 1/4 DMM 8-10 AR-SS/T/SS-F-11AAF 96 441421
1.4571 1.4401
8 10
PP EPDM Glass 6/9 DMM 8-10 B-PP/E/G-4144X 96429419
B 3 x 400 V Stainl. steel Stainl. steel
PTFE Rp 1/4 DMM 8-10 B-SS/T/SS-X-41AAX 96441422
1.4571 1.4401
PP EPDM Glass 6/9 DMM 15-10 AR-PP/E/G-F-1144F 96429433
AR 1 x 230 V Stainl. steel Stainl. steel
PTFE Rp 1/4 DMM 15-10 AR-SS/T/SS-F-11AAF 96443240
1.4571 1.4401
15 10
PP EPDM Glass 6/9 DMM 15-10 B-PP/E/G-X-4144X 96429420
B 3 x 400 V Stainl. steel Stainl. steel
PTFE Rp 1/4 DMM 15-10 B-SS/T/SS-X-41AAX 96443349
1.4571 1.4401
PP EPDM Glass 6/9 DMM 23-10 AR-PP/E/G-F-1144F 96429434
AR 1 x 230 V Stainl. steel Stainl. steel
PTFE Rp 1/4 DMM 23-10 AR-SS/T/SS-F-11AAF 96441405
1.4571 1.4401
23 10
PP EPDM Glass 6/9 DMM 23-10 B-PP/E/G-X-4144X 96429421
B 3 x 400 V Stainl. steel Stainl. steel
PTFE Rp 1/4 DMM 23-10 B-SS/T/SS-X-41AAX 96441406
1.4571 1.4401
PP CSM Ceramic 6/9 DMM 48-10 AR-PP/H/C-F-1144F 96429435
AR 1 x 230 V Stainl. steel Asbestos- Stainl. steel
Rp 1/4 DMM 48-10 AR-SS/A/SS-F-11AAF 96441416
1.4571 free 1.4401
48 10
PP CSM Ceramic 6/9 DMM 48-10 B-PP/H/C-X-4144X 96429422
B 3 x 400 V Stainl. steel Asbestos- Stainl. steel
Rp 1/4 DMM 48-10 B-SS/A/SS-X-41AAX 96441417
1.4571 free 1.4401
PP CSM Ceramic 6/9 DMM 72-10 AR-PP/H/C-F-1144F 96429436
AR 1 x 230 V Stainl. steel Asbestos- Stainl. steel
Rp 1/4 DMM 72-10 AR-SS/A/SS-F-11AAF 96441419
1.4571 free 1.4401
72 10
PP CSM Ceramic 6/9 DMM 72-10 B-PP/H/C-X-4144X 96429423
B 3 x 400 V Stainl. steel Asbestos- Stainl. steel
Rp 1/4 DMM 72-10 B-SS/A/SS-X-41AAX 96441420
1.4571 free 1.4401
PP CSM Glass Rp 1/2 DMM 110-5 AR-PP/H/G-F-11CCF 96429 37
AR 1 x 230 V Stainl. steel Asbestos- Stainl. steel
Rp 1/2 DMM 110-5 AR-SS/A/SS-F-11CCF 96441397
1.4571 free 1.4401
110 5
PP CSM Glass Rp 1/2 DMM 110-5 B-PP/H/G-X-41CCX 96429424
B 3 x 400 V Stainl. steel Asbestos- Stainl. steel
Rp 1/2 DMM 110-5 B-SS/A/SS-X-41CCX 96441398
1.4571 free 1.4401
PP CSM Glass Rp 1/2 DMM 155-4 AR-PP/H/G-F-11CCF 96429438
AR 1 x 230 V Stainl. steel Asbestos- Stainl. steel
Rp 1/2 DMM 155-4 AR-SS/A/SS-F-11CCF 96441399
1.4571 free 1.4401
155 4
PP CSM Glass Rp 1/2 DMM 155-4 B-PP/H/G-X-41CCX 96429425
B 3 x 400 V Stainl. steel Asbestos- Stainl. steel
Rp 1/2 DMM 155-4 B-SS/A/SS-X-41CCX 96441400
1.4571 free 1.4401
PP CSM Glass Rp 1/2 DMM 160-10 AR-PP/H/G-F-11CCF 96429439
AR 1 x 230 V Stainl. steel Asbestos- Stainl. steel
Rp 1/2 DMM 160-10 AR-SS/A/SS-F-11CCF 96441401
1.4571 free 1.4401
160 10
PP CSM Glass Rp 1/2 DMM 160-10 B-PP/H/G-X-41CCX 96429426
B 3 x 400 V Stainl. steel Asbestos- Stainl. steel
Rp 1/2 DMM 160-10 B-SS/A/SS-X-41CCX 96441402
1.4571 free 1.4401
PP CSM Glass Rp 1/2 DMM 210-10 AR-PP/H/G-F-11CCF 96429440
AR 1 x 230 V Stainl. steel Asbestos- Stainl. steel
Rp 1/2 DMM 210-10 AR-SS/A/SS-F-11CCF 96441403
1.4571 free 1.4401
210 10
PP CSM Glass Rp 1/2 DMM 210-10 B-PP/H/G-X-41CCX 96429427
B 3 x 400 V Stainl. steel Asbestos- Stainl. steel
Rp 1/2 DMM 210-10 B-SS/A/SS-X-41CCX 96441404
1.4571 free 1.4401

19
Pump selection DMM

Control Materials 2
Max. Max.
capacity pressure
variant Voltage 1 Connection
Type name
Product
[l/h] [bar]
see 50 Hz Pump head Gaskets Valve balls 3 number
page 6
PP CSM Glass Rp 1/2 DMM 260-10 AR-PP/H/G-F-11CCF 96429441
AR 1 x 230 V Stainl. steel Asbestos- Stainl. steel
Rp 1/2 DMM 260-10 AR-SS/A/SS-F-11CCF 96441407
1.4571 free 1.4401
260 10
PP CSM Glass Rp 1/2 DMM 260-10 B-PP/H/G-X-41CCX 96429428
B 3 x 400 V Stainl. steel Asbestos- Stainl. steel
Rp 1/2 DMM 260-10 B-SS/A/SS-X-41CCX 96441408
1.4571 free 1.4401
PP CSM Glass Rp 1/2 DMM 290-8 AR-PP/H/G-F-11CCF 96429442
AR 1 x 230 V Stainl. steel Asbestos- Stainl. steel
Rp 1/2 DMM 290-8 AR-SS/A/SS-F-11CCF 96441409
1.4571 free 1.4401
290 8
PP CSM Glass Rp 1/2 DMM 290-8 B-PP/H/G-X-41CCX 96429429
B 3 x 400 V Stainl. steel Asbestos- Stainl. steel
Rp 1/2 DMM 290-8 B-SS/A/SS-X-41CCX 96441410
1.4571 free 1.4401
PP CSM Glass Rp 1/2 DMM 390-6 AR-PP/H/G-F-11CCF 96429443
AR 1 x 230 V Stainl. steel Asbestos- Stainl. steel
Rp 1/2 DMM 390-6 AR-SS/A/SS-F-11CCF 96441411
1.4571 free 1.4401
390 6
PP CSM Glass Rp 1/2 DMM 390-6 B-PP/H/G-X-41CCX 96429430
B 3 x 400 V Stainl. steel Asbestos- Stainl. steel
Rp 1/2 DMM 390-6 B-SS/A/SS-X-41CCX 96441412
1.4571 free 1.4401
PP CSM PVDF Rp 1 DMM 440-5 B-PP/H/PV-X-42DDX 96417058
440 5 B 3 x 400 V Stainl. steel Stainl. steel
CSM Rp 1 DMM 440-5 B-SS/H/SS-X-42DDX 96441415
1.4571 1.4571
PP CSM PVDF Rp 1 DMM 640-5 B-PP/H/PV-X-42DDX 96417059
640 5 B 3 x 400 V Stainl. steel Stainl. steel
CSM Rp 1 DMM 640-5 B-SS/H/SS-X-42DDX 96441418
1.4571 1.4571
PP CSM PVDF Rp 1 DMM 990-5 B-PP/H/PV-X-42DDX 96417060
990 4 B 3 x 400 V Stainl. steel Stainl. steel
CSM Rp 1 DMM 990-5 B-SS/H/SS-X-42DDX 96441425
1.4571 1.4571

1 See page 16 for further motor data.


2 See list of pumped liquids on page 51.
3 6/9 are compression fittings for 6 mm inner and 9 mm outer tubing diameters. 
Rp 1/4, Rp 1/2 and Rp 1 connections have inner thread for pipe connection.

20
Pump selection DMM

Non-standard range
Example in bold: DMM 160-10 AR-PP/H/G-F-12GGF
Maximum 
capacity Control Materials of pump head, Control panel Suction/discharge
Motor voltage Valves Mains plug
and variant gaskets and valve balls position connection
pressure
4 = Tubing 6/9
5 = Tubing 6/12
T = Tubing 0.125’’/0.25’’
R =Tubing 0.25’’/0.375’’
7 = Hose clamp d.6
8 = Hose clamp d.9
9 = Hose clamp d.16
1= P = Hose clamp d. 25
PP = Polypropylene 1 x 230 V, 50 Hz A = Threaded Rp 1/4
B = USA +
SS = Stainl. steel 1.4571 2 = B = Threaded Rp 3/8
CAN 120 V
E = EPDM 1 x 120 V, 60 Hz C = Threaded Rp 1/2
E = CH
V = FKM 4= D = Threaded Rp 1
F = Front-fitted 1 = Standard F = EU
[l/h] - [bar] See page 6 H = CSM 3 x 230/400 V, V = Threaded NPT1/4’’
X = No panel 2 = Spring-loaded (Schuko)
50 Hz Y = Threaded NPT 3/8’’ 
A = Centellen C6 G = DK
5= X = Threaded NPT 1/2’’
T = PTFE I = AU
3 x 230/460 V, Z = Threaded NPT 1’’
G = Glass X = No plug
60 Hz E = Cementing d.10
7 = 3 x 575 V, 60 Hz F = Cementing d.12
G = Cementing d.16
H = Cementing d.20
I = Cementing d.25
J = Cementing d.32
K = Cementing d.40
L = Flange DN 15
M = Flange DN 25
DMM
PP/E/G 2
4
PP/V/G 2 5
PP/H/G1 4
7
5 F
PP/E/SS2 T
7
1 R B
PP/V/SS2 1 A
-F- 2 A G
2
PP/H/G1 6 V
E I
PP/T/G3 F E
AR- E
PV/T/C1 F G1
PV/T/T G1
T/T/T
SS/V/SS3 F
1 A B
SS/T/SS3 1 A
4-104 -F- 2 V G
SS/E/SS3 2 7
6 7 I
8-104 SS/A/SS1 E
15-104
23-10 PP/E/G 2
4
48-104 PP/V/G 2 5
PP/H/G1 4
72-10 1 7
5
PP/E/SS2 2 T
7
PP/V/SS2 4 1 R
-X- A X
5 2 A
PP/H/G1 V
E
6 F
PP/T/G3 7 E
B- PV/T/C1 F G 1
PV/T/T G 1
T/T/T
1
SS/V/SS3 2
A
SS/T/SS3 4 1 A
-X- V X
SS/E/SS3 5 2
7
7
6
SS/A/SS1
7

21
Pump selection DMM

Maximum 
capacity Control Materials of pump head, Control panel Suction/discharge
Motor voltage Valves Mains plug
and variant gaskets and valve balls position connection
pressure
8
PP/H/G 9 8
PP/V/G B 9 F
PP/H/SS 1 C B B
1
PP/V/SS -F- 2 Y C G
6
2 X G I
PV/T/G
PV/T/T G H E
T/T/T H I
-AR-
I
8
9 8 F
110-54 1 B 9 B
1
155-4 SS/A/SS -F- 2 C B G
2
6 Y C I
160- X L E
104 L
210-104 8
PP/H/G
260-105 PP/V/G 1
9 8
290-84 B 9
PP/H/SS 2
C B
390-65 PP/V/SS
-X-
4 1
Y C X
PP/T/G 5 2
X G
PP/T/T 6
G H
T/T/T 7
H I
B- I
8
1
9 8
2
B 9
4 1
SS/A/SS -X- C B X
5 2
Y C
6
X L
7
L
PP/H/PV D
D
440-54 PP/V/PV Z
4 P
PV/T/PV P
640-54 B-
T/T/PV
-X- 5 2
J
J X
990-44 7 K
SS/V/SS K
M
SS/H/SS M
1 Only available for DMM 48 and DMM 72.
2 DMM 48 and DMM 72 have ceramic valve balls.
3 Not available for DMM 48 and DMM 72.
4 In 60 Hz operation, the performance will be 20 % higher.
5 Not available for 60 Hz.
6 Hecker trademark.
7 DMM 440 to DMM 990 have valve disks instead of valve balls.
8 Up to 23 l/h.

22
Pump selection DMM

23
Accessories Overview

Overview

Water meter 
See page 50

Counter-pressure and Injection valve


relief/isolating valve See page 30
See page 39

Pulsation dampener
Automatic vent valve See page 44
See page 43

Multifunction valve
See page 33 Pressure gauge
See page 45
Flow indicator
See page 34

Connector for pulsation dampener


See page 45

Pump connections
See page 35

Priming aid
See page 46

Tubing
See page 27
Cable and plug
See page 26

Installation kit
See page 25 Dosing monitor
See page 34

Tank
See pages
47-48

Rigid suction line


with level sensors Hand mixer
Rigid suction line See page 36 See page 48
See page 36
Foot valve Level control unit
See page 28 See page 38 Electric mixer
See page 49
TM02 9030 1504

24
Accessories Installation kit

Installation kit
The installation kit includes:
• foot non-return valve with strainer and weight
• injection non-return valve, spring-loaded
6 metres
• 6 m PE discharge tubing
• 2 m PVC suction tubing
• 2 m PVC vent tubing.

2 metres

TM01 8956 0900

TM02 9031 1504


Max. flow rate Valve materials Inner/outer tubing diameters
Size Product number
[l/h] Housing Gasket Ball Suction Discharge Vent
4/6 4/6 4/6 96457109
PP EPDM Ceramic 6/9 6/9 4/6 96434858
0.17"/1/4" 0.17"/1/4" 96480670
1/4"/3/8" 1/4"/3/8" 96479881
6/9 6/9 4/6 96446723
PP FKM Ceramic 4/6 4/6 4/6 96457110
4-12 DN 4
0.17"/1/4" 0.17"/1/4" 96480674
1/4"/3/8" 1/4"/3/8" 96479898
6/9 6/9 4/6 96434859
4/6 4/6 4/6 96457111
PVDF FKM Ceramic
0.17"/1/4" 0.17"/1/4" 96480675
1/4"/3/8" 1/4"/3/8" 96479899
9/12 9/12 4/6 96440445
PP EPDM Ceramic
3/8"/1/2" 3/8"/1/2" 96479947
9/12 9/12 4/6 96446724
15-48 DN 8 PP FKM Ceramic
3/8"/1/2" 3/8"/1/2" 96479949
9/12 9/12 4/6 96440446
PVDF FKM Ceramic
3/8"/1/2" 3/8"/1/2" 96479948

25
Accessories Cable and plug

Cable and plug


Cable and plug for connection of pump to external
control devices, such as process controllers, flow meters,
start/stop contacts, and level sensors.
Grundfos level control units are factory-fitted with cable
and plug connection for Grundfos dosing pumps.
The cables and plugs fit all dosing pumps DMM-AR.
Cable material: PUR (0.34 mm2).

TM01 8955 0900


Plug type: M12.

Cable length
Signal Number of poles Type Product number
[m]
2 96440447
Pulse, 0/4-20 mA, start/stop 5
5 96440448
Cable moulded with plug
2 96440450
Dual-level or stop signal 4
5 96440451
Pulse, 0/4-20 mA, start/stop 5 - 96440449
Plug with terminals without cable
Dual-level 4 - 96440452
- 4 Extension cable 2 96483235

26
Accessories Tubing

Tubing
Tubing in various materials, sizes and lengths.

TM01 8958 0900


Inner/outer Maximum pressure Length
Material Product number
diameters [mm] [bar] [m]
16 10 96441188
PE
16 50 96441190
0.5 10 96441189
4/6 PVC
0.5 50 96441191
20 10 96441351
ETFE
20 50 96441352
13 10 96441192
PE
13 50 96441195
0.5 10 96441193
6/9 PVC
0.5 50 96441194
20 10 96441353
ETFE
20 50 96441354
13 10 96441196
PE
13 50 96441198
0.5 2 96535083
9/12 PVC 0.5 10 96441197
0,5 50 96441199
20 10 96441355
ETFE
20 50 96441356
12/19 PVC, textile-reinforced 15 10 96534489
15/20 PVC 0,5 2 96535081
16/24 14 10 96441200
25/34 10 10 96441201
25/34 PVC, textile-reinforced 10 5 96535070
32/41 9 5 96535077
32/41 9 10 96535079

27
Accessories Foot valve

Foot valve
Foot valve complete with non-return valve, strainer,
weight and tube or pipe connection.

TM01 9285 1600


Dimensions
DN 4, DN 8 DN 6, DN 10, DN 15, DN 20, DN 25
Tubing/non-return valve Hose clamp Pipe cementing
TM01 9276 1600 - TM02 6433

Non-return
valve
TM01 2201 1600

TM01 9277 1600


Materials Connection Dimensions
Max. flow Inner/outer Product
d ø L Valve kit
rate [l/h] Size Housing Gasket Ball Type tubing or pipe number
[mm] [mm]
diameters
4/6 - 36 72 96440526
6/9 - 36 72 96440527
PP EPDM Ceramic Tubing 96499704
0.17"/1/4" - 36 72 96480503
1/4"/3/8" - 36 72 96479782
4/6 - 36 72 96446860
6/9 - 36 72 96446861
15 DN 4 PP FKM Ceramic Tubing 96499705
0.17"/1/4" - 36 72 96480589
1/4"/3/8" - 36 72 96479784
4/6 - 36 72 96440529
6/9 - 36 72 96440530
PV FKM Ceramic Tubing 96499708
0.17"/1/4" - 36 72 96480620
1/4"/3/8" - 36 72 96479787
6/9 - 36 72 96441841
9/12 - 36 72 96440528
PP EPDM Ceramic Tubing 96499706
1/4"/3/8" - 36 72 96480621
3/8"/1/2" - 36 72 96479798
6/9 - 36 72 96446865
9/12 - 36 72 96446864
72 DN 8 PP FKM Ceramic Tubing 96499707
1/4"/3/8" - 36 72 96480622
3/8"/1/2" - 36 72 96480623
6/9 - 36 72 96441842
9/12 - 36 72 96440531
PV FKM Ceramic Tubing 96499709
1/4"/3/8" - 36 72 96480624
3/8"/1/2" - 36 72 96479801

28
Accessories Foot valve

Materials Connection Dimensions


Max. flow Inner/outer Product
d ø L Valve kit
rate [l/h] Size Housing Gasket Ball Type tubing or pipe number
[mm] [mm]
diameters
PVC - Glass Pipe cementing -/12 12 32 37 96440535
Hose clamp 6/- 7 32 74 96446862
48 DN 6 Stainl.
CSM Stainl. steel -/Rp 1/4 Rp 1/4 32 37 96446863
steel Threaded
-/1/4" NPT 1/4" NPT 32 37 96479794
PP EPDM 22/26 39 115 96527112
19/27
PP Ceramic Hose clamp 22/26 39 115 96527113
FKM 25/34
PVDF 22/26 39 115 96527114
Hose clamp 9/- 10 50 86 96440532
PVC FKM Glass
150 DN 10 Pipe cementing -/16 16 50 56 96440536
FKM Threaded Rp 3/4 Rp 3/4 39 115 96534450
Stainl. Hose clamp 9/- 10 50 86 96446727
Stainl. steel
steel CSM -/Rp 1/2 Rp 1/2 50 56 96446855
Threaded
-/1/2" NPT 1/2" NPT 50 56 96480625
Hose clamp 16/- 17 64 135 96440533
PVC FKM Glass
Pipe cementing -/20 20 64 94 96440537
375 DN 15 Hose clamp 16/- 16 64 135 96446856
Stainl.
CSM Stainl. steel -/Rp 1/2 Rp 1/2 64 94 96446857
steel Threaded
-/1/2" NPT 1/2" NPT 64 94 96480627
PP EPDM 33/42 57 167 96527115
32/41
PP FKM Glass Hose clamp 33/42 57 167 96527116
38/48
DN 20 PVDF FKM 33/42 57 167 96527118
Stainl.
FKM Stainl. steel Threaded Rp 1 1/4 Rp 1 1/4 57 167 96534454
steel
940
Hose clamp 25/- 26 90 175 96440534
PVC FKM Glass
Pipe cementing -/32 32 90 120 96440538
DN 25 Hose clamp 25/- 26 90 175 96446858
Stainl.
CSM Stainl. steel -/Rp 1 Rp 1 90 120 96446859
steel Threaded
-/1" NPT 1" NPT 90 120 96480628

29
Accessories Injection valve

Injection valve
Injection valve complete with non-return valve, injec-
tion pipe and tubing or pipe connection.
Spring material: Hastelloy
Opening pressure: DN 4, DN 8: 0.7 bar
DN 6, DN 10,
DN 15, DN 25: 1.1 bar
Max. temperature: PP, PVDF: 50°C
PVC: 40°C
Stainless steel: 80°C.

Dimensions
DN 4, DN 8 DN 6, DN 10, DN 15, DN 20, DN 25

d
L

TM01 9278 4802 - TM02 6434 0603

Non-return
valve

GR7098 - GR8107
TM01 9279 1600

Material Connection Dimensions


Max. flow rate Product
Size Inner/outer tubing or L Valve kit
[l/h] Housing Gasket Ball Type d number
pipe diameters [mm]
4/6 G 1/2 33 96440576
6/9 G 1/2 33 96440577
PP EPDM Ceramic Tubing 96499608
0.17"/1/4" 1/2" NPT 33 96480641
1/4"/3/8" 1/2" NPT 33 96479805
4/6 G 1/2 33 96446739
6/9 G 1/2 33 96446740
12 DN 4 PP FKM Ceramic Tubing 96499609
0.17"/1/4" 1/2" NPT 33 96480642
1/4"/3/8" 1/2" NPT 33 96479806
4/6 G 1/2 33 96440581
6/9 G 1/2 33 96440582
PV FKM Ceramic Tubing 96499600
0.17"/1/4" 1/2" NPT 33 96480643
1/4"/3/8" 1/2" NPT 33 96479807

30
Accessories Injection valve

Material Connection Dimensions


Max. flow rate Product
Size Inner/outer tubing or L Valve kit
[l/h] Housing Gasket Ball Type d number
pipe diameters [mm]
6/9 G 1/2 33 96446736
Tubing
9/12 G 1/2 33 96440578
-/10 G 1/2 33 96440574
PP EPDM Ceramic Pipe cementing 96499601
-/12 G 1/2 33 96440575
1/4"/3/8" 1/2" NPT 33 96480644
Tubing
3/8"/1/2" 1/2" NPT 33 96480645
6/9 G 1/2 33 96446741
Tubing
9/12 G 1/2 33 96446880
-/10 G 1/2 33 96446737
72 DN 8 PP FKM Ceramic Pipe cementing 96499602
-/12 G 1/2 33 96446738
1/4"/3/8" 1/2" NPT 33 96480646
Tubing
3/8"/1/2" 1/2" NPT 33 96479808
6/9 G 1/2 33 96446742
Tubing
9/12 G 1/2 33 96440583
-/10 G 1/2 33 96440579
PV FKM Ceramic Pipe cementing 96499603
-/12 G 1/2 33 96440580
1/4"/3/8" 1/2" NPT 33 96480647
Tubing
3/8"/1/2" 1/2" NPT 33 96479809
Hose clamp 6/- G 1/2 100 96446878
Stainl. Stainl. -/Rp 1/4 G 1/2 100 96446879
72 DN6 AF
steel steel Threaded -/1/4" NPT 1/2" NPT 100 96479804
-/1/2" NPT 1/2" NPT 100 96480629
PP EPDM G 3/4 105 96527119
19/27
PP FKM Ceramic Hose clamp G 3/4 105 96527120
25/34
PVDF FKM G 3/4 105 96527121
9/- G1 100 96440568
Hose clamp
16/- G1 100 96440567
PVC FKM Glass
-/12 G1 100 96440565
150 DN 10 Pipe cementing
-/16 G1 100 96440566
FKM Threaded Rp 3/4 G 3/4 105 96534457
Hose clamp 9/- G1 100 96446875
Stainl. Stainl.
-/Rp 3/8 G1 100 96446876
steel AF steel
Threaded -/Rp 1/2 G1 100 96446877
-/3/8"NPT 1" NPT 100 96480640
Hose clamp 16/- G1 100 96440571
375 DN 15 PVC FKM Glass -/16 G1 100 96440569
Pipe cementing
-/20 G1 100 96440570
PP EPDM G1 98 96527122
32/41
PP FKM Glass Hose clamp G1 98 96527123
38/48
DN 20 PVDF FKM G1 98 96527124
Stainl. Stainl.
FKM Threaded Rp 1 1/4 G1 98 96534459
940 steel steel
25/- G 1 1/2 100 96440573
Hose clamp
25"/- NPT 1.5" NPT 100 96480649
DN 25 PVC FKM PVDF
-/32 G 1 1/2 100 96440572
Pipe cementing
-/32" NPT 1.5" NPT 100 96480648

31
Accessories Hot injection valve

Hot injection valve


Complete hot injection valve kit with shut-off valve, pipe
and tubing connection fitting for chemical injection into
steam and hot water application.
The hot injection valve allows for direct dosing injection
into systems with temperature of maximum 150°C at
the injection valve point.
The hot injection valve kit is delivered non-assembled to
facilitate adaptation to the actual application.
Material:
Shut-off ball valve: Stainless steel 1.4401
Pipe: Stainless steel 1.4401

GR 7506
Pipe connection: Stainless steel 1.4401
Tubing connection: PVDF
Max. injection point temperature: 150°C.
Dimensions:
Shut-off ball valve: 1/2"
Pipe: 8/10 mm
Pipe connection: 1/2"
Tubing connection: 6/9.
Max. flow rate Material Connection Product
Size
[l/h] Connection Gasket Ball Type Tubing diameters number
20 DN 4 PVDF FKM Ceramic Tubing 6/9 96534472

32
Accessories Multifunction valve

Multifunction valve
Compact valve unit for direct mounting on the pump
discharge connection. The valve has four functions:
1. Constant counter-pressure.
The valve keeps the counter-pressure constant at 1.5
bar to optimise the dosing accuracy when dosing into
systems with fluctuating pressure or pressure-less
systems.
2. Anti-siphoning.
The valve prevents undesired siphoning when the
pump inlet pressure is higher than or equivalent to

TM01 9584 2100 - TM01 9583 2100 - TM01 8961 0900


the discharge pressure.
3. Pump protection.
The valve protects the pump against excessive pres-
sure by releasing the pressure in the pump head
when the discharge pressure exceeds 11 bar.
4. Manual pressure relief.
When the right knob is pulled, the pressure in the
pump head is relieved for priming or degassing.
When both knobs are pulled at the same time, the
pump head and the discharge line are relieved.
Relief pressure: 11 bar
Counter-pressure: 1.5 bar.

Dimensions

TM01 2220 1498

Materials Dimensions
Pump type Product number
Housing Gasket Diaphragm A E
EPDM PTFE G 5/8 Rp 5/8 96440590
DMM 4 PP
DMM 8 FKM PTFE G 5/8 Rp 5/8 96440591
DMM 15 PVDF FKM PTFE G 5/8 Rp 5/8 96440592
DMM 23
PVC FKM PTFE G 5/8 Rp 5/8 96446754
EPDM PTFE G 3/4 Rp 3/4 96440587
PP
DMM 48 FKM PTFE G 3/4 Rp 3/4 96440588
DMM 72 PVDF FKM PTFE G 3/4 Rp 3/4 96440589
PVC FKM PTFE G 3/4 Rp 3/4 96446753
1
M28 x 2 fits stainless steel pump heads.

33
Accessories Flow indicator

Flow indicator
The flow indicator is used for discharge monitoring.
When the dosing pump is discharging liquid, the white
ball will jump in the transparent pipe. Each dosing stroke
causes a ball jump. The flow indicator is designed so that
ball movements can be seen at flow rates from 0.1 to 45
l/h.
At a steady flow, the ball will always be in the top posi-
tion.
The flow indicator installs and retrofits easily.

TM01 9791 3100


Technical data
Material: PVC grey, PVC transparent,
PVDF, FKM, ceramic AI203
Maximum pressure: 10 bar
Maximum pulsed flow rate: 45 l/h.
Dimensions
TM01 9800 3200

Dimensions
Pump type Product number
A B C [mm] D [mm]
DMM 4 to DMM 23 G 5/8 Rp 5/8 41 51 96446761
DMM 48 to DMM 72 G 3/4 Rp 3/4 42 53 96446762

34
Accessories Pump connection

Pump connection
Separate retrofit pump connections for adapting
standard Grundfos pumps to installation-specific tubing
and pipe types and sizes.
The product number includes one connection with
unions and inserts.

GR6987
Inner/outer tubing
For pump type Connection type Material Product number
or pipe diameters/thread
4/6 Polypropylene 96440491
Tubing 6/9 Polypropylene 96440494
6/12 Polypropylene 96440500
DMM 4 PVC 96440504
DMM 8 Hose clamp 6/–
St. steel 1.4571 96440477
DMM 15
DMM 23 –/10 PVC 96440501
Pipe cementing
–/12 PVC 96440503
Polypropylene 96440505
Inner thread –/Rp 1/4
St. steel 1.4571 96440507
6/9 Polypropylene 96440492
Tubing
6/12 Polypropylene 96440495
PVC 96440499
Hose clamp 6/–
St. steel 1.4571 96440476
DMM 48
–/10 PVC 96440496
DMM 72
Pipe cementing –/12 PVC 96440497
–/16 PVC 96440498
Polypropylene 96440493
Inner thread –/Rp 1/4
St. steel 1.4571 96440506
PVC 96440482
Hose clamp 16/–
St. steel 1.4571 96440478
DMM 110 –/12 PVC 96440463
DMM 155
DMM 160 Pipe cementing –/16 PVC 96440479
DMM 210 –/20 PVC 96440483
DMM 260 Polypropylene 96440481
DMM 290 Inner thread –/Rp 1/2
DMM 390 St. steel 1.4571 96440484
PVC 96440466
Flange DN 15
St. steel 1.4571 96440485
Hose clamp 25/– PVC 96440465
–/32 PVC 96440487
Pipe cementing
DMM 440 –/40 PVC 96440490
DMM 640 Polypropylene 96440486
DMM 990 Inner thread –/Rp 1
St. steel 1.4571 96440488
Polypropylene 96440467
Flange DN 25
St. steel 1.4571 96440489
Fits only to stainless steel pumps.

35
Accessories Rigid suction line

Rigid suction line


Preassembled rigid suction line with adjustable length
for mounting in a tank. The suction line consists of foot
valve with strainer, rigid suction pipe, tank connection
thread and suction tubing.

TM01 9288 1600 - TM02 4551 1102


For control variant A, the suction line is available with
level sensors (NO) for warning and empty-tank signals,
supplied complete with cable and plug for pump connec-
tion.
Material: PVC
Suction tubing length: 1.5 m (PVC tube)
Level cable length: 1.5 m
Level plug type: M12, 4-pole
Maximum load of 
level contacts: 50 V, 0.5 A
Function of level contacts:
Low level/empty tank = closed contact
PE screw cap, ø33.5 mm:
Product number: 96483418.
Dimensions
With level sensors Without level sensors
TM01 2202 4701

TM01 2377 1498

Inner/outer suction Product number


Maximum length L For Grundfos tank size
tubing diameters
[mm] [l] With level sensors Without level sensors
[mm]
4/6 96441230 96417398
6/9 96441236 96417401
9/12 96449875 96449869
540 60
0.17"/1/4" 96480729 96480710
1/4"/3/8" 96479974 96480716
3/8"/1/2" 96480737 96480723
4/6 96441231 96446734
6/9 96441237 96446735
9/12 96449876 96449870
750 100
0.17"/1/4" 96480730 96480711
1/4"/3/8" 96480734 96480717
3/8"/1/2" 96480738 96480724
4/6 96441232 96417399
6/9 96441238 96417402
9/12 96449877 96449871
800 200
0.17"/1/4" 96480731 96480712
1/4"/3/8" 96479975 96480718
3/8"/1/2" 96480739 96480725

36
Accessories Rigid suction line

Inner/outer suction Product number


Maximum length L For Grundfos tank size
tubing diameters
[mm] [l] With level sensors Without level sensors
[mm]
4/6 96441233 96441222
6/9 96441239 96441224
9/12 96449878 96449872
900 300
0.17"/1/4" 96480732 96480713
1/4"/3/8" 96480735 96480719
3/8"/1/2" 96480000 96480726
4/6 96441228 96421285
6/9 96441234 96421286
9/12 96449873 96449867
1125 500
0.17"/1/4" 96480727 96480707
1/4"/3/8" 96479973 96480714
3/8"/1/2" 96479999 96480720
4/6 96441229 96417400
6/9 96441235 96417403
9/12 96449874 96449868
1250 1000
0.17"/1/4" 96480728 96480709
1/4"/3/8" 96480733 96480715
3/8"/1/2" 96480736 96480721

37
Acc_bas1.fm Page 38 Wednesday, May 12, 2004 8:56 AM

Accessories Level control unit

Level control unit


For dosing pumps with level control input, complete
with level sensors (NO), ceramic weight, cable and plug
for pump connection.
Material: PVC
Level cable length: 2.5 m
Level plug type: M12, 4-pole
Maximum load of
level contacts: 50 V, 0.5 A
Function of level contacts:
Low level/empty tank = closed contact
Product number: 96440539.
TM01 9587 2100

Dimensions
Level control unit
TM01 9567 1600

38
Accessories Counter-pressure or relief valve

Counter-pressure or relief valve


Adjustable valve for installation in the discharge tube.
• Installed in-line, the valve works as a counter-pres-
sure valve optimising dosing accuracy into systems
with fluctuating pressure or as anti-siphoning valve
when dosing into pressureless systems.
• Installed in a T-connection with the valve outlet con-
nected to the tank, the valve works as a pressure re-
lief valve or a safety valve, protecting the pump and
the discharge line against excessive pressures.

TM01 9289 1600


Pressure range: 0-10 bar
Diaphragm material: PTFE.

Dimensions, without connectors


DN 6, DN 10, DN 15 DN 25, DN 32, DN 40
TM01 9290 1600

TM01 9291 1600


Maximum Dimensions Connections
Size flow rate C H Housing material Product number
[l/h] A Type Inner/outer tubing or pipe diameters/thread
[mm] [mm]
4/6 96440823
6/9 96440825
6/12 96440824
Tubing 9/12 96489009
0.17"/1/4" 96487951
PVC
1/4"/3/8" 96487906
1/4"/1/2" 96487905
Pipe cementing -/10 96440821
-/Rp 1/4 96440822
Inner thread
1/4" NPT 96487950
DN 6 25 Rp 1/4 40 142 4/6 96440828
6/9 96440830
6/12 96440829
Tubing
0.17"/1/4" 96487908
PVDF 1/4"/3/8" 96487972
1/4"/1/2" 96487970
Pipe cementing -/10 96440826
-/Rp 1/4 96440827
Inner thread
1/4" NPT 96487907
-/Rp 1/4 96440831
St. steel 1.4571 Inner thread
-1/4" NPT 96487973

39
Accessories Counter-pressure or relief valve

Maximum Dimensions Connections


Size flow rate C H Housing material Product number
[l/h] A Type Inner/outer tubing or pipe diameters/thread
[mm] [mm]
6/9 96449892
Tubing 9/12 96504917
1/4"/3/8" 96487899
Hose clamp 9/- 96440799
PVC
-/12 96440796
Pipe cementing
-/16 96440797
-/Rp 3/8 96440798
Inner thread
-/3/8" NPT 96487898
6/9 96449893
DN 10 75 Rp 3/8 55 130 Tubing
1/4"/3/8" 96487941
Hose clamp 9/- 96440803
PVDF -/12 96440800
Pipe cementing
-/16 96440801
-/Rp 3/8 96440802
Inner thread
-/3/8" NPT 96487940
Hose clamp 9/- 96440805
St. steel 1.4571 -/Rp 3/8 96440804
Inner thread
-3/8" NPT 96487942
Hose clamp 16/- 96440807
Pipe cementing -/20 96440806
PVC
-/Rp 1/2 96440808
Inner thread
-/1/2" NPT 96487943
Hose clamp 16/- 96440810
DN 15 210 Rp 1/2 75 130 Pipe cementing -/20 96440809
PVDF
-/Rp 1/2 96440811
Inner thread
-/1/2" NPT 96487944
16/- 96440812
St. steel 1.4571 Hose clamp -/Rp 1/2 96440813
-/1/2" NPT 96487945
Hose clamp 25/- 96440815
-/Rp 1 96440814
PP
Inner thread 1/2" NPT 96487897
DN 25 390 Rp 1 140 240
-1"/ NPT 96487946
-/Rp 1 96440816
St. steel 1.4571 Inner thread
-/1" NPT 96487947
-/Rp 1 1/4 96440817
140 242 PP Inner thread
DN 32 640 Rp 1 1/4 -/1 1/4" NPT 96487948
170 165 St. steel 1.4571 Flange DN 32 96440818
-/Rp 1 1/2 96440819
252 PP Inner thread
DN 40 990 Rp 1 1/2 152 1 1/2" NPT 96487949
180 St. steel 1.4571 Flange DN 40 96440820

40
Accessories Valve assembly

Valve assembly
Complete assembly of either:
• counter-pressure and relief valve or
• relief and isolating valve.
Counter-pressure and relief valve
The pump discharge line is connected between the two
valves. One valve works as a counter-pressure valve opti-
mising dosing accuracy when dosing into systems with
fluctuating pressure or as anti-siphoning valve when

TM01 9588 2100


dosing into pressureless systems.
The outlet of the other valve is connected to the tank,
and the valve thus works as a pressure relief valve or a
safety valve protecting the pump and the discharge line
against excessive pressures.
Relief and shut-off valve
The pump discharge line is connected between the two
valves. The outlet of the counter-pressure valve is con-
nected to the tank, and the valve thus works as a pres-
sure relief valve or a safety valve protecting the pump
and the discharge line against excessive pressures. 
The shut-off valve can be used for interrupting the dos-
ing temporarily without stopping the pump. If the shut-
off valve is closed, the relief valve will return the dosed
liquid to the tank.
Valve diaphragm material: PTFE.
Pressure range of counter-pressure and relief valve: 
0-10 bar.

41
Accessories Valve assembly

Dimensions
Counter-pressure and isolating valve Counter-pressure and relief valve

TM01 9292 1600

TM01 9293 1600


Connection Dimensions
Maximum
Housing Inner/outer
Valve functions Size flow rate H Product number
material Type tubing or pipe A
[l/h] [mm]
diameters/thread
4/6 96440643
Counter-pressure
6/9 96440645
and isolating valve Tubing
6/12 96440644
PVC
DN 6 25 9/12 Rp 1/4 155 96488892
Pipe cementing -/10 96440641
Inner thread -/Rp 1/4 96440642
St. steel 1.4571 Inner thread -/Rp 1/4 96440646
Tubing 6/9 96449895
Hose clamp 9/– 96440596
PVC –/12 96440593
Pipe cementing 174
DN 10 75 –/16 Rp 3/8 96440594
Inner thread –/Rp 3/8 96440595
Hose clamp 9/– 96440598
St. steel 1.4571
Inner thread –/Rp 3/8 166 96440597
Hose clamp 16/– 96440600
TM01 9589 1600

PVC Pipe cementing –/20 96440599


180
DN 15 210 Inner thread –/Rp 1/2 Rp 1/2 96440601
Hose clamp 16/– 96440602
St. steel 1.4571
Inner thread –/Rp 1/2 163 96440603
4/6 96440845
Counter-pressure
Tubing 6/9 96440847
and relief valve
6/12 96440846
PVC
DN6 25 9/12 Rp 1/4 155 96489142
Pipe cementing -/10 96440843
Inner thread -/Rp 1/4 96440844
St. steel 1.4571 Inner thread -/Rp 1/4 96440848
Tubing 6/9 96449894
Hose clamp 9/– 96440835
PVC –/12 96440832
Pipe cementing 174
DN 10 75 –/16 Rp 3/8 96440833
Inner thread –/Rp 3/8 96440834
Hose clamp 9/– 96440837
St. steel 1.4571
Inner thread –/Rp 3/8 166 96440836
Hose clamp 16/– 96440839
TM01 9590 2100

PVC Pipe cementing –/20 96440838


180
DN 15 210 Inner thread –/Rp 1/2 Rp 1/2 96440840
Hose clamp 16/– 96440841
St. steel 1.4571
Inner thread –/Rp 1/2 163 96440842

42
Accessories Automatic venting valve

Automatic venting valve


Automatic venting valve for direct fitting to the pump
discharge connection.
Valve housing material: PMMA/PVC
O-ring material: FKM
Valve ball material: Glass
Valve seat material: PVDF
Pump head material: PP/PVDF
Power cable length: 1.5 m
Operating pressure: 10 bar
Supply voltage: 115/230 V, 50/60 Hz
Plug type: EU (Schuko).

TM01 9591 2100 - TM01 9592 2100


With timer:
The valve is continuously connected to the power
supply, and the opening time and opening intervals are
set on the timer.

Dimensions

TM01 2218 1498

Product number
Pump type Dimension A + B Voltage Power plug
With timer
Schuko (DIN) 96441086
1 x 230 V, 50-60 Hz Switzerland 96470745
DMM 5/8”
Australia 96470746
1 x 115 V, 50-60 Hz US 96441083

43
Accessories Pulsation dampener

Pulsation dampener
The pulsation dampener can be installed both in the
suction and the discharge line for reducing pressure
surges, thereby ensuring a steady flow. The dampener is
particularly suitable for long discharge lines and/or lines
with a small diameter.
Installed in the discharge line, the dampener can be used
for optimising dosing accuracy and for protection of
pump and discharge line against pressure surges.

TM01 9593 2100


Depending on the system pressure, it may be necessary
to install a counter-pressure valve after the dampener to
optimise its function.
Maximum pressure: 10 bar

Dimensions, without connections


Size 80 Size 250 Sizes 750 and 2500
TM01 2206 1498

TM01 2208 1498


TM01 2207 1498

Materials Connections Dimensions [mm]


Maximum
Inner/outer tubing Product
Size flow rate
Housing Diaphragm Type or pipe diameters/thread A B C D E number
[l/h]
[mm]
6/9 96441075
CSM Tubing
PP 9/12 96488893
FKM Tubing 6/9 96441074
80 72 6/9 172 G 3/4 M6 50 96441077
CSM Tubing
1/4"/3/8" 96480706
PVC
6/9 96441076
FKM Tubing
1/4"/3/8" 96479972
Inner thread -/Rp 1/2 96440850
CSM
Inner thread -/1/2" NPT 96480694
PP
Inner thread -/Rp 1/2 96440849
FKM
Inner thread -/1/2" NPT 96480693
250 260 314 140 G 1 1/4" M8 58
Inner thread -/Rp 1/2 96440854
CSM
Inner thread -/1/2" NPT 96480696
PVC
Inner thread -/Rp 1/2 96440852
FKM
Inner thread -/1/2" NPT 96480695
Inner thread -/Rp 1/2 96441071
CSM
Inner thread -/1/2" NPT 96480700
PP
Inner thread -/Rp 1/2 96441070
FKM
Inner thread -/1/2" NPT 96480698
750 390 363 347 G 1 1/4" ø9 72
Inner thread -/Rp 1/2 96441073
CSM
Inner thread -/1/2" NPT 96480704
PVC
Inner thread -/Rp 1/2 96441072
FKM
Inner thread -/1/2" NPT 96480703
CSM Pipe cementing -/40 96440856
PP
FKM Pipe cementing -/40 96440855
2500 990 541 525 G2 ø11 126
CSM Pipe cementing -/40 96440858
PVC
FKM Pipe cementing -/40 96440857

44
Accessories Accessories for pulsation dampeners

Accessories for pulsation dampeners


Connector
For direct mounting of pulsation dampener size 80 to
pump discharge connection.
Pump type A B C Product number
DMM 4
DMM 8
Rp ¾ G 5/8 32 96441088
DMM 15
DMM 23
DMM 48
Rp ¾ G¾ 30 96441087
DMM 72
TM01 9594 2100

TM01 2212 1498

Dummy plug
For installation of pulsation dampener in T-piece con-
nection.
Dimension [mm]
Pulsation damper size Product number
A
80 Rp ¾ 96441092
250
Rp 1¼ 96441091
750
2500 Rp 2 96441090
TM01 9595 2100

TM01 2211 1498

Pressure gauge
For measuring gas pressure in pulsation dampener.
Pressure range Product number
0-6 bar 96441096
0-16 bar 96441095
TM01 9596 2100

TM01 2209 1498

45
Accessories Priming aid

Priming aid
The priming aid is a transparent, air-tight collector with
a screw cap on top. It is mounted between the tank and
the pump. The inlet from the tank and the outlet to the
pump are both in the bottom of the collector.
The priming aid is supplied with a bracket for wall
mounting and a rod for mounting on top of the tank.
The priming aid has following functions:
• Priming.

TM01 9597 2100


To facilitate priming in case of frequent stops and/or
high suction lifts by eliminating or reducing the dry-
suction phase.
• Gas trap.
Gas occurring in the suction line is trapped in the top
of the priming aid to prevent it from entering the
pump head.
• Pulsation dampening.
The dampening gas cushion in the top of the priming
aid reduces pressure surges, resulting in optimum
dosing accuracy and reduced risk of cavitation.
Material: PVC.

Dimensions
Size 95 Size 250

TM01 2216 1498


TM01 2214 1498

Connections
Size/priming capacity
Inner/outer tubing diameters Product number
[ml] Type
[mm]
4/6 96441079
6/9 96441080
95
0.17"/1/4" 96480692
Tubing 1/4"/ 3/8" 96479970
6/9 96441078
250 9/12 96483949
1/4"/ 3/8" 96480690

46
Accessories Tank

Tank
Closed cylindrical tank with screw cap and bush for rigid
suction line. 
Material: PE.
Liquid temperature: Min. –20°C
Max. +45°C.
Pump mounting plate:
The pumps can be mounted directly on the tank top by
means of adapter plates.

TM01 9598 2100


DMM 4 to DMM 155: 96457099 (kit).
Floor mounting bracket:
Material: PE
Set of four: 96446767.
If the mixer is mounted on a Grundfos tank, a mounting
plate must be used:
Tank size [l] Product number
60 96467256
100 96467257
200 96467258
300 96467259
500 96467330
1000 96471403

Dimensions

Floor mounting bracket


TM01 2219 1498

Dimensions [mm]
Tank size [l] Weight [kg] Product number
D H
1
60 415 575 4.5 96417362
1001 470 790 7.0 96417363
2001 600 845 13.0 96417364
3002 675 950 15.0 96441296
5002 815 1080 27.0 96417365
10002 1080 1358 39.0 96417366
1 As drawing.
2 Does not have mounting holes in tank.

47
Accessories Hand mixer

Hand mixer
Hand mixer with adjustable length for mixing of chemi-
cals in a tank. The mixer is designed for Grundfos chem-
ical tanks.
Material: PVC.

TM01 9599 2100


Dimensions

TM01 2222 1498

Tank size [l] Maximum length L [mm] Product number


60 450 96417377
100 600 96417378
200 750 96417379
300 850 96446784
500 950 96417380
1000 1200 96417381

48
Accessories Electric mixer

Electric mixer
Electric mixers ensure homogeneous mixing of the
chemical solution in the tank. Mixing is essential for dis-
solving difficulty dilutable powder additives or liquid
additives. The mixer is equipped with a single or three-
phase motor, an mixer shaft connected directly to the
motor shaft and a three-blade mixing propeller.
The selection of the mixer size depends on whether
readily-soluble substances, or permanently poorly mis-
cible emulsions or insoluble suspensions are to be stabi-
lised. The latter require higher power input and, if

TM01 9790 3100


necessary, continuous operation instead of intermittent
operation.
The mixer must be protected against dry-running. If the
mixer is mounted on a Grundfos tank, a mounting
bracket must be used, see page 47.
Mixer shaft material: PTFE-coated stainless steel
DIN W.-Nr. 1.4571
Propeller material: PVDF
Motor insulation class: F
Enclosure class: IP 55.

Product number
Shaft length Voltage Motor size Speed
L [mm] Hz [kW] [min-1] PTFE-coated
Stainless steel
stainless steel
1 x 230 V, 50 Hz 0.09 1420 96446789 96449515
500
3 x 400 V, 50 Hz 0.12 1370 96446796 96449522
1 x 230 V, 50 Hz 0.09 1420 96446790 96449516
700
3 x 400 V, 50 Hz 0.12 1370 96446797 96449523
1 x 230 V, 50 Hz 0.09 1420 96446791 96449517
800
3 x 400 V, 50 Hz 0.12 1370 96446798 96449524
0.09 1420 96446792 96449518
1 x 230 V, 50 Hz
0.18 1450 96446793 96449519
900
0.12 1370 96446800 96449525
3 x 400 V, 50 Hz
0.25 1420 96446801 96449526
0.09 1420 96446794 96449520
1 x 230 V, 50 Hz
0.18 1450 96446795 96449521
1000
0.12 1370 96446802 96449527
3 x 400 V, 50 Hz
0.25 1420 96446804 96449528

Dimensions
Motor size Dimensions [mm]
[kW] A B C D E F G H
0.09
140 115 95 15 9 9.5 100 195
0.12
0.18
160 130 110 - 9 9.5 100 220
0.25

Sealing flange
When mixing aggressive liquids, the use of a sealing
flange for protection of the motor is recommended. The
sealing flange is made of polypropylene and sealed with
TM01 9806 3200

a V-ring. It fits 0.09 and 0.12 kW mixers.


Product number: 96446805.

49
Accessories Electric mixer

Water meter
In-line water meter with potential-free pulse signal for
use in flow-proportional dosing applications.
Meters from Qn 1.5 to Qn 2.5 are of the multi-jet, dry dial
type for cold water up to +30°C or hot water up to +90°C.
Meters from Qn 15 are of the helical vane type for cold
water up to +50°C or hot water up to +120°C.
Max. pressure: 16 bar.
If the water meter is to be connected directly to the
pump pulse input, a control plug should be used, see also
page 26.

GR5806p
Control plug product number: 96440449.
All meters Qn 1.5 to Qn 15 are supplied with threaded
connections.
All meters Qn 40 to Qn 150 are supplied with flange 
(8 holes) connections.
Cable length: 3 m.

Maximum Transitional Minimum Product number


Maximum
Qn Pulse rate short-period capacity with capacity Maximum water temperature
pressure
[m³/h] [l/pulse] capacity error with error
[bar] 30°C 50°C 90°C 120°C
[m³/h] ± 2% [l/h] ± 5% [l/h]
1.5 1 3 16 120 50 96446846 - 96446897 -
2.5 2.5 5 16 200 70 96446847 - 96446898 -
15 10 30 16 3000 450 - 96446848 - 96446899
1.5 0.25 3 16 120 50 96482640 - 96482643 -
2.5 0.25 5 16 200 70 96482641 - 96482644 -
15 2.5 30 16 3000 450 96482642 - 96482645 -
40 100 80 10 4000 700 - 96446849 - 96446900
60 25 120 10 6000 1200 - 96446850 - 96446901
150 100 300 10 12000 3000 - 96446851 - 96446902

Maximum load, reed contact: 30 VAC/VDC, 0.2 A.

Maximum load, namur contact: 8-12 VDC, 1 kohm (needs external power supply).

Dimensions
Connection Connection of Meter port-to-port Port-to-port length
Size
of meter installation kit length [mm] incl. kit [mm]
Threaded connection
Qn 1.5 G 3/4 Rp 1/2 165 245
Qn 2.5 G1 Rp 3/4 190 288
Qn 15 G 2.5 Rp 2 300 438
Flange connection
Qn 40 DN 80 - 225 -
Qn 60 DN 100 - 250 -
Qn 150 DN 150 - 300 -

50
Pumped liquids DMM

List of pumped liquids The data shown here is based upon information from
various sources available, but be aware that many
This resistance table is intended to serve as a general factors (purity, temperature, abrasive particles etc.) can
guide only for material resistance (at room temperature) affect the chemical resistance of a given material.
and is not a substitute for actual testing of the chemicals
Remember also that some of the liquids in this table may
and pump materials under specific working conditions.
be toxic, corrosive or hazardous.
Please be careful when handling these liquids.
Materials
Pump housing Gasket Ball

Stainl. steel

Cen tellen C
Pumped liquid 20°C Concentration %

Ceramic
1.4401

EPDM

Glass
PVDF

PTFE
FKM

CSM
PVC
PP
25 z z z z – z  z z z z
Acetic acid CH3COOH 60 z z z z –  – z  z z
85 z z z – – – – z  z z
Aluminium chloride AlCl3 40 z z – z z z z z z z z
Aluminium sulphate Al2(SO4)3 60 z z z z z z z z z z z
Ammonia, aqueous NH4OH 28 z z z z – z z z  z –
Calcium hydroxide7 Ca(OH)2 z z z z z z z z z z –
Calcium hypochlorite Ca(OCl)2 20  z – z z z z z z z z
10 z z z z z z z z z z z
30 – z – z z  z z  z z
Chromic acid5 H2CrO4
40 – z – z z – z z  z z
50 – z – z z – z z  z z
Copper sulphate CuSO4 30 z z z z z z z z z z z
Ferric chloride3 FeCl3 100 z z – z z z z z z z z
Ferric sulphate3 Fe2(SO4)3 100 z z z z z z z z z z z
Ferrous chloride FeCl2 100 z z – z z z z z z z z
Ferrous sulphate FeSO4 50 z z z z z z z z z z z
< 25 z z – z  z z z z z z
Hydrochloric acid HCl
25-37 z z – z – z – z  z z
Hydrogen peroxide H 2O2 30 z z z z z z z z z z z
10 z z z z z z z z z z z
30 z z z z z z z z – z z
Nitric acid HNO3
40  z z z z z – z – z z
70 – z z – z – – z – z z
Peracetic acid CH3COOOH 5 z z – z – z z z z z z
Potassium hydroxide KOH 50 z – z z – z z z  z –
Potassium permanganate KMnO 4 10 z z z z – z z z z z z
Sodium chlorate NaClO3 30 z z z z  z z z z z
Sodium chloride NaCl 30 z z – z z z z z z z z
Sodium chlorite NaClO2 20 z  – – z z z z z z z
20 z  z z z z z z  z –
Sodium hydroxide NaOH 30 z – z z z z z z  z –
50 z – z z z z z z  z –
Sodium hypochlorite NaOCl 20  z – z z z z z z z z
Sodium sulphide Na 2S 30 z z z z z z z z z z –
Sodium sulphite6 Na2SO3 20 z z z z z z z z z z –
Sulphurous acid H 2SO3 6 z z z z z z z z z z 
< 80 z z –  z  z z  z 
Sulphuric acid4 H2SO4
80-98  z – – z – – z z z –
z Suitable. 3 Risk of crystallisation.

 Limited. 4 Reacts violently with water and generates much heat. 


(Pump should be absolutely dry before dosing sulphuric acid.)
– Not suitable. 5 Must be fluoride-free when glass balls are used.
6 In neutral solutions.
7 Saturated solution 0.1%.

51
Being responsible is our foundation
Thinking ahead makes it possible
Innovation is the essence

96 53 60 29 05 04
Repl.: V7 16 40 97 06 03
GB Subject to alterations.

GRUNDFOS A/S . DK-8850 Bjerringbro . Denmark


Telephone: +45 87 50 14 00.

www.grundfos.com