Download as pdf or txt
Download as pdf or txt
You are on page 1of 55

Digital Catalog

Click here to display the contents. Click here to download the PDF file.

Operation can be made from the toolbar


at the center of the lower portion of the screen.
Intrinsically Safe Explosion-proof System
5 Port Solenoid Valve

Can be used as a certified intrinsic safety type product only in Japan.

Exia@BT4 (TIIS approved product)


This product has been certified as an intrinsic safety type system consisting of an electromagnet
for a solenoid valve in combination with a safety retainer, for type approval as an explosion proof
electric apparatus by Technology Institution of Industrial Safety (TIIS).

Series 51-SY5000/7000/9000
CAT.ES11-90B B
51-SY-B.qxd 09.3.18 11:10 AM Page 2

Compact, High Flow


B

L3
A
Dimensions
Dimension
Model L1 L2 L3
51-SY5120-L
L1

104
51-SY5120-LL 15
51-SY5120-TT 120.8
40
L2
51-SY7120-L
118.2
51-SY7120-LL 18
51-SY7120-TT 135
51-SY9120-L
148.3
51-SY9120-LL 42 23
51-SY9120-TT 165.1

L2

Flow-rate Characteristics
Flow-rate characteristics
Series 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB)
C[dm3/(s·bar)] b Cv C[dm3/(s·bar)] b Cv
51-SY520 1.9 0.35 0.49 2.4 0.39 0.61
Body ported 51-SY720 4.1 0.23 0.93 3.3 0.33 0.81
51-SY920 7.0 0.33 1.7 7.6 0.35 2.0
51-SY540 2.4 0.41 0.64 2.8 0.29 0.66
Base mounted 51-SY740 4.1 0.41 1.1 4.1 0.29 1.0
51-SY940 7.9 0.34 2.0 9.6 0.43 2.6

Features 1
3 Types of Connectors
쎲 Easily maintained by adapting connector 쎲 IP65 compliant
for the lead wire (L- and LL-type) (TT-type)

L-type

LL-type

L-type plug connector (L-type) L-type plug connector with cover (LL-type) Terminal type (TT-type)

3 Types of Barriers

Zener diode type Insulating type

Features 2 B
Intrinsically Safe Explosion-proof System
5 Port Solenoid Valve
Series 51-SY5000/7000/9000
Body Ported
Single Unit
How to Order

51 SY 5 1 20 A LL 3 01
Series Bracket
5 51-SY5000 Thread type Nil: Without bracket
F1: With foot bracket
7 51-SY7000 Nil Rc
2-position
9 51-SY9000 F G single only
N NPT
Explosion-proof
T NPTF
Intrinsically safe
51 explosion-proof
structure
A, B port size
Thread piping
Type of actuation Symbol Port size Applicable series
2-position single 01 1/8 51-SY5000
F2: With side bracket
02 1/4 51-SY7000
1
02 1/4
51-SY9000
03 3/8
2-position double One-touch fitting (Metric size) Note)
Symbol Port size Applicable series
2
C4 ø4 one-touch fitting ∗ The 51-SY9000 has no
C6 ø6 one-touch fitting 51-SY5000 bracket.
3-position closed center C8 ø8 one-touch fitting
C8 ø8 one-touch fitting
3 Note) 51-SY7000
C10 ø10 one-touch fitting
C8 ø8 one-touch fitting Note) Warning
3-position exhaust center C10 ø10 one-touch fitting 51-SY9000 If a resin tube is used,
C12 ø12 one-touch fitting take measures against
Note)
4 static electricity.

Manual override
3-position pressure center Nil: Non-locking push D: Push-turn locking E: Push-turn locking
type slotted type lever type
Note)
5

Note) 3-position type is not available


for the 51-SY9000 series.

System Note 1) Note 2)


Lead wire length
A Z728.H (51-SYE100-A)
Electrical entry Symbol Lead wire length Note
B MTL728P + (51-SYE100-B)
Symbol Electrical entry 3 300 mm —
F KFD0-SD2-Ex1.1065 (51-SYE100-F)
6 600 mm Maximum length for L-type
Note 1) Attached barrier type L-type plug connector
The numbers in ( ), 51-SYE100-쏔 10 1000 mm —
represents SMC’s control number. L 15 1500 mm —
Note 2) If the barrier is not necessary due to 20 2000 mm —
valve replacement etc, enter O after the 3000 mm —
30
system symbol.
Example) 51-SY5120-AOLL3-01 100 10000 mm Semi-standard
L-type plug connector
with cover
LL

Terminal type

TT Note)

Note) The lead wire of TT-type is


connected to the terminal block.
B 1
Body Ported Series 51-SY5000/7000/9000

Specifications

Series 51-SY5000 51-SY7000 51-SY9000


Fluid Air
Internal pilot 2-position single 0.15 to 0.7
operating pressure 2-position double 0.1 to 0.7
range (MPa) 3-position 0.2 to 0.7
Ambient and fluid temperature (°C) –10 to 50 (No freezing)
Max. operating 2-position single, double 5
frequency (Hz) 3-position 3
Non-locking push type,
Manual override (Manual operation) Push-turn locking slotted type,
Push-turn locking lever type
Pilot exhaust method Main/Pilot valve common exhaust
Lubrication Not required
Mounting orientation Unrestricted
Impact/Vibration resistance (m/s2) Note) 150/30
Enclosure IP30 (L-type), IP40 (LL-type), IP65 (TT-type)
∗ Based on IEC60529
Note) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right
angles to the main valve and armature in both energized and de-energized states
every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was
performed at both energized and de-energized states in the axial direction and at
the right angles to the main valve and armature. (Values at the initial period)

Solenoid Specifications

L-type plug connector (L),


Electrical entry L-type plug connector with cover (LL),
Terminal type (TT)
Coil rated voltage 12 VDC
Allowable voltage fluctuation –10% to +10% of rated voltage
Coil insulation type Class B
Power consumption 0.52 W (at rated voltage)

Intrinsically Safe Explosion-proof System Specifications

Type of explosion-proof structure Intrinsically safe explosion-proof structure (ia) Note 1)


Applicable gas or ignition temperature
IIBT4
of steam and explosion class
Voltage to barrier 24 VDC (rated voltage of system) Note 2) Note 3)
Tolerant voltage fluctuation Refer to the barrier dimensions on page 41 and 42.
Note 1) Warning Can not be used in a class-0 environment. Use in a class-2 or class-1 environ-
ment.
Note 2) Caution The valve and barrier have polarity. If voltage is supplied with wrong polarity,
the barrier can not be used.
Note 3) Caution Voltage to the valve should be 10.8 VDC (minimum value).

Response Time
Note) Based on dynamic performance test, JIS B 8375-1981.
(Coil temperature: 20°C, system A, B, F at 24 VDC)

Response time (ms) (at 0.5 MPa)


Type of actuation
51-SY5000 51-SY7000 51-SY9000
2-position single 26 or less 38 or less 50 or less
2-position double 22 or less 30 or less 50 or less
3-position 38 or less 56 or less —

2A
51-SY-B.qxd 09.3.18 11:10 AM Page 6

Series 51-SY5000/7000/9000

Flow-rate Characteristics
Series 51-SY5000 Series 51-SY9000
Port size Flow-rate characteristics Note) Port size Flow-rate characteristics
Valve Type of Valve Type of
1, 5, 3 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB) 1, 5, 3 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB)
model actuation C(dm3/ C(dm3/ model actuation C(dm3/ C(dm3/
(P, EA, EB) (A, B) b Cv b Cv (P, EA, EB) (A, B)
(s·bar)) (s·bar)) (s·bar)) b Cv (s·bar)) b Cv
2- Single
position Double 1.9 0.35 0.49 2.4 0.39 0.61 51-SY9 2- Single
Closed 20- position 1/4 7.0 0.33 1.7 7.6 0.35 2.0
51-SY5 1.7 0.43 0.45 1.8 0.35 0.46 -02 Double
center
20- 3- Exhaust 1/8
-01 position center 1.5 0.44 0.41 2.5 0.32 0.59
[1.5] [0.43] [0.40] 51-SY9 2- Single
Pressure 2.2 0.46 0.61
1.8 0.38 0.46
20- position 3/8 8.0 0.29 1.9 8.0 0.33 2.0
center [0.91] [0.58] [0.28] -03 Double
2- Single 0.75 0.43 0.20 0.85 0.64 0.30
position Double C4 C8
Closed Single ø8
51-SY5 ø4 0.74 0.40 0.19 0.84 0.57 0.28 51-SY9 2-
20-
center one- 20- one- 4.3 0.28 0.96 7.1 0.32 1.7
-C4
3- Exhaust touch 0.75 0.36 0.19 0.84 0.64 0.30 -C8 position touch
position center [0.84] [0.53] [0.27] Double 1/4 fitting
fitting
Pressure 0.78 0.44 0.21 0.84 0.57 0.27
center [0.71] [0.37] [0.18] C10
1/8 Single ø10
2- Single 1.5 0.33 0.33 2.0 0.37 0.52
51-SY9 2-
position Double C6 20- one- 6.1 0.28 1.4 7.9 0.33 1.9
Closed ø6 -C10 position touch
51-SY5 1.3 0.31 0.33 1.6 0.32 0.39 Double fitting
center one-
20- 3- Exhaust
-C6 position center
touch 1.3 0.33 0.33 1.8 0.35 0.44 C12
fitting [1.4] [0.37] [0.35]
Double ø12
Pressure 1.7 0.31 0.42 51-SY9 2-
center 1.7 0.33 0.44 20- one- 7.0 0.25 1.6 8.6 0.41 2.2
[0.80] [0.47] [0.23]
2- Single -C12 position touch
1.9 0.21 0.45 2.3 0.29 0.57 Single fitting
position Double C8
Closed ø8 1.6 0.29 0.39 1.7 0.38 0.46
51-SY5 center
20- one-
3- Exhaust
-C8 position center
touch 1.4 0.38 0.39 2.0 0.37 0.52
fitting [1.5] [0.41] [0.43]
Pressure 2.2 0.32 0.56
center 1.8 0.41 0.50
[1.6] [0.44] [0.44]
Note) [ ]: Normal position

Series 51-SY7000
Port size Flow-rate characteristics Note)
Valve Type of
1, 5, 3 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB)
model actuation 3 C(dm3/
(P, EA, EB) (A, B) C(dm / b Cv b Cv
(s·bar)) (s·bar))
2- Single 4.1 0.23 0.93 3.3 0.33 0.81
position Double
Closed 2.9 0.31 0.70 2.4 0.38 0.63
51-SY7 center
20- 3- Exhaust 1/4
-02 2.5 0.39 0.65 [2.1] 3.4 0.35 0.82
position center [0.38] [0.54]
Pressure 4.3 0.23 0.97
center 2.2 0.39 0.58
[2.4] [0.32] [0.61]
2- Single 1 (P) 3.2 0.26 0.77 3.2 0.37 0.82
position Double port C8
Closed 1/4 ø8 2.6 0.24 0.63 2.4 0.31 0.62
51-SY7 center
20- one-
3- Exhaust 5, 3
-C8 position center (EA, EB)
touch 2.4 0.25 0.57 2.6 0.42 0.70
fitting [1.9] [0.46] [0.56]
Pressure port 3.3 0.28 0.78
center 1/8 [2.4] [0.22] [0.57] 2.2 0.34 0.60
2- Single 3.8 0.26 0.86 3.2 0.34 0.82
position Double C10
Closed ø10 2.8 0.27 0.67 2.4 0.21 0.59
51-SY7 center one-
20- 3- Exhaust touch
-C10 position center 2.5 0.25 0.59 2.7 0.38 0.70
fitting [2.0] [0.38] [0.56]
Pressure 3.8 0.25 0.89
center [2.4] [0.31] [0.61] 2.3 0.38 0.61
Note) [ ]: Normal position

3
51-SY-B.qxd 09.3.18 11:10 AM Page 7

Body Ported Series 51-SY5000/7000/9000

Construction
Series SY
2-position single
Symbol
w ry q e
2-position single (A) (B)
4 2

5 1 3
(EA) (P) (EB) t

Symbol
2-position double 2-position double
w y qr
(A) (B)
4 2

5 1 3
(EA) (P) (EB) t
Symbol 3-position closed center/exhaust center/pressure center
3-position closed center

wy qr
(A) (B)
4 2
3-position exhaust center

3-position pressure center 5 1 3


(EA) (P) (EB) t
(This figure shows a closed center type.)

How to Change Port Block Assembly


Component Parts If using body ported type, both A and B port sizes can be changed by
No. Description Material Note replacing the port block assembly mounted on the body. When changing
1 Body Aluminum die-casted White this block assembly, the correct screw torque must be achieved to avoid
possible air leakage.
White
2 Adapter plate Resin  51-SY5000 Port block assembly
(51-SY9000: Gray) Fitting
Port block assembly (Cassette type) assembly
3 End plate Resin White (Threaded type)
4 Piston Resin —
5 Spool valve assembly Aluminum, HNBR —
Mounting screw

Replacement Parts
No. Description Part no.
Refer to “How to Order Port Block
6 Port block assembly
Assembly” on page 5.

Bracket Assembly Part No.


Description Part no.
5
Bracket (for F1) SX 7000-16-2A (with mounting screw)
Bracket (for F2)
5
SX 7000-16-1A (with mounting screw) Caution
∗ The 51-SY9000 has no bracket. Mounting screw tightening torques
5
51-SY7 000 (M3): 0.6 N· m ∗ Refer to “How to Order
Port Block Assembly” on
51-SY9000 (M4): 1.4 N · m page 5 for part number.
4
51-SY-B.qxd 09.3.18 11:11 AM Page 8

Series 51-SY5000/7000/9000

How to Order Port Block Assembly

SY 000 6A
Series
5 51-SY5000 Thread type
7 51-SY7000 Nil Rc
9 51-SY9000 F G
N NPT
T NPTF

A, B port size
Thread piping
Symbol Port size Applicable series
01 1/8 51-SY5000
02 1/4 51-SY7000
02 1/4
51-SY9000
03 3/8
One-touch fitting (Metric size) One-touch fitting (Inch size)
Symbol Port size Applicable series Symbol Port size Applicable series
C4 ø4 one-touch fitting N3 ø5/32" one-touch fitting
C6 ø6 one-touch fitting 51-SY5000 N7 ø1/4" one-touch fitting 51-SY5000
C8 ø8 one-touch fitting N9 ø5/16" one-touch fitting
C8 ø8 one-touch fitting N9 ø5/16" one-touch fitting
51-SY7000 51-SY7000
C10 ø10 one-touch fitting N11 ø3/8" one-touch fitting
C8 ø8 one-touch fitting N9 ø5/16" one-touch fitting
51-SY9000
C10 ø10 one-touch fitting 51-SY9000 N11 ø3/8" one-touch fitting
C12 ø12 one-touch fitting

∗ Only the fitting assembly replacement is also possible.


Metric size Inch size
ø4 one-touch fitting VVQ1000-51A-C4 ø5/32" one-touch fitting VVQ1000-51A-N3
51-SY5000 ø6 one-touch fitting VVQ1000-51A-C6 51-SY5000 ø1/4" one-touch fitting VVQ1000-51A-N7
ø8 one-touch fitting VVQ1000-51A-C8 ø5/16" one-touch fitting VVQ1000-51A-N9
ø8 one-touch fitting VVQ2000-51A-C8 ø5/16" one-touch fitting VVQ2000-51A-N9
51-SY7000 51-SY7000
ø10 one-touch fitting VVQ2000-51A-C10 ø3/8" one-touch fitting VVQ2000-51A-N11
ø8 one-touch fitting VVQ4000-50B-C8 ø5/16" one-touch fitting VVQ4000-50B-N9
51-SY9000
51-SY9000 ø10 one-touch fitting VVQ4000-50B-C10 ø3/8" one-touch fitting VVQ4000-50B-N11
ø12 one-touch fitting VVQ4000-50B-C12

Mounting
screw
Port block assembly
(Cassette type)
Fitting
assembly

Warning If a resin tube is used, take measures against static electricity.

5
51-SY-B.qxd 09.3.18 11:11 AM Page 9

Body Ported Series 51-SY5000/7000/9000

Dimensions: 51-SY5000
2-position single With foot bracket
L-type plug connector (L) 51-SY5120-L-01-F1
51-SY5120-L-01 (-F2)
22.6 21
47

16.7
38 4.5

16.6
22
29
2 x M3 x 0.5 thread depth 3.5
(For mounting bracket) 14.7 2 x ø3.2
65 40 (For mounting)

11.6
Insulator: Black (–)

B
A

Insulator: Red (+)


Manual override 16.2 2 x ø3.2
36 (manifold mounting hole)
2 x 1/8"
(2 x ø3.2 mounting hole) {A(4), B(2) port}
(37)

111.8
44 (E-type)

0.3 mm2
14.7

(40.2)
(36.7)
40

32.5
20.5
ø1.55

(1.2) (32.3)

1.2
L (Lead wire length) 109.1
(11.7)
32.5 10.5
3 x 1/8" 32.3
0.8

{P(1), EA(5), EB(3) port}


1.6

(20)
15

EA P EB

2 x ø2.2
(For manifold gasket positioning) 27.2
(45)

L-type plug connector with cover (LL)


51-SY5120-LL-01 (-F2)
Insulator: Red (+)
Insulator: Black (–)
ø4.1

14.7

0.3 mm2

L (Lead wire length) 104

Terminal type (TT)


51-SY5120-TT-01 (-F2)
Lead wire marking
No.1 (+), No.2 (–)
ø5.9

12

0.75 mm2

L (Lead wire length) 120.8

Max.10

6
51-SY-B.qxd 09.3.18 11:11 AM Page 10

Series 51-SY5000/7000/9000

Dimensions: 51-SY5000
2-position double
22.6
L-type plug connector (L)
51-SY5220-L-01 (-F2)

16.7
2 x M3 x 0.5 thread depth 3.5
(For mounting bracket)
65.4

11.6
Insulator: Black (–)

B
A

Insulator: Red (+)


2 x ø3.2
Manual override 16.2
(manifold mounting hole)
36
2 x 1/8"
{A(4), B(2) port}

37 (2 x ø3.2 mounting hole)


44 (E-type)

0.3 mm2

(36.7)
40

32.5
(40.2)

20.5
14.7

ø1.55

(1.2) L (Lead wire length) 153.6


(11.7)
3 x 1/8"
(76.8)
{P(1), EA(5), EB(3) port}
0.8
1.6

(20)
15

EA P EB

27.2
2 x ø2.2
(For manifold gasket positioning) (45)

L-type plug connector with cover (LL)


51-SY5220-LL-01 (-F2)

L (Lead wire length) 143.4

Insulator: Red (+)


Insulator: Black (–)
ø4.1

0.3 mm2
14.7

(71.7)

Terminal type (TT)


51-SY5220-TT-01 (-F2)
Max.10

L (Lead wire length) 177

Lead wire marking


ø5.9

No.1 (+), No.2 (–)

0.75 mm2
12

(88.5)

7
51-SY-B.qxd 09.3.18 11:11 AM Page 11

Body Ported Series 51-SY5000/7000/9000

Dimensions: 51-SY5000
3-position closed center/exhaust center/pressure center
L-type plug connector (L) 22.6
3
51-SY5 45 20-L-01 (-F2)

16.7
2 x M3 x 0.5 thread depth 3.5
(For mounting bracket)
(89.4)
32.7 45.3

11.6
Insulator: Black (–)

B
A

Insulator: Red (+)


2 x ø3.2
16.2
Manual override (manifold mounting hole)
36
2 x 1/8"
{A(4), B(2) port}

(37)
(2 x ø3.2 mounting hole)

0.3 mm2
44 (E-type)

(36.7)
40

32.5
(40.2)

20.5
14.7

ø1.55

(1.2) L (Lead wire length) 166.2


(11.7)
3 x 1/8"
89.4
{P(1), EA(5), EB(3) port}
0.8
1.6

(20)
15

EA P EB

27.2
2 x ø2.2
(For manifold gasket positioning) (45)

L-type plug connector with cover (LL)


3
51-SY5 45 20-LL-01 (-F2)
L (Lead wire length) 156

Insulator: Red (+)


Insulator: Black (–)
ø4.1

0.3 mm2
14.7

84.3

Terminal type (TT)


3
51-SY5 45 20-TT-01 (-F2)
Max.10
L (Lead wire length) 189.6

Lead wire marking


No.1 (+), No.2 (–)
ø 5.9

0.75 mm2
12

101.1

8
51-SY-B.qxd 09.3.18 11:11 AM Page 12

Series 51-SY5000/7000/9000

Dimensions: 51-SY7000
2-position single With foot bracket
L-type plug connector (L) 51-SY7120-L-02-F1
51-SY7120-L-02 (-F2)
2 x M4 x 0.7 thread depth 6.5 20 29.4 57
(For mounting bracket) 46 5.5

19.8
28
38
14.7
79.2
40

13.6
Insulator: Black (–) Manual override
B

A
Insulator: Red (+)
2 x ø4.2
20
(manifold mounting hole)
42 2 x 1/4"
44 (E-type)

(14) {A(4), B(2) port}


1.2 (52)
(2 x ø4.2 mounting hole)

125
(49.5)

0.3 mm2
(42.5)
40

40
24.5
14.7

(39.4)
L (Lead wire length) 123.3

1.2
1/4"
{P(1) port} 40 12.5
2 x 1/8"
0.9

EA(5), EB(3) port} 39.4


2

(23.9)
18

EA P EB

36
2 x ø2.2
(For manifold gasket positioning) (66)

L-type plug connector with cover (LL)


51-SY7120-LL-02 (-F2)

Insulator: Red (+)


Insulator: Black (–)
ø4.1

14.7

0.3 mm2

L (Lead wire length) 118.2

Terminal type (TT)


51-SY7120-TT-02 (-F2)
Lead wire marking
No.1 (+), No.2 (–)
ø5.9

12

0.75 mm2

L (Lead wire length) 135


Max.10

9
51-SY-B.qxd 09.3.18 11:11 AM Page 13

Body Ported Series 51-SY5000/7000/9000

Dimensions: 51-SY7000
2-position double
L-type plug connector (L) 2 x M4 x 0.7 thread depth 6.5 20
(For mounting bracket)
51-SY7220-L-02 (-F2)

7
79.6
Insulator: Black (–)
B

13.6
A
Insulator: Red (+)
Manual override 2 x ø4.2
20
(manifold mounting hole)
42
2 x 1/4"
{A(4), B(2) port}
(52)
(2 x ø4.2 mounting hole)
44 (E-type)

0.3 mm2

(42.5)
(49.5)
40

40
24.5
14.7

ø1.55

(1.2)
(14) L (Lead wire length) 167.8

1/4"
{P(1) port}
2 x 1/8" (83.9)
{EA(5), EB(3) port}
0.9
2

18

EA P EB
(23.9)

2 x ø2.2 36
(For manifold gasket positioning) (66)

L-type plug connector with cover (LL)


51-SY7220-LL-02 (-F2)
L (Lead wire length) 157.6

Insulator: Red (+)


ø4.1

Insulator: Black (–)

0.3 mm2
14.7

(78.8)

Terminal type (TT)


51-SY7220-TT-02 (-F2)
Max.10
L (Lead wire length) 191.2

Lead wire marking


No.1 (+), No.2 (–)
ø5.9

0.75 mm2
12

(95.6)

10
51-SY-B.qxd 09.3.18 11:11 AM Page 14

Series 51-SY5000/7000/9000

Dimensions: 51-SY7000
3-position closed center/exhaust center/pressure center
L-type plug connector (L)
3 2 x M4 x 0.7 thread depth 6.5 20
51-SY7 45 20-L-02 (-F2) (For mounting bracket)

7
39.8 52.8
Insulator: Black (–)
B

13.6
A
Insulator: Red (+)
Manual override 2 x ø4.2
20
(manifold mounting hole)
42
2 x 1/4"
{A(4), B(2) port}
(52)
(2 x ø4.2 mounting hole)
ø1.55

44 (E-type)

0.3 mm2

(42.5)
(49.5)
40

24.5
40
14.7

(1.2) L (Lead wire length) 180.8


(14)
1/4"
{P(1) port} 96.9
2 x 1/8"
0.9

{EA(5), EB(3) port}


18

EA P EB
2

36
(23.9)

2 x ø2.2
(For manifold gasket positioning) (66)

L-type plug connector with cover (LL)


3
51-SY7 45 20-LL-02 (-F2)
L (Lead wire length) 170.6

Insulator: Red (+)


ø4.1

Insulator: Black (–)

0.3 mm2
14.7

91.8

Terminal type (TT)


3
51-SY7 45 20-TT-02 (-F2)
Max.10
L (Lead wire length) 204.2

Lead wire marking


No.1 (+), No.2 (–)
ø5.9

0.75 mm2
12

108.6

11
51-SY-B.qxd 09.3.18 11:11 AM Page 15

Body Ported Series 51-SY5000/7000/9000

Dimensions: 51-SY9000
2-position single
L-type plug connector (L)
03 
51-SY9120-L- 02
109.3
6.5 (56.3)
Insulator: Black (–)

4 A 2 B

18.4
Insulator: Red (+)
Manual override
33.6 3 x ø3.2
64.2 (manifold mounting hole)
2 x 1/4", 3/8"
{4(A), 2(B) port}
46 (E-type)

0.3 mm2

51.5
42

36.6
16.7

ø1.55

10
(12) 2 x ø4.4 24.9 43.85
(Mounting hole)
L (Lead wire length) 153.4

3 x 1/4" 56.3
0.5

{1(P), 3(EB), 5(EA) port}


23

5 EA 1 P 3 EB
0.5

49.8

L-type plug connector with cover (LL)


03 
51-SY9120-LL- 02

Insulator: Red (+)


ø4.1

Insulator: Black (–)


16.7

0.3 mm2

L (Lead wire length) 148.3

Terminal type (TT)


03 
51-SY9120-TT- 02

Lead wire marking


No.1 (+), No.2 (–)
14

0.75 mm2

L (Lead wire length) 165.1

Max.10

12
51-SY-B.qxd 09.3.18 11:11 AM Page 16

Series 51-SY5000/7000/9000

Dimensions: 51-SY9000
2-position double
L-type plug connector (L)
03 
51-SY9220-L- 02
106
6.5
Insulator: Black (–)

18.4
4 A 2 B

Insulator: Red (+)


Manual override 3 x ø3.2
33.6
(manifold mounting hole)
64.2
2 x 1/4", 3/8"
{4(A), 2(B) port}

46 (E-type)

0.3 mm2

51.5
42

36.6
16.7

ø1.55

10
(12) 2 x ø4.4 24.9
(Mounting hole)
L (Lead wire length) 194.2

97.1
3 x 1/4" 0.5
{1(P), 3(EB), 5(EA) port}
23

5 EA 1 P 3 EB
0.5

49.8

L-type plug connector with cover (LL)


03 
51-SY9220-LL- 02

Insulator: Red (+)


ø4.1

Insulator: Black (–)


16.7

0.3 mm2

L (Lead wire length) 184

Terminal type (TT)


03 
51-SY9220-TT- 02

Lead wire marking


No.1 (+), No.2 (–)
14

0.75 mm2

L (Lead wire length) 217.6

Max.10

13
Intrinsically Safe Explosion-proof System
5 Port Solenoid Valve
Series 51-SY5000/7000/9000
Base Mounted
Single Unit
How to Order

51 SY 5 2 40 A LL
Thread type
Series
Nil Rc
5 51-SY5000
F G
7 51-SY7000
N NPT
9 51-SY9000
T NPTF
Port size
Explosion-proof
Symbol Port size Applicable series
Intrinsically safe
51 explosion-proof Nil Without sub-plate
structure 1/4 51-SY5000
02
With sub-plate 51-SY7000
Type of actuation 3/8 51-SY7000
03
With sub-plate 51-SY9000
2-position single
1/2
04 51-SY9000
1 With sub-plate

Manual override
2-position double Nil: Non-locking push D: Push-turn locking E: Push-turn locking
type slotted type lever type
2

3-position closed center


Note)
3

3-position exhaust center

4 Note)
Lead wire length
3-position pressure center Symbol Lead wire length Note
3 300 mm —
5 Note) 6 600 mm Maximum length for L-type
10 1000 mm —
15 1500 mm —
Note) 3-position type is not
available for the 51- 20 2000 mm —
SY9000 series. 30 3000 mm —
Pilot type
100 10000 mm Semi-standard
Nil Internal pilot
R External pilot Electrical entry
Symbol Electrical entry
L-type plug connector
System Note 1) Note 2)
A Z728.H (51-SYE100-A) L
B MTL728P + (51-SYE100-B)
F KFD0-SD2-Ex1.1065 (51-SYE100-F)
Note 1) Attached barrier type L-type plug connector
The numbers in ( ), 51-SYE100-쏔 with cover
represents SMC’s control number. LL
Note 2) If the barrier is not necessary due to
valve replacement etc, enter O after the
system symbol.
Example) 51-SY5140-AOLL3 Terminal type

TT Note)

Note) The lead wire of TT-type is


connected to the terminal block.
14 B
Series 51-SY5000/7000/9000

Specifications

Series 51-SY5000 51-SY7000 51-SY9000


Fluid Air
Internal pilot 2-position single 0.15 to 0.7
operating pressure range 2-position double 0.1 to 0.7
(MPa) 3-position 0.2 to 0.7
External pilot Operating pressure range –100 kPa to 0.7
operating Pilot 2-position single 0.25 to 0.7
pressure range pressure 2-position double 0.25 to 0.7
(MPa) range 3-position 0.25 to 0.7
Ambient and fluid temperature (°C) –10 to 50 (No freezing)
Max. operating 2-position single, double 5
frequency (Hz) 3-position 3
Non-locking push type,
Manual override (Manual operation) Push-turn locking slotted type,
Push-turn locking lever type
Internal pilot Main/Pilot valve common exhaust
Pilot exhaust method
External pilot Pilot valve individual exhaust
Lubrication Not required
Mounting orientation Unrestricted
Impact/Vibration resistance (m/s2) Note) 150/30
Enclosure IP30 (L-type), IP40 (LL-type), IP65 (TT-type)
∗ Based on IEC60529
Note) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right
angles to the main valve and armature in both energized and de-energized states
every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was
performed at both energized and de-energized states in the axial direction and at
the right angles to the main valve and armature. (Values at the initial period)

Solenoid Specifications

L-type plug connector (L),


Electrical entry L-type plug connector with cover (LL),
Terminal type (TT)
Coil rated voltage 12 VDC
Allowable voltage fluctuation –10% to +10% of rated voltage
Coil insulation type Class B
Power consumption 0.52 W (at rated voltage)

Intrinsically Safe Explosion-proof System Specifications


Type of explosion-proof structure Intrinsically safe explosion-proof structure (ia) Note 1)
Applicable gas or ignition temperature
IIBT4
of steam and explosion class
Voltage to barrier 24 VDC (rated voltage of system) Note 2) Note 3)
Tolerant voltage fluctuation Refer to the barrier dimensions on page 41 and 42.
Note 1) Warning Can not be used in a class-0 environment. Use in a class-2 or class-1 environ-
ment.
Note 2) Caution The valve and barrier have polarity. If voltage is supplied with wrong polarity,
the barrier can not be used.
Note 3) Caution Voltage to the valve should be 10.8 VDC (minimum value).

Response Time
Note) Based on dynamic performance test, JIS B 8375-1981.
(Coil temperature: 20°C, system A, B, F at 24 VDC)

Response time (ms) (at 0.5 MPa)


Type of actuation
51-SY5000 51-SY7000 51-SY9000
2-position single 26 or less 38 or less 50 or less
2-position double 22 or less 30 or less 50 or less
3-position 38 or less 56 or less —

A 15
51-SY-B.qxd 09.3.18 11:11 AM Page 19

Base Mounted Series 51-SY5000/7000/9000

Flow-rate Characteristics
Series 51-SY5000
Flow-rate characteristics Note)
Valve model Type of actuation Port size 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB)
C(dm3/(s·bar)) b Cv C(dm3/(s·bar)) b Cv
2- Single
2.4 0.41 0.64 2.8 0.29 0.66
position Double
Closed center 1.8 0.47 0.50 1.8 0.40 0.47
51-SY540-
1/4 3.0 0.33 0.72
-02 3- Exhaust center 1.4 0.55 0.44
[1.2] [0.48] [0.37]
position
3.3 0.36 0.85
Pressure center 1.8 0.40 0.48
[0.84] [0.60] [0.28]
Note) [ ]: Normal position

Series 51-SY7000
Flow-rate characteristics Note)
Valve model Type of actuation Port size 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB)
C(dm3/(s·bar)) b Cv C(dm3/(s·bar)) b Cv
2- Single
4.1 0.41 1.1 4.1 0.29 1.0
position Double
Closed center 3.0 0.43 0.80 2.6 0.41 0.72
51-SY740-
1/4 4.7 0.35 1.1
-02 3- Exhaust center 2.6 0.42 0.71
[1.7] [0.48] [0.49]
position
5.3 0.39 1.3
Pressure center 2.2 0.49 0.63
[2.3] [0.49] [0.65]
2- Single
4.9 0.29 1.2 4.5 0.27 1.1
position Double
Closed center 3.0 0.40 0.80 2.6 0.45 0.73
51-SY740-
3/8 4.8 0.35 1.1
-03 3- Exhaust center 2.6 0.42 0.71
[1.7] [0.48] [0.49]
position
5.3 0.31 1.3
Pressure center 2.3 0.45 0.66
[2.3] [0.51] [0.64]
Note) [ ]: Normal position

Series 51-SY9000
Flow-rate characteristics
Valve model Type of actuation Port size 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB)
C(dm3/(s·bar)) b Cv C(dm3/(s·bar)) b Cv
51-SY940- 2- Single
3/8 7.9 0.34 2.0 9.6 0.43 2.6
-03 position Double
51-SY940- 2- Single
1/2 8.0 0.48 2.2 10 0.29 2.5
-04 position Double

16
51-SY-B.qxd 09.3.18 11:11 AM Page 20

Series 51-SY5000/7000/9000

Construction
Series SY
Symbol
2-position single 2-position single wr t q e

4 2
y
u (A) (B)
5 1 3
(EA) (P) (EB)

Symbol
2-position double 2-position double
wr t q

u 4
(A)
2
(B) y
5 1 3
(EA) (P) (EB)

Symbol
3-position closed center 3-position closed center/exhaust center/pressure center
wr t q

3-position exhaust center

4 2
u (A) (B)
y
5 1 3
3-position pressure center (EA) (P) (EB)

(This figure shows a closed center type.)

Component Parts
No. Description Material Note
1 Body Aluminum die-casted White
White
2 Adapter plate Resin
(51-SY9000: Gray)
3 End plate Resin White
4 Piston Resin —
5 Spool valve assembly Aluminum, HNBR —

Replacement Parts Caution


Part no.
No. Description Note Mounting screw
51-SY540 51-SY740 51-SY940
1/4: SY7000-27-1 ∗ 3/8: SY9000-27-1 ∗ tightening torques
6 Sub-plate SY5000-27-1 ∗ Aluminum die-casted
3/8: SY7000-27-2 ∗ 1/2: SY9000-27-2 ∗ M3: 0.8 N·m
7 Gasket SY5000-11-15 SY7000-11-11 SY9000-11-2 HNBR M4: 1.4 N·m
Round head SY9000-18-2 For valve mounting
— M3 x 26 M4 x 31
combination screw (M3 x 42) (Flat nickel plated)
∗ Thread type

17
51-SY-B.qxd 09.3.18 11:11 AM Page 21

Base Mounted Series 51-SY5000/7000/9000

Dimensions: 51-SY5000
2-position single
L-type plug connector (L)
18 19
51-SY5140(R)-L-02

9.5
37.2 2 x ø4.3 60.3

15.5 (For mounting) 48 8.3 M5 x 0.8 15.5

4
(External pilot port)
Insulator: Black (–) A B
17.5

35
B
A
Insulator: Red (+)
PE

X
EA P EB
Manual
17 override 56 4.3 17
65 62.5
M5 x 0.8
(Pilot EXH port) 109.1
<For external pilot type>

L (Lead wire length)

0.3 mm2
ø1.55

22
9.5
(E-type)

18 18
66.5

28 5 x 1/4"
(Piping port)

L-type plug connector with cover (LL)


51-SY5140(R)-LL-02
L (Lead wire length) 104

Insulator: Red (+)


Insulator: Black (–)

0.3 mm2
ø4.1

37.2

Terminal type (TT)


51-SY5140(R)-TT-02
Max.10
L (Lead wire length) 120.8

Lead wire marking


No.1 (+), No.2 (–)

0.75 mm2
ø5.9

34.5

18
51-SY-B.qxd 09.3.18 11:11 AM Page 22

Series 51-SY5000/7000/9000

Dimensions: 51-SY5000
2-position double 18 19
L-type plug connector (L)

9.5
51-SY5240(R)-L-02

37.2
15.5 48 4 15.5
2 x ø4.3
M5 x 0.8

4
(For mounting)
Insulator: Black (–) (External pilot port)
A B
17.5

17.5
B
A
PE

X
Insulator: Red (+) Manual EA P EB

override

35
17 17
56
M5 x 0.8 65.4 62.5
(Pilot EXH port) 153.6
<For external pilot type>

L (Lead wire length)


ø1.55

0.3 mm2
22
(E-type)

9.5

18 18
66.5

28 5 x 1/4"
(Piping port)

L-type plug connector with cover (LL)


51-SY5240(R)-LL-02
L (Lead wire length) 143.4
Insulator: Red (+)
Insulator: Black (–)

0.3 mm2
ø4.1

37.2

(71.7)

Terminal type (TT)


51-SY5240(R)-TT-02
Max.10
L (Lead wire length) 177

Lead wire marking


No.1 (+), No.2 (–)

0.75 mm2
ø5.9

34.5

(88.5)

19
51-SY-B.qxd 09.3.18 11:11 AM Page 23

Base Mounted Series 51-SY5000/7000/9000

Dimensions: 51-SY5000
3-position closed center/exhaust center/pressure center
L-type plug connector (L)
3 18 19
51-SY5 45 40(R)-L-02

9.5
37.2
15.5 48 4 15.5
2 x ø4.3 M5 x 0.8
(For mounting)

4
Insulator: Black (–) (External pilot port)
A B
17.5

17.5
A

B
PE

X
Insulator: Red (+) Manual
EA P EB

35
17 override 17
56
M5 x 0.8 78 44.1 62.5
(Pilot EXH port)
166.2
<For external pilot type>

L (Lead wire length)


ø1.55

0.3 mm2
22
9.5
(E-type)

18 18
66.5

28
89.4

5 x 1/4" (Piping port)

L-type plug connector with cover (LL)


3
51-SY5 45 40(R)-LL-02
L (Lead wire length) 156
Insulator: Red (+)
Insulator: Black (–)

0.3 mm2
ø4.1

37.2

84.3

Terminal type (TT)


3
51-SY5 45 40(R)-TT-02
Max.10
L (Lead wire length) 189.6

Lead wire marking


No.1 (+), No.2 (–)

0.75 mm2
ø5.9

34.5

101.1

20
51-SY-B.qxd 09.3.18 11:11 AM Page 24

Series 51-SY5000/7000/9000

Dimensions: 51-SY7000
2-position single
L-type plug connector (L)
21 22.5
03 

13.5
51-SY7140(R)-L- 02

79.2
41.7 61 10.4
21.5 2 x ø4.3 M5 x 0.8 21
(For mounting)

4
(External pilot port)
Insulator: Black (–) A B
23

PE

38
46
A

X
Insulator: Red (+) Manual EA P EB
override
21 69 6.4 21.5
123.3 67.2
M5 x 0.8
(Pilot EXH port)
<For external pilot type>
71.2 (E-type)

L (Lead wire length)


ø1.55

0.3 mm2
26.5
11.5
13.5

20.5 20.5
5 x 3/8", 1/4"
33
(Piping port)

L-type plug connector with cover (LL)


03 
51-SY7140(R)-LL- 02
L (Lead wire length) 118.2

Insulator: Red (+)


Insulator: Black (–)

0.3 mm2
ø4.1

41.7

Terminal type (TT)


03 
51-SY7140(R)-TT- 02 Max.10
L (Lead wire length) 135

Lead wire marking


No.1 (+), No.2 (–)

0.75 mm2
ø5.9

39

21
51-SY-B.qxd 09.3.18 11:11 AM Page 25

Base Mounted Series 51-SY5000/7000/9000

Dimensions: 51-SY7000
2-position double 21 22.5
L-type plug connector (L)

13.5
03 
51-SY7240(R)-L- 02

41.7 61 4
2 x ø4.3
21.5 21
(For mounting) M5 x 0.8

4
Insulator: Black (–) (External pilot port)
A B
23

23
PE

B
A

X
Insulator: Red (+)
Manual EA P EB

override

38
46
21 69 21.5
79.6 67.2
M5 x 0.8
167.8
(Pilot EXH port)
<For external pilot type>

L (Lead wire length)

0.3 mm2
ø1.55

26.5
13.5
11.5
(E-type)

20.5 20.5
71.2

33

5 x 3/8", 1/4" (Piping port)

L-type plug connector with cover (LL)


03 
51-SY7240(R)-LL- 02
L (Lead wire length) 157.6
Insulator: Red (+)
Insulator: Black (–)

0.3 mm2
ø4.1

41.7

(78.8)

Terminal type (TT)


03 
51-SY7240(R)-TT- 02
Max.10
L (Lead wire length) 191.2

Lead wire marking


No.1 (+), No.2 (–)

0.75 mm2
ø5.9

39

(95.6)

22
51-SY-B.qxd 09.3.18 11:11 AM Page 26

Series 51-SY5000/7000/9000

Dimensions: 51-SY7000
3-position closed center/exhaust center/pressure center
L-type plug connector (L) 21 22.5

13.5
3
51-SY7 40(R)-L- 
4
5
02
03

61 4
41.7
2 x ø4.3 M5 x 0.8
21.5 21
(For mounting) (External pilot port)

4
Insulator: Black (–) A B
23

23
PE

B
A

X
Insulator: Red (+)
Manual EA P EB

override

46
38
21 69 21.5
92.6 44.1 67.2
M5 x 0.8 180.8
(Pilot EXH port)
<For external pilot type>

L (Lead wire length)


ø1.55

0.3 mm2
26.5
13.5
11.5
(E-type)

20.5 20.5
71.2

33
96.9

5 x 3/8", 1/4" (Piping port)

L-type plug connector with cover (LL)


3
03 
51-SY7 45 40(R)-LL- 02
L (Lead wire length) 170.6
Insulator: Red (+)
Insulator: Black (–)

0.3 mm2
ø4.1

41.7

91.8

Terminal type (TT)


3
03
51-SY7 45 40(R)-TT- 02
Max.10
L (Lead wire length) 204.2

Lead wire marking


No.1 (+), No.2 (–)

0.75 mm2
ø5.9

39

108.6

23
51-SY-B.qxd 09.3.18 11:11 AM Page 27

Base Mounted Series 51-SY5000/7000/9000

Dimensions: 51-SY9000
2-position single
L-type plug connector (L) 29 30

17.5
04 
51-SY9140-L- 03

109.3
51.2 86.5 16.8
25 2 x ø5.4 27
(For mounting) 1/8"

5
(External pilot port)
Insulator: Black (–) 4 A 2 B
28.5

PE

47
57
A

B
Insulator: Red (+)

X
5 EA 1 P 3 EB

27 96.5 11.8 25
153.4 76.5
1/8"
(Pilot EXH port)
<For external pilot type>
L (Lead wire length)

0.3 mm2
ø1.55

34.5
15.5
17.5
(E-type)

29.5 29.5
80.5

44.5

5 x 3/8", 1/2" (Piping port)

L-type plug connector with cover (LL)


04 
51-SY9140-LL- 03
L (Lead wire length) 148.3

Insulator: Red (+)


Insulator: Black (–)

0.3 mm2
ø4.1

51.2

Terminal type (TT)


04 
51-SY9140-TT- 03
Max.10
L (Lead wire length) 165.1

Lead wire marking


No.1 (+), No.2 (–)

0.75 mm2
ø5.9

48.5

24
51-SY-B.qxd 09.3.18 11:11 AM Page 28

Series 51-SY5000/7000/9000

Dimensions: 51-SY9000
2-position double 29 30

17.5
L-type plug connector (L)
04
51-SY9240-L- 03

106
86.5
51.2
25 2 x ø5.4
27
(For mounting) 1/8"

5
(External pilot port)
Insulator: Black (–) 4 A 2 B
28.5

PE

B
Insulator: Red (+)

X
5 EA 1 P 3 EB

47
57
27 96.5 25
194.2 76.5
1/8"
(Pilot EXH port)
<For external pilot type>
L (Lead wire length)

0.3 mm2
ø1.55

34.5
(E-type)

15.5
17.5

29.5 29.5
80.5

44.5

5 x 3/8", 1/2" (Piping port)

L-type plug connector with cover (LL)


04 
51-SY9240-LL- 03
L (Lead wire length) 184

Insulator: Red (+)


Insulator: Black (–)

0.3 mm2
ø4.1

51.2

(92)

Terminal type (TT)


04
51-SY9240-TT- 03
Max.10
L (Lead wire length) 217.6

Lead wire marking


No.1 (+), No.2 (–)

0.75 mm2
ø5.9

48.5

(108.8)

25
51-SY-B.qxd 09.3.18 11:11 AM Page 29

26
51-SY-B.qxd 09.3.18 11:11 AM Page 30

Intrinsically Safe Explosion-proof System


5 Port Solenoid Valve
Series 51-SY5000/7000
Body Ported Manifold
Type 20 Bar Stock Type
How to Order Manifold How to Order Valve Manifold Assembly

51 SS5Y 5 20 05 Example Double solenoid


51-SY5220-ALL3-01 (2 sets)
Cylinder port size Single solenoid
01: 1/8" 51-SY5120-ALL3-01 (2 sets)
Explosion-proof
Intrinsically safe
51 explosion-proof Blanking plate assembly
structure SY5000-26-20A (1 set)

Manifold base (5 stations)


Manifold series 51-SS5Y5-20-05
5 51-SY5000
7 51-SY7000 Sta
tio
ns
····
·3
Stations 2
1
02 2 stations
51-SS5Y5-20-05 ·········· 1 set (Type 20, 5 station manifold base part no.)
∗ SY5000-26-20A ··········· 1 set (Blanking plate assembly part no.)
20 20 stations ∗ 51-SY5120-ALL3-01 ····· 2 sets (Single solenoid part no., barrier is attached)
∗ This also includes the ∗ 51-SY5220-ALL3-01 ····· 2 sets (Double solenoid part no., barrier is attached)
number of blanking The asterisk denotes the symbol for assembly.
plate assemblies. Prefix it to the part nos. of the solenoid valve, etc.
Add the valve and option part number under the manifold base part number.
In the case of complex arrangement, specify them on the manifold
Thread type specification sheet.
Nil Rc
00F G
00N NPT
00T NPTF

27
Body Ported Series 51-SY5000/7000

How to Order Valve

51 SY 5 1 20 A LL 3 01
Explosion-proof
Thread type
Intrinsically safe
51 explosion-proof Nil Rc
structure F G
Series N NPT
5 51-SY5000 T NPTF
7 51-SY7000

A, B port size
Type of actuation Thread piping
1 2-position single Symbol Port size Applicable series
2 2-position double 01 1/8 51-SY5000
3 3-position closed center 02 1/4 51-SY7000
4 3-position exhaust center
One-touch fitting
5 3-position pressure center
Symbol Port size Applicable series
C4 ø4 one-touch fitting
System Note 1) Note 2) C6 ø6 one-touch fitting 51-SY5000
A Z728.H (51-SYE100-A) C8 ø8 one-touch fitting
B MTL728P + (51-SYE100-B) C8 ø8 one-touch fitting
51-SY7000
F KFD0-SD2-Ex1.1065 (51-SYE100-F) C10 ø10 one-touch fitting
Note 1) Attached barrier type Warning If a resin tube is used, take measures
The numbers in ( ), 51-SYE100-쏔 against static electricity.
represents SMC’s control number.
Note 2) If the barrier is not necessary due to
valve replacement etc, enter O after the
system symbol.
Manual override
Example) 51-SY5120-AOLL3-01 Nil Non-locking push type
D Push-turn locking slotted type
E Push-turn locking lever type

Electrical entry
Symbol Electrical entry Lead wire length
Symbol Lead wire length Note
L-type plug connector
3 300 mm —
L 6 600 mm Maximum length 600 mm for L-type
10 1000 mm —
15 1500 mm —
20 2000 mm —
L-type plug connector
with cover 30 3000 mm —
LL 100 10000 mm Semi-standard

Terminal type

TT Note)

Note) The lead wire of TT-type is


connected to the terminal block.

Note) When placing an order for body ported


solenoid valve as a single unit, mounting
screws and a gasket for manifold are not
attached. Order them separately, if
necessary. (For details, refer to page 32.)

28 B
51-SY-B.qxd 09.3.18 11:11 AM Page 32

Series 51-SY5000/7000

Manifold Specifications

Model 51-SS5Y5-20 51-SS5Y7-20


Applicable valve 51-SY520 51-SY720
Manifold type Single base B mount
P (SUP)/R (EXH) Common SUP/EXH
Valve stations 2 to 20 stations Note 1)
A, B port location Valve
P, EA, EB port 1/4
1/8
Port size 1/4
C4 (ø4 one-touch fitting)
A, B port C8 (ø8 one-touch fitting)
C6 (ø6 one-touch fitting)
C10 (ø10 one-touch fitting)
C8 (ø8 one-touch fitting)
Manifold base mass W (g)
W = 36n + 64 W = 43n + 64
n: Stations
Note 1) For 10 stations or more (5 stations or more for the 51-SS5Y7), supply pressure to P port
on both sides and exhaust from EA/EB port on both sides.
Note 2) Refer to “Manifold Options” on page 32.

Warning If a resin tube is used, take measures against static electricity.

Flow-rate Characteristics

Port size Flow-rate characteristics


Model 1, 5, 3 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB)
(P, EA, EB) (A, B) C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b Cv
51-SS5Y5-20 1/4 C8 1.9 0.28 0.48 2.2 0.20 0.53
51-SS5Y7-20 1/4 C10 3.6 0.31 0.93 3.6 0.27 0.88
Note) The value is for manifold base with 5 stations and individually operated 2-position type.

29
51-SY-B.qxd 09.3.18 11:11 AM Page 33

Body Ported Series 51-SY5000/7000

Dimensions: 51-SY5000
L-type plug connector (L)
51-SS5Y5-20- Stations -
L1 71 (E-type)

L2 10 59.5
Manual override {1/8"}

16.5

11.5
4 x ø4.5
(Mounting hole)
45.3

EB
EB

B
B
32.7

32.3

30
166.2

21
153.6

60
P
P

21
32.7

16.2

20
EA
EA

A
A

76.8
6 x 1/4"
{P(1), EA(5), EB(3) port}

(Pitch) 1/8"
P = 16 22 {A(4), B(2) port}
(Lead wire length)

n 2 1 Stations
L

67
41.7

36.2
26.5

L-type plug connector with cover (LL) Terminal type (TT)


51-SS5Y5-20- Stations - 51-SS5Y5-20- Stations -
189.6
156
143.4

177
71.7

88.5
Max.10
L (Lead wire length)

L (Lead wire length)

41.7
67 39
67

Stations n 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations 10 stations 11 stations 12 stations 13 stations 14 stations 15 stations 16 stations 17 stations 18 stations 19 stations 20 stations
L1 60 76 92 108 124 140 156 172 188 204 220 236 252 268 284 300 316 332 348
L2 40 56 72 88 104 120 136 152 168 184 200 216 232 248 264 280 296 312 328
30
51-SY-B.qxd 09.3.18 11:11 AM Page 34

Series 51-SY5000/7000

Dimensions: 51-SY7000
L-type plug connector (L)
51-SS5Y7-20- Stations -
71 (E-type)
L1
67
L2 10
Manual override {1/4"}

4 x ø4.5 16.5
(Mounting 11.5
hole)
52.8

39.4
EB
EB

30
180.8

21
167.8

60
P
P

21
39.8

21 (For mounting)
EA
EA

83.9

6 x 1/4"
(A, B port)

{P(1), EA(5), EB(3) port}


20

(Pitch) 1/4"
P = 19 23.5 {A(4), B(2) port}
L (Lead wire length)

n 2 1 Stations
67
41.7

38.3
26.5

L-type plug connector with cover (LL) Terminal type (TT)


51-SS5Y7-20- Stations - 51-SS5Y7-20- Stations -
204.2
191.2
170.6
157.6

95.6
71.7

Max.10
L (Lead wire
length)

L (Lead wire length)

39
41.7
67
67

Stations n 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations 10 stations 11 stations 12 stations 13 stations 14 stations 15 stations 16 stations 17 stations 18 stations 19 stations 20 stations
L1 66 85 104 123 142 161 180 199 218 237 256 275 294 313 332 351 370 389 408
L2 46 65 84 103 122 141 160 179 198 217 236 255 274 293 312 331 350 369 388
31
51-SY-B.qxd 09.3.18 11:11 AM Page 35

Body Ported Series 51-SY5000/7000

Manifold Options
 Type 20  Gasket Assembly Part No.  Individual SUP Spacer
Blanking Plate Assembly Round head
combination screw
Assembly

t
Gasket

SUP port
Series Assembly part no. Series Gasket assembly
51-SY5000 SY5000-26-20A 51-SY5000 SY5000-GS-1
51-SY7000 SY7000-26-22A 51-SY7000 SY7000-GS-1
Note) Gasket assembly
consists of 10 sets of
mounting screws and a Series Assembly part no. Port size t
gasket. 51-SY5000 SY5000-38-1∗A 1/8 15
51-SY7000 SY7000-38-1∗A 1/4 18
Note) The SUP port of the 51-SY5000/7000
may be either on the lead wire side or
on the end plate side. (An assembly
is shipped under the conditions
 Individual EXH Spacer  Individual SUP Spacer Assembly shown in the figure.)
Assembly + Individual EXH Spacer Assembly
(Double spacer)

EXH port
(Both sides)

Individual SUP + Port Applicable


5
E5
Series Individual EXH size manifold type
assembly part no.
EXH port
Series Assembly part no. Port size t (Both sides) 51-SY5000 SY5000-75-2∗A 1/8
Type 20
51-SY5000 SY5000-39-1∗A 1/8 15 P1
51-SY7000 SY7000-73-3∗A 1/4
1

51-SY7000 SY7000-39-1∗A 1/4 18 SUP port Note) The SUP spacer's port does not have an orientation.
As for the EXH ports, adjust the symbol “5” to the pilot
valve side. Also, please make sure to connect the
individual ports to protect the wiring section of the pilot
valve from drainage, etc.
The individual SUP spacer and EXH spacer can be
mounted either on the upper side or lower side. (The
above illustration shows the condition when the

∗ Thread type
product is shipped out from a factory already
Caution assembled.)
Mounting screw Nil Rc
tightening torques F G
M3: 0.8 N· m N NPT
M4: 1.4 N· m T NPTF

Warning
When mounting a valve or spacer on the
manifold base or sub-plate, etc., those
mounting directions are determined. If
mounted in the wrong direction, the equipment
to be connected may cause malfunction. Refer
to external dimensions, and then mount it.

32
51-SY-B.qxd 09.3.18 11:11 AM Page 36

Intrinsically Safe Explosion-proof System


5 Port Solenoid Valve
Type 41 Series 51-SY5000/7000
Base Mounted Manifold
Type 42 Bar Stock Type
How to Order Manifold How to Order Valve Manifold Assembly
Type 41/Compact Type
Example
51 SS5Y 5 41 05 01 Single solenoid
51-SY5140-ALL3 (2 sets)
Explosion-proof
1
Intrinsically safe Double solenoid 2
51 explosion-proof 51-SY5240-ALL3 (2 sets) 3
structure
Stations
02 2 stations
Blanking plate assembly
Manifold series Sta
tio
SY5000-26-20A (1 set) ns
5 51-SY5000 20 20 stations
∗ This also includes the
number of blanking
plate assemblies.

A, B port size Thread type


Thread piping Nil Rc EA
Symbol Port size Applicable series F G P
N NPT EB
01 1/8 51-SY5000 A
T NPTF B
One-touch fitting (Metric size)
A, B port size
Symbol Port size Applicable series Manifold base (5 stations)
01: 1/8
C6 ø6 one-touch fitting 51-SS5Y5-41-05-01
51-SY5000
C8 ø8 one-touch fitting
51-SS5Y5-41-05-01 ····· 1 set (Type 41, 5 station manifold base part no.)
One-touch fitting (Inch size) ∗ 51-SY5240-ALL3 ········ 2 sets (Double solenoid part no., barrier is attached)
Symbol Port size Applicable series ∗ 51-SY5140-ALL3 ········ 2 sets (Single solenoid part no., barrier is attached)
N7 ø1/4" one-touch fitting ∗ SY5000-26-20A ·········· 1 set (Blanking plate assembly part no.)
51-SY5000 The asterisk denotes the symbol for assembly.
N9 ø5/16" one-touch fitting
Prefix it to the part nos. of the solenoid valve, etc.
Add the valve and option part number under the manifold base part number.
In the case of complex arrangement, specify them on the manifold
Type 42/External Pilot Capable specification sheet.

51 SS5Y 5 42 05 02
Explosion-proof
Intrinsically safe Stations
51 explosion-proof 02 2 stations
structure

Manifold series 20 20 stations


5 51-SY5000

A, B port size Thread type


Thread piping Nil Rc
Symbol Port size Applicable series F G
51-SY5000 N NPT
02 1/4
51-SY7000 T NPTF

One-touch fitting (Metric size) Warning If a resin tube is used, take


measures against static
Symbol Port size Applicable series electricity.
C6 ø6 one-touch fitting
51-SY5000
C8 ø8 one-touch fitting
C10 ø10 one-touch fitting 51-SY7000
One-touch fitting (Inch size)
Symbol Port size Applicable series
N7 ø1/4" one-touch fitting
51-SY5000
N9 ø5/16" one-touch fitting
N11 ø3/8" one-touch fitting 51-SY7000

33
Base Mounted Series 51-SY5000/7000

How to Order Valve

51 SY 5 2 40 A LL 3
Explosion-proof
Manual override
Intrinsically safe
51 explosion-proof Nil Non-locking push type
structure D Push-turn locking slotted type
Series E Push-turn locking lever type
5 51-SY5000
7 51-SY7000
Lead wire length
Symbol Lead wire length Note
Type of actuation 3 300 mm —
1 2-position single 6 600 mm Maximum length 600 mm for L-type
2 2-position double 10 1000 mm —
3 3-position closed center 15 1500 mm —
4 3-position exhaust center 20 2000 mm —
5 3-position pressure center 30 3000 mm —
100 10000 mm Semi-standard

Pilot type
Nil Internal pilot Electrical entry
R External pilot Symbol Electrical entry
L-type plug connector

System Note 1) Note 2) L


A Z728.H (51-SYE100-A)
B MTL728P + (51-SYE100-B)
F KFD0-SD2-Ex1.1065 (51-SYE100-F) L-type plug connector
Note 1) Attached barrier type with cover
The numbers in ( ), 51-SYE100-쏔 LL
represents SMC’s control number.
Note 2) If the barrier is not necessary due to
valve replacement etc, enter O after the
system symbol. Terminal type
Example) 51-SY5140-AOLL3
TT Note)

Note) The lead wire of TT-type is


connected to the terminal block.

34 B
51-SY-B.qxd 09.3.18 11:11 AM Page 38

Series 51-SY5000/7000

Manifold Specifications

Model 51-SS5Y5-41 51-SS5Y5-42 51-SS5Y7-42


Applicable valve 51-SY540 51-SY740
Manifold type Single base B mount
P (SUP)/R (EXH) Common SUP/EXH
Valve stations 2 to 20 stations Note 1)

A, B port Location Base


location Direction Side
P, EA, EB port 1/4
1/8 1/4
Port size C6 (ø6 one-touch C6 (ø6 one-touch 1/4
A, B port fitting) fitting) C10 (ø10 one-
C8 (ø8 one-touch C8 (ø8 one-touch touch fitting)
fitting) fitting)

Manifold base mass W (g)


W =61n + 101 W =79n + 127 W =100n + 151
n: Stations

Note 1) For 10 stations or more (5 stations or more for the 51-SS5Y7), supply pressure to P port
on both sides and exhaust from EA/EB port on both sides.
Note 2) Refer to “Manifold Options” on page 39.

Flow-rate Characteristics

Port size Flow-rate characteristics


Model 1, 5, 3 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→EA/EB)
(P, EA, EB) (A, B) C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b Cv
51-SS5Y5-41 1/4 C8 1.8 0.23 0.44 1.9 0.16 0.45
51-SS5Y5-42 1/4 C8 1.9 0.20 0.46 1.9 0.12 0.43
51-SS5Y7-42 1/4 C10 3.0 0.25 0.75 3.0 0.12 0.66
Note) The value is for manifold base with 5 stations and individually operated 2-position type.

35
51-SY-B.qxd 09.3.18 11:11 AM Page 39

Base Mounted Series 51-SY5000/7000

Dimensions: 51-SY5000
L-type plug connector (L)
51-SS5Y5-41- Stations - L1
5.5 L2 77.5 (E-type)

L (Lead wire length) 15.2

Manual 13.8
override

4 x ø4.5
(Mounting

113.6
hole) A A A A

20
20

65

66.8
166.2

20
37.8
27.8

B B B B

4.5
6 x 1/4"
8.5

40
52.6

{P(1), EA(5), EB(3) port}

(Pitch)
18 P = 16

Stations 1 2 n
73.5

48.2

42.7
33
23
7.5

9 2n x 1/8"
(Pitch) {A(4), B(2) port}
15.5 P = 16

L-type plug connector with cover (LL) Terminal type (TT)


51-SS5Y5-41- Stations - 51-SS5Y5-41- Stations -
125.3

189.6
113.6
156

51.7
64.3
40

Max.10
L (Lead wire length)
L (Lead wire length)

48.2
45.5
73.5
73.5

Stations n 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations 10 stations 11 stations 12 stations 13 stations 14 stations 15 stations 16 stations 17 stations 18 stations 19 stations 20 stations
L1 52.5 68.5 84.5 100.5 116.5 132.5 148.5 164.5 180.5 196.5 212.5 228.5 244.5 260.5 276.5 292.5 308.5 324.5 340.5
L2 42 58 74 90 106 122 138 154 170 186 202 218 234 250 266 282 298 314 330
36
51-SY-B.qxd 09.3.18 11:11 AM Page 40

Series 51-SY5000/7000

Dimensions: 51-SY5000
L-type plug connector (L)
51-SS5Y5-42- Stations - 82.3 (E-type)

length)
(Lead
wire
L
M5 x 0.8
(Pilot EXH port)
Manual override <When using external pilot
solenoid valve>
17.6

109.7
A A A A

24
20
65.4
20

68
156

23.6
20

39
B B B B
29

5.3
6 x 1/4"

33.7
7.3
46.3

{P(1), EA(5), EB(3) port}

M5 x 0.8
(External pilot port)
(Pitch)
21 P = 17.5
5 L2
L1
Stations 1 2 n

47.5
53

37.8
27.3
9.8

8.5 2n x 1/4"
(Pitch) {A(4), B(2) port}
19 P = 17.5

L (Lead wire length)


L-type plug connector with cover (LL) Terminal type (TT)
L (Lead wire length)

82.3 (E-type)
51-SS5Y5-42- Stations - 51-SS5Y5-42- Stations -
82.3 (E-type) 50.3
53
Max.10
109.7
109.7

189.6
156
F

33.7

50.5
46.3

63.1

Stations n 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9stations 10 stations 11 stations 12 stations 13 stations 14 stations 15 stations 16 stations 17 stations 18 stations 19 stations 20 stations
L1 59.5 77 94.5 112 129.5 147 164.5 182 199.5 217 234.5 252 269.5 287 304.5 322 339.5 357 374.5
L2 49.5 67 84.5 102 119.5 137 154.5 172 189.5 207 224.5 242 259.5 277 294.5 312 329.5 347 364.5
37
51-SY-B.qxd 09.3.18 11:11 AM Page 41

Base Mounted Series 51-SY5000/7000

Dimensions: 51-SY7000
L-type plug connector (L)
51-SS5Y7-42- Stations - L1
85.5 (E-type)
6 L2
37
length)
(Lead
wire
19.1
L

Manual M5 x 0.8
override (Pilot EXH port)
<When using external pilot
solenoid valve>
4 x ø4.5
(Mounting

125.6

EA
hole) A A A A

PE

26
21
79.6
21
180.8

73
26.6
21

42
EB
31.5

X
B B B B

6 x 1/4"
1.9
11.1

42.2
{P(1), EA(5), EB(3) port}
55.2

M5 x 0.8
(External pilot port)
(Pitch)
21 P = 19

Stations 1 2 n
81.5
56.2

52.8

A A
9.4

41
28.9

B B

7 2n x 1/4"
(Pitch)
24 P = 19 {A(4), B(2) port}
L (Lead wire length)

L (Lead wire length)


L-type plug connector with cover (LL) Terminal type (TT)
51-SS5Y7-42- Stations - 81.5 51-SS5Y7-42- Stations - 81.5
56.2 53.5
Max.10
137.3
120.5
EA
PE

EA
PE
170.6
P

204.2
P
EB
X

EB
X
37.1

50.1

53.9
66.9

Stations n 2 stations 3 stations 4 stations 5 stations 6 stations 7 stations 8 stations 9 stations 10 stations 11 stations 12 stations 13 stations 14 stations 15 stations 16 stations 17 stations 18 stations 19 stations 20 stations
L1 61 80 99 118 137 156 175 194 213 232 251 270 289 308 327 346 365 384 403
L2 49 68 87 106 125 144 163 182 201 220 239 258 277 296 315 334 353 372 391
38
51-SY-B.qxd 09.3.18 11:11 AM Page 42

Series 51-SY5000/7000

Manifold Options
 Type 41, 42  Gasket Assembly Part No.  Individual SUP Spacer
Blanking Plate Assembly Round head Assembly
combination screw

t
Gasket

Series Assembly part no. Series Gasket assembly


SUP port
51-SY5000 SY5000-26-20A 51-SY5000 SY5000-GS-2
51-SY7000 SY7000-26-22A 51-SY7000 SY7000-GS-2
Note) Gasket assembly
consists of 10 sets of
Series Assembly part no. Port size t
mounting screws and a
gasket. 51-SY5000 SY5000-38-16∗A 1/8 15
51-SY7000 SY7000-38-16∗A 1/4 18
Note) The SUP port of the 51-SY5000/7000
may be either on the lead wire side or
on the end plate side. (An assembly
is shipped under the conditions
 Individual EXH Spacer  Individual SUP Spacer Assembly shown in the figure.)

Assembly + Individual EXH Spacer Assembly


(Double spacer)

t
Individual SUP +
Series Individual EXH Port size
EXH port
assembly part no.
51-SY5000 SY5000-75-1∗A 1/8
E
5

51-SY7000 SY7000-73-1∗A 1/4


EXH port
Note) The port on a spacer can be directed to
Series Assembly part no. Port size t the pilot valve side or end plate side. For
51-SY5000 SY5000-39-16∗A 1/8 15 P

1
mounting the port to the pilot valve side,
SUP port please make sure to connect the ports to
51-SY7000 SY7000-39-16∗A 1/4 18
protect the pilot valve wiring section from
drainage.
The individual SUP spacer and EXH
spacer can be mounted either on the
upper side or lower side. (The above
illustration shows the condition when the
product is shipped out from a factory

Caution ∗ Thread type  Plug (White) already assembled.)

Mounting screw Nil Rc These are inserted in unused cylinder ports and SUP, EXH ports.
Purchasing order is available in units of 10 pieces.
tightening torques F G
M3: 0.8 N· m N NPT Dimensions
øD

ød

M4: 1.4 N· m T NPTF Applicable fittings size ød Model A L D


A 6 KQ2P-06 18 35 8
Warning L
8 KQ2P-08 20.5 39 10

When mounting a valve or spacer on the


10 KQ2P-10 22 43 12
manifold base or sub-plate, etc., those 1/4" KQ2P-07 18 35 8.5
mounting directions are determined. If 5/16" KQ2P-09 20.5 39 10
mounted in the wrong direction, the equipment 3/8" KQ2P-11 22 43 11.5
to be connected may cause malfunction. Refer
to external dimensions, and then mount it.

39
51-SY-B.qxd 09.3.18 11:11 AM Page 43

Base Mounted Series 51-SY5000/7000

Manifold Options
 How to Order Interface Regulator

Series 51-SY5000
ARBY5000-00--2 ARBY5000-M1--2
ARBY5000 00 P 2
Pressure gauge
connection port
00 Pressure gauge (G15-10-01)
M1 Plug (M-5P)

Regulating port
P P port
A1 A port (P controlled, A regulated)
B1 B port (P controlled, B regulated)

Series 51-SY7000
ARBY7000-00--2 ARBY7000-M1--2
ARBY7000 00 P 2
Pressure gauge
connection port
00 Pressure gauge (G15-10-01)
M1 Plug (M-5P)

Regulating port
P P port
A1 A port (P controlled, A regulated)
B1 B port (P controlled, B regulated)

Accessory
Series Round head combination screw Gasket
ARBY5000 M3 x 48.5 (Flat nickel plated) SX5000-57-6
ARBY7000 M4 x 57 (Flat nickel plated) SX7000-57-4

Caution
Mounting screw
tightening torques
M3: 0.8 N·m
M4: 1.4 N·m

40
Series 51-SY
Zener Diode Barrier Dimensions
Terminal No. indication (Non-hazardous side)
51-SYE100-A Terminal No. indication (Hazardous side) Terminal No.8: +
Barrier input: 24 VDC ±10%
Terminal No.1: + Terminal No.7: –
Terminal No.2: –
Terminal for ground (2 parts)

Z728.H
1 2
3 4

5 6
7 8
(M3 Round head combination screw)

12.5
115
Examination certificate emblem
(Examination certificate No. TC14452)

Safe R
Barrier

Terminal: No.2 Terminal: No.1 Terminal: No.7 Terminal: No.8


110

Safe Area/
1 8
Nicht
Hazardous
>PC<

Ex-Bereich
Area/
Ex-Berelch X3 Unspecified
equipment
2 7 V 250V

Manufacturer: Pepperl+Fuchs
Note) See P+F’s catalog for options.

DIN rail mountable (width: 35 mm, recommended thickness: 1.2 mm)

Caution
Terminal No. 2, No. 7 and the DIN rail mounting bracket on the bottom part of
the barrier or terminal for grounding are short circuit connected.

240 Ω Fuse
1 8

2 7
Zener diode

Internal circuit diagram

51-SYE100-B Terminal No. indication (Non-hazardous side)


Terminal No. indication (Hazardous side) Terminal No.1: + +2
Terminal No.3: + Barrier input: 24 VDC –10%
Terminal No.2: –
Terminal No.4: – (21.6 to 24.5 VDC)

Terminal: No.3 Terminal: No.1


3

1
Hazardous
area tmnls

728P+
4

Terminal: No.4 Terminal: No.2


25 7.5

7.5 11.5

Terminal for ground (with M nut)


(Terminal for earth bus bar mounting)
728P+
2 1

MTL 728P+Shunt-diode safety barrier


61.5

3 1
49.2

Haz Safe

4 2

85 14.2
Manufacturer: Measurement Technology
93.5 Ltd.
Examination certificate emblem Note) See MTL Instruments' catalog for
(Examination certificate No. TC14453) options.

A 41
Series 51-SY
Insulating Barrier Dimensions
51-SYE100-F
100
93

Terminal: No.7 Terminal: No.8

Terminal: No.2 Terminal: No.1


115

Examination
certificate emblem
+ 7
(Examination certificate
1
I
– U
2

3

8
No. TC19711)

>PC<
DIN rail mounted part 20
(width: 35 mm)

LED: Orange (Power supply input indication)


Manufacturer: Pepperl+Fuchs
Terminal section Terminal section
KFD0-SD2-Ex1.1065

Note) See P+F's catalog for options.


10 11 12
3

7 8 9
6
2
5

removable removable
OUT
4
1

Terminal No. indication (Hazardous side) Terminal No. indication (Non-hazardous side)
Terminal: No.1: + Terminal: No.7: +
Barrier input: 24 VDC ±10%
Terminal: No.2: – Terminal: No.8: –

42 B
51-SY-B.qxd 09.3.18 11:11 AM Page 46

Safety Instructions
These safety instructions are intended to prevent hazardous situations and/or equipment damage.
These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or
“Danger.” They are all important notes for safety and must be followed in addition to International
Standards (ISO/IEC)∗1), and other safety regulations.
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
ISO 4413: Hydraulic fluid power – General rules relating to systems.
IEC 60204-1: Safety of machinery – Electrical equipment of machines. (Part 1: General requirements)
ISO 10218-1: Manipulating industrial robots - Safety.
etc.

Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or
Caution: moderate injury.
Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or
Warning: serious injury.
Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious
Danger : injury.

Warning
1. The compatibility of the product is the responsibility of the person who designs the equipment
or decides its specifications.
Since the product specified here is used under various operating conditions, its compatibility with specific equipment must
be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test
results. The expected performance and safety assurance of the equipment will be the responsibility of the person who
has determined its compatibility with the product. This person should also continuously review all specifications of the
product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment
failure when configuring the equipment.
2. Only personnel with appropriate training should operate machinery and equipment.
The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of
machines or equipment including our products must be performed by an operator who is appropriately trained and
experienced.
3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.
1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling
or runaway of the driven objects have been confirmed.
2. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the
power from any appropriate source is cut, and read and understand the specific product precautions of all relevant
products carefully.
3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of safety measures if the product is to
be used in any of the following conditions.
1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct
sunlight.
2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military,
medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop
circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the
standard specifications described in the product catalog.
3. An application which could have negative effects on people, property, or animals requiring special safety analysis.
4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical
protective function, and periodical checks to confirm proper operation.

Back page 1
51-SY-B.qxd 09.3.18 11:11 AM Page 47

Safety Instructions
Caution
1. The product is provided for use in manufacturing industries.
The product herein described is basically provided for peaceful use in manufacturing industries.
If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract
if necessary.
If anything is unclear, contact your nearest sales branch.

Limited warranty and Disclaimer/Compliance Requirements


The product used is subject to the following “Limited warranty and Disclaimer” and “Compliance Requirements”.
Read and accept them before using the product.

Limited warranty and Disclaimer


1. The warranty period of the product is 1 year in service or 1.5 years after the product is delivered.∗2)
Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest
sales branch.
2. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product
or necessary parts will be provided.
This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure
of the product.
3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified
catalog for the particular products.
∗2) Vacuum pads are excluded from this 1 year warranty.
A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of
rubber material are not covered by the limited warranty.

Compliance Requirements
1. The use of SMC products with production equipment for the manufacture of weapons of mass destruction (WMD) or
any other weapon is strictly prohibited.

2. The exports of SMC products or technology from one country to another are governed by the relevant security laws
and regulations of the countries involved in the transaction. Prior to the shipment of a SMC product to another
country, assure that all local rules governing that export are known and followed.

Back page 2
51-SY-B.qxd 09.3.18 11:11 AM Page 48

Series 51-SY5000/7000/9000
Specific Product Precautions 1
Be sure to read before handling.
Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC
Products” (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.

Manual Override Exhaust Side

Warning Caution
 Non-locking push type [Standard] The 51-SY series pilot valve and main valve share a common ex-
haust inside the valve. Therefore, do not block the exhaust port
Press in the direction of the arrow.
when arranging the piping.

Series 51-SY5000/7000/9000
Used as a 3-Port Valve

Caution
In case of using a 5-port valve as a 3-port valve
The 51-SY5000/7000/9000 series can be used as normally
closed (N.C.) or normally open (N.O.) 3-port port valves by clos-
 Push-turn locking slotted type [Type D] ing one of the cylinder ports (A or B) with a plug. However, they
should be used with the exhaust ports kept open.
While pressing, turn in the direction of the arrow.
If it is not turned, it can be operated the same way as the non- Plug position B port A port
locking type. Type of actuation N.C. N.O.
Plug Plug
Number of solenoids

Locked position Single

Plug Plug
LOCK
Double

PUSH

How to Use Plug Connector


Caution
When operating the locking type D with a screwdriver, turn it Caution
gently using a watchmaker’s screwdriver.
1. Attaching and detaching connectors
[Torque: Less than 0.1 N·m]
• To attach a connector, hold the lever and connector unit be-
tween your fingers and insert straight onto the pins of the sole-
noid valve so that the lever’s pawl is pushed into the groove
and locks.
 Push-turn locking lever type [Type E]
• To detach a connector, remove the pawl from the groove by
While pressing, turn it the direction of the arrow.
pushing the lever downward with your thumb, and pull the con-
If it is not turned, it can be operated the same way as the non-
nector straight out.
locking type.
Cover
Locked position Lever Groove

DC polar indication Pin


LOCK

PUSH

Plug connector with cover


Caution
Plug connector
When locking the manual override on the push-turn locking
types (D, E), be sure to push it down before turning.
Turning without first pushing it down can cause damage to the
manual override and trouble such as air leakage, etc.

Back page 3
51-SY-B.qxd 09.3.18 11:11 AM Page 49

Series 51-SY5000/7000/9000
Specific Product Precautions 2
Be sure to read before handling.
Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC
Products” (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.

Interface Regulator

Caution
Specifications
Interface regulator model ARBY5000--P-2 ARBY5000-- A1
B1 -2 ARBY7000--P-2 ARBY7000-- A1
B1 -2

Applicable solenoid valve model 51-SY540(R) 51-SY740(R)


Regulated port P A B P A B
Set pressure range 0.1 to 0.7 MPa
Maximum operating pressure 0.7 MPa
Fluid Air
Ambient and fluid temperature Max. 50°C
Pressure gauge connection port M5 x 0.8
With pressure gauge 66.8 g 110.8 g
Mass
With plug 60.4 g 103.2 g
Effective area on supply side Note 3) P→A, B — 7.61 mm2 — 13.54 mm2
Effective area on exhaust side Note 3) A, B→EA, EB 11.1 mm2 10.1 mm2 15.71 mm2 15.71 mm2
Note 1) Pressurize the interface regulator from P port on the base.
Note 2) With closed center and pressure center valves, the pressure can be regulated through P port only.
Note 3) Effective area, excluding the regulated port, when an inlet pressure of 0.5 MPa is supplied with regulators mounted on the solenoid valves (2-position) and
sub-plate. Refer to “Flow-rate Characteristics” regarding the regulated port.
Note 4) Valves for mass include gasket and mounting screws.
Note 5) With A, B ports regulated (P controlled A, B regulated), the effective area (Cv factor) for the regulated port and unregulated passage (P→B or P→A)
decreases as shown in the graph below when the set pressure is 0.25 MPa or less.
(A) (B)
2
Symbol 4
100
Effective area (Cv factor)%

(A) (B) (B) (A)


4 2 2 4

5 3 5 3 5 3
75 (EA) (EB) (EA) (EB) (EA) (EB)

50 1 1 1
0.1 0.15 0.2 0.25 (P) (P) (P)
Set pressure (MPa) P port regulated A port regulated B port regulated
(P controlled, (P controlled,
A regulated) B regulated)

How to Order Interface Regulator

ARBY5000 00 P 2 ARBY7000 00 P 2
Regulated port Regulated port
P P port P P port
A1 A port (P controlled, A regulated) A1 A port (P controlled, A regulated)
B1 B port (P controlled, B regulated) B1 B port (P controlled, B regulated)

Pressure gauge connection port Pressure gauge connection port


00 Pressure gauge (G15-10-01) 00 Pressure gauge (G15-10-01)
M1 Plug (M-5P) M1 Plug (M-5P)

Back page 4
51-SY-B.qxd 09.3.18 11:11 AM Page 50

Series 51-SY5000/7000/9000
Specific Product Precautions 3
Be sure to read before handling.
Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC
Products” (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.

Flow-rate Characteristics (Conditions: Inlet pressure 0.7 MPa when 2-position solenoid valve is mounted.)

ARBY5000 A1 regulated (P→A),


P regulated (P→A, B) B1 regulated (P→B)
0.6 0.6
Outlet pressure (MPa)

Outlet pressure (MPa)


0.5 0.5
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 0
0 100 200 300 400 500 600 700 0 100 200 300 400 500 600 700

Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

ARBY7000 A1 regulated (P→A),


P regulated (P→A, B) B1 regulated (P→B)
Outlet pressure (MPa)

Outlet pressure (MPa)

0.6 0.6
0.5 0.5
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 0
0 200 400 600 800 1000 1200 0 200 400 600 800 1000 1200 1400

Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

Back page 5
51-SY-B.qxd 09.3.18 11:11 AM Page 51

Series 51-SY5000/7000/9000
Specific Product Precautions 4
Be sure to read before handling.
Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC
Products” (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.

One-touch Fittings Other Tubing Brands

Warning Caution
1. Please take antistatic precautions appropriate to the 1. When using other than SMC brand tubing, confirm
use of resin tubing. that the following specifications are satisfied with re-
Refer to “Recommended Practices for Explosion-Protected spect to the outside diameter tolerance of the tub-
Electrical Installations in General Industries” issued by Tech- ing.
nology Institution of Industrial Safety. 1) Nylon tubing within ±0.1 mm
2) Soft nylon tubing within ±0.1 mm
Caution 3) Polyurethane tubing within +0.15 mm,
within –0.2 mm.
The pitch determined for each of the 51-SY series piping ports
Do not use tubing which do not meet these outside diameter
(P, A, B, etc.) is based on the assumption that KJ series one-
tolerances. It may not be possible to connect them, or they
touch fittings will be used.
may cause other trouble, such as air leakage or the tubing
For this reason, other pipe fittings may interfere with each other
pulling out after connection.
depending on their type and size. Dimensions should be con-
firmed in a pipe fitting catalog before they are used.
• Tubing attachment/detachment for one-touch fittings Solenoid Valve Mounting
1) Attaching of tubing
1. Take a tubing having no flaws on its periphery and cut it off
at a right angle. When cutting the tubing, use tubing cutters Caution
TK-1, 2 or 3. Do not use pinchers, nippers or scissors, etc. Mount it so that there is no slippage or deformation in
If cutting is done with tools other than tubing cutters, the gaskets, and tighten with the tightening torque as
tubing may be cut diagonally or become flattened, etc., shown below.
making a secure installation impossible, and causing prob-
lems such as the tubing pulling out after installation or air Model Thread size Tightening torque
leakage. Allow some extra length in the tubing. 51-SY5000 M3 0.8 N·m
2. Grasp the tubing and push it in slowly, inserting it securely 51-SY7000 M4 1.4 N·m
all the way into the fitting. 51-SY9000 M3 0.8 N·m
3. After inserting the tubing, pull on it lightly to confirm that it
will not come out. If it is not installed securely all the way
into the fitting, this can cause problems such as air leakage
or the tubing pulling out.
2) Detaching of tubing
1. Push in the release button sufficiently, pushing its collar
equally around the circumference.
2. Pull out the tubing while holding down the release button so
that it does not come out. If the release button is not
pressed down sufficiently, there will be increased bite on
the tubing and it will become more difficult to pull it out.
3. When the removed tubing is to be used again, cut off the
portion which has been chewed before reusing it. If the
chewed portion of the tubing is used as is, this can cause
trouble such as air leakage or difficulty in removing the tub-
ing.
• The pitch determined for each of the 51-SY series piping ports
(A, B, etc.) is based on the assumption that KJ series one-
touch fittings will be used. For this reason, other pipe fittings
may interfere with each other depending on their type and
size. Dimensions should be confirmed in a pipe fitting catalog
before they are used.

Back page 6
51-SY-B.qxd 09.3.18 11:11 AM Page 52

Series 51-SY5000/7000/9000
Specific Product Precautions 5
Be sure to read before handling.
Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC
Products” (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.

Valve Selection for Hazardous Environment

Warning
The explosion-proof performance of the 51-SY (intrinsically safe explosion-proof system) is ExiaIIBT4 (See the reference “Explosion-
proof Structure Symbol (ExiaIIBT4)”). Selection of a valve for a dangerous place should be done in accordance with “Recommended
Practices for Explosion-Protected Electrical Installations in General Industries” issued by Technology Institution of Industrial Safety.

Classification of Hazardous Environment

Warning
This valve should be used in a class-1 or class-2 environment by (Places often falling into the class-2 environment)
combining with a barrier (placed in non-hazardous location). a) A place where dangerous gas or liquid can leak from a con-
tainer if the container is corroded.
Note that this valve can not be used in a class-0 envir-
b) A place where dangerous gas or liquid can be released or leak
onment. out due to incorrect operation of equipment or an abnormal re-
Classification of hazardous environment action of equipment after exposure to high temperature and
high pressure.
 Class-0 environment ·········· Not available
c) A place where a dangerous atmosphere is generated due to
A place where an explosive atmosphere is constantly generated
failure of mandatory ventilation equipment and stagnation of
or can be generated.
explosive gas.
Also, a place where atmosphere is above the lower limit of explo-
sion constantly or for a long time of period is also regarded as the d) A place which is indoors around or next to the class-1 environ-
class-0 environment for safety season. ment and rarely has explosive gas with dangerous concentra-
tion.
(Places often falling into the class-0 environment)
a) A container of flammable liquid or space above the liquid level
in the container. Prohibition of Disassembly and Modification
b) Around the liquid level of flammable liquid in an open container
or similar place.
 Class-1 environment ·········· Available
Warning
A place where an explosive atmosphere can be generated peri- Disassembling the pilot valve and barrier can deterior-
odically or occasionally. ate the explosion-proof performance, and it may lead to
Also, a place which can have a dangerous concentration of ex- an accident.
plosive gas due to repair, maintenance, or leakage. Therefore, please do not disassemble or modify the pilot valve
(Places often falling into the class-1 environment) and barrier.
a) Around an opening which releases explosive gas due to re-
moval of a product during normal operation, opening/closing of
a lid, or operation of a safety valve. Intrinsically Safe Explosion-proof Circuit Wiring
b) Around the opening of a container such as a tanker and drum
which is filled with flammable liquid. Warning
c) Around an opening which releases explosive gas due to occa-
sional operation of a relief valve.
Wiring of intrinsically safe explosion-proof circuits
d) Around the opening of a gas-vent on a tank etc. should not be routed with the other circuits. Also, it
e) Around an opening which releases explosive gas during in- should not have electrostatic induction or electromag-
spection or repair work. netic induction.
f) A room or a place which can have explosive gas due to insuffi-
cient ventilation.
g) The part which is above the roof of a floating roof tank but
within the shell.
h) A place which can have leaked explosive gas and can accu-
mulate the gas such as a pit.
 Class-2 environment ·········· Available
A place where explosive atmosphere can be generated under ab-
normal condition though an explosive atmosphere cannot be
generated under normal condition.
1) A place where flammable gas is constantly operated, but it is
enclosed in an air-tight container or facility, and concentration
of the gas may be thick when the container or facility gets
broken due to an accident or when operation fails.
2) A place that can have a dangerous explosive gas concentra-
tion due to the breakage of mechanical ventilation equipment
though the equipment is usually reliable.

Back page 7
51-SY-B.qxd 09.3.18 11:11 AM Page 53

Series 51-SY5000/7000/9000
Specific Product Precautions 6
Be sure to read before handling.
Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC
Products” (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.

Reference
Explosion-proof Structure Symbol (ExiaIIBT4)
Symbols Specified by Technical Standard
Ex ia T4
Temperature classification:
Gas of T1 to T4
Group: II
Classification of gas: Gas of A and B
Type of explosion-proof structure: Intrinsically safe
explosion-proof structure (system)
A symbol of the explosion-proof structure based on
Technical Standard (rev.)

(1) Groups of explosion-proof equipment


Explosion-proof equipment is classified into two groups de-
pending on the place where electric equipment is used.
Group I: Electric equipment which is used in a dangerous en-
vironment within a tunnel or mine
Group II: Electric equipment which is used in a dangerous en-
vironment within a factory or office.
SMC valve belongs to Group II.
(2) Classification of gas
Classification of gas corresponds to the explosion class of
gas specified in the conventional standard, and there are
three classes, A, B, and C, depending on the characteristics
of explosive gas. The classification of gas specifies the dan-
gerous degree as C>B>A. SMC valve is applicable to the ga-
ses classified into A and B.
(3) Temperature class
Temperature class corresponds to the ignition degree of gas
specified in the conventional standard, and there are six clas-
ses, T1 to T6. T1 is the least dangerous gas which has the
highest ignition temperature, and T6 is the most dangerous
gas which has the lowest ignition temperature. SMC valve is
applicable to T1 to T4 temperature classes.

Back page 8
51-SY-B.qxd 09.3.18 11:11 AM Page 56

Record of changes
Edition B ∗ Deleted the system “C” and “E” from How to Order on
page 1, 14, 28, 34.
∗ Deleted the 51-SYE100-C from Zener Diode Barrier
Dimensions on page 41.
∗ Deleted the 51-SYE100-E from Insulating Barrier Dimensions
on page 42. NQ

Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.

You might also like