(Challenges and Advances in Computational Chemistry and Physics 24) Kunal Roy (eds.) - Advances in QSAR Modeling_ Applications in Pharmaceutical, Chemical, Food, Agricultural and Environmental Science.pdf
JPT Review Center (Arch. Pedro Santos Jr.) saleable and non-saleable lots in BP 220? 1. Based on the prescribed hierarchy of a. 30% saleable max, 70% non- roads and road widths in BP 220 and saleable min PD 957, which of the following is the b. 70% saleable max, 30% non- narrowest? saleable min a. Minor road c. 30% saleable min, 70% non- b. Alley saleable max c. Interconnecting road d. 70% saleable min, 30% non- d. Pathwalk saleable max e. None of the above 2. What is the maximum allowable riser height for stairs in BP 220? Remember: there is no prescribed ratio in BP a. 150 mm. 220. b. 175 mm. c. 200 mm. 8. What is the prescribed ratio for d. 250 mm. saleable and non-saleable lots in PD 957? 3. What is the minimum tread width for a. 30% saleable max, 70% non- stairs in BP 220? saleable min a. 200 mm. b. 70% saleable max, 30% non- b. 225 mm. saleable min c. 250 mm. c. 30% saleable min, 70% non- d. 300 mm. saleable max d. 70% saleable min, 30% non- 4. In terms of cost, which of the saleable max following is the most expensive? e. None of the above a. Economic housing b. Socialized housing Remember: PD 957 only caps the saleable c. Open market housing portion, and only places a minimum for the d. Medium cost housing non-saleable portion.
5. Which of the following is prohibited by 9. Which of the following is true?
BP 220 and PD 957? a. An alley may be used as a. A rowhouse cluster of 10 units property access for socialized b. A rowhouse cluster of 20 units developments only c. A rowhouse cluster 100 m. long b. A pathwalk may be used as d. A block 500.00m long with a property access for socialized 2.00m-wide alley approximately and economic developments at the center c. A pathwalk length of up to 60.00 m. is allowed The rest are all allowed. d. An alley must have a minimum width of 1.20 m. 6. For long blocks, an alley must be provided when the block becomes The other options are wrong. For (a), an alley _____ long or longer. can never be used as property access. For a. 200 m. (b), a pathwalk is only allowed as property b. 250 m. access for socialized projects, not economic. c. 300 m. For (d), should be 2 meters minimum. d. 500 m. 10. What is the minimum ceiling height b. A basketball court required for socialized and economic c. A private clinic housing (not including mezzanines)? d. A livelihood center a. 2.70 m. b. 2.40 m. 17. Which of the following are the first c. 2.10 m. three items on the list of minimum d. 2.00 m. basic needs of human settlements prescribed by BP 220? 11. What is the smallest door permitted by a. Water, power, and storm BP 220? drainage a. 600 mm. wide x 1800 mm. tall b. Water, circulation, and storm b. 700 mm. wide x 1800 mm. tall drainage c. 700 mm. wide x 2000 mm .tall c. Water, power, and waste d. 800 mm. wide x 2000 mm. tall disposal d. Water, parks and playgrounds, This is theoretically allowed for bathroom and circulation doors. 18. What is the minimum floor area 12. What is the acceptable range of required for a single occupancy, open handrail heights according to BP 220? market condominium according to PD a. 800-900 mm. from the floor 957? b. 800-100 mm. from the floor a. 18 sqm. c. 800-1200 mm. from the floor b. 22 sqm. d. 800-1500 mm.from the floor c. 36 sqm. d. 48 sqm. 13. For socialized housing, what is the minimum lot frontage required for 19. For medium-cost and open market single-detached developments? housing developments, what is the a. 6.00 m. minimum area required for parks and b. 8.00 m. playgrounds? c. 10.00 m. a. 3.5% of gross area d. 12.00 m. b. 4.0% of gross area c. 5.0% of gross area 14. What is the minimum front setback d. 9.0% of gross area required for socialized and economic housing? 20. What is the minimum floor area a. 1.00 m. required for open market housing? b. 1.50 m. a. 18 sqm. c. 2.00 m. b. 22 sqm. d. 4.50 m. c. 30 sqm. d. 42 sqm. 15. Parks and playgrounds are required for projects that have a minimum gross 21. What is the minimum level of area of ___ completion required for PD 957? a. 1 hectare a. Shell house b. 2 hectares b. Shell house with doors and c. 3 hectares windows d. 10 hectares c. Complete house d. Complete house without interior 16. Which of the following may be built on partitions areas allotted for parks and playgrounds? a. A multi-purpose center This is not low-cost housing. At the price points in PD 957, shell houses are not allowed.
22. What is the minimum lot area required
for medium cost, duplex housing? a. 50 sqm. b. 80 sqm. c. 100 sqm. d. 120 sqm.
23. For BP 220, what is the minimum
extension above the roof line required for firewalls? a. 200 mm. b. 300 mm. c. 400 mm. d. 1000 mm.
24. Subdivisions abutting main public
roads must provide setbacks on both sides of the subdivision entrance for public utility vehicles. What are the minimum dimensions required for the setback? a. 2.50 m. x 5.00 m. b. 3.00 m. x 5.00 m. c. 3.00 m. x 9.00 m. d. 3.60 m. x 12.00 m.
25. What is the minimum floor area
required for a medium cost family condominium according to PD 957? a. 18 sqm. b. 22 sqm. c. 36 sqm. d. 48 sqm.
(Challenges and Advances in Computational Chemistry and Physics 24) Kunal Roy (eds.) - Advances in QSAR Modeling_ Applications in Pharmaceutical, Chemical, Food, Agricultural and Environmental Science.pdf