Test Report issued under the responsibility of:

TEST REPORT
IEC/EN 60065
Audio, Video and Similar Electronic Apparatus: Safety Requirements

Report Reference No......................: 10-1330-0817(A2/M1)


Application No. .................................: 11-1330-0113
Tested by (name+ signature) ............ : Moon-seok Choi

Supervised by (name+ signature) ..... : N/A


Witnessed by (name+ signature) ...... : N/A
Approved by (name+ signature)........ : Young-hwan Kim

Date of issue.....................................: 2011-01-25


Total number of pages....................... 7 pages

CB Testing Laboratory...................: KTL (Korea Testing Laboratory)


Address.............................................: 222-13, Guro-3dong, Guro-gu, Seoul, 152-718, Korea
Testing location / procedure .............. : CBTL TMP WMT SMT RMT
Testing location / address.................. : Same as above
Applicant’s name............................: LG Electronics Inc.,
Address.............................................: 19 -1, Cheongho-ri, Jinwi-myeon, Pyeongteak-si, Gyeonggi-do, 451-
713, Korea
Test specification:
Standard ...........................................: IEC 60065:2001 + Amd 1:2005 / EN 60065:2002 + Amd 1:2006 +
Amd 11:2008 + National deviation for Singapore
Test procedure .................................: CB Scheme
Non-standard test method.………..: N/A
Test Report Form No......................: IEC60065G
Test Report Form(s) Originator ........: ASTA BEAB
Master TRF.......................................: Dated 2006-03
Copyright © 2006 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.

If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB
Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Page 2 of 7 Ref. No. : 10-1330-0817(A2/M1)

Test item description .................... : LCD Television Receiver


Trade Mark .......................................:

Manufacturer ....................................: Same as applicant


Factory..............................................: See page 4

Model/Type reference.......................: 32LK310-TA and Variants : see page 5


Ratings..............................................: AC 100-240 V~, 50/60 Hz, 1.2 A, 120 W, Class I for 32 inch
AC 100-240 V~, 50/60 Hz, 1.0 A, 100 W, Class I for 26 inch
Copy of marking plate

TRF No. IECEN60065G


Page 3 of 7 Ref. No. : 10-1330-0817(A2/M1)

General product information:


History of amendments and modifications;
(1) Ref. No. 10-1330-0817, dated 2010-12-10(original test report)
(2) Ref. No. 10-1330-0817(M1), dated 2010-12-16(modification report : 10-1330-0876)
(3) Ref. No. 10-1330-0817(A1/M1), dated 2011-01-10(amendment report : 11-1330-0007)
(4) Ref. No. 10-1330-0817(A2/M1), dated 2011-01-25(amendment report : 11-1330-0113)

Description of Change(s); for Ref. No. 10-1330-0817(M1)

(1) Addition of Annex ZB, ZC and Group and national deviation for EN 60065+A11:2008 according to
update of Standard (EN60065:2002+Amd 1:2006 Æ EN60065:2002+Amd 1:2006+Amd 11:2008)

Description of Change(s); for Ref. No. 10-1330-0817(A1/M1)

(1) Addition of Model No.;


- 32LK43##, 32LK43##-##, 32LK41##, 32LK41##-##

Description of Change(s); for Ref. No. 10-1330-0817(A2/M1)

(1) Addition of Model No.;


- 26LK33##, 26LK33##-##

- Note:
The modifications made on the relevant pages are marked with this style.

TRF No. IECEN60065G


Page 4 of 7 Ref. No. : 10-1330-0817(A2/M1)

Manufacturer and factory address :


♦ Manufacturer:
1. LG Electronics Inc.,
19 -1, Cheongho-ri, Jinwi-myeon, Pyeongteak-si, Gyeonggi-do, 451-713, Korea

♦ Factory address:
1. LG Electronics Inc.,
299 GONGDAN-DONG GUMI-SI GYEONGSANGBUK-DO 730-906 KOREA

2. LG Electronics Mlawa Sp. Z.O.O


UL.LGElectronics7Street06-500MlawaPoland
3. LG Electronics de Sao Paulo Ltda.
AvenidaDomPedroI,W-7777,DistritoIndustrialPiracangaguaII,Taubate,SaoPaoloBrazil

4. LG Electronics Wales Ltd.


Imperial Park, Newport, South Wales NP10 8ZY, U.K.

5. LG Electronics (Nanjing) Display Co., Ltd.


No. 346 Yaoxin Road, Qixia Nanjing, 210038 China
6. LG Mitr Electronics Co., Ltd.
84 MOO 12 PHETKASEM ROAD, K. M.22 SAMUTSAKORN 74130, THAILAND

7. LG Electronics (Thailand) Co., Ltd


192, Moo 1, Pluakdaeng Road, Tambon Tasith, Ampur Pluakdaeng 21140 Rayong Thailand

8. LG Electronics RUS,LLC
Russian Federation
b.9 86km of Minskoe Highway, Rural village Dorokhovskoe, Ruza district Moscow region 143160

9. PT LG Electronics Indonesia
Block GMM2100 Industrial Town, Cikarang Barat, Bekasi Jawa Barat, 17520 Indonesia.

10. LG Electronics Reynosa S A DE C V


CARRETERA A MATAMOROS Y BRECHA E 99., APDO POSTAL 178., REYNOSA., TAMPS
MEXICO

11. LGElectronicsMexicaliS.A.DeC.V
Calle Orbita #36, Parque Industrial, Mexicali II, Mexicali B.C.C.P. 21600 Mexico

12. LG Electronics Wroclaw SP. Z o.o


ul. LG Electronics 1-2, Biskupice Podgorne 55-040 Kobierzyce Poland

TRF No. IECEN60065G


Page 5 of 7 Ref. No. : 10-1330-0817(A2/M1)

General Information
1. Model number covered by the scope of this test report is as follows;

32LK31##, 3 2 L K 3 1 # # - # #, 32LK33##, 3 2 L K 3 3 # # - # #,
1)2) 1)2) 3)4) 1)2) 1)2) 3)4)

32LK45##, 3 2 L K 4 5 # # - # #, 26LK31##, 2 6 L K 3 1 # # - # #,
1)2) 1)2) 3)4) 1)2) 1)2) 3)4)

32LK43##, 3 2 L K 4 3 # # - # #, 32LK41##, 32LK41##-##


1)2) 1)2) 3)4) 1)2) 1)2) 3)4)

26LK33##, 26LK33##-##
1)2) 1)2) 3)4)

(The symbols “#” in the model name can be any alphanumeric character or blank ,
not affecting safety.)

1),2) For Each “#”


May be any alphanumeric character or blank indicates Function or Spec Variation.
3) May be any alphanumeric character indicates different country for sales.
4) May be any alphanumeric character indicates Decoration variation.

2. We tested 32LK310-TA as a basic model for the most severe test conditions.

3. These models are intended to use of internal SMPS power boards as follows;
1) Model no. of SMPS power board: LGP32-11P
- Manufacturer: LG Electronics Inc.

Summary of testing:
- Prepared for Class I apparatus.
- Max. Normal load condition as Max. Bright and Max. Contrast

Summary of compliance with National Differences:


The sample(s) tested complies with the requirements of IEC 60065:2001 + Amd 1:2005 / EN 60065:2002 +
Amd 1:2006 + Amd 11:2008 + National deviation for Singapore. Compliance with European Special
National Conditions, Annex ZB, and A – Deviations, Annex ZC is recorded at the end of this report.

TRF No. IECEN60065G


Page 6 of 7 Ref. No. : 10-1330-0817(A2/M1)

Test item particulars.................................................. :


Classification of installation and use ........................... : Class I equipment
Supply Connection....................................................... : Appliance inlet
...................................................................................... :
...................................................................................... :
Possible test case verdicts:
- test case does not apply to the test object................. : N/A
- test object does meet the requirement....................... : P (Pass)
- test object does not meet the requirement ................ : F (Fail)
Testing.......................................................................... :
Date of receipt of test item............................................ : -

Date (s) of performance of tests ................................... : -

General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
”(see Enclosure #)” refers to additional information appended to the report.
”(see appended table)” refers to a table appended to the report.

Throughout this report a point (comma) is used as the decimal separator.

TRF No. IECEN60065G


Page 7 of 7 Ref. No. : 10-1330-0817(A2/M1)

< Photo 1 > 26LK33##

< Photo 2 > 26LK33##

TRF No. IECEN60065G


Test Report issued under the responsibility of:

TEST REPORT
IEC/EN 60065
Audio, Video and Similar Electronic Apparatus: Safety Requirements

Report Reference No......................: 10-1330-0817(A1/M1)


Application No. .................................: 11-1330-0007
Tested by (name+ signature) ............ : Moon-seok Choi

Supervised by (name+ signature) ..... : N/A


Witnessed by (name+ signature) ...... : N/A
Approved by (name+ signature)........ : Young-hwan Kim

Date of issue.....................................: 2011-01-10


Total number of pages....................... 7 pages

CB Testing Laboratory...................: KTL (Korea Testing Laboratory)


Address.............................................: 222-13, Guro-3dong, Guro-gu, Seoul, 152-718, Korea
Testing location / procedure .............. : CBTL TMP WMT SMT RMT
Testing location / address.................. : Same as above
Applicant’s name............................: LG Electronics Inc.,
Address.............................................: 19 -1, Cheongho-ri, Jinwi-myeon, Pyeongteak-si, Gyeonggi-do, 451-
713, Korea
Test specification:
Standard ...........................................: IEC 60065:2001 + Amd 1:2005 / EN 60065:2002 + Amd 1:2006 +
Amd 11:2008 + National deviation for Singapore
Test procedure .................................: CB Scheme
Non-standard test method.………..: N/A
Test Report Form No......................: IEC60065G
Test Report Form(s) Originator ........: ASTA BEAB
Master TRF.......................................: Dated 2006-03
Copyright © 2006 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.

If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB
Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Page 2 of 7 Ref. No. : 10-1330-0817(A1/M1)

Test item description .................... : LCD Television Receiver


Trade Mark .......................................:

Manufacturer ....................................: Same as applicant


Factory..............................................: See page 3

Model/Type reference.......................: 32LK310-TA and Variants : see page 4


Ratings..............................................: AC 100-240 V~, 50/60 Hz, 1.2 A, 120 W, Class I for 32 inch
AC 100-240 V~, 50/60 Hz, 1.0 A, 100 W, Class I for 26 inch
Copy of marking plate

General product information:


History of amendments and modifications;
(1) Ref. No. 10-1330-0817, dated 2010-12-10(original test report)
(2) Ref. No. 10-1330-0817(M1), dated 2010-12-16(modification report : 10-1330-0876)
(3) Ref. No. 10-1330-0817(A1/M1), dated 2011-01-10(amendment report : 11-1330-0007)

Description of Change(s); for Ref. No. 10-1330-0817(M1)

(1) Addition of Annex ZB, ZC and Group and national deviation for EN 60065+A11:2008 according to
update of Standard (EN60065:2002+Amd 1:2006 Æ EN60065:2002+Amd 1:2006+Amd 11:2008)

Description of Change(s); for Ref. No. 10-1330-0817(A1/M1)

(1) Addition of Model No.;


- 32LK43##, 32LK43##-##, 32LK41##, 32LK41##-##

- Note:
The modifications made on the relevant pages are marked with this style.

TRF No. IECEN60065G


Page 3 of 7 Ref. No. : 10-1330-0817(A1/M1)

Manufacturer and factory address :


♦ Manufacturer:
1. LG Electronics Inc.,
19 -1, Cheongho-ri, Jinwi-myeon, Pyeongteak-si, Gyeonggi-do, 451-713, Korea

♦ Factory address:
1. LG Electronics Inc.,
299 GONGDAN-DONG GUMI-SI GYEONGSANGBUK-DO 730-906 KOREA

2. LG Electronics Mlawa Sp. Z.O.O


UL.LGElectronics7Street06-500MlawaPoland
3. LG Electronics de Sao Paulo Ltda.
AvenidaDomPedroI,W-7777,DistritoIndustrialPiracangaguaII,Taubate,SaoPaoloBrazil

4. LG Electronics Wales Ltd.


Imperial Park, Newport, South Wales NP10 8ZY, U.K.

5. LG Electronics (Nanjing) Display Co., Ltd.


No. 346 Yaoxin Road, Qixia Nanjing, 210038 China
6. LG Mitr Electronics Co., Ltd.
84 MOO 12 PHETKASEM ROAD, K. M.22 SAMUTSAKORN 74130, THAILAND

7. LG Electronics (Thailand) Co., Ltd


192, Moo 1, Pluakdaeng Road, Tambon Tasith, Ampur Pluakdaeng 21140 Rayong Thailand

8. LG Electronics RUS,LLC
Russian Federation
b.9 86km of Minskoe Highway, Rural village Dorokhovskoe, Ruza district Moscow region 143160

9. PT LG Electronics Indonesia
Block GMM2100 Industrial Town, Cikarang Barat, Bekasi Jawa Barat, 17520 Indonesia.

10. LG Electronics Reynosa S A DE C V


CARRETERA A MATAMOROS Y BRECHA E 99., APDO POSTAL 178., REYNOSA., TAMPS
MEXICO

11. LGElectronicsMexicaliS.A.DeC.V
Calle Orbita #36, Parque Industrial, Mexicali II, Mexicali B.C.C.P. 21600 Mexico

12. LG Electronics Wroclaw SP. Z o.o


ul. LG Electronics 1-2, Biskupice Podgorne 55-040 Kobierzyce Poland

TRF No. IECEN60065G


Page 4 of 7 Ref. No. : 10-1330-0817(A1/M1)

General Information
1. Model number covered by the scope of this test report is as follows;

32LK31##, 3 2 L K 3 1 # # - # #, 32LK33##, 3 2 L K 3 3 # # - # #,
1)2) 1)2) 3)4) 1)2) 1)2) 3)4)

32LK45##, 3 2 L K 4 5 # # - # #, 26LK31##, 2 6 L K 3 1 # # - # #,
1)2) 1)2) 3)4) 1)2) 1)2) 3)4)

32LK43##, 3 2 L K 4 3 # # - # #, 32LK41##, 32LK41##-##


1)2) 1)2) 3)4) 1)2) 1)2) 3)4)

(The symbols “#” in the model name can be any alphanumeric character or blank ,
not affecting safety.)

1),2) For Each “#”


May be any alphanumeric character or blank indicates Function or Spec Variation.
3) May be any alphanumeric character indicates different country for sales.
4) May be any alphanumeric character indicates Decoration variation.

2. We tested 32LK310-TA as a basic model for the most severe test conditions.

3. These models are intended to use of internal SMPS power boards as follows;
1) Model no. of SMPS power board: LGP32-11P
- Manufacturer: LG Electronics Inc.

Summary of testing:
- Prepared for Class I apparatus.
- Max. Normal load condition as Max. Bright and Max. Contrast

Summary of compliance with National Differences:


The sample(s) tested complies with the requirements of IEC 60065:2001 + Amd 1:2005 / EN 60065:2002 +
Amd 1:2006 + Amd 11:2008 + National deviation for Singapore. Compliance with European Special
National Conditions, Annex ZB, and A – Deviations, Annex ZC is recorded at the end of this report.

TRF No. IECEN60065G


Page 5 of 7 Ref. No. : 10-1330-0817(A1/M1)

Test item particulars.................................................. :


Classification of installation and use ........................... : Class I equipment
Supply Connection....................................................... : Appliance inlet
...................................................................................... :
...................................................................................... :
Possible test case verdicts:
- test case does not apply to the test object................. : N/A
- test object does meet the requirement....................... : P (Pass)
- test object does not meet the requirement ................ : F (Fail)
Testing.......................................................................... :
Date of receipt of test item............................................ : -

Date (s) of performance of tests ................................... : -

General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
”(see Enclosure #)” refers to additional information appended to the report.
”(see appended table)” refers to a table appended to the report.

Throughout this report a point (comma) is used as the decimal separator.

TRF No. IECEN60065G


Page 6 of 7 Ref. No. : 10-1330-0817(A1/M1)

< Photo 1 > 32LK43##

< Photo 2 > 32LK43##

TRF No. IECEN60065G


Page 7 of 7 Ref. No. : 10-1330-0817(A1/M1)

< Photo 3 > 32LK41##

< Photo 4 > 32LK41##

TRF No. IECEN60065G


Ref. Certif. No.
KR-4559M1

IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES SYSTEM CEI D'ACCEPTATION MUTUELLE DE CERTIFICATS D'ESSAIS
FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE OC

CB TEST CERTIFICATE CERTIFICAT D'ESSAI OC

Product LCD Television Receiver


Produit

Name and address of the Applicant LG Electronics Inc.,


Nom et adresse du demandeur 19 -1, Cheongho-ri, Jinwi-myeon, Pyeongteak-si, Gyeonggi-do, 451-713,
Korea, Republic of

Name and address of the manufacturer LG Electronics Inc.,


Nom et adresse du fabricant 19 -1, Cheongho-ri, Jinwi-myeon, Pyeongteak-si, Gyeonggi-do, 451-713,
Korea, Republic of

Name and address of the factory LG Electronics Inc.,


Nom et adresse de l'usine 299 GONGDAN-DONG GUMI-SI GYEONGSANGBUK-DO 730-906
Korea, Republic of

Rating and principal characteristics AC 100-240 V~, 50/60 Hz, 1.2 A, 120 W, Class I for 32 inch
Valeurs nominales et caractéristiques principales AC 100-240 V~, 50/60 Hz, 1.0 A, 100 W, Class I for 26 inch

Trademark (if any)


Marque de fabrique (si elle existe)

Type of manufacturer's Testing Laboratories used


Type de programme de laboratoire d'essais constructeur

Model / Type Ref. 32LK310-TA and variants [see the page 4 of 10-1330-0817(M1)
Ref. De type

Additional information (if neccessary may also be reported on page 2) Original issued : 2010-12-10
Les informations complémentaires (si nécessaire, peuvent être indiqué sur la Certificate KR-4559 is replaced by this version due to addition of annex ZB, ZC
2ème page) and group and national deviation.[see the page 2of 10-1330-0817(M1)]

A sample of Product was tested and found to be in conformity with IEC 60065(ed.7);am1
Un échantillon de ce produit a été essayé et été considéré conforme à la CEI Comments:
+ EN 60065:2002 + Amd 1:2006 + Amd 11:2008

National differences / Comments SG


Les différences nationales / Commentaires

As show in the Test Report Ref. No. which forms part of this certificate 10-1330-0817(M1)
Comme indiqué dans le Rapport d'essais numéro de référence qui constitue
partie de ce certificat

This CB Test Certificate is issued by the National Certification Body: Ce Certificat d'essai OC est établi par l'Organisme National de Certification

Korea Testing Laboratory (KTL)


222 - 13 Guro-3Dong, Guro-Gu, Seoul 152 - 718, Korea

Date: 2010-12-17 Signature: Mr. Hee-Soo KIM


page 1 of 2
Ref. Certif. No.
KR-4559M1

IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES SYSTEM CEI D'ACCEPTATION MUTUELLE DE CERTIFICATS D'ESSAIS
FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE OC

Additional factory

LG Electronics Mlawa Sp. Z.O.O LG Electronics de Sao Paulo Ltda.


UL.LGElectronics7Street06-500Mlawa AvenidaDomPedroI,W-
Poland 7777,DistritoIndustrialPiracangaguaII,Taubate,SaoPaolo
Brazil

LG Electronics Wales Ltd. LG Electronics (Nanjing) Display Co., Ltd.


Imperial Park, Newport, South Wales NP10 8ZY, No. 346 Yaoxin Road, Qixia Nanjing, 210038
United Kingdom China

LG Mitr Electronics Co., Ltd. LG Electronics (Thailand) Co., Ltd


84 MOO 12 PHETKASEM ROAD, K. M.22 SAMUTSAKORN 74130, 192, Moo 1, Pluakdaeng Road, Tambon Tasith, Ampur Pluakdaeng 21140
Thailand Rayong
Thailand

LG Electronics RUS,LLC PT LG Electronics Indonesia


b.9 86km of Minskoe Highway, Rural village Dorokhovskoe, Ruza district Block GMM2100 Industrial Town, Cikarang Barat, Bekasi Jawa Barat, 17520
Moscow region 143160 Indonesia
Russian Federation

LG Electronics Reynosa S A DE C V LGElectronicsMexicaliS.A.DeC.V


CARRETERA A MATAMOROS Y BRECHA E 99., APDO POSTAL 178., Calle Orbita #36, Parque Industrial, Mexicali II, Mexicali B.C.C.P. 21600
REYNOSA., TAMPS Mexico
Mexico

LG Electronics Wroclaw SP. Z o.o


ul. LG Electronics 1-2, Biskupice Podgorne 55-040 Kobierzyce
Poland

This CB Test Certificate is issued by the National Certification Body: Ce Certificat d'essai OC est établi par l'Organisme National de Certification

Korea Testing Laboratory (KTL)


222 - 13 Guro-3Dong, Guro-Gu, Seoul 152 - 718, Korea

Date: 2010-12-17 Signature: Mr. Hee-Soo KIM


page 2 of 2
Test Report issued under the responsibility of:

TEST REPORT
IEC/EN 60065
Audio, Video and Similar Electronic Apparatus: Safety Requirements

Report Reference No......................: 10-1330-0817(M1)


Application No. .................................: 10-1330-0876
Tested by (name+ signature) ............ : Moon-seok Choi

Supervised by (name+ signature) ..... : N/A


Witnessed by (name+ signature) ...... : N/A
Approved by (name+ signature)........ : Young-hwan Kim

Date of issue.....................................: 2010-12-16


Total number of pages....................... 10 pages

CB Testing Laboratory...................: KTL (Korea Testing Laboratory)


Address.............................................: 222-13, Guro-3dong, Guro-gu, Seoul, 152-718, Korea
Testing location / procedure .............. : CBTL TMP WMT SMT RMT
Testing location / address.................. : Same as above
Applicant’s name............................: LG Electronics Inc.,
Address.............................................: 19 -1, Cheongho-ri, Jinwi-myeon, Pyeongteak-si, Gyeonggi-do, 451-
713, Korea
Test specification:
Standard ...........................................: IEC 60065:2001 + Amd 1:2005 / EN 60065:2002 + Amd 1:2006 +
Amd 11:2008 + National deviation for Singapore
Test procedure .................................: CB Scheme
Non-standard test method.………..: N/A
Test Report Form No......................: IEC60065G
Test Report Form(s) Originator ........: ASTA BEAB
Master TRF.......................................: Dated 2006-03
Copyright © 2006 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.

If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB
Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Page 2 of 10 Ref. No. : 10-1330-0817(M1)

Test item description .................... : LCD Television Receiver


Trade Mark .......................................:

Manufacturer ....................................: Same as applicant


Factory..............................................: See page 3

Model/Type reference.......................: 32LK310-TA and Variants : see page 4


Ratings..............................................: AC 100-240 V~, 50/60 Hz, 1.2 A, 120 W, Class I for 32 inch
AC 100-240 V~, 50/60 Hz, 1.0 A, 100 W, Class I for 26 inch
Copy of marking plate

General product information:

History of amendments and modifications;


(1) Ref. No. 10-1330-0817, dated 2010-12-10(original test report)
(2) Ref. No. 10-1330-0817(M1), dated 2010-12-16(modification report : 10-1330-0876)

Description of Change(s); for Ref. No. 10-1330-0817(M1)

(1) Addition of Annex ZB, ZC and Group and national deviation for EN 60065+A11:2008 according to
update of Standard (EN60065:2002+Amd 1:2006 Æ EN60065:2002+Amd 1:2006+Amd 11:2008)

- Note:
The modifications made on the relevant pages are marked with this style.

TRF No. IECEN60065G


Page 3 of 10 Ref. No. : 10-1330-0817(M1)

Manufacturer and factory address :


♦ Manufacturer:
1. LG Electronics Inc.,
19 -1, Cheongho-ri, Jinwi-myeon, Pyeongteak-si, Gyeonggi-do, 451-713, Korea

♦ Factory address:
1. LG Electronics Inc.,
299 GONGDAN-DONG GUMI-SI GYEONGSANGBUK-DO 730-906 KOREA

2. LG Electronics Mlawa Sp. Z.O.O


UL.LGElectronics7Street06-500MlawaPoland
3. LG Electronics de Sao Paulo Ltda.
AvenidaDomPedroI,W-7777,DistritoIndustrialPiracangaguaII,Taubate,SaoPaoloBrazil

4. LG Electronics Wales Ltd.


Imperial Park, Newport, South Wales NP10 8ZY, U.K.

5. LG Electronics (Nanjing) Display Co., Ltd.


No. 346 Yaoxin Road, Qixia Nanjing, 210038 China
6. LG Mitr Electronics Co., Ltd.
84 MOO 12 PHETKASEM ROAD, K. M.22 SAMUTSAKORN 74130, THAILAND

7. LG Electronics (Thailand) Co., Ltd


192, Moo 1, Pluakdaeng Road, Tambon Tasith, Ampur Pluakdaeng 21140 Rayong Thailand

8. LG Electronics RUS,LLC
Russian Federation
b.9 86km of Minskoe Highway, Rural village Dorokhovskoe, Ruza district Moscow region 143160

9. PT LG Electronics Indonesia
Block GMM2100 Industrial Town, Cikarang Barat, Bekasi Jawa Barat, 17520 Indonesia.

10. LG Electronics Reynosa S A DE C V


CARRETERA A MATAMOROS Y BRECHA E 99., APDO POSTAL 178., REYNOSA., TAMPS
MEXICO

11. LGElectronicsMexicaliS.A.DeC.V
Calle Orbita #36, Parque Industrial, Mexicali II, Mexicali B.C.C.P. 21600 Mexico

12. LG Electronics Wroclaw SP. Z o.o


ul. LG Electronics 1-2, Biskupice Podgorne 55-040 Kobierzyce Poland

TRF No. IECEN60065G


Page 4 of 10 Ref. No. : 10-1330-0817(M1)

General Information
1. Model number covered by the scope of this test report is as follows;

32LK31##, 3 2 L K 3 1 # # - # #, 32LK33##, 3 2 L K 3 3 # # - # #,
1)2) 1)2) 3)4) 1)2) 1)2) 3)4)

32LK45##, 3 2 L K 4 5 # # - # #, 26LK31##, 2 6 L K 3 1 # # - # #,
1)2) 1)2) 3)4) 1)2) 1)2) 3)4)

(The symbols “#” in the model name can be any alphanumeric character or blank ,
not affecting safety.)

1),2) For Each “#”


May be any alphanumeric character or blank indicates Function or Spec Variation.
3) May be any alphanumeric character indicates different country for sales.
4) May be any alphanumeric character indicates Decoration variation.

2. We tested 32LK310-TA as a basic model for the most severe test conditions.

3. These models are intended to use of internal SMPS power boards as follows;
1) Model no. of SMPS power board: LGP32-11P
- Manufacturer: LG Electronics Inc.

Summary of testing:
- Prepared for Class I apparatus.
- Max. Normal load condition as Max. Bright and Max. Contrast

Summary of compliance with National Differences:


The sample(s) tested complies with the requirements of IEC 60065:2001 + Amd 1:2005 / EN 60065:2002 +
Amd 1:2006 + Amd 11:2008 + National deviation for Singapore. Compliance with European Special
National Conditions, Annex ZB, and A – Deviations, Annex ZC is recorded at the end of this report.

TRF No. IECEN60065G


Page 5 of 10 Ref. No. : 10-1330-0817(M1)

Test item particulars.................................................. :


Classification of installation and use ........................... : Class I equipment
Supply Connection....................................................... : Appliance inlet
...................................................................................... :
...................................................................................... :
Possible test case verdicts:
- test case does not apply to the test object................. : N/A
- test object does meet the requirement....................... : P (Pass)
- test object does not meet the requirement ................ : F (Fail)
Testing.......................................................................... :
Date of receipt of test item............................................ : 2010-12-13

Date (s) of performance of tests ................................... : 2010-12-13 until 2010-12-16

General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
”(see Enclosure #)” refers to additional information appended to the report.
”(see appended table)” refers to a table appended to the report.

Throughout this report a point (comma) is used as the decimal separator.

TRF No. IECEN60065G


Page 6 of 10 Ref. No. : 10-1330-0817(M1)

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

ZB ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS


2.6.1 DK: certain types of Class I apparatus, see Noticed N/A
15.1.1, may be provided with a plug not
establishing earthing continuity when inserted
in Danish socket-outlets
5.4 FI,NO,SE: CLASS I apparatus which is N/A
intended for connection to the building
installation wiring via a plug or an appliance
coupler, or both and in addition is intended
for connection to other apparatus or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network TERMINALS
and ACCESSIBLE parts, have a marking
stating that the apparatus must be connected
to an MAINS socket-outlet with protective
earth.
5.4.1 NO,SE: The screen of the cable distribution N/A
system is normally not earthed at the
entrance of the building and there is normally
no equipotential bonding system within the
building. Therefore the protective earthing of
the building installation need to be isolated
from the screen of a cable distribution
system.
NO,SE: It is however accepted to provide the N/A
insulation external to the equipment by an
adapter or an interconnection cable with
galvanic isolator, which may be provided by
e.g. a retailer.
NO,SE: The user manual shall then have the N/A
following or similar information in Norwegian
and Swedish language respectively,
depending on in what country the equipment
is intended to be used in:
“Equipment connected to the protective
earthing of the building installation through
the mains connection or through other
equipment with a connection to protective
earthing – and to a cable distribution system
using coaxial cable, may in some
circumstances create a fire hazard.
Connection to a cable distribution system has
therefore to be provided through a device
providing electrical isolation below a certain
frequency range (galvanic isolator, see EN
60728-11)”

TRF No. IECEN60065G


Page 7 of 10 Ref. No. : 10-1330-0817(M1)

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

NO,SE: NOTE In Norway, due to regulation for N/A


installations of cable distribution systems,
and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The
insulation shall withstand a dielectric strength
of 1,5 kV r.m.s., 50 Hz or 60 Hz, for 1 min.
13.3.1 NO: In Norway, due to IT power distribution Noticed N/A
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line
voltage, and will remain 230V in case of a
single earth fault.
15.1.1 DK: supply cords of single-phase appliances N/A
having a rated current not exceeding 13 A
shall be provided with a plug according to the
Heavy Current Regulations Section 107-2-D1.
DK: Appliances of CLASS I provided with No socket-outlets N/A
socket-outlets with earth contact or which are
intended to be used in locations where
protection against indirect contact is required
according to the wiring rules shall be
provided with a plug in accordance with the
Heavy Current Regulations, Section 107-2-D1
standard sheet DK 2-1a.
DK: Socket outlets intended for providing No socket-outlets N/A
power to CLASS II apparatus with a rated
current of 2,5 A shall be in accordance with
the Heavy Current Regulation, Section 107-2-
D1 standard sheet DKA 1-4a.
DK: Other current ratings socket outlets shall No socket-outlets N/A
be in compliance with the Heavy Current
Regulation, Section 107-2-D1 standard sheet
DKA 1-3a or DKA 1-3b.
DK: Mains socket-outlets with earthing No socket-outlets N/A
contact shall be in compliance with the Heavy
Current Regulation, Section 107-2-D1
standard sheet DK 1-3a, DK 1-5a or DK 1-7a.
GB: equipment fitted with a flexible cable or N/A
cord provided with a 13A BS 1363 plug as in
Statutory Instrument 1768:94
IE: equipment fitted with a flexible cable or N/A
cord provided with a 13 A plug in accordance
with Statutory Instrument 525:97
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with
the following amendments:
- dimensions 2,5 A, 250 V socket-outlets shall No socket-outlets N/A
comply with Standard Sheet I page 180 of
EN 60 065:2002

TRF No. IECEN60065G


Page 8 of 10 Ref. No. : 10-1330-0817(M1)

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

- mechanical strength 2,5 A, 250 V socket- N/A


outlets tested as specified in EN 60 065, 12.1.3
- protecting rim also tested N/A
NO: method b) of 8.1 is not permitted. Double No TNV circuit N/A
or reinforced insulation is required between
parts connected to the mains and parts
connected to the public telecommunications
network
J.2 NO: In Norway, due to IT power distribution N/A
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line
voltage, and will remain 230V in case of a
single earth fault.

ZC ANNEX ZC TO EN 60 065, A-DEVIATIONS


5.1 IT: additional markings on the outside of the TV Not CRT TV N/A
receiver in Italian language
IT: user instructions in Italian language N/A
including a conformity declaration
IT: certification number on the back cover N/A
6.1 DE: additional following requirement: N/A
- cathode ray tubes with an accelerating No cathode ray tubes N/A
voltage exceeding 40 kV, authorization is
required, or application of type approval and
marking
14 SE: Switches containing mercury such as No mercury N/A
thermostats, relays and level controllers are
not allowed.

TRF No. IECEN60065G


Page 9 of 10 Ref. No. : 10-1330-0817(M1)

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

Group and national deviations for EN 60065+A11: 2008

5.1 i) Replace the note by: P


NOTE: For RATED POWER CONSUMPTION P
measurements of TVs reference is made to
EN 62087. Measurements are done in the ON
(play) operating mode.
5.4.1 Add the following indent: N/A
za) For a PORTABLE SOUND SYSTEM, a N/A
warning that excessive sound pressure from
earphones and headphones can cause
hearing loss.
6.1 Replace the subclause by: N/A
6.1 Ionizing radiation No ionizing radiation N/A
Apparatus including a potential source of N/A
ionizing radiation shall be so constructed that
personal protection against ionizing radiation
is provided under normal operating
conditions and under fault conditions.
In addition to the normal operating N/A
conditions, all controls adjustable from the
outside BY HAND, by any object such as a
tool or a coin, and those internal adjustments
or pre-sets which are not locked in a reliable
manner, are adjusted so as to give maximum
radiation whilst maintaining an intelligible
picture for 1 h, at the end of which the
measurement is made.
NOTE 1 Soldered joints and paint lockings are N/A
examples of adequate locking.
The dose-rate is determined by means of a N/A
radiation monitor with an effective area of 10
cm², at any point 10 cm from the outer surface
of the apparatus.
Moreover, the measurement shall be made N/A
under fault conditions causing an increase of
the high-voltage, provided an intelligible
picture is maintained for 1 h, at the end of
which the measurement is made.
The dose-rate shall not exceed 1μSv/h (0,1 N/A
mR/h) taking account of the background level.
NOTE 2 These values appear in Directive N/A
96/29/Euratom of 13th May 1996.
A picture is considered to be intelligible if the N/A
following conditions are met:

TRF No. IECEN60065G


Page 10 of 10 Ref. No. : 10-1330-0817(M1)

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

- a scanning amplitude of at least 70 % of the


usable screen width;
- a minimum luminance of 50 cd/m² with
locked blank raster provided by a test
generator;
- a horizontal resolution corresponding to at
least 1,5 MHz in the centre, with a similar
vertical degradation;
- not more than one flashover per 5 min.
Z1 Add the following new clause after Clause 20: P
Z1 Resistance to candle flame ignition All combustible materials P
A television set shall be so designed that the used in the outer surface are
likelihood of ignition and the spread of fire min. Class V-1
caused by a candle flame is reduced. (see appended table 14)
NOTE 1 An apparatus with a viewing screen is N/A
not regarded to be a television set if it is
declared not to be so by the manufacturer.
This requirement does not apply to the N/A
display screen of rear projection TV’s.
NOTE 2 This exemption has been allowed N/A
because this technology is falling out of use
and it is expected that within a few years it
will no longer exist. This exemption will not
be extended to other technologies.
NOTE 3 The frame around the screen is not N/A
exempted from the requirements.
Wood and WOOD-BASED MATERIAL with a N/A
thickness of at least 6 mm is considered to
fulfill the V-1 requirement when applying
CLC/TS 62441.
Compliance is checked according to CLC/TS N/A
62441.
NOTE 4 The term vertical, as used in the first N/A
dash of clause 5.2 of CLC/TS 62441, does not
mean a perfectly vertical position. It should be
interpreted as any surface that can be
touched by the flame of a candle of 150 mm
height and 20mm diameter while the candle is
still touching the supporting surface. A
typical candle used in the home is assumed
to be 20 mm diameter.
NOTE 5 It is expected that CLC/TS 62441 will N/A
in the future be replaced by a standard, at
which time that standard will become
applicable, subject to a vote by National
Committees at the time.

TRF No. IECEN60065G


Ref. Certif. No.
KR-4559

IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES SYSTEM CEI D'ACCEPTATION MUTUELLE DE CERTIFICATS D'ESSAIS
FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE OC

CB TEST CERTIFICATE CERTIFICAT D'ESSAI OC

Product LCD Television Receiver


Produit

Name and address of the Applicant LG Electronics Inc.,


Nom et adresse du demandeur 19 -1, Cheongho-ri, Jinwi-myeon, Pyeongteak-si, Gyeonggi-do, 451-713,
Korea, Republic of

Name and address of the manufacturer LG Electronics Inc.,


Nom et adresse du fabricant 19 -1, Cheongho-ri, Jinwi-myeon, Pyeongteak-si, Gyeonggi-do, 451-713,
Korea, Republic of

Name and address of the factory LG Electronics Inc.,


Nom et adresse de l'usine 299 GONGDAN-DONG GUMI-SI GYEONGSANGBUK-DO 730-906
Korea, Republic of

Rating and principal characteristics AC 100-240 V~, 50/60 Hz, 1.2 A, 120 W, Class I for 32 inch
Valeurs nominales et caractéristiques principales AC 100-240 V~, 50/60 Hz, 1.0 A, 100 W, Class I for 26 inch

Trademark (if any)


Marque de fabrique (si elle existe)

Type of manufacturer's Testing Laboratories used


Type de programme de laboratoire d'essais constructeur

Model / Type Ref. 32LK310-TA and variants [see the page 4 of 10-1330-0817]
Ref. De type

Additional information (if neccessary may also be reported on page 2)


Les informations complémentaires (si nécessaire, peuvent être indiqué sur la
2ème page)

A sample of Product was tested and found to be in conformity with IEC 60065(ed.7);am1
Un échantillon de ce produit a été essayé et été considéré conforme à la CEI Comments:
+ EN 60065:2002 + Amd 1:2006

National differences / Comments SG


Les différences nationales / Commentaires

As show in the Test Report Ref. No. which forms part of this certificate 10-1330-0817
Comme indiqué dans le Rapport d'essais numéro de référence qui constitue
partie de ce certificat

This CB Test Certificate is issued by the National Certification Body: Ce Certificat d'essai OC est établi par l'Organisme National de Certification

Korea Testing Laboratory (KTL)


222 - 13 Guro-3Dong, Guro-Gu, Seoul 152 - 718, Korea

Date: 2010-12-10 Signature: Mr. Hee-Soo KIM


page 1 of 2
Ref. Certif. No.
KR-4559

IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES SYSTEM CEI D'ACCEPTATION MUTUELLE DE CERTIFICATS D'ESSAIS
FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE OC

Additional factory

LG Electronics Mlawa Sp. Z.O.O LG Electronics de Sao Paulo Ltda.


UL.LGElectronics7Street06-500Mlawa AvenidaDomPedroI,W-
Poland 7777,DistritoIndustrialPiracangaguaII,Taubate,SaoPaolo
Brazil

LG Electronics Wales Ltd. LG Electronics (Nanjing) Display Co., Ltd.


Imperial Park, Newport, South Wales NP10 8ZY, No. 346 Yaoxin Road, Qixia Nanjing, 210038
United Kingdom China

LG Mitr Electronics Co., Ltd. LG Electronics (Thailand) Co., Ltd


84 MOO 12 PHETKASEM ROAD, K. M.22 SAMUTSAKORN 74130, 192, Moo 1, Pluakdaeng Road, Tambon Tasith, Ampur Pluakdaeng 21140
Thailand Rayong
Thailand

LG Electronics RUS,LLC PT LG Electronics Indonesia


b.9 86km of Minskoe Highway, Rural village Dorokhovskoe, Ruza district Block GMM2100 Industrial Town, Cikarang Barat, Bekasi Jawa Barat, 17520
Moscow region 143160 Indonesia
Russian Federation

LG Electronics Reynosa S A DE C V LGElectronicsMexicaliS.A.DeC.V


CARRETERA A MATAMOROS Y BRECHA E 99., APDO POSTAL 178., Calle Orbita #36, Parque Industrial, Mexicali II, Mexicali B.C.C.P. 21600
REYNOSA., TAMPS Mexico
Mexico

LG Electronics Wroclaw SP. Z o.o


ul. LG Electronics 1-2, Biskupice Podgorne 55-040 Kobierzyce
Poland

This CB Test Certificate is issued by the National Certification Body: Ce Certificat d'essai OC est établi par l'Organisme National de Certification

Korea Testing Laboratory (KTL)


222 - 13 Guro-3Dong, Guro-Gu, Seoul 152 - 718, Korea

Date: 2010-12-10 Signature: Mr. Hee-Soo KIM


page 2 of 2
Test Report issued under the responsibility of:

TEST REPORT
IEC/EN 60065
Audio, Video and Similar Electronic Apparatus: Safety Requirements

Report Reference No......................: 10-1330-0817


Tested by (name+ signature) ............ : Moon-seok Choi

Supervised by (name+ signature) ..... : N/A


Witnessed by (name+ signature) ...... : N/A
Approved by (name+ signature)........ : Young-hwan Kim

Date of issue.....................................: 2010-12-10


Total number of pages....................... Test Report : 48 Pages

CB Testing Laboratory...................: KTL (Korea Testing Laboratory)


Address.............................................: 222-13, Guro-3dong, Guro-gu, Seoul, 152-718, Korea
Testing location / procedure .............. : CBTL TMP WMT SMT RMT
Testing location / address.................. : Same as above
Applicant’s name............................: LG Electronics Inc.,
Address.............................................: 19 -1, Cheongho-ri, Jinwi-myeon, Pyeongteak-si, Gyeonggi-do, 451-
713, Korea
Test specification:
Standard ...........................................: IEC 60065:2001 + Amd 1:2005 / EN 60065:2002 + Amd 1:2006 +
National deviation for Singapore
Test procedure .................................: CB Scheme
Non-standard test method.………..: N/A
Test Report Form No......................: IEC60065G
Test Report Form(s) Originator ........: ASTA BEAB
Master TRF.......................................: Dated 2006-03
Copyright © 2006 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.

If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB
Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Page 2 of 48 Ref. No. : 10-1330-0817

Test item description .................... : LCD Television Receiver


Trade Mark .......................................:

Manufacturer ....................................: Same as applicant


Factory..............................................: See page 3

Model/Type reference.......................: 32LK310-TA and Variants : see page 4


Ratings..............................................: AC 100-240 V~, 50/60 Hz, 1.2 A, 120 W, Class I for 32 inch
AC 100-240 V~, 50/60 Hz, 1.0 A, 100 W, Class I for 26 inch
Copy of marking plate

TRF No. IECEN60065G


Page 3 of 48 Ref. No. : 10-1330-0817

Manufacturer and factory address :


♦ Manufacturer:
1. LG Electronics Inc.,
19 -1, Cheongho-ri, Jinwi-myeon, Pyeongteak-si, Gyeonggi-do, 451-713, Korea

♦ Factory address:
1. LG Electronics Inc.,
299 GONGDAN-DONG GUMI-SI GYEONGSANGBUK-DO 730-906 KOREA

2. LG Electronics Mlawa Sp. Z.O.O


UL.LGElectronics7Street06-500MlawaPoland
3. LG Electronics de Sao Paulo Ltda.
AvenidaDomPedroI,W-7777,DistritoIndustrialPiracangaguaII,Taubate,SaoPaoloBrazil

4. LG Electronics Wales Ltd.


Imperial Park, Newport, South Wales NP10 8ZY, U.K.

5. LG Electronics (Nanjing) Display Co., Ltd.


No. 346 Yaoxin Road, Qixia Nanjing, 210038 China
6. LG Mitr Electronics Co., Ltd.
84 MOO 12 PHETKASEM ROAD, K. M.22 SAMUTSAKORN 74130, THAILAND

7. LG Electronics (Thailand) Co., Ltd


192, Moo 1, Pluakdaeng Road, Tambon Tasith, Ampur Pluakdaeng 21140 Rayong Thailand

8. LG Electronics RUS,LLC
Russian Federation
b.9 86km of Minskoe Highway, Rural village Dorokhovskoe, Ruza district Moscow region 143160

9. PT LG Electronics Indonesia
Block GMM2100 Industrial Town, Cikarang Barat, Bekasi Jawa Barat, 17520 Indonesia.

10. LG Electronics Reynosa S A DE C V


CARRETERA A MATAMOROS Y BRECHA E 99., APDO POSTAL 178., REYNOSA., TAMPS
MEXICO

11. LGElectronicsMexicaliS.A.DeC.V
Calle Orbita #36, Parque Industrial, Mexicali II, Mexicali B.C.C.P. 21600 Mexico

12. LG Electronics Wroclaw SP. Z o.o


ul. LG Electronics 1-2, Biskupice Podgorne 55-040 Kobierzyce Poland

TRF No. IECEN60065G


Page 4 of 48 Ref. No. : 10-1330-0817

General Information
1. Model number covered by the scope of this test report is as follows;

32LK31##, 3 2 L K 3 1 # # - # #, 32LK33##, 3 2 L K 3 3 # # - # #,
1)2) 1)2) 3)4) 1)2) 1)2) 3)4)

32LK45##, 3 2 L K 4 5 # # - # #, 26LK31##, 2 6 L K 3 1 # # - # #,
1)2) 1)2) 3)4) 1)2) 1)2) 3)4)

(The symbols “#” in the model name can be any alphanumeric character or blank ,
not affecting safety.)

1),2) For Each “#”


May be any alphanumeric character or blank indicates Function or Spec Variation.
3) May be any alphanumeric character indicates different country for sales.
4) May be any alphanumeric character indicates Decoration variation.

2. We tested 32LK310-TA as a basic model for the most severe test conditions.

3. These models are intended to use of internal SMPS power boards as follows;
1) Model no. of SMPS power board: LGP32-11P
- Manufacturer: LG Electronics Inc.

Summary of testing:
- Prepared for Class I apparatus.
- Max. Normal load condition as Max. Bright and Max. Contrast

Summary of compliance with National Differences:


The sample(s) tested complies with the requirements of IEC 60065:2001 + Amd 1:2005 / EN 60065:2002 +
Amd 1:2006 + National deviation for Singapore. Compliance with European Special National Conditions,
Annex ZB, and A – Deviations, Annex ZC is recorded at the end of this report.

TRF No. IECEN60065G


Page 5 of 48 Ref. No. : 10-1330-0817

Test item particulars.................................................. :


Classification of installation and use ........................... : Class I equipment
Supply Connection....................................................... : Appliance inlet
...................................................................................... :
...................................................................................... :
Possible test case verdicts:
- test case does not apply to the test object................. : N/A
- test object does meet the requirement....................... : P (Pass)
- test object does not meet the requirement ................ : F (Fail)
Testing.......................................................................... :
Date of receipt of test item............................................ : 2010-10-20

Date (s) of performance of tests ................................... : 2010-10-24 until 2010-12-10

General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
”(see Enclosure #)” refers to additional information appended to the report.
”(see appended table)” refers to a table appended to the report.

Throughout this report a point (comma) is used as the decimal separator.

TRF No. IECEN60065G


Page 6 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

3 GENERAL REQUIREMENTS
Safety class of the apparatus ................................. : Class I P

4 GENERAL CONDITIONS OF TESTS


4.1.4 Ventilation instructions require the use of the test No : Positioned in accordance N
box with the instructions

5 MARKING
Comprehensible and easily discernible On rear side of the enclosure P
Permanent durability against water and petroleum Tested with water and P
spirit petroleum spirit
5.1 Identification, maker, model ................................... : P
,
a), b)
32LK310-TA and variants : see
page 4
c) Class II symbol if applicable This equipment is Class I N
d), e) Rated supply voltage and symbol .......................... : AC 100-240 V~ P
f) Frequency if safety dependant 50/60 Hz P
g), h), i) Rated current or power consumption .................... : 1.2 A, 120 W or 1.0 A, 100 W P
5.2 a) Earth terminal Marked IEC 60417-5019 P
symbol(mains inlet with earth
terminal) :
b) Hazardous live terminals No hazardous live terminals N
c) Supply output terminals (other than mains) No supply output terminals N
5.3 Use of triangle with exclamation mark Marked on the circuit diagram P
5.4 Instructions for use By English P
5.4.1 Mains powered equipment not exposed to dripping Caution wording is written on P
or splashing. Warning concerning objects filled instruction
a)
with liquid, etc.
b) Hazardous live terminals, instructions for wiring No hazardous live terminals N
c) Instructions for replacing lithium battery No lithium battery N
Instructions for modem if fitted No modem N
d) Class I earth connection warning In user’s manual P
e) Instructions for multimedia system connection No such a connection N

TRF No. IECEN60065G


Page 7 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

f) Special stability warning for fixed installation The apparatus is tested to the N
stability requirements of 19.1-3
g) Warning: battery exposure to heat No battery N
h) Warning: protective film on CRT face No CRT N
5.4.2 Disconnect device: plug/coupler or all-pole mains Disconnect device : P
switch location, accessibility and markings Plug/coupler of power supply
cord,
Caution wording is written on
instruction
Instructions for permanently connected equipment This apparatus is not for N
permanently connection

6 HAZARDOUS RADIATION
6.1 Ionizing radiation < 36 pA/kg (0,5 mR/h) No ionizing unit N
6.1 European Council Directive 96/29/Euratom of 13 No ionizing unit N
May 1996 10cm from outer surface of apparatus
EN 60065
<1µSv/h (0,1mR/h)
6.2 Laser radiation, emission limits to IEC 60825-1 .... : No laser unit N
Emission limits under fault conditions .................... : N

7 HEATING UNDER NORMAL OPERATING CONDITIONS


7.1 Temperature rises not exceeding specified values, (see appended table 7.1) P
any single protective device defeated except those
of Cl. 7.1 a) and b)
7.1.1 Temperature rise of accessible parts (see appended table 7.1) P
7.1.2 Temperature rise of parts providing electrical (see appended table 7.1) P
insulation
7.1.3 Temperature rise of parts acting as a support or as (see appended table 7.1) P
a mechanical barrier
7.1.4 Temperature rise of windings (see appended table 7.1) P
7.1.5 Parts not subject to a limit under 7.1.1 to 7.1.4 (see appended table 7.1) P
7.2 Softening temperature of insulating material No insulating material N
supporting parts conductively connected to the supporting parts conductively
mains carrying a current > 0,2 A at least 150 oC connected to the Mains

TRF No. IECEN60065G


Page 8 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

8 CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION


AGAINST ELECTRIC SHOCK
8.1 Conductive parts covered by lacquer, paper, Considered as bare P
untreated textile oxide films and beads etc.
considered to be bare
8.2 No shock hazard when changing voltage setting Fuse-links not accessible by N
device, fuse-links or handling drawers etc. hand
8.3 Insulation of hazardous live parts not provided by No hygroscopic material N
hygroscopic material
8.4 No risk of electric shock following the removal of a No hazard P
cover which can be removed by hand
8.5 Class I equipment P
Basic insulation between hazardous live parts and P
earthed accessible parts
Resistors bridging basic insulation complying with N
14.1 a)
8.6 Class II equipment and Class II constructions within Class I equipment
Reinforced or double insulation between Provided reinforced or double P
hazardous live parts and accessible parts insulation
Components bridging reinforced or double Evaluated in certified power P
insulation complying with 14.1 a) or 14.3 supply board(LGP32-11P)
(see appended table 14)
Basic and supplementary insulation each being Evaluated in certified power P
bridged by a capacitor complying with 14.2.1 a) supply board(LGP32-11P)
(see appended table 14)
Reinforced or double insulation being bridged with N
2 capacitors in series complying with 14.2.1 a)
Reinforced or double insulation being bridged with Evaluated in certified power P
a single capacitor complying with 14.2.1 b) supply board(LGP32-11P)
(see appended table 14)
Basic insulation bridged by components complying N
with 14.3.4.3
8.7 This sub-clause is void N
N
8.8 Double Insulation: the Basic or Supplementary N
insulation > 0,4 mm (mm) ....................................... :

TRF No. IECEN60065G


Page 9 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

Reinforced insulation > 0,4 mm (mm) .................... : - Transformer bobbin P


thickness.: > 0.4 mm,
- Optocoupler : > 0.4 mm
Evaluated in certified power
supply board(LGP32-11P)
(see appended table 14)
Thin sheet insulation (excluding non-separable thin Insulation tape in transformer P
sheet insulation. See 8.22) Evaluated in certified power
supply board(LGP32-11P)
(see appended table 14)
Basic or supplementary insulation, at least two N
layers, each meeting 10.3 dielectric
Basic or supplementary insulation, three layers any N
two of which meet 10.3 dielectric
Reinforced insulation, two layers each of which N
meet 10.3 dielectric
Reinforced insulation, three layers any two which Two layers : 4,240 Vpeak P
meet 10.3 dielectric tested
8.9 Primary Wiring: Adequate insulation between Provided double insulation P
internal hazardous live conductors and accessible
parts
Secondary Wiring: Adequate insulation between Dressed away from live parts P
internal hazardous live parts and conductors
connected to accessible parts
8.10 Class II Wiring: This equipment is Class I N
(1) Primary: Double insulation between conductors
connected to the mains and accessible parts.
(2) Secondary: Double insulation between
conductors connected to accessible parts and the
mains
8.11 Detaching of wires P
No undue reduction of creepages or clearance Connector used : Wires P
distances if wires become detached secured
Vibration test carried out ........................................ : Yes : No hazard P
8.12 This sub-clause is void No socket outlets N
8.13 Adequate fastening of windows, lenses, lamp Not exist N
covers etc. (pull test 20 N for 10 s)
8.14 Adequate fastening of covers (pull test 50 N for P
10 s)

TRF No. IECEN60065G


Page 10 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

8.15 No risk of damage to the insulation of internal No hazard : Wires are dressed P
wiring due to hot parts or sharp edges (2N force) away from hot parts or sharp
edges
8.16 Only special supply equipment can be used Not powered by special supply N
8.17 Insulated winding wire without additional N
interleaved insulation
8.18 Endurance test as required by 8.17 N
8.19 Disconnection from the mains P
8.19.1 Disconnect device Type : Mains Plug/coupler P
used
All-pole switch or circuit breaker with >3mm No all-pole switch or circuit N
contact separation breaker
8.19.2 Mains switch ON indication No mains switch N
8.20 Switch not fitted in the mains cord No switch N
8.21 Bridging components comply with clause 14 No bridging N
8.22 Test of non-separable thin sheet material N

9 ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS


9.1 Testing on the outside P
9.1.1 For voltages >1000 V ac or >1500 V dc complies < 1000 Vac or < 1500 Vdc N
with clause 13.3.1 for basic insulation
9.1.1.1 a) Determination of Hazardous Live parts P
b) Touch current measured from terminal devices U1 : 0.870 Vpeak P
using the network in annex D ................................. : U2 : 0.204 Vpeak
c) Discharge not exceeding 45 μC < 45 μC P
d) Energy of discharge not exceeding 350 mJ No part or contact of a terminal N
with stored voltages exceeding
15 kV
9.1.1.2 Test with test finger and test probe Does not touch hazardous P
parts
9.1.2 No hazardous live shafts of knobs, handles or No live shafts N
levers
9.1.3 Ventilation holes and other holes tested by means Hole size : Dia. < 4.0 mm, P
of 4 mm x 100 mm test pin
Does not touch hazardous
parts
9.1.4 Terminal devices – within 25mm tested with Does not touch hazardous P
1 mm x 20 mm test pin (10 N); test probe D of IEC parts
61032

TRF No. IECEN60065G


Page 11 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

Terminal devices tested with 1 mm x 100 mm Does not touch hazardous P


straight wire (1 N); test probe D of IEC 61032 parts
9.1.5 Pre-set controls tested with 2.5 mm x 100 mm test No pre-set controls N
pin (10 N); test probe C of IEC 61032
9.1.6 No shock hazard due to stored charge on Apparatus on and stand-by P
withdrawal of the mains plug; voltage (V) after 2 s : mode : 23 Vpeak after 2 sec
If C is not greater than 0,1 μF no test needed C : > 0.1 μF N
9.1.7 Enclosure sufficiently resistant to external force No damaged, No hazard P
a) Test probe 11 of IEC 61032 for 10 s (50 N) No hazard P
b) Test hook of fig. 4 for 10 s (20 N) No hazard P
c) Conductive enclosure: 30 mm diameter test tool for No conductive enclosure N
5 s (100 or 250 N) ................................................... :
9.2 No hazard after removing a cover by hand No cover removable by hand N

10 INSULATION REQUIREMENTS
10.1 Insulation resistance (MΩ) at least 2 MΩ min. after > 100 MΩ P
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
10.2 Humidity treatment 48 h or 120 h ........................... : 120 h, 40 °C, 93 % P
10.3 Insulation resistance and dielectric strength (see appended table) P
between mains terminals
Insulation resistance and dielectric strength across (see appended table) P
BASIC or SUPPLEMENTARY insulation (Class 1)
Insulation resistance across REINFORCED (see appended table) P
insulation (Class II)

11 FAULT CONDITIONS
11.1 No shock hazard under fault condition P
11.2 Heating under fault condition P
No hazard from softening solder P
No flaming more than 10s (see appended table 11.2) P
Soldered terminations not used as protective (see appended table 11.2) P
mechanism
11.2.1 Measurement of temperature rises (see appended table 11.2) P
11.2.2 Temperature rise of accessible parts (see appended table 11.2) P

TRF No. IECEN60065G


Page 12 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

11.2.3 Temperature rise of parts, other than windings, (see appended table 11.2) P
providing electrical insulation
Temperature rise of printed circuit boards (PCB) Not exceeding the limits of N
exceeding the limits of table 3 by max. 100 K for table 3
max. 5 min
a) Temperature rise of printed circuit boards (PCB) N
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
b) Temperature rise of printed circuit boards (PCB) N
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
Meets all the special conditions if conductors on N
printed circuit boards are interrupted
Class I protective earthing maintained The continuity of any protective P
Earthing maintained.
11.2.4 Temperature rise of parts acting as a support or P
mechanical barrier
11.2.5 Temperature rise of windings (see appended table 11.2) P
11.2.6 Temperature rise of parts not subject to the limits (see appended table 11.2) P
of 11.2.1 to 11.2.5

12 MECHANICAL STRENGTH
12.1.1 Bump test where mass >7 kg Mass : 9.6 kg, P
No damaged, No hazard
12.1.2 Vibration test (portable, metal, musical amps) Tested : No damaged, No P
hazard
12.1.3 Impact hammer test 0.5 J tested : No damaged, No P
hazard, Withstand 4,240 Vp
Steel ball test (for non-ventilated solid areas) 2 J tested : No damaged, No P
hazard, Withstand 4,240 Vp
12.1.4 Drop test for portable apparatus where mass = 7 Not portable N
kg
12.1.5 Thermoplastic enclosures stress relief test Tested, 70 ºC, 7 h P
12.2 Fixing of knobs, push buttons, keys and levers None N
12.3 Remote controls with hazardous live parts No remote control with live N
12.4 Drawers (pull test 50 N, 10 s) No drawers N
12.5 Antenna coaxial sockets providing isolation Not exist N
12.6 Telescoping or rod antennas construction Not exist N

TRF No. IECEN60065G


Page 13 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

12.6.1 Telescoping or rod antennas securement N

13 CLEARANCE AND CREEPAGE DISTANCES


13.1 Clearances in accordance with 13.3 P
Creepage distances in accordance with 13.4 P
13.2 Determination of operating voltage (see appended table) P
13.3 Clearances (see appended table) P
13.3.1 General P
13.3.2 Circuits conductively connected to the mains - 2 N for internal parts P
comply with table 8 and, where applicable, table 9 - 30 N for external parts
13.3.3 Circuits not conductively connected to the mains P
comply with table 10
13.3.4 Measurement of transient voltages N
13.4 Creepage distances CTI > 100 P
(see appended table)
Creepage distances greater than table 11 minima (see appended table) P
13.5 Printed boards N
13.5.1 Clearances and creepage distances between N
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
13.5.2 Type B coated printed circuit boards complying No coated printed circuit N
with IEC 60664-3 (basic insulation only) boards
13.6 Conductive parts along uncemented joints N
clearances and creepage distances comply with
13.3 and 13.4
Conductive parts along reliably cemented joints N
comply with 8.8
Temperature cycle test and dielectric strength test N
13.7 Enclosed, enveloped or hermetically sealed parts: N
not conductively connected to the mains:
clearances and creepage distances as in table 12
13.8 Parts filled with insulating compound, meeting the Approved Optocoupler used. P
requirements of 8.8

TRF No. IECEN60065G


Page 14 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

14 COMPONENTS
14.1 Resistors P
a) Resistors between hazardous live parts and No such components N
accessible metal parts
b) Resistors, other than between hazardous live Evaluated in certified power N
parts and accessible parts supply board(LGP32-11P)
(see appended table 14)
b) Resistors separately approved .......................... : R100 P
Evaluated in certified power
supply board(LGP32-11P)
14.2 Capacitors and RC units P
Capacitors separately approved Evaluated in certified power P
supply board(LGP32-11P)
14.2.1 Y capacitors tested to IEC 60384-14, 2nd edition .. : Evaluated in certified power P
supply board(LGP32-11P)
14.2.2 X capacitors tested to IEC 60384-14, 2nd edition .. : Evaluated in certified power P
supply board(LGP32-11P)
14.2.3 Capacitors operating at mains frequency but not Not exist N
connected to the mains: tests for X2 ..................... :
14.2.5 a) Capacitors with volume exceeding 1750 mm³, Evaluated in certified power P
where short-circuit current exceeds 0,2 A: supply board(LGP32-11P)
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
b) Capacitors with volume exceeding 1750 mm³, Evaluated in certified power P
mounted closer to a potential ignition source than supply board(LGP32-11P)
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
Shielded by a barrier per Table 21 or metal ........... : N
14.3 Inductors and windings P
Comply with IEC 61558-1, IEC 61558-2 N
(as relevant) and clause 20.1.4
14.3.1 Transformers and inductors marked with Evaluated in certified power P
manufacturer’s name and type .............................. : supply board(LGP32-11P)
Transformers and inductors separately approved . : No N
14.3.2 General P
Insulation material complies with clause 20.1.4 Isolating transformer P
14.3.3 Constructional requirements (complete appended P
tables or include manufacturers constructional
insulation descriptions)

TRF No. IECEN60065G


Page 15 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

14.3.3.1 Clearances and creepage distances comply with P


clause 13
14.3.3.2 Transformers meet the constructional P
requirements
14.3.4.1 Class II transformers have adequate separation Evaluated in certified power P
between hazardous live parts and accessible parts supply board(LGP32-11P)
(double or reinforced insulation)
Coil formers and partition walls = 0.4 mm Evaluated in certified power P
supply board(LGP32-11P)
14.3.4.2 Class I transformers, with basic insulation and No Class I transformer N
protective screening only if all 7 conditions of
14.3.4.2 are met
14.3.4.3 Separating transformers with at least basic No separating types N
insulation
14.3.5.1 Class II transformers have adequate insulation Evaluated in certified power P
between hazardous live parts and accessible parts supply board(LGP32-11P)
(double or reinforced insulation)
Coil formers and partition walls = 0.4 mm Evaluated in certified power P
supply board(LGP32-11P)
14.3.5.2 Class I transformers have adequate insulation No Class I transformer N
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Winding wires connected to protective earth have N
adequate current-carrying capacity
14.4 High voltage components N
High-voltage components and assemblies: No high voltage components N
U > 4 kV (peak) separately approved
Component meets category V-1 of IEC 60707 N
14.4.1 High voltage transformers and multipliers tested as N
part of the submission
14.4.2 High voltage assemblies and other parts tested as N
part of the submission
14.5 Protective devices P
Protective devices used within their ratings F100, F501 P
External clearances and creepage distances meet Certified fuses used. P
requirement of clause 13 for the voltage across the
device when opened
14.5.1.1 a) Thermal cut-outs separately approved No thermal cut-outs N

TRF No. IECEN60065G


Page 16 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

b) Thermal cut-outs tested as part of the N


submission
14.5.1.2 a) Thermal links separately approved No thermal links N
b) Thermal links tested as part of the submission N
14.5.1.3 Thermal devices re-settable by soldering No thermal devices N
14.5.2.1 Fuse-links in the mains circuit according to IEC Evaluated in certified power P
60127 supply board(LGP32-11P)
14.5.2.2 Correct marking of fuse-links adjacent to holder ... : Evaluated in certified power P
supply board(LGP32-11P)
14.5.2.3 Not possible to connect fuses in parallel ............... : No P
14.5.2.4 Not possible to touch hazardous live parts when Tools are required P
replacing fuse-links without the use of a tool ......... :
14.5.3 PTC thermistors comply with IEC 60730-1 No PTC-S thermistors N

PTC devices (15 W) category V-1 or better N


14.5.4 Circuit protectors have adequate breaking capacity No such components N
and their position is correctly marked
14.6 Switches N
14.6.1 a) Separate testing to IEC 61058 including: Switch not provided N
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
V-0 compliance with annex G, G.1.1 and
Peak inrush rating of switch
Measured/calculated
inrush…………………………:
14.6.1 b) Tested in the apparatus: N
Switch controlling > 0.2A with open contact voltage N
> 35 V (peak)/24 V dc complying with 14.6.3,
14.6.4 and V-0 in annex G, G.1.1
Switch controlling > 0.2A with open contact voltage N
< 35 V (peak)/24 V dc complying with 14.6.3 and
V-0 in annex G, G.1.1
Switch controlling = 0.2A with open contact voltage N
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
14.6.2 Switch tested to 14.6.1 b) constructed to IEC N
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation

TRF No. IECEN60065G


Page 17 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

14.6.3 Switch tested to 14.6.1 b) compliant with IEC N


61058-1 subclause 16.2.2 d), l) and m) not
attaining excessive temperatures in use
14.6.4 Switch tested to 14.6.1 b) has adequate dielectric N
strength
14.6.5 Mains switch controlling mains socket outlets No socket outlets N
additional tests to IEC 60058-1
Socket outlet current marking correct N
14.7 Safety interlocks N
Safety interlocks to 2.8 of IEC 60950 No safety interlock N

14.8 Voltage setting devices N


Voltage setting device not likely to be changed No voltage setting devices N
accidentally
14.9 Motors No motors N
14.9.1 Endurance test on motors N
Motor start test N
Dielectric strength test N
14.9.2 Not adversely affected by oil or grease etc. N
14.9.3 Protection against moving parts N
14.9.4 Motors with phase-shifting capacitors, three-phase N
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
14.10 Batteries No batteries N
14.10.1 Batteries mounted with no risk of accumulation of N
flammable gases
14.10.2 No possibility of recharging non-rechargeable N
batteries
14.10.3 Recharging currents and times within N
manufacturers limits
Lithium batteries discharge and reverse currents N
within the manufacturers limits

14.10.4 Battery mould stress relief N


14.10.5 Battery drop test N
14.11 Optocouplers P
Optocouplers comply with Cl. 8 P
Internal and external dimensions to 13.1. or Evaluated in certified power P
alternatively 13.6 (jointed insulation) supply board(LGP32-11P)

TRF No. IECEN60065G


Page 18 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

14.12 Surge suppression varistors P


Comply with IEC 61051-2 Evaluated in certified power P
supply board(LGP32-11P)
Not connected between mains and accessible N
parts except for earthed parts of permanently
connected apparatus
Complies with the current pulse, fire hazard and N
thermal stress requirements of 14.12

15 TERMINALS
15.1.1 Mains plug, appliance inlet, interconnection (see appended table 14) P
couplers and mains socket-outlet meet the
appropriate standard
Overloading of plugs or appliance inlets prevented N
if the apparatus has mains socket outlets
Overloading of internal wiring prevented if the N
apparatus has mains socket outlets
15.1.2 Connectors for antenna, earth, audio, video or data: P
No risk of insertion in mains socket-outlets P
No risk of insertion into audio or video: outlets No live terminals and symbol N
marked with the symbol of 5.2
15.1.3 Output terminals of a.c. adaptors or similar devices Not exist N
not compatible with household mains socket-
outlets
15.2 Provision for protective earthing P
Accessible conductive parts of Class I equipment Complied P
reliably connected to earth terminal, within
equipment
Protective earth conductors correctly coloured Green / Yellow wire used P
Equipment with non-detachable mains cord Detachable mains cord used N
provided with separate protective earth terminal
near mains input
Earthing connection of parts removable by hand. N
Protective earth terminal resistant to corrosion P
Earth resistance test: < 0,1 Ω at 25 A ................... : < 0.009 Ω P
15.3 Terminals for external flexible cords and for No such terminals N
permanent connection to the mains supply
15.3.1 Adequate terminals for connection of permanent No permanent wiring N
wiring

TRF No. IECEN60065G


Page 19 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

15.3.2 Reliable connection of non-detachable cords: Detachable cord provided N


Not soldered to conductors of a printed circuit N
board
Adequate clearances and creepage distances N
between connections should a wire break away
Wire secured by additional means to the conductor N
15.3.3 Screws and nuts clamping conductors have No screw terminal N
adequate threads: ISO 261, ISO 262 or similar
15.3.4 Soldered conductors wrapped around terminal N
prior to soldering or held in place by additional
means
Clamping of conductor and insulation if not N
soldered or held by screws
15.3.5 Terminals allow connection of appropriate cross- N
sectional area of conductors, for the rated current
of the equipment
15.3.6 Terminals to 15.3.3 have sizes required by N
table 16
15.3.7 Terminals clamp conductors between metal and N
have adequate pressure
Terminals designed to avoid conductor slipping out N
when tightened or loosened
Terminals adequately fixed to avoid loosening N
when the clamping is tightened or loosened and
stress on internal wiring is avoided
15.3.8 Terminals carrying a current more than 0,2 A: N
contact pressure not transmitted by insulating
material except ceramic
15.3.9 Termination of non-detachable cords: wires N
terminated near to each other
Terminals located and shielded: test with 8 mm N
strand
15.4 Devices forming a part of the mains plug No device forming a part of the N
mains plug
15.4.1 No undue strain on mains socket-outlets N
15.4.2 Device complies with standard for dimensions of N
mains plugs
15.4.3 Device has adequate mechanical strength (tests N
a,b,c)

TRF No. IECEN60065G


Page 20 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

16 EXTERNAL FLEXIBLE CORDS


16.1 Mains cords sheathed type, complying with PVC sheathed type used P
IEC 60227 for PVC or IEC 60245 for synthetic
(see appended table 14)
rubber cords ............................................................ :
Non-detachable cords for Class I have Detachable cord used N
green/yellow core for protective earth
16.2 Mains cords conductors have adequate cross- 3 X 1.0 mm2 P
sectional area for rated current consumption of the
equipment
16.3 a) Flexible cords not complying with 16.1, used for No interconnection cords N
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
b) Flexible cords not complying with 16.1, N
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
16.4 Flexible cords used for connection between No interconnection cords N
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
16.5 Adequate strain relief on external flexible cords Detachable cord used N
Not possible to push cord back into equipment N
Strain relief device unlikely to damage flexible cord N
For mains cords of Class I equipment, hazardous N
live conductors become taut before earth
conductor
16.6 Apertures for external flexible cord: no risk of N
damage to the cord during assembly or movement
in use
16.7 Transportable musical instruments and amplifiers Not transportable N
fitted with detachable cord set with appliance inlet
to IEC 60320-1
Transportable musical instruments and amplifiers N
fitted with detachable cord sets or with means of
stowage to protect the cord

TRF No. IECEN60065G


Page 21 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

17 ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS


17.1 Torque test to table 20: P
- screws into metal: 5 times Dia. 3.8 mm: 1.2 Nm tested P
- screws into non-metallic material: 10 times Dia. 2.9 mm : 0.5 Nm tested P
17.2 Correct introduction into female threads in non- P
metallic material
17.3 Cover fixing screws: captive N
Non-captive fixing screws: no hazard when Tested by length of 38 mm, 29 P
replaced by a screw whose length is 10 times its mm : > 6.0 mm
diameter
17.4 No loosening of conductive parts carrying a current P
> 0,2 A
17.5 Contact pressure not transmitted through plastic P
other than ceramic for connections carrying a
current > 0,2 A
17.6 Stranded conductors of flexible supply cords Appliance inlet used N
carrying a current > 0,2 A with screw terminals not
consolidated by solder
17.7 Cover fixing devices other than screws have No cover fixing device N
adequate strength and their positioning is
unambiguous
17.8 Fixing devices for detachable legs or stands P
provided
17.9 Internal pluggable connections, affecting safety, 2 N tested P
unlikely to become disconnected

TRF No. IECEN60065G


Page 22 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

18 MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST


THE EFFECTS OF IMPLOSION
Picture tube separately approved to IEC 61965: No picture tube N
Picture tube separately approved to 18.1 ............... N
18.1 Picture tubes > 16 cm intrinsically protected N
Non-intrinsically protected tubes > 16 cm used with N
protective screen
Protective film as part of implosion protection: N
edges covered by enclosure
18.2 Intrinsically protected tubes: tests on 12 samples N
18.2.1 Samples subject to ageing: 6 N
18.2.2 Samples subject to implosion test: 6 N
18.2.3 Samples subject to mechanical strength test (steel N
ball): 6
18.3 Non-intrinsically protected tubes tested to 18.3 N

19 STABILITY AND MECHANICAL HAZARDS


Mass of the equipment exceeding 7 kg ................. : Mass : 9.6 kg P
Apparatus intended to be fastened in place – N
suitable instructions
19.1 Test on a plane, inclined at 10o to the horizontal Stable P
19.2 100 N force applied vertically downwards Stable P
19.3 100 N force, or 13% of weight, applied horizontally Stable P
to point of least stability.
19.4 Edges or corners not hazardous No hazard : smoothed and P
rounded
19.5 Glass surfaces with an area exceeding 0,1 m² or The glass is protected with thin P
maximum dimension > 450 mm, pass the test of film.
19.5.1
19.6 Wall or ceiling mountings adequate N

TRF No. IECEN60065G


Page 23 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

20 RESISTANCE TO FIRE
20.1 Electrical components and mechanical parts P
a) Exemption for components contained in an P
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
b) Exemption for small components as defined in N
20.1 mounted on a board of flammability category
of V-1 to IEC 60695-11-10
20.1.1 Electrical components meet the requirements of P
Clause 14 or 20.1.4
20.1.2 Insulation of internal wiring working at voltages Electrical components comply P
> 4 kV or leaving an internal fire enclosure, not with flammability requirements
contributing to the spread of fire in clause 14.
20.1.3 Material of printed circuit boards on which the P
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
Material of printed circuit boards on which the PCB : V-0 used P
available power exceeds 15 W at a voltage >400 V
(see appended table 14)
(peak) a.c. or d.c. meets V-0 to IEC 60707
20.1.4 Components and parts not covered by 20.1.1, PCB : V-0 used P
20.1.2 and 20.1.3 (other than fire enclosures)
(see appended table 14)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
Components and parts as above but shielded from N
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
Apparatus with voltages > 4 kV under normal N
conditions, and distances to enclosure exceed
those specified by Table 21, HB40 min enclosure
20.2 Fire enclosure N
20.2.1 Potential ignition sources with open circuit voltage < 4 kV N
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
20.2.2 Internal fire enclosures with openings not N
exceeding 1 mm in width and with openings for
wires completely filled
20.2.3 Requirements of 20.2.1 and 20.2.2 met by an N
internal fire enclosure

TRF No. IECEN60065G


Page 24 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

A APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH


PROTECTION AGAINST SPLASHING WATER
A.5.1 j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not N
apply
A.10.2.1 Enclosure provides protection against splashing N
water
A.10.2.2 Humidity treatment carried out for 7 days N

B APPENDIX B, APPARATUS TO BE CONNECTED TO THE


TELECOMMUNICATION NETWORKS
Complies with IEC 62151 clause 1 N
Complies with IEC 62151 clause 2 N
Complies with IEC 62151 clause 3 but with 3.5.4 N
modified to 2.4.10 of this standard
Complies with IEC 62151 clause 4 but with 4.1.2, N
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
Complies with IEC 62151 clause 5 but with 5.3.1 N
modified in accordance with annex B of this
standard
Complies with IEC 62151 clause 6 N
Complies with IEC 62151 clause 7 N
Complies with IEC 62151 annex A, B and C N

L ANNEX L, ELECTRONIC FLASH APPARATUS FOR PHOTOGRAPHIC N


PURPOSES
L.5.4 Battery chargers and supply apparatus marked N
with model number.
L7.1.5 Lithium batteries: temperature rise (Normal) N
L.9.1.1 Flash synchroniser terminals not hazardous live. N
L.11.2.6 Lithium batteries: temperature rise (Fault). N
L.14.6.6 Peak surge current and rated mains current not to N
exceed mains switch current rating

TRF No. IECEN60065G


Page 25 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

32 inch (With panel T315HW04)


7.1 TABLE: temperature rise measurements P
Power consumption in the OFF/Stand-by………..: Stand-by mode (0.24 W) —
Position of the functional switch (W) ...................... : - —

Cond. Un (V) Hz In (A) Pn (W) V out Pout (W) Operating Condition


1 90 50 1.11 100 -
2 100 50 0.98 99 -
3 240 50 0.42 97.2 -
Main Left - Contrast, Brightness, Color,
4 264 50 0.39 97.0 - & Right : Tint Max
5 90 60 1.12 100 - 1.26 W & - 1 kHz sine-wave 1/8 W audio
1.26 W input
6 100 60 1.0 100 -
7 240 60 0.43 97.3 -
8 264 60 0.40 97.1 -

Loudspeaker impedance (Ω) ................................. : 8 —


Several loudspeaker systems Stereo N
Marking of loudspeaker terminals N
Temperature Rise dT of Part dT (K) required dT (K)
Moderate /
Tropical
Test Condition No. No 5 No 8 No 8(BL) -

LF101 coil 20.8 9.4 19.9 85/75

LF102 coil 16.2 9.7 19.1 85/75

L600 coil 28.5 18.5 27.5 85/75

L600 core 23.3 16.1 25.1 -

T501 coil 26.0 25.5 33.6 75/65

T501 core 26.2 25.6 32.9 -

T101 coil 42.2 43.0 52.3 75/65

T101 core 43.3 44.1 53.2 -

T103 coil 23.3 26.0 31.5 75/65

T110 coil 42.0 44.7 50.3 75/65

HS51 29.1 15.6 24.8 -

HS52 30.7 21.8 33.0 -

TRF No. IECEN60065G


Page 26 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

HS53 23.6 23.8 36.2 -

HS54 36.2 35.5 48.4 -

Back cover(outer) 3.4 6.4 11.0 60/50

Screen 11.9 14.1 15.5 60/50

Ambient 27.6 25.4 24.7 -


Winding temperature rise measurements
Ambient temperature t1 (oC) ...................................: —
o
Ambient temperature t2 ( C) ...................................: —

Temperature rise dT of winding: R1 (Ω) R2 (Ω) dT (K) Limit dT (K) Insulation


dT = (R2 – R1) x (234.5 + t1) – (t2 – t1) class
R1
- - - - - -

32 inch (With panel T315XW03)


7.1 TABLE: temperature rise measurements P
Power consumption in the OFF/Stand-by……….: Stand-by mode (0.24 W) —
Position of the functional switch (W) ...................... : - —

Cond. Un (V) Hz In (A) Pn (W) V out Pout (W) Operating Condition


1 90 50 1.15 104.4 -
2 100 50 1.02 103.6 -
3 240 50 0.44 100.5 -
Main Left - Contrast, Brightness, Color,
4 264 50 0.41 100.2 - & Right : Tint Max
5 90 60 1.17 104.6 - 0.90 W & - 1 kHz sine-wave 1/8 W audio
0.90 W input
6 100 60 1.03 103.7 -
7 240 60 0.45 100.7 -
8 264 60 0.42 100.4 -

Loudspeaker impedance (Ω) ................................. : 8 —


Several loudspeaker systems Stereo N
Marking of loudspeaker terminals N
Temperature Rise dT of Part dT (K) required dT (K)
Moderate /
Tropical

TRF No. IECEN60065G


Page 27 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

Test Condition No. No 5 No 8 No 8(BL) -

LF101 coil 21.9 6.4 22.1 85/75

LF102 coil 17.7 6.9 21.3 85/75

L600 coil 31.1 17.0 30.4 85/75

L600 core 25.3 14.1 27.5 -

T101 coil 42.5 40.7 53.4 75/65

T101 core 45.6 43.5 56.3 -

T501 coil 28.0 29.1 38.1 75/65

T501 core 28.2 25.2 38.3 -

T110 coil 48.9 48.4 57.5 75/65

T103 coil 28.7 28.5 36.1 75/65

HS1 29.8 13.0 27.0 -

HS2 24.4 18.8 34.6 -

HS3 26.5 22.5 38.5 -

HS4 38.2 34.3 50.6 -

HS6 27.7 24.9 40.4 -

Back cover(outer) 4.4 2.9 12.7 60/50

Screen 14.4 13.5 18.1 60/50

Ambient 26.9 26.6 24.5 -


Winding temperature rise measurements
Ambient temperature t1 (oC) ...................................: —
o
Ambient temperature t2 ( C) ...................................: —

Temperature rise dT of winding: R1 (Ω) R2 (Ω) dT (K) Limit dT (K) Insulation


dT = (R2 – R1) x (234.5 + t1) – (t2 – t1) class
R1
- - - - - -

TRF No. IECEN60065G


Page 28 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

32 inch (With panel HV320WXC)


7.1 TABLE: temperature rise measurements P
Power consumption in the OFF/Stand-by……….: Stand-by mode (0.24 W) —
Position of the functional switch (W) ...................... : - —

Cond. Un (V) Hz In (A) Pn (W) V out Pout (W) Operating Condition


1 90 50 1.12 104.8 -
2 100 50 1.01 104.9 -
3 240 50 0.44 102.2 -
Main Left - Contrast, Brightness, Color,
4 264 50 0.40 102.1 - & Right : Tint Max
5 90 60 1.14 105 - 0.90 W & - 1 kHz sine-wave 1/8 W audio
0.90 W input
6 100 60 1.02 105 -
7 240 60 0.45 102.3 -
8 264 60 0.41 102.1 -

Loudspeaker impedance (Ω) ................................. : 8 —


Several loudspeaker systems Stereo N
Marking of loudspeaker terminals N
Temperature Rise dT of Part dT (K) required dT (K)
Moderate /
Tropical
Test Condition No. No 5 No 8 No 8(BL) -

LF101 coil 23.2 7.8 20.4 85/75

LF102 coil 17.5 8.0 20.4 85/75

LF102 core 19.0 9.0 20.9 -

L600 coil 26.6 15.6 26.8 85/75

L600 core 24.4 14.4 25.7 -

T101 coil 23.8 21.5 33.5 75/65

T101 core 24.1 21.9 33.2 -

T501 coil 40.4 38.2 50.4 75/65

T501 core 40.2 38.4 50.7 -

HS1 29.0 12.9 25.2 -

HS2 19.9 19.2 32.3 -

HS3 23.7 20.2 35.1 -

HS4 33.9 30.7 46.3 -

TRF No. IECEN60065G


Page 29 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

HS6 25.6 23.2 37.9 -

T1 coil 51.7 52.2 64.6 75/65

T8 coil 47.1 46.2 52.5 75/65

Back cover(Inner) 4.8 4.5 13.1 60/50

Back cover(Outer) 4.1 3.6 10.2 60/50

Screen 14.3 14.9 16.5 60/50

Ambient 23.8 24.3 25.7 -


Winding temperature rise measurements
Ambient temperature t1 (oC) ...................................: —
o
Ambient temperature t2 ( C) ...................................: —

Temperature rise dT of winding: R1 (Ω) R2 (Ω) dT (K) Limit dT (K) Insulation


dT = (R2 – R1) x (234.5 + t1) – (t2 – t1) class
R1
- - - - - -

26 inch (With panel T260XW04)


7.1 TABLE: temperature rise measurements P
Power consumption in the OFF/Stand-by……….: Stand-by mode (0.24 W) —
Position of the functional switch (W) ...................... : - —

Cond. Un (V) Hz In (A) Pn (W) V out Pout (W) Operating Condition


1 90 50 0.86 77.7 -
2 100 50 0.76 77.1 -
3 240 50 0.34 75.6 -
Main Left - Contrast, Brightness, Color,
4 264 50 0.32 75.5 - & Right : Tint Max
5 90 60 0.87 77.8 - 0.90 W & - 1 kHz sine-wave 1/8 W audio
0.90 W input
6 100 60 0.78 77.3 -
7 240 60 0.35 75.8 -
8 264 60 0.33 75.7 -

Loudspeaker impedance (Ω) ................................. : 8 —


Several loudspeaker systems Stereo N
Marking of loudspeaker terminals N

TRF No. IECEN60065G


Page 30 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

Temperature Rise dT of Part dT (K) required dT (K)


Moderate /
Tropical
Test Condition No. No 5 No 8 No 8(BL) -

LF101 coil 21.1 9.5 18.7 85/75

LF102 coil 16.8 9.5 18.9 85/75

L600 coil 25.0 16.4 26.3 85/75

L600 core 21.0 13.7 24.1 -

T101 coil 36.2 35.1 44.1 75/65

T101 core 39.1 38.0 46.2 -

T501 coil 30.4 29.9 40.4 75/65

T501 core 29.4 28.7 39.2 -

T103 coil 40.0 39.9 46.4 75/65

T110 coil 24.4 24.1 30.2 75/65

HS1 25.0 12.0 22.0 -

HS2 19.7 21.6 32.3 -

HS3 23.4 20.6 32.1 -

HS4 32.0 30.4 41.7 -

HS6 30.2 29.0 39.8 -

Back cover(outer) 10.3 8.8 11.3 60/50

Screen 15.4 15.6 18.5 60/50

Ambient 26.6 25.9 27.1 -


Winding temperature rise measurements
Ambient temperature t1 (oC) ...................................: —
Ambient temperature t2 (oC) ...................................: —

Temperature rise dT of winding: R1 (Ω) R2 (Ω) dT (K) Limit dT (K) Insulation


dT = (R2 – R1) x (234.5 + t1) – (t2 – t1) class
R1
- - - - - -

TRF No. IECEN60065G


Page 31 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

7.2 TABLE: softening temperature of thermoplastics N

Temperature T of part T – normal condi- T – fault condi- T softening


tions (oC) tions (oC) (oC)
- - - -

9.1 Shock Hazard P


Under normal operating conditions: > 35Vpk ac / 60V dc

Notes: Reference Annex D

CLASS I: (single phase)

AC DC
U1: 0.870 Vpk Arms U1: V mA

U2: 0.204 Vpk Arms U2: V mA

10.3 TABLE: Insulation Resistance Measurements P

Insulation resistance R between: R (MΩ) Required R (MΩ)


Between mains poles > 100 2
Between parts separated by basic or supplementary insulation > 100 2
Between parts separated by double or reinforced insulation > 100 4

10.3 TABLE: Electric Strength Measurements P

Test voltage applied between: Test voltage (V) Breakdown


Mains poles 2,120 Vpeak No
Between parts separated by basic or supplementary insulation 2,120 Vpeak No
Between parts separated by double or reinforced insulation 4,240 Vpeak No

TRF No. IECEN60065G


Page 32 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

11.2 TABLE: summary of fault condition tests P


Voltage (V) 0.9 or 1.1 times rated voltage ............. : 264 V -
Ambient temperature (ºC) ...................................... : 25.3 -
No Component Fault Test Test Current Result
No voltage time consumption
(V) (A)

Evaluated in certified power supply board(LGP32-11P)

S/C: Short Circuit, NCD : No Component Damage, N/H : No Hazard

Winding temperature rise measurements

Ambient temperature t1 (C°) .................................. : -

Ambient temperature t2 (°C) .................................. : -

TRF No. IECEN60065G


Page 33 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

(LGP32-11P Power Supply Board)


Clause 13.3, 13.4 Clearances and Creepage distances
Working voltage(V) Clearances Creepage
Position/Location
Required Measured Required Measured
Peak r.m.s.
(mm) (mm) (mm) (mm)

SK100 348 240 2.0 3.0 2.5 3.0

CY101 348 240 2.0 3.3 2.5 3.3

CY103 348 171 2.0 3.3 2.5 6.3

IC101 pin 1 IC102 pin 3 360 179 2.0 7.5 2.5 7.5

IC102 pin 4 368 183 2.0 7.5 2.5 7.5

IC101 pin 2 IC102 pin 3 356 178 2.0 7.5 2.5 7.5

IC102 pin 4 364 183 2.0 7.5 2.5 7.5

IC501 pin 1 IC502 pin 3 352 174 2.0 7.5 2.5 7.5

IC502 pin 4 348 171 2.0 7.5 2.5 7.5

IC501 pin 2 IC502 pin 3 348 173 2.0 7.5 2.5 7.5

IC502 pin 4 348 171 2.0 7.5 2.5 7.5

IC502 pin 1 IC503 pin 3 332 162 2.0 7.5 2.5 7.5

IC503 pin 3 332 162 2.0 7.5 2.5 7.5

IC502 pin 2 IC503 pin 3 332 162 2.0 7.5 2.5 7.5

IC503 pin 4 336 162 2.0 7.5 2.5 7.5

T101, pin 2 T101, pin 7 410 244 4.2 9.5 5.2 12.5

T101, pin 8 430 262 4.2 9.5 5.2 12.5

T101, pin 9 440 272 4.2 9.5 5.2 12.5

T101, pin 10 400 238 4.2 9.5 5.2 12.5

T101, pin 11 420 256 4.2 9.5 5.2 12.5

T101, pin 5 T101, pin 7 330 185 4.2 9.5 5.2 12.5

T101, pin 8 310 174 4.2 9.5 5.2 12.5

TRF No. IECEN60065G


Page 34 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

T101, pin 9 320 174 4.2 9.5 5.2 12.5

T101, pin 10 340 181 4.2 9.5 5.2 12.5

T101, pin 11 310 175 4.2 9.5 5.2 12.5

T501, pin 1 T501, pin 8 440 317 4.4 8.0 7.2 8.0

T501, pin 11 410 317 4.4 8.0 7.2 8.0

T501, pin 3 T501, pin 8 560 343 4.4 8.0 7.2 8.0

T501, pin 11 560 344 4.4 8.0 7.2 8.0

T501, pin 6 T501, pin 8 460 181 4.4 8.0 7.2 8.0

T501, pin 11 480 182 4.4 8.0 7.2 8.0

T501, pin 7 T501, pin 8 360 176 4.4 8.0 7.2 8.0

T501, pin 11 360 175 4.4 8.0 7.2 8.0

TRF No. IECEN60065G


Page 35 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

14 TABLE: list of critical components and materials P

Object / part No. manufacturer / Type / model technical data standard mark(s) of
trademark conformity1)

Power supplies LG Electronics LGP32-11P 100-240 Vac, IEC 60065 TUV CB


Switching Mode 50/60 Hz, :2001+Amd1
3.0 A,
Power Supply 2005
Class I
Enclosure Various Various Minimum Flame UL UL
Material Class HB
Appliance inlet Dong il Tech. IF7-E06AEW 6 A, 250 V IEC 60939 VDE
With EMI filter IF7-N06AEW
IF-N06AEW
Hon Hai Precision. 4M1600C100WS
4M1600C110WS
PCB (various) (various) V-0, min 105 oC UL UL
(for PSU)
Power plug I-SHENG SP023 10/16 A, 250 V IEC 60884-1 SEMKO
Volex MP5004 13 A, 250 V BS1363 ASTA
LEONI 300 16 A, 250 V IEC 60884-1 DEMKO
Various Various Various Various *
* : According to the manufacturer’s declaration, the unit will be supplied with a power
attachment cord plug and appliance connector which meet the national requirements
and which have been approved to relevant national and international standards.

Appliance I-SHENG IS-15 10 A, 250 V IEC 60320-1 SEMKO


connector
Volex V1625 10 A, 250 V IEC 60320-1 SEMKO
LEONI 250F 10 A, 250 V EN 60320-1 KEMA

Various Various Various Various *


Mains cord Kuk je Tong Shin H05VV-F 3 X 0.75 mm2 or - VDE, SEMKO
3 X 1 mm2

LEONI H05VV-F 3 X 0.75 mm2 or - VDE


3 X 1 mm2

Various Various Various Various *

TRF No. IECEN60065G


Page 36 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

Object / part No. manufacturer / Type / model technical data standard mark(s) of
trademark conformity1)

* : According to the manufacturer’s declaration, the unit will be supplied with a power
attachment cord plug and appliance connector which meet the national requirements
and which have been approved to relevant national and international standards.
LCD Panel AU Optronics T260XWYY 26 inch IEC 60065: TUV
Corporation (Y=0-9, A-Z or 2001+A1
blank)
T315HWYY 32 inch IEC 60065: TUV
(Y=0-9, A-Z or 2001+A1
blank)
T315XWYY 32 inch IEC 60065: TUV
(Y=0-9, A-Z or 2001+A1
blank)
IPS VVX32H109G00 32 inch IEC 60065 TUV

HEFEI BOE HV32#W##-### 32 inch IEC 60950- DEMKO


OPTOELECTRO (#=0-9, A-Z or 1:2005 2nd
NICS blank)
1
) an asterisk indicates a mark which assures the agreed level of surveillance

14.3.3 Transformer construction requirements P


Transformer Part No. Operating voltage Clearance distance Creepage distance Dielectric
/ model no. strength
Up U r.m.s. Required Measured Required Measured
[mm] [mm] [mm] [mm]
test
[Vpeak] [V]

Evaluated in certified power supply board(LGP32-11P)

Transformer Part No. Category Construction


/ model no.

Evaluated in certified power supply board(LGP32-11P)

TRF No. IECEN60065G


Page 37 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

Group and national deviations for EN60065

ZB ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS


2.6.1 DK: certain types of Class I apparatus, see 15.1.1, N
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
13.3.1 NO: In Norway, due to IT power distribution system N
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
15.1.1 DK: mains cord for single-phase equipment having N
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
DK: Class I equipment with socket-outlets with N
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
DK: socket-outlets for providing power to Class II N
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 179
of EN 60 065:2002 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
DK: mains socket-outlets with earthing contact N
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
GB: equipment fitted with a flexible cable or cord N
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
IE: equipment fitted with a flexible cable or cord N
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the
following amendments:
- dimensions 2,5 A, 250 V socket-outlets shall N
comply with Standard Sheet I page 180 of
EN 60 065:2002
- mechanical strength 2,5 A, 250 V socket-outlets N
tested as specified in EN 60 065, 12.1.3

TRF No. IECEN60065G


Page 38 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

- protecting rim also tested N


NO: method b) of 8.1 is not permitted. Double or N
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
J.2 NO: In Norway, due to IT power distribution system N
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.

ZC ANNEX ZC TO EN 60 065, A-DEVIATIONS


5 DE: additional markings required in German language: N
- cathode ray tubes with an accelerating voltage N
between 20 kV and 30 kV (marking on the tube)
- TV receivers whose picture tube has an N
accelerating voltage between 20 kV and 30 kV
- TV receivers whose picture tube has an N
accelerating voltage greater than 30 kV
- TV receivers whose picture tube has an N
accelerating voltage less than 20 kV
5.1 IT: additional markings on the outside of the TV N
receiver in Italian language
IT: user instructions in Italian language including a N
conformity declaration
IT: certification number on the back cover N
14 SE: Switches containing mercury such as N
thermostats, relays and level controllers are not
allowed.

TRF No. IECEN60065G


Page 39 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

Group and national deviations for EN 60065+A1 : 2006

5.1 i) Replace the note by: N


NOTE: For RATED POWER CONSUMPTION N
measurements of TVs reference is made to EN
62087. Measurements
are done in the ON (play) operating mode.
5.4.1 Add the following indent: N
za) A warning that excessive sound pressure N
from earphones and headphones can cause
hearing loss.
6.1 Replace the subclause by: N
6.1 Ionizing radiation No ionizing radiation N
Equipment that might produce ionizing radiation N
is checked by measuring the amount of radiation.
The amount of radiation is determined by means N
of a radiation monitor of the ionizing chamber
type with an effective area of 1 000 mm2 or by
measuring equipment of other types giving
equivalent results.
Measurements are made with the equipment on N
fest operating at the most unfavourable supply
voltage (See 4.2) and with operator controls and
service controls adjusted so as to give maximum
radiation whilst maintaining the equipment
operative for normal use.
Interna1 preset controls not intended to be N
adjusted during the lifetime of the equipment are
not considered to be service controls.
At any point 100 mm from the surface of the N
operator access area, the dose-rate shall not
exceed
1 pSv/h (0, I mR/h)
(see Note). Account shall be taken of the
background level.
NOTE: These values appear in Directive N
96/29/Euratom

TRF No. IECEN60065G


Page 40 of 48 Ref. No. : 10-1330-0817

IEC/EN 60065
Clause Requirement – Test Result - Remark Verdict

National deviations for Singapore

4 All apparatus must be tested to 230 Vac Include 230 Vac P

4.3.13 Apparatus fitted with voltage selector switch must No voltage selector N
be tested as follows:
Connect apparatus to 230 V ac mains with voltage
selector switch to settings not suitable for
operation at 230 V ac.

5.3 Circuit diagrams must be indicated with Schematic included in CB P


component values. report.

Circuit diagrams of electronic modules in the Schematic included in CB P


apparatus must be provided. report.

7.1, 11.2 Permissible temperature rises of 10 K less than Meets tropical limits P
those specified in Table 2 are required.

10.2 Humidity treatment. Adopt the testing conditions 5 days P


designed for tropical conditions.

15.1.1 All Class I apparatus must be fitted with 3-pin Approved P


mains plugs that comply with SS 145/SS 472 that
are registered with the Safety Authority

a) All Class II apparatus must be fitted with 2-pin N


mains plugs (Appendix W) that comply with IEC
83:1975 (Standard C5, Version II) or EN 50075.

b) Class II apparatus that are fitted with 3-pin N


mains plugs must use plugs that comply with SS
145 and registered with the Safety Authority.

15.3 Apparatus ≥ 3 kW must be connected to fixed < 3 kW N


wiring. All connection to fixed wiring must be in
accordance with Code of Practice CP5.

16 Detachable power cord set must be listed in the See table 14 P


test report critical component list.

Misc. Apparatus enclosure which is shaped and Not shaped like toy. P
decorated so that it is likely to be treated as a toy
by children, shall not be accepted for certification
and registration.

TRF No. IECEN60065G


Page 41 of 48 Ref. No. : 10-1330-0817

< Photo 1 >

< Photo 2 >

TRF No. IECEN60065G


Page 42 of 48 Ref. No. : 10-1330-0817

< Photo 3 >

< Photo 4 > 32LK33##

TRF No. IECEN60065G


Page 43 of 48 Ref. No. : 10-1330-0817

< Photo 5 > 32LK33##

< Photo 6 > (Panel HV320WXC)

TRF No. IECEN60065G


Page 44 of 48 Ref. No. : 10-1330-0817

< Photo 7 > (Panel T315XW03)

< Photo 8 > 32LK45##

TRF No. IECEN60065G


Page 45 of 48 Ref. No. : 10-1330-0817

< Photo 9 > 32LK45##

< Photo 10 > (Panel T315HW04)

TRF No. IECEN60065G


Page 46 of 48 Ref. No. : 10-1330-0817

< Photo 11 > 26LK31##

< Photo 12 > 26LK31##

TRF No. IECEN60065G


Page 47 of 48 Ref. No. : 10-1330-0817

< Photo 13 > (Panel T260XW04)

TRF No. IECEN60065G


Page 48 of 48 Ref. No. : 10-1330-0817

< Circuit diagram > (1/1)

TRF No. IECEN60065G