55.000000 <---- Line Temperature (deg. C)


68.950005 <---- Pressure (abs) (bars ) [Must be > 2.1]
114.632797 <---- ID of Relief Valve Orifice (mm.)
250.000000 <---- ID of Relief Valve Piping (mm.)
250.000000 <---- ID of Vent Stack Piping (mm.)
1000.000000 <---- Length of Vent Stack (mm.)
1.270000 <---- Ratio of Gas Specific Heats (k) [Air = 1.4]
500.000000 <---- Gas Constant (R) ( N.m. /Kg./deg.K) [Air =285.2 ]
N <---- Does the Vent Pipe have an Umbrella fitting (Y/N)
N <---- Should CAESAR II size the Vent Stack (Y/N)

Computed Mass Flowrate (Vent gas) ..... (Kg. /hour) 418580.188


Thrust at Valve Pipe/Vent Pipe Interface ... ( N. ) 123906.977
Thrust at Vent Pipe Exit ................... ( N. ) 83841.844
Transient Pressure Rise, Valve Opening (bars ) 14.284
Transient Pressure Rise, Valve Closing (bars ) 10.148
Thermodynamic Entropy Limit (Should be > 1) ...... 1.199
Subsonic Vent Exit Limit (Should be > 1) ...... 0.805
(bars --abs) (mm./s) (deg C)
Valve Orifice Gas Conditions ... (P,Vel,T) 38.0 428788.6 15.9
Vent Pipe Exit Gas Conditions .. (P,Vel,T) 8.2 419014.8 15.9
Subsonic Velocity Gas Conditions (P,Vel,T) 9.0 387640.1 21.6