Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Totally Integrated Power – SIHARBOR

Sustainable power supply


for eco-friendly ports
Shore connection power supply system for ships: SIHARBOR

siemens.com/siharbor
Everything from a single source: The perfectly matched medium-voltage systems provide an efficient solution for ports and ships.

Totally Integrated Power (TIP)

A reliable, highly available, and flexible power supply for industries as well as buildings
and facilities provides the basis for both industrial processes and infrastructure solutions.

Siemens’ solution is Totally Integrated Power (TIP), New challenge in ports


our comprehensive power supply portfolio of software Shipping is booming continuously, and more and more
and hardware products, holistic systems for all voltage cruise liners are docking at ports. Of course, this implies
levels, as well as energy management solutions. TIP problems for the port operators, because the ship also
is closely linked to industrial and building automation has to generate power for onboard equipment, shops
­systems and is integrated into enterprise IT systems. and air conditioning when berthed. This means that
the diesel generators commonly used on board also have
This allows to fully exploit all the optimi­zation potential to run ­permanently in the port. This process generates
of an integrated solution. TIP meets even the toughest large amounts of CO2, NOX and dangerous fine particulate
requirements of supply-critical assets. An extensive ­matter. The emissions of a berthed cruise liner can be
­support throughout the entire lifecycle starting with compared to the environmental pollution of a medium-­
­planning up to services completes our offering. sized city.

With regard to their own employees and the local resi-


dents of the port area, the port operators are determined
to cut back the air and noise pollution. With SIHARBOR,
Siemens offers a power supply solution with numerous
advantages for the respective operators at the ports.

2
Quick and easy connection to the ship via the cable management system

Comprehensive solution with SIHARBOR

Power supply from the public grid – ensured both by the software and by the
Your benefit
Reliable and clean hardware, independently of each other.
SIHARBOR enables the ships to get power The whole shore connection system can • For ships: Reduction of
from the onshore power grid when be remotely controlled from the ship ­maintenance costs and fuel
consumption of the diesel
berthed, so that it will not be necessary without additional qualified personnel.
­generators in the port.
to operate the diesel generators com-
­Discounts for ships using
monly used on board. Thus, SIHARBOR Everything from a single source the shore connection power
provides numerous benefits not only for On request, SIHARBOR can be designed supply system
port operators, but also for ship owners, as a turnkey solution, from planning • For ports: New business
local residents, and the port staff. through system integration (with all opportunities for the port
LV and MV products and switchgear for ­operator by providing power
supply for ships
Safe and easy operation connection to the grid) up to commis-
• For local residents and the
In order to eliminate the residual risk sioning and service. The system can
port staff: Improved quality of
of arcing in the plug-in connection, the optionally be installed in a container life by reduction of emissions,
cable connection to the ship is tested or in already existing buildings. noise and vibrations
at rated voltage with low power before
being connected. On a higher level, the
­SIMATIC S7 control unit with operator
panel monitors the state of the whole
SIHARBOR system centrally. Thereby,
all relevant messages and data can be
indicated, and all operating and safety
functions can be selected. The control
unit ensures that only permissible switch-
ing operations according to IEC/ISO/IEEE
80005 are executed. The personnel who
operates the plug-in connection on shore
and on board is protected by generally
double electrical interlocks. Protection is

3
Power/port
Ship ◼ ON  ◼ OFF
automation
Status: 0 kW
Power/port earthed

Shoreside
automation

Cable isolation
test
Connection
on berth

SIPLINK converter system for network applications in a SIHARBOR solution

Perfectly matched components


for maximum efficiency

Why must the frequency For all voltages and frequencies Compact converter solution
be converted? With its modular concept, the system is with high efficiency
In international maritime traffic, perfectly adapted to all required power The system comprises a variable fre-
around 75 % of all ships are ratings, voltages and frequencies. quency converter, the control system and
equipped with 60 Hz networks. ­SIHARBOR uses an isolating transformer the HMI (Human-Machine Interface). The
However, only 25 % of the coun- to galvanically isolate the ship’s network perfectly matched components provide
tries operate their power grids with
from the onshore power grid and other an efficient solution for ports and ships.
this frequency.
ship networks.
Therefore, the onshore
­frequency must be adjusted to
the onboard frequency in SIPLINK: Siemens Power Link
75 % of the countries. With the SIPLINK is a converter system adapted for
­SIPLINK converter system and the network applications. It can connect two
SINAMICS SM120 CM converters, or more medium-voltage AC networks
ships operating at 50 Hz and at
with different voltages, phase angles and
60 Hz can be supplied.
frequencies. With SIPLINK, the voltage is
adjusted by transformer tap changing
and by modification of the converter out-
put voltage. Thus, any required transfer
voltage to the ship can be implemented.

4
Control Basic Line Active Line Module Recooling
Module Module (M2C) Module

Medium-voltage converter SINAMICS SM120 CM (cabinet modules)

SINAMICS SM120 CM – The reliable medium-voltage


converter for frequency conversion

SINAMICS SM120 CM SINAMICS SM120 CM (cabinet modules)


Your benefit
(cabinet modules) with a multi-level active line module
The SIPLINK system is based on the ensures an excellent performance while • Higher overall efficiency and
­universally applicable SINAMICS con- feeding power into the grid. The con- reduced space requirements
compared to conventional
verter family. By means of the M2C verter is commonly used, apart from
­two-point low-voltage
topology, the medium-voltage converter shore connections, in testing facilities
solutions
­SINAMICS SM120 CM generates a sinu­ and in applications of the marine, energy, • Cable lengths with up to
soidal voltage in many small steps. mining, and steel industry. 1000 m possible – due to the
In this way, the output current attains sinusoidal output voltage of
a ­perfectly sinusoidal wave form, and The modular SINAMICS SM120 CM the M2C technology
in many situations no further filtering ­system combines topologies that have • Low network feedback – due
to the selectable diode infeed
is required. been proven time and again, and have
(12-, 18-, 24-, 36-pulse)
successfully been in operation for several
• Support of selective clearance
The ­SINAMICS SM120 CM medium-volt- years. of short-circuits by overcurrent
age converter is the modular ­system for supply of the M2C-ALM
applications with special requirements.
A wide range of matching components
and functions enables the implementa-
tion of project-specific solutions.

5
Siemens AG
Energy Management
Mozartstrasse 31 c
91052 Erlangen, Germany
www.siemens.com/siharbor

Article no. EMMS-B10001-00-7600


Printed in Germany
TH 260-150155 | WS | 0915
Subject to change without prior notice

© 2015 Siemens. All rights reserved.


The information provided in this brochure contains
descriptions or characteristics of performance which
in case of actual use do not always apply as described
or which may change as a result of further development
of the products. An obligation to provide the respective
characteristics shall only exist if expressly agreed
in the terms of contract.

You might also like