Motors Protection Schedules
Motors Protection Schedules
MCC0001 X
MCC0001 X
A1
MCC0001 X
MCC0001 X
MCC0001 X
A2 MCC0001 X
MCC0001 X
A3 MCC0001
MCC0002 X X
MCC0002 X X
A4
MCC0002 X X
MCC0002 X X
MCC0002 X X
MCC0002 X X
A4
MCC0002 X X
MCC0002 X X
A7 MCC0002 X
A8 MCC0002 X
MCC0002 X
A9
MCC0002 X
MCC0002 X
A9
MCC0002 X
MCC0002 X
A10 MCC0002 X
MCC0002 X
MCC0002 X
A10 MCC0002 X
MCC0002 X
A8 MCC0002 X
A7 MCC0002 X
A7 MCC0002 X
A7 MCC0002 X
A7 MCC0002 X
A7 MCC0002 X
A7 MCC0002 X
A8 MCC0002 X
MCC0002 X
A10 MCC0002 X
MCC0002 X
MCC0002 X
A10 MCC0002 X
MCC0002 X
MCC0002 X
A9
MCC0002 X
A8 MCC0002 X
MCC0002 X X
MCC0002 X X
A4
MCC0002 X X
MCC0002 X X
MCC0002 X X
A5
MCC0002 X X
MCC0003 X X
A6
MCC0003 X X
MCC0003 X
A9
MCC0003 X
MCC0003 X
MCC0003 X
A11
MCC0003 X
MCC0003 X
MCC0003 X
A12 MCC0003 X
MCC0003 X
Moisture Anti- Grundfos IO113 / Grundfos ALR 20
WIO Sensor condensation Start Up DS Rating (A) SM 113 Relay
Sensor heater module relay
X VFD 160
X VFD 160
X VFD 160
X VFD 160
X VFD 160
X VFD 160
X VFD 160
DOL 30
X X VFD 60 X
X X VFD 60 X
X X VFD 60 X
X X VFD 60 X
X X VFD 60 X
X X VFD 60 X
X X VFD 60 X
X X VFD 60 X
X DOL 30 X
X X DOL 30 X
X X DOL 30 X
X X DOL 30 X
X X DOL 30 X
X X DOL 30 X
VFD 50
VFD 50
VFD 50
VFD 50
VFD 50
VFD 50
X X DOL 30 X
X DOL 30 X
X DOL 30 X
X DOL 30 X
X DOL 30 X
X DOL 30 X
X DOL 30 X
X X DOL 30 X
VFD 30
VFD 30
VFD 30
VFD 30
VFD 30
VFD 30
X X DOL 30 X
X X DOL 30 X
X X DOL 30 X
X X VFD 80 X
X X VFD 80 X
X X VFD 80 X
X X VFD 80 X
X X DOL 60 X
X X DOL 60 X
X X VFD 30 X
X X VFD 30 X
X X DOL 30 X
X X DOL 30 X
X DOL 30
X DOL 30
X DOL 30
X DOL 30
X VFD 30
X VFD 30
X VFD 30
Cable sizing /type
Type of installation Area classification Supplier
Power Control
Grundfos 1
Grundfos 1
Outdoor Safe Area
Grundfos 1
Grundfos 1
Grundfos 1
Outdoor Safe Area Grundfos 1
Grundfos 1
Outdoor Safe Area Baldor 2
Grundfos 3
Grundfos 3
Indoor Zone classé
Grundfos 3
Grundfos 3
Grundfos 3
Grundfos 3
Outdoor Safe Area
Grundfos 3
Grundfos 3
Outdoor Safe Area Grundfos 5
Outdoor Safe Area Grundfos 6
Grundfos 6
Outdoor Safe Area
Grundfos 6
Grundfos 6
Outdoor Safe Area
Grundfos 6
Arabian Pumps 7
Outdoor Safe Area Arabian Pumps 7
Arabian Pumps 7
Arabian Pumps 7
Outdoor Safe Area Arabian Pumps 7
Arabian Pumps 7
Outdoor Safe Area Grundfos 6
Outdoor Safe Area Grundfos 5
Outdoor Safe Area Grundfos 5
Outdoor Safe Area Grundfos 5
Outdoor Safe Area Grundfos 5
Outdoor Safe Area Grundfos 5
Outdoor Safe Area Grundfos 5
Outdoor Safe Area Grundfos 6
Arabian Pumps 7
Outdoor Safe Area Arabian Pumps 7
Arabian Pumps 7
Arabian Pumps 7
Outdoor Safe Area Arabian Pumps 7
Arabian Pumps 7
Grundfos 6
Outdoor Safe Area
Grundfos 6
Outdoor Safe Area Grundfos 6
Grundfos 3
Grundfos 3
Outdoor Safe Area
Grundfos 3
Grundfos 3
Grundfos 3
Outdoor Safe Area
Grundfos 3
Grundfos 3
Outdoor Safe Area
Grundfos 3
Grundfos 6
Outdoor Safe Area
Grundfos 6
Arabian Pumps 8
Arabian Pumps 8
Outdoor Safe Area
Arabian Pumps 8
Arabian Pumps 8
Arabian Pumps 9
Outdoor Safe Area Arabian Pumps 9
Arabian Pumps 9
sizing /type
Overal
diametre
Motor Protections Sensors With Local Control Panel (near the motor)
With Local Control Panel (near the motor)
containing : containing :
Anti- - Start pushbutton
- Start pushbutton
Type Motor Starting Type condensation
- Stop pushbutton - Stop pushbutton
PT100 in heater - Switch Selector Local/0/Remote - Switch Selector Local/0/Remote
PTC PT1000 in PT100 in lower Moisture WIO Sensor - Indiction lamp (Run/Stop/Fault)
winding winding Sensor - Indiction lamp (Run/Stop/Fault).
bearing - Speed Control potentiometer (for VFD).
1 DOL X X X X
2 DOL X X X X
3 DOL X X X X X
4 VFD X X X X
5 VFD X X X X X