Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Performance of tracking PV

PVGIS-5 estimates of solar electricity generation


Provided inputs: Simulation outputs Outline of horizon at chosen location:
Latitude/Longitude: 22.300, 70.783 VA*
Horizon: Calculated Slope angle [°]: 22
Database used: PVGIS-SARAH Yearly PV energy production [kWh]: 1975.86
PV technology: Crystalline silicon Yearly in-plane irradiation [kWh/m²]: 2650.39
PV installed: 1 kWp Year-to-year variability [kWh]: 32.3
System loss: 14 % Changes in output due to:
Angle of incidence [%]: -1.84
Spectral effects [%]: 0.02
Temp. and low irradiance [%]: -11.71
Total loss [%]: -25.45

* VA: Vertical axis

Monthly energy output from tracking PV system:

Vertical axis
Month E_m H(i)_m SD_m
January 173.9 225.7 4.4
February 170.3 228.3 7.2
March 197.1 273.2 6.4
April 197.4 274.9 3.0
May 202.1 279.4 3.0
June 155.6 207.5 12.6
July 115.5 149.8 9.0
August 118.0 153.7 14.3
September 144.9 191.4 13.8
October 176.9 238.5 7.5
November 157.8 211.4 11.2
Monthly in-plane irradiation for tracking PV system: December 166.4 216.5 6.1

E_m:Average monthly electricity production from the given system [kWh].


H_m: Average monthly sum of global irradiation per square meter received by the modules
of the given system [kWh/m²].
SD_m: Standard deviation of the monthly electricity production due to year-to-year variation [kWh].

The European Commission maintains this website to enhance public access to information about its initiatives and European
Union policies in general. Our goal is to keep this information timely and accurate. If errors are brought to our attention, we will PVGIS ©European Union, 2001-2021.
try to correct them.
Reproduction is authorised, provided the source is acknowledged,
However, the Commission accepts no responsibility or liability whatsoever with regard to the information on this site.
save where otherwise stated.
This information is:

i) of a general nature only and is not intended to address the specific circumstances of any particular individual or entity,
Report generated on 2021/10/16
ii) not necessarily comprehensive, complete, accurate or up to date,

iii) sometimes linked to external sites over which the Commission services have no control and for which the Commission
assumes no responsibility,

iv) not professional or legal advice (if you need specific advice, you should always consult a suitably qualified professional).

You might also like