ekor.rpa series 020


Self-powered protection unit

Reliable innovation. Personal solutions.


www.ormazabal.com
ekorsys units:
ekor.rpa series 020
automation, control, protection, metering and
Self-powered protection unit communications of the electrical network

Preface I
II

Increasingly complex medium voltage The ekor.rpa series 020 self-powered


7
distribution networks and with a protection units have been designed
1
greater presence of players in the to cover these needs, also meeting
6
system: photovoltaic plants, energy the requirements of the national
storage plants, electric vehicle charging and international standards and
facilities, etc. demand more developed recommendations. 2 4
protective equipment with more 8
Depending on the model, the
features.
ekor.rpa series 020 units can also
incorporate current directionality, as
well as metering functions. 3

Characteristics I. ekor.rpa series 020

Compact solution » Operation and maintenance 1 Display 3 Communications


ports
» LCD display
in cubicle » Fault reports 2 Menu keyboard 4 Status LEDs

» Integration in the control » Configuration software II. Switchgear


compartment - ekor.soft-xml software
- Configuration via keypad-Unit 6 Circuit 8 Current
» Reduced commissioning display breaker transformers
» Unit assembled, wired and tested in 7 Earthing switch
the factory
» Current transformers installed in the
Applications
bushings » Transformer protection
» Reliability » Feeder protection
» Optimisation of mean time between
failures (MTBF)
» External trip allowed in the event
of breakdown on electronic relay or
Vaux not available (FAIL-SAFE)
» Dual power: ANSI functions configuration
» Powered by protection current
ekor.rpa series 020 protection functions.
transformers
» Universal auxiliary power supply
» Availability
» Installation protected in the event
of absence or loss of auxiliary power
supply
» Uninterrupted service guaranteed

Design Metering
I Q

» Modular functionality V Angle (φ)


P
» Self-powered protection units
» Real-time metering
(I, V, P, Q, angle)

Check functionality and models on next page.


ekorsys units:
ekor.rpa series 020
automation, control, protection, metering and
communications of the electrical network Self-powered protection unit

Technical characteristics
ekor.rpa series 020 ekor.rpa-021 ekor.rpa-022
General characteristics
Dual power: Self-powered + 24/48/125 Vdc - 230 Vac  
Analogue current inputs 4(1) 4(1)
Analogue voltage inputs - 3(2)
Digital inputs/outputs 2/2 (3)
2/2(3)
Settings groups 1 1
Inverse time curve types: IEC and ANSI  
Protection functions
50-51[1]-51[2] 50N-51N[1]-51N[2] (5) (5)
50Ns-51Ns (5) (5)

46 46BC - (5)
67 67N - (5)
67Ns - (5)

49 - (5)
2nd harmonic tripping blocked (5) (5)
Cold load pickup - 
Automatic adjustment of functions 50/51 -50N/51N  
Metering
Current  
Voltage Active/reactive/apparent power - 
Phi angle (φ) - 
Settings and records
Watchdog (WD)  
Fault reports 10 10
Configurable LED/LED 4/0 4/0
Configuration via display / ekor.soft.xml  
Physical media 
Front port  1 x micro-USB  1 x micro-USB
Notes: Configuration:
(1)
Fourth Input exclusively for zero-sequence transformer. The value of IN will be calculated
(2)
Models with zero-sequence current transformer  Standard
(3)
The value of VN will be calculated Optional
(4)
Inputs for Fail Safe external trip
Outputs: Watchdog + general trip
(5)
Self-powered
ANSI functions
46 - Reverse sequence
46BC - Broken conductor detection
49 - Thermal overload
50 - Overcurrent instantaneous protection
50N - Earthing overcurrent instantaneous protection
50NS - Sensitive neutral overcurrent instantaneous protection
51 - Inverse time overcurrent protection
51N - Earthing overcurrent instantaneous protection
51NS - Inverse time sensitive neutral overcurrent protection
67 - Overcurrent directional protection
67N - Neutral overcurrent directional protection
67NS - Sensitive neutral overcurrent directional protection

www.ormazabal.com