Professional Documents
Culture Documents
Fanuc 21i Configuration Document
Fanuc 21i Configuration Document
FactoryWiz
Sending Options
2.11- Leader: %<10>
2.12- Trailer: %
2.23- Skip lines that contain: %
2.31- Automatic timeout: 7
Receiving Options
3.11- Program identifier 1: O
3.12- Program Identifier 2: :
3.21- Receive timeout: 3
3.31- Ignore data before first end-of-block: True
3.32- Ignore data after last end-of-block: True
Remote Commands
4.02- Request for file command: GET-
4.03- Request for file command (drip feed): DNC-
4:11- Request to save command: PUT-
Additional Notes:
Changing CNC Parameters:
1/3
8/1/2021 Fanuc 21i configuration document
Wiring Diagram:
Pinout includes RTS/CTS Handshaking
DB-9 com port Wire color DB-25 CNC Jumper?
(Disconnected) Shield 1
2 (Receive Data) Green 2 (Transmit Data)
3 (Transmit Data) Red 3 (Receive Data)
5 (Signal Ground) Black 7 (Signal Ground)
7 (RTS) Brown 5 (CTS)
2/3
8/1/2021 Fanuc 21i configuration document
8 (CTS) Blue 4 (RTS)
6 (DSR) JUMPER
8 (DCD)
20 (DTR)
Refresh Your Memory, Inc. | 6920 Santa Teresa Blvd Suite 201 | San Jose, CA 95119
408.224.9167 | www.factorywiz.com
https://desk.zoho.com/portal/factorywiz/en/kb/articles/fanuc-21i-configuration-document
3/3