Download as pdf or txt
Download as pdf or txt
You are on page 1of 52

MANUFACTURING

INFORMATION

I. Imported high quality the first grade oxygen free copper.

II. Insulation layer from Basell and Dupont.

III. Imported high quality 72A high carbon steel, Huaneng heat treatment galvanized drawing production line, we
guarantee no splicing.

IV. We test the cable breaking strength use "ends FIX" method.

V. Conductors adopts new semi conductive shielding materials for coating processing, cable anti-interference
performance is stronger.

VI. Cable torque will be eliminated by our patent equipment, users can use cable ditectly in well without being towed
on road.

VII. Each sampling have to pass tension test, torsion, bending, wear-resisting.

VIII. Each reel of cable have passed comprehensive performance test, tensile force, stable heat through pre-
stretching equipment imported from Germany, simulating well etc.

IX. IOS 9001 plant certified, API 9A certified, Germany TüV certified.

X. Huaneng products have been successfully used in more than 20 overseas countries through cooperation with
CNLC, CNPC, CNOOC, and SINOPEC.

Jiangsu Huaneng Cable Co., LTD.


INDEX
MANUFACTURING INFORMATION 1 W3F46P-HS-9.58 27

CABLE SPECIFICATION 3 WGSF46-11.8 28

HOW TO READ A PRODUCT CODE 4 W3BP-11.8 29

W7BPP-11.8 30

Product Index W7BPP-JY-11.8 /22.0 31

WGSB-3.5 5 W7F46PP-11.8 32

W4B(4H-185A)-4.70 6 FL-W7F46PP-11.8 33

WGSB-5.6 7 W7PFAPP-11.8 34

WGSF46-5.6 8 W7BPP-12.04 35

FL-WGSF46-5.6 9 W7F46PP-12.04 36

WGSF46-HS-5.6 10 W7PFAPP-12.04 37

WGSPFA-5.6 11 FL-W7F46PP-12.04 38

WGSNPFAF40-S75-5.60 12 W7BPP-12.4 39

W3BP-5.6 13 W7F46PP-HS-12.4 40

W4B-5.6 14 W7F46PP-12.4 41

W7B(7H-250A)-6.4 15 W7PFAPP-12.4 42

WGSB-8.0 16 W7BPP-13.2 43

WGSB-HS-8.0 17 W7F46PP-13.2 44

WGSF46-8.0 18 W7PFAPP-13.2 45

FL-WGSF46-8.0 19 W7F46PP-HS-13.2 46

WGSF46-HS-8.0 20 W7F46F40P-EHS-12.40 47

WGSPFA-8.0 21

W3BP-8.0 22

W3F46P-8.0 23 ABOUT HUANENG 48

W4BP-8.0 24 WARRANTY 49

W4F46P-8.0 25 CRETIFICATE OF ASSESSMENT 50

W7BFP-8.9 26

Jiangsu Huaneng Cable Co., LTD.


CABLE SPECIFICATION SUMMARY TABLE
SIZE (In) Max. Max. Breaking Breaking Weight in Stretch Nom. Voltage
Nom.Dia. Nom.Cap. No.Armor Wires (mm) & Wire Break Strength (N)
CABLE TYPE Nom. Dia. temp. temp. Strength Strength Air coeff. Resis. Rating
(mm) (pf/m) (in / out)
(In) (°C) (°F) (kN) (lbs) (kg/km) (ft/kft/klbs) (Ω/km) (VDC)

WGSB-3.5 1/8 3.50 150 300 8 1800 45 6.5 75.0 140 300

W4B(4H-185A)-4.7 3/16 4.70 150 300 13 2900 85 4.25 84.3 190 200

WGSB-5.6 7/32 5.60 150 300 25 5600 142 2.2 18.0 190 1200

WGSF46-5.6 7/32 5.60 232 450 25 5600 145 2.2 18.0 190 1200

FL-WGSF46-5.6 7/32 5.60 232 450 20 4500 148 2.2 18.0 190 1200

WGSF46-HS-5.6 7/32 5.60 232 450 30 6740 145 2.2 13.1 220 1200

WGSPFA-5.6 7/32 5.60 260 500 25 5600 148 2.2 18.0 190 1200

W3BP-5.6 7/32 5.60 150 300 25 5600 135 2.2 84.3 170 1000

W4B-5.6 7/32 5.60 150 300 25 5600 142 2.2 84.3 190 200

W7B(7H-250A)-6.4 1/4 6.40 150 300 25 5400 160 2.65 84.3 140 300

WGSB-8.0 5/16 8.00 150 300 45 10000 270 1.2 9.2 190 1500

WGSB-HS-8.0 5/16 8.00 150 300 55 12300 270 1.2 9.2 190 1500

WGSF46-8.0 5/16 8.00 232 450 45 10000 281 1.2 9.2 190 1500

FL-WGSF46-8.0 5/16 8.00 232 450 40 9000 281 1.2 9.2 190 1500

WGSF46-HS-8.0 5/16 8.00 232 450 55 12300 281 1.2 9.2 190 1500

WGSPFA-8.0 5/16 8.00 260 500 45 10000 281 1.2 9.2 190 1500

W3BP-8.0 5/16 8.00 150 300 45 10000 255 1.2 33.0 175 1000

W3F46P-8.0 5/16 8.00 232 450 45 10000 265 1.2 33.0 175 1000

W4BP-8.0 5/16 8.00 150 300 45 10000 260 1.2 36.0 200 1000

W4F46P-8.0 5/16 8.00 232 450 45 10000 266 1.2 36.0 200 1000

W7BFP-8.9 0.350 8.9 150 300 50 11250 307 1.043 52.0 180 300

W3F46P-HS-9.58 0.377 9.58 232 450 74 16650 352 1.2 18.0 190 1200

WGSF46-11.8 0.464 11.8 232 450 85 19000 565 0.714 2.0 200 1500

W3BP-11.8 15/32 11.8 150 300 85 19000 500 0.714 18.0 140 1500

W7BPP-11.8 15/32 11.8 150 300 85 19000 500 0.714 33.0 130 1000

W7BPP-JY-11.8/22.0 0.464/ 11.8 150 300 95 140 1000


0.866 21375 1200 0.714 33.0

W7F46PP-11.8 15/32 11.8 232 450 85 19000 509 0.714 33.0 130 1000

FL-W7F46PP-11.8 15/32 11.8 232 450 85 19000 509 0.714 33.0 130 1200

W7PFAPP-11.8 15/32 11.8 260 500 85 19000 509 0.714 33.0 130 1000

W7BPP-12.04 0.474 12.04 150 300 90 20230 565 0.61 33.0 160 1200

W7F46PP-12.04 0.474 12.04 232 450 90 20230 578 0.61 33.0 160 1200

W7PFAPP-12.04 0.474 12.04 232 450 90 20230 578 0.61 33.0 160 1200

FL-W7F46PP-12.04 0.474 12.04 232 450 80 18000 578 0.61 33.0 160 1200

W7BPP-12.4 0.490 12.4 150 300 90 20230 530 0.714 33.0 130 1200

W7F46PP-HS-12.4 15/32 12.4 232 450 110 24750 580 0.714 33.0 130 1200

W7F46PP-12.4 0.490 12.4 232 450 90 20230 565 0.714 33.0 130 1200

W7PFAPP-12.4 0.490 12.4 260 500 90 20230 565 0.714 33.0 130 1200

W7BPP-13.2 17/32 13.2 150 300 110 24720 648 0.714 33.0 140 1200

W7F46PP-13.2 0.520 13.2 232 450 110 24720 704 0.714 33.0 130 1200

W7PFAPP-13.2 17/32 13.2 260 500 110 24720 662 0.714 33.0 130 1200

W7F46PP-HS-13.2 0.520 13.2 232 450 125 28340 704 0.714 33.0 130 1200
HOW TO READ
A PRODUCT CODE

FL-W7F46PP-11.8
1 2 3 4 5 6

1 FL - Stainless Steel Wires Armored / GX - Fiber Optic

2 Wireline Logging Cable

3 Number of Conductors
GS - Monoconductor
3 / 4 / 5 / 6 / 7 - Multiconductors

4 Type of Electrical Insulation


B - Camtene
F40 - Teflon-ETFE
F46 - Teflon-FEP
PFA - PFA

5 Mechanical Shielding
P - Semi-conducting whole shield
PP - Semi-conducting shield and Semi-conducting whole shield

6 Cable Diameter (mm)

Jiangsu Huaneng Cable Co., LTD.


WGSB-3.5
1/8" 3.5 mm
MONOCONDUCTOR

Copper Conductor Inner Armor Wires

PP Insulation Outer Armor Wires

CONSTRUCTION
Copper Construction 7 * 0.21 mm 7 * 0.0082"
Insulation (PP) 1.71 mm 0.0673"
Number and Size of Wires
Inner Armor 12 * 0.47 mm 12 * 0.0185"
Outer Armor 18 * 0.47 mm 18 * 0.0185"
Average Wire Breaking Strength
Inner Armor 324 N 72.8 lbs
Outer Armor 324 N 72.8 lbs

PHYSICAL
Cable Diameter 3.50 mm ± 0.10 mm 0.138" ± 0.0039"
Cable Weight in Air 45 kg/km 30 lbs/kft
Temp Rating 150 °C 300 °F

MECHANICAL
Cable Breaking Strength 8 kN 5600 lbs
Maximum Suggested Working Tension 4 kN 2800 lbs
Minimum Shave Diameter 190 mm 7.5"
Cable Stretch Coefficient 7.3 m/km/5kN 6.5 ft/kft/klbs

ELECTRICAL
Voltage Rating 300 VDC 300 VDC
Insulation Resistance 500 MΩ·km 1640 MΩ·kft
Resistance Typical 75 Ω/km 22.8 Ω/kft
Capacitance @ 1kHz 140 pf/m 43 pf/ft

Huaneng Cable 6
W4B(4H-185A)-4.70
3/16" 4.70 mm
MULTICONDUCTOR

Copper Conductor Protection Layer

PP Insulation Inner Armor Wires

Filler Outer Armor Wires

CONSTRUCTION
Copper Construction 6 * 0.20 + 1 * 0.21 mm 6 * 0.0078" + 1 * 0.0082"
Insulation (PP) 0.19 mm 0.00748"
Protection 3.00 mm 0.118"
Number and Size of Wires
Inner Armor 18 * 0.47 mm 18 * 0.0185"
Outer Armor 18 * 0.64 mm 18 * 0.0251"
Average Wire Breaking Strength
Inner Armor 324 N 72.8 lbs
Outer Armor 601 N 135 lbs

PHYSICAL
Cable Diameter 4.70 mm ± 0.10 mm 0.18" ± 0.0039"
Cable Weight in Air 85 kg/km 57.4 lbs/kft
Temp Rating 150 °C 300 °F

MECHANICAL
Cable Breaking Strength 13 kN 2900 lbs
Maximum Suggested Working Tension 6.5 kN 1450 lbs
Minimum Shave Diameter 260 mm 10.5"
Cable Stretch Coefficient 4.78 m/km/5kN 4.25 ft/kft/klbs

ELECTRICAL
Voltage Rating 200 VDC 200 VDC
Insulation Resistance 500 MΩ·km 1640 MΩ·kft
Resistance Typical 84.3 Ω/km 25.6 Ω/kft
Capacitance @ 1 kHz 190 pf/m 58 pf/ft

7 Huaneng Cable
WGSB-5.6

7/32" 5.6 mm
MONOCONDUCTOR

Copper Conductor Inner Armor Wires

PP Insulation Outer Armor Wires

CONSTRUCTION
Copper Construction 19 * 0.26 mm 19 * 0.0102"
Insulation (PP) 2.64 mm 0.1039"
Number and Size of Wires
Inner Armor 12 * 0.79 mm 12 * 0.0311"
Outer Armor 18 * 0.79 mm 18 * 0.0311"
Average Wire Breaking Strength
Inner Armor 916N 206 lbs
Outer Armor 916N 206 lbs

PHYSICAL
Cable Diameter 5.60 mm ± 0.10 mm 0.220" ± 0.0039"
Cable Weight in Air 142 kg/km 96 lbs/kft
Temp Rating 150 °C 300 °F

MECHANICAL
Cable Breaking Strength 25 kN 5600 lbs
Maximum Suggested Working Tension 12.5 kN 2800 lbs
Minimum Shave Diameter 320 mm 13"
Cable Stretch Coefficient 2.5 m/km/5kN 2.2 ft/kft/klbs

ELECTRICAL
Voltage Rating 1200 VDC 1200 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 18 Ω/km 5.5 Ω/kft
Capacitance @ 1kHz 190 pf/m 58 pf/ft

Huaneng Cable 8
WGSF46-5.6

7/32" 5.6 mm
MONOCONDUCTOR

Copper Conductor Inner Armor Wires

F46 Insulation Outer Armor Wires

F40 Protection Layer

CONSTRUCTION
Copper Construction 19 * 0.26 mm 19 * 0.0102"
Insulation (TEFLON) 2.00 mm 0.0787"
Protection (TEFZEL) 2.64 mm 0.1039"
Number and Size of Wires
Inner Armor 12 * 0.79 mm 12 * 0.0311"
Outer Armor 18 * 0.79 mm 18 * 0.0311"
Average Wire Breaking Strength
Inner Armor 916 N 206 lbs
Outer Armor 916 N 206 lbs

PHYSICAL
Cable Diameter 5.60 mm ± 0.10 mm 0.220" ± 0.0039"
Cable Weight in Air 145 kg/km 97 lbs/kft
Temp Rating 232 °C 450 °F

MECHANICAL
Cable Breaking Strength 25 kN 5600 lbs
Maximum Suggested Working Tension 12.5 kN 2800 lbs
Minimum Shave Diameter 320 mm 13"
Cable Stretch Coefficient 2.5 m/km/5kN 2.2 ft/kft/klbs

ELECTRICAL
Voltage Rating 1200 VDC 1200 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 18 Ω/km 5.5 Ω/kft
Capacitance @ 1kHz 190 pf/m 58 pf/ft

9 Huaneng Cable
FL-WGSF46-5.6
7/32" 5.6 mm
MONOCONDUCTOR

Copper Conductor Inner Armor Wires (Stainless Steel 316)

F46 Insulation Outer Armor Wires (Stainless Steel 316)

F40 Protection Layer

CONSTRUCTION
Copper Construction 19 * 0.26 mm 19 * 0.010"
Insulation (TEFLON) 2.00 mm 0.0787"
Protection (TEFZEL) 2.64 mm 0.1039"
Number and Size of Wires
Inner Armor 12 * 0.79 mm 12 * 0.0311"
Outer Armor 18 * 0.79 mm 18 * 0.0311"
Average Wire Breaking Strength
Inner Armor 867 N 195 lbs
Outer Armor 867 N 195 lbs

PHYSICAL
Cable Diameter 5.60 mm ± 0.10 mm 0.220" ± 0.0039"
Cable Weight in Air 148 kg/km 99 lbs/kft
Temp Rating 232 °C 450 °F

MECHANICAL
Cable Breaking Strength 20 kN 4500 lbs
Maximum Suggested Working Tension 10 kN 2250 lbs
Minimum Shave Diameter 320 mm 13"
Cable Stretch Coefficient 2.5 m/km/5kN 2.2 ft/kft/klbs

ELECTRICAL
Voltage Rating 1200 VDC 1200 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 18 Ω/km 5.5 Ω/kft
Capacitance @ 1kHz 190 pf/m 58 pf/ft

Huaneng Cable 10
WGSF46-HS-5.6

7/32" 5.6 mm
MONOCONDUCTOR

Copper Conductor Inner Armor Wires

F46 Insulation Outer Armor Wires

F40 Protection Layer

CONSTRUCTION
Copper Construction 19 * 0.30 mm 19 * 0.0118"
Insulation (TEFLON) 2.14 mm 0.0842"
Protection (TEFZEL) 2.76 mm 0.1086"
Number and Size of Wires
Inner Armor 15 * 0.61 mm 15 * 0.0240"
Outer Armor 15 * 0.89 mm 15 * 0.0350"
Average Wire Breaking Strength
Inner Armor 600 N 135 lbs
Outer Armor 1300 N 292 lbs

PHYSICAL
Cable Diameter 5.60 mm ± 0.10 mm 0.220" ± 0.0039"
Cable Weight in Air 145 kg/km 97 lbs/kft
Temp Rating 232 °C 450 °F

MECHANICAL
Cable Breaking Strength 30 kN 6740 lbs
Maximum Suggested Working Tension 15 kN 3370 lbs
Minimum Shave Diameter 320 mm 13"
Cable Stretch Coefficient 2.5 m/km/5kN 2.2 ft/kft/klbs

ELECTRICAL
Voltage Rating 1200 VDC 1200 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 13.1 Ω/km 4.0 Ω/kft
Capacitance @ 1kHz 220 pf/m 67 pf/ft

11 Huaneng Cable
WGSPFA-5.6
7/32" 5.6 mm
MONOCONDUCTOR

Copper Conductor Inner Armor Wires

PFA Insulation Outer Armor Wires

CONSTRUCTION
Copper Construction 19 * 0.26 mm 19 * 0.010"
Insulation (PFA) 2.64 mm 0.1039"
Number and Size of Wires
Inner Armor 12 * 0.79 mm 12 * 0.0311"
Outer Armor 18 * 0.79 mm 18 * 0.0311"
Average Wire Breaking Strength
Inner Armor 916 N 206 lbs
Outer Armor 916 N 206 lbs

PHYSICAL
Cable Diameter 5.60 mm ± 0.10 mm 0.220" ± 0.0039"
Cable Weight in Air 148 kg/km 99 lbs/kft
Temp Rating 260 °C 500 °F

MECHANICAL
Cable Breaking Strength 25 kN 5600 lbs
Maximum Suggested Working Tension 12.5 kN 2800 lbs
Minimum Shave Diameter 320 mm 13"
Cable Stretch Coefficient 2.5 m/km/5kN 2.2 ft/kft/klbs

ELECTRICAL
Voltage Rating 1200 VDC 1200 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 18 Ω/km 5.5 Ω/kft
Capacitance @ 1kHz 190 pf/m 58 pf/ft

Huaneng Cable 12
WGSNPFAF40-S75-5.60

7/32" 5.6 mm
MONOCONDUCTOR

Copper Conductor Inner Armor Wires

F46 Insulation Outer Armor Wires

F40 Protection Layer

CONSTRUCTION
Copper Construction 19 * 0.26 mm 19 * 0.010"
Insulation (PFA) 2.04 mm 0.0803"
Protection (F40) 2.64 mm 0.1039"
Number and Size of Wires
Inner Armor 12 * 0.79 mm 12 * 0.0311"
Outer Armor 18 * 0.79 mm 18 * 0.0311"
Average Wire Breaking Strength
Inner Armor 867 N 195 lbs
Outer Armor 867 N 195 lbs

PHYSICAL
Cable Diameter 5.60 mm ± 0.10 mm 0.220" ± 0.0039"
Cable Weight in Air 148 kg/km 99 lbs/kft
Temp Rating 260 °C 500 °F

MECHANICAL
Cable Breaking Strength 22 kN 4950 lbs
Maximum Suggested Working Tension 11 kN 2475 lbs
Minimum Shave Diameter 320 mm 13"
Cable Stretch Coefficient 3.5 m/km/5kN 3.1 ft/kft/klbs

ELECTRICAL
Voltage Rating 1200 VDC 1200 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 18 Ω/km 5.5 Ω/kft
Capacitance @ 1kHz 190 pf/m 58 pf/ft

13 Huaneng Cable
W3BP-5.6
7/32" 5.6 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Shield Layer

PP Insulation Inner Armor Wires

Semi-conducting Filler Outer Armor Wires

CONSTRUCTION
Copper Construction 7 * 0.21 mm 7 * 0.0082"
Insulation (PP) 1.14 mm 0.0448"
Number and Size of Wires
Inner Armor 12 * 0.79 mm 12 * 0.0311"
Outer Armor 18 * 0.79 mm 18 * 0.0311"
Average Wire Breaking Strength
Inner Armor 916 N 206 lbs
Outer Armor 916 N 206 lbs

PHYSICAL
Cable Diameter 5.60 mm ± 0.10 mm 0.220" ± 0.0039"
Cable Weight in Air 135 kg/km 91 lbs/kft
Temp Rating 150 °C 300 °F

MECHANICAL
Cable Breaking Strength 25 kN 5600 lbs
Maximum Suggested Working Tension 12.5 kN 2800 lbs
Minimum Shave Diameter 320 mm 13"
Cable Stretch Coefficient 2.5 m/km/5kN 2.2 ft/kft/klbs

ELECTRICAL
Voltage Rating 1000 VDC 1000 VDC
Insulation Resistance 500 MΩ·km 1640 MΩ·kft
Resistance Typical 84.3 Ω/km 25.6 Ω/kft
Capacitance @ 1 kHz 170 pf/m 52 pf/ft

14 Huaneng Cable
W4B-5.6
7/32" 5.60 mm
MULTICONDUCTOR

Copper Conductor Protection Layer

PP Insulation Inner Armor Wires

Filler Outer Armor Wires

CONSTRUCTION
Copper Construction 6 * 0.20 + 1 * 0.21 mm 6 * 0.0078" + 1 * 0.0082"
Insulation (PP) 0.19 mm 0.0732"
Protection 3.00 mm 0.118"
Number and Size of Wires
Inner Armor 12 * 0.79 mm 12 * 0.0311"
Outer Armor 18 * 0.79 mm 18 * 0.0311"
Average Wire Breaking Strength
Inner Armor 916 N 206 lbs
Outer Armor 916 N 206 lbs

PHYSICAL
Cable Diameter 5.60 mm ± 0.10 mm 0.220" ± 0.0039"
Cable Weight in Air 142 kg/km 96 lbs/kft
Temp Rating 150 °C 300 °F

MECHANICAL
Cable Breaking Strength 25 kN 5600 lbs
Maximum Suggested Working Tension 12.5 kN 2800 lbs
Minimum Shave Diameter 320 mm 13"
Cable Stretch Coefficient 2.5 m/km/5kN 2.2 ft/kft/klbs

ELECTRICAL
Voltage Rating 200 VDC 200 VDC
Insulation Resistance 500 MΩ·km 1640 MΩ·kft
Resistance Typical 84.3 Ω/km 25.6 Ω/kft
Capacitance @ 1 kHz 190 pf/m 58 pf/ft

Huaneng Cable 15
W7B(7H-250A)-6.4

1/4" 6.4 mm
MULTICONDUCTOR

Copper Conductor Protection Layer

PP Insulation Inner Armor Wires

Filler Outer Armor Wires

CONSTRUCTION
Copper Construction 7 * 0.21 mm 7 * 0.0083"
Insulation (PP) 0.24 mm 0.0094"
Number and Size of Wires
Inner Armor 18 * 0.63 mm 18 * 0.0248"
Outer Armor 18 * 0.89 mm 18 * 0.0350"
Average Wire Breaking Strength
Inner Armor 582 N 131 lbs
Outer Armor 1162 N 261 lbs

PHYSICAL
Cable Diameter 6.40 mm ± 0.10 mm 0.252" ± 0.0039"
Cable Weight in Air 160 kg/km 107 lbs/kft
Temp Rating 150 °C 300 °F

MECHANICAL
Cable Breaking Strength 25 kN 5400 lbs
Maximum Suggested Working Tension 12.5 kN 2800 lbs
Minimum Shave Diameter 356 mm 14"
Cable Stretch Coefficient 2.8 m/km/5kN 2.65 ft/kft/klbs

ELECTRICAL
Voltage Rating 300 VDC 300 VDC
Insulation Resistance 500 MΩ·km 1640 MΩ·kft
Resistance Typical 84.3 Ω/km 25.6 Ω/kft
Capacitance @ 1 kHz 140 pf/m 43 pf/kft

16 Huaneng Cable
WGSB-8.0

5/16" 8.0 mm
MONOCONDUCTOR

Copper Conductor Inner Armor Wires

PP Insulation Outer Armor Wires

CONSTRUCTION
Copper Construction 19 * 0.37 mm 19 * 0.0146"
Insulation (PP) 3.81 mm 0.1496"
Number and Size of Wires
Inner Armor 12 * 1.11 mm 12 * 0.0437"
Outer Armor 18 * 1.11 mm 18 * 0.0437"
Average Wire Breaking Strength
Inner Armor 1808 N 406 lbs
Outer Armor 1808 N 406 lbs

PHYSICAL
Cable Diameter 8.00 mm ± 0.10 mm 0.315" ± 0.0039"
Cable Weight in Air 270 kg/km 184 lbs/kft
Temp Rating 150 °C 300 °F

MECHANICAL
Cable Breaking Strength 45 kN 10000 lbs
Maximum Suggested Working Tension 22.5 kN 5000 lbs
Minimum Shave Diameter 450 mm 18"
Cable Stretch Coefficient 1.35 m/km/5kN 1.2 ft/kft/klbs

ELECTRICAL
Voltage Rating 1500 VDC 1500 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 9.2 Ω/km 2.8 Ω/kft
Capacitance @ 1kHz 190 pf/m 58 pf/ft

Huaneng Cable 17
WGSB-HS-8.0

5/16" 8.0 mm
MONOCONDUCTOR

Copper Conductor Inner Armor Wires

PP Insulation Outer Armor Wires

CONSTRUCTION
Copper Construction 19 * 0.37 mm 19 * 0.0146"
Insulation (PP) 3.81 mm 0.1496"
Number and Size of Wires
Inner Armor 12 * 1.11 mm 12 * 0.0437"
Outer Armor 18 * 1.11 mm 18 * 0.0437"
Average Wire Breaking Strength
Inner Armor 1970 N 442 lbs
Outer Armor 1970 N 442 lbs

PHYSICAL
Cable Diameter 8.00 mm ± 0.10 mm 0.315" ± 0.0039"
Cable Weight in Air 270 kg/km 184 lbs/kft
Temp Rating 150 °C 300 °F

MECHANICAL
Cable Breaking Strength 55 kN 12300 lbs
Maximum Suggested Working Tension 27.5 kN 6150 lbs
Minimum Shave Diameter 450 mm 18"
Cable Stretch Coefficient 1.35 m/km/5kN 1.2 ft/kft/klbs

ELECTRICAL
Voltage Rating 1500 VDC 1500 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 9.2 Ω/km 2.8 Ω/kft
Capacitance @ 1kHz 190 pf/m 58 pf/ft

18 Huaneng Cable
WGSF46-8.0

5/16" 8.0 mm
MONOCONDUCTOR

Copper Conductor Inner Armor Wires

F46 Insulation Outer Armor Wires

F40 Protection Layer

CONSTRUCTION
Copper Construction 19 * 0.37 mm 19 * 0.0146"
Insulation (TEFLON) 2.85 mm 0.1122"
Protection (TEFZEL) 3.81 mm 0.1496"
Number and Size of Wires
Inner Armor 12 * 1.11 mm 12 * 0.0437"
Outer Armor 18 * 1.11 mm 18 * 0.0437"
Average Wire Breaking Strength
Inner Armor 1808 N 406 lbs
Outer Armor 1808 N 406 lbs

PHYSICAL
Cable Diameter 8.00 mm ± 0.10 mm 0.315" ± 0.0039"
Cable Weight in Air 281 kg/km 189 lbs/kft
Temp Rating 232 °C 450 °F

MECHANICAL
Cable Breaking Strength 45 kN 10000 lbs
Maximum Suggested Working Tension 22.5 kN 5000 lbs
Minimum Shave Diameter 450 mm 18"
Cable Stretch Coefficient 1.35 m/km/5kN 1.2 ft/kft/klbs

ELECTRICAL
Voltage Rating 1500 VDC 1500 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 9.2 Ω/km 2.8 Ω/kft
Capacitance @ 1kHz 190 pf/m 58 pf/ft

Huaneng Cable 19
FL-WGSF46-8.0
5/16" 8.0 mm
MONOCONDUCTOR

Copper Conductor Inner Armor Wires (Stainless Steel 316)

F46 Insulation Outer Armor Wires (Stainless Steel 316)

F40 Protection Layer

CONSTRUCTION
Copper Construction 19 * 0.37 mm 19 * 0.0146"
Insulation (TEFLON) 2.85 mm 0.1122"
Protection (ETFE) 3.81 mm 0.1496"
Number and Size of Wires
Inner Armor 12 * 1.11 mm 12 * 0.0437"
Outer Armor 18 * 1.11 mm 18 * 0.0437"
Average Wire Breaking Strength
Inner Armor 1600 N 360 lbs
Outer Armor 1600 N 360 lbs

PHYSICAL
Cable Diameter 8.00 mm ± 0.10 mm 0.315" ± 0.0039"
Cable Weight in Air 281 kg/km 189 lbs/kft
Temp Rating 232 °C 450 °F

MECHANICAL
Cable Breaking Strength 40 kN 9000 lbs
Maximum Suggested Working Tension 20 kN 4500 lbs
Minimum Shave Diameter 450 mm 18"
Cable Stretch Coefficient 1.35 m/km/5kN 1.2 ft/kft/klbs

ELECTRICAL
Voltage Rating 1500 VDC 1500 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 9.2 Ω/km 2.8 Ω/kft
Capacitance @ 1kHz 190 pf/m 58 pf/ft

20 Huaneng Cable
WGSF46-HS-8.0

5/16" 8.0 mm
MONOCONDUCTOR

Copper Conductor Inner Armor Wires

F46 Insulation Outer Armor Wires

F40 Protection Layer

CONSTRUCTION
Copper Construction 19 * 0.37 mm 19 * 0.0146"
Insulation (TEFLON) 2.85 mm 0.1122"
Protection (TEFZEL) 3.81 mm 0.1496"
Number and Size of Wires
Inner Armor 12 * 1.11 mm 12 * 0.0437"
Outer Armor 18 * 1.11 mm 18 * 0.0437"
Average Wire Breaking Strength
Inner Armor 1970 N 442 lbs
Outer Armor 1970 N 442 lbs

PHYSICAL
Cable Diameter 8.00 mm ± 0.10 mm 0.315" ± 0.0039"
Cable Weight in Air 281 kg/km 189 lbs/kft
Temp Rating 232 °C 450 °F

MECHANICAL
Cable Breaking Strength 55 kN 12300 lbs
Maximum Suggested Working Tension 27.5 kN 6150 lbs
Minimum Shave Diameter 450 mm 18"
Cable Stretch Coefficient 1.35 m/km/5kN 1.2 ft/kft/klbs

ELECTRICAL
Voltage Rating 1500 VDC 1500 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 9.2 Ω/km 2.8 Ω/kft
Capacitance @ 1kHz 190 pf/m 58 pf/ft

Huaneng Cable 21
WGSPFA-8.0

5/16" 8.0 mm
MONOCONDUCTOR

Copper Conductor Inner Armor Wires

PFA Insulation Outer Armor Wires

CONSTRUCTION
Copper Construction 19 * 0.37 mm 19 * 0.0146"
Insulation (PFA) 3.81 mm 0.1496"
Number and Size of Wires
Inner Armor 12 * 1.11 mm 12 * 0.0437"
Outer Armor 18 * 1.11 mm 18 * 0.0437"
Average Wire Breaking Strength
Inner Armor 1808 N 406 lbs
Outer Armor 1808 N 406 lbs

PHYSICAL
Cable Diameter 8.00 mm ± 0.10 mm 0.315" ± 0.0039"
Cable Weight in Air 281 kg/km 189 lbs/kft
Temp Rating 260 °C 500 °F

MECHANICAL
Cable Breaking Strength 45 kN 10000 lbs
Maximum Suggested Working Tension 22.5 kN 5000 lbs
Minimum Shave Diameter 450 mm 18"
Cable Stretch Coefficient 1.35 m/km/5kN 1.2 ft/kft/klbs

ELECTRICAL
Voltage Rating 1500 VDC 1500 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 9.2 Ω/km 2.8 Ω/kft
Capacitance @ 1kHz 190 pf/m 58 pf/ft

22 Huaneng Cable
W3BP-8.0

5/16" 8.0 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Shield Layer

PP Insulation Inner Armor Wires

Semi-conducting Filler Outer Armor Wires

CONSTRUCTION
Copper Construction 7 * 0.32 mm 7 * 0.0129"
Insulation (PP) 1.86 mm 0.0732"
Number and Size of Wires
Inner Armor 18 * 0.81 mm 18 * 0.0319"
Outer Armor 18 * 1.11 mm 18 * 0.0437"
Average Wire Breaking Strength
Inner Armor 963 N 216 lbs
Outer Armor 1808 N 406 lbs

PHYSICAL
Cable Diameter 8.00 mm ± 0.10 mm 0.315" ± 0.0039"
Cable Weight in Air 255 kg/km 171 lbs/kft
Temp Rating 150 °C 300 °F

MECHANICAL
Cable Breaking Strength 45 kN 10000 lbs
Maximum Suggested Working Tension 22.5 kN 5000 lbs
Minimum Shave Diameter 450 mm 18"
Cable Stretch Coefficient 1.35 m/km/5kN 1.2 ft/kft/klbs

ELECTRICAL
Voltage Rating 1000 VDC 1000 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 33 Ω/km 10 Ω/kft
Capacitance @ 1 kHz 175 pf/m 53 pf/ft

Huaneng Cable 23
W3F46P-8.0

5/16" 8.0 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Whole Shield Layer

F46 Insulation Inner Armor Wires

Semi-conducting Filler Outer Armor Wires

CONSTRUCTION
Copper Construction 7 * 0.32 mm 7 * 0.0129"
Insulation (TEFLON) 1.86 mm 0.0732"
Number and Size of Wires
Inner Armor 18 * 0.81 mm 18 * 0.0319"
Outer Armor 18 * 1.11 mm 18 * 0.0437"
Average Wire Breaking Strength
Inner Armor 963 N 216 lbs
Outer Armor 916 N 406 lbs

PHYSICAL
Cable Diameter 8.00 mm ± 0.10 mm 0.315" ± 0.0039"
Cable Weight in Air 265 kg/km 175 lbs/kft
Temp Rating 232 °C 450 °F

MECHANICAL
Cable Breaking Strength 45 kN 10000 lbs
Maximum Suggested Working Tension 22.5 kN 5000 lbs
Minimum Shave Diameter 450 mm 18"
Cable Stretch Coefficient 1.35 m/km/5kN 1.2 ft/kft/klbs

ELECTRICAL
Voltage Rating 1000 VDC 1000 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 33 Ω/km 10 Ω/kft
Capacitance @ 1 kHz 175 pf/m 53 pf/ft

24 Huaneng Cable
W4BP-8.0

5/16" 8.0 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Shield Layer

PP Insulation Inner Armor Wires

Semi-conducting Filler Outer Armor Wires

CONSTRUCTION
Copper Construction 7 * 0.30 mm 7 * 0.0118"
Insulation (PP) 1.60 mm 0.0629"
Number and Size of Wires
Inner Armor 18 * 0.81 mm 18 * 0.0319"
Outer Armor 18 * 1.11 mm 18 * 0.0437"
Average Wire Breaking Strength
Inner Armor 963 N 216 lbs
Outer Armor 1808 N 406 lbs

PHYSICAL
Cable Diameter 8.00 mm ± 0.10 mm 0.315" ± 0.0039"
Cable Weight in Air 260 kg/km 174 lbs/kft
Temp Rating 150 °C 300 °F

MECHANICAL
Cable Breaking Strength 45 kN 10000 lbs
Maximum Suggested Working Tension 27.5 kN 5000 lbs
Minimum Shave Diameter 450 mm 18"
Cable Stretch Coefficient 1.35 m/km/5kN 1.2 ft/kft/klbs

ELECTRICAL
Voltage Rating 1000 VDC 1000 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 36 Ω/km 10.9 Ω/kft
Capacitance @ 1 kHz 200 pf/m 61 pf/ft

Huaneng Cable 25
W4F46P-8.0

5/16" 8.0 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Shield Layer

F46 Insulation Inner Armor Wires

Semi-conducting Filler Outer Armor Wires

CONSTRUCTION
Copper Construction 7 * 0.30 mm 7 * 0.0118"
Insulation (TEFLON) 1.60 mm 0.0629"
Number and Size of Wires
Inner Armor 18 * 0.81 mm 18 * 0.0319"
Outer Armor 18 * 1.11 mm 18 * 0.0437"
Average Wire Breaking Strength
Inner Armor 963 N 216 lbs
Outer Armor 1808 N 406 lbs

PHYSICAL
Cable Diameter 8.00 mm ± 0.10 mm 0.315" ± 0.0039"
Cable Weight in Air 266 kg/km 178 lbs/kft
Temp Rating 232 °C 450 °F

MECHANICAL
Cable Breaking Strength 45 kN 10000 lbs
Maximum Suggested Working Tension 27.5 kN 5000 lbs
Minimum Shave Diameter 450 mm 18"
Cable Stretch Coefficient 1.35 m/km/5kN 1.2 ft/kft/klbs

ELECTRICAL
Voltage Rating 1000 VDC 1000 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 36 Ω/km 10.9 Ω/kft
Capacitance @ 1 kHz 200 pf/m 61 pf/ft

26 Huaneng Cable
W7BFP-8.9

0.350" 8.9 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Whole Shield Layer

PP Insulation Inner Armor Wires

Semi-conducting Shield Layer Outer Armor Wires

Semi-conducting Filler

CONSTRUCTION
Copper Construction 7 * 0.26 mm 7 * 0.0102"
Insulation (PP) 1.65 mm 0.0976"
Number and Size of Wires
Inner Armor 17 * 0.99 mm 17 * 0.0389"
Outer Armor 23 * 1.26 mm 23 * 0.0496"
Average Wire Breaking Strength
Inner Armor 1438 N 323 lbs
Outer Armor 1438 N 323 lbs

PHYSICAL
Cable Diameter 8.90 mm ± 0.10 mm 0.350" ± 0.0039"
Cable Weight in Air 307 kg/km 206 lbs/kft
Temp Rating 150 °C 300 °F

MECHANICAL
Cable Breaking Strength 50 kN 11250 lbs
Maximum Suggested Working Tension 25 kN 5625 lbs
Minimum Shave Diameter 400 mm 15.7"
Cable Stretch Coefficient 1.2 m/km/5kN 1.043 ft/kft/klbs

ELECTRICAL
Voltage Rating 300 VDC 1000 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 52 Ω/km 15.8 Ω/kft
Capacitance @ 1 kHz 180 pf/m 54.8 pf/kft

Huaneng Cable 27
W3F46P-HS-9.58

0.377" 9.58mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Whole Shield Layer

F46 Insulation Inner Armor Wires

Semi-conducting Filler Outer Armor Wires

CONSTRUCTION
Copper Construction 19 * 0.26 mm 19 * 0.0102"
Insulation (TEFLON) 2.45 mm 0.096"
Number and Size of Wires
Inner Armor 16 * 1.08 mm 16 * 0.0425"
Outer Armor 20 * 1.19 mm 20 * 0.047"
Average Wire Breaking Strength
Inner Armor 1977 N 444 lbs
Outer Armor 2401 N 540 lbs

PHYSICAL
Cable Diameter 9.58 mm ± 0.10 mm 0.377" ± 0.0039"
Cable Weight in Air 352 kg/km 236 lbs/kft
Temp Rating 232 °C 450 °F

MECHANICAL
Cable Breaking Strength 74 kN 16650 lbs
Maximum Suggested Working Tension 37 kN 8325 lbs
Minimum Shave Diameter 460 mm 18"
Cable Stretch Coefficient 1.35 m/km/5kN 1.2 ft/kft/klbs

ELECTRICAL
Voltage Rating 1200 VDC 1200 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 18 Ω/km 5.5 Ω/kft
Resistance Armor 5.9 Ω/km 1.8 Ω/kft
Capacitance @ 1kHz 190 pf/m 58 pf/ft

28 Huaneng Cable
WGSF46-11.8

15/32" 11.8 mm
MONOCzONDUCTOR

Copper Conductor Inner Armor Wires

F46 Insulation Outer Armor Wires

F40 Protection Layer

CONSTRUCTION
Copper Construction 19 * 0.78 mm 19 * 0.0207"
Insulation (TEFLON) 6.70 mm 0.2638"
Protection (TEFZEL) 7.50 mm 0.2953"
Number and Size of Wires
Inner Armor 24 * 0.99 mm 24 * 0.0389"
Outer Armor 24 * 1.26 mm 24 * 0.0496"
Average Wire Breaking Strength
Inner Armor 1438 N 323 lbs
Outer Armor 2330 N 523 lbs

PHYSICAL
Cable Diameter 11.80 mm ± 0.10 mm 0.464" ± 0.0039"
Cable Weight in Air 565 kg/km 379 lbs/kft
Temp Rating 232 °C 450 °F

MECHANICAL
Cable Breaking Strength 85 kN 19000 lbs
Maximum Suggested Working Tension 42.5 kN 9500 lbs
Minimum Shave Diameter 504 mm 20"
Cable Stretch Coefficient 0.8 m/km/5kN 0.714 ft/kft/klbs

ELECTRICAL
Voltage Rating 1500 VDC 1500 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 2.0 Ω/km 0.61 Ω/kft
Capacitance @ 1kHz 200 pf/m 61 pf/ft

Huaneng Cable 29
W3BP-11.8

15/32" 11.8 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Whole Shield Layer

PP Insulation Inner Armor Wires

Semi-conducting Filler Outer Armor Wires

CONSTRUCTION
Copper Construction 7 * 0.33 mm 7 * 0.0102"
Insulation (PP) 3.31 mm 0.130"
Number and Size of Wires
Inner Armor 24 * 0.99 mm 24 * 0.0389"
Outer Armor 24 * 1.26 mm 24 * 0.0496"
Average Wire Breaking Strength
Inner Armor 1438 N 323 lbs
Outer Armor 2330 N 523 lbs

PHYSICAL
Cable Diameter 11.80 mm ± 0.10 mm 0.464" ± 0.0039"
Cable Weight in Air 500 kg/km 335 lbs/kft
Temp Rating 150 °C 300 °F

MECHANICAL
Cable Breaking Strength 85 kN 19000 lbs
Maximum Suggested Working Tension 42.5 kN 9500 lbs
Minimum Shave Diameter 504 mm 20"
Cable Stretch Coefficient 0.8 m/km/5kN 0.714 ft/kft/klbs

ELECTRICAL
Voltage Rating 1500 VDC 1500 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 18 Ω/km 5.5 Ω/kft
Capacitance @ 1 kHz 140 pf/m 43 pf/ft

30 Huaneng Cable
W7BPP-11.8
15/32" 11.8 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Whole Shield Layer

PP Insulation Inner Armor Wires

Semi-conducting Shield Layer Outer Armor Wires

Semi-conducting Filler

CONSTRUCTION
Copper Construction 7 * 0.33 mm 7 * 0.0129"
Insulation (PP) 2.48 mm 0.0976"
Shield 2.50 mm 0.0988"
Number and Size of Wires
Inner Armor 24 * 0.99 mm 24 * 0.0389"
Outer Armor 24 * 1.26 mm 24 * 0.0496"
Average Wire Breaking Strength
Inner Armor 1438 N 323 lbs
Outer Armor 2330 N 523 lbs

PHYSICAL
Cable Diameter 11.80 mm ± 0.10 mm 0.464" ± 0.0039"
Cable Weight in Air 500 kg/km 335 lbs/kft
Temp Rating 150 °C 300 °F

MECHANICAL
Cable Breaking Strength 85 kN 19000 lbs
Maximum Suggested Working Tension 42.5 kN 9500 lbs
Minimum Shave Diameter 504 mm 20"
Cable Stretch Coefficient 0.8 m/km/5kN 0.714 ft/kft/klbs

ELECTRICAL
Voltage Rating 1000 VDC 1000 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 33 Ω/km 10 Ω/kft
Capacitance @ 1 kHz 130 pf/m 40 pf/kft
Shield Equilibrium 30 mV 30 mV
Shield the Interference 100 mV 100 mV

Huaneng Cable 31
W7BPP-JY-11.8 /22.0

15/32" 11.8 mm
MULTICONDUCTOR

Copper Conductor Inner Armor Wires

PP Insulation Outer Armor Wires

Semi-conducting Shield Layer Inner Protection layer

Semi-conducting Filler Harden Steel Armor Wire

Semi-conducting Whole Shield Layer Outer Protection Layer

CONSTRUCTION
Copper Construction 7 * 0.33 mm 7 * 0.0129"
Insulation (PP) 2.48 mm 0.0976"
Shield 2.50 mm 0.0988"
Number and Size of Wires
Inner Armor 24 * 0.99 mm 24 * 0.0389"
Outer Armor 24 * 1.26 mm 24 * 0.0496"
Average Wire Breaking Strength
Inner Armor 1695 N 381 lbs
Outer Armor 2691 N 605 lbs

PHYSICAL
Cable Diameter 11.80 mm ± 0.10 mm 0.464" ± 0.0039"
Hard Cable Diameter 22.00 mm ± 0.20 mm 0.866" ± 0.0078"
Cable Weight in Air 1200 kg/km 806 lbs/kft
Temp Rating 150 °C 300 °F

MECHANICAL
Cable Breaking Strength 95 kN 21375 lbs
Hard Cable Breaking Strength 150 kN 33750 lbs
Maximum Suggested Working Tension 47.5 kN 10687.5 lbs
Minimum Shave Diameter 800 mm 31"
Cable Stretch Coefficient 0.8 m/km/5kN 0.714 ft/kft/klbs

ELECTRICAL
Voltage Rating 1000 VDC 1000 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 33 Ω/km 10 Ω/kft
Capacitance @ 1 kHz 140 pf/m 42 pf/kft

32 Huaneng Cable
W7F46PP-11.8

15/32" 11.8 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Whole Shield Layer

F46 Insulation Inner Armor Wires

Semi-conducting Shield Layer Outer Armor Wires

Semi-conducting Filler

CONSTRUCTION
Copper Construction 7 * 0.33 mm 7 * 0.0129"
Insulation (TEFLON) 2.48 mm 0.0976"
Shield 2.50 mm 0.0988"
Number and Size of Wires
Inner Armor 24 * 0.99 mm 24 * 0.0389"
Outer Armor 24 * 1.26 mm 24 * 0.0496"
Average Wire Breaking Strength
Inner Armor 1438 N 323 lbs
Outer Armor 2330 N 523 lbs

PHYSICAL
Cable Diameter 11.80 mm ± 0.10 mm 0.464" ± 0.0039"
Cable Weight in Air 509 kg/km 341 lbs/kft
Temp Rating 232 °C 450 °F

MECHANICAL
Cable Breaking Strength 85 kN 19000 lbs
Maximum Suggested Working Tension 42.5 kN 9500 lbs
Minimum Shave Diameter 504 mm 20"
Cable Stretch Coefficient 0.8 m/km/5kN 0.714 ft/kft/klbs

ELECTRICAL
Voltage Rating 1000 VDC 1000 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 33 Ω/km 10 Ω/kft
Capacitance @ 1 kHz 130 pf/m 40 pf/kft
Shield Equilibrium 30 mV 30 mV
Shield the Interference 100 mV 100 mV

Huaneng Cable 33
FL-W7F46PP-11.8

15/32" 11.8 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Whole Shield Layer

F46 Insulation Inner Armor Wires (Stainless Steel 316)

Semi-conducting Shield Layer Outer Armor Wires (Stainless Steel 316)

Semi-conducting Filler

CONSTRUCTION
Copper Construction 7 * 0.33 mm 7 * 0.0129"
Insulation (TEFLON) 2.48 mm 0.0976"
Shield 2.50 mm 0.0988"
Number and Size of Wires
Inner Armor 24 * 0.99 mm 24 * 0.0389"
Outer Armor 24 * 1.26 mm 24 * 0.0496"
Average Wire Breaking Strength
Inner Armor 1438 N 323 lbs
Outer Armor 2118 N 476 lbs

PHYSICAL
Cable Diameter 11.80 mm ± 0.10 mm 0.464" ± 0.0039"
Cable Weight in Air 509 kg/km 341 lbs/kft
Temp Rating 232 °C 450 °F

MECHANICAL
Cable Breaking Strength 80 kN 18000 lbs
Maximum Suggested Working Tension 40 kN 9000 lbs
Minimum Shave Diameter 504 mm 20"
Cable Stretch Coefficient 0.8 m/km/5kN 0.714 ft/kft/klbs

ELECTRICAL
Voltage Rating 1200 VDC 1200 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 33 Ω/km 10 Ω/kft
Capacitance @ 1 kHz 130 pf/m 40 pf/kft
Shield Equilibrium 30 mV 30 mV
Shield the Interference 100 mV 100 mV

34 Huaneng Cable
W7PFAPP-11.8
15/32" 11.8 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Whole Shield Layer

PFA Insulation Inner Armor Wires

Semi-conducting Shield Layer Outer Armor Wires

Semi-conducting Filler

CONSTRUCTION
Copper Construction 7 * 0.33 mm 7 * 0.0129"
Insulation (PFA) 2.48 mm 0.0976"
Shield 2.50 mm 0.0988"
Number and Size of Wires
Inner Armor 24 * 0.99 mm 24 * 0.0389"
Outer Armor 24 * 1.26 mm 24 * 0.0496"
Average Wire Breaking Strength
Inner Armor 1438 N 323 lbs
Outer Armor 2330 N 523 lbs

PHYSICAL
Cable Diameter 11.80 mm ± 0.10 mm 0.464" ± 0.0039"
Cable Weight in Air 509 kg/km 341 lbs/kft
Temp Rating 260 °C 500 °F

MECHANICAL
Cable Breaking Strength 85 kN 19000 lbs
Maximum Suggested Working Tension 42.5 kN 9500 lbs
Minimum Shave Diameter 504 mm 20"
Cable Stretch Coefficient 0.8 m/km/5kN 0.714 ft/kft/klbs

ELECTRICAL
Voltage Rating 1000 VDC 1000 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 33 Ω/km 10 Ω/kft
Capacitance @ 1 kHz 130 pf/m 40 pf/kft
Shield Equilibrium 30 mV 30 mV
Shield the Interference 100 mV 100 mV

Huaneng Cable 35
W7BPP-12.04

0.474" 12.04 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Whole Shield Layer

PP Insulation Inner Armor Wires

Semi-conducting Shield Layer Outer Armor Wires

Semi-conducting Filler

CONSTRUCTION
Copper Construction 7 * 0.33 mm 7 * 0.0129"
Insulation (PP) 2.14 mm 0.0843"
Shield 2.15 mm 0.0846"
Number and Size of Wires
Inner Armor 18 * 1.19 mm 18 * 0.0468"
Outer Armor 18 * 1.66 mm 18 * 0.0653"
Average Wire Breaking Strength
Inner Armor 2078 N 467 lbs
Outer Armor 4045 N 910 lbs

PHYSICAL
Cable Diameter 12.04 mm ± 0.10 mm 0.474" ± 0.0039"
Cable Weight in Air 565 kg/km 379 lbs/kft
Temp Rating 150 °C 300 °F

MECHANICAL
Cable Breaking Strength 90 kN 20230 lbs
Maximum Suggested Working Tension 45 kN 10115 lbs
Minimum Shave Diameter 670 mm 26.4"
Cable Stretch Coefficient 0.7 m/km/5kN 0.61 ft/kft/klbs

ELECTRICAL
Voltage Rating 1200 VDC 1200 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 33 Ω/km 10 Ω/kft
Capacitance @ 1 kHz 160 pf/m 48 pf/kft
Shield Equilibrium 30 mV 30 mV
Shield the Interference 100 mV 100 mV

36 Huaneng Cable
W7F46PP-12.04
0.474" 12.04 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Whole Shield Layer

F46 Insulation Inner Armor Wires

Semi-conducting Shield Layer Outer Armor Wires

Semi-conducting Filler

CONSTRUCTION
Copper Construction 7 * 0.33 mm 7 * 0.0129"
Insulation (TEFLON) 2.14 mm 0.0843"
Shield 2.15 mm 0.0846"
Number and Size of Wires
Inner Armor 18 * 1.19 mm 18 * 0.0468"
Outer Armor 18 * 1.66 mm 18 * 0.0653"
Average Wire Breaking Strength
Inner Armor 2078 N 467 lbs
Outer Armor 4045 N 910 lbs

PHYSICAL
Cable Diameter 12.04 mm ± 0.10 mm 0.474" ± 0.0039"
Cable Weight in Air 578 kg/km 388 lbs/kft
Temp Rating 232 °C 450 °F

MECHANICAL
Cable Breaking Strength 90 kN 20230 lbs
Maximum Suggested Working Tension 45 kN 10115 lbs
Minimum Shave Diameter 670 mm 26.4"
Cable Stretch Coefficient 0.7 m/km/5kN 0.61 ft/kft/klbs

ELECTRICAL
Voltage Rating 1000 VDC 1000 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 33 Ω/km 10 Ω/kft
Capacitance @ 1 kHz 160 pf/m 48 pf/kft
Shield Equilibrium 30 mV 30 mV
Shield the Interference 100 mV 100 mV

Huaneng Cable 37
W7PFAPP-12.04

0.474" 12.04 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Whole Shield Layer

PFA Insulation Inner Armor Wires

Semi-conducting Shield Layer Outer Armor Wires

Semi-conducting Filler

CONSTRUCTION
Copper Construction 7 * 0.33 mm 7 * 0.0129"
Insulation (PFA) 2.14 mm 0.0843"
Shield 2.15 mm 0.0846"
Number and Size of Wires
Inner Armor 18 * 1.19 mm 18 * 0.0468"
Outer Armor 18 * 1.66 mm 18 * 0.0653"
Average Wire Breaking Strength
Inner Armor 2078 N 467 lbs
Outer Armor 4045 N 910 lbs

PHYSICAL
Cable Diameter 12.04 mm ± 0.10 mm 0.474" ± 0.0039"
Cable Weight in Air 578 kg/km 388 lbs/kft
Temp Rating 232 °C 450 °F

MECHANICAL
Cable Breaking Strength 90 kN 20230 lbs
Maximum Suggested Working Tension 45 kN 10115 lbs
Minimum Shave Diameter 670 mm 26.4"
Cable Stretch Coefficient 0.7 m/km/5kN 0.61 ft/kft/klbs

ELECTRICAL
Voltage Rating 1200 VDC 1200 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 33 Ω/km 10 Ω/kft
Capacitance @ 1 kHz 160 pf/m 48 pf/kft
Shield Equilibrium 30 mV 30 mV
Shield the Interference 100 mV 100 mV

38 Huaneng Cable
FL-W7F46PP-12.04
0.474" 12.04 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Whole Shield Layer

F46 Insulation Inner Armor Wires (Stainless Steel 316)

Semi-conducting Shield Layer Outer Armor Wires (Stainless Steel 316)

Semi-conducting Filler

CONSTRUCTION
Copper Construction 7 * 0.33 mm 7 * 0.0129"
Insulation (TEFLON) 2.14 mm 0.0843"
Shield 2.15 mm 0.0846"
Number and Size of Wires
Inner Armor 18 * 1.19 mm 18 * 0.0468"
Outer Armor 18 * 1.66 mm 18 * 0.0653"
Average Wire Breaking Strength
Inner Armor 1967 N 442 lbs
Outer Armor 3396 N 763 lbs

PHYSICAL
Cable Diameter 12.04 mm ± 0.10 mm 0.474" ± 0.0039"
Cable Weight in Air 578 kg/km 388 lbs/kft
Temp Rating 232 °C 450 °F

MECHANICAL
Cable Breaking Strength 80 kN 18000 lbs
Maximum Suggested Working Tension 40 kN 9000 lbs
Minimum Shave Diameter 670 mm 26.4"
Cable Stretch Coefficient 0.7 m/km/5kN 0.61 ft/kft/klbs

ELECTRICAL
Voltage Rating 1200 VDC 1200 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 33 Ω/km 10 Ω/kft
Capacitance @ 1 kHz 160 pf/m 48 pf/kft
Shield Equilibrium 30 mV 30 mV
Shield the Interference 100 mV 100 mV

Huaneng Cable 39
W7BPP-12.4
0.490" 12.4 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Whole Shield Layer

PP Insulation Inner Armor Wires

Semi-conducting Shield Layer Outer Armor Wires

Semi-conducting Filler

CONSTRUCTION
Copper Construction 7 * 0.33 mm 7 * 0.0129"
Insulation (PP) 2.70 mm 0.1064"
Shield 2.72 mm 0.1071"
Number and Size of Wires
Inner Armor 26 * 0.99 mm 26 * 0.0389"
Outer Armor 25 * 1.26 mm 25 * 0.0496"
Average Wire Breaking Strength
Inner Armor 1438 N 323 lbs
Outer Armor 2330 N 523 lbs

PHYSICAL
Cable Diameter 12.40 mm ± 0.10 mm 0.490" ± 0.0039"
Cable Weight in Air 530 kg/km 355 lbs/kft
Temp Rating 150 °C 300 °F

MECHANICAL
Cable Breaking Strength 90 kN 20230 lbs
Maximum Suggested Working Tension 45 kN 10115 lbs
Minimum Shave Diameter 504 mm 20"
Cable Stretch Coefficient 0.8 m/km/5kN 0.714 ft/kft/klbs

ELECTRICAL
Voltage Rating 1200 VDC 1200 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 33 Ω/km 10 Ω/kft
Capacitance @ 1 kHz 130 pf/m 40 pf/kft
Shield Equilibrium 30 mV 30 mV
Shield the Interference 100 mV 100 mV

40 Huaneng Cable
W7F46PP-HS-12.4

0.490" 12.4 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Whole Shield Layer

F46 Insulation Inner Armor Wires

Semi-conducting Shield Layer Outer Armor Wires

Semi-conducting Filler

CONSTRUCTION
Copper Construction 7 * 0.33 mm 7 * 0.0129"
Insulation (TEFLON) 2.48 mm 0.0976"
Shield 2.50 mm 0.0988"
Number and Size of Wires
Inner Armor 22 * 1.11 mm 22 * 0.0389"
Outer Armor 22 * 1.44 mm 22 * 0.0496"
Average Wire Breaking Strength
Inner Armor 2090 N 470 lbs
Outer Armor 3516 N 783 lbs

PHYSICAL
Cable Diameter 12.40 mm ± 0.10 mm 0.490" ± 0.0039"
Cable Weight in Air 580 kg/km 390 lbs/kft
Temp Rating 232 °C 450 °F

MECHANICAL
Cable Breaking Strength 110 kN 24750 lbs
Maximum Suggested Working Tension 55 kN 12375 lbs
Minimum Shave Diameter 504 mm 20"
Cable Stretch Coefficient 0.8 m/km/5kN 0.714 ft/kft/klbs

ELECTRICAL
Voltage Rating 1200 VDC 1200 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 33 Ω/km 10 Ω/kft
Capacitance @ 1 kHz 130 pf/m 40 pf/kft
Shield Equilibrium 30 mV 30 mV
Shield the Interference 100 mV 100 mV

Huaneng Cable 41
W7F46PP-12.4
0.490" 12.4 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Whole Shield Layer

F46 Insulation Inner Armor Wires

Semi-conducting Shield Layer Outer Armor Wires

Semi-conducting Filler

CONSTRUCTION
Copper Construction 7 * 0.40 mm 7 * 0.0157"
Insulation (TEFLON) 2.70 mm 0.1064"
Shield 2.71 mm 0.1071"
Number and Size of Wires
Inner Armor 26 * 0.99 mm 26 * 0.0389"
Outer Armor 25 * 1.26 mm 25 * 0.0496"
Average Wire Breaking Strength
Inner Armor 1438 N 323 lbs
Outer Armor 2330 N 523 lbs

PHYSICAL
Cable Diameter 12.40 mm ± 0.10 mm 0.490" ± 0.0039"
Cable Weight in Air 565 kg/km 378 lbs/kft
Temp Rating 232 °C 450 °F

MECHANICAL
Cable Breaking Strength 90 kN 20230 lbs
Maximum Suggested Working Tension 45 kN 10115 lbs
Minimum Shave Diameter 504 mm 20"
Cable Stretch Coefficient 0.8 m/km/5kN 0.714 ft/kft/klbs

ELECTRICAL
Voltage Rating 1200 VDC 1200 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 22 Ω/km 6.7 Ω/kft
Capacitance @ 1 kHz 160 pf/m 48 pf/kft
Shield Equilibrium 30 mV 30 mV
Shield the Interference 100 mV 100 mV

42 Huaneng Cable
W7PFAPP-12.4

0.490" 12.4 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Whole Shield Layer

PFA Insulation Inner Armor Wires

Semi-conducting Shield Layer Outer Armor Wires

Semi-conducting Filler

CONSTRUCTION
Copper Construction 7 * 0.33 mm 7 * 0.0129"
Insulation (PFA) 2.70 mm 0.1064"
Shield 2.71 mm 0.1071"
Number and Size of Wires
Inner Armor 26 * 0.99 mm 26 * 0.0389"
Outer Armor 25 * 1.26 mm 25 * 0.0496"
Average Wire Breaking Strength
Inner Armor 1438 N 323 lbs
Outer Armor 2330 N 523 lbs

PHYSICAL
Cable Diameter 12.40 mm ± 0.10 mm 0.490" ± 0.0039"
Cable Weight in Air 565 kg/km 378 lbs/kft
Temp Rating 260 °C 500 °F

MECHANICAL
Cable Breaking Strength 90 kN 20230 lbs
Maximum Suggested Working Tension 45 kN 10115 lbs
Minimum Shave Diameter 504 mm 20"
Cable Stretch Coefficient 0.8 m/km/5kN 0.714 ft/kft/klbs

ELECTRICAL
Voltage Rating 1200 VDC 1200 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 33 Ω/km 10 Ω/kft
Capacitance @ 1 kHz 130 pf/m 40 pf/kft
Shield Equilibrium 30 mV 30 mV
Shield the Interference 100 mV 100 mV

Huaneng Cable 43
W7BPP-13.2
17/32" 13.2 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Whole Shield Layer

PP Insulation Inner Armor Wires

Semi-conducting Shield Layer Outer Armor Wires

Semi-conducting Filler

CONSTRUCTION
Copper Construction 7 * 0.33 mm 7 * 0.0129"
Insulation (PP) 2.38 mm 0.0976"
Shield 2.40 mm 0.0945"
Number and Size of Wires
Inner Armor 16 * 1.505 mm 16 * 0.05925"
Outer Armor 20 * 1.67 mm 20 * 0.06575"
Average Wire Breaking Strength
Inner Armor 3325 N 747 lbs
Outer Armor 4094 N 920 lbs

PHYSICAL
Cable Diameter 13.20 mm ± 0.10 mm 0.520" ± 0.0039"
Cable Weight in Air 648 kg/km 434 lbs/kft
Temp Rating 150 °C 300 °F

MECHANICAL
Cable Breaking Strength 110 kN 24720 lbs
Maximum Suggested Working Tension 55 kN 12360 lbs
Minimum Shave Diameter 590 mm 23.5"
Cable Stretch Coefficient 0.8 m/km/5kN 0.714 ft/kft/klbs

ELECTRICAL
Voltage Rating 1200 VDC 1200 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 33 Ω/km 10 Ω/kft
Capacitance @ 1 kHz 140 pf/m 43 pf/kft
Shield Equilibrium 30 mV 30 mV
Shield the Interference 100 mV 100 mV

44 Huaneng Cable
W7F46PP-13.2

17/32" 13.2 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Whole Shield Layer

F46 Insulation Inner Armor Wires

Semi-conducting Shield Layer Outer Armor Wires

Semi-conducting Filler

CONSTRUCTION
Copper Construction 7 * 0.33 mm 7 * 0.0129"
Insulation (TEFLON) 2.38 mm 0.0936"
Shield 2.40 mm 0.0945"
Number and Size of Wires
Inner Armor 16 * 0.99 mm 16 * 0.05925"
Outer Armor 20 * 1.26 mm 20 * 0.06575"
Average Wire Breaking Strength
Inner Armor 3325 N 747 lbs
Outer Armor 4094 N 920 lbs

PHYSICAL
Cable Diameter 13.40 mm ± 0.10 mm 0.520" ± 0.0039"
Cable Weight in Air 704 kg/km 473 lbs/kft
Temp Rating 232 °C 450 °F

MECHANICAL
Cable Breaking Strength 110 kN 24720 lbs
Maximum Suggested Working Tension 55 kN 12360 lbs
Minimum Shave Diameter 590 mm 23.5"
Cable Stretch Coefficient 0.8 m/km/5kN 0.714 ft/kft/klbs

ELECTRICAL
Voltage Rating 1200 VDC 1200 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 33 Ω/km 10 Ω/kft
Capacitance @ 1 kHz 130 pf/m 40 pf/kft
Shield Equilibrium 30 mV 30 mV
Shield the Interference 100 mV 100 mV

Huaneng Cable 45
W7PFAPP-13.2
17/32" 13.2 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Whole Shield Layer

PFA Insulation Inner Armor Wires

Semi-conducting Shield Layer Outer Armor Wires

Semi-conducting Filler

CONSTRUCTION
Copper Construction 7 * 0.33 mm 7 * 0.0129"
Insulation (PFA) 2.38 mm 0.0936"
Shield 2.40 mm 0.0945"
Number and Size of Wires
Inner Armor 16 * 1.505 mm 16 * 0.05925"
Outer Armor 20 * 1.67 mm 20 * 0.06575"
Average Wire Breaking Strength
Inner Armor 3325 N 747 lbs
Outer Armor 4094 N 920 lbs

PHYSICAL
Cable Diameter 13.20 mm ± 0.10 mm 0.520" ± 0.0039"
Cable Weight in Air 662 kg/km 473 lbs/kft
Temp Rating 260 °C 500 °F

MECHANICAL
Cable Breaking Strength 110 kN 24720 lbs
Maximum Suggested Working Tension 55 kN 12360 lbs
Minimum Shave Diameter 590 mm 23.5"
Cable Stretch Coefficient 0.8 m/km/5kN 0.714 ft/kft/klbs

ELECTRICAL
Voltage Rating 1200 VDC 1200 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 33 Ω/km 10 Ω/kft
Capacitance @ 1 kHz 130 pf/m 40 pf/kft
Shield Equilibrium 30 mV 30 mV
Shield the Interference 100 mV 100 mV

46 Huaneng Cable
W7F46PP-HS-13.2

17/32" 13.2 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Whole Shield Layer

F46 Insulation Inner Armor Wires

Semi-conducting Shield Layer Outer Armor Wires

Semi-conducting Filler

CONSTRUCTION
Copper Construction 7 * 0.33 mm 7 * 0.0129"
Insulation (TEFLON) 2.38 mm 0.0936"
Shield 2.40 mm 0.0945"
Number and Size of Wires
Inner Armor 16 * 1.505 mm 16 * 0.05925"
Outer Armor 20 * 1.67 mm 20 * 0.06575"
Average Wire Breaking Strength
Inner Armor 3840 N 863 lbs
Outer Armor 4730 N 1062 lbs

PHYSICAL
Cable Diameter 13.20 mm ± 0.10 mm 0.520" ± 0.0039"
Cable Weight in Air 704 kg/km 473 lbs/kft
Temp Rating 232 °C 450 °F

MECHANICAL
Cable Breaking Strength 125 kN 28340 lbs
Maximum Suggested Working Tension 62.5 kN 14170 lbs
Minimum Shave Diameter 590 mm 23.5"
Cable Stretch Coefficient 0.8 m/km/5kN 0.714 ft/kft/klbs

ELECTRICAL
Voltage Rating 1200 VDC 1200 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 33 Ω/km 10 Ω/kft
Capacitance @ 1 kHz 130 pf/m 40 pf/kft
Shield Equilibrium 30 mV 30 mV
Shield the Interference 100 mV 100 mV

Huaneng Cable 47
W7F46F40P-EHS-12.40

15/32" 12.4 mm
MULTICONDUCTOR

Copper Conductor Semi-conducting Whole Shield Layer

F46/F40 Insulation Inner Armor Wires

Semi-conducting Shield Layer Outer Armor Wires

Semi-conducting Filler

CONSTRUCTION
Copper Construction 7 * 0.32 mm 7 * 0.0126"
Insulation (F46/ F40) 2.48 mm 0.0976"
Shield 2.50 mm 0.0988"
Number and Size of Wires
Inner Armor 22 * 1.11 mm 22 * 0.0389"
Outer Armor 22 * 1.44 mm 22 * 0.0496"
Average Wire Breaking Strength
Inner Armor 2090 N 470 lbs
Outer Armor 3516 N 783 lbs

PHYSICAL
Cable Diameter 12.40 mm ± 0.10 mm 0.490" ± 0.0039"
Cable Weight in Air 580 kg/km 390 lbs/kft
Temp Rating 260 °C 500 °F

MECHANICAL
Cable Breaking Strength 110 kN 24750 lbs
Maximum Suggested Working Tension 55 kN 12375 lbs
Minimum Shave Diameter 504 mm 20"
Cable Stretch Coefficient 0.8 m/km/5kN 0.714 ft/kft/klbs

ELECTRICAL
Voltage Rating 1200 VDC 1200 VDC
Insulation Resistance 15000 MΩ·km 50000 MΩ·kft
Resistance Typical 33 Ω/km 10 Ω/kft
Capacitance @ 1 kHz 130 pf/m 40 pf/kft
Shield Equilibrium 30 mV 30 mV
Shield the Interference 100 mV 100 mV

48 Huaneng Cable
ABOUT HUANENG

Huaneng Cable is the largest Electromechanical wireline Plan in China, for the petroleum industry.
We are a company with a commitment to provide service and solutions for our customers.

Quality
All workers of Huaneng Cable are dedicated to provide the highest quality wireline in compliance
with the electromechanical industry and with ISO-9001.

Huaneng Cable‘s quality control standards is strict from raw materials, manufacture process to
finished goods.

Knowledge
Huaneng Cable has 90 technicians, 6PHD, PDH working station and Provincial Grade Enterprise
Engineering & Technology Center, we cooperate with Wu Han University.

Service
With distribution points, Huaneng Cable is providing fast and effective service to customers home
& abroad.

Technology
Huaneng Cable has total 34 patents.

More than 40 years of client feed back support Huaneng Cable's manufacturing processes on
electromechanical cables.

Huaneng Cable 49
WARRANTY

Huaneng Cable warrants that electromechanical cable purchased from an authorized distributor
will be free from defects in materials or workmanship. Huaneng Cable also ensure that
electromechanical cable will meet with breaking strengths and electrical specification listed in our
catalogue.

The Buyer has the obligation to indicate the environmental conditions under which the cable will be
used, so the distributor can supply the correspondent electromechanical cable, Failure to do so will
cancel this warranty.

This warranty is given by Huaneng Cable subject to the following conditions

1. Breaking strength or electrical specification apply only to new, unused electromechanical cable.

2. The electromechanical cables must be stored, handled, used and maintained, and properly
inspected frequently during the period of use.

3. The cable must be installed by a qualified person.