Medium Voltage Distribution

Catalogue│2014

CPX – CLX – CBX – CVX


Vacuum contactors up to 12 kV
Fixed and withdrawable range of contactors
Fixed and withdrawable
range of vacuum contactors
up to 12 kV
Contents

General 5

Vacuum contactor range 8

CPX series, up to 3.6 kV


14
fixed version

CLX series, up to 7.2 kV


22
fixed version

CBX series, up to 12 kV
29
fixed version

CVX series, up to 12 kV
36
fixed/withdrawable version

Order forms 48

1
Customer requirements

High Safety

Ease of installation

Robustness

2
Our solutions
Our proven range of vacuum contactors offers the best solution to suit MV feeders for
industrial projects. They have a fast switching rate and a long mechanical life.
The design and contact materials fulfil the general requirements for contactor applications
of motor starters, transformers or capacitor bank feeders (incl. back-to-back installations) in
various industrial sectors.

High safety
> Highly visible mechanical indicators
> No hazardous tripping
> Comprehensive interlocks
> Strict application of quality standards
> Compliance with the highest standards
> Certification by independent organizations

Ease of installation
> Usage for all application in medium voltage
> Compact dimensions
> Easy to integrate into any panel
> Easy to operate, well suited for retrofit
> Environmentally friendly with no gas or oil interrupting medium

Robustness
> Extremely resistant to harsh environments
> Solid construction
> High mechanical stability against vibrations, altitude and temperature
> Limited Maintenance
Our components add value
to your installations

4
Fixed and withdrawable
vacuum contactors up to 12 kV
General

Presentation 6

Applications 6

Quality & Environment 7

Standards & Certifications 7

Product range 9

5
Fixed and withdrawable
vacuum contactors up to 12 kV
General

Presentation
B BSC_0049.eps

Pioneers of Vacuum Interrupter technology


Environmental regulations and constraints are becoming increasingly
stringent. Vacuum technology is the perfect answer by investing in
electrical equipment with a minimal environmental impact.
More than 70 years ago, Schneider Electric started to explore
the feasibility of interruption by vacuum. Schneider Electric
was among the earliest trend setters when vacuum switching
technology became industrially viable in the 1950’s.

A complete range of high performance interrupters


Moving contact Moving end plate Schneider Electric’s vacuum interrupter product range is the result
PM100224.eps

Bearing
of this ongoing effort to be the pacesetter in the field.
Flexible bellows
It features:
Ceramic envelope bbUp to 12 kV, AC3/AC4 duty for motors, transformers, resistors
Bellows shield
Spatter shield and general switching
Contacts (open) bbLow chopping current up to 0.5 A
Contacts (closed)
bbHigh interrupting current up to 6 kA
Fixing contact Fixing end plate
bbUp to 12 kV, AC3/AC4 duty for capacitor switching
bbLow shopping current up to 2.3 A
bbHigh interrupting current up to 4.5 kA
PM100225.eps

The range includes dedicated and optimized interrupter models


Chopping for the different ratings and both for insulation in air and other
current insulating media.

Applications
Vacuum contactors are mainly used in MV switchboards for high
requirement applications such as motor starting applications, and
applications in the Industrial, Mine & Metal or Oil & Gas sectors.
Industries, Mine & Metal or Oil & Gas. They can be used in more
specific activities such as public lighting or power factor correction.

Industry Mine & Metal Oil & Gas Public lighting

6
Fixed and withdrawable
vacuum contactors up to 12 kV
General

Quality & Environment


Quality production management
Certified quality under The vacuum interrupter manufacturing units are certified ISO 9001
ISO 9001 and ISO 9002
employing a mature and robust Quality Management System
(QMS).
bbFully automated controlled line for surface treatment and silver
plating
bbHigh performance ultra-high vacuum furnaces with automated
loading equipment
bbSemi-automatic equipment for voltage and current conditioning
bbFully automated and computer controlled test line for routine
testing
bbAll vacuum interrupters undergo X-ray radioscopy of their inner
and outer parts

Protected environment
Schneider Electric is committed to a long-term environmental
approach. All necessary measures have been taken in connection
with our services, suppliers and subcontractors to ensure that the
materials used in the composition of the equipment do not contain
any substances prohibited by regulations and directives.
In order to help you protect the environment and relieve you of any
concerns in terms of stocking or dismantling, Schneider Electric
Services offers to take back your equipment at the end of its life.

Standards & Certifications


Compliance with standards
Our vacuum contactors have been designed to meet or exceed
the requirement of international standards and BV certificate:
bbIEC60470
bbMarine certification
The design and production are certified:
bbISO 9001:2000
Production sites are certified:
bbISO 14001 (Environmental standard)

Certification
The certificate of conformity provides guarantees that the vacuum
contactor:
bbhas been subject to type tests according to EN 45001
standard procedures in accredited laboratories by independent
organizations
bbis in conformity with recognized international standards
Our range of vacuum contactors is currently being certified by
external EN 45011 accredited organizations, members of the STL
(Short circuit Testing Liaison):
bbEN 45001: general requirements for the competence of testing
and calibration laboratories
bbEN 45011: general requirements for bodies of operating product
certification systems

7
Vacuum contactor
range

8
Fixed and withdrawable
vacuum contactors up to 12 kV
Vacuum contactor range

Our range of vacuum contactors, based on years of


development within the Schneider Electric Research &
Product range
Development department, and the use of latest CPX series
technologies and extensive experience enable us to > CPX/CPX-C: Most compact design for up to 3.6 kV applications
offer a leading range of vacuum-type contactors from
3.6 to 7.2 kV

CLX series
> CLX: For motor starters up to 7.2 kV, offering front access to
terminals with its slim line

CBX series
> CBX/CBX-C/CBXS-C: A cubic arrangement for up to 7.2 kV &
12 kV applications
bbThree-phase or single-phase
bbInductive load or capacitive load category
bbMechanical interlock between two contactors for motor reverse
commands

CVX series
> CVX-C-F: A fixed type of CBX for capacitive switching
applications equipped with fuse holders (DIN or BS standard) up
to 12 kV

> CVX-07/CVX-C-07: Withdrawable type of CBX equipped with


fuse holders (DIN or BS standard) up to 7.2 kV
Inductive load or capacitive load categories

> CVX-C-12: A withdrawable type of CBX for capacitive switching


applications equipped with fuse holders (DIN or BS standard) up to
12 kV

9
Fixed and withdrawable
vacuum contactors up to 12 kV
Vacuum contactor range

CPX CLX CBX CVX

PM103792.eps
PM103789.eps

PM103784.eps
PM103787.eps

Functions
Protection and control of network
Rated voltage
3.6 kV 7.2 kV 7.2 kV 12 kV 7.2 kV 12 kV

Мах. rated short-circuit current


4 kA 6 kA 6 kA 4 kA 6 kA* 4 kA
Мах. rated current
400 А (АС4) 400 А (АС4) 400 А (АС4) 315 А (АС4) 400 А (АС4) 315 A (АС4)
Versions
● Fixed ● Fixed ● Fixed ● Withdrawable СВХ • Withdrawable СВХ
versioп equipped with DIN versioп equipped with DIN or
or BS fuses BS fuses
● Optioпal оп board auxiliary
voltage traпsformer

Number of poles
3P 3P 1Р - ЗР 3P 3P
Mechanical switching cyc/es (ON/OFF)
250,000 (mechaпical latch) 250,000 (mechaпical latch) 250,000 (mechaпical latch) 250,000 (mechaпical latch) 250,000 (mechaпical latch)
апd 1,000,000 (magпetically апd 1,000,000 (magпetically апd 1,000,000 (magпetically апd 1,000,000 (magпetically апd 1,000,000 (magпetically
held) held) held) held) held)
Mechanism
Magnetic Magnetic Magnetic Magnetic Magnetic
or mechanical latch or mechanical latch or mechanical latch or mechanical latch or mechanical latch
IEC staпdards IEC staпdards IEC, GB (Chinese) standards IEC, GB staпdards IEC, GB staпdards

Benefits
Special withdrawable version Froпt access to terminals Special version available for ● High short circuit breaking ● High short circuit breaking
for capacitor banks capacitor bаnks capacity in combinatioп capacity in combinatioп
with fuses with fuses
● LV supply thaпks to optional
оn board VТ

Remark: * 50 kA in conjunction with fuses.

10
Fixed and withdrawable
vacuum contactors up to 12 kV
Vacuum contactor range

Maximum switching capacities


For the CPX/CLX/CBX ranges, when the contactors are not used in
conjunction with fuses, the maximum switching capacities are as follows:

Switching capacity CPX CPX-C CLX CBX CBX-C


Rated voltage kV 3.6 7.2 7.2 12
insulation load
kW 1900 1500 3900 3900 5300
Maximum motor rating
Capacitive load
kVAr / 1200 / / 3360 5600
Maximum capacitive bank rating
Short time withstand current
1s kA 6 5 6 6 4
30 s kA 2.4 1.9 2.4 2.4 1.9
Peak on 1/2 cycle IkAp 15 12.5 15 40 25

11
12
Fixed and withdrawable
vacuum contactors up to 12 kV
Vacuum contactor range

CPX/CPX-C series, up to 3.6 kV fixed version


Description of the device 14
Description of functions 16
Dimensions 18
Electric circuit diagram 19
Spare parts 21

CLX series, up to 7.2 kV fixed version


Description of the device 22
Description of functions 24
Dimensions 26
Electric circuit diagram 27
Spare parts 28

CBX/CBX-C/CBXS-C series, up to 12 kV fixed version


Description of the device 29
Description of functions 31
Dimensions 33
Electric circuit diagram 34
Spare parts 35

CVX series, up to 12 kV fixed version / withdrawable version


Description of the device 36
Description of functions 41
Dimensions 43
Electric circuit diagram 45
Fuse selection 46
Spare parts 47

Order forms
CPX/CPX-C, up to 3.6 kV fixed version 48
CLX, up to 7.2 kV fixed version 49
CBX/CBX-C/CBXS-C, up to 12kV fixed version 50
CVX series, up to 12 kV fixed version /withdrawable version 51

13
Vacuum contactor range CPX/CPX-C series, up to 3.6 kV
fixed version

Description of the device


PM103787.eps

The vacuum contactors CPX/CPX-C include:


For the electromagnetic mechanism and mechanical latch mechanism:
bbMain and armature moulding with two pivot points
bbA steel mounting plate
bbThree vacuum switches
bbTwo closing coils
bbOne or two auxiliary contact blocks
And for the mechanical latch mechanism:
bbOne mechanical latch
bbOne tripping coil

Front view
PM100226.eps

Phase assembly Stop pin & nut


Armature moulding

Pivot point
Main terminals (top)
Auxiliary block

Main terminals (buttom)


Mounting plate

Vacuum switch

Main moulding

Rear view
PM100227.eps

Closing coil Armature plate

Opening spring

Applications
CPX/CPX-C vacuum contactors are three phase switching devices, and
each phase has a separate vacuum switch which switches at the first
available current zero point.
bbCPX: Up to 3.6 kV, for motor starting/reversing applications
bbCPX-C: Up to 3.6 kV, for capacitor bank switching applications

14
Vacuum contactor range CPX/CPX-C series, up to 3.6 kV
fixed version

Main characteristics
CPX CPX-C
Electrical characteristics according to IEC 60470
Phase to phase distance mm 63.5 63.5
Rated voltage Ur kV 50/60 Hz 3.6 3.6
Insulation power frequency withstand Ud kV 50/60 Hz 1 min 10 10
level
lightning impulse withstand Up kV peak 40 40
Rated operational current Ith A 400 315
Rated thermal current Ie A 400 400
Rated short-circuit breaking current Isc kA 6 4.5
Rated short-time withstand current Ik/tk kA/1 s 6 5
Rated peak withstand current Ip kA 15 12.5

Common characteristics according to IEC 60470


Switch frequency op./h 300
Mechanical for electromagnetic mechanism op. 1,000,000
endurance
for mechanical latch mechanism op. 200,000
Electrical endurance at rated current op. 250,000
Consumption closing power W 180
Consumption holding power (magnet type) W 90
Closing time ms 40-80
Consumption opening power (mechanical type) W 240
Opening time for DC supply ms 40-70
for AC supply ms 50-80
Operating rated ambient temperature °C -5/40
Average relative humidity over 24 h <95%
over 1 month <90%

15
Vacuum contactor range CPX/CPX-C series, up to 3.6 kV
fixed version

Description of functions
Basic frame
PM100228.eps

For vacuum contactors CPX/CPX-C, the basic frame consist of:


(2)
bb(1) Main moulding
(5) bb(2) Armature moulding
(3)
bb(3) Two pivot points
bb(4) Steel mounting plate
(1)
bb(5) Stop pin and nut

(4)

Power part
PM100229.eps

(9)
For vacuum contactors CPX/CPX-C, 3 pieces of power parts are
assembled whereby each power part consists of:
bb(6) Vacuum switch
bb(7) Main terminals (top)
(7) bb(8) Main terminals (bottom)
(6) bb(9) Phase assembly
For the vacuum switch type,
(8)
bbVS2 is for CPX, inductive load category
bbVS2-C is for CPX-C, capacitive load category

Closing coil
PM100230.eps

For vacuum contactors CPX/CPX-C, 2 pieces of closing coils are


assembled, each closing coil has various options for supply voltage:
bbDC 24 V
bbDC 48 V
bbDC 60 V
bbDC 110 V
bbDC 125 V
bbDC 220 V
bbDC 250 V
bbAC 110 V
bbAC 120 V
bbAC 220 V
bbAC 240 V

16
Vacuum contactor range CPX/CPX-C series, up to 3.6 kV
fixed version

Auxiliary contact
PM100231.eps

For vacuum contactors CPX/CPX-C, various auxiliary contacts are


assembled and optional:

For the electromagnetic hold mechanism:


bb2NO + 1NC, left side assembly
bb4NO + 4NC, left & right side assembly
bb4NO + 4NC, left side & right facing assembly

For the mechanical latch mechanism:


bb2NO + 3NC, left side assembly
bb5NO + 5NC, left & right side assembly
bb5NO + 5NC, left side & right facing assembly

Mechanical latch with tripping coil


PM100232.eps

For vacuum contactors CPX/CPX-C, the mechanical latch mechanism


with a tripping coil can be selected instead of the electromagnetic hold
mechanism. It includes 1 mechanical latch and 1 tripping coil:
bbMechanical latch part

A corresponding tripping coil with various options for supply voltage:


bbDC 24-30 V
bbDC 48-60 V
bbDC 110-250 V
PM100233.eps

bbAC 110-240 V

17
Vacuum contactor range CPX/CPX-C series, up to 3.6 kV
fixed version

Dimensions

For CPX/CPX-C electromagnetic hold mechanical latch


Phase to phase distance mm 63.5 63.5
Size (W x D x H) mm 282 x 193 x 207 282 x 230 x 207
Weight kg 11 11

For electromagnetic hold mechanism

230
PM100241.eps

PM100238.eps

207
193
103

13

53.7 63.5 63.5


282

For mechanical latch mechanism

230
PM100239.eps

PM100238.eps

193
207
230 103

13

53.7 63.5 63.5


282

18
Vacuum contactor range CPX/CPX-C series, up to 3.6 kV
fixed version

Electric circuit diagram


For the CPX/CPX-C electromagnetic hold mechanism and DC supply
PM100234.eps voltage:

T (2 pts) AS 1 AS 2
+ 20 22 24 42 40 20 22 24 42 40

CC1 1 CC2 1

2 2

- 21 23 25 43 41 21 23 25 43 41

L1 L2 L3

Main circuit Control circuit Position Position


indication indication
(options)

For the CPX/CPX-C mechanical latch mechanism and DC supply voltage:


PM100235.eps

T (4 pts) AS 1 AS 2
1 3 21 23 25 43 41 21 23 45 43 41

CC1 CC2 TC
1 2 1

2 1 2

2 4 20 22 24 42 40 20 22 44 42 40

L1 L2 L3

Main circuit Control circuit Position Position


indication indication
(options)

19
Vacuum contactor range CPX/CPX-C series, up to 3.6 kV
fixed version

Electric circuit diagram


For the CPX/CPX-C electromagnetic hold mechanism and AC supply
voltage:
PM100236.eps

T (2 pts)
1
AS 1 AS 2
20 22 24 42 40 20 22 24 42 40

GB
- +
V

CC1 1 CC2 1

2 2

21 23 25 43 41 21 23 25 43 41

L1 L2 L3

Main circuit Control circuit Position Position


indication indication
(options)

For the CPX/CPX-C mechanical latch mechanism and AC supply voltage:


PM100237.eps

T (4 pts) AS 1 AS 2
1 3 21 23 25 43 41 21 23 25 43 41

GB
- + CC1
1
CC2
1 TC
V 1
2 2
2

2 4 20 22 24 42 40 20 22 24 42 40

L1 L2 L3

Main circuit Control circuit Position Position


indication indication
(options)

20
Vacuum contactor range Spare parts

Spare parts *
Auxiliary switch
3.6 kV 400 A Inductive load Magnetical hold 2NO + 1NC
PM100231-red.eps

315 A Capacitive load 4NO + 4NC


Mechanical latch 2NO + 3NC
5NO + 5NC

Coils
3.6 kV 400 A Inductive load DC 24 V
PM100230-red.eps

315 A Capacitive load 48 V


60 V
110 V
125 V
220 V
250 V
AC 110 V
120 V
220 V
240 V

Mechanical latch
3.6 kV 400 A Inductive load
PM100232-red.eps

315 A Capacitive load

Tripping coil
3.6 kV 400 A Inductive load DC 24-30 V
PM100233-red.eps

315 A Capacitive load 48-60 V


110-250 V
AC 110-240 V

*: The spare parts could be ordered through the logistics of the manufacturing plant.

21
Vacuum contactor range CLX series, up to 7.2 kV
fixed version

Description of the device


PM103789.eps

The vacuum contactors CLX include:


For the electromagnetic mechanism and the mechanical:
bbA main frame moulding with two pivot points
bbA steel L-shaped armature
bbSheet steel side mounting plates
bbThree vacuum switches
bbTwo closing coils
bbOne auxiliary contact block
bbOne electronic card and operations counter
And for the mechanical latch mechanism:
bbOne mechanical latch
bbOne tripping coil

Front view
Main terminals
PM100242.eps

For vacuum switch


Main moulding

Main terminals
Moulded terminals
bar Isolating rod

Flexible connection
Auxiliary switches
Electronic card

4 x M10 fixing holes

Rear view
4 x M10 fixing holes
PM100243.eps

Pivot point

L shaped armature

4 x M10 fixing holes

Applications
CLX vacuum contactors are three phase switching devices, and each
phase has a separate vacuum switch that switches at the first available
current zero point.
bbCLX: Up to 7.2 kV, for motor starting/reversing applications

22
Vacuum contactor range CLX series, up to 7.2 kV
fixed version

Main characteristics

x CLX
Electrical characteristics according to IEC 60470
Phase to phase distance mm 120
Rated voltage Ur kV 50/60 Hz 7.2
Insulation power frequency withstand Ud kV 50/60 Hz 1 min 20
level
lightning impulse withstand Up kV peak 60
Rated operational current Ith A 400
Rated thermal current Ie A 400
Rated short-circuit breaking current Isc kA 6
Rated short-time withstand current Ik/tk kA/1 s 6
Rated peak withstand current Ip kA 15

Common characteristics according to IEC 60470


Switch frequency op./h 300
Mechanical for electromagnetic mechanism op. 1,000,000
endurance
for mechanical latch mechanism op. 200,000
Electrical endurance at rated current op. 250,000
Consumption closing power W 500
Consumption holding power (magnet type) W 80
Closing time ms 120-200
Consumption opening power (mechanical type) W 240
Opening time for DC supply ms 50-100
for AC supply ms 50-100
Operating rated ambient temperature °C -5/40
Average relative humidity over 24 h <95%
over 1 month <90%

23
Vacuum contactor range
CLX series, up to 7.2 kV
fixed version

Description of functions
Basic frame
PM100244.eps

For the vacuum contactors CLX, the basic frame includes:


bb(1) Main moulding
bb(2) Sheet steel side mounting plates
bb(3) Two pivot points
bb(4) A steel L-shaped armature

(1)

(4)
(2)

(3)

Power part
(5)
PM103052.eps

For the vacuum contactors CLX, 3 pieces of power parts are assembled,
every power part includes:
bb(5) Main terminals (top)
bb(6) Main terminals (bottom)
bb(7) Vacuum switch
(6)

(7)
For the vacuum switch type,
bbVS3 is for CLX, inductive load category
PM103053.eps

Closing coil
For the vacuum contactors CLX, 2 pieces of closing coils are assembled,
every piece of closing coil has various options for supply voltage:
bbDC 24-60 V
bbDC 110-250 V/AC 110-240 V
PM103054.eps

Auxiliary contact
For the vacuum contactors CLX, various auxiliary contacts are assembled
and optional:
For electromagnetic hold mechanism:
bb5NO + 5NC, right hand side assembly, without opening delay
bb5NO + 5NC, right hand side assembly, with 100 ms opening delay

24
Vacuum contactor range CLX series, up to 7.2 kV
fixed version

Mechanical latch with tripping coil


PM103055.eps

For the vacuum contactors CLX, the mechanical latch mechanism


with the tripping coil can be selected instead of the electromagnetic
hold mechanism. It consists of a 1 piece mechanical latch and 1 piece
tripping coil:
bbA mechanical latch part

A corresponding tripping coil with various options for supply voltage:


PM100233.eps

bbDC 24-30 V
bbDC 48-60 V
bbDC 110-250 V/AC 110-240 V

Electronic card
PM103067.eps

For the vacuum contactors CLX, a set of electronic card is equipped, and
has various options for supply voltage:
bbDC 24-60 V
bbDC 110-250 V/AC 110-240 V

Operations counter
PM103057.eps

For the vacuum contactors CLX, an operations counter is equipped.

25
Vacuum contactor range
CLX series, up to 7.2 kV
fixed version

Dimensions

For CLX electromagnetic hold mechanical latch


Phase to phase distance mm 120 120
Size (W x D x H) mm 411.5 x 218 x 398.5 411.5 x 218 x 398.5
Weight kg 21 21

For the electromagnetic hold mechanism

218 120 120


PM103056.eps

PM103059.eps
142
210
398.5

231.5
155

47
334
411.5

For the mechanical latch mechanism

218 120 120


PM103058.eps

PM103060.eps

142
210
398.5

231.5
155

47
334
411.5

26
Vacuum contactor range CLX series, up to 7.2 kV
fixed version

Electric circuit diagram

<Sans lien d'intersection>


CLX electromagnetic hold mechanism and DC & AC supply voltage:

1
Carte Electronique
CC1
Electronic Card 2

2
CC2 1 1 1 1 1 1 1 1 1 1
- + 1

Alimentation
Vdc ou Vac
Vdc or Vac supply

S11 S21 S12 S22 S13 S23 S14 S24 S15 S25

2 4 2 42 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4
L1 L2 L3

Main Control circuit 5 NO + 5 NC


circuit

CLX mechanical latch mechanism and DC & AC supply voltage:


PM103069.eps

1
Carte Electronique
CC1
Electronic Card 2
1 TC
2
2 CC2 1 1 1 1 1 1 1 1 1 1
- + 1

Alimentation
Vdc ou Vac
Vdc or Vac supply

S11 S21 S12 S22 S13 S23 S14 S24 S15 S25

2 4 2 42 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4
L1 L2 L3

Main Control circuit 5 NO + 5 NC


circuit

27
Vacuum contactor range Spare parts

Spare parts *
Auxiliary switch
Right hand side switch
PM103054-red.eps

7.2 kV 400 A Inductive load 5NO + 5NC

Coils
7.2 kV 400 A Inductive load DC 24-60 V
PM103053-red.eps

110-250 V
AC 110-240 V

Mechanical latch
7.2 kV 400 A Inductive load
PM103055-red.eps

Tripping coil
7.2 kV 400 A Inductive load DC 24-30 V
PM100233-red.eps

48-60 V
110-250 V
AC 110-240 V

Electronic card
7.2 kV 400 A Inductive load DC 24-30 V
PM103067-red.eps

110-250 V
AC 110-240 V

Operations counter
7.2 kV 400 A Inductive load
PM103057-red.eps

*: The spare parts could be ordered through the logistics of the manufacturing plant.

28
Vacuum contactor range CBX/CBX-C/CBXS-C series,
up to 12 kV fixed version

Description of the device


PM103784.eps

The vacuum contactors CBX/CBX-C (1) include:


For electromagnetic mechanism and mechanical latch mechanism:
bbMain and armature moulding with two pivot points
bbA steel mounting plate
bbThree vacuum switches (one vacuum switch in CBXS-C)
bbTwo closing coils
bbOne auxiliary contact block
bbOne electronic card and operations counter
And for the mechanical latch mechanism:
bbOne mechanical latch
bbOne tripping coil

Front view
PM103061.eps

Armature moulding

Pivot point Auxiliary block

Operations counter
Closing coil
Electronic card Stop pin

Fixing holes Opening springs

Steel mounting plate

Rear view
PM103062.eps

Phase assembly

Main terminals (top) Moulded terminal


bar

Main moulding
Vacuum switches
Main terminals (bottom)

Applications
CBX/CBX-C vacuum contactors are three phase switching devices,
and each phase has a separate vacuum switch that switches at the first
available current zero point.
bbCBX: Up to 7.2 kV, for motor starting/reversing applications
bbCBX-C: Up to 12 kV, for capacitor bank switching applications.
(1) For the application of single phase contactor CBXS-C, please consult us for details.

29
Vacuum contactor range CBX/CBX-C/CBXS-C series,
up to 12 kV fixed version

Main characteristics

CBX CBX-C CBXS-C


Electrical characteristics according to IEC 60470
Phase to phase distance mm 108 108 /
Rated voltage Ur kV 50/60 Hz 7.2 12 12
Insulation level power frequency withstand Ud kV 50/60 Hz 1 min 20 28 28
lightning impulse withstand Up kV peak 60 75 75
Rated operational current Ith A 400 315 400
Rated thermal current Ie A 400 400 400
Rated short-circuit breaking current Isc kA 6 4 4
Rated short-time withstand current Ik/tk kA/1 s 6 4.8 5
Rated peak withstand current Ip kA 20 12.5 12.5

CBX CBX-C CBXS-C


Common characteristics according to IEC 60470
Switch frequency op./h 300 300
Mechanical endurance for electromagnetic mechanism op. 1,000,000 1,000,000
for mechanical latch mechanism op. 200,000 200,000
Electrical endurance at rated current op. 250,000 250,000
Consumption closing power W 500 80
Consumption holding power (magnet type) W 80 80
Closing time ms 120-200 70-110
Consumption opening power (mechanical type) W 240 240
Opening time for DC supply ms 50-100 25-50
for AC supply ms 50-100 25-50
Operating rated ambient temperature °C -5/40 -5/40

Average relative humidity over 24 h < 95% < 95%


over 1 month < 95% < 95%

30
Vacuum contactor range CBX/CBX-C/CBXS-C series,
up to 12 kV fixed version

Description of functions
PM103077.eps

Basic frame
For vacuum contactors CBX/CBX-C, the basic frame comprises by:
bb(1) Main moulding
bb(2) Armature moulding
bb(3) Two pivot points
(2)
bb(4) A steel mounting plate
bb(5) Stop pin
(1) (4)

(3) (5)

Power part
PM103078.eps

For vacuum contactors CBX/CBX-C, 3 pieces of power parts are assembled.


For CBXS-C, 1 piece of power part is assembled. Every piece of power
(7) part comprises by:
bb(6) Vacuum switch
bb(7) Main terminals (top)
bb(8) Main terminals (bottom)

For the vacuum switch type,


bbVS3 is for CBX, inductive load category
(6) bbVS3-C is for CBX-C/CBXS-C, capacitive load category

(8)

Closing coil
PM103053.eps

For vacuum contactors CBX/CBX-C, 2 pieces of closing coils are assembled,


every piece of closing coil has various options for supply voltage:
bbDC 24-60 V
bbDC 110-250 V/AC 110-240 V.

Auxiliary contact
PM103079.eps

For vacuum contactors CBX/CBX-C, various auxiliary contacts are


assembled and optional:
For electromagnetic hold mechanism:
bb5NO + 5NC, right hand side assembly, without opening delay
bb5NO + 5NC, right hand side assembly, with 100 ms opening delay

31
Vacuum contactor range CBX/CBX-C/CBXS-C series,
up to 12 kV fixed version

Mechanical latch with Tripping coil


PM103080.eps

For vacuum contactors CBX/CBX-C, the mechanical latch mechanism


with the tripping coil can be selected instead of the electromagnetic hold
mechanism. It is comprised by 1 piece mechanical latch and 1 piece tripping
coil:
bbA mechanical latch part

A corresponding tripping coil with various options for supply voltage:


bbDC 24-30 V
bbDC 48 V
bbDC 110-250 V/AC 110-240 V
PM100233.eps

Electronic card
PM103067.eps

For vacuum contactors CBX/CBX-C, a set of electronic card is equipped,


and has various options for supply voltage:
bbDC 24-60 V
bbDC 110-250 V/AC 110-240 V
PM103057.eps

Operations counter
For vacuum contactors CBX/CBX-C, an operations counter is equipped.

32
Vacuum contactor range CBX/CBX-C/CBXS-C series,
up to 12 kV fixed version

Dimensions

For CBX/CBX-C electromagnetic hold mechanical latch


Phase to phase distance mm 108 108
Size (W x D x H) mm 348 x 343 x 258 348 x 429 x 258

Weight kg 28 28

For electromagnetic hold mechanism


+1
343 -10
PM103075.eps

193 348
PM103073.eps

153.5
258

65 66

190 76 31 63.5 108 108


343 (support)

For mechanical latch mechanism


+0
429.5 -10
PM103076.eps

+1
343 -10
193 348
PM103074.eps

153.5
258

65 66

190 76 31 63.5 108 108


343 (support)

33
Vacuum contactor range CBX/CBX-C/CBXS-C series,
up to 12 kV fixed version

Electric circuit diagram


For CBX electromagnetic hold mechanism and DC & AC supply voltage:
PM103068.eps

1
Carte Electronique
CC1
Electronic Card 2

2
CC2 1 1 1 1 1 1 1 1 1 1
- + 1

Alimentation
Vdc ou Vac
Vdc or Vac supply

S11 S21 S12 S22 S13 S23 S14 S24 S15 S25

2 4 2 42 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4
L1 L2 L3

Main Control circuit 5 NO + 5 NC


circuit

For CBX mechanical latch mechanism and DC & AC supply voltage:


PM103069.eps

1
Carte Electronique
CC1
Electronic Card 2
1 TC
2
2 CC2 1 1 1 1 1 1 1 1 1 1
- + 1

Alimentation
Vdc ou Vac
Vdc or Vac supply

S11 S21 S12 S22 S13 S23 S14 S24 S15 S25

2 4 2 42 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4
L1 L2 L3

Main Control circuit 5 NO + 5 NC


circuit

34
Vacuum contactor range Spare parts

Spare parts *
Auxiliary switch
Right hand side switch
PM103079-red.eps

7.2 kV 400 A CBX Inductive load


12 kV 315 A CBX-C Capacitive load 5NO + 5NC
400 A CBXS-C Capacitive load

Coils
7.2 kV 400 A CBX Inductive load 24-60 Vdc
PM103053-red.eps

12 kV 315 A CBX-C Capacitive load

110-250 Vdc/110-240Vac

Mechanical latch
7.2 kV 400 A CBX Inductive load
PM103080-red.eps

12 kV 315 A CBX-C Capacitive load


400 A CBXS-C Capacitive load

Tripping coil
7.2 kV 400 A CBX Inductive load DC 24-30 V
PM100233-red.eps

12 kV 315 A CBX-C Capacitive load 48-60 V


400 A CBXS-C Capacitive load 110-250 V
AC 110-240 V

Electronic card
7.2 kV 400 A CBX Inductive load DC 24-30 V
PM103067-red.eps

12 kV 315 A CBX-C Capacitive load 110-250 V

AC 110-240 V

Operations counter
7.2 kV 400 A CBX Inductive load
PM103057-red.eps

12 kV 315 A CBX-C Capacitive load

Cover
7.2 kV 400 A CBX Inductive load
PM103087.eps

12 kV 315 A CBX-C Capacitive load


400 A CBXS-C Capacitive load

*: The spare parts could be ordered through the logistics of the manufacturing plant.

35
Vacuum contactor range CVX series, up to 12 kV
fixed version /
withdrawable version
Description of the device
PM103792.eps

The vacuum contactors CVX series include:


bbCBX/CBX-C contactor body
bbEnclosure for CVX-C-F/CVX-07/CVX-C-07
bbEnclosure for CVX-C-12
bbFuse holder for CVX series
bbDrawer for CVX Series (Not for CVX-C-F)
bbOption: Cradle

CBX/CBX-C contactor body


For the electromagnetic mechanism and mechanical latch mechanism:
bbMain and armature moulding with two pivot points
bbA steel mounting plate
bbThree vacuum switches
bbTwo closing coils
bbOne auxiliary contact block
bbOne electronic card and operations counter
And for the mechanical latch mechanism:
bbOne mechanical latch
bbOne tripping coil
PM103061.eps

Armature moulding

Pivot point Auxiliary block

Operations counter
Closing coil
Electronic card Stop pin

Fixing holes Opening springs

Steel mounting plate


PM103062.eps

Phase assembly

Main terminals (top) Moulded terminal


bar

Main moulding
Vacuum switches
Main terminals (bottom)

36
Vacuum contactor range
CVX series, up to 12 kV
fixed version /
withdrawable version
Enclosure for CVX-C-F/CVX-07/CVX-C-07
Mainly contains:
bbLV plugging-in plug
bbIndicators (C/O, fuse fusion, operations counter)
bbHandling bar
bbHandles (not for CVX-C-F)
bbOperation holes for crank (not for CVX-C-F)

PM103081.eps
Hardling bar
(only for handling)

LV plug

Operations counter hole


Fuse fusion indicator
C/O indicator

Handle

Hole for plugging-in


crank handle

Enclosure for CVX-C-12


Mainly contains:
bbLV plug
bbIndicators (C/O, fuse fusion, operations counter)
bbHandling bar
bbHandles
bbOperation holes for crank
PM103082.eps

Hardling bar
(only for handling)

LV plug

Operations counter hole

Handles Handle

C/O indicator

Hole for plugging-in


crank handle

37
Vacuum contactor range CVX series, up to 12 kV
fixed version /
withdrawable version
Fuse holder for CVX series
Mainly contains:
bbFuse holder
bb DIN fuse: 442 mm / 292 mm with extension. Or BS fuse: 454 mm / 410 mm /
305 mm.
bbThe fuses are not standard configuration

Fuse holder

PM103083.eps

442mm fuse
(not defaut configured)

CBX contactor body

(5) Drawer for CVX series (Not for CVX-C-F)


For CVX-07/CVX-C-07, the width is 350 mm.
For CVX-C-12, the width is 510 mm.

It mainly contains:
bbSpindle
bbSlide
bbWheels
bbLocking shaft
PM103084.eps

Spindle

Slide Locking shaft Wheels Spindle nut

38
Vacuum contactor range
CVX series, up to 12 kV
fixed version /
withdrawable version
Option: cradle
The cradle is used to enable the rack in and rack out functions of
contactor through rising shuttle mechanism interlocking and earthing
switch mechanism. This allows easy integration of CVX for the panel
builders.
Adaptation for:
bbCVX-07/CVX-C-07 (Width = 400 mm)
bbCVX-C-12 (Width = 650 mm)

PM103085.eps
PM103086.eps

Remark: the cradle could be ordered through the logistics of the


manufacturing plant. Please consult us for requirement details.

39
Vacuum contactor range CVX series, up to 12 kV
fixed version /
withdrawable version
Main characteristics
CVX-07 CVX-C-07 CVX-C-12 CVX-C-F
Electrical characteristics according to IEC 60470
Phase to phase distance mm 106 106 185 150
Rated voltage Ur kV 50/60 Hz 7.2 7.2 12 12
Insulation level power frequency withstand Ud kV 50/60 Hz 1 min 20/32 (1) 20/32 (1) 28/42 (1) 28
lightning impulse withstand Up kV peak 60 75 75 75
Rated operational current Ith A 400 (2) 400 (2) 315 (3) 315 (3)
Rated thermal current Ie A 400 (2) 400 (2) 400 (3) 400 (3)
Rated short-circuit breaking current Isc kA 6 (4) 6 (4) 4 (4) 4 (4)
Rated short-time withstand current Ik/tk kA/1 s 8 8 5 5
Rated peak withstand current Ip kA 20 20 12.5 12.5

Common characteristics according to IEC 60470


Switch frequency op./h 300
Mechanical endurance for electromagnetic mechanism op. 1,000,000
for mechanical latch mechanism op. 200,000
Electrical endurance at rated current op. 250,000
Consumption closing power W 500
Consumption holding power (magnet type) W 80
Closing time ms 120-200
Consumption opening power (mechanical type) W 240
Opening time ms 50-100
Operating rated ambient temperature °C -5/40
Average relative humidity over 24 h < 95%
over 1 month < 90%

(1) The value in the brackets is specific for the China market
(2) The rated current linked to the capacity of the fuse: 270 A with a maximum fuse size of 400 A
(3) The rated current linked to the capacity of the fuse: 195 A with a maximum fuse size of 250 A
(4) The rated current linked to the capacity of the fuse: 50 kA for the standard DIN fuse

40
Vacuum contactor range
CVX series, up to 12 kV
fixed version /
withdrawable version
Description of functions
PM103077.eps

Basic frame
For vacuum contactors CBX/CBX-C, the basic frame includes:
bb(1) Main moulding
(2) bb(2) Armature moulding
bb(3) Two pivot points
(1) (4) bb(4) A steel mounting plate
bb(5) Stop pin
(3) (5)
PM103078.eps

Power part
For vacuum contactors CBX/CBX-C, 3 pieces of power parts are assembled.
(7) For CBXS-C, 1 piece of power part is assembled.
Every piece of power part includes:
bb(6) Vacuum switch
bb(7) Main terminals (top)
bb(8) Main terminals (bottom)

For the vacuum switch type,


(6) bbVS3 is for CBX, the inductive load category
bbVS3-C is for CBX-C/CBXS-C, the capacitive load category

(8)

Closing coil
PM103053.eps

For vacuum contactors CBX/CBX-C, 2 pieces of closing coils are


assembled. Each closing coil has various options for supply voltage:
bbDC 24-60 V
bbDC 110-250 V/AC 110-240 V

41
Vacuum contactor range CVX series, up to 12 kV
fixed version /
withdrawable version
Auxiliary contact
PM103079.eps

For vacuum contactors CBX/CBX-C, various auxiliary contacts are


assembled and optional:
bb5NO + 5NC, right hand side assembly, without opening delay
bb5NO + 5NC, right hand side assembly, with 100 ms opening delay

Mechanical latch with tripping coil


PM103080.eps

For vacuum contactors CBX/CBX-C, the mechanical latch mechanism


with the tripping coil can be selected instead of the electromagnetic hold
mechanism. It consists of 1 mechanical latch and 1 tripping:
bbA mechanical latch part

A corresponding tripping coil with various options for the supply voltage:
bbDC 24-30 V
bbDC 48-60 V
bbDC 110-250 V/AC 110-240 V
PM100233.eps

Electronic card
For vacuum contactors CBX/CBX-C, an electronic card is equipped, and
has various options for the supply voltage:
PM103067.eps

bbDC 24-60 V
bbDC 110-250 V/AC 110-240 V

Operations counter
For vacuum contactors CBX/CBX-C, an operations counter is equipped.
PM103057.eps

42
Vacuum contactor range CVX series, up to 12 kV
fixed version /
withdrawable version
Dimensions

CVX-07/CVX-C-07
Phase to phase distance mm 106

Size (W x D x H) mm 350 x 720 x 780

Weight kg 70

731.5 359

PM103063.eps
106 106

330.5 774
178

212.5

14

67
346

CVX-C-12
Phase to phase distance mm 185

Size (W x D x H) mm 510 x 720 x 745

Weight kg 75

737 528.3
PM103064.eps

185 185

340 745
180

208

12.5

63.8
497.5

43
Vacuum contactor range
CVX series, up to 12 kV
fixed version /
withdrawable version
Dimensions

CVX-C-F
Phase to phase distance mm 150

Size (W x D x H) mm 450 x 631 x 566

Weight kg 60

450 631

PM103065.eps
75.2 150 150

218

566

268

Cradle’s for CVX-07/CVX-C-07 & CVX-C-12


Adapted CVX ranges A B C D E

For CVX-07/CVX-C-07 mm 474 1120 109 621 1021.2

For CVX-07 mm 724 1149.5 185 619.5 1065.2

A/2 E
PM103066.eps

C C

340

44
Vacuum contactor range CVX series, up to 12 kV
fixed version /
withdrawable version
Electric circuit diagram
For CVX-07/CVX-C-07/CVX-C-12 DC & AC supply voltage:

PM103070.eps
A5 A3 C3 B3 D13 A9 A11A13 A15 B9 B11 B13 B15 C13 C15 D11 D15 1

S001
alimentation Vdc ou Vac

S002
Carte Electronique

Vdc or Vac supply


1 Y1 E1 2 4 1

Electronic Card
TC 2 4
2 E2

S21
S12

S22

S13

S23

S14

S24

S15

S25
S11
1 1 1 1 1 1 1 1 1 1
4 2 244 2 2 4 4 2 2 4 4 2 2 4 4 2 2

S003
4
1
2 4

L1 L2 L3 A6 A4 C4 B4 D14 A10 A12 A14 A16 B10 B12 B14 B16 C14 C16 D12 D16

A B C D E F G H I J

Components:
A: Fuse contactor
B: Closing
C: (Options) tripping coil (for the mechanical latch mechanism)
D: (Options) Blocking magnet (handle)
E: (Options) Control power transformer (only for CVX-07/CVX-C-07)
F: Fuse blowing
G: Auxiliary contact: 5NO + 5NCa
H: Mandatory electrical interlock
I: Plug-in socket
J: Earthing

For CVX-C-F DC & AC supply voltage:


PM103071.eps

X0 1 7 3 5 11 21 13 23 15 25 17 27 19 29
S001

S002

1 1

Carte 1 2 4 4 2
Electronique TC
alimentation
Vdc ou Vac 2
Electronic
Card
S11

S21

S12

S22

S13

S23

S14

S24

S15

S25

Vdc or Vac
supply 1 1 1 1 1 1 1 1 1 1

4 2 2 4 4 2 2 4 4 2 2 4 4 2 2 4 4 2 2 4

L1 L2 L3 2 8 4 6 12 22 14 24 15 26 18 28 20 30

A B C D E

Explanations:
A: Fuse contactor
B: Closing
C: (optional) Tripping coil (for the mechanical latch mechanism)
D: Fuse blowing
E: Auxiliary contact: 5NO + 5NCa

45
Vacuum contactor range CVX series, up to 12 kV
fixed version /
withdrawable version
Fuse selection
The table in below contains a summary of the requirements of the
different types of fuse according to the type of load:

Type of load Tranformer Motor Capacitors


Single bank Multiple step banks
Ordre of magnitude 4 to 100 A 100 to 250 A 100 to 250 A
of fuse rating

Selection rules IA < IN transf. < IB Fixed by IP and tD IN bank x 1.7 < IN fuse
IN motor x 1.2 Insc fixed by î. t

Ip No specification Low High


t ≈ 1 ms

I fusing 0.1 s High No specification High (t ≈ 0.1 s) No specification

I fusing 10 s Low for close-up protection High Low for close-up protection

I3 No specification

UN 0 to 36 kV 0 to 12 kV 0 to 36 kV

These specifications can be used to plot the ideal time/current characteristic


for a fuse according to its use (refer to the diagram in below). This diagram
clearly shows the requirement parameters for each type of protected load.
It also clearly illustrates the relative insignificance of the IN value of a fuse
when it is taken alone as a selection criterion (as is unfortunately too often
the case).

Ideal time/current characteristics for protecting:

a) a transformer. b) a motor. c) a capacitor.

t(s) t(s) t(s)


PM103072.eps

a b c

100 100 IN 100


I3 low 100 to 250 A
high-speed fusing I3 low
10 10 I 10 s 10 high-speed fusing
high
IN 0 to 100 A
1 1 1

0.1 I 0.1 s 0.1 0.1 ////////////////


high
high
Ʈ = 1 ms/0.1 s peak
IP low
0.01 0.01 0.01
102 103 104 I (A) 102 103 104 I (A) 102 103 104 I (A)

46
Vacuum contactor range Spare parts

Spare parts *
Auxiliary switch
12 kV 315 A Capacitive load 5NO + 5NC Right hand side switch
PM103079-red.eps

Coils
12 kV 315 A Capacitive load 24-60 Vdc
PM103053-red.eps

110-250 Vdc/110-240Vac

Mechanical latch
12 kV 315 A Capacitive load
PM103080-red.eps

Tripping coil
12 kV 315 A Capacitive load DC 24-30 V
PM100233-red.eps

48-60 V
110-250 V
AC 110-240 V

Electronic card
12 kV 315 A Capacitive load DC 24-30 V
PM103067-red.eps

110-250 V
AC 110-240 V

Operations counter
12 kV 315 A Capacitive load
PM103057-red.eps

*: The spare parts could be ordered through the logistics of the manufacturing plant.

47
CPX/CPX-C,
up to 3.6 kV fixed version

Fixed vacuum contactor, CPX/CPX-C Quantity


PM103787.eps

Load category Capacitive Inductive


Rated voltage Ur 3.6 kV

Rated operational current 400 A 315 A

Rated short-circuit breaking current Isc 6 kA 4.5 kA

Frequency 50 Hz 60 Hz

Vacuum contactor options

Closing coils (2 pieces in each contactor) DC 24 V DC 48 V


DC 60 V
DC 110 V AC 110 V
DC 125 V AC 120 V
DC 220 V AC 220 V
DC 250 V AC 240 V

Contactor mechanism type Electromagnetic hold Mechanism latch

Tripping coil (1 piece in each contactor) DC 24-30 V DC 48-60 V


(only for mechanical latch mechanism) DC 110-250 V
AC 110-240 V

Auxiliary contact
For electromagnetic hold mechanism 2NO + 1NC, left side
4NO + 4NC, left & right side 4NO + 4NC, L side & R facing
For mechanical latch mechanism 2NO + 3NC, left side
5NO + 5NC, left & right side 5NO + 5NC, L side & R facing

Gauge YES NO

Technical manual YES NO

Remark: Only one of the boxes (ticked or filled by the needed value) has to be
considered between each horizontal line.

48
Order forms
CLX,
up to 7.2 kV fixed version

Fixed vacuum contactor, CLX


PM103789.eps

Quantity

Load category Inductive


Rated voltage Ur 7.2 kV

Rated operational current 400 A

Rated short-circuit breaking current Isc 6 kA

Frequency 50 Hz 60 Hz

Vacuum contactor options

Closing coils (2 pieces in each contactor) DC 24-60 V


DC 110-250 V/AC 110-240 V

Contactor mechanism type Electromagnetic hold Mechanism latch

Tripping coil (1 piece in each contactor) DC 24-30 V


(only for mechanical latch mechanism) DC 48-60 V
DC 110-250 V/AC 110-240 V

Electronic card DC 24-60 V


DC 110-250 V
AC 110-240 V

Auxiliary contact 5NO + 5NC right side, without opening delay


5NO + 5NC, right side assembly, with 100 ms opening delay

Gauge YES NO

Technical manual YES NO

Remark: Only one of the boxes (ticked or filled by the needed value) has to be
considered between each horizontal line.

49
Order forms
CBX/CBX-C/CBXS-C,
up to 12 kV fixed version

Fixed vacuum contactor, CBX/CBX-C/CBXS-C Quantity


PM103784.eps

Phase numbers Single phase Three phases


Load category Capacitive Inductive
Rated voltage Ur 7.2 kV 12 kV

Rated operational current 315 A 400 A

Rated short-circuit breaking current Isc 4 kA 6 kA

Frequency 50 Hz 60 Hz

Vacuum contactor options

Closing coils (2 pieces in each contactor) DC 24-60 V


DC 110-250 V/AC 110-240 V

Contactor mechanism type Electromagnetic hold Mechanism latch

Tripping coil (1 piece in each contactor) DC 24-30 V


(only for mechanical latch mechanism) DC48-60 V
DC 110-250 V/AC 110-240 V

Electronic card DC 24-60 V


DC 110-250 V
AC 110-240 V

Auxiliary contact 5NO + 5NC right side, without opening delay


5NO + 5NC, right side assembly, with 100 ms opening delay

Interlock between 2pcs contactors Between 2pcs magnetic hold type


Between 2pcs mechnical latch type

Position indicator YES


NO

Gauge YES NO

Technical manual YES NO

Remark: Only one of the boxes (ticked or filled by the needed value) has to be
considered between each horizontal line.

50
Order forms CVX series,
up to 12 kV fixed version /
withdrawable version
Fixed vacuum contactor, CVX series
PM103792.eps

Quantity

Phase numbers Fixed type Withdrawable type


Load category Capacitive Inductive
Rated voltage Ur 7.2 kV 12 kV

Rated operational current 315 A 400 A

Rated short-circuit breaking current Isc 4 kA 6 kA

Frequency 50 Hz 60 Hz

Vacuum contactor options

Closing coils (2 pieces in each contactor) DC 24-60 V


DC 110-250 V/AC 110-240 V

Contactor mechanism type Electromagnetic hold Mechanism latch

Tripping coil (1 piece in each contactor) DC 24-30 V


(only for mechanical latch mechanism) DC 48-60 V
DC 110-250 V/AC 110-240 V

Electronic card DC 24-60 V


DC 110-250 V
AC 110-240 V

Auxiliary contact 5NO+15NC rithg side, without opening delay


5NO+5NC rithg side, with 100ms opening delay

Fuse holder For BS 454mm For DIN 442mm


(BS fuse is only for 7.2kV application) For BS 410mm For DIN 292mm with
For BS 410mm fuse extension

Voltage transformer suit AC 6.6kV/110V AC 3.3kV/230V


AC 6.6kV/230V AC 6.9kV/220V
AC 3.3kV/110V AC 4.16kV/120V
AC 4.16kV/110V

Electronic card YES


NO

Interlock with PIX-M door YES


NO

Truck blocked when magnet energized DC 24V DC 220-230V


(Only for withdrawable CVX) DC 48V AC 110V
DC 110V AC 127V
DC 125V AC 220-230V

Truck blocked when magnet unenergized DC 24V DC 220-230V


(Only for withdrawable CVX) DC 48V AC 110V
DC 110V AC 127V
DC 125V AC 220-230V

Gauge YES NO

Technical manual YES NO

Remark: Only one of the boxes (ticked or filled by the needed value) has to be
considered between each horizontal line.

51
Notes

52
ART.XXXXXX ©2014 - Schneider Electric - All rights reserved

Make the most of your energy™


www.schneider-electric.com

Schneider Electric Industries SAS


35, rue Joseph Monier As standards, specifications and designs change from
CS 30323 time to time, please ask for confirmation of the
92506 Rueil Malmaison Cedex information given in this publication.
10-31-1247
France

RCS Nanterre 954 503 439 Publication: Schneider Electric Industries SAS  his document has been
T
Capital social 896 313 776 € Photos: Schneider Electric printed on ecological paper.
www.schneider-electric.com Publishing: Altavia St Etienne

NRJED313585EN 09-2014

You might also like