Magnetic Particle Testing Level-II Specific

(Reference Document ASME Section-V, Article-7 & ASME Sec.VIII App.6)

Date:_______________________________________
Name:________________________________________

ID# :_______________________________________

Answer all questions. Circle appropriate answer


1. How many shots are required when using a a. 8800 - 11000 Amps
longitudinal magnetic field technique for the b. 1000 - 3200Amps
part length of 45 inches? T-753.2 c. 22500 Amps
a. 3 shots d. None of the above
b. 2 shots 7. Which of the following is acceptable? App8:
c. 1 shot 8.4
d. 2.5 shot a. relevant linear indications;
2. Type of current required to do longitudinal b. relevant rounded indications greater than
magnetic field test by coil method is: T-753.2 3/16 in.(5 mm);
a. AC or Rectified AC c. three relevant rounded indications in a
b. DC or Rectified AC line separated by 1/ 16 in. (1.5 mm) or
c. DC or AC less (edge to edge).
d. DC or Rectified DC d. four or more relevant rounded
3. The examiner’s vision requirement shall meet indications in a line separated by 1/ 16
which of the following? App.8(8.2) in. (1.5 mm) or less (edge to edge).
a. J2 8. Which of the following is not acceptable?
b. J2 at 300mm App8: 8.4
c. J1 at 300mm a. relevant linear indications;
d. AWS-D1.1 b. relevant rounded indications greater than
e. All of the above 1/16 in.(1.5 mm);
4. The definition of linear indication is: App.8: c. three relevant rounded indications in a
8.3a line separated by 1/ 16 in. (1.5 mm) or
a. Circular or elliptical shape indication less (edge to edge).
with the length equal to or less than three d. all of the above
times the width 9. Post Cleaning should occur; T-779
b. An indication having a length less than a. after residual bath dried
three times the width. b. prior to complete drying of residual bath
c. An indication having a length greater c. prior to NDT
than three times the width. d. As soon as practical using a process that
d. Two or more round indications separated does not adversely affect the part
by less than the smallest indication. 10. The ferromagnetic particle shall: T-731
5. Relevant indication is: a. be able to induce magnetism in a
a. caused by excessive magnetizing current ferromagnetic body by an outside
b. caused by structural design magnetizing force
c. result from discontinuity within the test b. be fnely divided ferromagnetic particles
part c. have High Retentivity
d. an indication result from leakage field d. have Low permeability
6. A eleven inch diameter and 22” long shaft 11. What is relevant indication?App.8: 8.3
has to be tested with circular magnetism a. Only indications with major dimensions
(direct contact technique), the current require greater than 3/16 in. (5 mm) shall be
is: T-754.1 considered relevant.
b. An indication having a length greater 16. Demagnetization: T-778
than three times the width a. Shall be required following final
c. Only indications with major dimensions magnetic particle inspection.
greater than 1/16 in. (1.5 mm) shall be b. is always necessary.
considered relevant. c. can be performed only with AC.
d. Only indications with major dimensions d. shall be performed when residual
greater than 1/8 in. (3 mm) shall be magnetism in the part could interfere
considered relevant. with subsequent processing or usage
12. Which of the following type yokes can be 17. The formula 45000/(L/D)is used to: T-753.2b
used for MPI? T-755 a. produce circular magnetism
a. AC or DC yokes b. longitudinal magnetism
b. AC, DC or Permanent yokes c. produce vector magnetism
c. DC or Permanent yokes d. toroidal magnetism
d. 3 Phase AC yokes 18. The field strength adequacy is determined; T-
13. Any indication believed to be nonrelevant; T- 764.2
777 a. using an ammeter
a. shall be accepted. b. using a special carbon steel/copper plate
b. shall be reexamined. field indicator
c. shall be regarded as relevant. c. using a voltmeter
d. nonrelevant indications shall be proven d. using a multimeter
as false or nonrelevant. 19. A rounded indication is: App.6: 6.3b
14. A non-relevant indication: T-764.2 a. having a length less than three times the
a. is caused by insufficient magnetic field width
b. result from excessive magnetizing b. laps
current c. having a length more than three times the
c. variation in hardness values width
d. variation in material density d. seams
15. A square bar of 3”x3” and 20” length has to 20. Which of the following is an essential
be tested with 5 turn AC coil, current variable?
required is: T-753.2 a. Magnetizing technique
a. 1900Amps b. Shape or size of the examination object
b. 1050 Amps c. Demagnetizing technique
c. 2400 - 3000 Amps d. Temperature (within those specified by
d. 1500 - 2400 Amps manufacturer or as previously qualified).
Test Set Number: 1
Test Name: MT L2 Specific
1. A 6. D 11. C 16. D
2. B 7. C 12. B 17. B
3. B 8. D 13. D 18. B
4. C 9. D 14. B 19. B
5. C 10. B 15. B 20. A