Download as pdf or txt
Download as pdf or txt
You are on page 1of 10

INTERACTIVE SCHEMATIC

Bookmarks X
*This document is best viewed at a
Options
screen resolution of 1024 X 768.
Features
Cover Page
To set your screen resolution do the following:
Tables RIGHT CLICK on the DESKTOP.
Component Select PROPERTIES.
Connector
CLICK the SETTINGS TAB.
Schematic
Machine Views
MOVE THE SLIDER under SCREEN RESOLUTION
Chassis View until it shows 1024 X 768.
Cab View CLICK OK to apply the resolution.
Engine View
*Due to different monitor sizes and PDF reader preferences
The Bookmarks panel will allow you to there may be some variance in linked schematic locations
quickly navigate to points of interest.

Click here to save a copy of


EC-C2 E-C60 this interactive schematic
EC-C3
to your desktop
E-C61

VIEW ALL CALLOUTS

EC-C1
When only one callout is showing on a
machine view, clicking on this button will
Click on any text that is BLUE and make all of the callouts visible. This
underlined. These are hyperlinks button is located in the top right corner
that can be used to navigate the of every machine view page.
schematic and machine views.

ELECTRICAL SYMBOLS BASIC HYDRAULIC


HOTKEYS (Keyboard Shortcuts) COMPONENT SYMBOLS
T

Pressure Temperature Level Flow


Switch Switch Switch Switch Circuit Breaker Pump
Variability
FUNCTION KEYS or Motor

Click here to view the


Spring
Zoom In “CTRL” / “+” Schematic Symbols
Fluid
Conditioner (Adjustable)

Zoom Out “CTRL” / “-” and Definitions page

Fit to Page “CTRL” / “0” (zero)


Hand Tool “SPACEBAR” (hold down)
Find “CTRL” / “F”
Search “CTRL” / “SHIFT” / “F”
SCHEMATIC SYMBOLS AND DEFINITIONS

VALVES INTERNAL PASSAGEWAYS PUMPS BASIC HYDRAULIC


ENVELOPES FLOW IN ONE
DIRECTION
FLOW ALLOWED IN
EITHER DIRECTION
PARALLEL
FLOW
CROSS
FLOW
FIXED DISPLACEMENT
COMPONENT SYMBOLS

One Position Two Position Three Position Unidirectional Bidirectional Pump


Infinite Two Three Variability
Positioning Position Position or Motor
PORTS VARIABLE DISPLACEMENT
NON- COMPENSATED

CYLINDERS Fluid Spring


(Adjustable)
Two-way Three-Way Four-Way Conditioner
Unidirectional Bidirectional
CONTROL
AB
MOTORS
AB
Single Acting Double Acting
Pressure
FIXED DISPLACEMENT Spring
P T P T Compensation
Normal Position Shifted Position Infinite Position

CHECK
ACCUMULATORS Unidirectional Bidirectional Control Line Restriction
Valves (Variable)
VARIABLE DISPLACEMENT
Basic Spring Shuttle NON- COMPENSATED
Pilot
Symbol Loaded Line Restriction
Controlled Spring Loaded Gas Charged Restriction
(Fixed)

Unidirectional Bidirectional

MAIN AUX.

PILOT CONTROL
Line Restriction 2-Section
RELEASED PRESSURE ROTATING SHAFTS Variable and Pressure
Compensated
Pump

Unidirectional Bidirectional
External Return Internal Return
Attachment Pump: Variable and
REMOTE SUPPLY PRESSURE Pressure Compensated

Internal Hydraulic Pneumatic


Simplified Complete Supply Pressure Energy Triangles

COMBINATION CONTROLS
LINES MEASUREMENT

Solenoid Solenoid Solenoid Solenoid and Servo Thermal Detent Crossing Joining
or Manual and Pilot Pilot or Manual Pressure Temperature Flow

MANUAL CONTROL FLUID STORAGE RESERVOIRS

Push-pull Lever Manual Shutoff General Manual Push Button Pedal Spring Vented Pressurized Return Above Fluid Level Return Below Fluid Level

HYDRAULIC SYMBOLS - ELECTRICAL ELECTRICAL SYMBOLS


G
M T

Pressure Temperature Level Flow


Transducer Transducer Generator Electric Pressure Pressure Switch Temperature Electrical
Switch Switch Switch Switch Circuit Breaker
(Fluid) (Gas / Air) Motor Switch (Adjustable) Switch Wire

BASIC ELECTRICAL COMPONENT SYMBOLS HARNESS AND WIRE SYMBOLS


Wire, Cable, or Harness Assembly Identification:
Fuse: A component in an electrical circuit that will open the circuit if too much current flows through it. Includes Harness Identification Letters and Harness
Connector Serialization Codes (see sample).
Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The circle indicates
that the component has screw terminals and a wire can be disconnected from it.
AG-C4 L-C12
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.). 111-7898 3E-5179
No circle indicates that the wire cannot be disconnected from the component. Part Number: for 1
Connector Plug
Ground (Wired): This indicates that the component is connected to a grounded wire. 2
The grounded wire is fastened to the machine.
Plug Receptacle
Pin or Socket Number
Ground (Case): This indicates that the component does not have a wire connected to ground.
It is grounded by being fastened to the machine. Harness Identification Letter(s): (A, B, C, AA, AB, AC, ...)

Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the contacts of Harness Connector Serialization Code: The "C" stands for
"Connector" and the number indicates which connector in the
a normally open reed switch; it opens the contacts of a normally closed reed switch.
harness (C1, C2, C3, ...)
L-C12
Sender: A component that is used with a temperature or pressure gauge. 3E-5179
The sender measures the temperature or pressure.
T Its resistance changes to give an indication to the gauge of the temperature or pressure. 5A
Component
Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity. Fuse (5 Amps) 9X-1123 Part Number
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close the switch part of the relay. 325-AG135 PK-14
Harness identification code:
This example indicates wire group 325, Wire Gauge
Solenoid: A solenoid is an electrical component that is activated by electricity. wire 135 in harness "AG". Wire Color
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close a valve or move a piece of metal that can do work. 1 Deutsch connector: Typical representation
of a Deutsch connector. The plug contains all
2 sockets and the receptacle contains all pins.
Magnetic Latch Solenoid: An electrical component that is activated by electricity and held latched by a
permanent magnet. It has two coils (latch and unlatch) that make electromagnet 1 Sure-Seal connector: Typical representation
when current flows through them. It also has an internal switch that places of a Sure-Seal connector. The plug and receptacle
2 contain both pins and sockets.
the latch coil circuit open at the time the coil latches.
UENR5457-03
December 2016

326D2 Excavator
Hydraulic System
KGY1-Up
REC1-UP
MGW1-UP
NBX1-UP
JFL1-UP
XAM1-UP
MZH1-UP
LCW10001-UP
HM41-UP

© 2016 Caterpillar CAT, CATERPILLAR, their respective logos, “Caterpillar Yellow”, and the POWER EDGE trade dress as well as
All Rights Reserved corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.
COMPONENT LOCATION
Part Machine Schematic
Description
Number Location Location
Accumulator Gp 164-6981 1 B-5
Cyilinder Gp - Boom Note A 2 F-2
Cyilinder Gp - Bucket Note A 3 F-2
Cyilinder Gp - Stick Note A 4 F-2
Filter Gp - Oil 188-4140 5 A-5
Filter Gp - Oil (Case Drain) 289-8194 6 A-4
Filter Gp - Oil (Pilot) 158-8987 7 A-4
Motor Gp - Swing 334-9970 8 F-6
Motor Gp - Travel (LH) 209-5992 9 F-5
Motor Gp - Travel (RH) 209-5992 10 F-3
Pump Gp - Pistion (Main) 422-1294 11 B-2
Sensor As - Pressure (Drive Pilot) 338-6970 12 C-1
Sensor As - Pressure (Drive) 434-3436 13 A-3
Sensor As - Pressure (Idler Pilot) 338-6970 14 C-6
Sensor As - Pressure (Idler) 434-3436 15 B-3
Swivel Gp 234-4440 16 E-4
Valve Gp - Check (Oil Cooler Bypass) 173-4672 17 A-8
Valve Gp - Load Control (Boom) 255-5683 18 E-2
Valve Gp - Load Control (Stick) 255-5680 19 D-5
Valve Gp - Main Control 259-7380 20 D-1
Valve Gp - Pilot Control (Left Joystick) 297-0533 21 C-8
Valve Gp - Pilot Control (Right Joystick) 297-0532 22 C-7
Valve Gp - Pilot Manifold 215-5037 23 B-7
Valve Gp - Pilot Travel 369-8502 24 E-8
Valve Gp - Pressure Reducing (Boom, Swing Priority) 310-0210 25 B-4
Valve Gp - Shuttle 164-6979 26 C-4
Valve Gp - Shuttle (Cab) 185-0462 27 B-8
Valve Gp - Swing Cushion 322-8716 28 E-6
Valve Gp - Travel Couterbalance (LH) 322-8714 29 E-5
Valve Gp - Travel Couterbalance (RH) 322-8714 30 E-4
Valve Gp - Solenoid (Heavy Lift - Option) 352-7176 31 B-5
Sensor As - Pressure (Implement) 454-5075 32 B-8
Sensor As - Pressure (Left Travel) 454-5075 33 D-8
Sensor As - Pressure (Right Travel) 454-5075 34 D-7
Note: Check Part Number In The Parts Manual For Your Specific Machine.
Note A: Refer To Parts Manual For Your Specific Machine.
TAP LOCATION

Tap Schematic
Description
Number Location
AA Pilot Pump Delivery Pressure A-4
BB Idler Pump Delivery Pressure B-3
CC Drive Pump Delivery Pressure A-3
DD Drive Pump Power Shift Pressure B-2
EE Idler Pump Power Shift Pressure A-2
FF Case Drain Pressure A-2
SOS Oil Sampling Port A-4
8 7 6 5 4 3 2 1

SWG SWING MOTOR (3) BUCKET CYLINDER (4) STICK CYLINDER


(9) MOTOR GP (10) MOTOR GP
PRKG BK TRAVEL (RH)
CONTROL (8) MOTOR GP TRAVEL (LH)
PG 209-5992
SWING 209-5992
DR 334-9970
SWG 482-6393
MOTOR
F DRAIN F
MU
MU
Pp3 Pp3
A1 B1 AG BG
DR
T1 AR3 BR3
T1 AL3 BL3

A1 B1 T2 T2
DR
(2) BOOM CYLINDERS

(28) VALVE GP MA MB MB MA
SWING CUSHION
158-9085
(29) VALVE GP
SWING CUSHION
(FINE SWING)
322-8716
A(R) B(L) A B B A
A(R) B(L) AR4 BR4
(29) VALVE GP - TRAVEL (30) VALVE GP - TRAVEL
E BL2 AL2 E
COUNTERBALANCE (LH) COUNTERBALANCE (RH)
BL2 AL2 322-8714
322-8714
(24) VALVE GP AL1 BL1 AR1 BR1
PILOT (TRAVEL)
TP (BKWD) (FWD) (BKWD) (FWD)
369-8502
TT (16) SWIVEL GP (18) VALVE GP
SWG
(19) VALVE GP MOTOR 234-4440 LOAD CONTROL
TRAVEL(L) TRAVEL(R)
LOAD CONTROL (STICK) DRAIN (BOOM)
255-5680 255-5683
DRAIN 2 SPEED
BR5 SDr BL3 AL3 FILTER TRAVEL AL4 BDr BR4 BR5 AR5
CONTROL
aL4 SPi BPi

SP3 SP2 BP3 BP2


aL4-2 AR5 aL2 aL1 AR4
BKWD FWD FWD BKWD
T3 AL4 aL2-2 Pi1
T1 T5 T2 T4 T6

C/V - T AL2 AL1 Di4 Pi4 BR1 AR1 BR3 AR3 aR4 R3
aL1 bL1 bR1 aR1
D aL3 BL2 BL1 aR1 aR3 aR5 D
T SP1 ST aR2 BR2 AR2 Pi1 BP1 BT (20) VALVE GP
BL3 (IN)
MAIN CONTROL
(33) SENSOR AS 5 6 3 2 (UP) R2 (L) (BKWD) (BKWD) (CLOSE) (DOWN) BR4 R1 (IN)
(34) SENSOR AS 259-7380
4 1
PRESSURE PD-Dr PRESSURE 285-1349 (HEAVY LIFT)
(LEFT TRAVEL) (RIGHT TRAVEL)
NOTE A PD-Pi
4 1 NOTE A
5 6 3 2

(21) VALVE GP (22) VALVE GP


PILOT CONTROL PILOT CONTROL
(LEFT JOYSTICK) (RIGHT JOYSTICK)
297-0533 JLP JRP 297-0532
JLT JRT
STICK SWING BUCKET BOOM
BOOM(2)

ATCH

BUCKET
SWING

TRAVEL(R)

BOOM(1)

STICK(2)
TRAVEL(L)
STICK(1)
(12) SENSOR AS - PRESSURE
(NFC-DRIVE PUMP)
C OUT IN R L OPEN CLOSE DOWN UP (OUT) (R) (FWD) (FWD) (OPEN) (UP) (OUT) 338-6970 C
JL1 JL3 JL2 JL4 JR4 JR2 JR3 JR1
bL2-2 bR2
Pi5 bR1
Di1
HL bL4 Di2 Pi2 bL3 Pi3 bL2 bL1 DST PL PR bR3 bR4 bR5 HR
(14) SENSOR AS - PRESSURE Di3
(NFC-IDLER PUMP)
A1 A2 A3 A4 A7 338-6970 IF HEAVY LIFT (26) VALVE GP NOTE A:
A5 A6 A8
(31) VALVE GP IS EQUIPPED SHUTTLE 309-5769 PRESSURE SWITCH
SOLENOID (HEAVY LIFT) 164-6979 (15) SENSOR AS -PRESSURE OR
352-7176 (IDLER PUMP) 454-5075 PRESSURE SENSOR
(27) VALVE GP RR FR
SHUTTLE (CAB) aL2-2 bL2-2 434-3436
185-0462 2 SPEED IF HEAVY LIFT U
464-7318 TRAVEL IS EQUIPPED HL-Pi (25) VALVE GP Do not operate or work on this product unless you have
read and understood the instruction and warnings in the
CONTROL aL4-2 aR5 Pi3 PRESSURE (11) PUMP GP relevant Operation and Maintenance Manuals and
B1 B2 B3 B4 C B5 B6 B7 B8 relevant service literature. Failure to follow the instruc-
(32) SENSOR AS A P REDUCING PISTON (MAIN) tions or heed the warnings could result in injury or
Pi5
PRESSURE (IMPLEMENT) aL2 Pi4 MF-P Di4 PD-Pi (BOOM,SWING BB 272-6957
422-1294
death. Proper care is your responsibility.

NOTE A T PRIORITY)
bL2 SPi G2 LINE PATTERNS
HL-Pi B1 A1 B2 A2 310-0210
aR3 bR3 HL-Dr M2 Pressure Line
bR5 Pi2 PD-Dr Di3
B aL4 Pilot / Load Sensing Pressure B
PiI bL3 P2 Pi1 P-IN PSA2 DR1 PSA1 DST
bL4 aL3 PRV-PI IF HEAVY LIFT Drain / Return Lines
BPi bR4 IS EQUIPPED Pn2
T-OUT2 DR2 PL HL Air Line

aR4 (23) VALVE GP PRV-Dr Component Group


T Ps2
(TRAVEL)

A2
(SWING)

PILOT MANIFOLD P1 P2 DD CALLOUTS


215-5037 PsM2
NO.1

NO.2

(17) VALVE GP
(1) ACCUMULATOR GP YY Taps (Pressure, Sampling, Sensor - by letter)
(LOCK)

CHECK (OIL
NO.3

MU COOLER BYPASS) 164-6981 DL DL D Connectors (By letter)

R3 PRV-P1 PRV-P2 S3
173-4672 Pm Callout Number
(Machine Location from (52) VALVE GP - CONTROL
Component
Name
Component LocationsTable)
C 138-1234 Part Number

B PRV-P2 S1 Dr
P1 (6) FILTER GP OIL HYDRAULIC CIRCUIT COLOR DESCRIPTIONS
SDr (CASE DRAIN) DRAIN
G
A
PAC 289-8194
FILTER FF PILOT PUMP OUTPUT
DRIVE PUMP OUTPUT
DrM
BDr LEFT TRAVEL CONTROL CIRCUIT
POWER SHIFT CONTROL CIRCUIT
D E F DR3 DR4 Pi2 DR5 T-OUT1 DR6 PsM1
HL-Dr SUPPLY LINE
C/V T STICK CYLINDER CONTROL CIRCUIT

PRV-Dr SWG MF-TANK


Di1
MF-P EE ATTACHMENT CONTROL CIRCUIT
SWING CONTROL CIRCUIT
IF HEAVY LIFT Ps1
PRKG BK A1 DRAIN / RETURN LINE
IS EQUIPPED CONTROL Di2 SWING BRAKE CONTROL CIRCUIT
IDLER PUMP OUTPUT
OUT IN PR TRAVEL SPEED CONTROL CIRCUIT
A MF-TANK Ps HR BUCKET CYLINDER CONTROL CIRCUIT A
Pn1 RIGHT TRAVEL CONTROL CIRCUIT
BOOM CYLINDER CONTROL CIRCUIT
Ps HEAVY LIFT CONTROL CIRCUIT
Pi
T

PG PC M1
(5) FILTER GP OIL A3 G1 THIS SCHEMATIC IS FOR THE 326D2 Excavator Hydraulic System
188-4140 (7) FILTER GP
MEDIA NUMBER: UENR5457-03
OIL (PILOT)
AA SOS (13) SENSOR AS CC SCHEMATIC PART NUMBER: 255-5782, CHANGE: 01, VERSION: HE
158-8987 PRESSURE SCHEMATIC PART NUMBER: 477-8801, CHANGE: 00, VERSION: HE
(DRIVE) Components are shown installed on a fully operable machine with the key and engine off.
434-3436 Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.

8 7 6 5 4 3 2 1
CAB - TOP VIEW
VIEW ALL CALLOUTS
33 24 34

21 27 32 22
MACHINE - RIGHT REAR VIEW
VIEW ALL CALLOUTS

2
4

28

16
8

29
30
10
MAIN VALVE - VIEW FROM REAR
VIEW ALL CALLOUTS

12
14

20

19

18
17

25
31
BEHIND
PILOT VALVE

26 23 1
NOT
SHOWN
PUMP - RIGHT SIDE VIEW
VIEW ALL CALLOUTS
CC DD BB 6 5

EE

AA

SOS

13 11 15 FF

You might also like