Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

A B C D A B C D

12000 12000
4000 4000 4000 4000 4000 4000
B GENERAL NOTES
A A SCALE 1:100 MTS.
2 2
p p

4 4
h i

f g j k l
1. ALL ELECTRICAL WORKS SHALL COMPLY IN ACCORDANCE WITH THESE PLANS AND
3000

3000
Sh Si SPECIFICATIONS. THE APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE
PB PHILIPPINE ELECTRICAL CODE (P.E.C.) . THE RULES AND REGULATION OF THE LOCAL
Sfg Sjkl ENFORCING AUTHORITY AND THE REQUIREMENTS OF THE LOCAL POWER COMPANY. THE
3 up
S3wn 3 dn
S3wn Sm
PB
ELECTRICAL WORKS SHALL BE DONE UNDER THE IMMEDIATE SUPERVISION OF A DULY
REGISTERED ELECTRICAL ENGINEER.
2
b a o m
2. THE ELECTRICAL SERVICE POWER IS 1 - PHASE, 2 -WIRE, 230 VAC, 60Hz .
9000
3000

9000
3000
n
3. SERVICE ENTRANCE SHALL BE IN RMC OR RSC CONDUIT. SUB FEEDERS SHALL BE ON RSC CONDUIT.
PB THE TYPE OF WORKS TO BE EMPLOYED SHALL BE IN THE PVC WIRING IN THE CEILING, CONCRETE,
1
Sbcd Sa Sop SLABS, PARTITIONS AND DOUBLE WALLINGS.
2 Se 2 W W W
4. ALL WIRES SHALL BE COPPER AND THERMO PLASTIC INSULATED TYPE "THHN" UNLESS
OTHERWISE INDICATED IN THE PLAN . THE MINIMUM SIZE OF WIRE FOR POWER AND
1 1 1
d c e LIGHTING CIRCUIT HOME RUN SHALL BE 3.5 mm² AND INSULATED FOR 600 VOLTS .
3000

3000
SMALLEST RACEWAY SHALL BE 20 mmØ TRADE / NOMINAL SIZE .
5. ALL OUTLET BOXES SHALL BE GALVANIZED GAGE NO. 16 DEEP TYPE WITH FACTORY
KNOCKOUTS .
1 1 6. ALL MATERIALS TO BE USED SHALL BE BRAND NEW AND APPROVED TYPE FOR THE
PARTICULAR LOCATION AND PURPOSE OF USAGE .
7. GROUNDING SYSTEM SHALL BE PROVIDED TO ALL LIGHTING AND POWER CIRCUITS AS
PER PHILIPPINE ELECTRICAL CODE REQUIREMENT
8. MOUNTING HEIGHT OF WIRING DEVICES SHALL BE AS FOLLOWS:.
GROUND FLOOR SECOND FLOOR a . LIGHT SWITCH - 1.30 M ABOVE FINISH FLOOR
b. CONVENIENCEOUTLET - 0.30M ABOVE FINISH FLOOR
A LIGHTING LAYOUT B LIGHTING LAYOUT c. PANEL BOARD - 1.7 0M ABOVE FINISH FLOOR
A A SCALE 1:100 MTS. A A SCALE 1:100 MTS. 9. ALL RECEPTACLES LOCATED FROM THE KITCHEN, BATHROOMS AND OUTDOORS ARE GFCI PROTECTED
2 2 2 2 AND ALL RECEPTACLES FROM BED ROOMS ARE AFCI PROTECTED AS PER PEC REQUIREMENT.
10. ALL FEEDERS AND BRANCH CIRCUIT SHALL BE INSTALLED AS INDICATED ON PLAN, INDIVIDUAL
CIRCUIT HOME RUNS TO PANEL BOARD SHALL NOT BE COMBINED IN THE SAME RACEWAY UNLESS
OTHERWISE INDICATE OF THE PLAN.
A B C D A B C D
12000 12000
4000 4000 4000 4000 4000 4000

B LEGEND
A A SCALE 1:100 MTS.
2 2

4 4
3000

3000

FLUORESCENT LAMP
PB
LIGHT BULB
3 up
3 dn
PB
4
Sh SINGLE GANG SWITCH
PB
PANEL BOARD
MPB
4
Sfg
9000
3000

9000
3000

2.0hp SBH
TWO GANG SWITCH
MPB MPB MPB PB
MPB MPB
MPB
7.5hp PMS
1 2
2.0hp SCH
3
2.0hp SCH
5
ACU
2.0hp
5 6
2.0hp ORS
Sbcd THREE GANG SWITCH MACHINE PANEL BOARD
2 2
HRM

PB
S3wn THREE WAY SWITCH
3 MDP
CONVENIENCE OUTLET MAIN DISTRIBUTION PANEL
3000

3000

MPB

MDP
ACU
AIR CONDITION UNIT

1 1 7.5hp PMS
PORTABLE MULTI-PURPOSE SHREDDER M1 MACHINES

2.0hp
HORIZONTAL RIBBON MIXER
HRM

2.0hp ORS
OSCILLATING ROTARY SCREEN-SIFTER
GROUND FLOOR SECOND FLOOR SCREW CONVEYOR WITH HOOPER
A POWER LAYOUT B POWER LAYOUT 2.0hp SCH

A A A A 2.0hp SBH
INCLINED BELT CONVEYOR WITH HOOPER
SCALE 1:100 MTS. SCALE 1:100 MTS.
2 2 2 2

3D RENDERING AND CAD SERVICES


PRC NO. PROJECT TITLE: OWNER: SHEET CONTENTS: REVISIONS: SHEET NO.

___________________________ PTR NO.


DIGITAL ARCHITECTURE LIGHTING LAYOUT

R.A. 9266
PROFESSIONAL ELECTRICAL ENGINEER ISSUED AT ARCHITECTURAL.3D RENDERING.CAD SERVICES
Office Address
PROPOSED TWO STOREY BUILDING MR. ROLF CHUA
POWER LAYOUT
GENERAL NOTES
7 7
Drawings and specifications duly signed, stamped or sealed, as instruments of service, are the CITY OF ILAGAN . ISABELA . PHILIPPINES Contact No. LEGENDS
ISSUED ON

E-1
intellectual properties and documents of the architect, whether the object for which they are
made is executed or not, It shall be unlawful for any person, without the consent of the
email address SUN 0923 701 3521
architect or author of said documents, to duplicate or to make copies of said documents for roycristobal@gmail.com/roycristobal@yahoo.com GLOBE 0917 182 0195
TIN NO. LOCATION: 708 ILAYANG PULO, BARANGAY IBA, SILANG, CAVITE ADDRESS: 708 ILAYANG PULO, BARANGAY IBA, SILANG, CAVITE
use in the repetition of and for other projects or buildings, whether executed partly or in whole.

You might also like