Professional Documents
Culture Documents
TEK - All About TDR
TEK - All About TDR
及
電路模型應用
Agenda
fTDR resolution and accuracy
fDifferential transmission line
fHow to make test coupon
fOther TDR/TDT measurement
Impedance and Signal Integrity Issues
Differential
Transmitter
f Interconnects (paths)
+ + + + + path +
- - - - - -
path path
f Receivers + Rcv
Differential
Receiver
Tx + + path + + Rcv
- - - -
- - - - path - - - -
- - - - - - - -
path
Tx + + path + + Rcv
- - - -
6.25Gb/s at Tx launch into backplane 6.25Gb/s at 17in (43cm) of backplane 6.25Gb/s after 34in (86cm) of backplane
Tx + + path +
- - -
Tx + + path + + Rcv
- - - -
CDR DATA
DATA
CLOCK
Tx + + path + + Rcv
- - - -
Data
voltage
time
Data
time
Pattern Sync
Precision variable delay
voltage
vectors are not drawn since
adjacent samples can jump
from logical 1 to 0 frequently
Mask
test
time
Clock
Impedance
Change
Incident Energy
Transmitted Energy
Reflected Energy
TDR Fundamentals –
Applied Step Signal
f Starting with a transmission line with a characteristic
impedance Z equal to Z0
f A fast rise-time step signal is applied at the transmission line
input point
f The step signal will propagate down the line
Propagating
Step
Step
Source
Transmission Characteristic
Line Impedance Z = Z0
TDR Fundamentals –
Impedance Change
f An impedance change in the transmission line will cause a
change in the amplitude of the propagating step
Impedance
Change Point
Step
Source
Characteristic
Characteristic Impedance Z2 > Z0
Impedance Z1 = Z0
TDR Fundamentals –
Transmitted and Reflected Signals
f The change in impedance causes some of the energy to be
reflected back to the source
f The remainder of the energy will be transmitted
Incident Transmitted
Step Step
Step Z1 = Z0 Z2 > Z0
Source
Reflected
Step
TDR Fundamentals –
Oscilloscope Monitoring
f Use an oscilloscope to monitor the transmission line signal at
the step source input point
f The oscilloscope waveform will show the combined sum of the
incident and reflected propagating signals in proper time
sequence
Oscilloscope
Measurement
Point
Step Z1 = Z0 Z2 > Z0
Source
eSerial: Interconnect itself Characterized using
Time Domain Reflectometry (TDR)
TDR
(80E04)
+ + + + Rcv
- - - -
Time
f TDR on an Equivalent Time scope is used to measure the quality of the serial
data interconncet: A step is generated and returning reflections are sampled
(it’s like radar for serial data cables and boards)
eSerial: Differential TDR is used on differential
interconnects.
TDR
(80E04)
+ + + + Rcv
- - - -
Voltage
Time
f Two TDR sampling channels allow the differential impedance between the
DATA+ and DATA- eSerial paths to be measured.
eSerial: TDR is commonly used in design and
manufacturing test of eSerial Interconnects
Voltage
Time
f TDR can test passive eSerial Interconnect to characterize where poor quality
will exist when Gbit DATA is sent through it.
TDR Overview - Typical System
Incident Step
Sampler
Reflections
50
Step Generator
TDR Overview
Amplitude
+1ρ Open (Z = ∗)
Reflected
0ρ (Z = 50Ω)
Incident
Short (Z = 0)
-1ρ
t0 t1 Time
TDR Overview - Lumped Discontinuities
System Performance Limited by Interconnect
between ICs
Output Input
Driver Receiver
Circuit Board
Package Model Transmission Line Package Model
I
RSOURCE
Z0 = L
c
TDR Overview - Microstrip Discontinuities
Volts or ρ Open
Connector Circuit
Capacitive Inductive
Discontinuity Discontinuity
Incident Step
Bondwire IC
Package
Physical Structure
Circuit Board
Pin
L1 Z0, td L2
Equivalent SPICE Model
C R
TDR Trace
TDR Overview - Reflection Coefficient and
Impedance
Reflected Amplitude Z T - Z0
Rho (ρ) = =
Incident Amplitude Z T + Z0
1 + .2
= 50 1 - .2
= 75Ω −1ρ
200ps/div
TDR Resolution
f No TDR Measurement is Ideal
– Risetime limited on TDR Measurement Device
– Interconnect Limited by Parasitics
Z0 Z1, tD Z0
ρ
tr(system)
2tD
f Resolution Factors
Interconnect Settling Time
– Cable quality
– Connector quality
– Launch quality Rise Time
Foot
Preshoot
TDR Resolution
f Rule of Thumb:
– Two Discontinuities will be Indistinguishable if Separated by less than Half
the System Rise Time
f Cable Losses
– Apparent Z Increase over Time
– From Interconnect or DUT
– Caused mostly by Skin Effect
– Times Involved can be Very Long
Cable Losses
TDT response of 1 meter RG-58
0.8%/div 100%
5 ns/div
TDR Accuracy - Test System
f Multiple Reflections
– Can Appear Anywhere in a Waveform
– Can Look Like Anomaly or Z-shift
– Are Predictable
– Might be Controllable
Z0 = 50Ω Z1 = 90Ω
(Open)
1
1.286
0.286
1.286
0.918
SMA
probe
Multiple reflections
from stub after probe
Interface Transmission Loss
f Effects are Linear
f Can be Deconvolved (Iconnect)
f Impedance Readings can be Corrected
f Can Calibrate Once and Subsequent Measurements Corrected
TDR Accuracy Improvement
IPC - TM - 650 Method
f Eliminates These Errors
– Step / Sampler Offset
– Step Generator Amplitude Error
– Sampler Gain Error (Single Gain Setting)
– Most Aberration Errors
– Long Term Drift / Temperature Effects
– Skin - Effect Loss Errors
– Interface Transmission Loss
TDR Accuracy Improvement - Steps:
f Preliminary Steps
– Preset TDR
– Turn off Rho Cal
– Turn off Baseline Correct
– Hook Up Probe CALIBRATED AIR LINE
PROBE
1
80E04
2
DUT
TDR Accuracy Improvement - Steps:
f Measure Probe Impedance with Air Line
– Disconnect Air Line and Measure Size of Step Incident on Air Line VI,
as Modified by Passing Back to Sampler.
Open
VI
Probe
– Re-connect Air Line and Measure size of Step Reflected from Air Line
VR, as Modified by Passing Back to Sampler.
Open
Probe VR
Air Line
εR
Odd and Even Modes
+ - + +
Odd Mode Even Mode
Model for Symmetric Coupled Lines
Ra
R1 R1
Rb Rb
R2
Pi Tee
Characterizing Symmetric Coupled Lines -
Odd Mode
Odd Mode
Rb Rb R2
Zodd = (Ra/2)|| Rb
Characterizing Symmetric Coupled Lines -
Even Mode
Even Mode
Ra R1 R1
Zeven = R1 + 2R2
TDR Measurements –
Differential TDR Measurement
rho Ch 1
Ch 2
time
rho
Ch 1 - Ch. 2
time
TDR Measurements –
Differential Clock Coupling
f Attempting to measure the two halves of the differential pair
separately can produce misleading results
f Two traces in close proximity tend to read a lower impedance
than their characteristic impedance as a pair
f Proper characterization of the differential impedance of the
transmission line to maintain voltage and timing margins
TDR Measurements –
Differential TDR Measurement
f A differential TDR measurement is performed much like a
single-ended TDR measurement
f Use two TDR sampling head channels with the step generators
set to opposite polarities
TDR Measurements –
Differential TDR Step Timing Skew
f Another important consideration when making differential TDR
measurement is the alignment of the TDR step pulses
f The positive and negative going TDR steps must be adjusted so
there is not any time skew between them at the transmission
line launch point
Agenda
fTDR resolution and accuracy
fDifferential transmission line
fHow to make test coupon
fOther TDR/TDT measurement
Test Coupons
60 D
d Zo = Ln[ ]
V εr d
Vε
D
COAXIAL CABLE
Characterize Impedance(2)
d
60 4H
H Zo = Ln[ ]
V εr d
WIRE-OVER-GROUND
Characterize Impedance(3)
W
T
H Micro-strip-line
87 5.98*H
Zo = Ln( )
V εr +1.41 0.8W +T
Characterize Impedance(4)
T
A
W B
87 5.98*B
Zo = Ln( )
V εr +1.41 0.8W +T
ε r = ε[1−exp(-1.55A/B)]
Embedded Micro-strip or Coated micro-strip
Characterize Impedance(5)
A
W W
T
120 πA
Zo = Ln[ ]
V εr W+T
Side by side
Characterize Impedance(6)
T
377 H
H Zo = Ln[ ]
V εr W
T
Flat Parallel
Characterize Impedance(7)
H
D T Strip-line
H W
60 4D
Zo = Ln[ ]
V εr 0.67 π (0.8W+T)
Characterize Impedance(8)
power
A W
signal
T
B Dual-strip-line or
Asymmetric strip-line
A
80 1.9(2A+T)
Zo = Ln[ ] x [ 1- A
]
V εr (0.8W+T) 4(A+B+T)
Agenda
fTDR resolution and accuracy
fDifferential transmission line
fHow to make test coupon
fOther TDR/TDT measurement
DUT TDR / TDT Measurements
f Cross-Talk
f Moding
f Transmission Line Losses
f Transmission Line Dispersion
Crosstalk
f Generalities:
– Proportional to the Line Length
– Proportional to Rise Time of Driving Signal
– Can be Positive or Negative
(Inductive or Capacitive Coupling)
– Both Forward (Near-end) and Backward (Far-end)
– Non-Characteristic Port Terminations Make it Worse
Crosstalk Measurement Techniques
DUT
+
1
80E04
2 50
50
Serial Data Crosstalk: TDR/TDT is a Tool to
Characterize This Difficult Problem
0.8%/div 100%
5 ns/div
Transmission Line Dispersion
⎡∂ ⎤
s11 = fft ⎢ (TDR _ reflected _ waveform)⎥
⎣ ∂t ⎦
23TDA Systems, Inc. IConnect® Software
f Measure board impedance and propagation delay
– Analyze failures, resolve smaller discontinuities
⇒ SPICE / IBIS
Simulation
(HSpice, PSpice
BSpice)
TDR ⇒
TDS8000
⇒
Field Solver
Analysis
⇒
f MeasureXtractor™
– Automatically convert TDR/T or S-
parameter data into exact frequency
dependent models
– Easily ensure SPICE / IBIS
simulation accuracy f Efficient, easy-to-use and cost-effective!
f Works with TDS/CSA8200 TDR scope
New!
What is IConnect® S-parameters?
The easiest way to perform S-parameter
measurements for digital interconnects
f Differential, mixed mode, single ended
f Compliance testing for PCI-Xpress, Serial ATA,
Infiniband, Gigabit Ethernet and other standards
f Easily de-embed fixture effects
f Basic calibration capability
Impedance Accuracy: IConnect Z-line
Multiple reflections in
TDR waveform
Accurate impedance
profile in IConnect®
Impedance Accuracy : IConnect Z-line
Cursors placed
Z, td read
L, C read
Impedance Accuracy : IConnect Z-line
Impedance profile
in IConnect®:
Exact failure location,
improved resolution
Impedance Accuracy : IConnect Z-line
Z-line Applications and Benefits
f What does Z-line do?
– Corrects for multiple reflections inside the DUT, which produce
impedance inaccuracies
f Benefits:
– Avoid accuracy and disputes with vendors/customers through improved
accuracy and repeatability for PCB impedance measurements
f Both in manufacturing and in PCB technology development
– Locate package, board and connector failures faster through improved
resolution
– Get quick access to direct Z, td, L and C readouts from the corrected
impedance profile
Package and Die Capacitance
f Benefits
– Efficient and quick measurement of input die and package
capacitance
f A standard method in the semiconductor industry
f Measurements of the Cdie in powered-up condition possible
Appnote: “Measurement of Input … Die Capacitance … Using TDR”
– Method is also efficiently applied to…
f Small-size package, connector and socket modeling
f Measuring inductance of a via on the board
TDT and IConnect Eye Diagram
Eye Diagram In IConnect
Correlation
Data courtesy
FCI Electronics
TDT and IConnect Eye Diagram
f Benefits:
– Efficient compliance testing for cable assemblies: (SATA, PCI Xpress,
Infiniband, Gigabit Ethernet) - save time and money!
f No pattern generator (PG) required (at 10 Gbit/sec PG can cost >>$100k
vs. <$20k for IConnect!)
f Save time: an eye is generated 100x faster than with PG!
f Leverage your TDR oscilloscope investment and save test space
– Quick isolation of system level problem – rapidly determine whether
system performance is poor due to transmitter or to interconnect link
– Quick evaluation of maximum performance for a legacy backplane
Frequency Dependent S-parameters
New!
IConnect® S-parameters
The easiest way to perform S-parameter
measurements for digital interconnects
f Differential, mixed mode, single ended
f Compliance testing for PCI-Xpress, Serial ATA,
Infiniband, Gigabit Ethernet and other standards
f Easily de-embed fixture effects
f Basic calibration capability
Frequency Dependent S-parameters
IConnect S-parameter Uniqueness
f How do you measure differential return loss of a DUT when it is
soldered on the board? – with IConnect using short reference!
– Short the two pins of the DUT package with an Xacto knife – and you have
a short reference to compute S-parameters
– You can not do this otherwise!
-5
time -25
-30
GHz -10
VNA
-40
4022
-50
-60
0 10 20 30 40 50 60
frequency (GHz)
Measurement-Based Modeling
Measurement Based Approach
z Extracted interconnect,
instrument source models
SPICE
z Direct link to simulators
z Automatic comparison of
simulation and measurement
in IConnect waveform viewer
Measurement-Based Modeling
Methodology: Gbit Ethernet Example