Model S1F Non-Metallic Design Level 3: Service & Operating Manual

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 36

SERVICE & OPERATING MANUAL

Model S1F Non-Metallic Design Level 3 U.S. Patent #


400,210
CE 5,996,627
6,241,487
Table of Contents
Engineering Data and Temperature Limitations ............................................................................ 1 Air Distribution Valve Servicing ..................................................................................................... 19
Explanation of Pump Nomenclature .............................................................................................. 2 Air Distribution Valve with Stroke Indicator Options ..................................................................... 20
Performance Curve, Model S1F Non-Metallic Design Level 3 ...................................................... 3 Air Distribution Valve with Stroke Indicator Parts List .................................................................. 20
Dimensions: S1F Non-Metallic ........................................................................................................ 4 Air Distribution Valve with Stroke Indicator Servicing ................................................................... 21
Metric Dimensions: S1F Non-Metallic ............................................................................................. 5 Solenoid Shifted Air Valve Drawing .............................................................................................. 22
Dimensions: S1F Spill Prevention .................................................................................................. 6 Solenoid Shifted Air Valve List ..................................................................................................... 22
Metric Dimensions: S1F Spill Prevention ........................................................................................ 7 Solenoid Shifted Air Distibution Valve Option .............................................................................. 23
Principle of Pump Operation ........................................................................................................... 8 Pilot Valve Assembly Drawing ....................................................................................................... 24
Installation and Start-up ................................................................................................................. 8 Pilot Valve Assembly Parts List ..................................................................................................... 24
Air Supply ........................................................................................................................................ 8 Pilot Valve Servicing ...................................................................................................................... 25
Air Valve Lubrication ....................................................................................................................... 8 Diaphragm Service Drawing, Non-Overlay ................................................................................... 26
Air Line Moisture .............................................................................................................................. 8 Diaphragm Service Drawing, with Overlay .................................................................................... 26
Air Inlet and Priming ........................................................................................................................ 8 Diaphragm Servicing ..................................................................................................................... 27
Between Uses ................................................................................................................................. 8 Overlay Diaphragm Service .......................................................................................................... 27
Installation Guide ............................................................................................................................ 9 Pumping Hazardous Liquids ......................................................................................................... 28
Important Safety Information ........................................................................................................ 10 Converting the pump for piping the exhaust air .......................................................................... 28
Material Codes .............................................................................................................................. 10 Exhaust Conversion Drawing ........................................................................................................ 28
Troubleshooting ............................................................................................................................. 11 Converted Exhaust Illustration ..................................................................................................... 28
Warranty ........................................................................................................................................ 11 Modular Check Valve Servicing .................................................................................................... 29
Composite Repair Parts Drawing .................................................................................................. 12 Modular Check Valve Drawing ...................................................................................................... 29
Overlay Option Drawing ................................................................................................................ 12 Dual Port Option Drawing ............................................................................................................. 30
Composite Repair Parts List ......................................................................................................... 13 Dual Porting Options ..................................................................................................................... 31
RuppGUARD™ Spill Prevention Option for Virgin PTFE Equipped Pumps ............................... 14 Dual porting of both suction and discharge ends of the pump .................................................. 31
RuppGUARD™ Spill Prevention Repair Parts List ....................................................................... 14 Single porting of the suction and dual porting of the pump discharge ...................................... 31
RuppGUARD™ Spill Prevention Concept .................................................................................... 15 Dual porting of the suction and single porting of the pump discharge ....................................... 31
RuppGUARD™ Spill Prevention Option Diaphragm Servicing .................................................... 15 RuppTech® Leak Detection Options Drawing ............................................................................. 32
Filling RuppGUARD™ Chambers with Liquid ............................................................................... 15 RuppTech® Electronic Leak Detector Installation ....................................................................... 32
RuppGUARD™ Spill Prevention Option for TPE Equipped Pumps ............................................ 16 RuppTech® Mechanical Leak Detector Installation ..................................................................... 32
RuppGUARD™ Spill Prevention Repair Parts List ....................................................................... 16 RuppTech® Pulse Output Kit Drawing ......................................................................................... 33
RuppGUARD™ Spill Prevention Concept with TPE Diaphragms ............................................... 17 RuppTech® Pulse Output Kit Option ........................................................................................... 33
RuppGUARD™ Spill Prevention Option with TPE Diaphragm .................................................... 17 Exhaust Port or Auxiliary Muffler Setup ....................................................................................... 33
Air Distribution Valve Assembly Drawing ...................................................................................... 18 Integral Muffler Setup ................................................................................................................... 33
Main Air Valve Assembly Parts List ............................................................................................... 18 Optional Muffler configurations, Drawing ..................................................................................... 34

Warren Rupp, Inc. • A Unit of IDEX Corporation • P.O. Box 1568, Mansfield, Ohio 44901-1568 USA • Tel: (419) 524-8388 • Fax (419) 522- 7867 • www.warrenrupp.com
520-199-000 7/02
Quality System S1F Non-Metallic
Design Level 3
ISO9001 Certified U.S. Patent #
5,996,627;
400,210;
Ball Valve
Environmental
Management System 6,241,487
ISO14001 Certified Other U.S. Patents
Applied for
Air-Powered
Double-Diaphragm Pump
Air Exhaust Side View Air Inlet Side View
CE ENGINEERING, PERFORMANCE
& CONSTRUCTION DATA

INTAKE/DISCHARGE PIPE SIZE CAPACITY AIR VALVE SOLIDS-HANDLING HEADS UP TO DISPLACEMENT/STROKE


1" ANSI Flange or 0 to 45 gallons per minute No-lube, no-stall Up to .25 in. (6mm) 100 psi or 231 ft. of water .17 gallon / .64 liter
PN10 25mm DIN Flange (0 to 170 liters per minute) design (7 bar or 70 meters)

CAUTION! Operating temperature limitations are as follows:

Operating Temperatures
Materials Maximum* Minimum* Optimum**
Santoprene® Injection molded thermoplastic elastomer with no fabric layer. Long mechanical flex 212°F -10°F 50° to 212°F
life. Excellent abrasion resistance. 100°C -23°C 10°C to 100°C
Virgin PTFE Chemically inert, virtually impervious. Very few chemicals are known to react chemically
with PTFE: molten alkali metals, turbulent liquid or gaseous fluorine and a few fluoro-chemicals such as 212°F -35°F 50°F to 212°F
chlorine trifluoride or oxygen difluoride which readily liberate free fluorine at elevated temperatures. 100°C -37°C 10°C to 100°C
PVDF 200°F -10°F
-93°C -13°C
Polypropylene 150°F -40°F
65°C 5°C

For specific applications, always consult “Chemical Resistance Chart” Technical Bulletin *Definite reduction in service life.
**Minimal reduction in service life at ends of range.

SandPIPER II® pumps are designed to be powered only by compressed air.

®Santoprene is a registered tradename of Monsanto Corporation


®SandPIPER II and Warren Rupp are registered tradenames of Warren Rupp, Inc.

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 1


Explanation of Pump Nomenclature
S1F Non-Metallic · Design Level 3 · Ball Valve
Check Diaphragm/ Check Non-Wetted Shipping
Model Pump Pump Valve Design Wetted Check Valve Valve Material Porting Pump Pump Kit Weight
Brand Size Type Level Material Materials Seat Options Options Style Options Options lbs. (kg)
S1FB3P1PPUS000. S 1F B 3 P 1 P P U S 0 00. 42 (19)
S1FB3P2PPUS000. S 1F B 3 P 2 P P U S 0 00. 42 (19)
S1FB3K1KPUS000. S 1F B 3 K 1 K P U S 0 00. 54 (24)
S1FB3K2KPUS000. S 1F B 3 K 2 K P U S 0 00. 54 (24)
S1FB3P3PPUV000. S 1F B 3 P 3 P P U V 0 00. 48 (22)
S1FB3K3KPUV000. S 1F B 3 K 3 K P U V 0 00. 64 (29)
S1FB3P4PPUV000. S 1F B 3 P 4 P P U V 0 00. 48 (22)
S1FB3K4KPUV000. S 1F B 3 K 4 K P U V 0 00. 64 (29)

Pump Brand Check Valve Seat Pump Style Kit Options


S= SandPIPER II® K= PVDF D= RuppGUARD™ with Electronic 00.= None
P= Polypropylene Leak Detection (110V) P0.= 0-30VDC Pulse Output Kit
Pump Size
1F= 1" Full Flow Non-Wetted Material Options E= RuppGUARD™ with Electronic P1.= Intrinsically-Safe 10-30VDC
P= Polypropylene Leak Detection (220V) Pulse Output Kit
Check Valve Type M= RuppGUARD™ with Mechanical P2.= 110/120 or 220/240VAC
X= Unpainted Aluminum
B= Ball Leak Detection Pulse Output Kit
1= 40% Glass Filled Polypropylene
Design Level with PTFE hardware S= Standard P3.= Intrinsically-Safe 110/120VAC
3= Design Level 3 V= RuppGUARD™ with Visual Pulse Output Kit
Porting Options Leak Detection P4.= Intrinsically-Safe 220/240VAC
Wetted Material U= Universal (Fits ANSI and DIN)
Pump Options Pulse Output Kit
K= PVDF 7= Dual Porting (ANSI)
0= None E0.= Solenoid Kit with 24VDC Coil
P= Polypropylene 8= Top Dual Porting (ANSI)
1= Sound Dampening Muffler E1.= Solenoid Kit with 24VDC
Diaphragm Check Valve 9= Bottom Dual Porting (ANSI) Explosion-Proof Coil
Materials 2= Mesh Muffler
3= High temperature Air Valve E2.= Solenoid Kit with 24VAC/
1= Santoprene/Santoprene 12VDC Coil
2= PTFESantoprene Backup/PTFE w/Encapsulated Muffler
4= High temperature Air Valve E3.= Solenoid Kit with 24VAC
3= PTFE Pumping, PTFE-Santoprene
w/Sound Dampening Muffler 12VDC Explosion-Proof Coil
Backup Driver/PTFE
5= High temperature Air E4.= Solenoid Kit with 110VAC Coil
4= Santoprene Pumping/Santoprene
Valve w/Mesh Muffler E5.= Solenoid Kit with 110VAC
Explosion-Proof Coil
E6.= Solenoid Kit with 220VAC Coil
E7.= Solenoid Kit with 220VAC
Explosion-Proof Coil
SP.= Stroke Indicator Pins

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 2


Performance Curve, Model S1F Non-Metallic
Design Level 3
BAR
PSI
5 (8.5)
15 (25.5)
10 (17)
7 100 1
00
PSI
(6.8 20 (34)
90 Bar
) 25 (42.5)
6
80 30 (51)
80 P
S I (5.
5 44 B
70 ar)
35 (59.5)
60
4 60 P 40 (68)
Head

S I (4.0
8 Ba

METERS
r)

NPSHR
50
45 (76.5)

FEET
3
40
40 PS
I (2.72
Bar)
2 30 30 9.7
25 7.6
20 20 6
20 PS
1 I (1.36 15 4.5
Bar) A
10 ir Inlet 10 3
Pressu
re
5 1.5
0 0
0 5 10 15 20 25 30 35 40 45 50 55
U.S. Gallons per minute

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200
Liters per minute

Capacity

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 3


Dimensions: S1F Non-Metallic
Dimensions in Inches
Dimensional tolerance: ±1/8"

DIMENSION A B
Standard Pump 5 5/8" 10 1/4"
Pulse Output Kit 7 3/8" 12"
Mesh Muffler 8 9/16" 11 5/32"
Sound Dampening Muffler 8 9/16" 11 5/32"

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 4


Metric Dimensions: S1F Non-Metallic
Dimensions in Millimeters
Dimensional tolerance: ±3mm

DIMENSION A B
Standard Pump 143mm 260mm
Pulse Output Kit 187mm 305mm
Mesh Muffler 167mm 283mm
Sound Dampening Muffler 167mm 283mm

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 5


Dimensions: S1F Non-Metallic
with RuppGUARD™ Spill Prevention
Dimensions in Inches
Dimensional tolerance: ±1/8"

DIMENSION A B
Standard Pump 5 5/8" 10 1/4"
Pulse Output Kit 7 3/8" 12"
Mesh Muffler 8 9/16" 11 1/8"
Sound Dampening Muffler 8 9/16" 11 1/8"

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 6


Metric Dimensions: S1F Non-Metallic
with RuppGUARD™ Spill Prevention
Dimensions in Millimeters
Dimensional tolerance: ±3mm

DIMENSION A B
Standard Pump 143mm 260mm
Pulse Output Kit 187mm 305mm
Mesh Muffler 167mm 283mm
Sound Dampening Muffler 167mm 283mm

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 7


PRINCIPLE OF PUMP OPERATION shifts to the opposite end of the valve supply line is solid piping, use a short to supplement the user’s air drying
This ball type check valve pump is body, the pressure to the chambers is length of flexible hose not less than ½" equipment. This device removes water
powered by compressed air and is a 1:1 reversed. The air distribution valve spool (13mm) in diameter between the pump from the compressed air supply and
ratio design. The inner side of one is moved by a internal pilot valve which and the piping to reduce strain to the alleviates the icing or freezing problems.
diaphragm chamber is alternately alternately pressurizes one end of the piping. The weight of the air supply line,
air distribution valve spool while regulators and filters must be supported AIR INLET AND PRIMING
pressurized while simultaneously
exhausting the other end. The pilot valve by some means other than the air inlet To start the pump, open the air valve
exhausting the other inner chamber. This
is shifted at each end of the diaphragm cap. Failure to provide support for the approximately ½ to ¾ turn. After the
causes the diaphragms, which are
stroke when a actuator plunger is piping may result in damage to the pump primes, the air valve can be
connected by a common rod secured
contacted by the diaphragm plate. This pump. A pressure regulating valve opened to increase air flow as desired.
by plates to the centers of the
actuator plunger then pushes the end of should be installed to insure air supply If opening the valve increases cycling
diaphragms, to move in a reciprocating
the pilot valve spool into position to pressure does not exceed recommended rate, but does not increase the rate of
action. (As one diaphragm performs the
activate the air distribution valve. limits. flow, cavitation has occurred. The valve
discharge stroke the other diaphragm
The chambers are connected with should be closed slightly to obtain the
is pulled to perform the suction stroke
manifolds with a suction and discharge AIR VALVE LUBRICATION most efficient air flow to pump flow ratio.
in the opposite chamber.) Air pressure
check valve for each chamber, The air distribution valve and the pilot
is applied over the entire inner surface BETWEEN USES
maintaining flow in one direction through valve are designed to operate WITHOUT
of the diaphragm while liquid is When the pump is used for materials
the pump. lubrication. This is the preferred mode
discharged from the opposite side of the that tend to settle out or solidify when
of operation. There may be instances of
diaphragm. The diaphragm operates in not in motion, the pump should be flushed
INSTALLATION AND START-UP personal preference or poor quality air
a balanced condition during the after each use to prevent damage.
Locate the pump as close to the supplies when lubrication of the
discharge stroke which allows the pump (Product remaining in the pump between
product being pumped as possible. Keep compressed air supply is required. The
to be operated at discharge heads over uses could dry out or settle out. This could
the suction line length and number of pump air system will operate with
200 feet (61 meters) of water. cause problems with the diaphragms and
fittings to a minimum. Do not reduce the properly lubricated compressed air
For maximum diaphragm life, keep check valves at restart.) In freezing
suction line diameter. supply. Proper lubrication requires the
the pump as close to the liquid being temperatures the pump must be
For installations of rigid piping, short use of an air line lubricator (available from
pumped as possible. Positive suction completely drained between uses in all
sections of flexible hose should be Warren Rupp) set to deliver one drop of
head in excess of 10 feet of liquid (3.048 cases.
installed between the pump and the SAE 10 non-detergent oil for every 20
meters) may require a back pressure
piping. The flexible hose reduces SCFM (9.4 liters/sec.) of air the pump
regulating device to maximize
vibration and strain to the pumping consumes at the point of operation.
diaphragm life.
system. A surge suppressor is Consult the pump’s published
Alternate pressurizing and
recommended to fur ther reduce Performance Curve to determine this.
exhausting of the diaphragm chamber
pulsation in flow.
is performed by an externally mounted, AIR LINE MOISTURE
pilot operated, four way spool type air AIR SUPPLY Water in the compressed air supply
distribution valve. When the spool shifts Air supply pressure cannot exceed can create problems such as icing or
to one end of the valve body, inlet 100 psi (7 bar). Connect the pump air freezing of the exhaust air, causing the
pressure is applied to one diaphragm inlet to an air supply of sufficient pump to cycle erratically or stop
chamber and the other diaphragm capacity and pressure required for operating. Water in the air supply can be
chamber exhausts. When the spool desired performance. When the air reduced by using a point-of-use air dryer

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 8


INSTALLATION GUIDE
Top Discharge Ball Valve Unit

1
Available from
Warren Rupp

1 DA05 Surge Suppressor


2 020-049-000 Filter/Regulator
3 020-049-001 Lubricator
4 Air Dryer

CAUTION
The air exhaust should be
piped to an area for safe
disposition of the product
being pumped, in the event
of a diaphragm failure.

4
3
2

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 9


Material Codes
Important Safety Information The Last 3 Digits of Part Number
000 ......... Assembly, sub-assembly; and some purchased items 370 ......... Butyl Rubber. Color coded: BROWN
010 ......... Cast Iron 371 ........ Philthane (Tuftane)
012 ......... Powered Metal 374 ......... Carboxylated Nytrile
015 ......... Ductile Iron 375 ........ Fluorinated Nitrile
IMPORTANT WARNING 020 ......... Ferritic Malleable Iron 378 ........ High Density Polypropylene
025 ........ Music Wire 405 ........ Cellulose Fibre
Read these safety warnings This pump is pressurized 080 ........ Carbon Steel, AISI B-1112 408 ........ Cork and Neoprene
and instructions in this internally with air pressure 100 ........ Alloy 20 425 ........ Compressed Fibre
manual completely, before 110 ........ Alloy Type 316 Stainless Steel 426 ........ Blue Gard
during operation. Always 111 ........ Alloy Type 316 Stainless Steel (Electro Polished) 440 ........ Vegetable Fibre
installation and start-up make certain that all bolting 112 ........ Alloy “C” (Hastelloy equivalent) 465 ........ Fibre
of the pump. It is the is in good condition and that 113 ......... Alloy Type 316 Stainless Steel (Hand Polished) 500 ........ Delrin 500
responsibility of the purchaser to retain this all of the correct bolting is reinstalled during 114 ......... 303 Stainless Steel 501 ........ Delrin 570
manual for reference. Failure to comply with assembly. 115 ......... 302/304 Stainless Steel 502 ........ Conductive Acetal, ESD-800
the recommendations stated in this manual will 117 ......... 440-C Stainless Steel (Martensitic) 503 ........ Conductive Acetal, Glass-Filled
damage the pump, and void factory warranty. 120 ......... 416 Stainless Steel (Wrought Martensitic) 505 ........ Acrylic Resin Plastic
123 ......... 410 Stainless Steel (Wrought Martensitic) 506 ........ Delrin 150
148 ........ Hardcoat Anodized Aluminum 520 ........ Injection Molded PVDF Natural color
149 ........ 2024-T4 Aluminum 540 ........ Nylon
150 ........ 6061-T6 Aluminum 541 ........ Nylon
WARNING 151 ........ 6063-T6 Aluminum 542 ........ Nylon
CAUTION 152 ........ 2024-T4 Aluminum (2023-T351) 544 ........ Nylon Injection Molded
When used for toxic or 154 ........ Almag 35 Aluminum 550 ........ Polyethylene
aggressive fluids, the pump 155 ........ 356-T6 Aluminum 551 ......... Glass Filled Polypropylene
Before pump operation, 156 ........ 356-T6 Aluminum 552 ......... Unfilled Polypropylene
inspect all gasketed should always be flushed 553 ......... Unfilled Polypropylene
157 ........ Die Cast Aluminum Alloy #380
fasteners for looseness clean prior to disassembly. 158 ........ Aluminum Alloy SR-319 555 ......... Polyvinyl Chloride
caused by gasket creep. 159 ......... Anodized Aluminum 556 ......... Black Vinyl
Re-torque loose fasteners 162 ......... Brass, Yellow, Screw Machine Stock 558 ......... Glass Filled Conductive HDPE
165 ........ Cast Bronze, 85-5-5-5 570 ......... Rulon II
to prevent leakage. Follow recommended 580 ......... Ryton
166 ........ Bronze, SAE 660
torques stated in this manual. 170 ........ Bronze, Bearing Type, Oil Impregnated 590 ......... Valox
175 ........ Die Cast Zinc 591 ......... Nylatron G-S
WARNING 180 ........ Copper Alloy
305 ........ Carbon Steel, Gray Epoxy Coated
592 ........ Nylatron NSB
600 ......... Virgin PTFE
306 ......... Carbon Steel, Black PTFE Coated 601 ......... PTFE (Bronze and moly filled)
Before doing any 307 ........ Aluminum, Gray Epoxy Coated 602 ......... Filled PTFE
WARNING maintenance on the pump, be 308 ......... Stainless Steel, Black PTFE Coated 603 ........ Blue Gylon
certain all pressure is 309 ......... Aluminum, Black PTFE Coated 604 ......... Virgin PTFE
Before maintenance or completely vented from the 310 ......... Kynar® Coated 607 ........ Envelon
repair, shut off the com- pump, suction, discharge, 330 ......... Zinc Plated Steel 606 ......... Injected molded PFA
pressed air line, bleed the piping, and all other openings and connections. 331 ........ Chrome Plated Steel 610 ......... Encapsulated Silicon
pressure, and disconnect 332 ........ Aluminum, Electroless Nickel Plated 611 ......... Encapsulated Viton
Be certain the air supply is locked out or made 333 ........ Carbon Steel, Electroless Nickel Plated 632 ......... Neoprene/Hytrel
the air line from the pump. non-operational, so that it cannot be started while 633 ........ Viton/PTFE
335 ........ Galvanized Steel
The discharge line may be pressurized and work is being done on the pump. Be certain that 336 ........ Zinc Plated Yellow Brass 634 ........ EPDM/PTFE
must be bled of its pressure. approved eye protection and protective clothing 337 ........ Silver Plated Steel 637 ......... PTFE, Viton
are worn all times in the vicinity of the pump. 340 ........ Nickel Plated 638 ......... PTFE, Hytrel
Failure to follow these recommendations may 342 ........ Filled Nylon 639 ......... Buna-N
353 ......... Geolast; Color: Black 643 ......... Santoprene®/EPDM
result in serious injury or death. 354 ........ Injection Molded #203-40 Santoprene - Duro 40D 644 ......... Santoprene®
+/-5; Color: RED
Delrin, Viton and Hytrel are registered tradenames of
WARNING 355 ........ Thermal Plastic
356 ......... Hytrel®
E.I. DuPont.
Gylon is a registered tradename of Garlock, Inc.
In the event of diaphragm 357 ........ Injection Molded Polyurethane
Nylatron is a registered tradename of Polymer Corp.
358 ........ Rupplon (Urethane Rubber). Color coded:
rupture, pumped material Santoprene is a registered tradename of Monsanto Corp.
may enter the air end of the WARNING PURPLE (Some Applications) (Compression Mold)
359 ........ Urethane Rubber Kynar® is a registered tradename of ATOFINA Chemicals,Inc.
pump, and be discharged 360 ........ Buna-N Rubber. Color coded: RED Rulon II is a registered tradename of Dixion Industries Corp.
Airborne particles and loud
into the atmosphere. If 361 ........ Buna-N Hastelloy-C is a registered tradename of Cabot Corp.
noise hazards. 363 ........ Viton (Flurorel). Color coded: YELLOW
pumping a product which is hazardous or toxic, Ryton is a registered tradename of Phillips Chemical Co.
the air exhaust must be piped to an appropriate Wear ear and eye protection. 364 ........ E.P.D.M. Rubber. Color coded: BLUE Valox is a registered tradename of General Electric Co.
365 ........ Neoprene Rubber. Color coded: GREEN
area for safe disposition. Warren Rupp, Rupplon, SandPIPER, SandPIPER II, PortaPump,
366 ........ Food Grade Nitrile Tranquilizer, RuppGUARD, RuppTech and SludgeMaster are
368 ......... Food Grade EPDM tradenames of Warren Rupp, Inc.

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 10


TROUBLESHOOTING What to Check: Undersized suction line. What to Check: Pumped fluid in air What to Check: Blocked pumping
Possible Symptoms: Corrective Action: Meet or exceed exhaust muffler. chamber.
• Pump will not cycle. pump connection recommendations Corrective Action: Disassemble pump Corrective Action: Disassemble and
• Pump cycles, but produces no flow. shown on the DIMENSIONAL chambers. Inspect for diaphragm rupture inspect the wetted chambers of the
DRAWING. or loose diaphragm plate assembly. Refer pump. Remove or flush any obstructions.
• Pump cycles, but flow rate is to the Diaphragm Replacement section Refer to the pump SERVICE MANUAL
unsatisfactory. What to Check: Restricted or undersized of your pump SERVICE MANUAL. for disassembly instructions.
• Pump cycle seems unbalanced. air line.
• Pump cycle seems to produce Corrective Action: Install a larger air line What to Check: Suction side air leakage What to Check: Entrained air or vapor
excessive vibration. and connection. Refer to air inlet or air in product. lock in one or both pumping chambers.
recommendations shown in your pump’s Corrective Action: Visually inspect all Corrective Action: Purge chambers
What to Check: Excessive suction lift SERVICE MANUAL. suction side gaskets and pipe through tapped chamber vent plugs.
in system. connections. PURGING THE CHAMBERS OF AIR
Corrective Action: For lifts exceeding What to Check: Check ESADS, the CAN BE DANGEROUS! Contact the
20 feet (6 meters), filling the pumping Externally Serviceable Air Distribution What to Check: Obstructed check Warren Rupp Technical Services
chambers with liquid will prime the pump System of the pump. valve. Department before performing this
in most cases. Corrective Action: Disassemble and Corrective Action: Disassemble the wet procedure. A model with top-ported
inspect the main air distribution valve, end of the pump and manually dislodge discharge will reduce or eliminate
What to Check: Excessive flooded pilot valve and pilot valve actuators. obstruction in the check valve pocket. problems with entrained air.
suction in system. Refer to the parts drawing and air valve Refer to the Check Valve section of the If your pump continues to perform
Corrective Action: For flooded section of the SERVICE MANUAL. pump SERVICE MANUAL for below your expectations, contact your
conditions exceeding 10 feet (3 meters) Check for clogged discharge or closed disassembly instructions. local Warren Rupp Distributor or factory
of liquid, install a back pressure device. valve before reassembly. Technical Services Group for a service
What to Check: Worn or misaligned evaluation.
What to Check: System head exceeds What to Check: Rigid pipe connections check valve or check valve seat.
air supply pressure. to pump. Corrective Action: Inspect check valves Warranty
Corrective Action: Increase the inlet air Corrective Action: Install flexible and seats for wear and proper seating. Refer to the enclosed Warren Rupp
pressure to the pump. Most diaphragm connectors and a surge suppressor. Replace if necessary. Refer to Check Warranty Certificate.
pumps are designed for 1:1 pressure Valve section of the pump SERVICE
ratio at zero flow. What to Check: Blocked air exhaust MANUAL for disassembly instructions.
muffler.
What to Check: Air supply pressure or Corrective Action: Remove muffler What to Check: Blocked suction line.
volume exceeds system head. screen, clean or de-ice and reinstall. Corrective Action: Remove or flush
Corrective Action: Decrease inlet air Refer to the Air Exhaust section of your obstruction. Check and clear all suction
pressure and volume to the pump pump SERVICE MANUAL. screens and strainers.
as calculated on the published
PERFORMANCE CURVE. Pump is What to Check: Blocked discharge line.
cavitating the fluid by fast cycling. Corrective Action: Check for obstruction
or closed discharge line valves.

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 11


Composite Repair Parts Drawing
AVAILABLE SERVICE AND CONVERSION KITS
476-217-000 AIR END KIT (For Polypropylene Center Section)
Seals, O-rings, Gaskets, Retaining RIngs, Air Valve
Sleeve & Spool Set and Pilot Valve Assembly
476-169-558 AIR END KIT (For Aluminum Center Section)
Seals, O-rings, Gaskets, Retaining RIngs, Air Valve
Sleeve & Spool Set and Pilot Valve Assembly
476-218-000 AIR END KIT (Stroke Indicator Option, For
Polypropylene Center Section)
Seals, O-rings, Gaskets, Retaining Rings, Air Valve,
Sleeve & Spool Set and Pilot Valve Assemlby
476-170-558 AIR END KIT (Stroke Indicator Option, For
Aluminum Center Section)
Seals, O-rings, Gaskets, Retaining Rings, Air Valve,
Sleeve & Spool Set and Pilot Valve Assemlby
476-197-354 WETTED END KIT
Santoprene Diaphragms, Santoprene Balls and
PTFE Seals
476-197-654 WETTED END KIT
Santoprene Diaphragms, PTFE Overlay
Diaphragms, TFE Balls and TFE Seals
476-198-655 WETTED END KIT
(For Polypropylene RuppGUARD™)
Santoprene Diaphragms, PTFE Overlay Diaphragms,
PTFE Pumping Diaphragms, PTFE Balls and PTFE Seals
476-198-354 WETTED END KIT
(For Polypropylene RuppGUARD™)
Santoprene Diaphragms, Santoprene Pumping
Diaphragms, Santoprene Ckeck Balls and PTFE Seals

HARDWARE KITS
RuppTech® PULSE OUTPUT KITS
(For Use With 530-010-000 Mufflers, or Piped Exhaust)
475-198-001 DC Kit Overlay Option
475-198-002 DC Intrinsically Safe Kit
475-198-003 110 / 120 VAC or 220 / 240 VAC Kit
475-198-004 110 / 120 VAC Intrinsically Safe Kit
475-198-005 220 / 240 VAC Intrinsically Safe Kit
(For Use With Encapsulated 530-028-550 Muffler)
475-198-006 DC Kit
475-198-007 DC Intrinsically Safe Kit
475-198-008 110 / 120 VAC or 220 / 240 VAC Kit
475-198-009 110 / 120 VAC Intrinsically Safe Kit
475-198-010 220 / 240 VAC Intrinsically Safe Kit
RuppTech® ELECTRONIC LEAK DETECTOR KITS
032-037-000 110 VAC / 220 VAC
032-045-000 12 - 32 VDC

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 12


Composite Repair Parts List
Item Part Number Description Qty Item Part Number Description Qty
1 031-155-000 Air Valve Assembly 1 18 286-108-600 Diaphragm, Overlay 2
031-155-002 Air Valve Assembly w/ PTFE Coated Hardware 1 19 312-104-520 Elbow 2
031-156-000 Air Valve Assembly (No Encapsulated Muffler) 1 312-104-552 Elbow 2
031-156-002 Air Valve Assembly (No Muffler / PTFE Hardware) 1 20 312-113-520 Elbow, Suction 2
031-157-000 Air Valve Assembly (With Stroke Indicator Option) 1 312-113-552 Elbow, Suction 2
031-158-000 Air Valve Assembly (No Muffler w/ Stroke Indicator) 1 21 360-093-360 Gasket, Air Valve 1
2 050-042-354 Ball, Check 4 22 360-103-360 Gasket, Pilot Valve 1
050-042-600 Ball, Check 4 23 360-104-360 Gasket, Air Inlet 1
3 070-006-170 Bushing (With 114-024-307/309) 2 24 360-107-360 Gasket, Inner Chamber (With 114-024-551) 2
4 095-096-558 Pilot Valve Assembly 1 360-105-360 Gasket, Inner Chamber (With 114-024-307/309) 2
5 114-024-551 Intermediate Assembly 1 25 518-179-520 Manifold 2
114-024-307 Intermediate Assembly 1 518-179-552 Manifold 2
114-024-309 Intermediate Assembly 1 26 545-005-115 Nut, Hex 3/8 - 16 32
6 132-035-360 Bumper, Diaphragm 2 545-005-308 Nut, Hex 3/8 - 16 32
7 135-034-506 Bushing, Plunger 2 27 545-008-115 Nut, Hex 1/2 - 13 16
8 165-125-551 Cap, Air Inlet 1 545-008-308 Nut, Hex 1/2 - 13 16
165-125-307 Cap, Air Inlet 1 28 560-001-360 O-ring 2
165-125-309 Cap, Air Inlet 1 29 612-200-157 Inner Diaphragm Plate 2
9 170-020-115 Capscrew, Hex HD 3/8 - 16 x 2.00 16 612-200-082 Inner Diaphragm Plate 2
170-020-308 Capscrew, Hex HD 3/8 - 16 x 2.00 16 30 612-204-520 Outer Diaphragm Plate 2
10 170-030-115 Capscrew, Hex HD 1/2 - 13 x 2.00 16 612-204-552 Outer Diaphragm Plate 2
170-030-308 Capscrew, Hex HD 1/2 - 13 x 2.00 16 31 620-020-115 Plunger, Actuator 2
11 170-052-115 Capscrew, Hex HD 3/8 - 16 x 2.25 16 32 670-048-520 Retainer, Ball 4
170-052-308 Capscrew, Hex HD 3/8 - 16 x 2.25 16 670-048-552 Retainer, Ball 4
12 170-069-115 Capscrew, Hex HD 5/16 - 18 x 1.75 4 33 675-042-115 Ring, Retainer 2
170-069-308 Capscrew, Hex HD 5/16 - 18 x 1.75 4 34 685-058-120 Rod, Diaphragm 1
13 171-053-115 Capscrew, Soc HD 3/8 - 16 x 2.50 4 35 720-004-360 Seal, Diaphragm Rod 2
14 171-015-115 Capscrew, Soc HD 3/8 - 16 x .88 8 36 720-044-600 Seal, Manifold Spacer 4
171-015-308 Capscrew, Soc HD 3/8 - 16 x .88 8 37 720-047-600 Seal, Check Valve 8
171-059-115 Capscrew, Soc HD 7/16 - 14 x 1.25 8 38 722-079-520 Seat, Check Valve 4
(With 114-024-307/309) 722-079-552 Seat, Check Valve 4
171-059-308 Capscrew, Soc HD 7/16 - 14 x 1.25 8 39 901-009-115 Washer, Flat 5/16" 64
(With 114-024-307/309) 901-009-308 Washer, Flat 5/16" 64
15 196-157-520 Chamber, Outer 2 40 901-038-115 Washer, Flat 5/16" 4
196-157-552 Chamber, Outer 2 901-038-308 Washer, Flat 5/16" 4
16 196-177-551 Chamber, Inner 2 41 901-046-115 Washer, Flat 1/2" 32
196-177-307 Chamber, Inner 2 901-046-308 Washer, Flat 1/2" 32
196-177-309 Chamber, Inner 2 42 901-048-115 Washer, Flat 3/8" 4
17 286-107-354 Diaphragm 2 901-048-308 Washer, Flat 3/8" 4

Not Shown:
535-069-000 Nameplate

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 13


RuppGUARD™ Option For Virgin PTFE
Equipped Pumps Drawing
S1F SPILL PREVENTION REPAIR PARTS LIST FOR VIRGIN
26
39
16 46 PTFE EQUIPPED PUMPS
14 36 Item Part Number Description Qty
34 43 170-114-115 Capscrew, Hex HD 3/8 - 16 x 4.50 16
(Replace 170-052-115)
6 170-114-308 Capscrew, Hex HD 3/8 - 16 x 4.50 16
17 41
29 (Replace 170-052-115)
10
10 44 196-159-552 Chamber, Spill Prevention 2
18 196-159-520 Chamber, Spill Prevention 2
41
36 45 286-094-600 Diaphragm, Pumping 2
50 46 518-180-520 Manifold, Spill Prevention 2
(Replace 518-179-520)
48 44 30 518-180-552 Manifold, Spill Prevention 2
(Replace 518-179-520)
45
47 538-022-110 Nipple, Pipe 4
538-022-308 Nipple, Pipe 4
48 560-078-611 O-ring 8
49 618-003-110 Plug, Pipe 4
618-003-308 Plug, Pipe 4
39 50 618-025-110 Plug, Boss 4
26 618-025-308 Plug, Boss 4
48 51 618-031-110 Plug, Boss 4
618-031-308 Plug, Boss 4
51 52 835-005-110 Tee, Pipe 4
53 48 835-005-308 Tee, Pipe 4
47
53 860-056-606 Tube, Sight 2
50 54 866-060-110 Connector, Tube 4
15 26
54 49 *Note: The Diaphragm is to be installed with the convex side facing toward
39 the outer chamber. See drawing.
52 39
43
41
Note: 10
Item 45
The diaphragm 10
is to be 41
installed with
the convex 36
side facing
toward the
outer
chambers.

46

36

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 14


RuppGUARD™ FOR VIRGIN PTFE the natural convex curve toward the is installed in the top end cap, fill the port of the outer chamber and applying
EQUIPPED PUMPS CONCEPT outer chamber (items 14 from the pump left spill containment chamber. If the pressure to the diaphragm. Loosen the
The spill prevention option prevents assembly drawing). The molded safety clip is installed on the bottom end pipe plug (item 49) allowing the fluid to
the air end components from being directional arrows on the diaphragms cap, fill the right spill prevention chamber. purge any remaining trapped air.
contaminated or damaged when a must point vertically. The volume of fluid is 1198 ml (40.49 fl. Reinstall the plug.
pumping diaphragm ruptures while oz.). It is important that the exact amount 10. Repeat steps 5 through 9 to fill
pumping caustic or toxic materials. It FILLING RuppGUARD™ CHAMBERS of fluid is used. Too little or too much opposite spill prevention chamber.
also helps to protect the environment. WITH LIQUID fluid causes premature diaphragm 11. Reinstall the check valve
With the installation of optional leak THE CHAMBERS ARE FILLED failure and erratic pumping. components, discharge manifold and
detectors (either mechanical or WITH WATER AT THE FACTORY. 6. Loosely reinstall one boss plug elbows to the pump. The pump is now
electronic) the diaphragm rupture can be If you prefer to substitute another (item 50) to the filled spill prevention ready for operation.
detected. The pump can then be shut liquid, to prevent system contamination chamber.
down and repaired before any caustic or consult the factory first to determine 7. Shut off air supply. Remove safety
toxic materials can enter the air end and compatibility of the substitute with pump clip. Adjust the air line regulator so that
be exhausted into the surrounding construction. air pressure slowly fills the pump. The
environment. Follow the steps listed here to replace diaphragm expands, forcing the fluid in IMPORTANT
the liquid in the pump after disassembly the chamber to be slowly displaced.
RuppGUARD™ OPTION DIAPHRAGM or liquid loss: When the pump shifts to the opposite Read these instructions
SERVICING side, quickly install the safety clip. completely, before in-
1. Drain the fluid in the spill stallation and start-up. It
To service the diaphragms first shut prevention chambers by removing the 8. Loosen the top boss plug on the is the responsibility of
off the suction, then shut off the bottom two boss plugs (items 50). filled chambers. This allows fluid in the the purchaser to retain
discharge lines to the pump. Next shut Replace the bottom two boss plugs after chamber to purge trapped air from the this manual for reference. Failure to
comply with the recommendations stated
off the compressed air supply, bleed the the fluid is drained. chamber. This can be seen by watching
in this manual will damage the pump, and
pressure from the pump, and disconnect 2. Remove the eight capscrews (item the column of fluid in the sight tube. When void factory warranty.
the air supply line from the pump. Drain 10) fastening the discharge manifold and fluid appears at the top of the port,
any remaining pumped liquid from the elbows to the outer chambers (items 15). quickly tighten the boss plug. Fluid loss
pump. Remove the pump before The discharge manifolds and elbows can of 1 to 2ml is acceptable.
servicing. now be removed. 9. Tilt the pump so the uppermost
Next, drain the fluid from the spill 3. Remove the top two boss plugs pipe tee (item 52) is in the vertical
prevention chambers. This can be done (items 50). The spill prevention position. Loosen the pipe plug (item 49).
by removing the bottom plug (item 50) chambers are filled through the exposed This will allow trapped air to purge
from each spill prevention chamber. ports. through the pipe tee. When fluid appears
After the fluid from the spill 4. Apply air pressure to the air at the tee opening, reinstall the pipe
prevention chambers has been drained, distribution valve. Install safety clip plug.
the wet end components can now be (item 1-K) into the smaller unthreaded NOTE: If all air is not purged using
removed. See diaphragm servicing hole in one end cap (item 1-E). This this procedure, remove the check valve
section for detailed instructions. The spill locks the valve spool to one side, components from the top port of the outer
prevention option has two additional keeping the pump from shifting. chamber (item 15). Apply manual
virgin PTFE pumping diaphragms (item 5. Face the side of the pump with pressure to the pumping diaphragm by
45). These diaphragms are installed with the installed safety clip. If the safety clip inserting a blunt instrument into the top

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 15


RuppGUARD™ Option For TPE
Equipped Pumps Drawing
46

36 S1F SPILL PREVENTION REPAIR PARTS LIST FOR TPE


26
16
EQUIPPED PUMPS
39
Item Part Number Description Qty
14 41
10 43 170-114-115 Capscrew, Hex HD 3/8 - 16 x 4.50 16
34 (Replace 170-052-115)
10
41
170-114-308 Capscrew, Hex HD 3/8 - 16 x 4.50 16
6 17
(Replace 170-052-115)
29 36
44 196-159-552 Chamber, Spill Prevention 2
50 196-159-520 Chamber, Spill Prevention 2
46 518-180-520 Manifold, Spill Prevention 2
48 44
(Replace 518-179-520)
518-180-552 Manifold, Spill Prevention 2
(Replace 518-179-552)
30 55 47 538-022-110 Nipple, Pipe 4
538-022-308 Nipple, Pipe 4
48 560-078-611 O-ring 8
49 618-003-110 Plug, Pipe 4
618-003-308 Plug, Pipe 4
39
50 618-025-110 Plug, Boss 4
26 618-025-308 Plug, Boss 4
48 51 618-031-110 Plug, Boss 4
618-031-308 Plug, Boss 4
51 52 835-005-110 Tee, Pipe 4
53 48 835-005-308 Tee, Pipe 4
47
53 860-056-606 Tube, Sight 2
50 54 866-060-110 Connector, Tube 4
15 26 55 286-092-354* Diaphragm, Pumping 2
54 49 18 286-108-600 Diaphragm, Overlay is not used 2
39 39
52 *Note: The Diaphragm is to be installed with the convex side facing toward
43
the outer chamber. See drawing.

Note: 41
10
Item 55
The diaphragm 10
is to be 41
installed with
the convex
side facing 36
toward the
outer
chambers.

46

36

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 16


RuppGUARD™ FOR TPE EQUIPPED concave curve toward the outer is installed in the top end cap, fill the 10. Repeat steps 5 through 9 to fill
PUMPS CONCEPT chamber (items 15 from the pump left spill prevention chamber. If the safety opposite spill prevention chamber.
The spill prevention option prevents assembly drawing). The molded clip is installed on the bottom end cap, 11. Reinstall the check valve
the air end components from being directional arrows on the diaphragms fill the right spill prevention chamber. components, discharge manifold and
contaminated or damaged when a must point vertically. 6. Loosely reinstall one boss plug elbows to the pump. The pump is now
pumping diaphragm ruptures while (item 50) to the filled spill prevention ready for operation.
pumping caustic or toxic materials. It FILLING RuppGUARD™ CHAMBERS chamber.
also helps to protect the environment. WITH LIQUID 7. Shut off air supply. Remove safety
With the installation of optional leak THE CHAMBERS ARE FILLED clip. Adjust the air line regulator so that
detectors (either mechanical or WITH WATER AT THE FACTORY. air pressure slowly fills the pump. The
electronic) the diaphragm rupture can be If you prefer to substitute another diaphragm expands, forcing the fluid in
detected. The pump can then be shut liquid, to prevent system contamination the chamber to be slowly displaced.
IMPORTANT
down and repaired before any caustic or consult the factory first to determine When the pump shifts to the opposite Read these instructions
toxic materials can enter the air end and compatibility of the substitute with pump side, quickly install the safety clip. completely, before in-
stallation and start-up. It
be exhausted into the surrounding construction. 8. Loosen the top boss plug on the
is the responsibility of
environment. Follow the steps listed here to replace filled chambers. This allows fluid in the the purchaser to retain
the liquid in the pump after disassembly chamber to purge trapped air from the this manual for reference. Failure to
RuppGUARD™ OPTION DIAPHRAGM or liquid loss: chamber. This can be seen by watching comply with the recommendations stated
in this manual will damage the pump, and
SERVICING 1. Drain the fluid in the spill the column of fluid in the sight tube. When
void factory warranty.
To service the diaphragms first shut prevention chambers by removing the fluid appears at the top of the port,
off the suction, then shut off the bottom two boss plugs (items 50). quickly tighten the boss plug. Fluid loss
discharge lines to the pump. Next shut Replace the bottom two boss plugs after of 1 to 2ml is acceptable.
off the compressed air supply, bleed the the fluid is drained. 9. Tilt the pump so the uppermost
pressure from the pump, and disconnect 2. Remove the eight capscrews (item pipe tee (item 52) is in the vertical
the air supply line from the pump. Drain 10) fastening the discharge manifold and position. Loosen the pipe plug (item 49).
any remaining pumped liquid from the elbows to the outer chambers (items 15). This will allow trapped air to purge
pump. Remove the pump before The discharge manifolds and elbows can through the pipe tee. When fluid appears
servicing. now be removed. at the tee opening, reinstall the pipe
Next, drain the fluid from the spill 3. Remove the top two boss plugs plug.
prevention chambers. This can be done (items 50). The spill prevention NOTE: If all air is not purged using
by removing the bottom plug (item 50) chambers are filled through the exposed this procedure, remove the check valve
from each spill prevention chamber. ports. components from the top port of the outer
After the fluid from the spill 4. Apply air pressure to the air chamber (item 15). Apply manual
prevention chambers has been drained, distribution valve. Install safety clip pressure to the pumping diaphragm by
the wet end components can now be (item 1-K) into the smaller unthreaded inserting a blunt instrument into the top
removed. See diaphragm servicing hole in one end cap (item 1-E). This port of the outer chamber and applying
section for detailed instructions. The spill locks the valve spool to one side, pressure to the diaphragm. Loosen the
prevention option has two additional TPE keeping the pump from shifting. pipe plug (item 49) allowing the fluid to
pumping diaphragms (item 55). These 5. Face the side of the pump with purge any remaining trapped air.
diaphragms are installed with the natural the installed safety clip. If the safety clip Reinstall the plug.

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 17


Air Distribution Valve Assembly Drawing
S1F Design Level 3
AIR VALVE ASSEMBLY PARTS LIST
Item Part Number Description Qty
1-J
1 031-140-000 Air Valve Assembly 1
1-H 1-A 031-139-000 Sleeve and Spool Set 1
1-B 095-094-551 Body, Air Valve 1
1-C 132-029-552 Bumper 2
1-D 165-096-551 Cap, Muffler 1
1-G 1-E 165-115-552 Cap, End 2
1-D
1-F 530-028-550 Muffler 1
1-G 560-020-360 O-ring 8
1-G
1-H 675-044-115 Ring, Retaining 2
1-E 1-J 710-015-115 Screw, Self-tapping 4
1-F 1-C
For Pumps with Alternate Mesh, Sound Dampening Mufflers or Piped
Exhaust:
1 031-141-000 Air Valve Assembly 1
1-A (Includes all items used on 031-140-000 minus
items 1-D, 1-F & 1-J)
1-A

1-B

1-C
1-E
1-G
1-H

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 18


AIR DISTRIBUTION VALVE Inspect the inner diameter of the
SERVICING sleeve (par t of item 1-A) for dirt, IMPORTANT
To service the air valve first shut off scratches, or other contaminates. Read these instructions
the compressed air, bleed the pressure Remove the sleeve if needed and completely, before in-
from the pump, and disconnect the air replace both the sleeve and spool with stallation and start-up. It
supply line from the pump. a new sleeve and spool set (item 1-A). is the responsibility of
the purchaser to retain
this manual for reference. Failure to
Step #1: See Composite Repair and Step #3: Reassembly of the air valve. comply with the recommendations stated
Parts Drawing. Install one bumper, (item 1-C) and in this manual will damage the pump, and
Using a 5/16" Allen wrench, remove one end cap (item 1-E) with an o-ring void factory warranty.
the four hex socket capscrews (item 13) (item 1-G) into one end of the air valve
and four flat washers (item 42). Remove body (item 1-B). Install one retaining ring
the air valve assembly (item 1) from the (item 1-H) into the groove on the same
pump. end.
Remove and inspect gasket (item 21) Remove the new sleeve an spool set
for cracks or damage. Replace gasket if (item 1-A) from the plastic bag. Carefully
needed. remove the spool from the sleeve. Install
the six o-rings (item 1-G) into the six
Step #2: Disassembly of the air valve. grooves on the sleeve. Apply a light
To access the internal air valve coating of grease to the o-rings before
components first remove the two retaining installing the sleeve into the valve body
rings (item 1-K) from each end of the air (item 1-B), align the slots in the sleeve
valve assembly using clip ring pliers. with the slots in the valve body. Insert
Next remove the two end caps (item the spool into the sleeve. Be careful not
1-E). Inspect the o-rings (item 1-G) for to scratch or damage the spool during
cuts or wear. Replace the o-rings if installation. Push the spool in until it
necessary. touches the bumper on the opposite end.
Remove the spool (part of item 1-A) Install the remaining bumper, end cap
from the sleeve. Be careful not to stratch with o-ring, and retaining ring.
or damage the outer diameter of the Fasten the air valve assembly (item
spool. Wipe spool with a soft cloth and 1) and gasket (item 21) to the pump.
inspect for scratches or wear. Connect the compressed air line to
the pump. The pump is now ready for
operation.

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 19


Air Valve Assembly Drawing With Stroke Indicator Option
S1F Design Level 3
AIR VALVE ASSEMBLY PARTS LIST
Item Part Number Description Qty
1 031-146-000 Air Valve Assembly 1
1-A 031-143-000 Sleeve and Spool Set 1
1-B 095-094-551 Body, Air Valve 1
1-C 132-029-552 Bumper 2
1-D 165-096-551 Cap, Muffler 1
1-E 165-098-147 Cap, End 2
1-F 530-028-550 Muffler 1
1-G 560-020-360 O-ring 8
1-H 675-044-115 Ring, Retaining 2
1-J 710-015-115 Screw, Self-tapping 4
1-K 210-008-330 Clip, Safety 1
1-M 560-001-360 O-ring 2

For Pumps with Alternate Mesh, Sound Dampening Mufflers or Piped


Exhaust:
1 031-147-000 Air Valve Assembly 1
(Includes all items used on 031-140-000 minus
items 1-D, 1-F & 1-J)

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 20


AIR DISTRIBUTION VALVE WITH scratches, or other contaminates.
STROKE INDICATOR OPTION Remove the sleeve if needed and IMPORTANT
SERVICING replace both the sleeve and spool with Read these instructions
To service the air valve first shut off a new sleeve and spool set (item 1-A). completely, before in-
the compressed air, bleed the pressure stallation and start-up. It
from the pump, and disconnect the air Step #3: Reassembly of the air valve. is the responsibility of
the purchaser to retain
supply line from the pump. Install one bumper (item 1-C) and this manual for reference. Failure to
one end cap (item 1-E) with an o-ring comply with the recommendations stated
Step #1: See Composite Repair and (item 1-G) into one end of the air valve in this manual will damage the pump, and
Parts Drawing. body (item 1-B). Install one retaining ring void factory warranty.
Using a 5/16" Allen wrench, remove (item 1-H) into the groove on the same
the four hex socket capscrews (item 13) end. Insert the safety clip (item 1-K)
and four flat washers (item 42). Remove through the small unthreaded hole in the
the air valve assembly (item 1) from the end cap.
pump. Remove the new sleeve an spool
Remove and inspect gasket (item 21) set (item 1-A) from the plastic bag.
for cracks or damage. Replace gasket if Carefully remove the spool from the
needed. sleeve. Install the six o-rings (item 1-G)
into the six grooves on the sleeve. Apply
Step #2: Disassembly of the air valve. a light coating of grease to the o-rings
To access the internal air valve before installing the sleeve into the valve
components first remove the two retaining body (item 1-B), align the slots in the
rings (item 1-K) from each end of the air sleeve with the slots in the valve body.
valve assembly using clip ring pliers. Insert the spool into the sleeve. Be
Next remove the two end caps (item careful not to scratch or damage the
1-E). Inspect the o-rings (item 1-G) for spool during installation. Push the spool
cuts or wear. Replace the o-rings if in until the pin touches the safety clip
necessary. on the opposite end.
Remove the spool (part of item 1-A) Install the remaining bumper, end cap
from the sleeve. Be careful not to scratch with o-ring, and retaining ring.
or damage the outer diameter of the Fasten the air valve assembly (item
spool. Wipe spool with a soft cloth and 1) and gasket (item 21) to the pump.
inspect for scratches or wear. Connect the compressed air line to
Inspect the inner diameter of the the pump. The pump is now ready for
sleeve (par t of item 1-A) for dirt, operation.

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 21


Solenoid Shifted Air Valve Drawing
SOLENOID SHIFTED AIR VALVE PARTS LIST
(Includes All Items Used on Composite Repair Parts List Except as Shown)
Item Part Number Description Qty
56 893-097-000 Solenoid Valve, NEMA4 1
57 219-001-000 Solenoid Coil, 24VDC 1
219-004-000 Solenoid Coil, 24VAC / 12VDC 1
219-002-000 Solenoid Coil, 120VAC 1
219-003-000 Solenoid Coil, 240VAC 1
58 241-001-000 Connector, conduit 1
59 170-029-330 Capscrew, Hex HD 5/16 - 18 x 1.50 4
60 618-051-150 Plug 2
For Explosion Proof Solenoid Valve 56
(Connector not required for explosion proof coil; coil is integral with valve)
56 893-098-001 Solenoid Valve, NEMA 7/9, 24VDC 1
893-098-002 Solenoid Valve, NEMA 7/9, 24VAC / 12VDC 1 57
58
893-098-003 Solenoid Valve, NEMA 7/9, 120VAC 1
893-098-004 Solenoid Valve, NEMA 7/9, 220VAC 1

59

60

56

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 22


SOLENOID SHIFTED AIR
DISTRIBUTION VALVE OPTION Wiring
Solenoid Connector
Warren Rupp’s solenoid shifted, air Diagram
distribution valve option utilizes electrical 3rd Terminal
signals to precisely control your for ground.
Before wiring,
SandPIPER’s speed. The solenoid coil remove terminal
block from conduit #1 Terminal
is connected to the Warren Rupp #2 Terminal
connector. Power
Solenoid Rate Controller/Batch Control, Neutral (Positive)
or a customer - supplied control. (Negative)
Compressed air provides the pumping
power, while electrical signals control
pump speed (pumping rate).

OPERATION
The Solenoid Shifted SandPIPER has
a solenoid operated, air distribution valve
in place of the standard SandPIPER’s
pilot operated, air distribution valve.
Where a pilot valve is normally utilized
to cycle the pump’s air distribution valve,
an electric solenoid is utilized. As the
solenoid is powered, one of the pump’s
air chambers is pressurized while the
other chamber is exhausted. When
electric power is turned off, the solenoid
shifts and the pressurized chamber is
exhausted while the other chamber is
pressurized. By alternately applying and
removing power to the solenoid, the
pump cycles much like a standard
SandPIPER pump, with one exception.
This option provides a way to precisely
control and monitor pump speed.

BEFORE INSTALLATION
Before wiring the solenoid, make certain
it is compatible with your system
voltage.

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 23


Pilot Valve Assembly Drawing

PILOT VALVE ASSEMBLY PARTS LIST


Item Part Number Description Qty
4 095-096-558 Pilot Valve Assembly
4-A 095-095-558 Body, Pilot Valve 1
4-B 135-037-506 Bushing 2
4-C 675-057-115 Ring, Spiral Retaining 2
4-D 770-065-175 Spacer 5
4-E 775-041-506 Spool, Pilot 1
4-F 917-003-374 Wiper 6

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 24


PILOT VALVE SERVICING Step #3: Re-assembly of the pilot Step #5: Re-install the pilot valve
To service the pilot valve first shut valve. ssembly into the intermediate assembly. IMPORTANT
off the compressed air supply, bleed the First install a spiral retaining ring to Be careful to align the ends of the Read these instructions
pressure from the pump, and disconnect one end of the pilot valve body. Spread stem between the plungers when completely, before in-
the air supply line from the pump. Insert the spiral and insert one end into the inserting the stem of the pilot valve into stallation and start-up. It
the safety clip (item 1-F from Air groove in the pilot valve body. Twist the the cavity of the intermediate. is the responsibility of
the purchaser to retain
Distribution Valve assembly drawing) ring in a clockwise motion until the full Re-install the gasket (item 23), air this manual for reference. Failure to
into the smaller unthreaded holes in the ring is snapped into the groove. Install inlet cap (item 8), capscrews and comply with the recommendations stated
end cap (item 1-D from air distribution one bushing making sure the step side washers (items 12 and 40). in this manual will damage the pump, and
valve assembly drawing). faces toward the wiper. Apply a light Connect the air supply to the pump. void factory warranty.
coating of grease to the outside Remove the safety clip (item 1-F) from
Step #1: See PUMP ASSEMBLY diameter of each wiper. Next, gently push the end cap (item 1-D). The pump is now
DRAWING. in the wipers and spacers until they are ready for operation.
Using a 9 /16" wrench or socket, against the installed retaining ring in the
remove the four capscrews (items 12) opposite end of the pilot valve body.
and four flat washers (items 40). Remove Install the remaining bushing making
the air inlet cap (item 8) and air inlet sure the step side faces the wiper. Install
gasket (item 23). The pilot valve the remaining spiral retaining ring using
assembly (item 4) can now be removed the same method described.
for inspection or service. Apply a light coating of grease to the
inner diameter of each wiper. Also apply
Step #2: Disassembly of the pilot a light coating of grease to the outer
valve. diameter of the pilot valve spool and
Remove the pilot valve spool (item gently push the spool through each wiper.
4-E). Wipe clean, and inspect for dirt,
scratches or wear. Replace the spool if Step #4: Inspect the actuator
necessary. plungers.
Remove the two spiral retaining rings See PUMP ASSEMBLY DRAWING.
(items 4-C) from each end of the pilot The actuator plungers (items 31) can
valve body by inserting the tip of a small be reached through the stem cavity of
flat screw driver under the notch in the the pilot valve in the intermediate
retaining ring. Lift and push the ring assembly (item 5).
clockwise in a circular motion. Remove the plungers (items 31) from
Remove the two pilot valve bushings the bushings (item 7) in each end of the
(items 4-B), five spacers (items 4-D), cavity. Inspect the installed o-ring (items
and six spool wipers (items 4-F) by 28) for cuts and/or wear. Replace the
pushing gently from other end of the o-rings if necessary. Apply a light coating
pilot valve body. Inspect the wipers for of grease to each o-ring and re-install
cuts and/or wear. Replace any wipers the plungers in to the bushings. Push
as necessary. the plungers in as far as they will go.

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 25


Diaphragm Service Drawing, Diaphragm Service Drawing,
Non-Overlay with Overlay

34

34
6

6 18

29
15
15

29
17

17 30 30

15 15

39
39
11 39
11 39
26
26

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 26


DIAPHRAGM SERVICING loosely into a vise. Use a 13/8" wrench On the opposite side of the pump,
To service the diaphragms first shut or socket to remove the outer diaphragm pull the diaphragm rod out as far as IMPORTANT
off the suction, then shut off the plate (item 30) by turning counter- possible. Make sure the bumper (item Read these instructions
discharge lines to the pump. Shut off the clockwise. Inspect the diaphragm (item 6) is installed over the diaphragm rod. completely, before in-
compressed air supply, bleed the 17) for cuts, punctures, abrasive wear Thread the stud of the remaining stallation and start-up. It
pressure from the pump, and disconnect or chemical attack. Replace the diaphragm assembly clockwise into the is the responsibility of
the purchaser to retain
the air supply line from the pump. Drain diaphragms if necessary. tapped hole at the end of the diaphragm this manual for reference. Failure to
any remaining liquid from the pump. rod (item 34) as far as possible and still comply with the recommendations stated
Step #4: Installing the diaphragms. allow for alignment of the bolt holes in in this manual will damage the pump, and
Step #1: See the pump composite Push the threaded stud of the outer the diaphragm with the bolt pattern in void factory warranty.
repair parts drawing, and the diaphragm diaphragm plate through the center hole the inner chamber. The molded
servicing illustration. of the diaphragm. Thread the inner plate directional arrows on the diaphragm must
Using a 9/16 " wrench or socket, clockwise onto the stud. Use a torque point vertically.
remove the 16 capscrews (items 9), hex wrench to tighten the diaphragm Fasten the remaining outer chamber
nuts and washers that fasten the elbows assembly together to 20 ft. Lbs. (27.11 (item 15) to the pump, using the
(items 19 and 20) to the outer chambers Newton meters). Allow a minimum of 15 capscrews (items 11), hex nuts and flat
(items 15). Remove the elbows with the minutes to elapse after torquing, then washers.
manifolds and spacers attached. re-torque the assembly to compensate
for stress relaxation in the clamped Step #6: Re-install the elbow/spacer/
Step #2: Removing the outer assembly. manifold assemblies to the pump, using
chambers. the capscrews (items 9), hex nuts and
Using a 9/16 " wrench or socket, Step #5: Installing the diaphragm flat washers.
remove the 16 capscrews (items 11), hex assemblies to the pump.
nuts and washers that fasten the outer Make sure the bumper (item 6) is The pump is now ready to be re-
chambers, diaphragms, and inner installed over the diaphragm rod. installed, connected and returned to
chambers (items 16) together. Thread the stud of the one diaphragm operation.
assembly clockwise into the tapped hole
Step #3: Removing the diaphragm at the end of the diaphragm rod (item 34) OVERLAY DIAPHRAGM SERVICING
assemblies. until the inner diaphragm plate is flush to The PTFE overlay diaphragm (item
Use a 13/8" (35mm) wrench or six the end of the rod. Insert rod into pump. 18) is designed to fit snugly over the
pointed socket to remove the diaphragm Align the bolt holes in the diaphragm exterior of the standard TPE diaphragm
assemblies (outer plate, diaphragm, and with the bolt pattern in the inner chamber (item 17).
inner plate) from the diaphragm rod (item (item 16). Make sure the molded The molded directional arrows on the
34) by turning counterclockwise. directional arrows on the diaphragm point overlay diaphragm must point vertically.
Insert a 1/4-20 capscrew or set screw vertically. Follow the same procedures
into the smaller tapped hole in the inner Fasten the outer chamber (item 15) described for the standard diaphragm for
diaphragm plate (item 29). Insert the to the pump, using the capscrews (items removal and installation.
protruding stud and the 1/4-20 fastener 11), hex nuts and flat washers.

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 27


PUMPING HAZARDOUS LIQUIDS IMPORTANT INSTALLATION NOTE: CONVERTED EXHAUST ILLUSTRATION
When a diaphragm fails, the pumped The manufacturer recommends installing
PUMP INSTALLATION AREA
liquid or fumes enter the air end of the a flexible hose or connection between SAFE AIR
pump. Fumes are exhausted into the the pump and any rigid plumbing. This EXHAUST
DISPOSAL
surrounding environment. When pumping reduces stresses on the molded plastic AREA
hazardous or toxic materials, the threads of the air exhaust port. Failure
1" DIAMETER AIR
exhaust air must be piped to an to do so may result in damage to the air EXHAUST PIPING
appropriate area for safe disposal. See distribution valve body. MUFFLER
illustration #1 at right. Any piping or hose connected to the
This pump can be submerged if the pump’s air exhaust por t must be
pump materials of construction are physically supported. Failure to support
compatible with the liquid being pumped. these connections could also result in Illustration #1
The air exhaust must be piped above damage to the air distribution valve body.
the liquid level. See illustration #2 at
right. Piping used for the air exhaust must
not be smaller than 1" (2.54 cm) Exhaust Conversion Drawing
MUFFLER
diameter. Reducing the pipe size will
restrict air flow and reduce pump
performance. When the pumped product
1" DIAMETER AIR
source is at a higher level than the pump LIQUID EXHAUST PIPING
(flooded suction condition), pipe the LEVEL
exhaust higher than the product source
to prevent siphoning spills. See SUCTION
illustration #3 at right. LINE

CONVERTING THE PUMP FOR Illustration #2


PIPING THE EXHAUST AIR
The following steps are necessary to
convert the pump to pipe the exhaust
air away from the pump.
Use a #8 Torx or flat screwdriver to MUFFLER

remove the six self-tapping screws (item


1-L).
Remove the muffler cap and muffler 1" DIAMETER AIR
LIQUID EXHAUST PIPING
(items 1-E and 1-G). The 1" NPT molded LEVEL
threads in the air distribution valve body
(item 1-B).
SUCTION
Piping or hose may now be installed. LINE

Illustration #3

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 28


MODULAR CHECK VALVE
SERVICING
Modular Check Valve Drawing
Before servicing the check valves, Remove the remaining check valve
first shut off the suction line and then seal (item 37). Inspect the seal for cuts
the discharge line to the pump. Next, shut or pinched areas. Replace seal as
off the compressed air supply, bleed air needed. 9
pressure from the pump, and disconnect Re-assemble the modular check
the air supply line from the pump. Drain valve. The seat should fit snugly into the
any remaining fluid from the pump. The retainer.
39 41
pump can now be removed for service. Place a check valve seal (item 37)
To access the modular check valve, into the cavity of the outer chamber (item
remove the elbows (items 19 and 20 15). Make sure the chamfer side of the 27
from pump composite repair parts seal faces out. Insert the modular check
drawing). Use a 9/16" wrench or socket to valve into the outer chamber with the
remove the fasteners. Once the elbows retainer facing up. Install a check valve
are removed, the modular check valves seal (item 37). Make sure the chamfer
can be seen in the cavities of the outer side of the seal faces the chamfer on
chamber (items 15). the check valve seat or retainer.
Next remove the check valve seal The pump can now reassembled, 19
(item 37). Inspect the seal for cuts or reconnected and returned to operation.
pinched areas. Replace seal as needed.
Disassemble the component parts of 37
each modular check valve. Inspect the
check valve retainer (item 32) for cuts,
abrasive wear, or embedded materials. 32
Replace as needed.
Inspect the check balls (items 2) for
wear, abrasion, or cuts on the spherical 2
surface. The check valve seats (items
38) should be inspected for cuts, 38
abrasive wear, or embedded material on
the surfaces of both the external and
37
internal chamfers. The spherical surface
of the check balls must seat flush to
the surface of the inner chamfer on the
check valve seats for the pump to 15
operate to peak efficiency. Replace any
worn or damaged parts as necessary.

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 29


Dual Port Option Drawing

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 30


DUAL PORTING OPTIONS SINGLE PORTING OF THE SUCTION
Several dual porting options are AND DUAL PORTING OF THE PUMP IMPORTANT
possible. The pump can be converted DISCHARGE Read these instructions
to a dual port arrangement on both the To conver t the pump from the completely, before in-
suction and the discharge ends. The standard single suction and single stallation and start-up. It
porting can be configured to a single discharge porting configuration to a dual is the responsibility of
the purchaser to retain
suction and a dual discharge. The porting discharge porting arrangement remove this manual for reference. Failure to
can be changed to a dual suction and a the only the discharge manifolds, comply with the recommendations stated
single discharge. spacers, and manifold seals. Position the in this manual will damage the pump, and
The above changes are possible discharge elbows in the desired direction void factory warranty.
because the porting flange of the elbows at 90° increments. (See arrows and
(items 19 and 20) are designed to mate optional positioning in the Dual Porting
with standard 125# ANSI style 4-bolt, Drawing.)
1" pipe flanges.

DUAL PORTING OF BOTH SUCTION DUAL PORTING OF THE SUCTION


AND DISCHARGE ENDS OF THE AND SINGLE PORTING OF THE PUMP
PUMP DISCHARGE
Converting the pump from the To conver t the pump from the
standard single suction and discharge standard single suction and single
porting configuration to dual porting at discharge porting configuration to a dual
each end is easy. Simply remove the suction porting arrangement remove the
manifold seals, spacers, and manifolds only the suction (bottom) manifolds,
(items 36 and 24 from pump assembly spacers, and manifold seals.
drawing) from the pump. Position the suction elbows in the
The discharge and suction elbows desired direction at 90° increments. (See
can be rotated at 90° increments (see arrows and optional positioning in the
arrows and optional positioning in the Dual Porting Drawing.)
Dual Porting Drawing.

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 31


RuppTech® Leak Detection Options Drawing

44

710-014-330
Self-tapping Screws
(Qty of 2)

53

54
52

49

MUFFLER CAP

RuppTech® LEAK DETECTION OPTION A (ELECTRONIC)

Follow instructions found elsewhere in this manual, “Filling the RuppGUARD™


For pumps 530-028-550 Spill Prevention Chambers” when installing leak detectors.
Enclosed Muffler
Electronic Leak Detector Installation
Kit 032-037-000 100VAC 50Hz
or 110-120VAC 50 / 60Hz
or 220-240VAC 50 / 60Hz
Kit 032-045-000 12-32VDC
For pumps with Alternate Mufflers To install electronic leak detectors, remove the bottom ¼" NPT pipe plug on the
visual sight tube (item 53). Insert leak detector into the ¼" pipe tee (item 52).

Leak Detection Option B (Mechanical)


Follow instructions found elsewhere in this manual, “Filling the RuppGUARD™
Spill Prevention Chambers” when installing leak detectors.

Mechanical Leak Detector Installation


Kit 031-023-110
To install mechanical leak detectors, remove the bottom ¼" NPT pipe plug on the
visual sight tube (item 53). Insert leak detector into the ¼" pipe tee (item 52).

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 32


RuppTech® Pulse Output Kit Drawing
PULSE OUTPUT KIT OPTION
This pump can be fitted with a Pulse Output Kit. This converts the mechanical strokes of the
pump to an electrical signal which interfaces with the RuppTech® Stroke Counter/ Batch Controller
or user control devices such as a PLC.
The Pulse Output Kits mount directly onto the Muffler Cap on the Air Distribution Valve Assembly
or onto the Air Distribution Valve Assembly when the threaded exhaust port or an auxiliary muffler is
being used.
See the individual kits listed on the Pump Repair Parts List for further information.

Exhaust Port or Auxiliary Integral Muffler Setup


Muffler Setup Pulse Output Kit

Muffler Cap

Pulse Output Kit

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 33


Optional Muffler Configurations, Drawing

CONFIGURATION A
530-028-550 Encapsulated Muffler uses (1)
165-096-551 Cap and (4) 710-015-115 Self
Tapping Screw to hold it in place.

CONFIGURATION B
530-010-000 Mesh Muffler screws
directly into the Air Valve Body. This
muffler is equipped with a metal element.

CONFIGURATION C
530-027-000 Sound Dampening Muffler
screws directly into the Air Valve body.
This muffler is equipped with a porous
plastic element.

CONFIGURATION A CONFIGURATION B AND C

520-199-000 7/02 Model S1F Non-Metallic Design Level 3 Page 34