HMT360 Humidity and Temperature Transmitter series Probes

1 2 3 4 5 6 7
Vaisala HUMICAP® Humidity and Temperature Probe HMP360 A PRICE
1 Probe type HMP361 for wall mounting 1
HMP363 for general use 3
HMP364 for pressurized processes 4
HMP365 for high temperatures 5
HMP367 for high humidities 7
HMP368 for pressurized pipelines 8
2 Probe and cable length HMP361 no cable max +60°C A
HMP363, +80°C 2 m cable max +80°C 1
5 m cable max +80°C 2
10 m cable max +80°C 3
HMP363, +120°C 2 m cable max 120°C B
5 m cable max +120°C C
10 m cable max +120°C D
HMP364 2 m cable max +180°C E
5 m cable max +180°C F
10 m cable max +180°C G
HMP365 2 m cable max +180°C H
5 m cable max +180°C J
10 m cable max +180°C K
Probe

HMP367 2 m cable max +180°C V


5 m cable max +180°C W
10 m cable max +180°C X
HMP368 2 m cable 226 mm probe, max 180°C L
5 m cable 226 mm probe, max +180°C M
10 m cable 226 mm probe, max +180°C N
2 m cable 448 mm probe, max 180°C P
5 m cable 448 mm probe, max +180°C Q
10 m cable 448 mm probe, max +180°C R
3 Sensor type HUMICAP 180 1
HUMICAP 180L2 2
HUMICAP 180R 5
4 A
5 Sensor protection PPS plastic grid & stainless steel netting (recommended choice) 1
PPS plastic grid 2
Sintered stainless steel filter 3
6 Installation kit No kit A
HMP363 Duct installation kit for HMP363&367 B
HMP365 Mounting flange D
HMP368 Ball valve set E
HMP363/367 Cable Gland AGRO J
HMP364 Fitting body M22x1.5 male K
HMP364 Fitting body NPT 1/2" male G
HMP367 Swagelok NPT 1/2" L
HMP367 Swagelok ISO 3/8" M
HMP368 Fitting Body ISO1/2 N
HMP368 Fitting Body NPT1/2" H
7 Ex certification and issuer ATEX 100a 94/9/EC (PTB) 2
Factory Mutual (USA) 4
CSA (Canada) 5
TIIS (Japan) 7
TOTAL
QTY
TOTAL VALUE

NOTE: Intrinsically Safe barriers are required with the HMT360 to achieve a safe installation. The following Stahl barrier is acceptable, if the supply voltage
to the barrier is between 24 - 35 VDC, the cable length between transmitter and barrier is less than 300m, and the external load created by additional
components in the loop is less than 200 ohms. If the installation requirements do not satisfy these parameters, then please consult the HMT360
manual (www.vaisala.com) or contact a manufacturer of safety barriers for additional assistance.

Accessories and Spare Parts : Description Order Code: PRICE


Stahl Zener Barrier (Stahl # 9001/51-280-091-141) 210664
(active barrier that requires active input)
Vyniker enclosure 210665
(enclosure holds 2 barriers)
HUMICAPâ humidity sensors
For measuring relative humidity

Features

• A capacitive thin-film polymer


sensor
• Full measurement range
0 … 100 %RH
• Accurate to ±0.8 %RH 1)
• Traceable humidity measurement
• Over 40 years on the market

1) Accuracy up to ±0.8 %RH depending on


product

Vaisala HUMICAPâ humidity sensors guarantee quality and reliability, with their
reputation for accuracy, excellent long-term stability, and negligible hysteresis.

Benefits How the HUMICAPâ sensor Vaisala HUMICAPâ humidity


works products
• Excellent long-term stability
HUMICAPâ is a capacitive thin-film Vaisala has everything you need for
• Insensitive to dust and most polymer sensor consisting of a substrate measuring humidity, with a wide range of
chemicals on which a thin film of polymer is humidity instruments covering
• Chemical purge option for stable deposited between two conductive applications from HVAC to the most
measurements in environments electrodes. The sensing surface is coated demanding industrial applications, both
with high concentrations of with a porous metal electrode to protect indoors and out. Vaisala’s humidity
chemicals it from contamination and exposure to instrument offering includes
condensation. The substrate is typically transmitters, modules for volume
• Sensor heating for measurements
glass or ceramic. The thin-film polymer applications, portable and handheld
even in condensing environments
either absorbs or releases water vapor as humidity meters, and humidity
• Full recovery from condensation the relative humidity of the ambient air calibrators.
rises or falls. The dielectric properties of
the polymer film depend on the amount
Upper electrode
of absorbed water. As the relative
humidity around the sensor changes, the
Thin-film polymer
dielectric properties of the polymer film
Lower electrode
change, and so does the capacitance of
Glass substrate
the sensor. The instrument’s electronics
measure the capacitance of the sensor
and convert it into a humidity reading.
Humidity sensor types

INTERCAPâ Interchangeable general purpose humidity sensor with good humidity durability and short response time.
humidity sensor

HUMICAPâ 180C Composite 1) general purpose humidity sensor with good humidity durability and short response time. The item contains humidity and
composite humidity and temperature sensors. This sensor is used for chemical purge and heated probe options.
temperature sensor

HUMICAPâ 180R Robust general purpose humidity sensor with high humidity durability, good long term stability, and good tolerance against chemical
humidity sensor exposure.

HUMICAPâ 180RC Robust composite general purpose humidity sensor. The HUMICAPâ 180RC has high humidity durability, good long term stability, and
composite humidity and good tolerance against chemical exposure. The item contains humidity and temperature sensors. This sensor is used for chemical purge
temperature sensor and heated probe options.

HUMICAPâ 180L2 Moisture measurement sensor for oils and other liquids. It has excellent tolerance against chemicals and moderate high humidity
moisture in oil sensor tolerance.

HUMICAPâ R2 The latest generation industrial humidity sensor. Compared to HUMICAPâ 180R it has improved corrosion resistance.
humidity sensor

HUMICAPâ 180V Humidity sensor with catalytic surface for use in processes with H2O2.
catalytic humidity sensor

HUMICAPâ 180VC Composite humidity sensor with catalytic surface for use in processes with H2O2.
catalytic composite
humidity and temperature
sensor

1) With integral Pt100 sensor.

Sensor properties

Integral Pt100 Encapsulation Identifying Item code


temp. sensor type character

INTERCAPâ Type C I 15778HM (1 pc) 1)


INTERCAPSET-10PCS (10 pcs)

HUMICAPâ 180C X Type C I 229011SP

HUMICAPâ 180R Type C R HUMICAP180R

HUMICAPâ 180RC X Type C R HUMICAP180RC

HUMICAPâ 180L2 Type D L HUMICAP180L2

HUMICAPâ R2 Type D R2 HUMICAPR2

HUMICAPâ 180V Type D C HUMICAP180V

HUMICAPâ 180VC X Type D C HUMICAP180VC

1) After the latest sensor update, the INTERCAPâ humidity sensor has been upgraded to the same environmental tolerance as the discontinued
HUMICAPâ 180 humidity sensor. Please use spare part item 15778HM (INTERCAPâ humidity sensor) as replacement for the HUMICAPâ 180 sensor.
Technical data
Materials

• All materials comply with UL V-0


• Thin film capacitor structure on glass substrate (Type C) or alumina (Type D)
• Sensor frame is made of lubricated 30 % glass reinforced LCP resin (white LCP Zenite 6130L)
• Sensor pin material is copper alloy with electroplated gold coating
• Sensor chip is attached to pins using silver-filled epoxy glue
• Glue is protected with white thermal curing marking ink

Dimensions
5.74 2 5.74 2
mm

15.2

15.2
5

1 G342 3 G342
2 R452 4 C00E

0.45 0.45
3.7

3.7
0.6 0.6

2.54 2.54

Sensor batch code: Sensor batch code: Sensor identification:


G = Year code G = Year code 5
1 R2 = HUMICAP R2
3
34 = Week number 34 = Week number
2 = Day code 2 = Day code

Sensor identification: Sensor identification:


2 I = INTERCAP / HUMICAP 180C 4 C = HUMICAP 180V / HUMICAP 180VC
R = HUMICAP 180R / HUMICAP 180RC L = HUMICAP 180L2

Type C (left) and type D (right)


encapsulation dimensions

Published by Vaisala | B211748EN-C © Vaisala 2021

All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners.
www.vaisala.com Any reproduction, transfer, distribution or storage of information contained in this document is strictly