Professional Documents
Culture Documents
Dental Catalog-2019-Web
Dental Catalog-2019-Web
Dental Catalog-2019-Web
2 3
content
CONTENT
STANDARD PLATFORM:........................................................................................................ 57
Index chart ................................................................................................................................. 58
Healing caps ............................................................................................................................... 60
Impressions ................................................................................................................................ 61
Cement Retained Restoration ................................................................................................... 65
Screw Retained Restoration ...................................................................................................... 81
Overdenture Restoration ............................................................................................................ 93
CAD/CAM Products ............................................................................................................... 77,89
A.B. Dental Devices' products are cleared for marketing by the FDA and are CE-marked in accordance with the Council Directive 93/42/EEC and Amendment 2007/47/EC.
The products availability may vary between countries according to each local regulatory approval.
A.B. Dental Devices' complies with EN ISO 13485:2016 and the Canadian Medical Devices Conformity Assessment System (CMDCAS).
IMPLANTS ADVANTAGES
(short/long/wide), each one has a unique design to meet the
requirements of each dentist and patient.
Double platform:
The implants are designed
One Piece Implants Platform switching: to accommodate two
Restoration of implants restorative platforms:
with diameter-reduced Deep connection (Internal
abutments, for Hexagon 1.8 mm), suitable
Conical Platform improved preservation gum abutment
for all abutments with
4 mm diameter of crestal bone levels antirotational hexagon.
and increasing the Flat connection (0.2 mm),
implant
soft tissue volume bone designed for non-engaging
contributes to abutments (Non hexagon).
Narrow Platform long-term esthetic
3 mm diameter outcomes.
100µm 50µm
TWO threads:
30µm 20µm
Flat thread that enables the
strongest initial stability.
Two Piece Implants
Sharp thread that enables the
(Double Platform)
insertion of the implant easily
3.75 mm diameter
and with minimal trauma to
the bone
8 9
IMPLANTOLOGY
IMPLANTOLOGY
MATERIAL REFERENCES:
All A.B. Dental implants are made of Titanium alloy Ti-6Al-4V ELI in accordance with Albrektsson T, Wennerberg A. Oral implant surfaces: Part 1-review focusing on
ASTM-F136-02 standard specification. topographic and chemical properties of different surfaces and in vivo responses
Titanium is a proven ideal implant material, mainly due to its ability to integrate almost to them. Int J Prosthodont 2004;17(5):536-43.
completely with the bone. In addition to being “bio-friendly”, it provides favorable mechanical Coelho PG, Granjeiro JM, Romanos GE, Suzuki M, Silva NR, Cardaropoli G,
qualities (strength, endurance) and can be precisely fabricated (precision measured in microns) Thompson VP, Lemons JE. Basic research methods and current trends of dental
to ensure a range of implants that meet the requirements for optimizing stability in the widest implant surfaces. J Biomed Mater Res B Appl Biomater 2009;88(2):579-96.
range of patients (considering the dimensions and state of health of an individuals’ bone and Lemons JE Biomaterials, biomechanics, tissue healing, and immediate-
gums). function dental implants. J Oral Implantol 2004;30(5):318-24.
BIOLOGICAL SURFACE
Figure 1: 100µm 50µm
A.B. Dental implants undergoes a special treatment of Biological blasting with calcium Scanning electron micrographs of the biological
phosphate for surface roughening, to enhance the direct attachment of the bone to the implant surface. The bioactive ceramic media blasting
(Osseointegration), as supported by the following quote from an article that compared different with mild gradative multi-step cleaning assures a
surface treatments: moderately rough surface. The surface treatment
“As the implant surface is the first part of the device to contact the host’s biological fluids, it is results in surface texturization in the micrometer
expected that its properties will affect the early healing between host and implant” (Albrektsson and nanometer level, maximizing the interaction
& Wennenberg, 2004). between surface and biological fluids immediately after
implantation, and load bearing capability after Osseo
“Over the years, implant surfaces have evolved from smooth as-turned surfaces towards integration establishment.
textured surfaces. Surface texturization may be achieved through a series of methods such as 30µm 20µm
acid-etching, grit-blasting, anodizing, and others” (Albrektsson & Wennenberg; Coelho et al.,
2009). “However, concerns regarding the final surface biocompatibility have been expressed”
(Lemons, 2004). Figure 2:
“The new biological surface, offered by A.B. Dental, combines all the technological innovations Representative three-dimensional
within one surface resulting in biological advantages. topographical reconstruction showing
The wide particle range bioactive ceramic media blasting with mild gradative multi-step texturization at the micrometer and the
cleaning assures a moderately rough surface (Figures 1 and 2) along with a highly biocompatible nanometer level.
surface chemistry where only Osseo conductive and biocompatible elements can be detected”
(Figure 3).
(Albrektsson & Wennenberg, 2004).
Figure 3:
Surface specific spectroscopy detecting
only the elements of the implant with
no contamination.
10
GUIDEDSERVICE ABGuidedService is an
exclusive service that assists
the dentist, to plan a precise
The 3D imaging and
planning is prepared
at A.B. Dental’s
implantation procedure easily, World Center
using the latest technology
A surgical guide
is printed digitally
from the 3D
plan, to bring the
planning to the
mouth
The ABGuide comes with the The guide can be tooth, soft
implants, prosthetic parts, tissue or bone supported, and
surgical kit and even temporary can be for any case, from 1
bridge, for each case implant to a full jaw
12 13
ABGUIDEDSERVICE
ABGUIDEDSERVICE
order online
14 15
ABGUIDEDSERVICE
ABGUIDEDSERVICE
1
Single Tooth Tooth supported
Multiple Implants Tooth and Soft tissue supported [free end]
Angled Implants Soft tissue supported [edentulous] The doctor orders an ABGuide using free
and easy to use ABDenpax software
Edentulous Bone supported
Pterygoid Tooth and Bone supported
Zygoma
All cases with or without Flap
2
CT scan and 3D planning by ABGuided Service.
Most cases without CT Guide. ABGuide is
produced digitally from the approved plan.
OPTION:
MODELS WITH ANALOGS & TEMPORARY RESTORATIONS
Models of the jaw, or copies of the impression model, can be 3D printed directly from the
planning software, with analog positions exactly in the planned implant positions. This enables
a temporary bridge to be made before the surgery, for immediate loading.
16
IMPLANTS
inadequate bone
Manufactured using 3D
Titanium Printer with Laser
Sintering technology
Higher
hydrophilic
Enhanced osseointegration
18 19
JAW RESTORATION
1 unique
biological surface
9 different kinds
of implants
4 platforms of implants
(double platform,
narrow, conical and
one piece)
22 | Implant drill protocol Implant drill protocol | 23
PROSTHETIC
DENTAL
IMPLANT DRILL PROTOCOL
IMPLANTS
RECOMMENDED STRAIGHT DRILL PROTOCOL RECOMMENDED CONICAL STOPPER DRILL PROTOCOL
Implant Bone
Diameter Type
Implant Bone
Soft Bone Diameter Type
Ø2.4 Hard Bone
Soft Bone
Ø2.4 Hard Bone
Soft Bone Optional
Ø3 Hard Bone
Soft Bone
Ø3 Hard Bone
Soft Bone Optional
Ø3.3 Hard Bone
Soft Bone
Soft Bone Ø3.3 Hard Bone
Ø3.5 Hard Bone
Soft Bone
Soft Bone
Optional
Ø3.5 Hard Bone
Ø3.75 Hard Bone
Optional
Soft Bone
Optional Ø3.75 Hard Bone
Soft Bone
Ø4.2 Hard Bone
Optional
Soft Bone
Optional
Ø4.2 Hard Bone
Soft Bone
Ø4.5 Hard Bone
Optional
Soft Bone
Optional Ø4.5 Hard Bone
Soft Bone
Ø5 Hard Bone
Optional
c
Soft Bone
Optional
Ø5 Hard Bone
Ø6 Soft Bone
Optional
Hard Bone c
16 mm _
13 mm _
11.5 mm _
10 mm _
8 mm _
6 mm _
Procedure recommended by AB Dental should not Procedure recommended by AB Dental should not
replace the dentist/surgeon’s judgment and experience. replace the dentist/surgeon’s judgment and experience.
Final drill color (for hard bone) should correspond to Final drill color (for hard bone) should correspond to
Implant’s Tube Cap color Implant’s Tube Cap color
24 | Bone level IMPLANT Bone level IMPLANT | 25
PROSTHETIC
DENTAL
I2 SCREW TYPE IMPLANT
IMPLANTS
PARTS INDEX - STANDARD PLATFORM
CAT D Tube top cap With/Without
Platform L (mm) colors Implant carrier
D no. (mm)
TMD TPD TD TD TD TD TD TD TD TD
L Drill Diameter (mm) Ø 1.9 Ø2 Ø 2.5 Ø 2.8 Ø 3.2 Ø 3.65 Ø 4.0 Ø 4.5 Ø 5.0 Ø 5.5
Drill Speed (RPM) 1200-1500 900-1200 800-1000 500-700 400-700 400-600 400-600 300-500 200-400 200-400
Biological surface
– the implant
undergoes Implant Bone
Diameter Type
special blasting
Triple threads with calcium Soft Bone
Ø3.5
start design phosphate for Hard Bone
with gentle, surface roughening Soft Bone
Optional
Ø5 Soft Bone
Hard Bone Optional
c
Optional
Ø6 Soft Bone
Optional
Hard Bone c
PROSTHETIC
DENTAL
I22 SCREW TYPE IMPLANT
IMPLANTS
PARTS INDEX - STANDARD PLATFORM
CAT D Tube top With/Without
Platform L (mm) cap colors Implant carrier
D no. (mm)
TMD TPD TD TD TD TD TD TD
Drill Diameter (mm) Ø 1.9 Ø2 Ø 2.5 Ø 2.8 Ø 3.2 Ø 3.65 Ø 4.0 Ø 4.5
Drill Speed (RPM) 1200-1500 900-1200 800-1000 500-700 400-700 400-600 400-600 300-500
L
Implant Bone
Biological surface Diameter Type
– Special calcium Optional
phosphate Ø3.75
Soft Bone
Optional
Hard Bone
sandblasting
Optional
followed by acid Ø4.2 Soft Bone
Optional
etching for surface Hard Bone
PACKAGE CONTENT AB Dental Implants can be provided in a package with or without an implant carrier. OPTIONAL DRILLS
Implant
Procedure recommended by AB Dental should not
replace the dentist/surgeon’s judgment and experience.
Final drill color (for hard bone) should correspond to
External Tube Internal Tube Components Internal Tube Components
Implant’s Tube Cap color
28 | Bone level IMPLANT Bone level IMPLANT | 29
PROSTHETIC
DENTAL
I5 CONICAL IMPLANT
IMPLANTS
CAT D Tube top cap With/Without
Platform L (mm)
Implant Bone
Equipped with a Diameter Type
switch platform Biological surface – Soft Bone
Ø3 Optional
for all diameters the implant undergoes Hard Bone
(excluding special blasting with Soft Bone
narrow platform) Ø3.3 Optional
Optional
Soft Bone
Ø4.2 Optional
Hard Bone
Optional
Soft Bone
Ø4.5 Optional
Hard Bone
Spiral, double, Optional
Ø5 Soft Bone
sharp and deep Hard Bone
Optional
c
threads Optional
Ø6 Soft Bone
Optional
Hard Bone c
OPTIONAL DRILLS
Clip carrier
T5
TDCS TDCS Final drills for cortical
3.75-4.2 5-6
dense bone as required.
Color coded tube
Cover screw
cap indicates the Implant
final dill color.
Implant
Procedure recommended by AB Dental should not
replace the dentist/surgeon’s judgment and experience.
External Tube Inside tube Components Inside tube Components Final drill color (for hard bone) should correspond to
Implant’s Tube Cap color
30 | Bone level IMPLANT Bone level IMPLANT | 31
PROSTHETIC
DENTAL
I55 CONICAL IMPLANT
IMPLANTS
PARTS INDEX - STANDARD PLATFORM
CAT D Tube top With/Without Im-
Platform L (mm)
no. (mm) cap colors plant carrier
L
Implant Bone
Diameter Type
Soft Bone
Unique combination A unique design for Ø3 Optional
Hard Bone
of aggressive and immediate loading
gentle threads giving maximum Implant Ø3.3
Soft Bone Optional
Hard Bone
increases the stability Optional
A narrow apex
Mark drill site
allowing implant TMD Marker drill bit
prime stability. Drill throughout entire implant’s length
Drill through cortical plate in case needed TPD Pilot drill bit
c Drill through cortical plate with Counter Sink drill in case needed TD Straight drill bit
PACKAGE CONTENT AB Dental Implants can be provided in a package with or without an implant carrier. OPTIONAL DRILLS
WITH CARRIER WITHOUT CARRIER
TDCS TDCS Final drills for cortical
3.75-4.2 5-6
dense bone as required.
Clip carrier
T5
Implant
Procedure recommended by AB Dental should not
replace the dentist/surgeon’s judgment and experience.
Final drill color (for hard bone) should correspond to
Outside tube Inside tube Components Inside tube Components
Implant’s Tube Cap color
32 | Bone level IMPLANT Bone level IMPLANT | 33
PROSTHETIC
DENTAL
I10 TRAPEZE IMPLANT
IMPLANTS
PARTS INDEX - STANDARD PLATFORM
CAT D Tube top With/Without
Platform L (mm)
no. (mm) cap colors Implant carrier
D
I10 3.75 Narrow 8, 10, 11.5, 13, 16 Both
TMD TPD TD TD TD TD TD TD
Drill Diameter (mm) Ø 1.9 Ø2 Ø 2.5 Ø 2.8 Ø 3.2 Ø 3.65 Ø 4.0 Ø 4.5
L Drill Speed (RPM) 1200-1500 900-1200 800-1000 500-700 400-700 400-600 400-600 300-500
PACKAGE CONTENT AB Dental Implants can be provided in a package with or without an implant carrier. OPTIONAL DRILLS
PROSTHETIC
DENTAL
I6 NARROW INTEGRAL IMPLANT
IMPLANTS
PARTS INDEX - STANDARD PLATFORM
CAT D L1 Tube top cap colors (indicating
L (mm) the final drill color)
no. (mm) (mm)
I6 2.4 11.5, 13, 16 7
I6 3 10, 11.5, 13, 16 7
I6 3.2 10, 11.5, 13, 16 7
L1
One piece RECOMMENDED DRILL PROTOCOL
conical, narrow,
integral implant TMD TPD TD TD TD
combined with Drill Diameter (mm) Ø 1.9 Ø2 Ø 2.5 Ø 2.8 Ø 3.2
abutment Drill Speed (RPM) 1200-1500 900-1200 800-1000 500-700 400-700
D
Designed
for narrow Implant Bone
alveolar ridges Diameter Type
with sufficient Soft Bone
depth and Ø2.4 Hard Bone
narrow
Soft Bone
interdental Ø3 Hard Bone
Optional
spaces
Soft Bone Optional
Ø3.2 Hard Bone
L
Mark drill site
Biological surface – TMD Marker drill bit
Drill throughout entire implant’s length
the implant undergoes
special blasting with Drill through cortical plate in case needed TPD Pilot drill bit
calcium phosphate for TD Straight drill bit
surface roughening
and enhanced
osseointegration
PROSTHETIC
DENTAL
I6b ONE PIECE BALL
IMPLANTS
ATTACHMENT IMPLANT
TMD TPD
Drill Diameter (mm) Ø 1.9 Ø2
Drill Speed (RPM) 1200-1500 900-1200
Implant Bone
Diameter Type
L Soft Bone
Ø2.4 Hard Bone
Biological surface –
the implant undergoes
special blasting with
calcium phosphate for
surface roughening
and enhanced
osseointegration
PROSTHETIC
DENTAL
I7 INTEGRAL IMPLANT
IMPLANTS
PARTS INDEX - STANDARD PLATFORM
CAT D L1 Tube top cap colors
L (mm)
no. (mm) (mm) (indicating the final drill color)
I7 3.75 8, 10, 11.5, 13, 16 11
I7 4.2 8, 10, 11.5, 13, 16 11
I7 5 8, 10, 11.5, 13 11
TMD TPD TD TD TD TD TD TD
The restoration
D is limited to Drill Diameter (mm) Ø 1.9 Ø2 Ø 2.5 Ø 2.8 Ø 3.2 Ø 3.65 Ø 4.0 Ø 4.5
cement retained Drill Speed (RPM) 1200-1500 900-1200 800-1000 500-700 400-700 400-600 400-600 300-500
concept
Implant Bone
Diameter Type
Optional
Soft Bone
Ø3.75 Optional
Hard Bone
Optional
Soft Bone
Ø4.2 Optional
Hard Bone
Optional
L Ø5 Soft Bone
Optional
Hard Bone c
Implant
Procedure recommended by AB Dental should not
replace the dentist/surgeon’s judgment and experience.
Final drill color (for hard bone) should correspond to
External Tube Internal Tube Components
Implant’s Tube Cap color
tools 14 kinds of drivers
19 kinds of kits
42 | drills drills | 43
16mm 16mm
6mm 6mm
TD-1.2 TD-1.5
COUNTER SINK TREPHINE
TMD-1.9 TDE
Ø 4.2 Ø 5.8 16mm
Marker Drill Bit Drill extension Ø 3.6 Ø 4.8 13mm
Ø 2.7 Ø 3.1 11.5mm
Bit 10mm
8mm
6mm
TDCS-3.75-4.2 TDCS-5-6
ID Ø 3.0 ID Ø 4.0 ID Ø 5.0
Counter Sink Counter Sink OD Ø 4.0 OD Ø 5.0 OD Ø 6.0
3 mm
T5-1.2,21 T5-1.2,26
T5-2,20 T5-2.4,20 3.75 mm
Contra Angle Driver for Abutment
T5-2,25 T5-2.4,25
Contra Angle Driver for implant –
(for implants without carrier) T15-3.75 T16 T17 T18-3.75,9 T22
T15-3 Implant position Tissue T18-3.75,18 Abutment
Disposal screw In collaboration with Punch Driver Implant removing Gripper
ABUTMENT DRIVERS removing Dr. Meir Aviram instrument kit
instrument kit
NEW
T1-1.2,9 T1-1.2,15
T2-1.2,9 T2-1.2,15 T4 T4-3
Ratchet Hex Driver for Abutment
Hand Hex Driver for Abutment - Retrieving Retrieving Screw
with friction Screw for narrow
platform
46 Surgical kits | 47
Width: 10cm
Length: 14.5cm
Height: 6.5cm
T3-2,18 TMD-1.9
Ratchet Hex Driver for Implant ø 1.9 Marker Drill Bit
TD-3.65
T5-2.4,25
Contra Angle Implant Driver ø 3.65 Drill Bit
T8 TD-4.0
ø 4.0 Drill Bit
Ratchet Wrench
or
T8c-10-40 TD-4.5
Ratchet-Torque Combination ø 4.5 Drill Bit
TP-23
Parallel Pin (x2)
48 | Surgical kits Surgical kits | 49
TD-2.5
TDCS-3.75-4.2
The kit is available in two options: ø 2.5 Drill Bit
Counter Sink
with Ratchet Wrench or with
Ratchet Torque TD-2.8
ø 2.8 Drill Bit TDCS-5-6
Counter Sink
TD-3.2
ø 3.2 Drill Bit T5-1.2,26
Contra Angle Driver for
TD-3.65
Abutment
ø 3.65 Drill Bit
T5-2,20
TD-4.0
Contra Angle Implant Driver
ø 4.0 Drill Bit
TD-4.5 T5-2.4,20
DEFAULT CONTENT ø 4.5 Drill Bit Contra Angle Implant Driver
DEFAULT CONTENT
TDG-3.65,17
TDG-2,17 Guide Drill Bit
Guide Drill Bit
TDG-2,21 TDG-3.65,21
Guide Drill Bit
Guide Drill Bit
TDG-2,25 TDG-3.65,25
Guide Drill Bit
Guide Drill Bit TH- 2.0
Handle - TH- 3.65
TDG-2,30 Diameter 2.0mm TDG-3.65,30 Handle - Drill Tool
Guide Drill Bit Guide Drill Bit Diameter 3.65mm
TDG-2.5,17
Guide Drill Bit T3G-2.4,30-G
Implant Driver
TDG-2.5,21
Guide Drill Bit
T3G-2.4,25-B
Implant Driver T3G-2.4
TDG-2.5,25 Driver for installing
Guide Drill Bit the implant through
ABGuide
TH- 2.5 Standard Platform
TDG-2.5,30 Handle - Drill Tool T3G-2.4,21-Y
Guide Drill Bit Diameter 2.5mm Implant Driver
T8c-10-40 TDG-2.8,30
FS-19 Guide Drill Bit
Fixation Screw Long Ratchet-Torque Combination
N T3G-2,25-B
Implant Driver T3G-2
TDG-3.2,17 Driver for installing
Guide Drill Bit the implant through
DEFAULT CONTENT ABGuide
Narrow Platform
TDG-3.2,21 N T3G-2,21-Y
TDG-1.5,19 Guide Drill Bit Implant Driver
Fixation Pin Drill Bit
TDG-3.2,25
T9
TP-1.5,31 Depth Gauge
Guide Drill Bit TH- 3.2
Fixation Pin (x3) Handle - Drill Tool N T3G-2,17-R
Diameter 3.2mm Implant Driver
TDG-3.2,30
Guide Drill Bit
TD-T17 T2-1.2,15
Ø4.35 Punch to cut
Hand Hex Driver for Abutment
gingival tissue
PROSTHETIC PARTS
10S of sizes,
diameters, degrees
etc. of solutions for
the convenience of
the dentist and the
technician’s time
60 prosthetic
saving and efficiency
solutions for tilted
implants
3.75 mm diameter
Internal Hex
Connection:
90˚cone
2.43mm Hexagon
58 | PROSTHETIC PARTS INDEX PROSTHETIC PARTS INDEX | 59
P2-P3S P2-P4S
Page 74 Page 75
P4S-
D1-6 D1-3.75,MA PEEK P3S P3SW P4S P4SW P3-3.75,TIT P3H-3.75,TIT
Page 64 Page 78 Page 67 Page 69 Page 69 Page 71 Page 71 Page 79 Page 79
P9HG P9HR
Page 72 Page 72
P0-3.75 D2 D2O
Page 60 Page 61 Page 61
P0N-3.75 P0-P14 D2N D2NO D2-P14 P14,SC P14-bT P14 P14-bR P14b
D1-P14 P16 P14-bts P14-bRs
Page 60 Page 87 Page 61 Page 61 Page 87 Page 87 Page 90 Page 87 Page 87 Page 87 Page 87 Page 91
Page 86 Page 91
Screw-retained
Restoration
P0-P64
D2-P12 D1-P64 D2-P64 P64,SC P64-bT P64 P64 P64b P64-bT-C
POW-3.75 Page 85
Page 82 Page 85 Page 85 Page 90 Page 85 Page 85 Page 84 Page 85 Page 91
Page 60
D1
L
aintains tissue
M Available for open tray
opening for - sharp edges & long
preparing the screw, and closed tray
L
site for placing - round edges & short
prosthetic device screw
Hexagon
impression
transfer
Suitable
for flat
connection
P0 P0N P0W D2 D2O D2N D2NO
Titanium Narrow Wide Impression Impression Narrow Narrow Impression
Healing Cap Titanium Titanium Transfer for Transfer for Impression Transfer for Open
Healing cap Healing Cap Closed Tray Open Tray Transfer for Tray
Closed Tray
P0-3.75,0.5 P0N-3.75,3 P0W-3.75,2
D2-3.75,9 D2O-3.75,9 D2N-3.75,9 D2NO-3.75,15
P0-3.75,2 P0N-3.75,4 P0W-3.75,3
D2-3.75,15 D2O-3.75,15
P0-3.75,3 P0N-3.75,5 P0W-3.75,4
D1 (mm) = 4.8 D1 (mm) = 4.8 D1 (mm) = 3.8 D1 (mm) = 3.8
P0-3.75,4 P0N-3.75,6 P0W-3.75,5 L (mm) = 9, 15 L (mm) = 9, 15 L (mm) = 9 L (mm) = 15
P0-3.75,5 P0N-3.75,7 P0W-3.75,6
P0-3.75,6
P0-3.75,7
15.5 mm
7.5 mm
D2 transfers are available with D2a or D2al screws.
A short screw for a closed tray and a long screw for an open tray.
D2a-3.75 D2al-3.75
62 | Impressions Impressions | 63
D1
D1
Available in
L 4 heights
(1-4mm)
Remains in the Suitable for parallel Enables quick and simple impression
impression throughout implants only taking as the closed tray technique,
the process while obtaining maximum precision
as the open tray technique
D3 D3N D4 D1
Implant Analog
Clip Transfer Narrow Clip Plastic Snap
Transfer Transfer with
Abutment
D3-3.75,9 D3N-3.75,9
D3-3.75,15 D3N-3.75,15
D4-3.75,1
PK-D2
D1 (mm) = 4.5 D1 (mm) = 3.5 D4-3.75,2 Plastic Transfer
L (mm) = 9,15 L (mm) = 9,15 D4-3.75,3
D4-3.75,4
D1 (mm) = 5.17 PK-P3-3.75
L (mm) = 1,2,3,4 Anatomic Anti – Rotation Abutment
1.8 mm
D1 ANALOG
Made of stainless
steel to allow
preparation of
Cement-Retained RESTORATION
STANDARD PLATFORM
laboratory models
L
Available in
3 diameters:
4, 5, 6
D1
cement-retained RESTORATION
P3S-PEEK TEMPORARY ANATOMIC P4S-PEEK TEMPORARY
ANTI-ROTATION ABUTMENT ANATOMIC ANGULAR ABUTMENT
High performance, D1
D1 biocompatible
thermoplastic polymer,
designed for medical Platform switching
device applications by design, allowing
perfect environment
for soft-tissue growth
and helps to prevent
bone resorption
L Available in 15° and 25°
L for angular restoration
LS LS
High performance,
Platform switching by design, biocompatible
allowing perfect environment for thermoplastic polymer,
soft-tissue growth and helps to designed for medical
prevent bone resorption device applications
1.8 mm 1.8 mm
All abutments include a short screw All abutments include a short screw
P4a-S P4a-S
68 | Straight ABUTMENT STRAIGHT ABUTMENT | 69
cement-retained RESTORATION
P3 ANTI-ROTATION P3S ANATOMIC
ABUTMENT ANTI-ROTATION ABUTMENT
D1 A straight Titanium Available in D1
abutment with hex narrow, wide &
anatomic options
1.8 mm 1.8 mm
All abutments include a short screw All abutments include a short screw
P4a-S P4a-S
70 | STRAIGHT ABUTMENT ANGULAR ABUTMENT | 71
cement-retained RESTORATION
P4 P4S ANATOMIC
ANGULAR ABUTMENT ANGULAR ABUTMENT
Available in
15° and 25° Available in
as a long 1-3mm heights
abutment
An angular abutment of
15°, 25°, 35° and 45° L
(35° and 45° were
L developed by AB Dental An anatomic angular
in collaboration with abutment of 15˚ and 25˚
Dr. Yehuda Gil)
Platform switching by LS
design, allowing perfect
environment for soft-
tissue growth Designed for The lower side
and helps to prevent restoration on is located in the
bone resorption tilted implants buccal part, ideal for
aesthetic outcome
D1 D1
D1 (mm) = 4.7 D1 (mm) = 4.7 D1 (mm) = 4.7 D1 (mm) = 3.75 D1 (mm) = 5 D1 (mm) = 4.7 D1 (mm) = 4.7 D1 (mm) = 5.7
15˚, 25˚, 35˚, 45˚ 15˚, 25˚ 15˚, 25˚ 15˚ 15˚ 25˚ 15˚ 25˚ 15˚
L (mm) 15˚, 25˚= 9 L (mm) = 9 L (mm) = 13.4 L (mm) = 9 L (mm) = 7 L (mm) = 7 L (mm) = 8
L (mm) = 10.75,
L (mm) 35˚, 45˚= 10, 12 LS (mm) = 1, 2, 3 LS (mm) = 1, 2, 3 LS (mm) = 4.2
11.1
cement-retained RESTORATION
P9 COMPOSED ABUTMENT P2 PLASTIC SLEEVE
Available in Gold or
Cobalt-Chrome alloy
Intended for casting with
no internal threading
Allows precise location
on the implant and
easy carving
L
L
Available with or
Platform switching by without hexagon:
design, allowing perfect
Composed environment for soft- • With hexagon to construct
Hex/non-Hex tissue growth and helps to on a single implant, or to
abutment prevent bone resorption set a crown or a bridge
LS onto the abutment
D1
D1
P2NH-3.75,15 P2N-3.75,15
P9HR-3.75,11 P9R-3.75,11 P9HG-3.75,11 P9G-3.75,11
D1 (mm) = 3.75 D1 (mm) = 3.75
D1 (mm) = 4.5 D1 (mm) = 4.5 D1 (mm) = 4.5 D1 (mm) = 4.5
L (mm) = 10 L (mm) = 10
L (mm) = 10 L (mm) = 10 L (mm) = 10 L (mm) = 10
LS (mm) = 1 LS (mm) = 1 LS (mm) = 1
1.8 mm 1.8 mm
cement-retained RESTORATION
P2-P3S STRAIGHT ANATOMIC P2-P4S ANGULAR ANATOMIC
PLASTIC SLEEVE PLASTIC SLEEVE
D1
Platform switching by
Platform switching by design, design, allowing perfect
allowing perfect environment for environment for soft-
soft-tissue growth and helps to tissue growth and helps to
prevent bone resorption LS
prevent bone resorption
LS
D1
1.8 mm 1.8 mm
All abutments include a short screw All abutments include a short screw
P4a-S P4a-S
76 | Individual ABUTMENT LAB PRODUCTS | 77
cement-retained RESTORATION
PK PROSTHETIC KIT
PK-3.75
PK-D1 PK-P2
Prosthetic Kit
Implant Analog Plastic Conical Sleeve (for crown)
PK-3.75,1
PK-3.75,2
PK-D2 PK-P2H
PK-3.75,3 Plastic Conical Sleeve (for bridge)
Plastic Transfer
PK-3.75,4
D1 (mm) = 5.17
PK-P0 PK-P3-3.75
L (mm) = 1,2,3,4
Healing Cap Anatomic Anti – Rotation Abutment
1.8 mm
CAD/CAM PRODUCTS
CAD/CAM SCAN ABUTMENTS CAD/CAM TITANIUM BASE
1 2 3 4 5 6 7
REVISIONS
REV. DESCRIPTION ECO DATE APPROVED
A
A A
C
C
CAD/CAM technology Made from CAD/CAM technology Titanium base
simplifies the work flow, PEEK - A high D simplifies the work flow, for cementing
ensuring accuracy, speed performance, ensuring accuracy, speed crowns and
and patient comfort biocompatible and patient comfort bridges made
thermoplastic Tolerances: The information contained in this drawing
by CAD/CAM
polymer Linear +- 0.05 is the sole property of AB Dental Devices.
D NOTES:
P3,TI P3H,TIT DRAWN
CHK'D
NAME
Ushakova G.
Betzalel M.
P3N,TIT
SIGNATURE DATE
09/10/18
SPESIFICATION: TITLE:
P3,TIT
Ti Base Abutment
H0.6mm Standard
D
REV. C
Abutment for Single
4. Milling and Hex surfaces oriented as shown. Abutment for Single Ti Base
WEIGHT:
0.10 Abutment
Ti-6AL-4V ELI
TiP3-3.75,TI
Base Abutment
Scan Narrow Long Digital Model Analog 1 Crown
2 3 4 for Bridges
5 6 for Bridges 7
Crown
Abutment Scan Abutment
P3-3.75,TI P3H-3.75,TIT P3N-3.75,0.6,TIT P3-3.75,TIT
Ti Base Slim Ti Base Wide Ti Base Rotational Slim Ti Base Rotational Wide
P3-3.75,SC P3L-3.75,SC H0.6mm H0.7mm H0.6mm NEW H0.8mm
D1-3.75,MA NEW Standard Platform Standard Platform Standard Platform Standard Platform
Scan Abutment Long Scan Implant Model
Standard Abutment Anlaog Standard Platform P3-3.75,2,TI P3N-3.75,2,TIT
Platform Standard Platform Ti Base Slim NEW Ti Base Rotational Slim
H2mm H2mm NEW
D (mm) = 4.5 D (mm) = 4.2 D (mm) = 3.8 Standard Platform Standard Platform
Model analog for D (mm) = 4.3 D (mm) = 5.2 D (mm) = 4.3 D (mm) = 5.2
digital printed model L (mm) = 4 L (mm) = 4.5 L (mm) = 4.1 L (mm) = 4.5
manufacturing
LS (mm)=0.6, 2, 3 L S (mm) = 0.7 L S (mm) = 0.6, 2, 3 L S (mm) = 0.8
1.8 mm
Scan abutments includes a short screw
P4a-S for standard platform. Two-Piece design for
Model Analog includes screw. precise positioning
P4a-S
1.8 mm
cement-retained RESTORATION
Screw-retained RESTORATION
STANDARD PLATFORM
82 | Straight ABUTMENT Straight ABUTMENT | 83
PROSTHETIC PARTSRESTORATION
screw-retained
ISSU
P12 FLAT ED P
ATEN
T!
CONNECTION ABUTMENT
D1 Temporary Abutment
D2-P12-3.75,15 D2N-P12-3.75,15
D1 (mm) = 4.5 D1 (mm) = 3.75 D1 (mm) = 4.8 D1 (mm) = 3.75
L (mm) = 5 L (mm) = 5 L (mm) = 9, 15 L (mm) = 9, 15
In case of a non-double platform implant, the P12C adaptor enables the use of a flat connection abutment.
PROSTHETIC PARTSRESTORATION
screw-retained
P64 MULTI-UNIT
D1 The impression-taking
NEW
The D4-P64 set contains : PK-D2 Transfer (3 units),
P64 angular adaptor includes P64e screw. Special P64 Adapter and P14a screw.
P64 straight adaptor is provided with P14Ca Carrier 11.5 mm
and P14a screw. 1.8 mm 1.8 mm
1.8 mm
P64 angular adaptor is provided with P64c Carrier. All sleeves include a P14a screw.
P14C-aL is an optional long Carrier. D2-P64 transfer includes D2-P14a screw.
P14a P64e P64c P14Ca P14C-aL P14a D2-P14a
86 | STRAIGHT/ANGULAR ABUTMENT STRAIGHT/ANGULAR ABUTMENT | 87
PROSTHETIC PARTSRESTORATION
screw-retained
P16/P14 STRAIGHT/MULTI-UNIT
ADAPTOR
The adaptor (base & cone) Platform switching by
D1 enables restoration on design, allowing perfect
NEW
11.5 mm
1.8 mm
1.8 mm
All sleeves include P14a screw.
P14/P16 adaptors include P14a screw. D2-P14 transfer includes D2-P14a screw.
P14a P14C-aL P14a D2-P14a
88 | STRaight ABUTMENT STRaight ABUTMENT | 89
PROSTHETIC PARTSRESTORATION
screw-retained
P7 ANTI-ROTATION
AESTHETIC ABUTMENT
cad/cam products
STANDARD PLATFORM
Suitable for
restorations on a
single implant or a
screwed bridge on
L non-parallel implants
Platform switching by
design, allowing perfect
environment for soft-
tissue growth and helps to An abutment with
prevent bone resorption hex on both sides
P7 P7b P7b-H
Aesthetic Plastic sleeve Plastic sleeve
abutment without hex with hex
P7-3.75,1 P7b P7b-H
P7-3.75,2
P7-3.75,3
D1 (mm) = 4.7 D1 (mm) = 6 D1 (mm) = 4.7
L (mm) = 1, 2, 3 L (mm) = 8.5 L (mm) = 12
2 mm 2 mm
All abutments include a P7-a screw 2 mm
according to the abutment heights 11 mm 12 mm 13 mm
respectively. P7 includes a P7b plastic
sleeve without hex.
P7a-1 P7a-2 P7a-3
90 | CAD/CAM PRODUCTS CAD/CAM PRODUCTS | 91
PROSTHETIC PARTSRESTORATION
screw-retained
CAD/CAM SCAN BODIES 1 CAD/CAM TITANIUM SLEEVES
2 3 4 5
REVISIONS
6 7
REV. DESCRIPTION ECO DATE APPROVED
1 2 3 4 5 6 7 A
REVISIONS
REV. DESCRIPTION ECO DATE APPROVED
A A A
A A A
These 3D libraries enable AB Dental These 3D libraries enable AB Dental
precise computerized products have precise computerized products have
planning of the future been added to planning of the future been added to
C
A
C
Made from D
Titanium base
Tolerances: The information contained in this drawing
Linear +- 0.05
D DRAWN
NAME
REV.
TECAPEEK MT CLASSIX WHITE
DWG NO.
C
and patient comfort
thermoplastic by CAD/CAM
WEIGHT:
4. Milling and Hex surfaces oriented as shown. 0.15 Tolerances: The information contained in this drawing
Linear +- 0.05 is the sole property of AB Dental Devices.
1 2 3 4 5 6 7 Angular +- 1* Any reproduction in part or as a whole without
A.B.Dental Devices LTD.
polymer Dimensions are
in millimeters
the written permission
of AB Dental Devices is prohibited.
D
NAME SIGNATURE DATE SPESIFICATION: TITLE:
P64 Ti Conical
D
P64 P64 P14/P16
DRAWN Ushakova G. 09/10/18
* Includes screw
D (mm) = 4.9 D (mm) = 4.9 D (mm) = 4.4
L (mm) = 5.5 L (mm) = 5.55 L (mm) = 5.5
1.8 mm
Scan Body includes a short screw P14a. Two-Piece design for
Model Analog include screw. precise positioning
P14a
1.8 mm
Overdenture RESTORATION
STANDARD PLATFORM
92
94 | Straight ABUTMENT Straight ABUTMENT | 95
Overdenture Restoration
P5 BALL ATTACHMENT P25 AB LOC ATTACHMENT
2.5mm
Platform switching by
Silicon caps are available The reduced height enables design, allowing perfect
in three degrees of the dentist to place an environment for soft-
hardness, 1-3, from the overdenture even in cases of tissue growth and helps to
hardest to the softest D reduced interocclusal space prevent bone resorption
D1
P25-3.75,5
P25-a,b/10
D1 (mm) = 3.9 D1 (mm) =4.6
L (mm) = 0.2,1,2,3,4,5 L (mm) =1.7
Overdenture Restoration
ISSU
P5-20 ANGULAR ED P
ATEN P5\P25 ANGULAR BASE
T!
BALL ATTACHMENT 20° ATTACHMENT
2.5 mm Angular adaptors bases with a combination of ball attachments
Excellent solution for non-
Multi-optional angular parallel implants, even at and AB LOC attachments
ball attachment, extreme angles, for accurate
made from a single
piece, designed to
joints on overdenture implants P14base-17
P14base-30 P5-P14 P25-P14
connect a denture on
tilted implants Base for Base for Ball for AB LOC for
angular angular angular Angular Adaptor
L
adaptor adaptor adaptor
Enables adjustment of Issued Patent
the angle at which the by A.B. Dental
implant is positioned
P14base,17-1 P14base,30-1 P5-P14,1 P25-P14,1
P5-20 P5b
Angular ball Silicon cap
attachment 20˚
P5-3.75,20-1 P5b-1 (Hard, grey color)
1.8 mm
P5-3.75,20-2 P5b-2 (Medium, transparent color)
P5-3.75,20-3 P5b-3 (Soft, pink color) P14 base is available with P14e screw.
P14e
P5-3.75,20-4 P5b-4 (For lab, black color)
P5-3.75,20-5
P5-3.75,20-6
D1 (mm) =4 D1 (mm) =4
20 0
L (mm) =2.5
L (mm) =1, 2, 3, 4, 5, 6
Each P5-20 abutment include it’s own P5-20a screw (per it’s height) 7 mm
and a silicon cap
P5-20a
P5-20 attachment is also available as a set including metal and silicon caps
P5-20 P5a P5b P5d
98 99
cement-retained RESTORATION
NARROW PLATFORM
3 mm Diameter
Mini Conical
Connection:
60˚cone
2mm Hexagon
100 | PROSTHETIC PARTS INDEX PROSTHETIC PARTS INDEX | 101
D1-3
P3L-3,SC
Restoration
P0-P14 D1-P14 D2-P14 P14,SC P14-bT P16 P14 P14-bR P14b P14-bts P14-bRs
Page 119 Page 119 Page 119 Page 90 Page 119 Page 118 Page 119 Page 119 Page 119 Page 91 Page 91
P0-P64
D1-P64 D2-P64 P64,SC P64-bT P64 P64 P64b P64-bT-C
Page 119
Page 121 Page 121 Page 90 Page 121 Page 120 Page 121 Page 121 Page 91
D4
Page 105
D1
Polished Titanium
surface for excellent
tissue acceptance
L
Available for open
L tray - (sharp edges
Maintain tissue and long screw),
opening when and for closed tray
preparing the (round edges and
site for prosthetic short screw)
Narrow platform
device
- 3mm diameter
P0 D2 D2O
Titanium Impression Impression
healing cap transfer for transfer for
closed tray open tray
P0-3,5
P0-3,7
D1 (mm) = 4.2
L (mm) = 2, 3, 4, 5, 7
19 mm
8 mm
The set is
Impression designed for
L taking with a multiple uses
click
Narrow platform -
3mm diameter
Available in
L 3 heights
Remains in the
(1-3mm)
impression throughout
the process
Suitable for parallel
implants only Enables quick and simple impression
taking as the closed tray technique,
while obtaining maximum precision
as the open tray technique
D1
D4-3,3
D1 (mm) = 5.17
L (mm) = 1,2,3
PK-P3-3 NEW
2 mm
D1 ANALOG
Made of Stainless
Steel to allow
preparation of
Cement-Retained RESTORATION
NARROW PLATFORM
laboratory models
Narrow
L platform
- 3mm
diameter
D1
D1-3
Analog
D1-3
D1 (mm) = 4
L (mm) = 12
108 | temporary abutment Straight ABUTMENT | 109
L
L
Narrow platform -
LS 3mm diameter
A straight Titanium
abutment with hex
Narrow platform - 3mm
diameter
2 mm 2 mm
All abutments include a short screw All abutments include a short screw
P3a-3 P3a-3
110 | ANGULAR ABUTMENT INDIVIDUAL abutment | 111
A A
Designed for
restoration on Intended for
tilted implants casting with no
B L Available with or without internal threading
B
hexagon:
D
NAME SIGNATURE DATE SPESIFICATION: TITLE:
PROJ. METHOD:
Rounded
SCALE:
10:1 MATERIAL: DWG NO.
1 2 3 4 5 6 7
D1 (mm) = 4.2 D1 (mm) = 4.5 for 15˚ D1 (mm) = 4.1 L (mm) = 7.15 L (mm) = 7.15
2 mm 2 mm
All abutments include a short screw All abutments include a short screw.
P3a-3 P3a-3
112 | Straight ABUTMENT STRaight ABUTMENT 113
|
cad/cam products
Perfect solution for impression and
transfer techniques, both for a single
crown and bridge restoration
PK-D1 PK-P2
Implant Analog Plastic Conical Sleeve
PK-3
Prosthetic Kit
PK-3,1
PK-D2 PK-P2H
Plastic Transfer Plastic Conical Sleeve
PK-3,2
PK-3,3
PK-P0 PK-P3-3 NEW
D1 (mm) = 5.17
Healing Cap
L (mm) = 1,2,3 Anatomic Anti – Rotation Abutment
Narrow Platform
2 mm
A A A
LS
The scanning information Also for intra- The scanning information
is used to produce precise oral scanning is used to produce precise
restoration on AB implants restoration on AB implants
using CAD/CAM C using CAD/CAM C
D
A
CAD/CAM technology Made from CAD/CAM technology The information contained in this drawing
Titanium base
PEEK - A high
Tolerances:
simplifies the work flow, simplifies the work flow, A.B.Dental Devices LTD.
Linear +- 0.05 is the sole property of AB Dental Devices.
Angular +- 1* Any reproduction in part or as a whole without
Dimensions are the written permission
for cementing
ensuring accuracy, speed performance, in millimeters
D Ti Base Abutment
biocompatible bridges made
Ushakova G. 09/10/18
1
P3,TI 2 3
P3H,TIT 4
P3N,TIT 5 6
P3,TIT 7
P3,SC P3L,SC D1-3,MA Slim Ti Base Wide Ti Base Slim Rotational Wide Rotational
Abutment for Abutment for Single Ti Base Abutment Ti Base Abutment
Scan Narrow Long Digital Model Analog Single Crown for Bridges for Bridges
Crown
Abutment Scan Abutment
P3-3,TI P3H-3,TIT P3N-3,0.6,TIT NEW
P3-3,TIT
Ti Base Slim Ti Base Wide Ti Base Rotational Slim Ti Base Rotational Wide
P3L-3,SC D1-3,MA H0.8mm H0.8mm H0.6mm H0.8mm
P3-3,SC NEW Narrow Platform Narrow Platform Narrow Platform Narrow Platform
Long Scan Implant Model
Scan Abutment P3-3,2,TI P3N-3,2,TIT
Abutment Analog Narrow Platform NEW NEW
Narrow Platform
Narrow Platform Ti Base Slim Ti Base Rotational Slim
H2mm H2mm
D (mm) = 4.5 D (mm) = 3.7 D (mm) = 3.5 Narrow Platform Narrow Platform
Model analog for D (mm) = 4.3 D (mm) = 5.2 D (mm) = 4.1 D (mm) = 5.2
digital printed model L (mm) = 4 L (mm) = 4.5 L (mm) = 4.1 L (mm) = 4.5
manufacturing
LSmm=0.8, 2, 3 L S(mm) = 0.8 L S(mm) = 0.6, 2, 3 L S(mm) = 0.8
cement-retained RESTORATION
Screw-retained RESTORATION
NARROW PLATFORM
118 | STRAIGHT/ANGULAR ABUTMENT STRAIGHT/ANGULAR ABUTMENT | 119
NEW
11.5 mm
1.8 mm
1.8 mm
All sleeves include P14a screw.
P14/P16 adaptors include P14a screw. D2-P14 transfer includes D2-P14a screw.
P14a P14C-aL P14a D2-P14a
120 | STRAIGHT/ANGULAR ABUTMENT STRAIGHT/ANGULAR ABUTMENT | 121
Overdenture RESTORATION
NARROW PLATFORM
122
SCREW-retained RESTORATION - NARROW PLATFORM
124 | Straight ABUTMENT Straight ABUTMENT | 125
P5-20 P5b
Angular Ball Silicon cap
attachment 20˚ 1.8 mm
P5-3,20-1.5 P5b-1 (hard, grey color) P14 base is available with P14e screw.
P14e-3
P5-3,20-3 P5b-2 (medium, transparent color)
1.5 mm
7 mm
P5-20 attachment Includes P5-20a screw and silicon cap.
P5-20a
P5-20 attachment is also availble as a set including metal and silicon caps.
P5-20 P5a P5b P5d
PROSTHETIC PARTSRESTORATION
screw-retained INDEX - STANDARD PLATFORM
& ACCESSORIES
129
BONE GRAFTS
128
130 | bone graft & membrane bone graft & membrane | 131
HUMAN BONE
Bone Grafts and Tissues from Human Source EPIFLEX®
Matrix of human skin allograft – cell-free. A Gold Standard product for
soft tissue supplement in Europe and the United States.
CORTIFLEX® – DEMINERALISIERTER CORTICAL SPAN (flexible after Rehydration)
EPIFLEX® HUMAN SKIN, CELL-FREE, FREEZE DRIED
CORTIFLEX® – Demineralized Cortical Strip (flexible after rehydration)
Available sizes:
Cat. No. Description Size
AB 7545 | Cortical Strut 15 × 30 mm
AB 7546 | Cortical Strut 15 × 60 mm AB4200 EPIFLEX® Thickness 0.3mm-0.8mm 20x10mm
AB 7547 | Cortical Strut 15 × 120 mm
AB 7548 | Cortical Strut 20 × 25 mm AB4300 EPIFLEX® Thickness 0.3mm-0.8mm 30x10mm
AB5003 Cortical Cancellous Granules, 0.212-0.85 mm 3cc DBM PUTTY 0.212-0.85 mm 0.5cc
AB3005
AB5005 Cortical Cancellous Granules, 0.212-0.85 mm 5cc
AB3010 DBM PUTTY 0.212-0.85 mm 1cc
AB5101 Cortical Cancellous Granules, 1-2 mm 1cc
AB3025 DBM PUTTY 0.212-0.85 mm 2.5cc
AB5103 Cortical Cancellous Granules, 1-2 mm 3cc
AB5105 Cortical Cancellous Granules, 1-2 mm 5cc
BIOFILL-B is made from 100% cancellous bone without any cortical portion.
BIOFILL-S is highly bioactive, stimulating the proliferation and
Innovative pulverizing technique allows multiparous structure, maximizing blood
differentiation of osteoblasts, allowing a total replacement by new vital bone during
vessel ingrowth.
the healing process, within 1-6 months.
Average BIOFILL-B pore size is more than three times of other world leading product.
Osteoconductive surface.
Its osteoconductive structure combined with its high hydrophilic promotes the
Octacalcium phosphate crystal resulting fast bone formation.
suffusion of biological fluids.
Store at the temperature range 4-30°c.
Included in delivery:
• MD 11 control unit 20 : 1 LED Contra Angle
• Electronic Vario pedal
• Electronic Motor New A.B. Dental MD 11 Motor System for Implantology with sophisticated motor control,
• Sterile tube set, 2 m
• Clip set for tube set mount for smooth and precise power delivery - any speed range.
• Stand for irrigation fluid
• Handpiece cradle Motor speed range of 300 – 40’000 rpm.
• User Manual MD 11 in
5 languages on CD-ROM
70 Ncm of maximum torque at 20:1 Contra Angle with graphical, real time torque control
Optional:
on display - (with or without LED - optional) with internal/external cooling system
• Contra Angle 20:1 LED Sturdy, high quality finish.
• Contra Angle 20:1
Integrated pump system for cooling to prevent tissue damage.
The new A.B. Dental MD 11 Motor System, is developed with the intention to put extra smoothness
into your hands. electronic motor and sophisticated motor control are key players in this product.
20:1 CONTRA 20:1 LED CONTRA ANGLE This reflects new design with smooth edges for easy cleaning and a display that gives you all the
ANGLE information at a glance. Single function keys with haptic and audible feedback guarantee for accurate
20:1 Contra Angle
device setup.
2028 AB MD 11, brushless single motor system, 40,000 rpm consists of:
New A.B. Dental MD 11 Motor System for Implantology with sophisticated motor control, 1 x Control unit MD 11 (3335) with 1 micromotor socket, irrigation pump on the top surface of
for smooth and precise power delivery - any speed range. the housing, socket for Vario-pedal
Motor speed range of 300 – 40’000 rpm. 1 x Contra-angle 20:1 (with or without LED optional) with internal/external cooling system (5052)
1 x Electronic motor 21, 40,000 rpm, with cable 2 m, autoclaveable, metal plug (2097)
70 Ncm of maximum torque at 20:1 Contra Angle with graphical, real time torque control
1 x Vario-foot control IP 68 (1866), electronic, suitable for operating theatre
on display - (with or without LED - optional) with internal/external cooling system
1 x Single tubing set (1706), disposable, sterile, 2 m
Sturdy, high quality finish. 1 x Bottle holder (1770)
Integrated pump system for cooling to prevent tissue damage. 2 x Spray nozzle attachment for NOU-CLEAN (1942 / 1958)
1 x Cooling fluid flask NaCl 0.9 %, 1lt (1696)
136 | accessories 137