APP-353-I

DOCUMENT CHANGE PROPOSAL


Document Type TRAINING MODULE Request Status Complete Review
Document Level LEVEL 3 DCP Number DCP-09-24738952
Document Number TM-G60 Effectivity Date 10/15/2009 10:51:47
AM
Document Title CONFORMAL COATING AND ADHESIVE APPLICATION

AFFECTED AREAS

ACDC-Custom New Products In-House Assy Finance


ACDC-ASP Quality Assurance AC-DC Materials PSG
DCDC/EC Product Eng'g MSD/IE and System Eng'g IQC/SQE
Quality Assurance DC-DC Admin Test Engineering
Traffic MIS Process Engineering
Purchasing HR

PROPOSED CHANGES(Pls identify clearly)


New release
OTHER DOCUMENTS AFFECTED BY THIS CHANGE( to be identified by the originator )
none

Originator : Margie Salgado/Cavite/PH/Astec

Reviewed By : Alvin Hernandez/Cavite/PH/Astec


Immediate Superior
Reviewed on 10/14/2009 3:21:39 PM

APPROVERS

Allan Manio/Cavite/PH/Astec
QS-Manager
Approved on 10/15/2009 10:51:47 AM

Maricel Rascano/Cavite/PH/Astec
Doccon Personnel
Notified on 10/15/2009 10:51:47 AM

Edit History

Author: Margie Salgado/Cavite/PH/Astec Date Created: 14 Oct 2009 07:56 AM

Modified by Date modified Status

Margie Salgado/Cavite/PH/Astec 10/14/2009 8:56:13 AM Submitted For Review and Approval


Alvin Hernandez/Cavite/PH/Astec 10/14/2009 3:21:39 PM Reviewed Document
Allan Manio/Cavite/PH/Astec 10/15/2009 10:51:47 AM Document Approved

Note : You need to review your procedure on or before 10/15/2010


Training Module No. : TM-G60 Effective Date : 11/04/2009

Revision No. : 00 Page 01 of 13

Revision History

Revision# Reason for Change Revised by Date

00 New Release Jonathan Enriquez 11/04/2009

For latest update please refer to


ASTEC POWER PHILS, INC.
DOCUMENT CONTROL
This document contains
CONFIDENTIAL information and/or
TRADE SECRETS of ASTEC POWER
PHILIPPINES, INC.
Unauthorized use or disclosure is
STRICTLY PROHIBITED

DATE: 11/04/2009

Emerson Network Power Confidential


Training Module No. : TM-G60 Effective Date : 11/04/2009
Revision No. : 00 Page 02 of 13

Title : CONFORMAL COATING AND


ADHESIVE APPLICATION

Prepared by : Jonathan Enriquez Approved by : Allan Manio

Reviewed by : Alvin Hernandez

Emerson Network Power Confidential


Training Module No. : TM-G60
Revision No. : 00 Page 03 of 13

Summary :

Section Topic Trainer Time

1.0 Definition of Terms Process Eng'r. 10 mins.


2.0 Work Instruction Sheet(WIS) Process Eng'r. 10 mins.
3.0 Understanding WIS Process Eng'r. 20 mins.
4.0 Criteria of Acceptance Process Eng'r. 10 mins.
5.0 Definition of Terms(Conformal) Process Eng'r. 10 mins.
6.0 Conformal Coating Steps Process Eng'r. 10 mins.
7.0 Method of Application Process Eng'r. 20 mins.
8.0 Conformal Coating Requirement Process Eng'r. 10 mins.
9.0 Housekeeping & Other Process Eng'r. 10 mins.
Basic Rules

Emerson Network Power Confidential


Training Module No. : TM-G60
Revision No. : 00 Page 04 of 13

Section 1.0 Definition of Terms

Sonybond is a one component sealant/adhesive which


cures to form a tough, permanently flexible rubber to make a
rigid bond between components and PCB Assembly.

It is used to ensure that the components are anchored to


the PCB assembly during harsh environment the power supply is
to undergo.

Emerson Network Power Confidential


Training Module No. : TM-G60
Revision No. : 00 Page 05 of 13
PCB Part number

Model

Parts List

Procedure Tools, Jigs &


Fixtures

Workplace
Layout

Revision History

Illustration

Emerson Network Power Confidential


Training Module No. : TM-G60
Revision No. : 00 Page 06 of 13
Section 3.0 Understanding WIS

Model : Assembly unit which being built


PCB P/N: Latest revision of PCB used
Parts List: Latest parts used based on Bill of Material
Tools, jigs &
Fixtures : List of tools, jigs, fixtures and machine used to
perform task
Workplace
Layout : Desired layout of sonybond area

Revision
History : List of changes from initial release up to latest

Illustration: Sample picture of the final form of the assembly


Procedure: Step by step method to accomplish the final
form of the assembly

Emerson Network Power Confidential


Training Module No. : TM-G60
Revision No. : 00 Page 07 of 13

Section 4.0 Criteria of Acceptance

4.1 Adhesive should be flow from the half(50%) of the component


down to the PCB component side to anchor it permanently.

4.2 Refer to the Work Instruction Sheet(WIS) for the correct location
of the PCB assembly where and what type of adhesive should be used.

Emerson Network Power Confidential


Training Module No. : TM-G60
Revision No. : 00 Page 08 of 13

Section 5.0 Definition of Terms


Conformal coating is a protective non conductive dielectric
layer that is applied onto the printed circuit board assembly to
protect the electronic assembly from damage due to
contamination, salt spray, moisture, fungus, dust and corrosion
caused by harsh or extreme environments.

Section 6.0 Conformal Coating Step

a) Board is cleaned.
b) Protected areas like terminal pins, connectors are masked off or
removed.
c) Coating is applied using any suitable method on both sides of the PCB
and its edges.
d) Coating is cured using oven according to the coating type.
e) Masking is removed and any removed parts are reassembled.
f) Board undergoes full production testing to ensure
functionality of board is not affected by the process.
Emerson Network Power Confidential
Training Module No. : TM-G60
Revision No. : 00 Page 09 of 13

Section 7.0 Method of Application

7.1 DIP METHOD: This method, in which the masked


assembly is immersed in a tank of liquid coating material and withdrawn,
ensures uniform coverage and predictable, repeatable film thickness.The
assembly should be immersed slowly to allow the coating material to
displace the air surrounding components, remain immersed until bubbling
has ceased, and then withdrawn.

Emerson Network Power Confidential


Training Module No. : TM-G60
Revision No. : 00 Page 10 of 13

7.2 SPRAY METHOD: Spraying, manual or robotic, is the most


popular and the fastest method for applying conformal coatings. With the proper
combination of solvent dilution, nozzle pressure, and pattern, reliable and consistent
results are obtainable

Emerson Network Power Confidential


Training Module No. : TM-G60
Revision No. : 00 Page 11 of 13

7.3 BRUSH METHOD: Brushing is the least efficient application


method because of difficulty in achieving uniform coverage (hence, uniform coating
thickness) and controlling bubbling. While this operator dependent method is not
practical for high-volume production, it is suited to short run, prototype and touch-up
after repair/rework. Particular attention should be paid to the underside of
components and lead wires. Care must be exercised to avoid deposit of brush fibers
in the coating.

Emerson Network Power Confidential


Training Module No. : TM-G60
Revision No. : 00 Page 12 of 13
Section 8.0 Conformal coating Requirement

8.1 UV Light: To check the presence or absence of conformal


coating film onto the PCB assembly.
8.2 Exhaust: To vacuum the smell of conformal coating
chemical away from the work area.
8.3 PPE’s : Personal Protective Equipment such as
facemask,goggles, aprons and gloves to protect the operator from
abrasive chemicals

Emerson Network Power Confidential


Training Module No. : TM-G60
Revision No. : 00 Page 13 of 13

Section 9.0 Housekeeping & Other Guidelines

9.1 Conduct housekeeping regularly.

9.2 Ensure the presence of tools/equipment as per WIS.

9.3 Check the presence of Work Instruction Sheet(WIS) prior


operation.If in doubt, ask the help of your superiors and/or the
support group.

9.4 Check if tools, jigs & equipment are within the prescribed
preventive maintenance schedule or calibration
schedule.

Emerson Network Power Confidential