Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Chemical Process Control - - Unit 8 - Week 7 https://onlinecourses-archive.nptel.ac.in/noc19...

reviewer4@nptel.iitm.ac.in ▼

Courses » Chemical Process Control Announcements Course Ask a Question Progress FAQ

Unit 8 - Week 7
Register for
Certification exam Assignment 7
The due date for submitting this assignment has passed.
Course As per our records you have not submitted this Due on 2019-04-17, 23:59 IST.
outline
assignment.

How to access 1) In cascade control, tuning of primary loop depends on the parameters of the secondary 1 point
the portal controller.

Week 1 True

False
Week 2
No, the answer is incorrect.
Week 3 Score: 0
Accepted Answers:
Week 4
True
Week 5 2) Consider that a reactor carrying out an exothermic reaction is cooled by circulating water in 1 point
the jacket. The inlet temperature of the reactor feed is the key disturbance. A young process engineer
Week 6 recommended the use of cascade control to speed up the response. Has he made a correct
recommendation?
Week 7

Lecture 38 : yes
Cascade no
control
insufficient information
Lecture 39 :
Split range No, the answer is incorrect.
control and Score: 0
override control
Accepted Answers:
Lecture 40 : no
Auctioneering,
ratio and 3) A split range configuration implementation for sump level control in a distillation column is 1 point
inreferential shown below. If the controller output is 12 mA, what are the positions of the product and drain valves?
control

Lecture 41 :
Openloop
control and
Internal model
product valve fully open, drain valve fully closed
control
product valve fully closed, drain valve fully open
Lecture 42 :
© 2014 NPTEL - Privacy & Terms - Honor Code - FAQs -
Dynamic Matrix product valve 80% open, drain valve 20% open
A project
andofModel In association with
predictive product valve 20% open, drain valve 80% open
control
No, the answer is incorrect.
Weekly Score: 0 Funded by
Feedback

1 of 4 Thursday 20 June 2019 06:16 PM


Chemical Process Control - - Unit 8 - Week 7 https://onlinecourses-archive.nptel.ac.in/noc19...

Download Accepted Answers:


Powered by
Videos product valve 80% open, drain valve 20% open

Quiz : 4) A liquid product is withdrawn from a tank for feeling to a reactor at a desired flowrate value. 1 point
Assignment 7 In the rare event of tank level falling below 10%, the level control takes precedence and outlet flow is
Assignment 7 restricted irrespective of the flowrate requirement. The traditional advanced control strategy used here
solutions is

Week 8 cascade control

TEXT split range control


TRANSCRIPTS override control

Interaction inferential control


Session
No, the answer is incorrect.
Score: 0
Accepted Answers:
override control

5) A circulating chilled water system is used to cool a process stream from 90F to 70F. The outlet
temperature of the process stream is regulated by manipulating the flow rate of the chilled water. The
flowrate of the chilled water should not fall below 500 gpm. This is accomplished by installing an
override control architecture. In such a configuration, we would need a ____ selector switch.

Hint

No, the answer is incorrect.


Score: 0
Accepted Answers:
(Type: String) high

1 point

6) While using inferential control in distillation column, composition control is replaced by temperature
control. This control system is effective if the system additionally has a _____ controller to ensure
validity of temperature-composition relationship.

Hint

No, the answer is incorrect.


Score: 0
Accepted Answers:
(Type: String) pressure

1 point

7) Consider a process with transfer function 1−s 1 point


.It is decided to implement open-loop
s2 +4s+3
model-based control for this process. The corresponding controller transfer function will be

s2 + 4s + 3

s2 +4s+3
(λs+1)2

2 of 4 Thursday 20 June 2019 06:16 PM


Chemical Process Control - - Unit 8 - Week 7 https://onlinecourses-archive.nptel.ac.in/noc19...

s2 +4s+3
(λs+1)(1−s)

s2 +4s+3
(1−s)

No, the answer is incorrect.


Score: 0
Accepted Answers:
s2 +4s+3
(λs+1)2

8) A process with transfer function 2 1 point


is to be controlled by using a PID
(s+1)(s+2)(s+3)
controller. If IMC-based PID controller with λ of 0.1 has to be implemented, the corresponding controller
parameters (KC, τI, τD) will be
(Hint: Use Skogested’s half rule)

(2.27, 5.00, 0.80)

(5.38, 2.45, 0.11)

(7.83, 1.98, 0.55)

(11.81, 1.54, 0.24)

No, the answer is incorrect.


Score: 0
Accepted Answers:
(11.81, 1.54, 0.24)

9) In DMC, if control input cost (cost associated with the use of manipulated variable) is high, 1 point
one should use

f=0

f=1

f >> 1

f = −1
No, the answer is incorrect.
Score: 0
Accepted Answers:
f >> 1
10)MPC can be used if there are more number of controlled variables than the manipulated 1 point
inputs.

True

False

No, the answer is incorrect.


Score: 0
Accepted Answers:
True

Previous Page End

3 of 4 Thursday 20 June 2019 06:16 PM


Chemical Process Control - - Unit 8 - Week 7 https://onlinecourses-archive.nptel.ac.in/noc19...

4 of 4 Thursday 20 June 2019 06:16 PM

You might also like