Possible Causes
https://www1.prodemand.com/Print/Index?content=tabs&module=true&tab=true&terms=true&ymms=false&selectorMode=&className= 2/9
2/20/2021 Printer Friendly View
1. Refer to the Transmission category and perform the appropriate diagnostic procedure.
No
1. Go to 2.
1. Go to 3.
No
1. Go to 8.
Install the Transmission Simulator, Miller tool #8333 and the Electronic Transmission Adapter kit.
https://www1.prodemand.com/Print/Index?content=tabs&module=true&tab=true&terms=true&ymms=false&selectorMode=&className= 3/9
2/20/2021 Printer Friendly View
1. Go to 4.
No
1. Go to 5.
1. Replace the Transmission Solenoid/TRS Assembly per the 62TE - SERVICE INFORMATION .
https://www1.prodemand.com/Print/Index?content=tabs&module=true&tab=true&terms=true&ymms=false&selectorMode=&className= 4/9
2/20/2021 Printer Friendly View
https://www1.prodemand.com/Print/Index?content=tabs&module=true&tab=true&terms=true&ymms=false&selectorMode=&className= 5/9
2/20/2021 Printer Friendly View
Measure the resistance of the (T20) L/R Solenoid Control circuit between the appropriate terminal of
Miller tool #8815 and the Solenoid/TRS Assembly harness connector.
Is the resistance above 5.0 ohms?
Yes
1. Go to 6.
6. CHECK THE (T20) L/R SOLENOID CONTROL CIRCUIT FOR A SHORT TO GROUND
https://www1.prodemand.com/Print/Index?content=tabs&module=true&tab=true&terms=true&ymms=false&selectorMode=&className= 6/9
2/20/2021 Printer Friendly View
Fig 2: Measuring Resistance Between Ground And L/R Solenoid Control Circuit
Measure the resistance between ground and the (T20) L/R Solenoid Control circuit.
Is the resistance below 5.0 ohms?
Yes
1. Repair the (T20) L/R Solenoid Control circuit for a short to ground.
https://www1.prodemand.com/Print/Index?content=tabs&module=true&tab=true&terms=true&ymms=false&selectorMode=&className= 7/9
2/20/2021 Printer Friendly View
No
1. Go to 7.
7. CHECK THE (T20) L/R SOLENOID CONTROL CIRCUIT FOR A SHORT TO VOLTAGE
Fig 3: Measuring Voltage Of L/R Solenoid Control Circuit
https://www1.prodemand.com/Print/Index?content=tabs&module=true&tab=true&terms=true&ymms=false&selectorMode=&className= 8/9
2/20/2021 Printer Friendly View
1. Repair the (T20) L/R Solenoid Control circuit for a short to voltage.
1. Using the schematics as a guide, check the Powertrain Control Module (PCM) terminals for
corrosion, damage, or terminal push out. Pay particular attention to all power and ground circuits.
Check for Service Information Tune-ups or Service Bulletins for any possible causes that may
apply. If no problems are found, replace and program the PCM per the 62TE - SERVICE
INFORMATION . With the scan tool, perform QUICK LEARN.
1. Repair as necessary.
1. Test Complete.