Professional Documents
Culture Documents
TDS DC Fair Repair 1610
TDS DC Fair Repair 1610
float or with a damp sponge depending upon This coverage is theoretical and depends upon
the finish required. DC FAIR REPAIR 1610 can the surface profile of the substrate and the
be overcoated 24 hours after application. wastage.
CURING
WATCH POINTS
Generally curing is not necessary for cosmetic
During the summer months or where elevated
repair mortars however particular care is
ambient temperatures are encountered the DC
required in hot and/or windy conditions.
FAIR REPAIR 1610 should be mixed using
chilled water to ensure that the mixed
TECHNICAL DATA temperature does not exceed 32°C.
Working time 60 mins @ 25°C
Do not add cement sand, or which may affect
Setting time 90 mins @ 25°C
its properties.
Density Approx. 1850kg/m³
Compressive Do not add water or fresh mortar to material
strength @ 28 days >15N/mm² which has begun to set.
ASTM C109-98
Pull off strength
>1N/mm²
SAFETY PRECAUTIONS
ASTM D4541 Avoid contact with eyes and prolonged contact
with skin. In case of contact with eyes
TYPICAL PROPERTIES immediately flush for at least 15 minutes with
Supply form Powder fresh clean water. Call a physician. In case of
Water demand per contact with skin wash skin thoroughly.
Up to 5.6 Litres
20 Kg bag
For the full health and safety hazard
Color Grey information and how to safely handle and use
Effect of humidity Same as cement this product, please make sure that you obtain
Physiological effects Same as cement a copy of the DELTA CHEM Material Safety
Toxicity Non-toxic Data Sheet (MSDS) from our office or our
website.
ESTIMATING DATA
A 20 kg bag of DC FAIR REPAIR 1610 mixed
STORAGE
DC FAIR REPAIR 1610 should be stored in dry
with 5.6 litres of water yields 13.8 litres
conditions out of direct sunlight. Shelf life
(0.014m³), therefore One bag of DC FAIR
when stored correctly is 12 months.
REPAIR 1610 will cover 13.8 m² at thickness of
1 mm.
DCL/QA/v2/07_21
STATEMENT OF RESPONSIBILITY
The technical information and application advice given in this DC publication are based on the present state of our best
scientific and practical knowledge. As the information herein is of a general nature, no assumption can be made as to a
product's suitability for a particular use or application and no warranty as to its accuracy, reliability or completeness either
expressed or implied is given other than those required by law. The user is responsible for checking the suitability of products
for their intended use.
NOTE
Field service where provided does not constitute supervisory responsibility. Suggestions made by DC either orally or in
writing may be followed, modified or rejected by the owner, engineer or contractor since they, and not DC, are responsible
for carrying out procedures appropriate to a specific application.
DELTA CHEM
DOHA-STATE OF QATAR
www.DChem.qa