Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 3

 Insert components (compressed air supply, double acting cylinder, 5/n-way valve, and

one-way control valve)


 Configurate 5/n valves, connect with a push button to make it a 5/2 selector switch with 2
outlet ports.
 Put terminator in the unused port of the 5/2 selector switch in order to put an exhaust.
 Connect the air supply to a one port in the 5/2 selector switch which alter to another
outlet port once it is operated.
 Connect each outlet port in the pressure port and vent port of double acting cylinder
 Finally, put the one-way control valve with the ball facing right-side between the
connection of pressure port in the cylinder and the 5/2 selector switch.

 Insert components (compressed air supply, double acting cylinder, 5/n-way valve, and
one-way control valve)
 Configurate 5/n valves, connect with a push button to make it a 5/2 selector switch with 2
outlet ports.
 Put terminator in the unused port of the 5/2 selector switch in order to put an exhaust.
 Connect the air supply to a one port in the 5/2 selector switch which alter to another
outlet port once it is operated.
 Connect each outlet port in the pressure port and vent port of double acting cylinder
 Finally, put the one-way control valve with the ball facing left-side between the
connection of pressure port in the cylinder and the 5/2 selector switch.

 Insert components (compressed air supply, double acting cylinder, 5/n-way valve, and
one-way control valve)
 Configurate 5/n valves, connect with a push button to make it a 5/2 selector switch with 2
outlet ports.
 Put terminator in the unused port of the 5/2 selector switch in order to put an exhaust.
 Connect the air supply to a one port in the 5/2 selector switch which alter to another
outlet port once it is operated.
 Connect each outlet port in the pressure port and vent port of double acting cylinder
 Finally, put the one-way control valve with the ball facing right-side between the
connection of vent port in the cylinder and the 5/2 selector switch.

 Insert components (compressed air supply, double acting cylinder, 5/n-way valve, and
one-way control valve)
 Configurate 5/n valves, connect with a push button to make it a 5/2 selector switch with 2
outlet ports.
 Put terminator in the unused port of the 5/2 selector switch in order to put an exhaust.
 Connect the air supply to a one port in the 5/2 selector switch which alter to another
outlet port once it is operated.
 Connect each outlet port in the pressure port and vent port of double acting cylinder
 Finally, put the one-way control valve with the ball facing left-side between the
connection of vent port in the cylinder and the 5/2 selector switch.
 Insert components (compressed air supply, double acting cylinder, 5/n-way valve, and
one-way control valve)
 Configurate 5/n valves, connect with a push button to make it a 5/2 selector switch with 2
outlet ports.
 Put terminator in the unused port of the 5/2 selector switch in order to put an exhaust.
 Connect the air supply to a one port in the 5/2 selector switch which alter to another
outlet port once it is operated.
 Connect each outlet port in the pressure port and vent port of double acting cylinder
 Finally, put the Quick Exhaust Valve between the connection of vent port in the cylinder
and the 5/2 selector switch.

 Insert components (compressed air supply, double acting cylinder, 5/n-way valve, and
one-way control valve)
 Configurate 5/n valves, connect with a push button to make it a 5/2 selector switch with 2
outlet ports.
 Put terminator in the unused port of the 5/2 selector switch in order to put an exhaust.
 Connect the air supply to a one port in the 5/2 selector switch which alter to another
outlet port once it is operated.
 Connect each outlet port in the pressure port and vent port of double acting cylinder
 put the one-way control valve with the ball facing right-side between the connection of
pressure port in the cylinder and the 5/2 selector switch.

 Finally, put the Quick Exhaust Valve between the connection of vent port in the cylinder
and the 5/2 selector switch.

 Insert components (compressed air supply, double acting cylinder, 3/n-way valve, 5/n-
way valve, and one-way control valve)
 Configurate 5/n valves, connect with a push button and spring return to make it a 5/2
selector switch with 2 outlet ports.
 Configurate 3/n valves, connect with a push button and spring return to make it a 3/2
push button.
 Connect air supply to 5/2 selector switch and 3/2 push button while the released port of
3/2 push button is connected to the input port of 5/2 selector switch making the push
button act as pneumatic source that will actuate the switch selector.

 Insert components (compressed air supply, double acting cylinder, two 3/n-way valve,
5/n-way valve, and one-way control valve)
 Configurate 5/n valves, connect with a push button to make it a 5/2 selector switch with 2
outlet ports.
 Configurate 3/n valves, connect with a push button and spring return to make it a 3/2
push button.
 Connect air supply to 5/2 selector switch and two 3/2 push button while the released port
of two 3/2 push button is connected to the both side input port of 5/2 selector switch
making the push button act as pneumatic source that will actuate the switch selector left
and right.