Insert components (compressed air supply, double acting cylinder, 5/n-way valve, and
one-way control valve)
Configurate 5/n valves, connect with a push button to make it a 5/2 selector switch with 2
outlet ports.
Put terminator in the unused port of the 5/2 selector switch in order to put an exhaust.
Connect the air supply to a one port in the 5/2 selector switch which alter to another
outlet port once it is operated.
Connect each outlet port in the pressure port and vent port of double acting cylinder
Finally, put the one-way control valve with the ball facing left-side between the
connection of pressure port in the cylinder and the 5/2 selector switch.
Insert components (compressed air supply, double acting cylinder, 5/n-way valve, and
one-way control valve)
Configurate 5/n valves, connect with a push button to make it a 5/2 selector switch with 2
outlet ports.
Put terminator in the unused port of the 5/2 selector switch in order to put an exhaust.
Connect the air supply to a one port in the 5/2 selector switch which alter to another
outlet port once it is operated.
Connect each outlet port in the pressure port and vent port of double acting cylinder
Finally, put the one-way control valve with the ball facing right-side between the
connection of vent port in the cylinder and the 5/2 selector switch.
Insert components (compressed air supply, double acting cylinder, 5/n-way valve, and
one-way control valve)
Configurate 5/n valves, connect with a push button to make it a 5/2 selector switch with 2
outlet ports.
Put terminator in the unused port of the 5/2 selector switch in order to put an exhaust.
Connect the air supply to a one port in the 5/2 selector switch which alter to another
outlet port once it is operated.
Connect each outlet port in the pressure port and vent port of double acting cylinder
Finally, put the one-way control valve with the ball facing left-side between the
connection of vent port in the cylinder and the 5/2 selector switch.
Insert components (compressed air supply, double acting cylinder, 5/n-way valve, and
one-way control valve)
Configurate 5/n valves, connect with a push button to make it a 5/2 selector switch with 2
outlet ports.
Put terminator in the unused port of the 5/2 selector switch in order to put an exhaust.
Connect the air supply to a one port in the 5/2 selector switch which alter to another
outlet port once it is operated.
Connect each outlet port in the pressure port and vent port of double acting cylinder
Finally, put the Quick Exhaust Valve between the connection of vent port in the cylinder
and the 5/2 selector switch.
Insert components (compressed air supply, double acting cylinder, 5/n-way valve, and
one-way control valve)
Configurate 5/n valves, connect with a push button to make it a 5/2 selector switch with 2
outlet ports.
Put terminator in the unused port of the 5/2 selector switch in order to put an exhaust.
Connect the air supply to a one port in the 5/2 selector switch which alter to another
outlet port once it is operated.
Connect each outlet port in the pressure port and vent port of double acting cylinder
put the one-way control valve with the ball facing right-side between the connection of
pressure port in the cylinder and the 5/2 selector switch.
Finally, put the Quick Exhaust Valve between the connection of vent port in the cylinder
and the 5/2 selector switch.
Insert components (compressed air supply, double acting cylinder, 3/n-way valve, 5/n-
way valve, and one-way control valve)
Configurate 5/n valves, connect with a push button and spring return to make it a 5/2
selector switch with 2 outlet ports.
Configurate 3/n valves, connect with a push button and spring return to make it a 3/2
push button.
Connect air supply to 5/2 selector switch and 3/2 push button while the released port of
3/2 push button is connected to the input port of 5/2 selector switch making the push
button act as pneumatic source that will actuate the switch selector.
Insert components (compressed air supply, double acting cylinder, two 3/n-way valve,
5/n-way valve, and one-way control valve)
Configurate 5/n valves, connect with a push button to make it a 5/2 selector switch with 2
outlet ports.
Configurate 3/n valves, connect with a push button and spring return to make it a 3/2
push button.
Connect air supply to 5/2 selector switch and two 3/2 push button while the released port
of two 3/2 push button is connected to the both side input port of 5/2 selector switch
making the push button act as pneumatic source that will actuate the switch selector left
and right.