MODEL NUMBER NOMENCLATURE

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
5 0 T C --- A 0 4 A 1 A 5 --- 0 A 0 A 0

Product Type Packaging


50 = Elect Heat Pkg. Rooftop 0 = Standard
1 = LTL
Model Series 3 = CA Seismic Compliant
TC = Standard Efficiency 4 = LTL & CA Seismic Compliant

Heat Size Electrical Options


--- = No heat A = None
C = Non--- fused disconnect
Refrigerant System Options D = Thru the base connections
A = 1--- stage cooling models F = Non=fused disconnect & thru the base
B = 1 stg cooling w/Humidi--- MiZer (04--- 07) G = 2=speed indoor fan (VFD) controller
D --- 2 stage Cooling (08--- 16) J = 2--- spd contr (VFD) & non--- fused disc.
E = 2 stg cooling w/Al/Cu cond. coil and with K = 2--- spd contr (VFD) & thru the base
Humidi--- MiZer (08--- 16) M = 2---spd cont (VFD) non---fused disc. &
thru the base connections
Cooling Tons
04 = 3 ton 08 = 7.5 ton Service Options
05 = 4 ton 09 = 8.5 ton 0 = None
06 = 5 ton 12 = 10 ton 1 = Un--- powered Convenience Outlet
07 = 6 ton 14 = 12.5 ton 2 = Powered Convenience Outlet
16 = 15 ton 3 = Hinged Panels
4 = Hinged Panels, un--- powered C.O.
Sensor Options 5 = Hinged Panels, powered C.O.
A = None
B = RA Smoke Detector Intake / Exhaust Options
C = SA Smoke Detector A = None
D = RA + SA Smoke Detector B = Temperature Economizer w/Barometric Relief
E = CO2 Sensor F = Enthalpy Economizer w/Barometric Relief
F = RA Smoke Detector + CO2 K = 2 position Damper
G = SA Smoke Detector + CO2 U = Temp Ultra Low Leak Economizer w/Baro Relief
H = RA + SA Smoke Detector + CO2 W = Enthalpy Ultra Low Leak Econo w/Baro Relief

Indoor Fan Options Base Unit Controls


1 = Standard Static Option 0 = Base Electromechanical Controls
2 = Medium Static Option 1 = PremierLink Controller
3 = High Static Option 2 = RTU Open Multi--- Protocol Controller
C = High Static Option w/Hi---Effy Motor (16 only) 6 = Electromechanical with 2 speed fan and W7220
Econo controller
Coil Options for round tube plate fin (RTPF) cond. models only
(Outdoor ---Indoor ---Hail Guard) Design Revision
A = Al/Cu --- Al/Cu = Factory Design Revision
B = Pre--- coat Al/Cu --- Al/Cu
C = E--- coat Al/Cu --- Al/Cu Voltage
D = E--- coat AL/Cu --- E--- coat AL/Cu 1 = 575/3/60
E = Cu/Cu --- Al/Cu 3 = 208--- 230/1/60
F = Cu/Cu --- Cu/Cu 5 = 208--- 230/3/60
M = Al/Cu --- Al/Cu --- Louvered Hail Guard 6 = 460/3/60
N = Pre--- Coat Al/Cu --- Al/Cu --- Louvered Hail Guard
P = E--- Coat Al/Cu --- Al/Cu Louvered Hail Guard
Q = E---Coat Al/Cu --- E---coat Al/Cu --- Louvered Hail Guard Note: On single phase (---3 voltage code) models, the
R = Cu/Cu --- Al/Cu --- Louvered Hail Guard Following are not available as a factory installed option:
S = Cu/Cu --- Cu/Cu --- Louvered Hail Guard --- Humidi--- Mizer
Coil Options for all aluminum --- Novation cond. models only --- Coated Coils or CU Fin Coils
(Outdoor ---Indoor ---Hail Guard) --- Louvered Hail Guards
G = Al/Al --- Al/Cu --- Economizer or 2 Position Damper
H = Al/Al --- Cu/Cu --- Powered 115 Volt Convenience Outlet
J = Al/Al --- E--- coat Al/Cu
K = E--- coat Al/Al --- Al/Cu
L = E--- coat Al/Al --- E--- coat Al/Cu
T = Al/A\l --- Al/Cu, Louvered Hail Guard
U = Al/Al --- Cu/Cu, Louvered Hail Guard
V = Al/Al --- E--- coat Al/Cu, Louvered Hail Guard
W = E--- coat Al/Al --- Al/Cu, Louvered Hail Guard
X = E--- coat Al/Al --- E--- coat Al/Cu, Louvered hail Guard

Not all possible options can be displayed above --- see price pages or contact your Carrier Expert for more details.