MY-SK309-66-ME-SP-0001

Specification for Gas Booster


Compressor Package (A-2410A/B) Revision : F1
Page 1 of 1

APPENDIX 1
Datasheets

Mechanical:

Gas Booster Compressor Package Datasheet MY-SK309-66-ME-DS-0001-F0

Process:

Compressor Package Datasheet MY-SK309-66-PR-DS- 0002-F0

Electrical:

Datasheet for Gas Booster Compressor


Package’s Alternator MY-SK309-66-EL-DS- 0001-F0

Datasheet for LV Switchrack MY-SK309-66-EL-DS- 0002-F0

Datasheet for Cooling Pump Motor MY-SK309-66-EL-DS- 0003-F0

Instrument :

Instrument Datasheet MY-SK309-66-IC-DS- 0010-F0


MECHANICAL DATASHEET Equipment No : A-2410A/B
GAS BOOSTER COMPRESSOR PACKAGE - RECIPROCATING COMPRESSOR Equipment Name : Gas Booster Compressor Package

Quantity : Two (2) x 50%


1 DATASHEET IDENTIFICATIONS
2 DOCUMENT NO MY-SK309-66-ME DS-0001
3 DATASHEET IDENTIFICATIONS
4 PROJECT NUMBER MSO-A-0088 SUB PROJECT NO
5 PROJECT PROVISION OF ENGINEERING WORKS FOR GOP-B BOOSTER COMPRESSOR
6
7 ENTERPRISE
8 SITE GOP-B PLATFORM
9 AREA BINTULU, OFFSHORE SARAWAK CELL UNIT Two (2) x 50%
10 DATASHEET IDENTIFICATIONS
11 TAG NUMBER/EQUIPMENT NAME K-2410A/B & K-2420A/B (1ST STAGE & 2ND STAGE COMPRESSOR)
12 SERVICE GAS BOOSTER
13 PFD/P&ID NUMBER MY-SK309-66-PR-DW-0004-01-F0
14 LINE NUMBER
15 APPLICABLE TO GAS BOOSTER COMPRESSOR
16 OPERATING DATA
o
17 Vapour or gas handled : Hydrocarbon gas Aftercooler outlet temperature : Note 21 C
18 Process gas to be kept oil free : yes / no Maximum allowable temperature of fluid
o
19 Operation : continous / intermittent / parallel during compression : 140 C
20 Entrainment : solids / liquids / no Recommended number of stages : Two (2) (VTA)
21 Corrosive gas : yes / no / due to H2S, CO2 (Contain Sands) Power : 615.6 (Note 20) kW
22 Hazardous service : yes / no
23
24 OPERATING CONDITIONS (NOTE 4, 13 & 22)
25 Case 1 Case 2 Case 3 Case 4
26 Mass Flowrate kg/h * * * *
27 Standard Volumetric Flow rate (Design) (Note 18) MMscfd 5.04 5.18 5.20 5.2
28 Inlet Volumetric Flowrate Am3/h * * * *
29 Outlet Volumetric Flowrate Am3/h * * * *
30 Inlet pressure (Note 19) bar g 2.7 2.7 2.7 2.7
31 Discharge Pressure (Note 19) bar g
32 Compressor Discharge Pressure at Final Stage bar g 30 30.0 30.0 30.0
o
33 Inlet temperature (Note 19) C 56.0 50.2 50.1 51.5
o
34 Discharge temperature C * * * *
35 Mol. Weight at inlet (Note 19) * * * *
36 Cp / Cv at inlet * * * *
37 Cp at inlet kJ/kgK * * * *
38 Z (compressibility factor) at inlet (Note 19) 0.9923 0.9917 0.9916 0.9917
39 Z (compressibility factor) at discharge * * * *
40 Guarantee case : Note 13
41
42 GENERAL REQUIREMENTS
43 Type : vertical / horizontal-balanced opposed Capacity control : pockets / valve unloaders / speed variation/
44 Direction of rotation (facing driven end) : cw / ccw VTA by-pass / reverse flow / none
45 Maximum allowable speed : See Note 3 below RPM Range of control : from 100% to 0 VTA %
46 Cooling required on : cylinders / cylinder heads / stuffing box VTA Method of control : in steps / infinite continous VTA
47 Cooling by : thermosyphon / forced circulation : manual / automatic
48 Closed cooling water system : yes / no / by others Number of steps : 5 VTA
49 Cooling water : fresh / brackish / salt Not Available Type of lubrication of cylinders : forced lubricated-single plunger per point
o
50 Cooling water max. temp. at inlet : N/A C Type of lubrication of motion work : VTA
o
51 Cooling water max. allowable temp. at outlet : N/A C Crankcase ventilation : no / vented / purged* VTA
52 Cooling water pressure : N/A bar ga Distance piece : single / single - extra long / double (Type 2)
2
53 Cooling water fouling coefficient : N/A W/m K vented / purged*
54
55 CONNECTIONS Types of valves : VTA
56 Suction flange : ANSI class See Note 4 below Types of bearings : sleeve / roller
57 flange facing : smooth / serrated spiral RF * Purge pressure to be stated by manufacturer, if not given
58 Discharge flange : ANSI class See Note 4 below LOCATION
59 flange facing : smooth / serrated spiral RF General : indoor / outdoor / under roof / partial side walls /
60 with or without lifting facilities
61 Barometric pressure : (15 m from above sea level) mbar
o
62 Ambient temperatue : max. /normal/ min. 35 / - / 20 C
63 Relative humidity : 13%(minimum) - 100%(maximum) %
64 Other :
65 Winterization : yes / no (Tropicalisation required)
66 IP Area Classification : safe / zone 2
67 Temperature Class : T3 Gas Group : IIA
68
69 Notes :
70 "VTA/*" denotes information to be furnished by VENDOR.
71 1. The Compressor package shall be designed, manufactured and tested in accordance with ISO 13631. As an alternative, a horizontally
72 opposed compressor is preferred due to space and weight constraint.
73 2. VENDOR shall submit compressor performance data for each operating case and propose the guarantee case for PURCHASER review.
74 3. The maximum average piston speed allowed is 6 m/s. The application of high speed compressor up to 1200 RPM is subjected to COMPANY approval.
75 4. Refer to datasheet (doc. No MY-SK309-66-PR-DS-0002 page 6) for process condition, process flow scheme and skid package.
76 5. VENDOR shall include and perform pipe stress analysis for piping within package. Based on the analysis, VENDOR shall recommend the piping support required to
77 ensure piping vibration are mitigated.
78 6. Manual barring may be achieved by turning the flywheel, provided that the arrangement is such that the barring tool cannot be retained. The barring device shall be designed
79 so that gas forces acting on the pistons cannot cause the compressor either to accelerate or to rotate in the reverse direction.
80
PROJECT TITLE : PROVISION OF ENGINEERINGWORKS FOR GOP-B

BOOSTER COMPRESSOR

MMC PROJECT NUMBER : MSO-A-0088 F1 23/06/2020 Re-Approved for Bid FD MSO/AA ABS
F0 06/5/2020 Approved for Bid FD MSO/AA ABS
CONTRACT NUMBER : MURPHY/S18039/W.O.R NO.025 REV DATE REV DESCRPTION AUTHOR CHECKED APPROVED PTTEP

Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 1 of 17

Datasheet No. MY-SK309-66-ME DS-0001


Client : PTTEP, SARAWAK
Specification No. MY-SK309-66-ME-SP-0001

Sheet 1 of 17
MECHANICAL DATASHEET Equipment No : A-2410A/B

GAS BOOSTER COMPRESSOR PACKAGE - RECIPROCATING COMPRESSOR Equipment Name : Gas Booster Compressor Package
Quantity : Two (2) x 50%

1 ACCESSORIES MATERIAL SPECIFICATION (Note 7)


2 Base plate : combined / separate Part ASTM No.
3 Foundation bolts : yes / no Cylinders VTA
4 Gear box : yes / no / double helical VTA Liner VTA
5 API service factor : 2.0 (ISO 13691) Piston VTA
6 Coupling(s) make / type : VTA Piston rings VTA
7 V-belts : yes / no , anti-static Piston wear band VTA
8 Grooved motor pulley : yes / no Piston rod VTA
9 Guards : yes / no Piston rod assembly VTA
10 Start-up screen : yes / no / by others VTA VTA
11 Air inlet filter : yes / no / by others Valve seats VTA
12 Intercooler(s) : yes / no / by others water / air cooled Valve plates VTA
13 Aftercooler : yes / no / by others water / air cooled Valve springs VTA
14 Pulsation dampening inlet / outlet each cylinder : yes VTA
15 Dampening by : dampeners / volume bottles Pulsation dampeners * VTA
16 Pulsation suppression analysis : yes / no / design approach 3 (Note 5) or volume bottles*
17 By-pass valve : yes / no / by others VTA Inter/aftercoolers VTA
18 Safety relief valve : yes / no / by others
19 Liquid separators/Suction scrubber : yes / no / by others Lube oil coolers Duplex SS for oil temperature >70 o C
20 Automatic governer or unloader : yes / no / by others VTA
21 Controlled by : suction pressure / discharge pressure Liquid separators VTA
22 Crankcase explosion relief device : yes / no
23 Luboil heater : yes / no steam / electric
24 Barring device : manual / pneumatic / electric (Note 6)
25 Oil coolers : water / air cooled * Design code ASME VIII
26 TESTS (Note 8)
27 Inspection or test Required Witnessed
28 COMPRESSOR DRIVE Shop inspection Mandatory yes / no
29 Electric motor (single bearing) / steam turbine / combustion engine Hydrostatic test Mandatory yes / no
30 Direction of rotation (facing driving end) VTA CW / CCW Leakage test yes / no yes / no
31 Speed : constant / variable Mechanical running test Mandatory yes / no
32 Estimated nominal power : 1100 (VTA) kW Perfomance test yes / no yes / no
33 Drive : direct / gear / V-belt VTA Complete unit test yes / no yes / no
34 Assembly check yes / no yes / no
35 Post test inspection Mandatory yes / no
36 GAS COMPOSITION INLET
37 Mol. fraction
Component
38 Case 1: Max Gas Case 2: Max Oil Case 3: Max Water Case 4: Min Oil
39 Oxygen
40 Nitrogen
41 Methane
42 CO2
43 Ethane
44 Propane
45 i-Butane
46 n-Butane
47 i-Pentane
48 n-Pentane
49 Hexanes
50 Heptanes REFER TO PROCESS DATASHEET FOR GAS
51 Octanes BOOSTER COMPRESSOR MY-SK309-66-PR-DS-
52 Nonanes
0002 (PAGE 7)
53 Decanes
54 Undecanes
55 Dodecanes (C12+1)
56 H20
57 TOTAL
58
59
60
61
62
63

Sheet 2 of 17
MECHANICAL DATASHEET Equipment No : A-2410A/B

GAS BOOSTER COMPRESSOR PACKAGE - RECIPROCATING COMPRESSOR Equipment Name : Gas Booster Compressor Package
Quantity : Two (2) x 50%

1 INSTRUMENTATION REQUIREMENTS
2 General
3 Local instrument panel yes / no / by others
4 combined for compressor and drive instrumentation yes/ no
5 Compressor control system yes / no / by others
6 Compressor safeguarding system yes / no / by others
7
8 Pressure Instruments
9 Pressure of: Indicator Connection (s)
10 Inlet / interstage / discharge of compressor yes / no / by others yes / no
11 Discharge of lube oil pump yes / no / by others yes / no
12 Differential across lube oil filters yes / no / by others yes / no
13 Purge gas on piston rod seal assembly yes / no / by others yes / no
14 Purge on distance pieces ( inboard / outboard section) yes / no / by others yes / no
15 Purge on crankcase yes / no / by others VTA yes / no VTA
16 Discharge of water circulation pump yes / no / by others yes / no VTA
17 Cylindrical ends no yes / plugged / valved
18
19 Temperature Instruments
20 Temperature of: Indicator Connection (s)1)
21 Inlet / discharge of each compressor cylinder 2) yes / no / by others yes / no
22 Cylindrical cooling fluid yes / no yes / no
23 Lube oil tank yes / no yes / no
24 Lube oil at inlet / outlet of lube oil cooler yes / no yes / no
25 Water at inlet / outlet of lubeoil cooler yes / no / by others yes / no
26 Water at inlet / outlet of interstage coolers / aftercoolers yes / no / by others yes / no
27 Water at inlet / outlet of closed cooling system cooler yes / no / by others yes / no
28 Closed cooling system reservoir yes / no / by others yes / no
29
30 Level Instruments
31 Level of: Indicator Connection (s)
32 Expansion tank thermal syphon system yes / no VTA yes / no VTA
33 Lube oil reservoir for motion work yes / no yes / no
34 Lube oil reservoir for cylindrical lubrication yes / no yes / no
35
36 SAFETY, ALARM AND SHUTDOWN DEVICES*
37 Alarm Shutdown Other Description Required
38 High compressor discharge temperature2) each cylinder yes / no / connections only
39 Extra high compressor discharge temp. 2) each cylinder yes / no / connections only
40 Low lube oil pressure yes / no / connections only
41 Extra low lube oil pressure yes / no / connections only
42 High lube oil temperature at cooler outlet VTA yes / no / connections only
43 High pressure over lube oil filter yes / no / connections only
44 High liquid level in scrubber yes / no / connections only
45 High high liquid level in scrubber yes / no / connections only
46 High cylinder C.W. temperature VTA yes / no / connections only
47 Low level thermal syphon expansion tank VTA yes / no / connections only
48 Low oil level in cylinder lubricator yes / no
49 Piston rod run-out (proximity probe) yes / no
50 High discharge cooler temperature by others yes / no
51 High high discharge cooler temperature by others yes / no
52 Low liquid level in scrubber yes / no
53 Low low liquid level in scrubber yes / no
54 High high and low low pressure at the suction of 1st stage yes / no
55 * Indicate by an "X" the action required, state description of "other" action, where applicable.
56 1)
Shall include thermowell
57 2)
Location to be as close as possible to valves
58
59
60
61
62

Sheet 3 of 17
MECHANICAL DATASHEET Equipment No : A-2410A/B

GAS BOOSTER COMPRESSOR PACKAGE - RECIPROCATING COMPRESSOR Equipment Name : Gas Booster Compressor Package
Quantity : Two (2) x 50%

1 ADDITIONAL REQUIREMENTS
2 Notes (continued) :
3
4 7. VENDOR to propose suitable material for the given compositions in sheet 4. Material of construction shall be in accordance with Apendix 2 : Material Selection
5 Diagram of Corrosion Design Basis Memorandum doc no. : MY-SK309-66-PM-DG-0001-00-F0 as a minimum. In general, Gas Booster Compressor Package
6 shall be carbon steel materials.
7 8. Factory Acceptance Test shall include compressor control panel and field instruments. Site Acceptance Test shall also be included
8 in VENDOR's scope of supply.
9 9. Vibration protection system shall be provided.
10 10. VENDOR shall submit a completed API/ISO data sheets - for compressor, gearbox (if applicable), coupling, motor, etc.
11 11. VENDOR shall complete and submit pressure vessel data sheet for each pulsation bottle and scrubber with bid.
12 12. Material certification shall be in accordance with EN 10204 Type 3.1 for wetted and non-wetted pressure parts.
13 Others non-pressure parts materials shall be in accordance with EN 10204 Type 2.2 as minimum.
14 13. Design cases are as per following:
15 CASE 1 : MAXIMUM GAS CASE - YEAR JUNE 2022
16 CASE 2 : MAXIMUM WATER CASE - YEAR MAY 2026
17 CASE 3 : MAXIMUM CONDENSATE/LIQUID CASE - YEAR OCT 2026 (GUARANTEE CASE)
18 CASE 4 : WATER BREAK THROUGH
19 Design guarantee case is based on Maximum Condensate/Water Caser Year 2026 considering the highest volume and the highest absorbed power.
20 The design flow for compressor train is 5.20 MMSCFD (excluding 10% design margin).
21 14. VENDOR to provide the following utility consumptions at normal and peak consumptions, as well as continuous and intermittent usage:
22 A) instrument / utility air - VENDOR to advise any possible technology if instrument/utility air is not available on the platform.
23 B) other utility requirement (if any) - minimum required utilities which are deemed necessary for running booster compressor other than specified above.
24 VENDOR to note following utilities are not available (no ullage) on the platform :-
25 A) Electrical Power
26 B) Fuel Gas
27 15. Utilities available:
28 - Normal instrument air supply pressure = 7.0-7.2 barg, supply temperature = 40 deg C
29 - Design instrument air supply pressure = 13.8 barg, design temperature = 65/0 deg C
30 VENDOR to consider use of fuel gas downstream of suction scrubber which is available at pressure approximately 2.4 barg. VENDOR to consider further
31 treatment (i.e. to install fuel gas scrubber downstream of suction scrubber). VENDOR to note estimated pressure available at gas engne is approximately
32 2.1 barg.
33 16. VENDOR to provide Anti-Vibration Mounting if required.
34 17. VENDOR shall perform vibration analysis as per Design Approach 3.
35 18. VENDOR to include 10% design margin on inlet flowrate.
36 19. Condition/ properties is taken at inlet and discharge battery limit of Gas Booster Compressor Package, A-2410 A/B.
37 20. Highest estimated absorbed power for Case 4. Estimated absorbed power is based on total duty for all 2 stages single shaft and isentropic efficiency of 75%.
38 VENDOR to confirm duty power and isentropic efficiency.
39 21. Discharge gas from battery limit of Gas Booster Compressor shall not exceed 72 deg C.
40 22. Recycle operation cases according to pressurized and depressurized start-up shall be confirmed by VENDOR and included in VENDOR datasheet.
41 23. VENDOR to advise on solid particle size limitation for compressor and gas engines at inlet.
42 24. VENDOR to provide performance guarantee of the booster compressor at the outlet battery limit.
43 25. Booster compressor may experience some sand carry over at the inlet as sand handling system can remove sand particles of 5 micron and larger at 98% efficiency
44 and anticipate carry over of sand. Suction srubber shall be design to remove the fine sand carry over to ensure smooth operation of compressor and gas engine.
45 26. VENDOR to include blow-off case to transfer separated liquid back to compressor discharge line.
46 27. VENDOR to select appropriate internals for booster compressor suction scrubbers. Liquid carry over in gas shall be less than 0.1USG/MMscf.
47 Liquid droplets particles size of 10 microns and greater shall be remove with 99.5%-100% of liquid removal efficiency. VENDOR shall confirm the separation
48 efficiency and pressure drop on the internals of scrubbers..
49 28. The complete package of Gas Booster Compressor Package shall be designed in modules, limited to 10MT each, as limited by the pedestal crane lifting capacity.
50 29. This package shall be provided with Drop Object Protection. Drop object load shall be consider the worst case value which is 235.44kJ (To be advised).
51 30. The overall compressor package shall be limited to 66MT dry weight for each train.
52 31. All package termination flange shall be to/from platform south. Refer below PDMS snapshot.
53
54
55
56
57
58
59
60
61
62

Sheet 4 of 17
MECHANICAL DATASHEET Equipment No : A-2410A/B

GAS BOOSTER COMPRESSOR PACKAGE - GAS ENGINE Equipment Name : Gas Booster Compressor Package
Quantity : Two (2) x 50%

1 DATASHEET IDENTIFICATIONS
2 DOCUMENT NO MY-SK309-66-ME-DS-0001
3
4 ADMINISTRATIVE IDENTIFICATIONS
5 PROJECT NUMBER MSO-A-0088 SUB PROJECT NO
6 PROJECT PROVISION OF ENGINEERING WORKS FOR GOP-B BOOSTER COMPRESSOR
7 ENTERPRISE
8 SITE GOP-B PLATFORM
9 AREA BINTULU, OFFSHORE SARAWAK CELL UNIT
10
11 DEVICE IDENTIFICATION
12 TAG NUMBER A-2410A/B
13 SERVICE GAS BOOSTER
14 PFD/P&ID NUMBER MY-SK309-66-PR-DW-0004
15 LINE NUMBER
16 APPLICABLE TO GAS BOOSTER COMPRESSOR
17 GENERAL
18 EQUIPMENT ITEM NO. A-2410A/B NUMBER REQUIRED ONE FOR EACH COMPRESSOR TRAIN
19 LOCATION MAIN DECK DUTY GAS BOOSTER
20 MAKE VTA MODEL NUMBER VTA
21 ISO CONT. POWER VTA
22 kW SPEED VTA
23 NO. CYLS VTA
24 TURBOCHARGED (YES/ NO) VTA
25 FUEL Gas
26 SPEED VTA
27 TROPICALISATION YES
28 EXH. HEAT RECOVER N/A
29
30 SITE CONDITIONS
31 ENVIRONMENT TROPICAL OFFSHORE EMISSION CONTROL VTA ALLOWABLE EMISSIONS
32 ALTITUDE 15.0m ABOVE SEA LEVEL NDX VTA
33 AMBIENT TEMPERATURES MIN: 20.0°C; MAX: 35.0°C ENGINE OUTPUT VTA
34 RELATIVE HUMIDITY 13%(MIN)-100%(MAX) WINTERISATION N/A
35 AREA CLASSIFICATION ZONE 2 HAZARDOUS AREA
36 EARTHQUAKE ZONE NA
37 CALIFORNIA CLASS VTA
38 TEMPERATURE CLASS T3
39 GAS GROUP IIA
40
41
42 INSTALLATION
43 ENCLOSED BUILDING N/A (NOTE 1) BASEPLATE BY MANUFACTURER
44 ROOF AND PART SIDESHEETING VTA FOUNDATION BOLTS BY MANUFACTURER
45 ROOF ONLY NO CONTROL PANEL BY MANUFACTURER
46 OPEN AIR YES
47 SUBJECT TO FIRE WATER DISCHARGE N/A
48 SKID MOUNTED YES
49 FLOOR MOUNTED N/A
50
51
52 SITE UTILITIES
53 COOLING WATER SEA N/A FRESH N/A COOLING TOWER N/A HEAT REJECTION kJ /hr m³ /hr
54 PRESSURE - PRESSURE DROP - J.W. COOLER VTA VTA
55 TEMPERATURE IN - OUT - L.O. COOLER VTA VTA
56 FLOW - TURBOCHARGER AFTERCOOLER VTA VTA
57 ELECTRICITY TOTAL VTA VTA
58 POWER 415 V, 50Hz, 3 ph
59 UTILITY CONSUMPTION VTA
60 INSTRUMENT A.C 240 V, 50Hz, 1 ph RADIATOR FANS VTA
61 INSTRUMENT D.C - FUEL PUMP VTA
62 INSTRUMENT AIR 7-7.2 barg CIRC. WATER N/A
63 SUMP HEATER N/A BATTERY CHARGER VTA
64 JACKET HEATER N/A UTILITIES VTA
65 INSTRUMENT A.C VTA
66 INSTRUMENT D.C -
67 CYLINDER LUBRICATION VTA
68
69 OPERATION
70 FULLY MANUAL -
71 MANUAL STOP YES
72 FULLY AUTOMATIC YES
73 OTHER (SPECIFY) -
74
75
76 ENGINE DESIGN DATA
77 MAKE VTA MODEL NUMBER VTA
78 NO. CYLS IN LINE VTA VEE VTA DISPLACEMENT VTA
79 DESIGN SPEED MAX VTA MIN VTA
80 CYLINDER HEADS HIGH VTA MEDIUM VTA LOW VTA
81 EXHAUST MANIFOLD : DRY N/A
82 INSULATED YES
83 WATER COOLED VTA
84 WATER JACKET VTA
85
86 POWER ENGINE
87 ISO GROSS VTA BORE VTA STROKE VTA
88 SITE SERVICE GROSS VTA BMEP VTA
89 AUXILIARIES VTA COMBUSTION AIR FLOW VTA
90 COOLANT PUMPS VTA CHARGE AIR TEMPERATURE VTA
91 RADIATOR FANS VTA EXH. TEMPERATURE AFTER TC VTA
92 CHARGING ALTERNATOR VTA COMPRESSION RATIO
93 AIR COMPRESSOR N/A MECHANICAL VTA OVERALL VTA
94 OTHER COOLANT TEMPERATURES: VTA
95 JACKETS VTA
96 TC A/C VTA
97 LUBE OIL COOLER VTA
98 COOLANT SYSTEM PRESSURE: CYCLE N/A
99 NETT. COUPLING OUTPUT VTA TWO N/A
100 MAXIMUM COUPLING OUTPUT FOUR STROKE YES
101 1 HOUR IN 12 VTA VTA
102 MINIMUM ALLOWABLE LOAD VTA MEAN PISTON VELOCITY AT RATED LOAD
103 PERFORMANCE CURVE DRG NO. VTA
104
105
106 GOVERNOR (NOTE 2) TURBOCHARGER
107 TYPE VTA NUMBER VTA
108 ACCURACY CLASS VTA SPEED VTA MAX VTA MIN VTA
109 TRANSIENT SPEED CHANGE VTA CHARGE PRESSURE VTA
110 LOAD INCREASE VTA EXHAUST INLET TEMPERATURE VTA
111 RECOVERY TIME N/A LUBRICATION FROM ENGINE
112 POWER VARIATION BAND N/A STARTING VTA
113 LOAD SHARING N/A MAKE VTA
114 EXTERNAL SPEED SIGNAL VTA MODEL NUMBER VTA
115 GOVERNOR MAKE VTA
116 MODEL NUMBER VTA
117 SYSTEM ELECTRONIC VTA MECHANICAL VTA
118
119

Sheet 5 of 17
MECHANICAL DATASHEET Equipment No : A-2410A/B

GAS BOOSTER COMPRESSOR PACKAGE - GAS ENGINE Equipment Name : Gas Booster Compressor Package
Quantity : Two (2) x 50%

120 DATASHEET IDENTIFICATIONS FUEL SYSTEM


121 GAS ENGINE DIESEL ENGINE
122 TYPE CARBURETTOR VTA FUEL INJECTION VTA FUEL PUMPS
123 NO. OF CARBURETTORS VTA INJECTION TIMING
124 MAKE VTA FUEL PUMP MAKE
125 MODEL NUMBER VTA MODEL NUMBER
126 LEAN BURN VTA FUEL INJECTOR MAKE
127 PRECOMBUSTION CHAMBER VTA MODEL NUMBER
128 FUEL VTA FILTRATION
129 PRESSURE VTA FILTER MAKE
130 TEMPERATURE VTA MODEL NUMBER
131 FLOW @ MAX. POWER VTA
132 * See for fuel Analysis FUEL SUPPLY PRESSURE
133 TEMPERATURE NOT APPLICABLE
134 IGNITION SYSTEM (NOTE 3) FLOW @ MAX. POWER
135 CLASSIFICATION OPEN LOW FIRE HAZARD YES FUEL SPECIFICATION
136 POWER SELF POWERED YES EXTERNAL
137 MAGNETO VTA
138 COILS MAKE VTA
139 MODEL NUMBER VTA * See for fuel Analysis
140 NO. SPARK PLUGS PER CYCLINDER VTA DAY TANK BY MANUFACTURER OTHERS
141 SPARK PLUG MAKE VTA DAY TANK VOLUME
142 MODEL NUMBER VTA RUNNING TIME
143 FUEL CHARGE PUMP ENGINE DRIVEN DRIVER
144
145
146
147 BARRING GEAR LOAD COUPLING
148 TYPE MANUAL VTA SUPPLIED BY MANUFACTURER YES OTHER
149 PNEUMATIC YES TORSIONALLY FLEXIBLE YES RIGID
150 ELECTRIC VTA FLEXIBILITY *
151 PNEUMATIC PRESSURE VTA TYPE FLEXIBLE ELEMENTS *
152 ELECTRIC VTA
153 MAKE VTA MAKE *
154 MODEL NUMBER VTA MODEL NUMBER *
155
156
157 LUBRICATION STARTING
158 TYPE SPLASH PRESSURE YES ELECTRIC (NO. OF MOTORS) ONE (PRIMARY STARTING SYSTEM)
159 PUMP DRIVE ENGINE YES OTHER
160 PRELUBE PUMP YES BATTERIES BY MANUFACTURER YES OTHER
161 DRIVE MANUAL BATTERIES Ni-Cd ALKALINE
162 PNEUMATIC CAPACITY VTA
163 ELECTRIC YES MAKE VTA
164 OTHER MODEL NUMBER VTA
165 OIL FILTER OIL FILTER BATTERY CHARGER ENGINE MAINS A.C
166 FULL FLOW YES CHARGER BY MANUFACTURER YES OTHER
167 BYPASS MAKE VTA
168 DUAL WITH CHANGEOVER VALVE YES MODEL NUMBER VTA
169 FILTRATION VTA STARTER MOTORS VTA
170 MAKE VTA MAKE VTA
171 MODEL NUMBER VTA MODEL NUMBER VTA
172 CENTRIFUGAL FILTER FITTED VTA
173 SUMP CAPACITY VTA PNEUMATIC MOTOR -
174 CIRC. RATE VTA AIR NOT AVAILABLE
175 TEMPERATURE TO COOLER VTA GAS -
176 TEMPERATURE FROM COOLER VTA DIRECT CYLINDER INJECTION -
177 HEAT REJECTION RATE VTA INJECTION TO NO.
178 CONSUMPTION VTA PRESSURE 10 BARG
179 LUBE OIL TYPE VTA FLOW
180 GRADE VTA MIN. PRESSURE TO START VTA
181 VISCOSITY VTA STARTER MOTORS VTA
182 AUTOMATIC SUMP LEVEL CONTROL VTA MAKE VTA
183 OIL COOLER SHELL & TUBE - LIQUID VTA
184 RADIATOR YES AIR RECEIVER VOLUME: VTA
185 COOLANT AIR VTA RECEIVER BY MANUFACTURER YES OTHERS
186 INTEGRATED WITH JACKET VTA DRAWING NUMBER
187 CIRCULATING WATER VTA AIR COMPRESSOR BY MANUFACTURER OTHERS
188 COOLER BY MANUFACTURER YES OTHERS VTA DRIVE ENGINE ELECTRIC MOTOR
189 CAPACITY
190 POWER CYLINDER LUBRICATION ENGINE SYSTEM VTA
191 SEPARATE LUBRICATOR VTA HYDRAULIC VTA YES - SECONDARY STARTING SYSTEM (OPTIONAL) (NOTE 8)
192 SYSTEM PUMP TO POINT WITH SIGHT GLASSES VTA PRESSURE VTA
193 PUMP AND METERING VTA FLOW VTA
194 DRIVER ENGINE VTA MIN. PRESSURE TO START VTA
195 ELECTRIC MOTOR STARTER MOTORS VTA
196 NO. PUMPS VTA MAKE VTA
197 REPLENISH FROM ENGINE SEPARATE MODEL NO. VTA
198 CONSUMPTION VTA ACCUMULATOR VOLUME VTA
199 LUBE OIL TYPE VTA HYDRAULIC SYSTEM BY MANUFACTURER OTHERS
200 GRADE VTA PUMP DRIVE ENGINE
201 LUBRICATOR MAKE VTA MANUAL
202 MODEL NUMBER VTA ELECTRIC
203 HYDRAULIC SYSTEM DRG. NO.
204 LUBE OIL SUPPLY TO DRIVEN MACHINE VTA
205
206 FLOW RATE VTA
207 TEMPERATURE IN VTA OUT VTA
208
209
210
211
212
213
214
215
216
217
218
219 COOLING (NOTE 4) AIR INTAKE (NOTE 5)
220 J.W. COOLER AIR YES WATER FILTER TYPE DRY
221 TC AFTERCOOLER AIR WATER YES FILTRATION QUALITY VTA
222 SYSTEM OPERATING PRESSURE FILTER MAKE VTA
223 PUMP DRIVER ENGINE YES ELECTRIC MODEL NUMBER VTA
224 J.W COOLER BY MANUFACTURER YES OTHER INTAKE DUCT BY MANUFACTURER YES OTHERS
225 RADIATOR ON ENGINE VTA SEPARATE VTA
226 RADIATORS FANS. NO VTA
227 RADIATORS FANS DIA. VTA EXHAUST(NOTE 6)
228 PUMP MAKE VTA DUCT BY MANUFACTURER YES OTHERS YES (DOWNSTREAM
229 MODEL NUMBER VTA SILENCER SPARK ARRESTER YES OF SILENCER)
230 J.W. COOLER MAKE VTA SILENCER MAKE VTA
231 MODEL NUMBER VTA MODEL NUMBER VTA
232
233
234 SCHEDULE OF CUSTOMER CONNECTIONS DIMENSIONS AND WEIGHTS
235 STATE SIZE AND RATING OF CONNECTION LENGTHS VTA
236 FUEL VTA WEIGHT VTA
237 AIR INTAKE VTA BARE ENGINE DIMENSIONS LENGTH VTA
238 AIR FILTER OUT VTA WIDTH VTA
239 EXHAUST VTA HEIGHT VTA
240 SILENCER VTA ENGINE & INTEGRAL RADIATOR LENGTH VTA
241 COOLANT IN VTA OUT VTA WIDTH VTA
242 J.W. COOLER IN VTA OUT VTA HEIGHT VTA
243 AIR/ GAS TO STARTER VTA SEPARATE RADIATOR LENGTH VTA
244 HYDRAULIC OIL IN N/A OUT N/A WIDTH VTA
245 FUEL VENT/ SPILL VTA HEIGHT VTA
246 STARTER EXHAUST VTA HT. TO REMOVE PISTON VTA
247 CRANKCASE BREATHER VTA MIN DIST. BETWEEN ENGINES VTA
248
249 OPERATING WEIGHT VTA
250 MAX. MAINTENANCE LIFT VTA
251 ITEM
252 RADIATOR OPERATING WEIGHT VTA
253 MAX. SHIPPING WEIGHT LENGTH VTA
254 WIDTH VTA
255 HEIGHT VTA
256
257

Sheet 6 of 17
MECHANICAL DATASHEET Equipment No : A-2410A/B

GAS BOOSTER COMPRESSOR PACKAGE - GAS ENGINE Equipment Name : Gas Booster Compressor Package
Quantity : Two (2) x 50%

258 DATASHEET IDENTIFICATIONS FUEL GAS ANALYSIS


259 MOLAR MASS
260 PRESSURE
261 TEMPERATURE
262 Cp/ Cv REFER TO PROCESS DATASHEET FOR GAS BOOSTER
263 DEWPOINTS
264 HYDROCARBON @
COMPRESSOR, MY-SK309-66-PR-DS-0002 (PAGE 7)
265 WATER @
266 HEATING VALUE
267 HIGHER
268 LOWER
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285 DIESEL FUEL SPECIFICATION
286 TO SPECIFICATION
287 DENSITY AT 15°C
288 KINEMATIC VISCOSITY AT 100°C
289 FLASH POINT
290
291
CONRADSON CARBON RESIDUE
WATER
NOT APPLICABLE
292 SULPHUR
293 APPROX. CETANE NUMBER
294
295 ADDITIONAL REQUIREMENTS
296
297 PRESSURE GAUGE YES GB PR. GAUGE SHELL SIDECOOLING WATER INLET/ OUTLET N/A
298 PRESSURE INDICATOR AIR INLET YES LP PR. GAUGE TUBE SIDE COOLING WATER INLET / OUTLET N/A
299 FUEL LEVEL GAUGE YES GB TEMP. GAUGE SHELL SIDE COOLING WATER INLET/ OUTLET N/A
300 TEMPERATURE GAUGE LUBE OIL YES GB TEMP. GAUGE TUBE SIDE COOLING WATER IN LET / OUTLET N/A
301 BATTERY FAILURE N/A N/A ALARM (A,V) BUILT IN IN THE CONTROLLER YES
302 TACHOMETER YES LP TEMP. GAUGE, EXHAUST GAS (LOCAL) N/A
303 LOW LUBE OIL PRESSURE YES LP/ALARM/TRIP
304 HIGH WATER TEMP. AT ENGINE OUTLET YES LP/ALARM
305 LOW RECEIVER AIR PRESSURE YES LP/ALARM
306 LOW FUEL OIL LEVEL/ FUEL PRESSURE YES LP/ALARM
307 LOW WATER LEVEL IN MAKE UP TANK VTA
308 ENGINE OVER SPEED YES LP/ALARM/SHUTDOWN
309 ENGINE FAILS TO START YES ALARM
310 ALL THE INSTRUMENTATION AS PER THE ATTACHED P&ID YES
311
312
313
314 LEGENDS:
315 LP - LOCAL PANEL
316 GB - GAUGE BOARD
317 INSPECTION & TEST
318 TESTING REQUIREMENT TO BE WITNESSED BY BUYER. ENGINE SHALL BE TESTED IN ACCORDANCE WITH NFPA 20. AS A MINIMUM FOLLOWING TESTS SHALL BE AS FOLLOWS:
319 PERFORMANCE TEST YES
320 ENGINE CONTROL YES
321 HYDRAULIC TEST OF FUEL TANK N/A
322 NOISE LEVEL TEST YES
323 VIBRATION TEST YES
324 EMISSION TEST YES
325 COMPONENT IDENTIFICATIONS (*)
326 COMPONENT TYPE GAS BOOSTER COMPRESSOR DRIVE REFERENCE (VTA)
327 MANUFACTURER NAME VTA
328 MANUFACTURER COUNTRY VTA
329 MANUFACTURER CONTACT (E-MAIL) VTA
330 MANUFACTURER HOMEPAGE VTA
331 MANUFACTURER DATE VTA
332 MODEL NUMBER VTA
333 MANUFACTURER PART NUMBER VTA
334 SERIAL NUMBER VTA
335 PURCHASE ORDER VTA
336
337
338
339 NOTES
340 1. Enclosed Building is not applicable. However, VENDOR to quote an acoustic enclosure as an OPTIONAL. Material handling equipment within the package shall be provided by VENDOR.
341 2. Engine speed shall be governed in accordance with ISO 3046-4.
342 3. The ignition system shall be a self-contained, electronic based and DC-powered that suitable for Zone 2 Hazardous Area Classification.
343 4. Cooling water system shall be in closed circuit system. Water top up will be done manually. VENDOR to provide approximate amount of top up water required.
344 5. Air intake shall be from non hazardous area. Refer equipment layout.
345 6. Exhausts components and all other working surfaces of the engine shall not exceed the temperature limits 200 deg C as outlined in EEMUA 107 when the engine is operating at service power and at the design ambient temperature.
346 7. Refer to Technical Requisition Package for Gas Booster Compressor Package document number MOM-SK309-66-ME-SP-0001 for scope of supply and technical requirement.
347 8. Secondary starting system shall be hydraulic. VENDOR to quote as an OPTIONAL.
348 9. VENDOR to provide Anti-Vibration Mounting if required.
349 10. If Gas Engine Generator is required, all requirement for gas engine shall be as per this datasheet except for rating and tag no. VENDOR to advise rating and tag no.
350 ( VTA ) Vendor to advise (N/A) Not Available
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379

Sheet 7 of 17
MECHANICAL DATASHEET Equipment No : A-2410A/B

GAS BOOSTER COMPRESSOR PACKAGE - PRESSURE VESSEL Equipment Name : Gas Booster Compressor Package
Quantity : Two (2) x 50%
1 DATASHEET IDENTIFICATION
2 DOCUMENT NO. MY-SK309-66-ME-SP-0001
3
4 DATASHEET IDENTIFICATION
5 PROJECT NUMBER MSO-A-0088 SUB PROJECT NO -
6 PROJECT PROVISION OF ENGINEERING WORKS FOR GOP-B BOOSTER COMPRESSOR
7
8 ENTERPRISE -
9 SITE BINTULU, OFFSHORE SARAWAK
10 AREA GOP-B PLATFORM CELL : - UNIT :
11 (GOP-B)
12 DEVICE IDENTIFICATION
13 TAG NUMBER V-2410A/B & V-2420A/B QUANTITY Four (4)
14 SERVICE 1st STAGE & 2nd STAGE GAS SCRUBBER
15 CONTENT HYDROCARBON GAS / HYDROCARBON LIQUID / WATER
16 PFD/P&ID NUMBER MY-SK309-66-PR-DW-0004
17 LINE NUMBER -
18 APPLICABLE TO GAS BOOSTER COMPRESSOR
19 1. PROCESS DATA PROCESSS DESIGN CONDITIONS
20 PROCESS CONDITIONS MINIMUM NORMAL MAXIMUM UNITS
21 OPERATING TEMPERATURE * * * °C
22 OPERATING PRESSURE * * * bar g
23 NORMAL / MIN. VAC. CONDITIONS * * * mbar abs
24 DESIGN TEMPERATURE UPPER, LOWER * * * °C
25 DESIGN PRESSURE INTERNAL / EXTERNAL * * * bar g
26 TEST PRESSURE HYDROSTATIC / PNEUMATIC PER CODE / SPEC bar g
27 CASE DESIGN
28 VAPOUR FLOW kg/hr
29 VAPOUR FLOW MMSCFD
30 CONDENSATE FLOW (NOTE 7) kg/hr
31 CONDENSATE FLOW Am³/hr
32 WATER FLOW kg/hr
33 WATER FLOW Am³/hr
34
NOTE 6
35 VAPOUR MOLECULAR WEIGHT
36 VAPOUR DENSITY kg/m³
37 VAPOUR VISCOSITY cP
38
39 HC LIQUID DENSITY kg/m³
40 HC LIQUID VISCOSITY cP
41 HC LIQUID SURFACE TENSION dyne/cm
42
43 WATER DENSITY - kg/m³
44 WATER VISCOSITY - cP
45 WATER SURFACE TENSION - dyne/cm
46
47 HEATING/ COOLING MEDIUM MAX. QUANTITY REQUIRED - kg/h
48 DIAMETER OF SHELL OD/ID * (NOTE 1) mm
49 LENGTH BETWEEN TANGENT LINES * (NOTE 1) mm
50 TOTAL PACKED HEIGHT - mm
51 HEIGHT PER BED - mm
52 SIZE AND TYPE OF PACKING -
53 NUMBER OF PACKED SECTIONS -
54 NUMBER OF REDISTRIBUTORS -
55 HEIGHT OF SKIRT / TO BOTTOM TANGENT LINE - mm
56 TYPE OF HEADS 2: 1 ELLIPSE HEADS mm
57 WALL THICKNESS -SHELL / HEAD SHELL: * (NOTE 1) HEAD: * (NOTE 1) mm
58 CORROSION ALLOWANCE/ LINING/ CLADDING 3mm mm
59 INSULATION THICKNESS - mm
60 TRAYS SPACING/ NUMBER REQUIRED -
61 TYPE -
62 LAY-OUT IN ACCORDANCE WITH SHEET(S) -
63 TOTAL VOLUME (NOTE 1) m³
64 NORMAL LIQUID VOLUME (NOTE 1) m³
65 VOLUME RANGE REQUIRED FOR LEVEL CONTROL REFER TO SCHEMATIC DIAGRAM IN ITEM 14. m³
66
67
68
69

Sheet 8 of 17
MECHANICAL DATASHEET Equipment No : A-2410A/B

GAS BOOSTER COMPRESSOR PACKAGE - PRESSURE VESSEL Equipment Name : Gas Booster Compressor Package

Quantity : Two (2) x 50%

1 WIND PRESSURE N/m²


2 RELIEF VALVE (S) TYPE -
3 SIZE -
4 SET PRESSURE - bar ga
5 NUMBER REQUIRED -
6 ALLOWABLE PRESSURE DROP 0.1 bar
7 CALCULATED PRESSURE DROP NOTE 1 bar
8 FLUID CONTENT HYDROCARBON
9 WIND LOAD NOTE 8
10 SEISMIC LOAD -
11 TRANSPORTATION LOAD NOTE 9
12 EARTHQUAKE FACTOR NOT APPLICABLE
13 VESSEL CATEGORY CATEGORY 2
14
15 SITE DATA
16 ELEVATION TOS EL +15000 ABOVE SEA LEVEL AREA CLASS - GROUP - DIV. -
17 BAROMETER - CLASSIFICATION ZONE 2 GROUP IIA TEMP. CLASST3
18 MAXIMUM AMBIENT TEMPERATURE 35 UNIT °C RELATIVE HUMIDITY MAXIMUM100
19 NORMAL AMBIENT TEMPERATURE - UNIT °C (%) MINIMUM 13
20 MINIMUM AMBIENT TEMPERATURE 20 UNIT °C UNUSUAL DUST FUMES -
21 ORIENTATION: VERTICAL CONDITIONS WINTERIZATION REQUIRED -
22 LOCATION : LOWER DECK TROPICALIZATION REQUIRED YES
23 INDOOR HEATED - OTHER -
24 UNHEATED -
25 OUTDOOR UNDER ROOF -
26 PARTIAL SIDES -
27 GRADE MEZZANINE -
28 CELLAR DECK -
29
30 DEVICE SPECIFICATION
31 2. BODY (NOTE 1)
32 PART ASTM NO. PART ASTM NO.
33 SHELL SA 516 70N + 3mm CA + Internal Coating below LC STIFFENING RINGS -
34 (Note 14)
35 CLADDING / LINING OF SHELL - INSULATION SUPPORT RINGS -
36 HEADS SA 516 70N + 3mm CA + Internal Coating below LC CLEATS FOR PLATFORMS. ETC SA 516 70N
37 (Note 14)
38 CLADDING / LINING OF HEADS - INTERNAL PARTS SS 316L
39 BOOT - DOWNCOMERS -
40 REINFORCING RINGS PAD SA 516 70N BAFFLES SS 316L
41 SKIRT, BASE PLATE, ETC. SA 516 70N INTERNAL PIPE FITTINGS SS 316L
42 SADDLES - STUD BOLTS, EXTERNAL SA 193 B7M
43 JACKET - NUTS, EXTERNAL SA 194 2HM
44 SHELL FLANGES - BOLTS, INTERNAL SA 193 GR B8M
45 NOZZLES (LINE PIPE / PLATE) SA 106 Gr B/SA 516 GR 70N/SA 105 N / SA 350 LF2 NUTS, INTERNAL SA 194 2H GR B8M
46 LINER OF NOZZLES AND MANHOLES - GASKETS, EXTERNAL SPIRAL WOUND with SS316 inner and outer ring
47 FLANGES (ANSI / ASME) SA 105 N GASKETS, INTERNAL SPIRAL WOUND with SS316 inner and outer ring
48 FLANGES (NON- ANSI) -
49 WELDING FITTINGS SA 216 GR. WCB
50
51 3. NOZZLE DATA (NOTE 1)
52 Mark No Service Size (mm) Rating/Facing Nozzle Projection Remarks
53 N1 1 INLET * 150#/ RF WN * NOTE 5
54 N2 1 GAS OUTLET * 150#/ RF WN *
55 N3 1 LIQUID OUTLET / DRAIN * 150#/ RF WN * WITH VORTEX BREAKER
56 N4 1 PSV * 150#/ RF WN *
57 N5 1 EDUCTOR NOZZLE * 150#/ RF WN * NOTE 2
58 N6 1 UTILITY CONNECTION * 150#/ RF WN * NOTE 4
59
60
61
62
63
64
65
66
67
68
69
70
71

Sheet 9 of 17
MECHANICAL DATASHEET Equipment No : A-2410A/B

GAS BOOSTER COMPRESSOR PACKAGE - PRESSURE VESSEL Equipment Name : Gas Booster Compressor Package
Quantity : Two (2) x 50%
1 4. INSTRUMENT CONNECTION (NOTE 1)
2 I1 1 PRESSURE GAUGE * 150#/ RF WN
3 I2A/B 2 LEVEL TRANSMITTER * 150#/ RF WN HIGH /LOW LEVEL ALARM INDICATOR (NOTE 4)
4 I3A/B 2 LEVEL TRANSMITTER * 150#/ RF WN LOW LOW LEVEL TRIP (NOTE 4)
5 I4A/B 2 LEVEL TRANSMITTER * 150#/ RF WN HIGH HIGH LEVEL TRIP (NOTE 4)
6 I5A/B 2 LEVEL GAUGE * 150#/ RF WN
7
8
9
10
11 5. MANHOLES/HANDHOLDS/INSPECTION COVERS (VTA)
12
13
14
15 6. COMPONENT DESIGN CRITERIA
16
17
18 7. MATERIAL PROPERTIES
19 -
20
21 8. PERFORMANCE CHARACTERISTICS
22 -
23
24 9. ACCESSORIES
25 LIFTLING LUG SA 516 70N DEMISTER / VANE PACK SS 316L
26 NAME PLATE SS 316L HIGH EFFICIENCY INLET DEVICE OR EQUIVALENT YES
27 BRIDLE SUPPORT SA 516 70N
28 LADDER AND PLATFORM SA 36 or EQ
29
30 10. SPECIAL REQUIREMENTS
31 ARRANGEMENT - CONSTRUCTION - OUTLINE REFER SCHEMATIC IN SHEET 10 OF 15 ANCHOR BOLT RING AND BASE PLATE -
32 STANDARD VESSEL - LIFTLING LUG *
33 ADDITIONAL DRAWINGS - NAME PLATE *
34 WELDING ELECTRODES, RODS, ETC. * SUPPORT RING/CLEATS (INSULATION) -
35 GENERAL REMARKS VESSELS AS PER NOTE INSPECTION (MANHOLE/DAVITS, ETC) *
36 FLANGED PIPE NOZZLES D12.92.019 PROCESS INTERNALS -
37 THERMOWELL NOZZLES - BRIDLE SUPPORT -
38 STAINLESS STEEL FLANGES -
39 VORTEX BREAKER -
40 SADDLES *
41 EARTHING BOSS *
42 CLEATS FOR PLATFORMS. ETC *
43
44 11. PHYSICAL DATA
45 DRY WEIGHT * (NOTE 1) TONS WEIGHT OF INTERNALS (NOTE 1) kg
46 OPERATING WEIGHT * (NOTE 1) TONS WEIGHT OF INSULATION (NOTE 1) kg
47 HYDROTEST WEIGHT * (NOTE 1) TONS WEIGHT OF FIREPROOFING (NOTE 1) kg
48
49 12. CALIBRATIONS AND TEST
50 CONSTRUCTION IN ACCORDANCE WITH : MOM-SWK-10-PC-SP-0001-00 & ASME SECTION VIII DIV.2 (LATEST ED.) (U-STAMP - OPTIONAL)
51 TAG NUMBER TEST
52 INSPECTION AUTHORITY YES (DOSH-OPTIONAL) AND AUTHORISED INSPECTION AGENCY (AIA)
53 STRESS RELIEVING PER CODE / SPEC
54 SPECIAL HEAT TREATMENT PER CODE / SPEC
55 RADIOGRAPHY 100%
56 OTHER NON-DESTRUCTIVE TESTING (HYDROTEST ETC.) PER CODE / SPEC
57 PICKLING AND PASSIVATING REQUIRED FOR SS PARTS AND WELDS
58 MATERIAL CERTIFICATES EN 10204 - 2.2 (NON PRESSURE PART) / EN 10204 - 3.1 (PRESSURE PART)
59 IMPACT TESTING PER CODE / SPEC
60 JOINT EFFICIENCY 1.0
61 EXTERNAL / INTERNAL COATING AS PER SPECIFICATION
62 MANUFACTURER'S CERTIFICATE CHEMICAL ANALYSIS REQUIRED, PMI
63 MECHANICAL DATA REQUIRED
64 HEIGHT OF SKIRT TO VESSEL * / TBA
65
66
67
68
69
70

Sheet 10 of 17
MECHANICAL DATASHEET Equipment No : A-2410A/B

GAS BOOSTER COMPRESSOR PACKAGE - PRESSURE VESSEL Equipment Name : Gas Booster Compressor Package

Quantity : Two (2) x 50%

1 13. COMPONENT IDENTIFICATION


2 COMPONENT TYPE NOTE 1
3 MANUFACTURER NAME NOTE 1
4 MANUFACTURER COUNTRY NOTE 1
5 MANUFACTURER CONTACT (E-MAIL) NOTE 1
6 MANUFACTURER HOMEPAGE NOTE 1
7 MANUFACTURER DATE NOTE 1
8 MODEL NUMBER NOTE 1
9 MANUFACTURER PART NUMBER NOTE 1
10 SERIAL NUMBER NOTE 1
11 PURCHASE ORDER NOTE 1
12 DRIVE REFERENCE NOTE 1
13
14 14. SCHEMATIC DIAGRAM (NOTE 1)
15
16
17
18
19
20
21
22
23
24
25
26
27
28
V-2410A/B & V-
29
2420A/B VTA
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45 VTA
46
47 NOTES
48 1. *VENDOR TO ADVICE / CONFIRM.
49 2. LOCATE EDUCTOR NOZZLE AS FAR FROM MANWAY AS POSSIBLE.
50 3. HIGH EFFICIENCY INLET DEVICE OR EQUIVALENT.
51 4. ALARM AND SHUTDOWN TRANSMITTER NOZZLES (UPPER/LOWER) SHALL BE LOCATED AT THE SAME ELEVATION.
52 5. INLET PIPING CENTRE LINE TO BE IN THE SAME ORIENTATION AS VESSEL CENTRE LINE FOR A MINIMUM OF 10D. VENDOR TO ADVICE FLOW
53 STRAIGHTENING DEVICE AS REQUIRED.
54 6. REFER TO PROCESS DATASHEET DOCUMENT NO. MY-SK309-66-PR-DS-0002-00
55 7. CONDENSATE MASS FLOW IS BASED ON 1% OF VAPOUR MASS FLOW.
56 8. WIND LOAD FACTOR IS REFERENCE TO +10METRES ABOVE MSL AS PER SK309311 METAOCEAN DATA ATTACHED IN APPENDIX 2.
57 9. TRANSPORTATION LOAD SHALL REFER SPECIFICATION FOR GAS BOOSTER COMPRESSOR PACKAGE (DOC NO.: MY-SK309-66-ME-0001-00) SECTION 6.15.
58 10. THE INTERNALS OF GAS BOOSTER COMPRESSOR SUCTION SCRUBBER SHOULD CONSIST OF HIGH EFFICIENCY INLET DEVICE AND VANE PACK. THE LIQUID DROPLET
59 PARTICLE SIZES OF 10 MICRON AND GREATER SHALL BE FILTERED WITH CONSIDERATION 99.5-100% LIQUID REMOVAL EFFICIENCY. LIQUID CARRY OVER
60 IN GAS SHALL BE LESS THAN 0.1 USG/MMscf. VENDORS SHALL CONFIRM THE SEPARATION EFFICIENCY AND PRESSURE DROP OF THE INTERNALS OF SCRUBBER.
61 11. 12A/B AND 15A/B SHALL BE OF THE SAME LEVEL.
62 12. LC = LEVEL CONRTOL
63 13. VENDOR TO ENSURE THE REMAINING FINE SAND CARRY OVER FROM DESANDER SHALL BE FILTER 5 MICRONS AND ABOVE.
64 14. VENDOR TO ADVISE THE FEASIBILITY OF INTERNAL COATING. OTHERWISE, VENDOR TO PROVIDE SUITABLE CLADDED AREA (SS316L).
65
66
67
68
69
70

Sheet 11 of 17
MECHANICAL DATASHEET Equipment No : A-2410A/B
GAS BOOSTER COMPRESSOR PACKAGE - AIR COOLED HEAT EXCHANGER Equipment Name : Gas Booster Compressor Package
Quantity : TWO (2) x 50% (NOTE 13)
1 DATASHEET IDENTIFICATIONS
2 DOCUMENT NO MY-SK309-66-ME DS-0001
3
4 ADMINISTRATIVE IDENTIFICATIONS
5 PROJECT NUMBER MSO-A-0088 SUB PROJECT NO -
6 PROJECT PROVISION OF ENGINEERING WORKS FOR GOP-B BOOSTER COMPRESSOR
7 ENTERPRISE
8 SITE GOP-B PLATFORM
9 AREA BINTULU, OFFSHORE SARAWAK CELL - UNIT -
10
11 DEVICE IDENTIFICATION
12 TAG NUMBER (*)
13 SERVICE 1st STAGE COMPRESSOR DISCHARGE COOLER
14 P&ID NUMBER (*)
15 LINE NUMBER -
16 QUANTITY TWO (2) NOTE 13
17 1. PROCESS DATA PROCESS DESIGN CONDITIONS
18 TYPE
19 INDUCED/FORCED DRAFT/NATURAL FORCED DRAFT
20 DESIGN DUTY kW (*)
21 OVERSURFACE % 10
22 SERVICE HYDROCARBON GAS
23 NO OF UNITS / FANS (*)
24 MANUFACTURER (*)
25 OVERALL SIZE (*)
26 DESIGN TEMP °C (*)
27 DESIGN PRESSURE bar (g) (*)
28 TEST PRESSURE bar (g) -
29 DESIGN CODE API 661 / ISO 13706
30 2. PERFORMANCE DATA
31 MAX DUTY CASE (NOTE 5)
TUBE SIDE GENERAL
32 INLET OUTLET
33 FLUID CIRCULATED kg/hr (*) SURFACE ITEM (m²)
34 TOTAL FLUID ENTERING kg/hr (*) EXTENDED (*)
35 VAPOUR kg/hr (*) BARE (*)
MMSCFD (*) EFFECTIVE MTD (*)
36 HC LIQUID kg/hr (*)
37 WATER kg/hr (*) TRANSFER RATE (W/m²°C) (*)
38 STEAM kg/hr (*) EXTENDED SURFACE (*)
39 NON CONDENSABLE kg/hr (*) BARE SURFACE CLEAN (*)
40 (*) BARE SURFACE DIRTY (*)
41 VAPOUR CONDENSED kg/h (*)
42 LIQUID VAPORISED kg/h (*) BUNDLE SIZE (*)
43 STEAM CONDENSED kg/h (*) BUNDLE /BAY (*)
44 MOL. WT. (VAPOUR) (*) TOTAL BUNDLES (*)
45 MOL. WT. (NON CONDENSABLE) (*)
46 DENSITY (VAP/ HC /LIQ / WATER) kg/m³ (*)
47 VISCOSITY (VAP/ HC /LIQ / WATER) cP (*)
48 THERMAL COND. (VAP/ HC /LIQ / WATER) W/m°K (*)
49 SPECIFIC HEAT (VAP/ HC /LIQ / WATER) kJ/kg°C (*)
50 LATENT HEAT OF VAPORIZATION kJ/kg (*)
51 SURFACE TENSION dyne/cm (*)
52 TEMPERATURE °C (*)
53 PRESSURE bar (g) (*)
COOLING DUTY kW (*)
54 MAX. VELOCITY CRITERIA m/s (*)
PRESSURE DROP AVAILABLE / CALC bar (*)
55
FOULING RESISTANCE m²°C/W (*)
56
57 CORROSION ALLOWANCE mm 3 (*)
58 3. AIR FLOW
59 TOTAL AIR FLOW @ 1 atm, 20°C m³/S (*)
60 AIR FLOW / FAN m³/S (*)
61 ACTUAL STATIC PRESSURE bar (g) (*)
62 DESIGN AIR TEMPERATURE °C (*)
63 (DESIGN DRY BULB)
64 FACE VELOCITY std m/s (*)
65 ALTITUDE m (*)
66 MIN AIR TEMP °C (*)
67 AIR TEMP OUT °C (*)
68 4. SITE DATA :
69 ELEVATION TOS EL +23300 83 AREA CLASSIFICATION CLASS - GROUP - DIV. -
70 BAROMETER - 84 ZONE 2 GROUP 2A TEMP.CLASS T3
71 MAXIMUM AMBIENT TEMPERATURE 35.0 UNIT °C 85 RELATIVE HUMIDITY (%) MAXIMUM 100
72 NORMAL AMBIENT TEMPERATURE - UNIT °C 86 MINIMUM 13
73 MINIMUM AMBIENT TEMPERATURE 20.0 UNIT °C 87 UNUSUAL CONDITIONS DUST - FUMES -
74 88 WINTERIZATION REQUIRED -
75 LOCATION : 89 TROPICALIZATION REQUIRED √
76 INDOOR HEATED - 90 OTHER -
77 UNHEATED - 91
78 OUTDOOR UNDER ROOF - 92
79 PARTIAL SIDES - 93
80 GRADE / LEVEL TOP DECK √ 94
81 95
82 96
97 DEVICE SPECIFICATION
98 5. DESIGN, MATERIAL AND CONSTRUCTION
99 HEADERS 143 TUBES
100 TYPE PLUG 144 TYPE Finned Tube
101 DESIGN PRESSURE (*) 145 DESIGN PRESSURE (*)
102 DESIGN TEMPERATURE MAXIMUM (*) MINIMUM (*) 146 DESIGN TEMPERATURE MAXIMUM (*) MINIMUM (*)
103 TEST PRESSURE AS PER CODE 147 TEST PRESSURE AS PER CODE
104 MIN. DESIGN METAL TEMPERATURE - 148 MIN. DESIGN METAL TEMPERATURE (*)
105 MATERIAL * HEADER SA516 GR 70 149 MATERIAL CARBON STEEL
106 TUBE SHEET SA 105N 150 O.D (*) WALL THICKNESS 2MM (MINIMUM)
107 GASKET SPIRAL WOUND with SS316 inner 151 NO. / BUNDLE (*) EFF. LENGTH (*)
108 & outer ring 152 ROW DEEP (*)
109 CORROSION ALLOWANCE 3 mm 153 PITCH (*)
110 NO. OF PASSES 1 SLOPE NONE 154
111 PLUG MATERIAL SA 105N 155 TUBE BUNDLE
112 PLUG GASKET (*) 156 SIZE (*)
113 157 NO. / BAY (*) NO. OF TUBE ROWS (*)
114 LOUVER 158 BUNDLES IN PARALLEL √ IN SERIES
115 MATERIAL (*) 159 STRUCTURE MOUNTING GRADE
116 ACTION CONTROL (*) AUTO MANUAL 160 PIPE RACK
117 ACTION TYPE (*) OPPOSED PARALEL 161 OTHER √

Sheet 12 of 17
MECHANICAL DATASHEET Equipment No : A-2410A/B
GAS BOOSTER COMPRESSOR PACKAGE - AIR COOLED HEAT EXCHANGER Equipment Name : Gas Booster Compressor Package
Quantity : TWO (2) x 50% (NOTE 13)
118 DATASHEET IDENTIFICATIONS 162 PIPE-RACK BEAMS (DISTANCE C-C) -
119 HEATING COIL N/A 163 LADDERS, WALKWAYS, PLATFORM YES √ NO
120 NO. OF TUBES - O.D - 164 STRUCTURE SURF. PREP./ COATING MOM-SWK-10-QU-SP-0001-00-0
121 TUBE MATERIAL - 165 HEADER SURF. PREP. / COATING MOM-SWK-10-QU-SP-0001-00-0
122 FIN MATERIAL - 166
123 TYPE - 167 FIN DETAILS
124 THICKNESS - 168 TYPE EXTRUDED
125 PRESSURE DESIGN CODE - 169 MATERIAL ALUMINIUM ASTM B209 ALLOY 1068
126 STAMP - 170 THICKNESS (*)
127 HEATING FLUID - FLOW - 171 SELECTION TEMPERATURE (*)
128 TEMPERATURE - 172 O.D (*) NO. (*)
129 INLET PRESSURE - 173 FOULING LAYER THICKNESS (*)
130 PRESSURE DROP (ALLOW./ CALC.) - 174 CUSTOMER SPECIFICATION MY-SK309-66-ME-SP-0001 AND API 661 / ISO 13706
131 DESIGN TEMPERATURE - 175
132 INLET / OUTLET NOZZLE - 176
133 177
134 NOZZLE (VENDOR TO ADVISE)
135 NOZZLE BUNDLE #1 #2 #3 #4 RATING FACING SIZE REMARK
136 INLET 3 (*) (*) (*) 600# WN RF (*) MIN. 2 PER BUNDLE
137 OUTLET 3 (*) (*) (*) 600# WN RF (*) MIN. 2 PER BUNDLE
138 DRAIN 2 (*) (*) (*) 600# WN RF (*) MIN. 1 PER BUNDLE
139 VENT 2 (*) (*) (*) 600# WN RF (*) MIN. 1 PER BUNDLE
140
141 OVERALL SIZE LIMITS L x W x H (INCLUDING ACCESS PLATFORM) *
142
178 6. FANS AND DRIVERS
179 FAN 193 DRIVER Refer to Section 6.8 of Specification for Gas Booster Compressor
180 Package (doc no. MY-SK309-66-ME-SP-0001-F0)
181 MANUFACTURER (*) 194 TYPE (*) NO. / BAY (*)
182 MODEL (*) 195 MANUFACTURER (*)
183 ABSORBED POWER / FAN (*) 196 RATING (*)
184 DIAMETER (*) rpm (*) 197 ELECTRICAL SUPPLY V 240 Ph 1 Hz 50
185 BLADE MATERIAL FRP 198 ENCLOSURE (*)
186 HUB MATERIAL (*) 199 SPEED CONTROL REQUIRED
187 BLADES / FAN AS PER CODE PITCH ANGLE AS PER CODE 200 ESTIMETED POWER (*)
188 BLADE PITCH AS PER CODE 201 HAZARDOUS AREA - MOTOR RATING (*)
189 TEMPERATURE CONTROL AS PER CODE 202 MOTOR ACCESS WALKWAYS REQUIRED
190 VIBRATION SWITCH REQUIRED 203 MAX NOISE LEVEL AT 1 M FROM THE 85 dB(A)
191 BLADE ANGLE AS PER CODE 204 EQUIPMENT
192 LOCAL START/ STOP PUSH BUTTON REQUIRED 205
193 206
194 7. SPEED REDUCER
195 TYPE HTD BELT DRIVE 213 SUPPORT STRUCTURE
196 MANUFACTURER (*) 214 NO. / BAY (*)
197 MODEL (*) 215 RATIO (*)
198 SERVICE FACTOR (*) 216 RATING (*)
199 217
200 8. CONTROLS - AIR SIDE
201 AIR RECIRCULATION EXTERNAL 229 SIGNAL AIR PRESSURE FROM (*) TO (*)
202 DEGREE CONTROL OF OUTLET 230 FROM (*) TO (*)
(*)
203 PROCESS TEMP 231 SUPPLY AIR PRESSURE MAX. (*) MIN (*)
204 (MAX. COOLING). +/- °C 232 MAX. (*) MIN (*)
205 FAN PITCH (*) MINIMUM MAXIMUM LOCKUP 233
206 LOUVERS (*) OPEN CLOSED LOCKUP 234
207 FAN (*) NONE POSITIONER BIAS RELAY 235
208 LOUVERS (*) INLET OUTLET BYPASS 236
209 POSITIONER (*) YES NO 237
210 238
211 9. COMPONENT DESIGN CRITERIA
212 BANK CONSTRUCTION : 261 DESIGN CODE API 661 / ISO 13706
213 06001-SK-EG-ST-STD-GEN-0001 (Rev 7) Specification for Structural Fabrication, Inspection & Testing 262 STRUCTURAL DESIGN CODE REFER MY-SK309-66-ME-SP-0001
214 263 WIND SPEED 32.1 m/s @ 10m above MSL
215 MOM-MUR-10-ST-SP-0001-03 Specification for Structural Materials 264 SEISMIC ZONE -
216 265 IMPORTANCE FACTOR -
217 266 MDMT *
218 267 PWHT AS PER CODE
219 NOISE LIMITATIONS : 268 RADIOGRAPHY AS PER CODE
220 MY-SK309-66-ME-SP-0001-F0 Specification for Gas Booster Compressor Package 269 PAINTING SPECIFICATION AS PER CODE
221 270
222 ELECTRIC MOTORS : 271
223 06001-SK-EG-EL-STD-GEN-0005-00 Specification for LV Induction Motor 272
224 273
225 STRUCTURAL STEEL : 274
226 WELDING ELECTRODES 275
227 GALVANIZING REQUIRED FOR 276
228 277
229 LANGUAGE TO BE USED : 278
230 ON DRAWINGS ENGLISH 279
231 ON NAME PLATE ENGLISH 280
232 281
233 10. MATERIAL PROPERTIES
234 AS PER ASME SECTION II PART D 288
235 289
236 290
237 291
238 292
239 11. PERFORMANCE CHARACTERISTICS
240 - 299
241 300
242 301
243 302
244 303
245 12. ACCESSORIES
246 - 310
247 311
248 312
249 313
250 314
251 13. SPECIAL REQUIREMENTS
252 NOISE DATASHEET REQUIRED √ NOT REQUIRED 321
253 COVER PLATE BOLTING TYPE THROUGH BOLT (*) STUD BOLTS (*) 322
254 323
255 324
256 325

Sheet 13 of 17
MECHANICAL DATASHEET Equipment No : A-2410A/B
GAS BOOSTER COMPRESSOR PACKAGE - AIR COOLED HEAT EXCHANGER Equipment Name : Gas Booster Compressor Package
Quantity : TWO (2) x 50% (NOTE 13)
257 DATASHEET
14. PHYSICALIDENTIFICATIONS
DATA
258 PLOT AREA MAX. (*) m (Note 11) 331 TOTAL (*)
259 BUNDLE WEIGHT (*) kgs 332 SHIPPING (*) kgs
260 BAY (*) 333
261 334
262 15. CALIBRATIONS AND TEST
263 TAG NUMBER TEST YES NO WITNESSED
264 SHOP TEST FOR VIBRATION √ √
265
266
267
268
269 16. COMPONENT IDENTIFICATIONS
270 COMPONENT TYPE (*) 354
271 MANUFACTURER NAME (*) 355
272 MANUFACTURER COUNTRY (*) 356
273 MANUFACTURER CONTACT (E-MAIL) (*) 357
274 MANUFACTURER HOMEPAGE (*) 358
275 MANUFACTURER DATE (*) 359
276 MODEL NUMBER (*) 360
277 MANUFACTURER PART NUMBER (*) 361
278 SERIAL NUMBER (*) 362
279 PURCHASE ORDER (*) 363
280 364
281 17. SCHEMATIC DIAGRAM *
282
283
284
285
286
287
288
289
290
291 18. NOTES
292 * VENDOR to advise / confirm.
293 1. VENDOR shall provide 10% excess tube surface area.
294 2. Ambient temperature data are taken from MY-SK309-66-ME-SP-0001 – SPECIFICATION FOR GAS BOOSTER COMPRESSOR PACKAGE
295 3. Other material requirement are:
296 Nozzle : SA 106 GR B
297 Gasket nozzle : SPIRAL WOUND with SS316 inner & outer ring
298 Flange : SA 105N
299 Lifting Lug : A36 or equivelant
300 Nameplate : SS 316L
301 Earthing Boss : CS
302 PMI : Yes
303 Stress relieved : Per Code (All NDT acceptance after PWHT, if PWHT is performed)
304 Manufacturer certificate : EN 10204 Type 3.1 / ISO 10474 Type 3.1B
305 Impact test : Per Code
306 4. As minimum, performance testing shall include the following:
307 a) Hydrotest of pressure containing parts
308 b) Functional test (current test, temp, etc.)
309 c) Vibration measurement of assembled cooler.
310 5. Flowrate, Process data and duty shall be based on VENDOR design and calculation. Design of the package shall meet the package inlet and outlet process
311 datasheet Doc. No. MY-SK309-66-PR-DS-0002-00.
312 6. All stainless steel surface shall be descaled / pickled, if any.
313 7. Drain/vent 50mm (2") diameter to be provided with blind, Quantity required depend on the number of passes. Minimum one (1) nos each per bay.
314 8. 100% radiography required.
315 9. Noise level shall be as measured at 1 meter from skid edge with all the fans running.
316 10. All tubes for the cooler shall be fully expanded and "partial" strength weld into the tubesheet grooves. Jointing shall be as per the requirement of API 661.
317 Vendor alternate proposal to be review for acceptance.
318 11. Seal leak test for tube-to-tubesheet joints shall be as per API 661 clause 12.4.1.
319 12. Design life for air coolers is 15 years.
320 13. One (01) unit for each compressor train, K-2410A/B.
321 14. Noise level shall be measured at 1m from the equipment surface accessible to personnel, or any position where a worker's ear may be exposed to noise during normal working condition.
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339

Sheet 14 of 17
MECHANICAL DATASHEET Equipment No : A-2410A/B
GAS BOOSTER COMPRESSOR PACKAGE - AIR COOLED HEAT EXCHANGER Equipment Name : Gas Booster Compressor Package
Quantity : TWO (2) x 50% (NOTE 13)
1 DATASHEET IDENTIFICATIONS
2 DOCUMENT NO MY-SK309-66-ME DS-0001
3
4 ADMINISTRATIVE IDENTIFICATIONS
5 PROJECT NUMBER MSO-A-0088 SUB PROJECT NO -
6 PROJECT PROVISION OF ENGINEERING WORKS FOR GOP-B BOOSTER COMPRESSOR
7 ENTERPRISE
8 SITE GOP-B PLATFORM
9 AREA BINTULU, OFFSHORE SARAWAK CELL - UNIT -
10
11 DEVICE IDENTIFICATION
12 TAG NUMBER (*)
13 SERVICE 2nd STAGE COMPRESSOR DISCHARGE COOLER
14 P&ID NUMBER (*)
15 LINE NUMBER -
16 QUANTITY TWO (2) NOTE 13
17 1. PROCESS DATA PROCESS DESIGN CONDITIONS
18 TYPE
19 INDUCED/FORCED DRAFT/NATURAL FORCED DRAFT
20 DESIGN DUTY kW (*)
21 OVERSURFACE % 10
22 SERVICE HYDROCARBON GAS
23 NO OF UNITS / FANS (*)
24 MANUFACTURER (*)
25 OVERALL SIZE (*)
26 DESIGN TEMP °C (*)
27 DESIGN PRESSURE bar (g) (*)
28 TEST PRESSURE bar (g) -
29 DESIGN CODE API 661 / ISO 13706
30 2. PERFORMANCE DATA
31 MAX DUTY CASE (NOTE 5)
TUBE SIDE GENERAL
32 INLET OUTLET
33 FLUID CIRCULATED kg/hr (*) SURFACE ITEM (m²)
34 TOTAL FLUID ENTERING kg/hr (*) EXTENDED (*)
35 VAPOUR kg/hr (*) BARE (*)
MMSCFD (*) EFFECTIVE MTD (*)
36 HC LIQUID kg/hr (*)
37 WATER kg/hr (*) TRANSFER RATE (W/m²°C) (*)
38 STEAM kg/hr (*) EXTENDED SURFACE (*)
39 NON CONDENSABLE kg/hr (*) BARE SURFACE CLEAN (*)
40 (*) BARE SURFACE DIRTY (*)
41 VAPOUR CONDENSED kg/h (*)
42 LIQUID VAPORISED kg/h (*) BUNDLE SIZE (*)
43 STEAM CONDENSED kg/h (*) BUNDLE /BAY (*)
44 MOL. WT. (VAPOUR) (*) TOTAL BUNDLES (*)
45 MOL. WT. (NON CONDENSABLE) (*)
46 DENSITY (VAP/ HC /LIQ / WATER) kg/m³ (*)
47 VISCOSITY (VAP/ HC /LIQ / WATER) cP (*)
48 THERMAL COND. (VAP/ HC /LIQ / WATER) W/m°K (*)
49 SPECIFIC HEAT (VAP/ HC /LIQ / WATER) kJ/kg°C (*)
50 LATENT HEAT OF VAPORIZATION kJ/kg (*)
51 SURFACE TENSION dyne/cm (*)
52 TEMPERATURE °C (*)
53 PRESSURE bar (g) (*)
COOLING DUTY kW (*)
54 MAX. VELOCITY CRITERIA m/s (*)
PRESSURE DROP AVAILABLE / CALC bar (*)
55
FOULING RESISTANCE m²°C/W (*)
56
57 CORROSION ALLOWANCE mm 3 (*)
58 3. AIR FLOW
59 TOTAL AIR FLOW @ 1 atm, 20°C m³/S (*)
60 AIR FLOW / FAN m³/S (*)
61 ACTUAL STATIC PRESSURE bar (g) (*)
62 DESIGN AIR TEMPERATURE °C (*)
63 (DESIGN DRY BULB)
64 FACE VELOCITY std m/s (*)
65 ALTITUDE m (*)
66 MIN AIR TEMP °C (*)
67 AIR TEMP OUT °C (*)
68 4. SITE DATA :
69 ELEVATION TOS EL +23300 83 AREA CLASSIFICATION CLASS - GROUP - DIV. -
70 BAROMETER - 84 ZONE 2 GROUP 2A TEMP.CLASS T3
71 MAXIMUM AMBIENT TEMPERATURE 35.0 UNIT °C 85 RELATIVE HUMIDITY (%) MAXIMUM 100
72 NORMAL AMBIENT TEMPERATURE - UNIT °C 86 MINIMUM -
73 MINIMUM AMBIENT TEMPERATURE 20.0 UNIT °C 87 UNUSUAL CONDITIONS DUST - FUMES -
74 88 WINTERIZATION REQUIRED -
75 LOCATION : 89 TROPICALIZATION REQUIRED √
76 INDOOR HEATED - 90 OTHER -
77 UNHEATED - 91
78 OUTDOOR UNDER ROOF - 92
79 PARTIAL SIDES - 93
80 GRADE / LEVEL TOP DECK √ 94
81 95
82 96
97 DEVICE SPECIFICATION
98 5. DESIGN, MATERIAL AND CONSTRUCTION
99 HEADERS 143 TUBES
100 TYPE PLUG 144 TYPE (*)
101 DESIGN PRESSURE (*) 145 DESIGN PRESSURE (*)
102 DESIGN TEMPERATURE MAXIMUM (*) MINIMUM (*) 146 DESIGN TEMPERATURE MAXIMUM (*) MINIMUM (*)
103 TEST PRESSURE AS PER CODE 147 TEST PRESSURE AS PER CODE
104 MIN. DESIGN METAL TEMPERATURE - 148 MIN. DESIGN METAL TEMPERATURE (*)
105 MATERIAL * HEADER SA516 GR 70 149 MATERIAL CARBON STEEL
106 TUBE SHEET SA 105N 150 O.D (*) WALL THICKNESS 2MM (MINIMUM)
107 GASKET SPIRAL WOUND with SS316 inner 151 NO. / BUNDLE (*) EFF. LENGTH (*)
108 & outer ring 152 ROW DEEP (*)
109 CORROSION ALLOWANCE 3 mm 153 PITCH (*)
110 NO. OF PASSES 1 SLOPE NONE 154
111 PLUG MATERIAL SA 105N 155 TUBE BUNDLE
112 PLUG GASKET (*) 156 SIZE (*)
113 157 NO. / BAY (*) NO. OF TUBE ROWS (*)
114 LOUVER 158 BUNDLES IN PARALLEL √ IN SERIES
115 MATERIAL (*) 159 STRUCTURE MOUNTING GRADE
116 ACTION CONTROL (*) AUTO MANUAL 160 PIPE RACK
117 ACTION TYPE (*) OPPOSED PARALEL 161 OTHER √

Sheet 15 of 17
MECHANICAL DATASHEET Equipment No : A-2410A/B
GAS BOOSTER COMPRESSOR PACKAGE - AIR COOLED HEAT EXCHANGER Equipment Name : Gas Booster Compressor Package
Quantity : TWO (2) x 50% (NOTE 13)
118 DATASHEET IDENTIFICATIONS 162 PIPE-RACK BEAMS (DISTANCE C-C) -
119 HEATING COIL N/A 163 LADDERS, WALKWAYS, PLATFORM YES √ NO
120 NO. OF TUBES - O.D - 164 STRUCTURE SURF. PREP./ COATING MOM-SWK-10-QU-SP-0001-00-0
121 TUBE MATERIAL - 165 HEADER SURF. PREP. / COATING MOM-SWK-10-QU-SP-0001-00-0
122 FIN MATERIAL - 166
123 TYPE - 167 FIN DETAILS
124 THICKNESS - 168 TYPE EXTRUDED
125 PRESSURE DESIGN CODE - 169 MATERIAL ALUMINIUM ASTM B209 ALLOY 1068
126 STAMP - 170 THICKNESS (*)
127 HEATING FLUID - FLOW - 171 SELECTION TEMPERATURE (*)
128 TEMPERATURE - 172 O.D (*) NO. (*)
129 INLET PRESSURE - 173 FOULING LAYER THICKNESS (*)
130 PRESSURE DROP (ALLOW./ CALC.) - 174 CUSTOMER SPECIFICATION MY-SK309-66-ME-SP-0001 AND API 661 / ISO 13706
131 DESIGN TEMPERATURE - 175
132 INLET / OUTLET NOZZLE - 176
133 177
134 NOZZLE
135 NOZZLE BUNDLE #1 #2 #3 #4 RATING FACING SIZE REMARK
136 INLET 3 (*) (*) (*) 600# WN RF (*) MIN. 2 PER BUNDLE
137 OUTLET 3 (*) (*) (*) 600# WN RF (*) MIN. 2 PER BUNDLE
138 DRAIN 2 (*) (*) (*) 600# WN RF (*) MIN. 1 PER BUNDLE
139 VENT 2 (*) (*) (*) 600# WN RF (*) MIN. 1 PER BUNDLE
140
141 OVERALL SIZE LIMITS L x W x H (INCLUDING ACCESS PLATFORM) *
142
178 6. FANS AND DRIVERS
179 FAN 193 DRIVER Refer to Section 6.8 of Specification for Gas Booster Compressor
180 Package (doc no. MY-SK309-66-ME-SP-0001-F0)
181 MANUFACTURER (*) 194 TYPE (*) NO. / BAY (*)
182 MODEL (*) 195 MANUFACTURER (*)
183 ABSORBED POWER / FAN (*) 196 RATING (*)
184 DIAMETER (*) rpm (*) 197 ELECTRICAL SUPPLY V 240 Ph 1 Hz 50
185 BLADE MATERIAL FRP 198 ENCLOSURE (*)
186 HUB MATERIAL (*) 199 SPEED CONTROL REQUIRED
187 BLADES / FAN AS PER CODE PITCH ANGLE AS PER CODE 200 ESTIMETED POWER (*)
188 BLADE PITCH AS PER CODE 201 HAZARDOUS AREA - MOTOR RATING (*)
189 TEMPERATURE CONTROL AS PER CODE 202 MOTOR ACCESS WALKWAYS REQUIRED
190 VIBRATION SWITCH REQUIRED 203 MAX NOISE LEVEL AT 1 M FROM THE 85 dB(A)
191 BLADE ANGLE AS PER CODE 204 EQUIPMENT
192 LOCAL START/ STOP PUSH BUTTON REQUIRED 205
193 206
194 7. SPEED REDUCER
195 TYPE HTD BELT DRIVE 213 SUPPORT STRUCTURE
196 MANUFACTURER (*) 214 NO. / BAY (*)
197 MODEL (*) 215 RATIO (*)
198 SERVICE FACTOR (*) 216 RATING (*)
199 217
200 8. CONTROLS - AIR SIDE
201 AIR RECIRCULATION EXTERNAL 229 SIGNAL AIR PRESSURE FROM (*) TO (*)
202 DEGREE CONTROL OF OUTLET 230 FROM (*) TO (*)
(*)
203 PROCESS TEMP 231 SUPPLY AIR PRESSURE MAX. (*) MIN (*)
204 (MAX. COOLING). +/- °C 232 MAX. (*) MIN (*)
205 FAN PITCH (*) MINIMUM MAXIMUM LOCKUP 233
206 LOUVERS (*) OPEN CLOSED LOCKUP 234
207 FAN (*) NONE POSITIONER BIAS RELAY 235
208 LOUVERS (*) INLET OUTLET BYPASS 236
209 POSITIONER (*) YES NO 237
210 238
211 9. COMPONENT DESIGN CRITERIA
212 BANK CONSTRUCTION : 261 DESIGN CODE API 661 / ISO 13706
213 06001-SK-EG-ST-STD-GEN-0001 (Rev 7) Specification for Structural Fabrication, Inspection & Testing 262 STRUCTURAL DESIGN CODE REFER MY-SK309-66-ME-SP-0001
214 263 WIND SPEED 32.1 m/s @ 10m above MSL
215 MOM-MUR-10-ST-SP-0001-03 Specification for Structural Materials 264 SEISMIC ZONE -
216 265 IMPORTANCE FACTOR -
217 266 MDMT *
218 267 PWHT AS PER CODE
219 NOISE LIMITATIONS : 268 RADIOGRAPHY AS PER CODE
220 MY-SK309-66-ME-SP-0001-F0 Specification for Gas Booster Compressor Package 269 PAINTING SPECIFICATION AS PER CODE
221 270
222 ELECTRIC MOTORS : 271
223 06001-SK-EG-EL-STD-GEN-0005-00 Specification for LV Induction Motor 272
224 273
225 STRUCTURAL STEEL : 274
226 WELDING ELECTRODES 275
227 GALVANIZING REQUIRED FOR 276
228 277
229 LANGUAGE TO BE USED : 278
230 ON DRAWINGS ENGLISH 279
231 ON NAME PLATE ENGLISH 280
232 281
233 10. MATERIAL PROPERTIES
234 AS PER ASME SECTION II PART D 288
235 289
236 290
237 291
238 292
239 11. PERFORMANCE CHARACTERISTICS
240 - 299
241 300
242 301
243 302
244 303
245 12. ACCESSORIES
246 - 310
247 311
248 312
249 313
250 314
251 13. SPECIAL REQUIREMENTS
252 NOISE DATASHEET REQUIRED √ NOT REQUIRED 321
253 COVER PLATE BOLTING TYPE THROUGH BOLT (*) STUD BOLTS (*) 322
254 323
255 324
256 325

Sheet 16 of 17
MECHANICAL DATASHEET Equipment No : A-2410A/B
GAS BOOSTER COMPRESSOR PACKAGE - AIR COOLED HEAT EXCHANGER Equipment Name : Gas Booster Compressor Package
Quantity : TWO (2) x 50% (NOTE 13)
257 DATASHEET
14. PHYSICALIDENTIFICATIONS
DATA
258 PLOT AREA MAX. (*) m (Note 11) 331 TOTAL (*)
259 BUNDLE WEIGHT (*) kgs 332 SHIPPING (*) kgs
260 BAY (*) 333
261 334
262 15. CALIBRATIONS AND TEST
263 TAG NUMBER TEST YES NO WITNESSED
264 SHOP TEST FOR VIBRATION √ √
265
266
267
268
269 16. COMPONENT IDENTIFICATIONS
270 COMPONENT TYPE (*) 354
271 MANUFACTURER NAME (*) 355
272 MANUFACTURER COUNTRY (*) 356
273 MANUFACTURER CONTACT (E-MAIL) (*) 357
274 MANUFACTURER HOMEPAGE (*) 358
275 MANUFACTURER DATE (*) 359
276 MODEL NUMBER (*) 360
277 MANUFACTURER PART NUMBER (*) 361
278 SERIAL NUMBER (*) 362
279 PURCHASE ORDER (*) 363
280 364
281 17. SCHEMATIC DIAGRAM *
282
283
284
285
286
287
288
289
290
291 18. NOTES
292 * VENDOR to advise / confirm.
293 1. VENDOR shall provide 10% excess tube surface area.
294 2. Ambient temperature data are taken from MY-SK309-66-ME-SP-0001 – SPECIFICATION FOR GAS BOOSTER COMPRESSOR PACKAGE
295 3. Other material requirement are:
296 Nozzle : SA 106 GR B
297 Gasket nozzle : SPIRAL WOUND with SS316 inner & outer ring
298 Flange : SA 105N
299 Lifting Lug : A36 or equivelant
300 Nameplate : SS 316L
301 Earthing Boss : CS
302 PMI : Yes
303 Stress relieved : Per Code (All NDT acceptance after PWHT, if PWHT is performed)
304 Manufacturer certificate : EN 10204 Type 3.1 / ISO 10474 Type 3.1B
305 Impact test : Per Code
306 4. As minimum, performance testing shall include the following:
307 a) Hydrotest of pressure containing parts
308 b) Functional test (current test, temp, etc.)
309 c) Vibration measurement of assembled cooler.
310 5. Flowrate, Process data and duty shall be based on VENDOR design and calculation. Design of the package shall meet the package inlet and outlet process
311 datasheet Doc. No. MY-SK309-66-PR-DS-0002-00.
312 6. All stainless steel surface shall be descaled / pickled, if any.
313 7. Drain/vent 50mm (2") diameter to be provided with blind, Quantity required depend on the number of passes. Minimum one (1) nos each per bay.
314 8. 100% radiography required.
315 9. Noise level shall be as measured at 1 meter from skid edge with all the fans running.
316 10. All tubes for the cooler shall be fully expanded and "partial" strength weld into the tubesheet grooves. Jointing shall be as per the requirement of API 661.
317 Vendor alternate proposal to be review for acceptance.
318 11. Seal leak test for tube-to-tubesheet joints shall be as per API 661 clause 12.4.1.
319 12. Design life for air coolers is 15 years.
320 13. One (01) unit for each compressor train, K-2420A/B.
321 14. Noise level shall be measured at 1m from the equipment surface accessible to personnel, or any position where a worker's ear may be exposed to noise during normal working condition.
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339

Sheet 17 of 17
NOISE DATASHEET Equipment No : A-2410A/B

GAS BOOSTER COMPRESSOR PACKAGE Equipment Name : Gas Booster Compressor Package

Quantity : Two (2) x 50%

Type of equipment: Mechanical Power: * kW


Supplier / Manufacturer: * Speed: * r / min
Type No.: * Size I x b x h: * x * x * m

1. GENERAL
This requisition cover the noise limits of equipment, given below. For definitions, method of measuring etc. reference is made to
EEMUA specification no. 140 : "Noise procedure specification".

2. NOISE LIMITS TO BE MET BY THE EQUIPMENT


The noise generated by the equipment shall not exceed the more stringent of the noise limits given in the table below, for
any of the conditions of operation for which the equipment may normally be expected to be used.
Lp is the maximum (A-weighted) sound pressure level dB re 20 µPa at any location at 1 m from the equipment surface,
Lw is the maximum (A-weighted) sound power level dB re 1 pW.
If the equipment generates noise with tonal or impulsive components, the limits shall be taken 5 dB(A) more stringent.

3. INFORMATION TO BE SUBMITTED WITH THE TENDER


This noise data sheet shall be returned with the tender and with guaranteed noise data filled in.
Vendor shall state which silencing measures were taken to meet the noise requirements.
Where applicable the completed silencer and/or acoustic enclosure data requisition sheet shall also be returned

Equipment a Sound pressure/power levels guaranteed by supplier in dB b Remarks


items/locations (upper tolerance + 0 dB) Noise
Un-weighted octave-band levels Total limit
63 125 250 500 1 2 4 8
Hz Hz Hz Hz kHz kHz kHz kHz dB(A) dB(A) Silencing measures
85
Motor driver 1

85
Compressor 1

85
Oil Cooler 1

Purchaser shall indicate:


- In column "b", the A-weighted sound pressure/power limit
- In column "a" using the appropriate number, which of the following applies to the required noise levels:
1) without acoustic provisions
2) with acoustic provisions
3) special low-noise design
4) vendor best estimate, not necessarily guaranteed
5) …………………………………………………………………………………………………………….
WEIGHT DATASHEET Equipment No : A-2410A/B

GAS BOOSTER COMPRESSOR PACKAGE Equipment Name : Gas Booster Compressor Package

Quantity : Two (2) x 50%

EQUIPMENT DESCRIPTION INFORMATION STATUS


(Tick as necessary)
Tender est.
Design est.
Heaviest component to be handled during maintenance:- Design update
Description mass KG As supplied
MASS DATA (KG)
NOTES:
1. One sheet shall be completed for each separately installed skid or item.
2. As supplied equipment shall be weighted by vendor and witnessed by purchaser or nominee.
3. Vendor shall provide current calibration certificate of weighing equipment. Calibration methods shall be to BS 1610.
4. Vendor shall submit design update for significant changes in mass.

Dry Kg Operating Kg Test Kg

Other Description Kg
temporary
masses

Certified final mass Date Name Company


Purchaser inspector
Vendor

DIMENSIONAL DATA (mm)


NOTES:
1/ Equipment orientation on each skid or item to be indicated.
2/ C of M Coordinates to be clearly shown on G.A. drawings.

'L'
'X'

OVERALL SIZES
C of M
'W'

DIMENSION 'L'
DIMENSION 'W'
'Y'

DIMENSION 'H'
Plan

CENTRE OF MASS
Dimension Dry Operating
C of M
'H'

'X'
'Z'

'Y'
Elevation 'Z'
PROCESS DATASHEET

FOR

BOOSTER COMPRESSOR PACKAGE

CONTRACT TITLE : PROVISION OF ENGINEERING DESIGN


SERVICES FOR PTTEP'S OPERATION

WORK ORDER TITLE : PROVISION OF ENGINEERING WORKS FOR


GOP-B BOOSTER COMPRESSOR 4 25-06-2020 Internal Issue
RNY KBJ KBJ
3 14-05-2020 Internal Issue
RNY KBJ KBJ
WORK ORDER NUMBER : 025B - GOP-B 2 24-04-2020 Internal Issue
RNY KBJ KBJ
1 23-03-2020 Internal Issue
RNY KBJ KBJ
MMC PROJECT NUMBER : MSO-A-0088 0 13-03-2020 Internal Issue
RNY KBJ KBJ
A 29-01-2020 Internal Issue
RNY KBJ KBJ
PREPARED CHECKED APPROVED APPROVED
CONTRACT NO. MURPHY/S18039 REV DATE REVISION DESCRIPTION
: MMC MMC MMC PTTEP
Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 1 cont'd on sheet No. 2

Datasheet No. MY-SK309-66-PR-DS-0002-00


Client : PTTEP Sarawak Oil Limited (993918-P)
PTTEP Sabah Oil Limited (993919-M) Specification No.
PROJECT DESCRIPTION

GOP-B IS GAS PRODUCING PLATFORM AT SK309 FIELD WITH 12 NUMBERS OF GAS WELLS. CURRENTLY ALL THE WELLS ROUTED TO PRODUCTION
HEADER WHICH IS OPERATING AT 22-24 BARG.

GAS PRODUCTION AT GOP-B IS DEPLETING AND SOME OF THE WELL PRESSURE DEPLETING BELOW PRODUCTION SEPARATOR, V-2030 OPERATING
PRESSURE AND WILL NOT FLOW TO PRODUCTION SEPARATOR, V-2030 IN NEAR FUTURE. TO OVERCOME THE ISSUE, IT IS PROPOSED TO INSTALL
BOOSTER COMPRESSOR TO BOOST THE PRESSURE TO ENABLE LOW PRESSURE (LP) WELLS TO FLOW TO EXISTING PRODUCTION SEPARATOR, V-2030.

UNDER THIS PROJECT, ALL THE LP WELLS WILL BE DIVERTED TO NEW LP PRODUCTION HEADER WHERE ALL THE LP GAS RECEIVED FROM LP WELLS
WILL BE COMMINGLED AND ROUTED TO NEW SAND HANDLING SYSTEM AND BOOSTER COMPRESSOR.

APART FROM LP GAS ISSUE, GOP-B WELLS HAVE POTENTIAL OF SAND IN THE GAS STREAM AND RECOMMENDED TO BE REMOVED BEFORE SENDING
IT TO THE NEW BOOSTER COMPRESSOR.

TO REMOVE SAND IT IS PROPOSED TO INSTALL NEW SAND HANDLING SYSTEM AT THE UPSTREAM OF NEW BOOSTER COMPRESSOR FOR SMOOTH
OPERATION OF BOOSTER COMPRESSOR.

SCOPE OF WORK

- TO INSTALL BOOSTER COMPRESSOR PACKAGE.

VENDOR TO NOTE

VENDOR TO NOTE THAT THE PLATFORM HAS NO ULLAGE IN TERMS OF FUEL GAS AND ELECTRIC POWER SUPPLY. HENCE, NEW BOOSTER
COMPRESSOR WILL BE GE (GAS ENGINE) DRIVE AND PROCESS GAS FROM THE OUTLET OF SAND HANDLING SYSTEM TO BE USED AS FUEL GAS
TO RUN GE. FUEL GAS TO BE ADEQUATELY TREATED BEFORE SUPPLYING IT TO GE.

ADEQUATE INSTRUMENT/UTILITY AIR IS AVAILABLE ON THE PLATFORM TO SUPPLY FOR INSTRUMENTATIONS INSIDE THE PACKAGE. ANY OTHER
REQUIREMENT OF INSTRUMENT/UTILITY AIR, VENDOR TO ADVISE THE COMPANY.

VENDOR TO ADVISE MINIMUM REQUIRED UTILITIES WHICH ARE DEEMED NECESSARY FOR RUNNING BOOSTER COMPRESSOR OTHER THAN SPECIFIED
ABOVE.

VENDOR TO PROPOSE

- BOOSTER COMPRESSOR PACKAGE.


- THE PACKAGE SHALL INCLUDE ALL THE MINIMUM REQUIRED ACCESSORIES TO ENSURE SMOOTH OPERATION OF THE EQUIPMENT WITHOUT ANY
DOWNTIME.

CONTRACT TITLE : PROVISION OF ENGINEERING DESIGN


SERVICES FOR PTTEP'S OPERATION

WORK ORDER TITLE : PROVISION OF ENGINEERING WORKS FOR


GOP-B BOOSTER COMPRESSOR 4 25-06-2020 Internal Issue
RNY KBJ KBJ
3 14-05-2020 Internal Issue
RNY KBJ KBJ
WORK ORDER NUMBER : 025B - GOP-B 2 24-04-2020 Internal Issue
RNY KBJ KBJ
1 23-03-2020 Internal Issue
RNY KBJ KBJ
MMC PROJECT NUMBER : MSO-A-0088 0 13-03-2020 Internal Issue
RNY KBJ KBJ
A 29-01-2020 Internal Issue
RNY KBJ KBJ
PREPARED CHECKED APPROVED APPROVED
CONTRACT NO. MURPHY/S18039 REV DATE REVISION DESCRIPTION
: MMC MMC MMC PTTEP
Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 2 cont'd on sheet No. 3

Datasheet No. MY-SK309-66-PR-DS-0002-00


Client : PTTEP Sarawak Oil Limited (993918-P)
PTTEP Sabah Oil Limited (993919-M) Specification No.
PROCESS DATASHEET Equipment No : A-2410A/B
BOOSTER COMPRESSOR PACKAGE Equipment Name : BOOSTER COMPRESSOR PACKAGE
Quantity : TWO (2)
PROCESS DATA

1.0 GENERAL

BOOSTER COMPRESSOR WILL BE INSTALLED TO BOOST THE LP GAS TO 30 barg TO FLOW TO PRODUCTION SEPARATOR, V-2030 WHICH IS OPERATING
AT 22 - 24 BARG.

2.0 PROCESS DESCRIPTION

LP GAS FROM SAND HANDLING SYSTEM ROUTED TO BOOSTER COMPRESSOR PACKAGE WHERE BOOSTER COMPRESSOR PACKAGE TREATS WET GAS
TO REMOVE SOLID PARTICLES CARRIED OVER FROM THE SAND HANDLING SYSTEM AND LIQUID ADEQUATE ENOUGH FOR SMOOTH COMPRESSOR AND
GAS ENGINE OPERATION.

3.0 PROCESS DATA

REFER TO SHEET 4 FOR PROCESS DATA AT THE INLET OF BOOSTER COMPRESSOR SYSTEM.

4.0 SCOPE OF SUPPLY

1. BOOSTER COMPRESSOR TO BE GE DRIVEN TO BE SUPPLED WITH THE PACKAGE.


2. SCOPE OF SUPPLY SHALL CONSIDER :
i) MAJOR EQUIPMENT BUT NOT LIMITED TO:
- 2 x 50% BOOSTER COMPRESSORS
- 2 x 50% COMPRESSOR SUCTION SCRUBBERS
- 2 x 50% AIR COOLERS OR HEAT EXCHANGERS
- 2 x 50% FUEL GAS SCRUBBERS
ii) OTHER SUPPLEMENTARY ITEMS AND FITTINGS/VALVES SUPPLIED BY VENDOR WHICH ARE DEEMED NECESSARY, BUT NOT LIMITED TO THE
FOLLOWING:
- SHUTDOWN / ACTUATED VALVE / BLOWDOWN VALVE
- FLOWMETER
- CONTROL VALVE
- PRESSURE GAUGE
- RELIEF VALVE
iii) INSTRUMENTATION AND CONTROL SYSTEM
iv) ELECTRICAL WIRING (IF REQUIRED)
v) ALL INTERCONNECTING PIPING AND VALVES, ETC.
3. VENDOR TO CONSIDER FUEL GAS CONDITIONING UNIT (FUEL GAS SCRUBBER, FUEL GAS FILTER, FUEL GAS SUPERHEATER (IF REQUIRED)) IN
THE PACKAGE.
4. REFER TO SHEET 6 FOR VENDOR SCOPE DEMARCATION.

CONTRACT TITLE : PROVISION OF ENGINEERING DESIGN


SERVICES FOR PTTEP'S OPERATION

WORK ORDER TITLE : PROVISION OF ENGINEERING WORKS FOR


GOP-B BOOSTER COMPRESSOR 4 25-06-2020 Internal Issue
RNY KBJ KBJ
3 14-05-2020 Internal Issue
RNY KBJ KBJ
WORK ORDER NUMBER : 025B - GOP-B 2 24-04-2020 Internal Issue
RNY KBJ KBJ
1 23-03-2020 Internal Issue
RNY KBJ KBJ
MMC PROJECT NUMBER : MSO-A-0088 0 13-03-2020 Internal Issue
RNY KBJ KBJ
A 29-01-2020 Internal Issue
RNY KBJ KBJ
PREPARED CHECKED APPROVED APPROVED
CONTRACT NO. MURPHY/S18039 REV DATE REVISION DESCRIPTION
: MMC MMC MMC PTTEP
Sheet No 3 cont'd on sheet No. 4
Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W)
Datasheet No. MY-SK309-66-PR-DS-0002-00
Client : PTTEP Sarawak Oil Limited (993918-P)
PTTEP Sabah Oil Limited (993919-M) Specification No.
PROCESS DATASHEET Equipment No : A-2410A/B (NOTE 2, 3, 10, 17, 18, 19)
BOOSTER COMPRESSOR PACKAGE Equipment Name : BOOSTER COMPRESSOR PACKAGE
Quantity : TWO (2)
P&ID No. MY-SK309-66-PR-DW-0002-SHEET 1 & 2 1

TYPE (COMPRESSOR) RECIPROCATING (NOTE 15, 17) 2

DRIVER (COMPRESSOR) GAS ENGINE 3

NUMBER OF STAGES (COMPRESSOR) TWO (2) (NOTE 3) 4


5
PROCESS DATA 6
7

FLUID HYDROCARBON GAS / WATER 8

CORROSIVE / EROSIVE COMPOUNDS SAND PARTICLE & WATER VAPOUR MIXTURE (NOTE 5) 9

MATERIALS OF CONSTRUCTION (NOTE 5) * 10

PACKAGE DESIGN PRESSURE bar (g) (NOTE 26) * 11

PACKAGE DESIGN TEMPERATURE °C * 12


13

CASE (NOTE 1, 4, 6) CASE 1 CASE 2 CASE 3 CASE 4 14

OPERATING CONDITION PACKAGE PACKAGE PACKAGE PACKAGE 15


PACKAGE PACKAGE PACKAGE PACKAGE
INLET INLET INLET INLET
OUTLET OUTLET OUTLET OUTLET 16
(NOTE 11) (NOTE 11) (NOTE 11) (NOTE 11)
TOTAL FLOW (NOTE 9) kg/hr 4760 * 5714 * 5704 * 7492 * 17

VAPOUR FLOW (NOTE 9) kg/hr 4759.7 * 4895.7 * 4956.8 * 4969.7 * 18

(NOTE 9) m³/hr 1840.2 * 1856.3 * 1861.3 * 1874.3 * 19

(NOTE 9) MMscfd 5.04 5.02 ** 5.18 5.03 ** 5.20 5.05 ** 5.21 5.05 ** 20

HC LIQUID FLOW (NOTE 9) kg/hr - - - - - - - - 21

(NOTE 9) m³/hr - - - - - - - - 22

(NOTE 9) bbl/d - - - - - - - - 23

WATER FLOW (NOTE 9) kg/hr - * 818.5 * 747.0 * 2522.6 * 24

(NOTE 9) m³/hr - * 0.828 * 0.756 * 2.555 * 25

(NOTE 9) bbl/d - * 125.03 * 114.10 * 385.76 * 26


27

COMPRESSOR DISCH. PRESSURE (FINAL STAGE)


bar (g) - 30.0 - 30.0 - 30.0 - 30.0 28

BATTERY LIMIT PRESSURE bar (g) 2.7 22.8 2.7 22.8 2.7 22.8 2.7 22.8 29

BATTERY LIMIT TEMPERATURE °C 56.0 (NOTE 22) * 50.2 (NOTE 22) * 50.1 (NOTE 22) * 51.5 (NOTE 22) * 30
31

VAPOUR MOLECULAR WEIGHT - 18.9 * 18.9 * 19.1 * 19.1 * 32

VAPOUR DENSITY kg/m³ 2.59 * 2.64 * 2.66 * 2.65 * 33

VAPOUR VISCOSITY cP 0.0124 * 0.0121 * 0.0121 * 0.0121 * 34

VAPOUR Cp / Cv - 1.268 * 1.272 * 1.269 * 1.269 * 35

VAPOUR Z FACTOR - 0.9923 * 0.9917 * 0.9916 * 0.9917 * 36


37

HC LIQUID DENSITY kg/m³ - - - - - - - - 38

HC LIQUID VISCOSITY cP - - - - - - - - 39

HC LIQUID SURFACE TENSION dyne/cm - - - - - - - - 40


41

WATER DENSITY kg/m³ - * 988.19 * 988.24 * 987.16 * 42

WATER VISCOSITY cP - * 0.5423 * 0.5429 * 0.5304 * 43

WATER SURFACE TENSION dyne/cm - * 67.698 * 67.709 * 67.465 * 44


45
PERFORMANCE 46

COMPRESSION RATIO - * 47

ISENTROPIC EFFICIENCY % 75 * (NOTE 7) 48

ESTIMATED ABSORBED POWER kW 608.8 * (NOTE 7) 613.0 * (NOTE 7) 614.1 * (NOTE 7) 615.6 * (NOTE 7) 49

** EXPECTED OUTPUT TO BE CONFIRMED BY VENDOR. 50


51
52
53
54

55
56
57
58
59
60
61
62
63
64
65
66
CONTRACT TITLE :
PROVISION OF ENGINEERING DESIGN
SERVICES FOR PTTEP'S OPERATION

WORK ORDER TITLE : PROVISION OF ENGINEERING WORKS FOR


GOP-B BOOSTER COMPRESSOR 4 25-06-2020 Internal Issue
RNY KBJ KBJ
3 14-05-2020 Internal Issue
RNY KBJ KBJ
WORK ORDER NUMBER : 025B - GOP-B 2 24-04-2020 Internal Issue
RNY KBJ KBJ
1 23-03-2020 Internal Issue
RNY KBJ KBJ
MMC PROJECT NUMBER : MSO-A-0088 0 13-03-2020 Internal Issue
RNY KBJ KBJ
A 29-01-2020 Internal Issue
RNY KBJ KBJ
PREPARED CHECKED APPROVED APPROVED
CONTRACT NO. : MURPHY/S18039 REV DATE REVISION DESCRIPTION
MMC MMC MMC PTTEP
Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 4 cont'd on sheet No. 5
Datasheet No. MY-SK309-66-PR-DS-0002-00
Client : PTTEP Sarawak Oil Limited (993918-P)
PTTEP Sabah Oil Limited (993919-M) Specification No.
PROCESS DATASHEET Equipment No : A-2410A/B (NOTE 2, 3, 10, 17, 18, 19)
BOOSTER COMPRESSOR PACKAGE Equipment Name : BOOSTER COMPRESSOR PACKAGE
Quantity : TWO (2)
NOTES 1

1. DESIGN CASES AS PER BELOW: 2

CASE 1 : MAXIMUM GAS CASE (YEAR JUNE 2022) 3

CASE 2 : MAXIMUM WATER CASE (YEAR MAY 2026) 4

CASE 3 : MAXIMUM CONDENSATE/ LIQUID CASE (YEAR OCT 2026) 5

CASE 4 : WATER BREAK THROUGH 6

THE PROCESS DATA PROVIDED IN SHEET 4 IS FOR 1 TRAIN. 7

2. DESIGN LIFE SHALL BE 15 YEARS. 8

3. NUMBER OF STAGE TO BE ADVISED BY MECHANICAL / VENDOR. 9

4. GAS COMPOSITION AT THE INLET OF COMPRESSOR PACKAGE, A-2410A/B IS PROVIDED ON SHEET 7 FOR ALL DESIGN CASES. 10

5. REFER TO ATTACHMENT 2 FOR CDBM STUDY RESULT. THE MATERIAL SPECIFIED IS BASED ON CDBM STUDY AND IS A MINIMUM REQUIREMENT, 11

VENDOR TO CONFIRM ON THE RECOMMENDED MATERIAL. 12

6. RECYCLE OPERATION CASES ACCORDING TO PRESSURIZED AND DEPRESSURIZED START-UP SHALL BE CONFIRMED BY VENDOR AND INCLUDED 13

IN VENDOR DATASHEET. 14

7. ESTIMATED ABSORBED POWER IS BASED ON TOTAL DUTY FOR ALL 2 STAGES ON SINGLE SHAFT AND ISENTROPIC EFFICIENCY OF 75%. VENDOR TO 15

CONFIRM POWER DUTY AND ISENTROPIC EFFICIENCY. 16

8. * VENDOR TO ADVISE/ CONFIRM. 17

9. VENDOR TO INCLUDE 10% DESIGN MARGIN ON INLET FLOWRATE. 18

10. THE OVERALL PACKAGE SHALL BE DESIGNED FOR TURNDOWN CAPACITY OF 10% OF DESIGN CAPACITY OF THE DESANDER TRAIN. 19

11. CONDITION / PROPERTIES IS TAKEN AT INLET B/L OF BOOSTER COMPRESSOR PACKAGE, A-2410A/B. 20

12. VENDOR TO CONSIDER APPROPRIATE INTERNALS FOR BOOSTER COMPRESSOR SUCTION SCRUBBERS. LIQUID CARRY OVER IN GAS SHALL BE LESS 21

THAN 0.1 USG/MMscf OR SUITABLE FOR COMPRESSOR SMOOTH OPERATION WHICHEVER IS STRINGENT. THE LIQUID DROPLET PARTICLE SIZES OF 22

10 MICRON AND GREATER SHALL BE REMOVED WITH CONSIDERATION 99.5% - 100% LIQUID REMOVAL EFFICIENCY. VENDOR SHALL CONFIRM THE 23

SEPARATION EFFICIENCY AND PRESSURE DROP OF THE INTERNALS OF SCRUBBERS. 24

13. VENDOR SHALL PROVIDE STANDARD P&IDS OF THE COMPRESSOR AND THE AUXILLARY SYSTEMS ALONG WITH THE BID. 25

14. VENDOR TO PROVIDE THE FOLLOWING UTILITY CONSUMPTIONS AT NORMAL AND PEAK CONSUMPTIONS, AS WELL AS CONTINUOUS AND 26

INTERMITTENT USAGE: 27

A) INSTRUMENT / UTILITY AIR (VENDOR TO ADVISE ANY POSSIBLE TECHNOLOGY IF INSTRUMENT/UTILITY AIR NOT AVAILABLE ON THE PLATFORM) 28

B) VENDOR TO NOTE FOLLOWING UTILITIES NOT AVAILABLE (NO ULLAGE) ON THE PLATFORM. 29

- ELECTRICAL POWER 30

- FUEL GAS 31

C) OTHER UTILITY REQUIREMENT (IF ANY) 32

-MINIMUM REQUIRED UTILITIES WHICH ARE DEEMED NECESSARY FOR RUNNING BOOSTER COMPRESSOR OTHER THAN SPECIFIED ABOVE. 33

15. COMPRESSOR SELECTION SHALL BE ACCORDING TO THE FOLLOWING ORDER OF PRECEDENCE: PTTEP, PTS AND API STANDARDS. 34

16. BOOSTER COMPRESSOR MAY EXPERIENCE SOME SAND AT THE INLET AS SAND HANDLING SYSTEM CAN REMOVE SAND PARTICLES OF 5 MICRONS 35

AND LARGER AT 98% EFFICIENCY AND ANTICIPATE CARRYOVER OF BALANCE SAND. COMPRESSOR SUCTION SCRUBBER SHALL BE DESIGNED TO 36

REMOVE SOLID PARTICLE UP TO SUITABLE MINIMUM REQUIREMENT FOR SMOOTH COMPRESSOR AND GAS ENGINE OPERATION. 37

17. COMPRESSOR SELECTION BY VENDOR. 38

18. VENDOR TO PROVIDE PERFORMANCE GUARANTEE OF THE BOOSTER COMPRESSOR AT THE OUTLET B/L. 39

19. VENDOR TO ADVISE ON SOLID PARTICLE SIZE LIMITATION FOR COMPRESSOR AND GAS ENGINE. REFER TO ATTACHMENT 1 FOR EXPECTED 40

SOLID PARTICLES AT BOOSTER COMPRESSOR B/L INLET. 41

20. ● INSTRUMENT AIR SUPPLY 42

- NOMINAL PRESSURE RANGE : 7.0 - 7.2 BARG ; NORMAL TEMPERATURE : 40 °C 43

- DESIGN PRESSURE : 13.8 BARG ; DESIGN TEMPERATURE (MAX/MIN) : 65 / 0 °C 44

21. - DESIGN PRESSURE / TEMP OF UPSTREAM SYSTEM - 14.6 BARG / 72 °C (FOR INFORMATION) 45

- DESIGN PRESSURE / TEMP OF DOWNSTREAM SYSTEM - 45 BARG / 87 °C (FOR INFORMATION) 46

22. BOOSTER COMPRESSOR DISCHARGE TEMPERATURE AT B/L SHALL NOT EXCEED 72 °C. 47

23. VENDOR TO CONSIDER USE OF FUEL GAS DOWNSTREAM OF SUCTION SCRUBBER WHICH IS AVAILABLE AT PRESSURE APPROXIMATELY 2.4 BARG. 48

VENDOR TO CONSIDER FURTHER TREATMENT (i.e. TO INSTALL FUEL GAS SCRUBBER DOWNSTREAM OF SUCTION SCRUBBER). VENDOR TO NOTE 49

ESTIMATED PRESSURE AVAILABLE AT GAS ENGINE IS APPROXIMATELY 2.1 BARG. 50

24. VENDOR TO INCLUDE BLOW OFF CASE SO AS TO TRANSFER SEPARATED LIQUID BACK TO COMPRESSOR DISCHARGE. 51

25. VENDOR TO PROVIDE INFORMATION BUT NOT LIMITED TO THE FOLLOWING: 52

A) PROCESS FLOW DIAGRAM 53

B) LIST OF UTILITIES, CONSUMPTION (NORMAL & PEAK), ETC 54

C) OPERATING AND CONTROL PHILOSOPHY 55

D) VENDOR TO ADVISE ON PRELIMINARY EQUIPMENT SIZING INSIDE THE PACKAGE 56

E) VENDOR TO ADVISE ON RELIEF AND BLOWDOWN TO BE RELIEVED FROM PACKAGE (IF ANY) 57

F) ANY OTHER INFORMATION INDISE THE SPECIFICATION. 58

26. 14.6 BARG DESIGN PRESSURE FOR ALL IN-LINE PROCESS COMPONENTS (i.e. PIPING, INSTRUMENTS, VESSELS ETC) INSIDE THE COMPRESSOR 59

PACKAGEBEXCEPT FOR 2ND STAGE COMPRESSOR DISCHARGE WHERE ALL THE PROCESS IN-IN PROCESS COMPONENTS SHALL BE DESIGNED 60

AT 45 BARG. 61

27. FLUCTUATION IN THE BOOSTER COMPRESSOR INLET PRESSURE MAY ANTICIPATE DUE TO POTENTIAL OF SLUGGING IN THE VERTICAL PIPE FROM 62

DESANDER TO BOOSTER COMPRESSOR. COMPRESSOR PACKAGE SHALL BE DESIGNED TO CATER FOR FLUCTUATION IN PRESSURE AT 63

COMPRESSOR INLET. 64
4 28. VENDOR TO LIMIT TOTAL BLOWDOWN FROM THE BOOSTER COMPRESSOR PACKAGE UP TO 3500 kg/hr TO AVOID MAJOR MODIFICATION ON 65

THE PLATFORM. 66

29. IF INLET SEPARATOR FILTER IS CARTRIDGE FILTER TYPE THEN IT SHOULD BE 2 x 100% PER TRAIN AND CARTRIDGE FILTER REPLACEMENT SHALL NOT 67

BE LESS THAN 3 MONTHS. 68


69
70

CONTRACT TITLE :
PROVISION OF ENGINEERING DESIGN
SERVICES FOR PTTEP'S OPERATION

WORK ORDER TITLE : PROVISION OF ENGINEERING WORKS FOR GOP-


B BOOSTER COMPRESSOR 4 25-06-2020 Internal Issue RNY KBJ KBJ
3 14-05-2020 Internal Issue RNY KBJ KBJ
WORK ORDER NUMBER : 025B - GOP-B 2 24-04-2020 Internal Issue RNY KBJ KBJ
1 23-03-2020 Internal Issue RNY KBJ KBJ
MMC PROJECT NUMBER : MSO-A-0088 0 13-03-2020 Internal Issue RNY KBJ KBJ
A 29-01-2020 Internal Issue RNY KBJ KBJ
PREPARED CHECKED APPROVED APPROVED
CONTRACT NO. : MURPHY/S18039 REV DATE REVISION DESCRIPTION
MMC MMC MMC PTTEP
Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 5 cont'd on sheet No. 6
Datasheet No. MY-SK309-66-PR-DS-0002-00
Client : PTTEP Sarawak Oil Limited (993918-P)
PTTEP Sabah Oil Limited (993919-M) Specification No.
PROCESS DATASHEET Equipment No : A-2410A/B
BOOSTER COMPRESSOR PACKAGE Equipment Name : BOOSTER COMPRESSOR PACKAGE
Quantity : TWO (2)
SKETCH (TYPICAL)

PRELIMINARY
SCHEMATIC AND
SUBJECT TO FINALIZE
WITH VENDOR

CONTRACT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES


FOR PTTEP'S OPERATION

WORK ORDER TITLE : PROVISION OF ENGINEERING WORKS FOR GOP-B


BOOSTER COMPRESSOR 4 25-06-2020 Internal Issue RNY KBJ KBJ
3 14-05-2020 Internal Issue RNY KBJ KBJ
WORK ORDER NUMBER : 025B - GOP-B 2 24-04-2020 Internal Issue RNY KBJ KBJ
1 23-03-2020 Internal Issue RNY KBJ KBJ
MMC PROJECT NUMBER : MSO-A-0088 0 13-03-2020 Internal Issue RNY KBJ KBJ
A 29-01-2020 Internal Issue RNY KBJ KBJ
PREPARED CHECKED APPROVED APPROVED
CONTRACT NO. : MURPHY/S18039 REV DATE REVISION DESCRIPTION
MMC MMC MMC PTTEP
Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 6 cont'd on sheet No. 7

Datasheet No. MY-SK309-66-PR-DS-0002-00


Client : PTTEP Sarawak Oil Limited (993918-P)
PTTEP Sabah Oil Limited (993919-M) Specification No.
PROCESS DATASHEET Equipment No : A-2410A/B (NOTE 2, 3, 10, 17, 18, 19)
BOOSTER COMPRESSOR PACKAGE Equipment Name : BOOSTER COMPRESSOR PACKAGE
Quantity : TWO (2)
GAS COMPOSITION TO BOOSTER COMPRESSOR 1
2
3

GAS COMPOSITION (MOLE FRACTION) 4

COMPONENT 5
CASE 1 (NOTE 1) CASE 2 (NOTE 1) CASE 3 (NOTE 1) CASE 4 (NOTE 1)
6

Oxygen 0.00000 0.00000 0.00000 0.00000 7

Nitrogen 0.00654 0.00541 0.00547 0.00411 8

Methane 0.88215 0.73031 0.73838 0.55520 9

Carbon Dioxide 0.02356 0.01956 0.01979 0.01496 10

Ethane 0.03810 0.03156 0.03196 0.02404 11

Propane 0.02448 0.02030 0.02068 0.01555 12

i-Butane 0.00452 0.00376 0.00387 0.00291 13

n-Butane 0.00587 0.00489 0.00508 0.00382 14

i-Pentane 0.00192 0.00162 0.00174 0.00131 15

n-Pentane 0.00143 0.00121 0.00132 0.00100 16

Hexanes 0.00125 0.00109 0.00137 0.00103 17

Heptanes 0.00193 0.00183 0.00288 0.00217 18

Octanes 0.00019 0.00020 0.00041 0.00031 19

Nonanes 0.00005 0.00006 0.00015 0.00011 20

Decanes 0.00000 0.00000 0.00000 0.00000 21

Undecanes 0.00000 0.00000 0.00000 0.00000 22

Dodecanes (C12+) 0.00000 0.00000 0.00000 0.00000 23


H2 O 0.00801 0.17819 0.16689 0.37349 24

TOTAL 1.00000 1.00000 1.00000 1.00000 25


26
27

FUEL GAS COMPOSITION (MOLE FRACTION) 28

COMPONENT 29
CASE 1 (NOTE 1) CASE 2 (NOTE 1) CASE 3 (NOTE 1) CASE 4 (NOTE 1)
30

Oxygen 0.00000 0.00000 0.00000 0.00000 31

Nitrogen 0.00654 0.00636 0.00635 0.00633 32

Methane 0.88215 0.85864 0.85644 0.85422 33

Carbon Dioxide 0.02356 0.02300 0.02295 0.02301 34

Ethane 0.03810 0.03710 0.03708 0.03698 35

Propane 0.02448 0.02387 0.02399 0.02393 36

i-Butane 0.00452 0.00442 0.00449 0.00448 37

n-Butane 0.00587 0.00575 0.00589 0.00588 38

i-Pentane 0.00192 0.00190 0.00202 0.00201 39

n-Pentane 0.00143 0.00142 0.00154 0.00153 40

Hexanes 0.00125 0.00128 0.00159 0.00158 41

Heptanes 0.00193 0.00215 0.00334 0.00333 42

Octanes 0.00019 0.00024 0.00048 0.00047 43

Nonanes 0.00005 0.00007 0.00018 0.00018 44

Decanes 0.00000 0.00000 0.00000 0.00000 45

Undecanes 0.00000 0.00000 0.00000 0.00000 46

Dodecanes (C12+) 0.00000 0.00000 0.00000 0.00000 47


H2 O 0.00801 0.03379 0.03369 0.03607 48

TOTAL 1.00000 1.00000 1.00000 1.00000 49


50
51

FUEL GAS CONDITIONS / PROPERTIES 52

COMPONENT 53
CASE 1 (NOTE 1) CASE 2 (NOTE 1) CASE 3 (NOTE 1) CASE 4 (NOTE 1)
54

PRESSURE (barg) 2.70 2.70 2.70 2.70 55

TEMPERATURE (oC) 56.00 50.20 50.13 51.51 56

MOLECULAR WEIGHT 18.92 18.94 19.12 19.12 57

LHV (kJ/kg) 45773.97 44633.12 44638.01 44522.08 58


59
60
61
62
63
64
65
66
67
68
69
70

CONTRACT TITLE :
PROVISION OF ENGINEERING DESIGN
SERVICES FOR PTTEP'S OPERATION

WORK ORDER TITLE : PROVISION OF ENGINEERING WORKS FOR


GOP-B BOOSTER COMPRESSOR 4 25-06-2020 Internal Issue
RNY KBJ KBJ
3 14-05-2020 Internal Issue
RNY KBJ KBJ
WORK ORDER NUMBER : 025B - GOP-B 2 24-04-2020 Internal Issue
RNY KBJ KBJ
1 23-03-2020 Internal Issue
RNY KBJ KBJ
MMC PROJECT NUMBER : MSO-A-0088 0 13-03-2020 Internal Issue
RNY KBJ KBJ
A 29-01-2020 Internal Issue
RNY KBJ KBJ
PREPARED CHECKED APPROVED APPROVED
CONTRACT NO. : MURPHY/S18039 REV DATE REVISION DESCRIPTION
MMC MMC MMC PTTEP
Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 7 cont'd on sheet No. 8
Datasheet No. MY-SK309-66-PR-DS-0002-00
Client : PTTEP Sarawak Oil Limited (993918-P)
PTTEP Sabah Oil Limited (993919-M) Specification No.
ATTACHMENT 1

GOP-B SAND CHARACTERISTICS

AT BOOSTER COMPRESSOR B/L INLET

SHEET 8 OF 9
%DVLV6DQG5DWH 6DQG+DQGOLQJ6\VWHP9HQGRUWR*XDUDQWHH6ROLGVDW2XWOHWRI6DQG+DQGOLQJ
 NJGD\
DWWKHLQOHWRI6DQG+DQGOLQJ6\VWHP 6\VWHP6KDOOQRWH[FHHGVSHFLILHGEHORZ
per train
6ROLGVDW2XWOHWRI6DQG
5HVXOW8QGHU 6DQG
6L]HV 5HVXOW,Q6L]HV 5HVXOW8QGHU 6HSDUDWLRQ(IILFLHQF\DW6DQG +DQGOLQJ6\VWHP 5HVXOW8QGHU
6L]HV &XP 3DUWLFOHV
PLFURQ 9RO 6L]HV &XP +DQGOLQJ6\VWHP ,QOHW%/RI%RRVWHU 6L]HV &XP
9RO NJGD\
&RPSUHVVRU3DFNDJH
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
%DVLV6DQG5DWH 6DQG+DQGOLQJ6\VWHP9HQGRUWR*XDUDQWHH6ROLGVDW2XWOHWRI6DQG+DQGOLQJ
 NJGD\
DWWKHLQOHWRI6DQG+DQGOLQJ6\VWHP 6\VWHP6KDOOQRWH[FHHGVSHFLILHGEHORZ
total sand per train = 7.20 kg/day
6ROLGVDW2XWOHWRI6DQG
5HVXOW8QGHU 6DQG
6L]HV 5HVXOW,Q6L]HV 5HVXOW8QGHU 6HSDUDWLRQ(IILFLHQF\DW6DQG +DQGOLQJ6\VWHP 5HVXOW8QGHU
6L]HV &XP 3DUWLFOHV
PLFURQ 9RO 6L]HV &XP +DQGOLQJ6\VWHP ,QOHW%/RI%RRVWHU 6L]HV &XP
9RO NJGD\
&RPSUHVVRU3DFNDJH
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       
       

6DQGPLFURQDQGVPDOOHU  NJGD\


6DQGEHWZHHQPLFURQ  NJGD\
7RWDO6DQGDWWKH,QOHWRI%RRVWHU
7RWDO6DQGDWWKHLQOHWRI6DQG+DQGOLQJ6\VWHP NJGD\  NJGD\
&RPSUHVVRU

total sand per train = 7.20 kg/day 7KHDERYH'$7$LVVXEMHFWWR6DQG+DQGOLQJ6\VWHPYHQGRUFRQILUPDWLRQ


ATTACHMENT 2

MSD FROM CDBM STUDY

SHEET 9 OF 9
CS + 3 mm CA + CS + 3 mm CA + CS + 3 mm CA +
Internal Coating Internal Coating Internal Coating
below LC below LC below LC

CS
CS LEGEND
Tube: CS Tube: CS
CS + 3 mm CA
CS + 6 mm CA
DSS
Galvanised CS

CS + 3 mm CA +
Internal Coating
PTTEP HK Offshore Limited
PTTEP Sarawak Oil Limited
PTTEP Sabah Oil Limited

WO NO.:25B
PROVISION OF ENGINEERING WORKS FOR GOPB BOOSTER
COMPRESSOR (FEED)

DATASHEET FOR GAS BOOSTER COMPRESSOR


PACKAGE's ALTERNATOR

Consultant:

MMC Oil & Gas Engineering Sdn Bhd

REVISION HISTORY

Rev. Date Description Author Checked Approved

F0 12-June-2020 Approved for Bid RIMR NM / ABS


FA 05-June-2020 Issued for Review RIMR NM / ABS

COUNTRY FIELD/ASSET FACILITY DISCIPLINE DOCUMENT SEQUENCE SHEET`


REVISION
Document CODE CODE CODE CODE TYPE NO. NO.
Number
MY SK309 66 EL DS 0001 00 F0
MY-SK309-66-EL-DS-0001-00
Datasheet for Gas Booster
Compressor Package’s Alternator Revision : F0
Page 2 of 3

REVISION STATUS / SUMMARY OF CHANGES

Revision Revised Paragraphs Revision Reason for Revision


Description
FA - Issued for Review First Issuance

F0 Appendix 1 Approved for Bid Incorporate Comments

DISCLAIMER STATEMENT

The information provided by PTTEP is confidential and shall only be used by the party to whom it is disclosed to (“the Receiving Party”).
The Receiving Party shall not disclose, publish, reproduce or reveal the information received to any other third party whatsoever except
with the specific prior written authorization of PTTEP. The Receiving Party shall within five (5) days from notice from PTTEP return or
destroy (upon instruction of PTTEP) all confidential information furnished by PTTEP.

The Receiving Party shall also take such precautions as are reasonably necessary to protect the confidential information, including taking
measures to prevent loss, theft and misuse. The Receiving Party shall fully indemnify and keep PTTEP at all time fully indemnified from and
against any loss or disclose of confidential information and from all actions, proceedings, claims, demands, costs, awards and damages
arising directly or indirectly as a result of such unauthorized disclosure.
MY-SK309-66-EL-DS-0001-00
Datasheet for Gas Booster
Compressor Package’s Alternator Revision : F0
Page 3 of 3

TABLE OF CONTENT

1.0 APPENDIX (DATASHEET FOR GAS BOOSTER COMPRESSOR PACKAGE’S


ALTERNATOR) .................................................................................................................... 4
MY-SK309-66-EL-DS-0001-00
Datasheet for Gas Booster
Compressor Package’s Alternator Revision : F0
Page 1 of 4

APPENDIX 1
Datasheet for Gas Booster Compressor Package s Alternator
Equipment No : G-XXXX A/B
ELECTRICAL DATASHEET
Equipment Name : GAS BOOSTER COMPRESSOR PACKAGE's ALTERNATOR
GAS BOOSTER COMPRESSOR PACKAGE - COMPRESSOR's ALTERNATOR
Quantity : Two (2) units
DATASHEET IDENTIFICATIONS
DOCUMENT NO MY-SK309-66-EL-DS-0001-00

ADMINISTRATIVE IDENTIFICATIONS
PROJECT NUMBER MSO-A-0088 SUB PROJECT NO WOR-25(B)
PROJECT PROVISION OF ENGINEERING DESIGN SERVICES FOR MURPHY'S OPERATIONS

ENTERPRISE
SITE GO-PB Platform
AREA ZONE 2 CELL UNIT

1. DEVICE IDENTIFICATION
TAG NUMBER G-XXXX A/B
SERVICE GAS BOOSTER COMPRESSOR PACKAGE's ALTERNATOR
P&ID NUMBER

2. PROCESS DATA PROCESS DESIGN CONDITIONS


PROCESS CONDITIONS MINIMUM NORMAL MAXIMUM UNITS
FUEL TYPE VTA VTA VTA
FREQUENCY VTA VTA VTA
FUEL CONSUMPTION :
RATINGS VTA VTA VTA HP
LOAD -2% 50% 2%
US GPH VTA VTA VTA
LUBE OIL CAPACITY PER HOUR VTA VTA VTA
FUEL FLOW :
MAXIMUM FUEL FLOW VTA VTA VTA
MAXIMUM FUEL INLET RESTRICTION VTA VTA VTA
MAXIMUM FUEL INLET TEMPERATURE VTA VTA VTA
AIR :
COMBUSTION AIR VTA VTA VTA
MAXIMUM AIR CLEANER RESTRICTION VTA VTA VTA

ALTITUDE 23300 Above MSL (Note 3) mm


AMBIENT TEMPERATURE (Air Coolers) 20 33.3 35 degree celcius
AMBIENT TEMPERATURE (Other than air coolers) VTA VTA VTA degree celcius
AMBIENT TEMPERATURE INDOOR VTA VTA VTA %
RELATIVE HUMIDITY 13 - 100 %
MAXIMUM WIND VELOCITY 32.1 (3 sec – gust) m/s
COOLING WATER VTA VTA VTA
ATMOSPHERE VTA VTA VTA
ZONE/GAS GROUP VTA VTA VTA
TEMPERATURE CLASSIFICATION VTA VTA VTA

DEVICE SPECIFICATION
3. PACKAGE DATA
RATING VTA
OPERATION Offshore
APPLICATION Continous/Normal Supply
SPEED CONTROL VTA

4. GENERATOR
TYPE OF EXCITATION : MAIN CABLE :
CURRENT BOOST (BRUSHLESS) VTA TYPE NOTE 5
LOCATION CURRENT BOOST TRANSFORMERS VTA SIZE VTA

PREFERRED METHOD OF COOLING: UNBALANCE OF LOAD CURRENT


AIR TO AIR VTA * for LV emergency generator sets only
AIR TO WATER VTA
SELF COOLED OPEN VTA HARMONIC LOAD CURRENT VTA
DEGREE OF PROTECTION AC GENERATOR IP55
TEMPERATURE INDICATION OF GENERATOR AIR : SYSTEM NEUTRAL EARTHING Solidly
AT INLET COOLER VTA BUSDUCT ENTRY N/A
AT OUTLET COOLER VTA CABLE GLANDS NA
GLAND TYPE Metric
TERMINAL BOXES : SPACE OF DIFFERENTIAL PROTECTION CT's N/A
LOCATION MAIN ENTRY BOX VTA ANTI CONDENSATION HEATERS Required
LOCATION START POINT BOX VTA MAX. TEMPERATURE HEATER SURFACE VTA
DIFFERENTIAL PROTECTION CT's NA

PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES


FOR MURPHY'S OPERATIONS
WORK ORDER TITLE : PROVISION OF ENGINEERING WORKS FOR GOP-B
BOOSTER COMPRESSOR (FEED)
WORK ORDER NUMBER : WOR 25(B)
MMCOG PROJECT NUMBER : MSO-A-0088 F0 12-06-2020 Approved For Bid RIMR NM ABS
CONTRACT NO. : MURPHY/S18039 FA 05-06-2020 Issued For Review RIMR NM ABS
PREPARED CHECKED APPROVED APPROVED
REV DATE REVISION DESCRIPTION
MMC MMC MMC PTTEP
ENG. BY : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 1 cont'd on sheet No. 2

Datasheet No. MY-SK309-66-EL-DS-0001-00


CLIENT PTTEP HK Offshore Limited Specification No.MY-SK309-66-ME-SP-0001
:
PTTEP Sarawak Oil Limited
PTTEP Sabah Oil Limited
Equipment No : G-XXXX A/B
ELECTRICAL DATASHEET
Equipment Name : GAS BOOSTER COMPRESSOR PACKAGE's ALTERNATOR
GAS BOOSTER COMPRESSOR PACKAGE - COMPRESSOR's ALTERNATOR
Quantity : Two (2) units
5. CONTROL PANELS
REQUIREMENTS :
ENGINE CONTROL PANEL Yes
GENERATOR CONTROL PANEL Yes
ENGINE AND ALTERNATOR COMBINED IN ONE SKID ENCLOSURE VTA

AVR : ALARMS :
EXECUTION VTA STATOR WINDING TEMPERATURE - HIGH VTA
MANUAL CONTROL SETTING TO FOLLOW VTA AVR FAILURE VTA
AUTOMATIC CONTROL SETTING VTA DIODE FAILURE VTA
LOCATION Alternator Control Panel (ACP) COOLER WATER LEAKAGE (AIR TO WATER COOLING) VTA
DROOP CT LOCATION VTA COOLER AIR OUTLET TEMPERATURE - HIGH VTA
RHEOSTAT LOCATION VTA BEARING TEMPERATURE - HIGH VTA
STEADY STATE VOLTAGE ADJUSTER VTA CONTROL PANEL GENERAL VTA
AUTOMATIC POWER FACTOR CONTROLLER VTA LOCK-OUT GENERAL VTA
POWER FACTOR SUPERVISION VTA
SYNCHRONISING EQUIPMENT VTA METERING :
kWh METER VTA
PROTECTION : EXCITER CURRENT METER VTA
EXCITER VOLTAGE METER VTA
OVER CURRENT - VOLTAGE RESTRAINT YES CONTROL PANEL SUPPLY VOLTAGE METER VTA
STATOR EARTH FAULT VTA
DIFFERENTIAL VTA CONSTRUCTION CONTROL PANEL :
UNDER VOLTAGE YES ENCLOSURE Frame Mounted
OVER VOLTAGE YES CABLE TYPES NOTE 5
UNDER FREQUENCY YES CABLE ENTRIES Bottom
OVER FREQUENCY YES CABLE GLANDS VTA
REVERSE POWER YES GLANDS TYPES Metric
NEGATIVE PHASE SEQUENCE VTA DEGREE OF PROTECTION IP56
LOSS OF EXCITATION VTA ANTI CONDENSATION HEATERS 240V AC, 1PH, 50Hz
STARTOR WINDING TEMPERATURE VTA MAX. TEMPERATURE OF HEATER SURFACE VTA
DIODE FAILURE ` RAIN CANOPY YES
ROTOR EARTH FAULT VTA
BEARING TEMPERATURE VTA
LOCAL ESD VTA
REMOTE ESD VTA

6. ENGINE
MANUFACTURER VTA RATED SPEED VTA
MODEL NUMBER VTA PISTON SPEED VTA
CONFIGURATION VTA COMPRESSION RATIO VTA
ASPIRATION VTA LUBE OIL CAPACITY VTA
GROSS ENGINE POWER OUTPUT VTA OVERSPEED LIMIT VTA
BMEP AT SET RATED LOAD VTA REGENERATIVE POWER VTA
BORE VTA GOVERNOR TYPE Turbocharge
STROKE VTA STARTING VOLTAGE 24V DC

7. EXHAUST
STANDBY RATING VTA STANDBY RATING VTA
EXHAUST GAS FLOW AT SET RATED LOAD MAXIMUM EXHAUST BACK PRESSURE
PRIME RATING VTA PRIME RATING VTA
STANDBY RATING VTA
EXHAUST GAS TEMPERATURE
PRIME RATING VTA

8. STANDARD SET-MOUNTED RADIATOR COOLING


AMBIENT DESIGN VTA STANDBY RATING VTA
TOTAL HEAT REJECTION
FAN LOAD VTA PRIME RATING VTA
VTA MAXIMUM COOLING AIR FLOW STATIC VTA
COOLANT CAPACITY (WITH RADIATOR)
VTA RESTRICTION VTA
COOLING SYSTEM AIR FLOW VTA
VTA
9. ALTERNATOR DATA
CONNECTION STAR VOLTAGE VTA
TEMPERATURE RISE DEGREES Class B DEGREE OF PROTECTION ENCLOSURE IP55
INSULATION CLASS Class F
DUTY Continous
Alternator VTA

10. COMPONENT DESIGN CRITERIA


COMPONENT TYPE VTA

PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES FOR


MURPHY'S OPERATIONS
WORK ORDER TITLE : PROVISION OF ENGINEERING WORKS FOR GOP-B
BOOSTER COMPRESSOR (FEED)
WORK ORDER NUMBER : WOR 25(B)
MMCOG PROJECT NUMBER : MSO-A-0088 F0 12-06-2020 Approved For Bid RIMR NM ABS
CONTRACT NO. : MURPHY/S18039 FA 05-06-2020 Issued For Review RIMR NM ABS
PREPARED CHECKED APPROVED APPROVED
REV DATE REVISION DESCRIPTION
MMC MMC MMC PTTEP
ENG. BY : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 2 cont'd on sheet No. 3

Datasheet No. MY-SK309-66-EL-DS-0001-00


CLIENT : PTTEP HK Offshore Limited Specification No. MY-SK309-66-ME-SP-0001
PTTEP Sarawak Oil Limited
PTTEP Sabah Oil Limited
Equipment No : G-XXXX A/B
ELECTRICAL DATASHEET
Equipment Name : GAS BOOSTER COMPRESSOR PACKAGE's ALTERNATOR
GAS BOOSTER COMPRESSOR PACKAGE - COMPRESSOR's ALTERNATOR
Quantity : Two (2) units
DEVICE SPECIFICATION
11. MATERIAL PROPERTIES
ENCLOSURE MATERIAL (FOR CONTROL PANEL) SS316L

12. PERFORMANCE CHARACTERISTICS


VOLTAGE VARIATIONS +/- 5% Steady State TIME BETWEEN MAJOR OVERHAULS VTA
RATING LARGEST DIRECT ON LINE STARTED MOTOR VTA OVERALL VIBRATION SEVERITY VTA
NOISE LIMITATIONS 85dB (A) CRITICAL SPEEDS VTA
ROOM VENTILATION VTA
ACOUSTIC ENCLOSURE VTA

13. ACCESSORIES

14. SPECIAL REQUIREMENTS


COMPLIANCE STANDARD VTA SPECIFICATION SHEET:
MATERIAL CERTIFICATION VTA NOISE DATASHEET VTA
NACE REQUIREMENT VTA AIRFLOW DATASHEET VTA
ENVIRONMENTAL REQUIREMENT VTA DERATE DATASHEET VTA
TRANSIENT DATASHEET VTA

15. PHYSICAL DATA


WxDxH MASSES MAX TOTALL MASS VTA
SKID VTA VTA PAINT SPECIFICATION FOR REVIEW VTA
COOLER ASSEMBLY VTA VTA PRESERVATION PERIOD VTA
CONTROL PANELS TOTAL VTA VTA SPREADER BAR REQUIRED VTA
DIMENSIONS : WEIGHT :
LENGTH VTA OPEN VTA
UNIT DRY WEIGHT
STANDARD OPEN SET DIMENSIONS WIDTH VTA ENCLOSED VTA
HEIGHT VTA OPEN VTA
UNIT WET WEIGHT
LENGTH VTA ENCLOSED VTA
ENCLOSED SET STANDARD DIMENSIONS WIDTH VTA
HEIGHT VTA

16. CALIBRATIONS AND TEST


TAG NUMBER TEST YES NO WITNESSED
INDIVIDUAL MAIN COMPONENTS VTA VTA VTA
COMPLETE PACKAGE VTA VTA VTA
SPECIAL TEST (SPECIFIC SEPARATELY) VTA VTA VTA
DIRECT ON LINE MOTOR STARTING VTA VTA VTA

17. COMPONENT IDENTIFICATIONS


COMPONENT TYPE VTA
MANUFACTURER NAME VTA
MANUFACTURER COUNTRY VTA
MANUFACTURER CONTACT (E-MAIL) VTA
MANUFACTURER HOMEPAGE VTA
MANUFACTURER DATE VTA
MODEL NUMBER VTA
MANUFACTURER PART NUMBER VTA
SERIAL NUMBER VTA
PURCHASE ORDER VTA

18. SCHEMATIC DIAGRAM

19. NOTES
(1) Describe deviations in tender
(2) Describe additional information required in tender
(3). MSL = Mean Sea Level
(4). VTA = Vendor to advise and complete the datasheet
(5). All power and control cables shall be stranded copper conductor, Cross Linked Polyethylene (XLPE) insulated with Steel Wire Braided (SWB) (for cable 10mm2 and below) or
Armored (SWA) (for cable size 16mm2 and above), inner sheated (bedding) and outer sheath shall be Low Smoke Zero Halogen type complying with IEC 60754-2.
PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES
FOR MURPHY'S OPERATIONS
WORK ORDER TITLE : PROVISION OF ENGINEERING WORKS FOR GOP-B
BOOSTER COMPRESSOR (FEED)
WORK ORDER NUMBER : WOR 25(B)
MMCOG PROJECT NUMBER : MSO-A-0088 F0 12-06-2020 Approved For Bid RIMR NM ABS
CONTRACT NO. : MURPHY/S18039 FA 05-06-2020 Issued For Review RIMR NM ABS
PREPARED CHECKED APPROVED APPROVED
REV DATE REVISION DESCRIPTION
MMC MMC MMC PTTEP
ENG. BY : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 3 cont'd on sheet No. -

Datasheet No. MY-SK309-66-EL-DS-0001-00


CLIENT : PTTEP HK Offshore Limited Specification No.MY-SK309-66-ME-SP-0001
PTTEP Sarawak Oil Limited
PTTEP Sabah Oil Limited
PTTEP HK Offshore Limited
PTTEP Sarawak Oil Limited
PTTEP Sabah Oil Limited

WO NO.:25B
PROVISION OF ENGINEERING WORKS FOR GOPB BOOSTER
COMPRESSOR (FEED)

DATASHEET FOR LV SWITCHRACK

Consultant:

MMC Oil & Gas Engineering Sdn Bhd

REVISION HISTORY

Rev. Date Description Author Checked Approved

ABS
F0 12-June-2020 Approved for Bid MFB NM / ABS
FA 11-June-2020 Issued for Review MFB NM / ABS

COUNTRY FIELD/ASSET FACILITY DISCIPLINE DOCUMENT SEQUENCE SHEET`


REVISION
Document CODE CODE CODE CODE TYPE NO. NO.
Number
MY SK309 66 EL DS 0002 00 F0
MY-SK309-66-EL-DS-0002-00
Datasheet for LV Switchrack Revision : F0
Page 2 of 3

REVISION STATUS / SUMMARY OF CHANGES

Revision Revised Paragraphs Revision Reason for Revision


Description
FA - Issued for Review First Issuance

F0 - Approved for Bid Final Issuance

DISCLAIMER STATEMENT

The information provided by PTTEP is confidential and shall only be used by the party to whom it is disclosed to (“the Receiving Party”).
The Receiving Party shall not disclose, publish, reproduce or reveal the information received to any other third party whatsoever except
with the specific prior written authorization of PTTEP. The Receiving Party shall within five (5) days from notice from PTTEP return or
destroy (upon instruction of PTTEP) all confidential information furnished by PTTEP.

The Receiving Party shall also take such precautions as are reasonably necessary to protect the confidential information, including taking
measures to prevent loss, theft and misuse. The Receiving Party shall fully indemnify and keep PTTEP at all time fully indemnified from and
against any loss or disclose of confidential information and from all actions, proceedings, claims, demands, costs, awards and damages
arising directly or indirectly as a result of such unauthorized disclosure.
MY-SK309-66-EL-DS-0002-00
Datasheet for LV Switchrack Revision : F0
Page 3 of 3

TABLE OF CONTENT

1.0 APPENDIX (DATASHEET FOR LV SWITCHRACK) ................................................. 4


MY-SK309-66-EL-DS-0002-00
Datasheet for LV Switchrack Revision : F0
Page 1 of 1

APPENDIX 1
Datasheet for LV Switchrack
DATASHEET
Equipment No : GOPB-SB-XXXX

415V LV SWITCHRACK Equipment Name : 415V LV SWITCHRACK

Quantity : 2 UNITS

1 DATASHEET IDENTIFICATIONS
2 DOCUMENT NO MY-SK309-66-EL-DS-0002-00
3
4 ADMINISTRATIVE IDENTIFICATIONS
5 PROJECT NUMBER MSO-A-0088 SUB PROJECT NO WO 25B
6 WORK ORDER NAME PROVISION OF ENGINEERING WORKS FOR GOPB BOOSTER COMPRESSOR (FEED)
7 SITE GOPB PLATFORM
8 AREA ZONE 2 CELL UNIT 2 NOS
9
10 1. DEVICE IDENTIFICATION
11 TAG NUMBER GOPB-SB-XXXX
12 SERVICE LOW VOLTAGE SWITCHRACK
13
14 2. PROCESS DATA PROCESS DESIGN CONDITIONS
15 TYPE HV LV
16 PROCESS CONDITIONS MINIMUM NORMAL MAXIMUM UNITS MINIMUM NORMAL MAXIMUM UNITS
17 AMBIENT OPERATING TEMPERATURE 20 35 degree Celcius
18 AMBIENT OPERATING HUMIDITY 13 100 %
19 RATED VOLTAGE 415 V
20 HIGHEST VOLTAGE ±5 %
21 RATED CURRENT (VTA) A
22 PHASE BUSBAR (VTA) A
23 NEUTRAL BUSBAR (VTA) A
24 RATED FREQUENCY 50 Hz
25 RATED POWER FREQUENCY WITHSTAND VOLTAGE FOR 1 (VTA) kV
26 MIN
27 RATED IMPULSE WITHSTAND VOLTAGE (VTA) kV
28 RATED INSULATION VOLTAGE (VTA) kV
29 RATED SHORT-TIME WITHSTAND CURRENT, 1s (VTA) kA
30 RATED SHORT-TIME WITHSTAND CURRENT, 3s (VTA) kA
31 RATED PEAK WITHSTAND CURRENT (VTA) kA
32 MOUNTING FRAME MOUNTED
33 EXTERNAL DIMENSION (VTA) (w) x (l) x (h) mm
34 INTERNAL DIMENSION (VTA)
35 MAXIMUM INCOMING CABLE SIZE (VTA)
36 DEVICE SPECIFICATION
37 3. CIRCUIT BREAKERS
38 TYPE HV LV
39 RATED SHORT CIRCUIT MAKING CURRENT (VTA)
40 RATED AC COMPONENT SHORT CIRCUIT BREAKING (VTA)
41 RATED TRANSIENT RECOVERY VOLTAGE (VTA)
42
TRV PEAK VALUE FOR TERMINAL FAULTS AT RATED SHORT CIRCUIT BREAKING CURRENT (VTA)
43
44 TIME DELAY (VTA)
45 VOLTAGE CO-ORDINATE (VTA)
46 TIME CO-ORDINATE (VTA)
47 RATE OF RISE (VTA)
48 FIRST-POLE-TO-CLEAR FACTOR (VTA)
49 RATED POWER FREQUENCY RECOVERY VOLTAGE (VTA)
50 SMALL INDUCTIVE BREAKING RATED SMALL INDUCTION BREAKING CURRENT (VTA)
51 CURRENT MAX. INSTANTANEOUS VALUE OF CURRENT (VTA)
52 CABLE-CHARGING BREAKING RATED CABLE-CHARGING BREAKING CURRENT (VTA)
53 CURRENT TRV WHEN
MAXIMUM MAX. INSTANTANEOUS VALUE OF CURRENT (VTA)
54 BREAKING CABLE-CHARGING ON SUPPLY SIDE (CIRCUIT BREAKER) (VTA)
55 CURRENT UP TO RATED ON LOAD SIDE (CIRCUIT BREAKER) (VTA)
56 OPENING TIME (VTA)
57 MAXIMUM ARCHING TIME (VTA)
58 RATED MAXIMUM TOTAL BREAK TIME (VTA)
59 CLOSING TIME (VTA)
60 RATED NORMAL CURRENT (VTA)
61 VOLTAGE DROP ACROSS TERMINAL OF A POLE AT RATED NOMINAL CURRENT (VTA)
62 LENGTH OF EACH BREAK (VTA)
63 RATING REQUIRED
(NOTE 2)
64 TYPE OF CIRCUIT BREAKER MOULDED CASE CIRCUIT BREAKER (MCCB)
65 VACUUM INTERRUPTOR (VTA)
66 NUMBER OF BREAKS PER POLE (VTA)
67 LENGTH OF EACH BREAK (VTA)
68 MATERIAL OF CURRENT CARRYING CONDUCTORS (VTA)
69 TYPE OF MAIN CURRENT CONTACT/ MATERIAL (VTA)
70 TYPE OF ARCHING CONTACTS/ MATERIAL (VTA)
71 TYPE OF ARCHING CONTROL DEVICES (VTA)
72
THICKNESS OF VACUUM CIRCUIT BREAKERS SHELL CIRCUIT BREAKER POLE CHAMBER (VTA)
73
74 ON CIRCUIT BREAKER (VTA)
TYPE OF ISOLATING
75 CONTACTS ON FIXED PORTION (VTA)
76 MATERIAL OF CONTACTS (VTA)
77 SERVICE POSITION (VTA)
78 DISCONNECTED POSITION (VTA)
79 CIRCUIT BREAKER LOCATION TEST POSITION (VTA)
80 MAINTENANCE POSITION (VTA)
81 CIRCUIT EARTH POSITION (VTA)
82
83 4. CONSTRUCTION DATA
84 TYPE HV LV
85 APPLICABLE LOCAL STANDARD IEC 60947, IEC 61439
86 SYSTEM VOLTAGE 415 V
87 SYSTEM FREQUENCY 50 Hz
PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES FOR MURPHY'S OPERATIONS

WORK ORDER TITLE : PROVISION OF ENGINEERING WORKS FOR GOPB BOOSTER COMPRESSOR
(FEED)

WORK ORDER NUMBER : WO 25B

MMCOG PROJECT NUMBER : MSO-A-0088


F0 12.06.20 APPROVED FOR BID MFB NM
ABS
ABS
CONTRACT NO. : MURPHY/S18039 FA 11.06.20 ISSUED FOR REVIEW MFB NM ABS
CHECKED
REV DATE REVISION DESCRIPTION PREPARED MMC APPROVED MMC APPROVED PTTEP
MMC
Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 1 cont'd on sheet No. 3
Datasheet No.
MY-SK309-66-EL-DS-0002-00

Client : PTTEP HK Offshore Limited Specification No.

: PTTEP Sarawak Oil Limited MY-SK309-66-ME-SP-0001-00


: PTTEP Sabah Oil Limited

Page 1 of 3
DATASHEET Equipment No : GOPB-SB-XXXX

415V LV SWITCHRACK Equipment Name : 415V LV SWITCHRACK

Quantity : 2 UNITS

88 SERVICE CONDITIONS OUTDOOR


89 SPECIAL SERVICE CONDITIONS OFFSHORE SALT LADEN MARINE ENVIRONMENT
90 SPECIAL TRANSPORT CONDITIONS (VTA)
91 UNIT CONDENSATION HEATERS REQUIRED YES
92 TYPE OF ENCLOSURE STAINLESS STEEL SS316L
93 TYPE OF BREAKER VOLTAGE FREQUENCY DRIVE (VFD) (NOTE 2)
94 RATED CURRENT (VTA)
95 MANUFACTURER (VTA)
OUTGOING FEEDER
96 NUMBER OF CIRCUITS (INCLUSIVE OF SPARES) (VTA)
(MOTOR STARTER)
97 LOCATION/ ENCLOSURE PROTECTION ZONE 2/ Ex 'de'/ IP 56
98 SPARE SPACE CAPACITY (VTA)
99 OUTGOING CABLE TYPE/ CABLE SIZE/ ENTRY SIZE (VTA)
100 FRAMEWORK REQUIRED (VTA)
101 TYPE OF FUSES HBC
102 SUPPLY TRANSFORMERS (VTA)
103 INCOMING BOTTOM
CABLE ENTRY
104 OUTGOING BOTTOM
105 SYSTEM NEUTRAL SOLIDLY EARTHED
106 EARTHING SYSTEM TN-S
107 NUMBER OF SECTION 1
108 CLOSING (VTA)
109 CONTROL VOLTAGE TRIPPING (VTA)
110 CONTACTORS (VTA)
111 CABLE GLAND PLATE PRE-DRILLED, METALLIC (NOTE 2)
112 GLANDS REQUIRED BY PURCHASER/CONTRACTOR
113 GLANDS TYPE ELECTROLESS NICKLE-PLATED BRASS
114 DEGREE OF PROTECTION (CABLE GLAND) IP 66
115 DEGREE OF PROTECTION (SWITCHRACK) IP 56
116 RAIN CANOPY (VTA)
117 ENCLOSURE PROTECTION Ex 'de'
118 EXPLOSION / FIRE HAZARDOUS MATERIAL CLASS (VTA)
119 SURFACE TREATMENT (VTA)
120 PROTECTIVE COATING / COLOUR (VTA)
121 MECHANICAL SHOCK RESISTANCE YES
122 TROPICALIZATION YES
123 AMBIENT STORAGE TEMPERATURE 35 DEGREE CELCIUS
124 FINISHING (VTA)
125
126 5. EARTHING DEVICES
127 TYPE HV LV
128 RATED SHORT CIRCUIT MAKING CURRENT (VTA)
129 RATED PEAK SHORT CIRCUIT CURRENT (VTA)
130 EARTHING FACILITIES EARTHING OF CIRCUITS (VTA)
131 PROVIDED EARTHING OF BUSBAR (VTA)
132 THROUGH CIRCUIT BREAKER (VTA)
METHOD OF EARTHING
133 WHETHER INTEGRAL EARTHING (VTA)
134
135 6. BUSBARS AND CONNECTORS
136 TYPE HV LV
137 RATED NORMAL CURRENT (VTA)
138 CIRCUIT CONNECTORS SOLID BARS
139 MATERIAL HARD DRAWN, HIGH CONDUCTIVITY, TINNED ANNEALED COPPER
140 MAIN BUSBAR (VTA)
CROSS-SECTIONAL AREA
141 CONNECTORS (VTA)
142
143 7. INSULATION
144 TYPE HV LV
145 MINIMUM CLEARANCE OF ANY CIRCUIT BREAKER (VTA)
146 LIVE PARTS w/o INSULATING BETWEEN PHASE (VTA)
147 MATERIAL
LIVE PART TO EARTH (VTA)
148 BUSBARS (VTA)
149 BUSBARS TO CIRCUIT BREAKER (VTA)
150 CIRCUIT BREAKER ISOLATING CONTACT ORIFICE (VTA)
TYPE OF SOLID INSULATING
151 CIRCUIT BREAKER TO CABLE BOX CONNECTORS (VTA)
MATERIAL FOR
152 CIRCUIT BREAKER CONTACT ARMS (VTA)
153 CURRENT TRANSFORMERS (VTA)
154 VOLTAGE TRANSFORMER (VTA)
155
156 8. DURABILITY
157 TYPE HV LV
158 OPERATING DESIGN LIFE 15 YEARS
159 CONTACT LIFE AT RATED INTERRUPTING CAPACITY (VTA)
160 TYPE OF POWER CLOSING DEVICES (VTA)
161 METHOD OF OPENING DEVICES (VTA)
162 TIME REQUIRED TO CHARGE SPRING IN A SPRING CLOSED BREAKER (VTA)
163 9. CABLE TERMINATION
164 TYPE HV LV
165 TYPE OF CABLE TERMINATION (VTA)
166 CABLE GLAND PLATES PROVIDED BY VENDOR
167 10. VOLTAGE TRANSFORMER
168 TYPE HV LV
169 TYPE OF CORE MATERIAL COPPER
170 HIGHEST WORKING VOLTAGE 415 V ±5 %
171 RATED VOLTAGE FACTOR (VTA)
172 3 PHASE OR SINGLE PHASE VTS PROVIDED REQUIRED YES
173 PRIMARY OF VTS PROTECTED WITH FUSE LINKS YES
174 VTS INSTALLED ON LOAD SIDE OF CIRCUIT BREAKER YES
PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES FOR MURPHY'S OPERATIONS

WORK ORDER TITLE : PROVISION OF ENGINEERING WORKS FOR GOPB BOOSTER COMPRESSOR
(FEED)

WORK ORDER NUMBER : WO 25B

MMCOG PROJECT NUMBER : MSO-A-0088


F0 12.06.20 APPROVED FOR BID MFB NM
ABS
ABS
CONTRACT NO. : MURPHY/S18039 FA 11.06.20 ISSUED FOR REVIEW MFB NM ABS
CHECKED
REV DATE REVISION DESCRIPTION PREPARED MMC APPROVED MMC APPROVED PTTEP
MMC
Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 2 cont'd on sheet No. 3
Datasheet No.
MY-SK309-66-EL-DS-0002-00

Client : PTTEP HK Offshore Limited Specification No.

: PTTEP Sarawak Oil Limited MY-SK309-66-ME-SP-0001-00


: PTTEP Sabah Oil Limited

Page 2 of 3
DATASHEET Equipment No : GOPB-SB-XXXX

415V LV SWITCHRACK Equipment Name : 415V LV SWITCHRACK

Quantity : 2 UNITS

175 11. NEON INDICATION


176 TYPE HV LV
177 TYPE OF NEON POTENTIAL INDICATORS LED
178
179 12. SWITCHGEAR METAL ENCLOSURE
180 TYPE HV LV
181 THICKNESS OF ENCLOSURE METAL PANELS MIN 2.5mm
182
183 13. EARTHING BARS
184 TYPE HV LV
185 CROSS SECTIONAL AREA OF COPPER MAIN EARTH BAR FOR SWITCHRACK (VTA)
186 CROSS SECTIONAL AREA OF COPPER SUBSIDIARY (VTA)
187
188 14. LOCKS AND LOCKING FACILITIES
189 TYPE HV LV
190 LOCKING FACILITIES PROVIDED : BY VENDOR
191 SHUTTER ON THE BUSBAR ORIFICE YES
192 SHUTTER ON THE CIRCUIT ORIFICE YES
193 CIRCUIT BREAKER IN ITS SERVICE POSITION (OFF) YES
194 CIRCUIT BREAKER IN ITS EARTH POSITION
195
196 15. COMPONENT DESIGN CRITERIA
197 COMPONENT TYPE (VTA) BUSBAR ARRANGEMENT SINGLE
198 INCOMING BREAKER TYPE 4 POLE, MCCB RED (L1), YELLOW (L2), BLUE (L3)
BUSBAR COLOR CODE
199 PROTECTION RELAY TYPE N/A GREEN W/ YELLOW STRIPES (EARTH)
200 CONTACTOR TYPE N/A SWITCHRACK ARRANGEMENT SINGLE FRONT
201 DEGREE OF POLLUTION 3
202 OVERVOLTAGE CATEGORY IV
203 BUSBAR FULLY INSULATED YES
204
205 16. MATERIAL PROPERTIES
206 *
207
208
209 17. PERFORMANCE CHARACTERISTICS
210 CIRCUIT BREAKER UTILIZATION BREAKER (VTA)
211 MOTOR STARTER AND CONTACTOR RATED DUTY (VTA)
212 MOTOR STARTER COORDINATION TYPE (VTA)
213 CONTACTOR UTILIZATION CATEGORY (VTA)
214
215 18. ACCESSORIES
216 LIFTING LUGS FOR LV SWITCHRACK YES TESTING EQUIPMENT YES
217 BREAKER HANDLING/LIFTING TROLLEY YES
218 BREAKER OPERATING HANDLES YES
219 DEVICE OPERATING KEYS YES
220 INTERLOCK SAFETY KEYS YES
221 19. SPECIAL REQUIREMENTS
222 COMPLIANCE STANDARD IEC 60947, IEC 61439 ENCLOSURE (VTA)
223 MATERIAL CERTIFICATION REQUIRED CIRCUIT BREAKER (VTA)
224 NACE REQUIREMENT REQUIRED CURRENT TRANSFORMERS IEC 61869
225 ENVIRONMENTAL REQUIREMENT (VTA) VOLTAGE TRANSFORMERS IEC 61869
226
227 20. PHYSICAL DATA
228 DIMENSIONS : WEIGHT :
229 WIDTH (mm) (VTA) CUBICLE WEIGHT (VTA)
230 DEPTH (mm) (VTA) WEIGHT WITH ACB (VTA)
231 HEIGHT (mm) (VTA)
232
233
234 21. CALIBRATIONS AND TEST
235 TAG NUMBER TEST WITNESSED
236 S-S41002 INSPECTION YES
237 TYPE TEST YES
238 ROUTINE TEST YES
239 TEST REPORT YES
240
241 22. COMPONENT IDENTIFICATIONS
242 COMPONENT TYPE REQUIRED
243 MANUFACTURER NAME REQUIRED
244 MANUFACTURER COUNTRY REQUIRED
245 MANUFACTURER CONTACT (E-MAIL)
246 MANUFACTURER HOMEPAGE
247 MANUFACTURER DATE REQUIRED
248 MODEL NUMBER REQUIRED
249 MANUFACTURER PART NUMBER REQUIRED
250 SERIAL NUMBER REQUIRED
251 PURCHASE ORDER REQUIRED
252
253
254
255 23. NOTES
256 * 1. VTA = VENDOR TO ADVISE
257 * 2. TO BE CONFIRM BY VENDOR
258 * 3. VENDOR TO COMPLETELY FILL-UP THIS DATASHEET
259 * 4. THE DESIGN TEMPERATURE AND HUMIDITY FOR LV SWITCHRACK SHALL BE 40 DEGREE CELCIUS AND 100% RESPECTIVELY.
260 * 5. VENDOR SHALL COMPLY TO COMPANY SPECIFICATION FOR ELECTRICAL EQUIPMENT FOR PACKAGE UNIT - MOM-SK311-91-EL-SP-0008-00 AS REQUIRED.

PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES FOR MURPHY'S OPERATIONS

WORK ORDER TITLE : PROVISION OF ENGINEERING WORKS FOR GOPB BOOSTER COMPRESSOR
(FEED)

WORK ORDER NUMBER : WO 25B

MMCOG PROJECT NUMBER : MSO-A-0088


F0 12.06.20 APPROVED FOR BID MFB NM
ABS
ABS
CONTRACT NO. : MURPHY/S18039 FA 11.06.20 ISSUED FOR REVIEW MFB NM ABS
CHECKED
REV DATE REVISION DESCRIPTION PREPARED MMC APPROVED MMC APPROVED PTTEP
MMC
Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 3 cont'd on sheet No. 3
Datasheet No.
MY-SK309-66-EL-DS-0002-00

Client : PTTEP HK Offshore Limited Specification No.

: PTTEP Sarawak Oil Limited MY-SK309-66-ME-SP-0001-00


: PTTEP Sabah Oil Limited

Page 3 of 3
PTTEP HK Offshore Limited
PTTEP Sarawak Oil Limited
PTTEP Sabah Oil Limited

WO NO.:25B
PROVISION OF ENGINEERING WORKS FOR GOPB BOOSTER
COMPRESSOR (FEED)

DATASHEET FOR COOLING PUMP MOTOR

Consultant:

MMC Oil & Gas Engineering Sdn Bhd

REVISION HISTORY

Rev. Date Description Author Checked Approved

ABS
F0 12-June-2020 Approved for Bid NAA NM / ABS
FA 11-June-2020 Issued for Review NAA NM / ABS

COUNTRY FIELD/ASSET FACILITY DISCIPLINE DOCUMENT SEQUENCE SHEET`


REVISION
Document CODE CODE CODE CODE TYPE NO. NO.
Number
MY SK309 66 EL DS 0003 00 F0
MY-SK309-66-EL-DS-0003-00
Datasheet for Cooling Pump Motor Revision : F0
Page 2 of 3

REVISION STATUS / SUMMARY OF CHANGES

Revision Revised Paragraphs Revision Reason for Revision


Description
FA - Issued for Review First Issuance

F0 - Approved for Bid Final Issuance

DISCLAIMER STATEMENT

The information provided by PTTEP is confidential and shall only be used by the party to whom it is disclosed to (“the Receiving Party”).
The Receiving Party shall not disclose, publish, reproduce or reveal the information received to any other third party whatsoever except
with the specific prior written authorization of PTTEP. The Receiving Party shall within five (5) days from notice from PTTEP return or
destroy (upon instruction of PTTEP) all confidential information furnished by PTTEP.

The Receiving Party shall also take such precautions as are reasonably necessary to protect the confidential information, including taking
measures to prevent loss, theft and misuse. The Receiving Party shall fully indemnify and keep PTTEP at all time fully indemnified from and
against any loss or disclose of confidential information and from all actions, proceedings, claims, demands, costs, awards and damages
arising directly or indirectly as a result of such unauthorized disclosure.
MY-SK309-66-EL-DS-0003-00
Datasheet for Cooling Pump Motor Revision : F0
Page 3 of 3

TABLE OF CONTENT

1.0 APPENDIX (DATASHEET FOR COOLING PUMP MOTOR) ..................................... 4


MY-SK309-66-EL-DS-0003-00
Datasheet for Cooling Pump Motor Revision : F0
Page 1 of 5

APPENDIX 1
Datasheet for Cooling Pump Motor
ELECTRICAL DATASHEET Equipment No : P-XXXX
GAS BOOSTER COMPRESSOR PACKAGE - COOLING PUMP MOTOR Equipment Name : COOLING PUMP MOTOR FOR GAS BOOSTER COMPRESSOR
PACKAGE
Quantity : TWO (2) x 100%
REQUIREMENTS AND CONDITIONS
GENERAL BASIC REQUIREMENT
(NOTE 5)
Specific requirements : IEC 60034 Rating : (NOTE 1) kW
Unit transformer included : No Speed : (NOTE 1) r/min
(NOTE 1)
Pre-manufacturing meeting : Yes Voltage / Frequency Tolerence : +5% -2% Volt, ±5% Freq
Standards : IEC (IEC 60034-1 Fig. 12)
(NOTE 1)
Certifying authority : BASEEFA / CENELEC / UL Transient Voltage / Frequency Tolerance : +10% -20% Volt, ±5% Freq
o
Design Temperature : 40 C
(NOTE 1)
SITE CONDITIONS Direction of rotation : CW/ CCW facing driving end/Both
Supply system : 415 V, 3-Phase, 50 Hz Preferred method of cooling: -
(NOTE 1)
Environmental conditions : Tropical, corrosive, humid and salt laden offshore saliferous - Frame surface : Yes
(NOTE 1)
environment. - Air to air : Yes
(NOTE 1)
Location : Offshore Sarawak, Malaysia - Air to water : Yes / No
o
Ambient air temperature, min. : 20 C Type of mounting: -
o (NOTE 1)
Ambient air temperature, max. : 35 C - Horizontal : foot/ flange
(NOTE 1)
Cooling water temp. min. : N/A oC - Vertical : foot/ flange
(NOTE 1)
Cooling water temp. max. : N/A oC Number of starts per year : Nominal/heavy/extra heavy
(NOTE 1)
Relative humidity, max. : 100 % Locked rotor current : IEC 60034
Relative humidity, min. : 13 % Noise limitations at full load : IEC 60034
Tropical treatment required : Yes (Max. sound pressure level)
Direct sunlight : Yes Motor Insulation Class : Class F
Design Temperature Rise at rated power : Class B

CONSTRUCTION REQUIREMENT
Feeder cable Type : (NOTE 4)
Size : (NOTE 1)
EX PROTECTION Cable O.D. : (NOTE 1)
Area classification : Zone 2 Type of cable gland : Dual certified Ex'd' and Ex'e', nickel
Temperature classification : T3 plated brass
Gas group classification : IIA Anti-condensation Heaters (NOTE 2 and 3) : (NOTE 2)
Ex Protection : Ex 'n' Anti-condensation Heater supply voltage : 240V
Note : Permitted protection types Anti-condensation Heater Cable Type : (NOTE 1)
Zone 1 Zone 2 Size : (NOTE 1)
Ex'd' (IEC 60079-1) Yes Yes Cable O.D. : (NOTE 1)
Ex'p' (IEC 60079-2) Yes Yes Aluminium frame allowed : No
Ex'e' (IEC 60079-7) LV only Yes *** (<22kW, non-hazardous, non-essential)
Ex'n' (IEC 60079-15) No Yes *** CONDITION MONITORING
(NOTE 1)
*** Not for hydrocarbon centrifugal or screw compressors Bearing temperature monitoring : No
(NOTE 1)
Vibration monitoring : No
(NOTE 1)
DRIVEN EQUIPMENT Sleeve bearings - Proximity probes : No
(NOTE 1)
Type : Cooling Pump Motor Rolling element brgs. - SPM : No
Motor part of Variable Frequency Drive : Yes
(NOTE 1) (NOTE 1)
Moment of inertia : kgm2 Winding discharge monitoring : No
(NOTE 1)
Torque/ speed curve :
(NOTE 1)
Type of coupling : INSPECTION AND TESTING
Requisition Number : MY-SK309-66-ME-SP-0001 Production tests to be witnessed : No
Tests to be witnessed: -
ACCESSORIES (TO BE FILLED BY THE VENDOR WITH THE QUOTATION) - Rotor balance : No
- Sample coil (HV) : No
Nameplate (Duplex Stainless Steel) - Water coolers (HV) : No
Anti-condensation Heaters (NOTE 2) (240 V, 1-Phase, 50Hz) Performance Test (NOTE 13) : Yes
Separate Anti-condensation Heaters Terminal Box (NOTE 2) Routine test (HV only) : No
Stator Thermistor (PTC Type) Qty: Special tests : No
Thermistor Relay (240 V, 1-Phase, 50Hz)
RTD Selector Switch - Indicator and Alarm Contact ADDITIONAL INFORMATION
Bearing RTD (Type PT 100) Qty: / bearing Starting Current vs Speed Curve (NOTE1)
Stator RTD (Type PT 100) Qty: / phase Torque vs Speed Curve (NOTE 1)
Separate RTD/Thermistor/Space Heater Terminal Box Power,kW vs Speed Curve (NOTE 1)
Differential CT
Earth Fault Protection
Earth Fault Protection CT
Bearing Oil Temperature Indicators

* Refer Sheet No. 2 for Notes


PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES FOR
MURPHY'S OPERATIONS

WORK ORDER TITLE : PROVISION OF ENGINEERING WORKS FOR GOP-B


BOOSTER COMPRESSOR (FEED)

WORK ORDER NUMBER : WO 25B

F0 12.06.2020
ABS
MMCOG PROJECT NUMBER : MSO-A-0088 Approved for Bid NAA NM ABS
FA 11.06.2020 Issued for Review NAA NM ABS
PREPARED APPROVED REVIEWED
CONTRACT NUMBER : MURPHY/S18039 REV DATE REVISION DESCRIPTION CHECKED MMC
MMC MMC PTTEP
Sheet No 2 cont'd on sheet No. 3
Eng. By : MMC Oil & Gas Engineering Sdn. Bhd. (125442-W) Datasheet No. MY-SK309-66-EL-DS-0003

Client : PTTEP HK Offshore Limited Specification No. MY-SK309-66-ME-SP-0001


PTTEP Sarawak Oil Limited
PTTEP Sabah Oil Limited
ELECTRICAL DATASHEET Equipment No : P-XXXX
GAS BOOSTER COMPRESSOR PACKAGE - COOLING PUMP MOTOR Equipment Name : COOLING PUMP MOTOR FOR GAS BOOSTER COMPRESSOR PACKAGE
Quantity : TWO (2) x 100%
MISCELLANEOUS REQUIREMENT
Insulation class : F Enclosure : IP 56 (including Terminal Box)
Operating temperature rise : B Shaft : Solid
Winding treatment: - Motor type : Squirrel cage
- Vacuum pressure impregnated : Yes Fan : Anti-static, bi-directional
(NOTE 1)
- Tropicalised : Yes DE axial bearing : Sleeve / Roller / Ball
(NOTE 1) (NOTE 1)
Winding connection : Delta NDE axial bearing : Sleeve / Roller / Ball
(NOTE 1)
Duty cycle : Continuous Mounting Type : Horizontal/Vertical
(NOTE 1)
Starting method : Variable Frequency Drive Bearing lubrication : Grease
Grounding stud: -
- On external motor frame : Yes
- Inside main terminal box : Yes
Finish : (NOTE 14)
Frame material : Cast iron
Terminal boxes : Rotatable in 90o increment
(Rotation shall suit for bottom / side
cable entry only)
SPECIAL REQUIREMENT
Non-standard terminal box position : No
Special tests : Yes
At tender: -
- Mass of motor (kg) : Yes
- Moment of inertia 'j' (kg m2) : Yes
- Lubrication requirements in case of force-lubricated bearings : Yes
- Layout of terminal box : Yes
On receipt of order: -
- Calculated critical speed (s) (1/min) : Yes
- Transient air-gap torque plots : with two and three-phase short-circuit at the motor terminals, and with their respective frequencies over : Yes
a 200 ms time period (Nm)
- Stalling times, hot and cold (s) : Yes
- Running-up times : Yes
- Dynamic model of motor to enable accurate flywheel sizing for reciprocating load and recommended flywheel size : Yes
- Rotor residual voltage time-constants and transient air-gap torques on reconnection after power interruption : Yes
- Heating/cooling time constants for thermal replica protection : Yes
- Maximum tolerable axial force : Yes
- Thermal endurance graphs showing insulation life versus temperature in the range including classes B and F; such results shall be : Yes
based on actual coils employing the Manufacturer's insulation system, tested to IEEE 117 or IEEE 275 as appropriate.
At testing: -
- Severity of multiples of the supply frequency present in the vibration spectrum : Yes
- Total all-in cost calculation require : Yes
- Data to permit TAC calculation: -
Capc Kot Ecost MDC
- Electromagnetic compatibility restrictions : Yes
ADDITIONAL INFORMATION
Notes: -
1) Data to be reviewed/confirmed by VENDOR.
2) Motors 5.5 KW and above shall be equipped with anti-condensation space heaters. Where motors are fitted with anti-condensation heaters, a heater safety switch shall be installed
adjacent to the motor's RCU. Anti-condensation heaters for on-skid located control panels shall be automatically controlled via an integrated thermostat.
An (two-pole) isolating switch shall be provided.
3) N/A - Not Applicable
4) Cable shall be sized based on the actual rating of the selected motor and taking into account the voltage drop of cable due to length,motor starting,derating factor etc. All power and control
cables shall be stranded copper conductor, Cross Linked Polyethylene (XLPE) insulated with Steel Wire Braided (SWB) (for cable 10mm2 and below) or Steel Wire Armored (SWA)
(for cable size 16mm2 and above), inner sheated (bedding) and outer sheath shall be Low Smoke Zero Halogen type complying with IEC 60754-2.
5) Codes, standards and regulations refered to shall be of the latest edition.
6) Manufacturer's standard for increased protection against corrosion under the site conditions above. COMPANY shall be consulted if the manufacturer's one coat of primer and two
coats of oil resistant finishing paint standards are less stringent than surface preparation by blast cleaning.
7) Parts, including cables, which are in contact with the sea water, shall be chemically and thermally resistant to chemical and sea water over the lifetime of the motor
8) Rain canopy shall be provided for motor with vertical shaft.
9) Manufacturer's standard may be accepted, subject to submittal and approval by COMPANY
10) Motor shall be suitable for the end of the pump curve operation
11) For LV machines, the manufacturer's routine/production test shall be performed on every machine.
12) Vendor to provide type test certificate for motor of the same model and rating.
13) Performance test shall be as specified in IEC 60034
14) VENDOR shall comply to COMPANY General Design Requirements - Topsides Protective Coatings ( Doc. No.: MOM-SWK-10-QU-SP-0001-00) as required.
15) Motor rating 30kW and above and all rating submersible motors shall have earth fault protection.

References: -
1) Electrical Design Basis and Philosophy (Doc. No.: MY-SK309-66-EL-DG-0001-00)
2) Specification for Electrical Equipment for Packaged Unit (Doc. No.: MOM-SK311-91-EL-SP-0008)

Sheet No 3 cont'd on sheet No. 4


Eng. By : MMC Oil & Gas Engineering Sdn. Bhd. (125442-W) Datasheet No. MY-SK309-66-EL-DS-0003

Client : PTTEP HK Offshore Limited Specification No. MY-SK309-66-ME-SP-0001


PTTEP Sarawak Oil Limited
PTTEP Sabah Oil Limited
ELECTRICAL DATASHEET Equipment No : P-XXXX
GAS BOOSTER COMPRESSOR PACKAGE - COOLING PUMP MOTOR Equipment Name : COOLING PUMP MOTOR FOR GAS BOOSTER COMPRESSOR PACKAGE
Quantity : TWO (2) x 100%
INFORMATION TO BE SUBMITTED BY VENDOR
GENERAL PERFORMANCE DATA CONSTRUCTION DATA
Manufacturer : Allowable number of starts per year : …………………… Bearing Location : Endshield/pedestal
Compliance with IEC60034 : Yes/ No Full load current (FLC) : …………………………A Bearing (s) DE make
:
and requisition i) Power factor 100%/ 75% load : ………./ ..…… type
Additional information required ii) : Efficiency 100%/ 75% load : ...…../ ...…. % clearance
Main Parts Country of origin / town Total / Partly Locked rotor current at Un/ 0.8 Un : ………./ …....…. % FLC Bearing (s) NDE: make
Stator Locked rotor torque at Un/ 0.8 Un : ………./ ……….. % FLT type
Rotor Pull up torque at Un/ 0.8 Un : …………./ ………… % FLT clearance
Local Service Name : Breakdown torque at Un/ 0.8 : Un : ……… / …….. % FLT Bearing lifetime : ……………… Hrs
Organisation Country / Town : Motor Impedance %X": = ……………….. Lubricant : Oil/ grease
%X' = ……………….. Shell type :
BASIC DATA %X2 = ……………….. Lub. System :
Type and frame number : X/R = ……………….. Sealing/ regreasable/ oilring/ disc/ forced
Rated voltage and frequency : VHz Running up time at Un/ 0.8 Un : …….. / ……………. S Maximum relubrication interval : ………. Hrs
- Rating : Allowable running up time at Un / 0.8 Un ……/ ………… S Min/ Max oil flow :
- Full load speed : EEX-e motor to time : ……………………………………..S Metallic cage bearing : yes/ ……………..
Direction of rotation facing driving end : Vibration at no-load ………………………………. Mm/s RMS Axial float rotor : + ……….. mm/- ………….. mm
CW/ CCW/ both Critical speed (s) : …………………………….. r/min Rotor balance grade : G1/ ………………
Degree of protection of motor and auxiliaries : Rotor inertia (J) : ……………………………. Kgm2 Max axial force : ……………… N
IP 56/ ………. Max. sound pressure level at full load : dB (A) Bearing insulation provided : yes/ no
Degree of protection of terminal boxes and bearings : Are noise correction measures used : yes/ no Bearing bore diameter DE/ NDE : …………. mm
IP 56/ ………. (if yes, please state below) Stator frame : (Cast iron/ steel)
Suitable for use in classified area : Max. transient air gap torque when : Min. flywheel size (constant-torque load) : ………….. kgm2
Zone …………………… - two phase short circuit at motor terminals : ………. kNm Flywheel alternative and volt-dip duration : ………… kgm2, S
Temperature classification : T ……………………… - three phase short circuit at motor terminals : ………. kNm Magnetic slot wedges used : yes/ no
Gas group (if applicable) : ……………………….. - restart with full opposite residual voltage possible : Magnetic slot wedges ………………. life years
Certification of Conformity available : Yes/ ………………. Yes/ ………. kNm
Type of protection of motor and auxiliaries : - 120 degree reconnection : ………. kNm HV cable connection : Bushing/ Tail/ ……………….
Stall time hot/ cold : …………….. / ……………………..s Water cooler : Single tube/ …………………..
Type of protection of terminal boxes : Heating/ cooling constants : ………………………………….. Surplus water tubes : 20/ ………………….. %
Method of cooling : IC 4AIAI / ………………………
Method of mounting : IM 1001 / ………………………. Total net weight : ………………………… kg
Anti-Condensation heater rating ……………………… W
Proposed coupling fit : Keyed/ Hydraulic/ Integral STARTING CHARACTERISTICS INSPECTION AND TESTING
Starting Method : …………………… Type Test results submitted : -
NOTES Starting Performance (IEC60034-12) : …………………… - LV performance test yes/ no
i) Describe deviations Starting Current at Un/ 0.8 Un : ………./ ……….. pu - HV sample coil test yes/ no
Starting Power Factor at Un/ 0.8 Un : ………./ ……….. pu - HV winding temp. rise yes/ no
Locked rotor torque at Un/ 0.8 Un : ………./ ……….. pu - HV locked rotor current/ torque
yes/ no
Max Starting Time at Un/ 0.8 Un : ………./ ……….. s - Confirm testing to IEC yes/ no
ii) Describe additional information required Maximum Allowable Stall Time : ………./ ……….. s (Hot / Cold) (list deviations below)
Thermal Time Constants : ………./ ……….. s (Heating / Cooling)
Max. no. of Starts Per Hours : ……………………
Max. no. of Starts Per Year : ……………………

ADDITIONAL INFORMATION

Sheet No 4 cont'd on sheet No. 5


Eng. By : MMC Oil & Gas Engineering Sdn. Bhd. (125442-W) Datasheet No. MY-SK309-66-EL-DS-0003

Client : PTTEP HK Offshore Limited Specification No. MY-SK309-66-ME-SP-0001


PTTEP Sarawak Oil Limited
PTTEP Sabah Oil Limited
ELECTRICAL DATASHEET Equipment No : P-XXXX
GAS BOOSTER COMPRESSOR PACKAGE - COOLING PUMP MOTOR Equipment Name : COOLING PUMP MOTOR FOR GAS BOOSTER COMPRESSOR PACKAGE
Quantity : TWO (2) x 100%
SPECIFIC REQUIREMENT
GENERAL
- When motors are furnished with the driven equipment as a package, the torque characteristics and speed shall be the responsibility of the driven equipment VENDOR. Motor design shall be based on IEC 60034.
- The cable entry size for the terminal boxes shall be suitable for PURCHASER's cable termination. The cable entry size shall be approved by PURCHASER.
- Motors and all individual items forming part of motors shall have an expected service life of 15 years. This includes heaters, wirings, terminals etc. but with the exception of the rolling element bearings.
- Motor screens or louvres shall be corrosion resistant.
- Motors shall be provided with lifting eyes or other types of facilities to lift the motors.
- In the event a Variable Speed Cooling Pump Motor is required, the starting of the motor shall be by VFD to control the speed of the pump motor.

WINDINGS
- All windings shall be adequately supported, braced and wedged to limit coil and end winding vibration and subsequent cracking of the winding insulation.
- Bracing, blocking and wedging shall be positively secured to allow for the vibration and forces experienced during the expected 15 year service life of the machine.
- The windings especially the end windings shall be adequately braced to prevent movement and cracking of the insulation at the slot exists during all conditions of service.
- Windings shall be able to withstand the dynamic forces which result from frequent starting and from re-starting against opposite residual voltage.

BEARINGS
- Bearings shall have a rated L10 lifetime in excess of 40,000 hours under the worst case operating conditions. The lifetime shall be calculated in accordance with ISO R 281-1.

TERMINAL BOXES AND MOTOR TERMINALS


- The main terminal box shall permit easy mounting and removal of the cable without breaking or stressing the cable.
- Terminals and cable termination boxes shall provide sufficient space for segregating the cores and maintaining the minimum insulation clearances and creepage distances.
- Cable terminals, terminal leads, and associated fittings for motors controlled by conventional circuit breakers shall be able to withstand a maximum through fault level.
- The main cable terminals inside the cable box shall have the following characteristics: -
a) be non-loosening to prevent slackening of connection due to vibration.
b) guaranteed sufficient contact pressure without damaging the cable conductor.
c) guaranteed good contact, independent of temperature changes and other conditions mentioned in the specification.
- An earthing clamp or bolt of adequate dimensions shall be provided inside the terminal box for connection of the cable earthing.
- An earth stud terminal with nuts and washers and diameter not less than that of a line terminal shall be provided on the exterior of the motorframe for the connection of an earthing cable.

ARRANGEMENT
- The following motor terminal and space heater terminal boxes arrangement shall be provided :

b a NDE b a: Motor terminal box


b: Space heater terminal box

VENDOR DATA REQUIREMENTS


- The VENDOR shall supply as a minimum the following data for the purpose of evaluation, approval and records by CONTRACTOR :-
a) All physical drawings showing all dimensions, location of terminals boxes and size, connection diagrams, methods of terminations, couplings, keyways etc.
b) A complete set of installation, operating and maintenance data.
c) A list of recommended spares {separately priced).

MOTOR NAMEPLATE
Each motor shall be equipped with a stainless steel nameplate permanently attached to the motor. Information shall be impressed onto the nameplate and shall include the following :-
a) Manufacturer's name. i) Rated speed q) Motor tagging number
b) Manufacturer's serial number and year of manufacture j) Class of insulation and temperature rise
c) PURCHASER purchase order number k) Power factor at full load
d) Degree of protection of motor and terminal boxes l) Efficiency at full load
e) Rated ouput m) Locked rotor current at rated voltage and frequency
f) Rated voltage and winding connection n) Locked rotor torque at rated voltage and frequency
g) Rated current o) Allowable running-up time (ART) at rated voltage and 80% rated voltage.
h) Rated frequency and number of phase p) Bearing model, number/part number

Sheet No 5 cont'd on sheet No. -


Eng. By : MMC Oil & Gas Engineering Sdn. Bhd. (125442-W) Datasheet No. MY-SK309-66-EL-DS-0003

Client : PTTEP HK Offshore Limited Specification No. MY-SK309-66-ME-SP-0001


PTTEP Sarawak Oil Limited
PTTEP Sabah Oil Limited
DATASHEET Equipment No : A-2410A/B
Equipment Name : BOOSTER COMPRESSOR PACKAGE
BOOSTER COMPRESSOR PACKAGE
Quantity : VTA

Item No. INSTRUMENT Sheet No. Rev No. Remarks

MY-SK309-66-IC-DS-
1 ACTUATED BALL VALVE F1 BOOSTER COMPRESSOR PACKAGE
0010-02

MY-SK309-66-IC-DS-
2 CONTROL VALVE F1 BOOSTER COMPRESSOR PACKAGE
0010-06

MY-SK309-66-IC-DS-
3 PRESSURE GAUGE F1 BOOSTER COMPRESSOR PACKAGE
0010-09

MY-SK309-66-IC-DS-
4 PRESSURE TRASMITTER F1 BOOSTER COMPRESSOR PACKAGE
0010-11

MY-SK309-66-IC-DS-
5 RELIEF VALVE F1 BOOSTER COMPRESSOR PACKAGE
0010-13

MY-SK309-66-IC-DS-
6 TEMPERATURE TRANSMITTER F1 BOOSTER COMPRESSOR PACKAGE
0010-14

PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES


FOR MURPHY'S OPERATIONS

WORK ORDER TITLE :


PROVISION OF ENGINEERING WORKS FOR GOPB
BOOSTER COMPRESSOR (FEED)

WORK ORDER NUMBER :


WO-025B

MMCOG PROJECT NUMBER : MSO-A-0088

F1 19-06-2020 Re-Approved For Bid NFT MJ


ABS
ABS

CONTRACT NO. : MURPHY/S18039 F0 - Not Used - - -


FA 15-06-2020 Issued For Review NFT MJ ABS
PREPARED CHECKED APPROVED APPROVED
REV DATE REVISION DESCRIPTION
MMC MMC MMC PTTEP
MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 1 cont'd on sheet No. 2
Eng. By :
Datasheet No.
MY-SK309-66-IC-DS-0010
Client : PTTEP
HK Offshore Limited (0995613W )
PTTEP Sarawak Oil Limited (993918-P) Specification No.
MY-SK309-66-ME-SP-0001
PTTEP Sabah Oil Limited (993919-M)
DATASHEET Equipment No : A-2410A/B
Equipment Name : ACTUATED BALL VALVE (TYPICAL)
ACTUATED BALL VALVE
Quantity : VTA

1 GENERAL 53 ACTUATOR
2 TAG NUMBER VTA 54 TYPE PNEUMATIC, SPRING RETURN
3 FLUID HC GAS 55 MFR & MODEL VTA
4 SERVICE 56 SIZE VTA
BOOSTER COMPRESSOR
5 57 FIRE-SAFE YES
6 P & ID No. MY-SK309-65-PR-DW-0002-01 58 SPRING ACTION OPEN/CLOSE CLOSE
7 LINE No. VTA 59 AIR FAILURE POSITION CLOSE
8 LINE SIZE PIPING CLASS VTA VTA 60 MAX ALLOWABLE PRESSURE (Barg) 13
9 PROCESS CONDITIONS 61 MIN REQUIRED PRESSURE (Barg) 5.5
10 DESIGN PRESSURE (Barg) VTA 62 AVL. AIR PR.(Min/Norm/Max) (Barg) 5.5 / 7 / 10 / 13
11 DESIGN TEMP. (deg C) VTA 63 BREAK TORQUE RUN TORQUE VTA VTA
12 DELATA P (ΔP) (Bar) VTA 64 TIME OPEN CLOSE (SEC) VTA ≤6 (NOTE 24)
13 65 BENCH RANGE VTA
14 APPLICABLE CODES AND SPECIFICATIONS 66 ACTUATOR ORIENTATION PARALLEL TO FLOW
15 DESIGN CODE ( VALVE ) API 6D 67 HANDWHEEL TYPE NO -
16 FIRE-SAFE (VALVE) API-6FA or API-607 6th Edition 68 ADJUSTABLE STROKING TIME YES
17 SEAT LEAKAGE CLASS AS PER PIPING VALVE CODE 69 AIR CONSUMPTION VTA
18 VALVE 70 POSITION INDICATION (MECH) YES
19 TYPE VALVE CODE TRUNNION VTA 71 ACTUATOR TEST PRESSURE VTA
20 SIZE RATING DN ASME 72 ACCUMULATOR (VOLUME BOTTLE) NO
21 FLANGE FACE FINISH VTA 73 LIMIT SWITCHES
22 74 TAG No. OPEN / TAG NO. CLOSE VTA
23 BORE TYPE REDUCED 75 TYPE (PROXIMITY, FIELD SWITCH) 2 Nos. SPDT, SS 316
24 MATERIAL BODY (**) VTA 76 CONTACTS/RATING 0.5A, 24 VDC
25 BALL (**) VTA 77 ACTUATION POINTS OPEN / CLOSE
26 STEM (**) VTA 78 ENCLOSURE IP 66 & Eex"d"
27 SEAT RING (**) VTA 79 CABLE ENTRY SIZE/QTY M20 / 2 Nos.
28 SEAT INSERT (**) VTA 80 MFR & MODEL WESTLOCK, MAGNUM OR EQUAL
29 STEM SEAL (**) VTA 81 FILTER REGULATOR
30 PACKING (**) VTA 82 MFR & MODEL VTA
31 BOLT/NUT (**) VTA 83 FILTER / REGULATOR YES / YES
32 MFR & MODEL VTA 84 LUBRICATOR NO
33 VALVE COLOUR (**) 85 SET PRESSURE VTA
34 86 OUTPUT GAUGE YES ( WITH 316 CASING )
35 VOLUME BOTTLE 87 SOLENOID VALVE
36 CAPACITY - 88 TAG No. VTA
37 SAFETY VALVE - 89 TYPE 3 WAY, NORMALLY ENERGISED
38 NO. OF OPERATIONS - 90 QTY 1 (ONE)
39 PRESSURE GAUGE - 91 MANUAL / AUTO RESET AUTO RESET
40 MFR & MODEL - 92 SIZE VTA
41 93 POWER SUPPLY 24 VDC ±10%
42 ADDITIONAL INFORMATION 94 POWER CONSUMPTION 2 WATT OR LESS
43 PNEUMATIC CONN. SIZE 1/2” O.D. x 0.035” W.T 95 NO. OF COILS 1 No.
44 TUBES FITTINGS 316L SS 316 SS 96 COIL TYPE CLASS H
45 AREA CLASSIFICATION IEC Zone 1, GAS Gr. IIA, TEMP T3 97 BODY MATERIAL SS 316
46 98 CABLE ENTRY SIZE/QTY M20 / 1 No.
47 SPECIAL REQUIREMENT 99 ENCLOSURE IP-66 & EEx'd'
48 SIL REQUIREMENT SIL 1 (VTA) 100 MFR & MODEL BIFOLD OR EQUAL
49 PARTIAL STROKE YES 101
50 ACTUATOR COLOUR 102
51 103
52 104

VTA - VENDOR TO ADVISE

PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES


FOR MURPHY'S OPERATIONS

WORK ORDER TITLE : PROVISION OF ENGINEERING WORKS FOR GOPB


BOOSTER COMPRESSOR (FEED)

WORK ORDER NUMBER : WO-025B

MMCOG PROJECT NUMBER : MSO-A-0088

F1 19-06-2020 Re-Approved For Bid NFT MJ ABS


ABS
CONTRACT NO. : MURPHY/S18039 F0 - Not Used - - -
FA 15-06-2020 Issued For Review NFT MJ ABS
PREPARED CHECKED APPROVED APPROVED
REV DATE REVISION DESCRIPTION
MMC MMC MMC PTTEP

Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 2 cont'd on sheet No. 3

Datasheet No.
MY-SK309-66-IC-DS-0010
Client : PTTEP HK Offshore Limited (0995613W )
PTTEP Sarawak Oil Limited (993918-P) Specification No.
MY-SK309-66-ME-SP-0001
PTTEP Sabah Oil Limited (993919-M)
DATASHEET Equipment No : A-2410A/B
Equipment Name : ACTUATED BALL VALVE (TYPICAL)
ACTUATED BALL VALVE
Quantity : VTA

GENERAL NOTES

1. EACH INSTRUMENT SHALL HAVE A 30 MM X 75 MM OF 20 GAUGE THICKNESS 316SS TAG PLATE WITH TAG NUMBER AND SERVICE ENGRAVED
OR EMBOSSED IN 6 MM HIGH X 0.3 MM DEEP BOLD CHARACTERS. ONE TAG PLATE PERMANENTLY ATTACHED TO INSTRUMENT BY SCREW /
RIVET.SECOND ADDITIONALTAG PLATE SHALL ALSO BE SUPPLIED AND ATTACHED TO THE INSTRUMENT WITH SS WIRE.

2. VENDOR SHALL SUPPLY PNEUMATIC ACTUATOR COMPLETE WITH CONTROL CIRCUIT ACCESSORIES AS SHOWN IN THE SCHEMATIC DIAGRAM.
ALL ITEMS SHALL BE FULLY TUBED, ASSEMBLED AND MOUNTED ONTO THE VALVE. SS PLATE SHALL BE ATTACHED TO THE ACTUATOR AND ALL ACCESSORIES
SHALL BE MOUNTED ON THE PLATE. ALL ACCESSORIES SHALL BE EASILY ACCESSIBLE FOR MAINTENANCE.

3. ACTUATOR CONTROL CIRCUIT SHALL BE DESIGNED TO PROVIDE AN ADJUSTABLE VALVE STROKING TIME. AS GENERAL MAXIMUM OPENING/CLOSING TIME SHALL
BE 1 SECOND WITH A MAXIMUM OF 45 SECONDS.

4. ACTUATORS ARE TO BE SIZED BASED ON THE TORQUE REQUIREMENT AS FOLLOWS :


i) FOR ALL SDVs AND BLOWDOWN, THE ACTUATOR TORQUE SHALL BE A MINIMUM OF 1.5 TIMES THE TORQUE REQUIRED TO CLOSE THE VALVE FROM THE
OPEN/CLOSE POSITION WITH THE VALVE BORE AT THE MAXIMUM OPERATING PRESSURE AND WITH THE VALVE CAVITY AT ATMOSPHERIC PRESSURE.

5. ALL MOUNTING BRACKETS, BOLTS AND NUTS, ETC TO BE USED FOR INSTRUMENTS SHALL BE 316 SS MATERIAL.

6. ALL MATERIALS SUPPLIED FOR ASSEMBLY SHALL BE SUITABLE FOR SALT-LADEN OFFSHORE ENVIRONMENT. THE CENTRE BODY SECTION SHALL BE FULLY ENCLOSED.

7. TUBING SHALL BE 316L SS. TUBING SHALL BE COLD FINISHED, SEAMLESS, BRIGHT ANNEALED WITH A MINIMUM MOLYBDENUM CONTENT OF 3.5% AND MAXIMUM
HARDNESS OF RB-90. THE SELECTION AND TUBING SHALL BE BETTER OR EQUAL AS SPECIFICATION. TUBE FITTINGS SHALL BE 316 STAINLESS STEEL.

8. VALVE PROXIMITY SWITCHES SHALL BE SET TO ACTIVATE AT THE "FULLY OPENED" AND "FULLY CLOSED" VALVE POSITION. LIMIT SWITCHES SHALL BE PROVIDED
WITH FULLY ENCLOSED HOUSING FOR THE CONNECTION BETWEEN THE ACTUATOR AND SWITCH ENCLOSURE. PURCHASER SHALL CONNECT BOTH (OPEN & CLOSE)
PROXIMITY SWITCHES USING 2-PR CABLE. IN CASE SWITCH ENCLOSURE IS PROVIDED WITH TWO (2) CABLE ENTRIES, ONE CABLE ENTRY SHALL BE PLUGGED BY
VENDOR BY USING CERTIFIED EXPLOSION PROOF PLUG.

9. SOLENOID VALVES SHALL BE OF 316 SS MATERIAL WITH CLASS H COIL INSULATION SUITABLE FOR CONTINUOUS ENERGISED DUTY. SOLENOID SHALL BE INDIRECT
TYPE WITH LOW POWERED CONSUMPTION. THE CONSUMPTION SHALL NOT EXCEED 2 WATTS.

10. SOLENOID VALVES SHALL BE CERTIFIED EXPLOSION PROOF (EExd), SUITABLE FOR THE SPECIFIED HAZARDOUS AREA.THE MINIMUM TEMPERATURE CLASS SHALL BE T3.
THE DEGREE OF INGRESS PROTECTION PROVIDED BY THE ENCLOSURE SHALL BE IP 65 OF IEC 60529 AS A MINIMUM AND CERTIFIED SUITABILY BY COMPETENT
AUTHORITY e.g. CENELEC/ATEX

11. THE ACTUATOR AND ALL RELATED ACCESSORIES INCLUDING SOLENOID VALVES, PROXIMITY SWITCHES ETC. SHALL BE SUITABLE FOR OPERATION IN MARINE, HUMID,
AND SALIFEROUS ATMOSPHERE.

12. INSTRUMENT AIR SUPPLY FOR ACTUATOR SHALL BE AS THE FOLLOWING SUPPLY PRESSURE :
- MINIMUM 5.5 Barg
- NORMAL 7 Barg
- MAXIMUM 13 Barg

13. ALL THE ACCESSORIES FOR REMOTE-MOUNTED SDV SUCH AS FILTER, RESTRICTORS, ETC. SHALL BE BOLTED ON TO A STAINLESS STEEL MOUNTING PLATE,
WHICH SHALL BE FIXED TOGETHER WITH THE ACTUATOR.

PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES


FOR MURPHY'S OPERATIONS

WORK ORDER TITLE :


PROVISION OF ENGINEERING WORKS FOR GOPB
BOOSTER COMPRESSOR (FEED)

WORK ORDER NUMBER :


WO-025B

MMCOG PROJECT NUMBER : MSO-A-0088

F1 19-06-2020 Re-Approved For Bid NFT MJ


ABS
ABS
CONTRACT NO. : MURPHY/S18039 F0 - Not Used - - -
FA 15-06-2020 Issued For Review NFT MJ ABS
PREPARED CHECKED APPROVED APPROVED
REV DATE REVISION DESCRIPTION
MMC MMC MMC PTTEP

Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 3 cont'd on sheet No. 4

Datasheet No.
: PTTEP
MY-SK309-66-IC-DS-0010
Client HK Offshore Limited (0995613W )
PTTEP Sarawak Oil Limited (993918-P) Specification No.
MY-SK309-66-ME-SP-0001
PTTEP Sabah Oil Limited (993919-M)
DATASHEET Equipment No : A-2410A/B
Equipment Name : ACTUATED BALL VALVE (TYPICAL)
ACTUATED BALL VALVE
Quantity : VTA

GENERAL NOTES

14. THE OPEN AND CLOSE PROXIMITY SWITCHES SHALL BE PROVIDED WITH FULLY ENCLOSED HOUSING FOR THE MECHANICAL CONNECTION BETWEEN
THE ACTUATOR AND THE PROXIMITY SWITCH ENCLOSURE.

15. PAINTING SHALL BE IN ACCORDANCE WITH SPECIFICATIONS FOR PAINTING AND COATING (DOC NO : MOM-SWK-10-QU-SP-0001-00).

16. ACTUATOR AND VALVES WITH WEIGHT ABOVE 25 KG SHALL BE FITTED WITH LIFTING LUG.

17. SOFT SEAT AND NON METALLIC MATERIALS SHALL COMPLY WITH VALVE BODY DESIGN PRESSURE AND TEMPERATURE.

18. SOLENOID VALVE SHALL BE PROVIDED WITH TERMINAL BLOCKS. FLYING LEADS DESIGN SHALL NOT BE ACCEPTABLE.

19. SOLENOID VALVE TO BE SUPPLIED WITH BUILT-IN SURGE SUPPRESSION DIODE. SOLENOID VALVE SHALL BE 316SS MATERIAL WITH CLASS H COIL INSULATION SUITABLE FOR
CONTINUOUS ENERGISED DUTY.

20. ALL MATERIALS SHALL BE IDENTIFIABLE AGAINST THEIR CERTIFICATIONS AND SHALL AS A MINIMUM COMPLY WITH THE REQUIREMENTS OF EN 10204 - TYPE 3.2 (HOLD).

21. VALVE DATASHEET SHALL BE FINALIZED DURING DETAILED DESIGN.

22. VALVE SHALL BE MEET AND CERTIFIED WITH MINIMUM SAFETY INTEGRITY LEVEL 1 (SIL-1) - TO BE CONFIRM BY VENDOR.

PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES


FOR MURPHY'S OPERATIONS

WORK ORDER TITLE :


PROVISION OF ENGINEERING WORKS FOR GOPB
BOOSTER COMPRESSOR (FEED)

WORK ORDER NUMBER :


WO-025B

MMCOG PROJECT NUMBER : MSO-A-0088 ABS


F1 19-06-2020 Re-Approved For Bid NFT MJ ABS
CONTRACT NO. : MURPHY/S18039 F0 - Not Used - - -
FA 15-06-2020 Issued For Review NFT MJ ABS
PREPARED CHECKED APPROVED APPROVED
REV DATE REVISION DESCRIPTION
MMC MMC MMC PTTEP
Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 4 cont'd on sheet No. 5

Datasheet No.
MY-SK309-66-IC-DS-0010
Client : PTTEP
HK Offshore
Sabah Limited
Oil Limited (0995613W )
(993919-M)
PTTEP Sarawak Oil Limited (993918-P) Specification No.
MY-SK309-66-ME-SP-0001
DATASHEET Equipment No : A-2410A/B
Equipment Name : ACTUATED BALL VALVE (TYPICAL)
ACTUATED BALL VALVE
Quantity : VTA

SHUTDOWN VALVE HOOK-UP SCHEMATIC SK/IN/0001

24 VDC SIGNAL UCP UCP


FROM UCP GBO GBC

YYYY YYYY

SV
YYY
H
A B

INSTRUMENT
AIR SUPPLY
GSO GSC
YYYY YYYY
VENT

OPEN CLOSE

MALE G C
CONNECTORS
D
AIR TO OPEN SPRING TO CLOSE

MOUNTING PLATE 316SS 5mm THK TO


BE MOUNTED AT ACTUATOR BY
VALVE'S VENDOR

F SHUTDWON VALVE
(FAIL CLOSE)

VENDOR'S SCOPE OF SUPPLY

INSTRUMENT BILL OF MATERIAL (NOTE 1)


ITEM
DESCRIPTION (NOTE 2) MATERIAL SIZE QUANTITY
No.
A INSTRUMENT AIR FILTER REGULATOR C/W PRESSURE GAUGE AISI 316 1/4" NPTF 1
B ADJUSTABLE FLOW CONTROL VALVE AISI 316 BY VENDOR 1
C VENT PROTECTOR AISI 316 1/4" OD 1
D TUBING SEAMLESS FULLY ANNEALED TO ASTM A269 WITH MO CONTENT > 2.5%AISI 316L 1/2" OD x 0.035" W.T. BY VENDOR
E QUICK EXHAUST VALVE C/W BLEED CONTROL VALVE AISI 316 BY VENDOR 1
F DUST EXCLUDER AISI 316 BY VENDOR 1
G BALL VALVE, SCREWED AISI 316 1/2" NPTF 1
H SINGLE COIL SOLENOID VALVE, SPRING RETURN 24 VDC, 3 WAY NC, AISI 316 3/8" NPTF 1
ENERGISE TO OPEN M20 ELEC. CONNECTION Ex'd' WITH AUTO RESET

1. THE ABOVE BILL OF MATERIAL IS FOR ONE INSTALLATION. VENDOR SHALL SUPPLY ALL NECESSARY ADAPTOR/FITTING TO COMPLETE THE INSTALLATION AS REQUIRED.
2. SIZE INDICATED IN MATERIAL DESCRIPTION IS MINIMUM. VENDOR SHALL VERIFY AND PROVIDE SIZE TO MEET TIMING REQUIREMENTS.
3. REFER GENERAL NOTES.

PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES


FOR MURPHY'S OPERATIONS

WORK ORDER TITLE :


PROVISION OF ENGINEERING WORKS FOR GOPB
BOOSTER COMPRESSOR (FEED)

WORK ORDER NUMBER :


WO-025B

MMCOG PROJECT NUMBER : MSO-A-0088

F1 19-06-2020 Re-Approved For Bid NFT MJ


ABS ABS
CONTRACT NO. : MURPHY/S18039 F0 - Not Used - - -
FA 15-06-2020 Issued For Review NFT MJ ABS
PREPARED CHECKED APPROVED APPROVED
REV DATE REVISION DESCRIPTION
MMC MMC MMC PTTEP

Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 5 cont'd on sheet No. 6 6

Datasheet No.
: PTTEP
MY-SK309-66-IC-DS-0010
Client HK Offshore Limited (0995613W )
PTTEP Sarawak Oil Limited (993918-P) Specification No.
MY-SK309-66-ME-SP-0001
PTTEP Sabah Oil Limited (993919-M)
DATASHEET Equipment No : A-2410A/B
Equipment Name : CONTROL VALVE (TYPICAL)
CONTROL VALVE
Quantity : VTA
1 TAG NUMBER: VTA Service: BOOSTER COMPRESSOR PACKAGE
2 LINE NUMBER: VTA P&ID Number: MY-SK309-65-PR-DW-0002-01
3 FLUID: GAS NACE REQUIREMENT :
4 OPERATING CASE MIN NORMAL MAX
5 VAPOUR FLOW RATE kg/hr VTA VTA VTA
6 LIQUID FLOW RATE kg/hr VTA VTA VTA
7 INLET PRESSURE barg VTA VTA VTA
8 OUTLET PRESSURE barg VTA VTA VTA
9 DESIGN PRESSURE barg VTA VTA VTA
10 INLET TEMPERATURE °C VTA VTA VTA
11 DESIGN TEMPERATURE (MIN / MAX) °C VTA VTA VTA
12 VAPOUR DENSITY VAPOUR MOL. WT. kg/m3 - VTA VTA VTA VTA VTA VTA
FLUID DATA

13 VAPOUR VISCOSITY COMPRESS. FACTOR cP Z VTA VTA VTA VTA VTA VTA
14 SP.HEAT RATIO Cp/Cv k VTA VTA VTA
15 LIQUID DENSITY LIQUID VISCOSITY kg/m3 cP VTA VTA VTA VTA VTA VTA
16 CALCULATED VALVE COEFFICIENT (NORM. / MIN / MAX
Cv ) (NOTE 3) VTA VTA VTA
17 VALVE RATED COEFFICEINT Cv VTA VTA VTA
18 VALVE OPENING (NORM. / MIN / MAX ) % VTA VTA VTA
19 NOISE:ALLOWABLE PREDICTED (NOTE 4) dBA VTA VTA VTA VTA VTA VTA
20 CRITICAL TEMPERATURECRITICAL PRESSURE °C bar (a) VTA VTA VTA VTA VTA VTA
21 VAPOUR PRESSURE bar (a) VTA VTA VTA
22 ALLOWABLE PRESSURE DROP bar VTA VTA VTA
23 FLASHING RATE (AT VALVE OUTLET) % (VAPOUR/MASS) VTA VTA VTA
24 LINE SIZE Inlet VTA 66 TYPE VTA
25 Outlet VTA 67 MFR & MODEL NO. VTA
LINE

26 LINE SPECIFICATION / SCHEDULE VTA 68 SIZE VTA


27 INSULATION NO 69 ACTION (ON/OFF OR MODULATING) VTA
28 TYPE GLOBE 70 FAIL POSITION VTA
29 BODY SIZE VTA 71 MAX AIR SUPPLY PRESSURE VTA
30 CLASS (INLET X OUTLET) VTA 72 MIN AIR SUPPLY PRESSURE VTA
ACTUATOR

31 73 AVAILABLE AIR/GAS SUPPLY PRESSURE VTA


32 MFR & MODEL VTA 74 (NORM)
VALVE BODY / BONNET

33 BODY / BONNET MATERIAL VTA 75 BENCH RANGE VTA


34 LINE MATERIAL / ID VTA 76 ACTUATOR ORIENTATION VTA
35 END CONNECTION: Inlet VTA 77 HANDWHEEL TYPE -
36 Outlet VTA 78 STROKING TIME -
37 END EXTENSION / MATERIAL VTA 79 NO OF STEPS FOR FULL STROKE VTA
38 LUB & ISO VALVE VTA 80 FLOW ACTION TO VTA
39 BONNET TYPE VTA 81
40 SHUT-OFF PRESSURE (barg) ` 82 TYPE VTA
POSITIONER

41 MAX. ALLOWABLE SOUND LEVEL 85 dBA 83


42 GASKET VTA 84 MFR & MODEL NO. VTA
43 85 MANUAL BY-PASS NO
44 TYPE VTA 86 TAG NO. VTA
45 PORT SIZE VTA 87 TAG NO. -
SWITCHES

46 CHARACTERISTIC VTA 88 TYPE -


47 BALANCED / UNBALANCED VTA 89 MFR & MODEL NO. -
VALVE TRIM

48 TRIM MATERIAL VTA 90 CONTACTS/RATING -


49 91 ACTUATION POINTS -
50 SLEEVE MATERIAL VTA 92 MFR & MODEL NO. VTA
51 STEM MATERIAL VTA 93 SET PRESSURE VTA
52 O-RING/ PACKINGS /ELASTOMERS VTA 94 GAUGE REQUIRED
AIR SET

53 LEAKAGE CLASS: VTA 95 BODY MATERIAL: VTA


54 96 PNEUMATIC CONN. VTA
55 97 FILTER / REGULATOR VTA
56 POSITION TRANSMITTER: NO 98 TUBING 316 SS (NOTE 8)
ACCESSORIES

57 SOLENOID VALVE (OPEN/CLOSE): NO 99 HYDROTEST PRESSURE: YES


58 NO 100 YES
TESTS/CERTS

ACCUMULATOR: ANSI/FCI LEAKAGE CLASS:


59 MECHANICAL LIMIT STOP: NO 101 VALVE STROKING TEST : YES
60 HANDWHEEL: NO 102 MATERIAL CERTIFICATION: YES
61 103 HAZARDOUS AREA & INGR. PROTECTION. YES
62 AREA CLASSIFICATION ZONE 1, GAS GROUP IIA, 104 DIMENSION (INCL. ACTUATOR) YES
ENCL. CLASS

63 TEMPERATURE CLASS T3 105 MANUFACTURER VTA


64 INGRESS PROTECTION RATING IP 65 106 MODEL VTA
65 PAINTING / COATING AS PER PTS PTS 15.20.03 107 QUANTITY ONE (1)

VTA - VENDOR TO ADVISE

PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES


FOR MURPHY'S OPERATIONS

WORK ORDER TITLE :


PROVISION OF ENGINEERING WORKS FOR GOPB
BOOSTER COMPRESSOR (FEED)

WORK ORDER NUMBER

MMCOG PROJECT NUMBER :


:
WO-025B

MSO-A-0088 F1 19-06-2020 Re-Approved For Bid NFT MJ


ABS
ABS

F0 - Not Issued - - -
CONTRACT NO. : MURPHY/S18039
FA 15-06-2020 Issued For Review NFT MJ ABS
PREPARED CHECKED APPROVED APPROVED
REV DATE REVISION DESCRIPTION
MMC MMC MMC PTTEP
6 7
Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No cont'd on sheet No.

Datasheet No.
MY-SK309-66-IC-DS-0010
Client : PTTEP HK Offshore Limited (0995613W)
PTTEP Sarawak Oil Limited (993918-P) Specification No.
MY-SK309-66-ME-SP-0001
PTTEP Sabah Oil Limited (993919-M)
DATASHEET Equipment No : A-2410A/B
Equipment Name : PRESSURE TRANSMITTER (TYPICAL)
PRESSURE TRANSMITTER
Quantity : VTA

GENERAL NOTES :

1. EACH INSTRUMENT SHALL HAVE A 20 mm x 75 mm, GAUGE 316 SS TAG PLATE WITH TAG NUMBER AND PLANT NAME ENGRAVED OR EMBOSSED
IN 6 mm HIGH x 0.3 mm DEEP BOLD CHARACTERS. THE TAG PLATE SHALL BE PERMANENTLY ATTACHED TO THE INSTRUMENT WITH SS WIRE.
ACCESSORIES LIKE POSITIONER, ETC. SHALL BE TAGGED E.G. FY/PY/LY-XXXX. WHERE XXXX INDICATES THE SAME TAG AS CONTROL VALVE TAG NO.

2. CONTROL VALVES SHALL MEET DESIGN PRESSURE AND TEMPERATURE RATING AS INDICATED IN INDIVIDUAL VALVE DATA SHEET. VENDOR IS
CAUTIONED AGAINST SUBSTITUTION OF MATERIALS, EVEN SUPERIOR MATERIAL LIKE 316 SS IN PLACE OF LOW TEMP CARBON STEEL, WHICH
MAY NOT MEET THE DESIGN PRESSURE AND TEMPERATURE REQUIREMENTS.

3. THE CALCULATED AND RATED Cv VALUES IN THE DATASHEET ARE INDICATIVE ONLY.
VENDOR SHALL VERIFY AND SHALL BE RESPONSIBLE FOR THE SIZING AND SELECTION OF VALVE AND ACTUATOR. VENDOR SHALL SUBMIT
ALL CALCULATIONS PERTAINING TO THESE FOR PURCHASER'S APPROVAL AND ALSO AS PART OF FINAL DOCUMENTATION. VENDOR SHALL BE
RESPONSIBLE FOR OBTAINING ANY NECESSARY DATA FROM PURCHASER.

4. VENDOR IS REQUIRED TO SUBMIT NOISE CALCULATIONS TO ESTABLISH THAT THE SOUND LEVEL MEETS THE REQUIREMENT AT SPECIFIED OPERATING
AND MAXIMUM CONDITIONS.

5. WHERE EVER MORE THAN ONE CASE OR CONDITION IS SPECIFIED, VALVE SHALL BE CAPABLE OF HANDLING ALL THE CASES / CONDITIONS.

6. VENDOR SHALL ENSURE THAT HARDENED TRIMS ARE PROVIDED WHENEVER FLASHING OR CAVITATION OCCURS OR NECESSITATED BY PROCESS
CONDITIONS. STELLITE COATING OF SEAT AND PLUG, WHERE PROVIDED FOR HARDENED TRIM, SHALL COVER THE ENTIRE SEAT AND PLUG SURFACE.
HARDENED GUIDE POST, IF REQUIRED DUE TO SERVICE CONDITIONS OR IF SPECIFIED IN DATA SHEETS SHALL ALSO BE PROVIDED WITH STELLITE COATING.
VENDOR TO ENSURE WETTED PART/TRIM MATERIAL SHALL BE SUITABLE FOR THE PROCESS FLUID.

7. THE SURFACE FINISH OF RAISED FACE FLANGE SHALL BE SMOOTH FINISH TO SURFACE ROUGHNESS OF 125µinch TO 250 µinch AS PER ANSI/ASME B16.5.

8. ALL ACCESSORIES LIKE POSITIONER, REGULATOR, ETC. SHALL BE MOUNTED ON THE CONTROL VALVE AND TUBED BY VENDOR USING
316L SS TUBING. MINIMUM TUBE SHALL BE 1/2" O.D. x 0.035" WT. HARDNESS SHALL NOT EXCEED 80 Rb. ALL TUBE FITTINGS SHALL BE 316 SS

9. NOMINAL INSTRUMENT AIR SUPPLY PRESSURE IS 7.6 barg . INPUT SIGNAL TO THE SMART POSITIONER
SHALL BE 4-20mA WITH SUPERIMPOSED DIGITAL SIGNAL BASED ON HART PROTOCOL AND OUTPUT SIGNAL FROM THE SMART POSITIONER SHALL BE AS
REQUIRED TO MATCH THE ACTUATOR REQUIREMENT FOR MAX. SHUTOFF DIFFERENTIAL PRESSURE.

10. THE REGULATOR / ACTUATOR SHALL BE SUITABLE FOR A DESIGN PRESSURE OF 13.5 barg. MATERIALS OF CONSTRUCTION FOR BODY, SPRING CASE
AND BOWL SHALL BE 316 SS AND FITTED WITH PRESSURE OUTPUT GAUGE IN "barg" AND "kpag".

11. ALL CONTROL VALVES SHALL BE PROVIDED WITH A STEM POSITION TRAVEL INDICATOR.

12. WHEREVER '316 SS' IS SPECIFIED FOR COMPONENTS, 316L SS SHALL BE UTILISED IF WELDED CONSTRUCTION IS EMPLOYED.

13. ALL ELECTRICAL ITEMS LIKE SMART POSITIONERS, ETC SHALL BE INSTRINSICALLY SAFE FOR USE IN ZONE 1 GAS GROUP IIA TEMPERATURE CLASS T3
HAZARDOUS AREA. ELECTRICAL CONNECTION SHALL BE ISO M20. ALL ELECTRICAL ITEMS SHALL MEET THE REQUIREMENT OF IEC 60079
CERTIFIED BY IECEx. IF NOT AVAILABLE, ATEX DIRECTIVE 94/9/EC CERTIFICATION OR EQUIVALENT STANDARDS IS ACCEPTED.

14. CONTROL VALVES SHALL COMPLY WITH THE REQUIREMENTS SPECIFIED IN PTS 14.10.04 AND ITS SUPPLEMENTARY.

15. AS A GENERAL BEST PRACTICE, THE MINIMUM FLANGE RATING FOR THE CONTROL VALVE BODY SHOULD BE ANSI 600 LBS AS PER PTS 14.10.04
SECTION 3.2.7.

16. ABBREVIATIONS:
VTA - VENDOR TO ADVISE
TBD - TO BE DETERMINED
N/A - NOT APPLICABLE

PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES


FOR MURPHY'S OPERATIONS

WORK ORDER TITLE :


PROVISION OF ENGINEERING WORKS FOR GOPB
BOOSTER COMPRESSOR (FEED)

:
ABS
WORK ORDER NUMBER WO-025B

F1 19-06-2020 Re-Approved For Bid NFT MJ ABS


MMCOG PROJECT NUMBER : MSO-A-0088

F0 - Not Issued - - -

CONTRACT NO. : MURPHY/S18039


FA 15-05-2020 Issued For Review NFT MJ ABS

PREPARED CHECKED APPROVED APPROVED


REV DATE REVISION DESCRIPTION
MMC MMC MMC PTTEP
Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 7 cont'd on sheet No. 8

Datasheet No.
MY-SK309-66-IC-DS-0010
Client : PTTEP HK Offshore Limited (0995613W )
PTTEP Sarawak Oil Limited (993918-P) Specification No.
MY-SK309-66-ME-SP-0001
PTTEP Sabah Oil Limited (993919-M)
DATASHEET Equipment No : A-2410A/B
Equipment Name : PRESSURE TRANSMITTER (TYPICAL)
PRESSURE TRANSMITTER
Quantity : VTA

HOOK-UP SCHEMATIC SK/IN/0001

INPUT FROM UCP

INSTRUMENT I/P
AIR SUPPLY

D
B
CONTROL
VALVE
CV-XXX

VENDOR'S SCOPE OF SUPPLY

INSTRUMENT BILL OF MATERIAL (NOTE 1)

ITEM
DESCRIPTION (NOTE 2) MATERIAL SIZE QUANTITY
No.
A INSTRUMENT AIR FILTER REGULATOR (NORGREN OR EQUAL) AISI 316 BY VENDOR 1
B TUBING SEAMLESS FULLY ANNEALED TO ASTM A269 WITH MO CONTENT > 2.5% 316L SS 3/8" OD x 0.065" W.T. 1
C BALL VALVE, SCREWED 316 SS BY VENDOR 1
D MALE CONNECTOR 316 SS BY VENDOR 2

NOTES:
1. THE ABOVE BILL OF MATERIAL IS FOR ONE INSTALLATION. VENDOR SHALL SUPPLY ALL NECESSARY ADAPTOR/FITTING TO COMPLETE
THE INSTALLATION AS REQUIRED.
2. SEE GENERAL NOTES ON DATASHEET SHT.4.
3. THIS SCHEMAITC DRAWING IS INDICATIVE ONLY.

PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES


FOR MURPHY'S OPERATIONS

WORK ORDER TITLE :


PROVISION OF ENGINEERING WORKS FOR GOPB
BOOSTER COMPRESSOR (FEED)

ABS
WORK ORDER NUMBER :
WO-025B

F1 19-06-2020 Re-Approved For Bid NFT MJ ABS


MMCOG PROJECT NUMBER : MSO-A-0088

F0 - Not Issued - - -

CONTRACT NO. : MURPHY/S18039 FA 15-05-2020 Issued For Review NFT MJ ABS


PREPARED CHECKED APPROVED APPROVED
REV DATE REVISION DESCRIPTION
MMC MMC MMC PTTEP
Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 8 cont'd on sheet No. 9

Datasheet No.
MY-SK309-66-IC-DS-0010
Client : PTTEP HK Offshore Limited (0995613W )
PTTEP Sarawak Oil Limited (993918-P) Specification No.
MY-SK309-66-ME-SP-0001
PTTEP Sabah Oil Limited (993919-M)
DATASHEET Equipment No : A-2410A/B
Equipment Name : PRESSURE GAUGE (TYPICAL)
PRESSURE GAUGE
Quantity : VTA

1 Tag Number VTA


2 Service BOOSTER COMPRESSOR PACKAGE
GENERAL
3 P&ID No. MY-SK309-65-PR-DW-0002-01
4 Line No. Equipment No. VTA VTA
5 Fluid description VTA
6 Oper. Press. barg 10.5
PROCESS CONDITION 7 Oper. Temp. °C AMBIENT
8 Design Press. barg 13
9 Design Temp. (Min./Max) °C 65 (MAX)
10 Type LOCAL, DIRECT READING
11 Instrument Range Min. Max. barg 0 TO 16
12 Scale Graduation & Color BARG & PSIG VTA
13 Mounting DIRECT
14 Dial Size Dial Material 100mm (VTA)
15 Dial Color WHITE BACKGROUND WITH BLACK LETTER
16 Case Type Case Material SOLID FRONT 316 SS
17 Ring Construction Ring Material BAYONET 316 SS
18 Blow-Out Protection BACK BLOW OUT PLATE
19 Window Material SAFETY LAMINATED AND SHATTERPROOF GLASS
GAUGE
20 Pressure Element Type BOURDON TUBE
21 Pressure Element Material MONEL
22 Socket & Wetted Part Material MONEL
23 Process Connection Size 1/2" NPTM
24 Process Connection Location BOTTOM
25 Movement Material
26 Nominal Accuracy Grade ±1% of full scale
27 Enclosure Class IP 65
28 Zero Adjustment YES
29 Overrange Protection 130% of FULL SCALE
30 Type -
31 Process Connection & Rating -
32 Diaphragm Material -
33 Wetted Part Material -
34 Fill Fluid -
DIAPHRAGM SEAL
35 Capillary Length -
36 Capillary Material -
37 Gauge Connection -
38 Mounting Accessories / Brackets -
39
40 Liquid Filled Casing NO
41 Valve Manifold Type & Material -
42 Gauge Saver Syphon (VTA) GENERAL NOTE 8 -
OPTIONS
43 Snubber Overall Length - VTA
44 Certification REQUIRED
45 Remarks -
46 Manufacturer WIKA, ASHCROFT OR PCSB APPROVED EQUAL
PURCHASE
47 Model No. VTA
NOTES:
1. REFER SECTION 3 FOR GENERAL NOTES.

VTA - VENDOR TO ADVISE

PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES


FOR MURPHY'S OPERATIONS

WORK ORDER TITLE :


PROVISION OF ENGINEERING WORKS FOR GOPB
BOOSTER COMPRESSOR (FEED)

ABS
WORK ORDER NUMBER :
WO-025B

F1 19-06-2020 Re-Approved For Bid NFT MJ ABS


MMCOG PROJECT NUMBER : MSO-A-0088
F0 - Not Issued - - -

CONTRACT NO. : MURPHY/S18039 FA 15-06-2020 Issued For Review NFT MJ ABS

PREPARED CHECKED APPROVED APPROVED


REV DATE REVISION DESCRIPTION
MMC MMC MMC PTTEP
Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 9 cont'd on sheet No. 10

Datasheet No.
MY-SK309-66-IC-DS-0010
Client : PTTEP HK Offshore Limited (0995613W )
PTTEP Sarawak Oil Limited (993918-P) Specification No.
MY-SK309-66-ME-SP-0001
PTTEP Sabah Oil Limited (993919-M)
DATASHEET Equipment No : A-2410A/B
Equipment Name : PRESSURE GAUGE (TYPICAL)
PRESSURE GAUGE
Quantity : VTA

GENERAL NOTES :

1. EACH PRESSURE GAUGE SHALL HAVE 30 MM X 75 MM GAUGE THICKNESS 316SS TAG PLATE WITH TAG NUMBER
AND SERVICE ENGRAVED OR EMBOSSED IN 6 MM HIGH X 0.3 MM DEEP BOLD CHARACTERS. THE TAG PLATE SHALL BE
PERMANENTLY ATTACHED TO THE INSTRUMENT WITH SS WIRE.

2. ALL PRESSURE GAUGES SHALL HAVE MICROMETER POINTERS AND WHITE ALUMINIUM DIALS WITH BLACK NUMERALS AND MARKING FOR
PRIMARY SCALE AND RED FOR SECONDARY SCALE.

3. ALL PRESSURE GAUGES SHALL HAVE DUAL SCALE (barg AND psig) , MAIN INDICATION SHALL BE IN barg. SECONDARY INDICATION
SHALL BE IN psig.

4. ALL PRESSURE GAUGE SHALL BE DRY, ANTI-VIBRATION TYPE AND WITHOUT LIQUID FILLED.

5. ALL GAUGES SHALL BE DESIGNED TO WITHSTAND OVERPRESSURES UP TO 130% OF FULL SCALE WITHOUT
AFFECTING THE CALIBRATION.

6. BOURDON TUBE SHALL BE OF THE SAFETY PATTERN IN ACCORDANCE WITH BS EN 837-1.

7. ALL PRESSURE GAUGE LENS SHALL BE IMPACT RESISTANCE, UV PROOF, SHATTER PROOF AND HEAVY DUTY ETC.

8. PRESSURE LIMIT VALVE (GAUGE SAVER) SHALL BE PROVIDED IF 130% OF GAUGE FULL SCALE IS LESS THAN PROCESS DESIGN PRESSURE.
GAUGE SAVER SHALL BE 316 SS. 1/2" NPTM INLET X 1/2" NPTF OUTLET AND SHALL BE IN ACCORDANCE WITH ASME B-40.6 - 2001
THE MATERIAL SHALL BE THE SAME AS THE ELEMENT.

9. HOUSING PROTECTION SHALL BE IN ACCORDANCE WITH IP-65 OF IEC 60529 AS A MINIMUM.

10. PRESSURE GAUGES SHALL BE CALIBRATED (5 POINT IN COMPLETE RANGE) BY CERTIFIED CALIBRATION EQUIPMENT.
CALIBRATION CERTIFICATES SHALL BE AVAILABLE WITH FINAL DOCUMENTS.

11. PRESSURE GAUGE DESIGN, CONSTRUCTION & TESTING SHALL AS PER ASME B40.100

12. THE FOLLOWING TESTS SHALL BE REQUIRED FOR THE PRESSURE GAUGE :

i) FUNCTIONAL TEST
ii) VISUAL AND DIMENSIONAL TEST
iii) CALIBRATION
iv) HYDROTEST
v) MATERIAL CERTIFICATE AS PER EN 10204
- TYPE 3.1 FOR PRESSURE RETAINING PARTS NON SOUR SERVICE
- TYPE 3.2 FOR PRESSURE RETAINING PARTS SOUR SERVICE
- TYPE 2.2 FOR NON-PRESSURE RETAINING PARTS

PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES


FOR MURPHY'S OPERATIONS

WORK ORDER TITLE :


PROVISION OF ENGINEERING WORKS FOR GOPB
BOOSTER COMPRESSOR (FEED)

:
ABS
WORK ORDER NUMBER WO-025B

F1 19-06-2020 Re-Approved For Bid NFT MJ ABS


MMCOG PROJECT NUMBER : MSO-A-0088
F0 - Not Issued - - -

FA 15-05-2020 Issued For Review NFT MJ ABS


CONTRACT NO. : MURPHY/S18039
PREPARED CHECKED APPROVED APPROVED
REV DATE REVISION DESCRIPTION
MMC MMC MMC PTTEP
Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 10 cont'd on sheet No. 11

Datasheet No.
MY-SK309-66-IC-DS-0010
Client : PTTEP HK Offshore Limited (0995613W )
PTTEP Sarawak Oil Limited (993918-P) Specification No.
MY-SK309-66-ME-SP-0001
PTTEP Sabah Oil Limited (993919-M)
DATASHEET Equipment No : A-2410A/B
Equipment Name : PRESSURE TRANSMITTER (TYPICAL)
PRESSURE TRANSMITTER
Quantity : VTA
1 Tag Number VTA
2 Service BOOSTER COMPRESSOR PACKAGE
3 Line No. Equipment No. VTA VTA
4 P&ID No. MY-SK309-65-PR-DW-0002-01
GENERAL
5 Function Indicate and transmit
6 Mounting DN50 pipe mounted
7 Area Classification Zone 1, Gas Group IIA, T3
8 Certification Enclosure Class Ex'd' IP 66
9 Fluid Fluid State HC LIQUID LIQUID
10 Oper. Press. bar-g VTA
PROCESS CONDITIONS 11 Oper. Temp. °C VTA
12 Design Press. bar-g VTA
13 Design Temp. °C VTA
14 Type Measurement SMART Transmitter Gauge Pressure
15 Instr. Range Min. Max. bar-g (*) (*)
16 Calib. Range Min. Max. bar-g VTA VTA
17 Power Supply 2-wire, 24V DC, Loop powered
18 Transmitter Output 4-20 mA with HART
19 Accuracy Rating ±0.1% of calibrated span
20 Element Type Element Material Diaphragm 316 SS
21 Mounting Kit Material 316 SS
SENSOR &
22 Fill Fluid (*)
TRANSMITTER
23 Housing Material 316 SS
24 Overrange Protection 150% of design pressure
25 Process Connection Electrical Connection 1/2" NPTM ISO M20 x 1.5
26 Bolts/Nuts Material 316 SS
27 Wetted Part Material 316 SS
28
29
30
31 Process Connection & Rating -
32 Diaphragm Material -
33 Housing Material Upper Lower - -
34 Fill Fluid Capillary Material - -
DIAPHRAGM SEAL 35 Capillary Type Capillary Length - -
36 Capillary Diameter Armour Material - -
37 Flushing Connection Drip Ring Material - -
38 Gasket / O-Ring Material -
39 Manufacturer Model - -
40 Integral LCD Indicator Scale Yes, with engineering unit bar-g
41 Mounting Brackets Yes for DN50 pipe mounting
42 Valve Manifold Material 2-way valve 316 SS
OPTIONS
43 Testing & Certification Required
44 SIL Rating -
45 Remarks -
46 Manufacturer (*)
PURCHASE
47 Model No. (*)

NOTES:
1. REFER SHEET 6 FOR GENERAL NOTES.
2. (*) DENOTES VENDOR TO CONFIRM/SPECIFY.
VTA - VENDOR TO ADVISE

PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES


FOR MURPHY'S OPERATIONS

WORK ORDER TITLE :


PROVISION OF ENGINEERING WORKS FOR GOPB
BOOSTER COMPRESSOR (FEED)

ABS
WORK ORDER NUMBER :
WO-025B

F1 19-06-2020 Re-Approved For Bid NFT MJ ABS


MMCOG PROJECT NUMBER : MSO-A-0088 F0 - Not Issued - - -

FA 15-06-2020 Issued For Review NFT MJ ABS


CONTRACT NO. : MURPHY/S18039
PREPARED CHECKED APPROVED APPROVED
REV DATE REVISION DESCRIPTION
MMC MMC MMC PTTEP
Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 11 cont'd on sheet No. # 12

Datasheet No.
MY-SK309-66-IC-DS-0010
Client : PTTEP HK Offshore Limited (0995613W )
PTTEP Sarawak Oil Limited (993918-P) Specification No.
MY-SK309-66-ME-SP-0001
PTTEP Sabah Oil Limited (993919-M)
DATASHEET Equipment No : A-2410A/B
Equipment Name : PRESSURE TRANSMITTER (TYPICAL)
PRESSURE TRANSMITTER
Quantity : VTA

GENERAL NOTES :

1. EACH INSTRUMENT SHALL HAVE A 30 MM X 75 MM, 20 GAUGE 316SS TAG PLATE WITH PURCHASERS TAG NUMBER ENGRAVED IN 6 MM HIGH X 0.3 MM DEEP
BOLD CHARACTERS. THE TAG PLATE SHALL BE PERMANENTLY ATTACHED TO THE INSTRUMENT BY MEANS OF SCREW, BOLT OR RIVETING. AN ADDITIONAL
316 SS TAG PLATE WITH SS WIRE SHALL BE PERMANENTLY ATTACHED TO THE INSTRUMENT.

2. TRANSMITTER SHALL BE PROVIDED WITH 5-DIGIT LCD DIGITAL METER SHOWING THE PRESSURE IN ENGINEERING UNITS BARG AND PSIG.

3. THE ELECTRONIC TRANSMITTER CIRCUITS SHALL ENSURE SYSTEM CONTINUITY IN CASE OF LOCAL LCD INDICATOR FAILURE OR REMOVAL.

4. TRANSMITTER OUTPUT SHALL BE ANALOG 4-20MA AND SUPERIMPOSED DIGITAL SIGNAL BASED ON ,HART, PROTOCOL. TRANSMITTER CONFIGURATION
AND CALIBRATION SHALL BE POSSIBLE FROM THE PCS OR BY HANDHELD PROGRAMMER.

5. ALL PRESSURE TRANSMITTERS SHALL BE PROVIDED WITH CRIPPLED MODE DETECTION AS PER NAMUR-NE 43.

6. CABLE ENTRY SHALL BE ISO M20X1.5 AND SPARE ENTRY SHALL BE PLUGGED WITH EX,D, CERTIFIED SS PLUG.

7. THE TRANSMITTER AND VALVE MANIFOLD SHALL BE ABLE TO WITHSTAND 150% OF DESIGN PRESSURE.

8. VENDOR SHALL SPECIFY INSTRUMENT RANGE FOR EACH TRANSMITTER.

9. VENDOR SHALL PROVIDE 316 SS, UNIVERSAL MOUNTING BRACKETS, U-BOLTS, NUTS AND ACCESSORIES TO SUIT DN50 PIPE FOR REMOTE MOUNTING.

10. VENDOR SHALL PROVIDE 2-WAY VALVE MANIFOLD FOR EACH TRANSMITTER. VALVE MANIFOLD CONNECTION SHALL HAVE
1/2" NPTF PROCESS CONNECTION.

11. DOCUMENTATION:
VENDOR TO FURNISH CALIBRATION CERTIFICATE, HYDROTESTING CERTIFICATE, IP CERTIFICATE, MATERIAL CERTIFICATE, SIL CERTIFICATE AND
HAZARDOUS AREA CLASSIFICATION CERTIFICATION AS A MINIMUM.

12. VENDOR SHALL PROVIDE LIST OF TWO YEARS OPERATIONAL SPARES AS PER ATTACHED SPIR FORM.

13. THE MATERIAL OF CONSTRUCTION SHALL BE SUITABLE FOR THE MOST EXTREME UPSTREAM AND DOWNSTREAM CONDITIONS AS STATED IN DATA SHEET
AND SHALL ALSO BE SUITABLE FOR USE IN SALINE OFFSHORE ENVIRONMENT. HOUSING PROTECTION SHALL BE IN ACCORDANCE WITH IP 66 OF IEC 60529
AS A MINIMUM.

PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES


FOR MURPHY'S OPERATIONS

WORK ORDER TITLE :


PROVISION OF ENGINEERING WORKS FOR GOPB
BOOSTER COMPRESSOR (FEED)

:
ABS
WORK ORDER NUMBER WO-025B

F1 19-06-2020 Re-Approved For Bid NFT MJ ABS


MMCOG PROJECT NUMBER : MSO-A-0088 F0 - Not Issued - - -

FA 15-05-2020 Issued For Review NFT MJ ABS


CONTRACT NO. : MURPHY/S18039
PREPARED CHECKED APPROVED APPROVED
REV DATE REVISION DESCRIPTION
MMC MMC MMC PTTEP
Eng. By : MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 12 cont'd on sheet No. 13

Datasheet No.
MY-SK309-66-IC-DS-0010
Client : PTTEP HK Offshore Limited (0995613W )
PTTEP Sarawak Oil Limited (993918-P) Specification No.
MY-SK309-66-ME-SP-0001
PTTEP Sabah Oil Limited (993919-M)
DA TA SHEET Eq u ip m en t No : A -2410A /B
Eq u ip m en t Nam e : REL IEF VA L VE (TYPICA L )
RELIEF VALVE
Qu an t it y : VTA

1. TAG NUMBER VTA

2. SERVICE BOOSTER COMPRESSOR PACKAGE


3. LINE NO. / VESSEL NO. P&ID NO. VTA MY-SK309-66-PR-DW-0002
GENERAL 4. FULL NOZZLE / SEMI NOZZLE FULL NOZZLE

5. SAFETY OR RELIEF RELIEF

6. CONV. / BELLOWS ,/ PILOT OPERATED CONVENTIONAL

7. BONNET TYPE CLOSED

8. SIZE INLET OUTLET VTA VTA


CONNECTION 9. FLANGE RATING INLET OUTLET VTA VTA

10. TYPE OF FACING INLET OUTLET RF, SMOOTH FACE RF, SMOOTH FACE

11. BODY AND BONNET VTA

12. SEAT AND DISC VTA

13. RESILIENT SEAT SEAL VTA


MATERIALS
GUIDE AND RINGS VTA
(NOTE 4) 14.
15. SPRING VTA

16. BELLOWS -

17. NOZZLE VTA

18. CAP: SCREWED OR BOLTED SCREWED

19. LEVER: PLAIN OR PACKED N/A

20. TEST CONNECTION N/A


OPTIONS
21. NO FLOW PILOT N/A

22. PILOT FILTER N/A

23. BACKFLOW PERVENTER N/A

24. CODE VTA


BASIS 25. FIRE -

26. OTHER -

27. FLUID HC GAS

28. FLUID STATE HYDROCARBON GAS

29. RELIEVING CAPACITY (GAS/MIXED LIQ) (kg/h) VTA


30. MOL. WEIGHT (GAS) DENSITY (GAS/ MIXED LIQ) (kg/m3) VTA VTA

31. OPR. PRESSURE (barg) SET PRESSURE (barg) VTA VTA

32. OPR. TEMPERATURE (oC) REL. TEMPERATURE (°C) VTA VTA

BUILT UP BACK PRESSURE (barg) VTA


33.
34. SUPERIMPOSED BACK PRESSUR: CONSTANT (barg) VTA

FLUID DATA VARIABLE (barg) VTA

35. SYSTEM DESIGN PRESSURE / TEMPERATURE (barg) / (°C) VTA

36. % ALLOWABLE OVERPRESSURE VTA

37. OVERPRESSURE FACTOR VTA

38. COMPRESSIBILITY FACTOR VTA

39. LATENT OF HEAT OF VAPORISED VTA

40. RATIO OF SPECIFIC HEATS (Cp/Cv) VTA

41. OPERATING VISCOSITY (GAS/ LIQ/WATER) (cP) VTA

42. BAROMETRIC PRESSURE (bara) VTA

43 SPECIFIC VOLUME @ 90% OF PSV INLET (m3/kg) VTA

44. SPECIFIC VOLUME OF TWO PHASE AT PSV INLET (m3/kg) VTA

45. CALC. AREA (SQ.IN) VTA

46. SELECTED AREA (SQ.IN) VTA

47. ORIFICE DESIGNATION VTA

48. MANUFACTURER VTA

49. MODEL NUMBER VTA


50. QUANTITY OF VALVE(S) 1 (ONE)

VTA - VENDOR TO ADVISE

PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES


FOR MURPHY'S OPERATIONS

WORK ORDER TITLE : PROVISION OF ENGINEERING WORKS FOR GOPB


BOOSTER COMPRESSOR (FEED)

WORK ORDER NUMBER : WO-025B


F1 19-06-2020 Re-Approved For Bid NFT MJ
ABS
ABS
MMCOG PROJECT NUMBER : MSO-A-0088 F0 - Not Used NFT MJ ABS
FA 15-06-2020 Issued For Review NFT MJ ABS
PREPARED CHECKED APPROVED APPROVED
MURPHY/S18039 REV DATE REVISION DESCRIPTION
CONTRACT NO. : MMC MMC MMC PTTEP
MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 13 cont'd on sheet No. 14
Eng. By :
Datasheet No.
MY-SK309-66-IC-DS-0010
Client : PTTEP HK Offshore Limited (0995613W )
PTTEP Sarawak Oil Limited (993918-P) Specification No.
MY-SK309-66-ME-SP-0001
PTTEP Sabah Oil Limited (993919-M)
DA TA SHEET Eq u ip m en t No : A -2410A /B
Eq u ip m en t Nam e : TEM PERA TURE TRA NSM ITTER (TYPICA L )
TEMPERATURE TRANSMITTER
Qu an t it y : VTA

1. FUNCTION RECORD [ ] INDICATE [X] CONTROL [ ] BLIND [ ] TRANS. [X]


OTHER:
2. CASE MFR STD [ ] OTHER: 316 SS NOM SIZE: COLOR: MFR STD [X] OTHERS:
GENERAL 3. MOUNTING FLUSH [ ] SURFACE [ ] YOKE [ ] OTHER : DIRECT (GEN. NOTE 3)
4. ENCLOSURE CLASS GENERAL PURPOSE [ ] WEATHER PROOF [X] EXPLOSION PROOF [ ] CLASS: IP65 OF IEC 60529
FOR USE IN INTRINSICALLY SAFE SYSTEM [X] OTHER: AREA CLASS - IEC ZONE 1, GR IIA, CLASS T3
5. POWER SUPPLY 117V 60 HZ [ ] OTHER AC: DC [X] 24 VOLTS 2-WIRE TRANSMISSION SYSTEM (LOOP POWERED)

6. TRANSMITTER 4-20 mA [X] 10-50 mA [ ] 21-103 kPa [ ] OTHER:DIGITAL DISPLAY (GEN. NOTE 4)
TRANSMITTER7. OUTPUT ACCURACY: ±0.1% OF CALIBRATED SPAN
8. FILL SAMA CLASS:
9. PROCESS DATA TEMP: NORMAL REFER TABLE BELOW° C DESIGN REFER TABLE BELOW °C DESIGN PRESS.: REFER TABLE BELOW
10. RANGE FIXED [ ] ADJ. RANGE: SET AT:
OVERRANGE PROTECTION TO:
11. BULB/SENSOR TYPE: 3-WIRE RTD (GEN. NOTE 5) MATL: PT-100 @ 0ºC TYPE: SPRING-LOADED, SINGLE ELEMENT
SIZE: TO SUIT THERMOWELL LENGTH: TO SUIT THERMOWELL INSERTION: TO SUIT THERMOWELL
ELEMENT CONN: LOCATION: FT. ABOVE [ ] BELOW [ ]
12. CAPILLARY MFR STD [ ] LENGTH: MATL.: ARMOUR:
13. WELL NONE [ ] INCLUDED [X] BY OTHER [ ] CONN:
MATERIAL: 304SS [ ] 316SS [ ] 316LSS [ ] OTHERS: VTA
CONSTRUCTION: DRILLED [X] BUILT-UP [ ] TAPERED [X] OTHERS:REFER TABLE BELOW
STEM CONNECTION : VTA LAG EXT.:
PROCESS CONNECTION: VTA
14. ALARM SWITCHES QUANTITY: FORM: RATING:
15. FUNCTION TEMP. [ ] DEVIATION[ ] CONTACTS TO ON TEMP. INCREASE

16. OPTIONS FILT-REG. [ ] SUP GAGE [ ] INTEGRAL OUTPUT METER [X] 4 DIGIT LCD DIGITAL METER, ENG. UNIT (°C)
OTHER:
17. MFR. & MODEL NO. EMERSON, YOKOGAWA OR EQUAL
OPERATING DESIGN
P&ID TEMP PRESS. TEMP PRESS.
'L' STD T/W
(MY- RANGE °C Barg °C Barg FLUID VELOCITY REMARKS
NO. TAG NO. SERVICE LENGTH CONSTRU DENSITY
SK309-66- (°C) (m/s) (NOTES)
mm CTION (kg/m3)
PR-DW-) Min / Min /
Min / Max Min / Max
Max Max

1 VTA 0002 BOOSTER COMPRESSOR VTA VTA VTA VTA VTA VTA TAPERED VTA VTA

VTA - VENDOR TO ADVISE

PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES


FOR MURPHY'S OPERATIONS

WORK ORDER TITLE : PROVISION OF ENGINEERING WORKS FOR GOPB


BOOSTER COMPRESSOR (FEED)

WORK ORDER NUMBER : WO-025B


F1 19-06-2020 Re-Approved For Bid NFT MJ ABS
ABS
MMCOG PROJECT NUMBER : MSO-A-0088 F0 - Not Used NFT MJ ABS
FA 15-06-2020 Issued For Review NFT MJ ABS
PREPARED CHECKED APPROVED APPROVED
MURPHY/S18039 REV DATE REVISION DESCRIPTION
CONTRACT NO. : MMC MMC MMC PTTEP
MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 14 cont'd on sheet No. 15
Eng. By :
Datasheet No.
MY-SK309-66-IC-DS-0010
Client : PTTEP HK Offshore Limited (0995613W )
PTTEP Sarawak Oil Limited (993918-P) Specification No.
MY-SK309-66-ME-SP-0001
PTTEP Sabah Oil Limited (993919-M)
DA TA SHEET Eq u ip m en t No : A -2410A /B
Eq u ip m en t Nam e : TEM PERA TURE TRA NSM ITTER (TYPICA L )
TEMPERATURE TRANSMITTER
Qu an t it y : VTA

NOTES :

1
EACH INSTRUMENT SHALL HAVE 30 mm X 75 mm, 20 GAUGE 316 SS TAG PLATE WITH TAG NUMBER AND SERVICE ENGRAVED OR EMBOSSED IN 6mm HIGH X 0.3mm DEEP
.
BOLD CHARACTERS. THE TAG PLATE SHALL BE PERMANENTLY ATTACHED TO THE INSTRUMENT WITH SS WIRE.

2
THERMOWELL TAG NUMBER SHALL BE TW-XXXX WHERE XXXX IS SAME AS TG TAG NUMBER. THERMOWELL SHALL BE DRILLED FROM SOLID BAR. THERMOWELL SHALL
.
HAVE 1/2" NPTF SENSOR CONNECTION.

3
TRANSMITTER AND SENSOR SHALL BE SUPPLIED AS A COMPLETE SINGLE ASSEMBLY.
.
4
OUTPUT SHALL BE 4-20mA WITH SUPERIMPOSED DIGITAL SIGNAL BASED ON HART PROTOCOL. TRANSMITTER SHALL BE PROVIDED WITH
.
INTEGRAL 4-DIGIT LCD DIGITAL METER SHOWING THE TEMPERATURE IN ENGINEERING UNITS (˚C).

5
HEAD EXTENSION, LOCKNUT, ETC SHALL BE 316 SS.
.

6. VENDOR SHALL FURNISH THERMOWELL CALCULATIONS ACCORDING TO ASME PTC 19.3 TW-2016. VENDOR SHALL VERIFY THAT THE THERMOWELL WILL BE FIT FOR SERVICE
AND SATISFIES CRITERIAS MENTIONED BY THE STANDARD SUCH AS FREQUENCY LIMIT, DYNAMIC AND STATIC STRESS LIMITS, HYDROSTATIC PRESSURE LIMIT ETC. IF
CALCULATIONS YIELD ANY UNSATISFACTORY RESULT, VENDOR SHALL RECOMMEND SOLUTIONS e.g. SHORTER INSERTION LENGTH, INCREASE TIP DIAMETER OR OTHERS
(SPIRAL TYPE THERMOWELL OR ETC.) SUBJECT TO PURCHASER APPROVAL. THE USE OF VELOCITY COLLAR HOWEVER, IS NOT ACCEPTABLE AS IT IS NOT RECOMMENDED
AND OUTSIDE THE SCOPE OF ASME PTC 19.3 TW-2016.
HOWEVER, VENDOR TO FOLLOW PCSB TECHNICAL ALERT NO : DEIC/ITA-20026/23 JULY 2014 FOR THERMOWELL SUPPLIED. THE CONCLUSION OF TECHNICAL ALERT AS FOLLOW:
1. REQUIREMENT IN PTS 20.078 ON THE THERMOWELL NATURAL TO VORTEX INDUCED FREQUENCIES RATIO AS STIPULATED IN SECTION 4.3.4 TO BE DISCONTINUED
2. COMPLIANCE WITH ASME PTC 19.3 (2016) WITH FOLLOWING AMENDMENTS:
i. EXCEPTION STIPULATED IN SECTION 6-8.5 NOT TO BE USED UNDER ANY CIRCUMTANCES
ii. RECOMMENDATION IN SECTION 6-8.4 i.e. 0.6< fs / fn < 0.8 OR fs/fn < 0.4 TO BE MADE MANDATORY

7. STANDARD LAP FLANGE FOR HOLDING THE THERMOWELL AT THE PIPING FLANGE SHALL BE 316 SS AND SUPPLIED BY VENDOR.
THE LAP FLANGE SIZE AND RATING SHALL BE AS PER THERMOWELL's PROCESS CONNECTION.

8. TRANSMITTER SHALL BE INTRINSICALLY SAFE (Ex'ia') CERTIFIED SUITABLE FOR ZONE 1, GROUP IIA, TEMP. CLASS T3 HAZARDOUS AREA. TRANSMITTER SHALL ALSO
COMPLY WITH IECEx/ATEX/DIRECTIVE/94/9/EC REQUIREMENT AND BE CERTIFIED ACCORDINGLY.

9. ELECTRICAL SIGNAL CABLE ENTRY CONNECTION SHALL BE M20 x 1.5. VENDOR TO PROVIDE CERTIFIED ADAPTER IF REQUIRED.

10. THERMOWELL CONSTRUCTION SHALL COMPLY TO PTS STANDARD DRAWING D12.92.339-A.

11. VENDOR TO PROVIDE THE FOLLOWING CERTIFICATES/DOCUMENTS FOR PURCHASER'S REVIEW/APPROVAL :


i) CALIBRATION CERTIFICATE
ii) IECEX CERTIFICATE
iii) MATERIAL CERTIFICATE
- TYPE 3.1 FOR PRESSURE RETAINING PARTS NON SOUR SERVICE
- TYPE 3.2 FOR PRESSURE RETAINING PARTS SOUR SERVICE
iv) MANUAL
v) RECOMMENDED SPARE PARTS AND SPECIAL TOOLS
vi) 2 YEARS SPARE PART LIST

PROJECT TITLE : PROVISION OF ENGINEERING DESIGN SERVICES


FOR MURPHY'S OPERATIONS

WORK ORDER TITLE : PROVISION OF ENGINEERING WORKS FOR GOPB


BOOSTER COMPRESSOR (FEED)

WORK ORDER NUMBER :


WO-025B

F1 19-06-2020 Re-Approved For Bid NFT MJ ABS


ABS
MMCOG PROJECT NUMBER : MSO-A-0088 F0 - Not Used NFT MJ ABS
FA 15-06-2020 Issued For Review NFT MJ ABS
PREPARED CHECKED APPROVED APPROVED
MURPHY/S18039 REV DATE REVISION DESCRIPTION
CONTRACT NO. : MMC MMC MMC PTTEP
MMC Oil & Gas Engineering Sdn Bhd (125442-W) Sheet No 15 cont'd on sheet No. -
Eng. By :
Datasheet No.
MY-SK309-66-IC-DS-0010
Client :
PTTEP HK Offshore Limited (0995613W )
PTTEP Sarawak Oil Limited (993918-P) Specification No.
MY-SK309-66-ME-SP-0001
PTTEP Sabah Oil Limited (993919-M

You might also like