Cantilever FTNG Design

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

DESIGN OF MAT FOUNDATION

Mat Foundation Design(ACI 318-11) - Metric


Job Details

Job Name : F1.2


Included
X (m) Y (m) Z (m)
Support
55 0.00 -1.70 4.30

Load Details

Included Loads

Load Case No 111: 1.4DL

Load Type : Ultimate

Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -0.55 -252.39 -4.16 0.00 0.00 0.00

Load Case No 112: 1.2DL + 1.6LL + 0.5LR

Load Type : Ultimate

Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 0.28 -249.30 -4.39 0.00 0.00 0.00

Load Case No 113: 1.2DL + 1.6LR + 0.5LL

Load Type : Ultimate

Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -0.31 -240.63 -4.22 0.00 0.00 0.00

Load Case No 114: 1.2DL + 1.6LR + 0.5WL X-DIR

Load Type : Ultimate

Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00


Column Reactions Applied as Loads on the Mat
Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -0.56 -231.85 -4.01 0.00 0.00 0.00

Load Case No 115: 1.2DL + 1.6LR + 0.5WL X-DIR_R

Load Type : Ultimate

Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -0.56 -231.85 -4.01 0.00 0.00 0.00

Load Case No 116: 1.2DL + 1.6LR + 0.5WL Z-DIR

Load Type : Ultimate

Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -0.56 -231.85 -4.01 0.00 0.00 0.00

Load Case No 117: 1.2DL + 1.6LR + 0.5WL Z-DIR_R

Load Type : Ultimate

Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -0.56 -231.85 -4.01 0.00 0.00 0.00

Load Case No 118: 0.9DL + 1.0WL X-DIR

Load Type : Ultimate

Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -0.36 -162.25 -2.67 0.00 0.00 0.00

Load Case No 119: 0.9DL + 1.0WL X-DIR_R

Load Type : Ultimate


Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -0.36 -162.25 -2.67 0.00 0.00 0.00

Load Case No 120: 0.9DL + 1.6WL Z-DIR

Load Type : Ultimate

Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -0.36 -162.25 -2.67 0.00 0.00 0.00

Load Case No 121: 0.9DL + 1.6WL Z-DIR_R

Load Type : Ultimate

Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -0.36 -162.25 -2.67 0.00 0.00 0.00

Load Case No 122: 1.2DL + 1.0E X-DIR

Load Type : Ultimate

Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 15.10 -176.23 -3.95 0.00 0.00 0.00

Load Case No 123: 1.2DL + 1.0E X-DIR_R

Load Type : Ultimate

Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -16.05 -256.44 -3.18 0.00 0.00 0.00
Load Case No 124: 1.2DL + 1.0E Z-DIR

Load Type : Ultimate

Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 2.17 -212.55 16.08 0.00 0.00 0.00

Load Case No 125: 1.2DL + 1.0E Z-DIR_R

Load Type : Ultimate

Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -3.12 -220.11 -23.21 0.00 0.00 0.00

Load Case No 126: 0.9DL + 1.0E X-DIR

Load Type : Ultimate

Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 15.21 -122.14 -3.06 0.00 0.00 0.00

Load Case No 127: 0.9DL + 1.0E X-DIR_R

Load Type : Ultimate

Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -15.93 -202.35 -2.29 0.00 0.00 0.00

Load Case No 128: 0.9DL + 1.0E Z-DIR

Load Type : Ultimate

Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00


Column Reactions Applied as Loads on the Mat
Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 2.29 -158.47 16.97 0.00 0.00 0.00

Load Case No 129: 0.9DL + 1.0E Z-DIR_R

Load Type : Ultimate

Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -3.00 -166.03 -22.32 0.00 0.00 0.00

Load Case No 130: 1.2DL + 0.5LL + 1.0E X-DIR

Load Type : Ultimate

Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 15.34 -185.02 -4.16 0.00 0.00 0.00

Load Case No 131: 1.2DL + 0.5LL + 1.0E X-DIR_R

Load Type : Ultimate

Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -15.80 -265.22 -3.40 0.00 0.00 0.00

Load Case No 132: 1.2DL + 0.5LL + 1.0E Z-DIR

Load Type : Ultimate

Serviceability Factor : 0.00

Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 2.41 -221.34 15.87 0.00 0.00 0.00

Load Case No 133: 1.2DL + 0.5LL + 1.0E Z-DIR_R

Load Type : Ultimate

Serviceability Factor : 0.00


Design Factor : 1.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -2.87 -228.90 -23.43 0.00 0.00 0.00

Load Case No 201: 1.0DL

Load Type : Service

Serviceability Factor : 1.00

Design Factor : 0.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -0.40 -180.28 -2.97 0.00 0.00 0.00

Load Case No 202: 1.0DL + 1.0LL

Load Type : Service

Serviceability Factor : 1.00

Design Factor : 0.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 0.09 -197.85 -3.40 0.00 0.00 0.00

Load Case No 203: 1.0DL + 1.0LR

Load Type : Service

Serviceability Factor : 1.00

Design Factor : 0.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -0.45 -189.97 -3.25 0.00 0.00 0.00

Load Case No 204: 1.0DL + 0.75LL

Load Type : Service

Serviceability Factor : 1.00

Design Factor : 0.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -0.03 -193.46 -3.29 0.00 0.00 0.00
Load Case No 205: 1.0DL + 0.6WL X-DIR

Load Type : Service

Serviceability Factor : 1.00

Design Factor : 0.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -0.40 -180.28 -2.97 0.00 0.00 0.00

Load Case No 206: 1.0DL + 0.6WL X-DIR_R

Load Type : Service

Serviceability Factor : 1.00

Design Factor : 0.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -0.40 -180.28 -2.97 0.00 0.00 0.00

Load Case No 207: 1.0DL + 0.6WL Z-DIR

Load Type : Service

Serviceability Factor : 1.00

Design Factor : 0.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -0.40 -180.28 -2.97 0.00 0.00 0.00

Load Case No 208: 1.0DL + 0.6WL Z-DIR_R

Load Type : Service

Serviceability Factor : 1.00

Design Factor : 0.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -0.40 -180.28 -2.97 0.00 0.00 0.00

Load Case No 209: 1.0DL + 0.714E X-DIR

Load Type : Service

Serviceability Factor : 1.00

Design Factor : 0.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 10.72 -151.64 -3.24 0.00 0.00 0.00

Load Case No 210: 1.0DL + 0.714E X-DIR_R

Load Type : Service

Serviceability Factor : 1.00

Design Factor : 0.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -11.51 -208.91 -2.70 0.00 0.00 0.00

Load Case No 211: 1.0DL + 0.714E Z-DIR

Load Type : Service

Serviceability Factor : 1.00

Design Factor : 0.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 1.49 -177.58 11.06 0.00 0.00 0.00

Load Case No 212: 1.0DL + 0.714E Z-DIR_R

Load Type : Service

Serviceability Factor : 1.00

Design Factor : 0.00

Self Weight Factor : 1.00

Column Reactions Applied as Loads on the Mat


Fx Fy Fz Mx My Mz
NODE NO.
(kN) (kN) (kN) (kNm) (kNm) (kNm)
55 -2.28 -182.97 -17.00 0.00 0.00 0.00

Properties Details

Region Thickness(m) Material


MAT 0.40 Concrete

Soil Details

Boundary Subgrade Modulus Soil Height Above Mat Soil Density Applied Load due to Soil
MAT 12000.00kN/m2/m 1.70m 18.00kN/m3 30.60kN/m^2

Mat Dimension

Boundary Name : MAT


Node No X Coor(m) Y Coor(m) Z Coor(m)
1 -0.10 -1.70 3.30
2 1.90 -1.70 3.30
3 1.90 -1.70 5.30
Node No X Coor(m) Y Coor(m) Z Coor(m)
4 -0.10 -1.70 5.30

Analysis Results

Node Displacement Summary Table


Rx Ry Rz
- Node Number Load Case Dx(mm) Dy(mm) Dz(mm)
(Rad) (Rad) (Rad)

Max Dx 1 111 0.00 -24.41 0.00 0.00 0.00 0.02


Max Dy 3 131 0.00 12.70 0.00 -0.00 0.00 0.02
Max Dz 1 111 0.00 -24.41 0.00 0.00 0.00 0.02
Max Rx 24 124 0.00 -20.05 0.00 0.00 0.00 0.01
Max Ry 1 111 0.00 -24.41 0.00 0.00 0.00 0.02
Max Rz 22 131 0.00 -26.43 0.00 -0.00 0.00 0.02
Min Dx 1 111 0.00 -24.41 0.00 0.00 0.00 0.02
Min Dy 22 131 0.00 -26.43 0.00 -0.00 0.00 0.02
Min Dz 1 111 0.00 -24.41 0.00 0.00 0.00 0.02
Min Rx 20 133 0.00 -21.69 0.00 -0.00 0.00 0.02
Min Ry 1 111 0.00 -24.41 0.00 0.00 0.00 0.02
Min Rz 3 126 0.00 0.43 0.00 -0.00 0.00 0.01

Plate Stress Summary Table


SQx SQy Sx Sy Sxy Mx My Mxy
- Plate Load Case
(kN/m2 ) (kN/m2) (kN/m2) (kN/m2) (kN/m2) (kN-m/m) (kN-m/m) (kN-m/m)

Max SQX 24 131 138.06 -18.36 0.00 0.00 0.00 -12.12 2.11 -6.16
Max SQY 3 131 -292.41 704.79 0.00 0.00 0.00 -24.56 54.85 21.32
Max SX 1 111 -8.40 79.43 0.00 0.00 0.00 -3.34 1.09 5.91
Max SY 1 111 -8.40 79.43 0.00 0.00 0.00 -3.34 1.09 5.91
Max SXY 1 111 -8.40 79.43 0.00 0.00 0.00 -3.34 1.09 5.91
Max MX 36 133 23.35 -12.26 0.00 0.00 0.00 -0.57 1.17 -1.10
Max MY 3 131 -292.41 704.79 0.00 0.00 0.00 -24.56 54.85 21.32
Max MXY 3 131 -292.41 704.79 0.00 0.00 0.00 -24.56 54.85 21.32
Min SQX 3 111 -300.83 659.24 0.00 0.00 0.00 -18.35 52.29 16.79
Min SQY 4 131 -282.87 -691.72 0.00 0.00 0.00 -24.95 52.32 -22.40
Min SX 1 111 -8.40 79.43 0.00 0.00 0.00 -3.34 1.09 5.91
Min SY 1 111 -8.40 79.43 0.00 0.00 0.00 -3.34 1.09 5.91
Min SXY 1 111 -8.40 79.43 0.00 0.00 0.00 -3.34 1.09 5.91
Min MX 10 131 -179.48 -88.14 0.00 0.00 0.00 -28.13 36.55 -10.48
Min MY 6 129 -8.60 -46.58 0.00 0.00 0.00 -2.71 0.16 -4.04
Min MXY 4 131 -282.87 -691.72 0.00 0.00 0.00 -24.95 52.32 -22.40

Base Pressure Summary for Service Load conditions


Base Pressure
- Node X-Coor(m) Y-Coor(m) Z-Coor(m) Load Case
(kN/m2)
Maximum Base
22 -0.10 -1.70 4.30 210 249.31
Pressure
Minimum Base
2 1.90 -1.70 3.30 201 0.00
Pressure

Contact Area
Load Case Area in Contact(m2) % of Total Area Area out of Contact(m2) % of Total Area
111 3.00 75.00 1.00 25.00
112 3.00 75.00 1.00 25.00
113 3.00 75.00 1.00 25.00
114 3.00 75.00 1.00 25.00
115 3.00 75.00 1.00 25.00
116 3.00 75.00 1.00 25.00
117 3.00 75.00 1.00 25.00
118 3.67 91.67 0.33 8.33
119 3.67 91.67 0.33 8.33
120 3.67 91.67 0.33 8.33
121 3.67 91.67 0.33 8.33
122 3.67 91.67 0.33 8.33
123 3.00 75.00 1.00 25.00
124 3.00 75.00 1.00 25.00
125 3.00 75.00 1.00 25.00
126 3.67 91.67 0.33 8.33
127 3.00 75.00 1.00 25.00
128 3.67 91.67 0.33 8.33
129 3.39 84.72 0.61 15.28
130 3.61 90.28 0.39 9.72
131 3.00 75.00 1.00 25.00
132 3.00 75.00 1.00 25.00
133 3.00 75.00 1.00 25.00
201 3.00 75.00 1.00 25.00
202 3.00 75.00 1.00 25.00
203 3.00 75.00 1.00 25.00
204 3.00 75.00 1.00 25.00
205 3.00 75.00 1.00 25.00
206 3.00 75.00 1.00 25.00
207 3.00 75.00 1.00 25.00
208 3.00 75.00 1.00 25.00
209 3.67 91.67 0.33 8.33
210 3.00 75.00 1.00 25.00
211 3.17 79.17 0.83 20.83
212 3.00 75.00 1.00 25.00

Sliding Check
Sliding Force, Fx Sliding Force, Fz Resisting Force FOS(x) FOS(z)
Load Case No
(kN) (kN) (kN) (Along X Direction) (Along Z Direction)
201 -0.40 -2.97 136.43 344 45
202 0.09 -3.40 143.46 1550 42
203 -0.45 -3.25 140.31 314 43
204 -0.03 -3.29 141.70 4777 43
205 -0.40 -2.97 136.43 344 45
206 -0.40 -2.97 136.43 344 45
207 -0.40 -2.97 136.43 344 45
208 -0.40 -2.97 136.43 344 45
209 10.72 -3.24 124.97 11 38
210 -11.51 -2.70 147.88 12 54
211 1.49 11.06 135.35 90 12
212 -2.28 -17.00 137.51 60 8

Overturning Check
Distance to Distance to
Critical Critical Overturning Overturning Resisting Resisting FOS(x) FOS(z)
Load Case
Location Location Moment, Mx Moment, Mz Moment, Rx Moment, Rz (About X (About Z
No
Along X Along Z (kNm) (kNm) (kNm) (kNm) Direction) Direction)
(m) (m)
201 -0.10 0.00 -1.19 0.16 691.40 -160.79 581 1014
202 1.90 0.00 -1.36 -0.04 691.40 160.79 508 4345
203 -0.10 0.00 -1.30 0.18 691.40 -160.79 532 901
204 -0.10 0.00 -1.32 0.01 691.40 -160.79 524 13551
205 -0.10 0.00 -1.19 0.16 691.40 -160.79 581 1014
Distance to Distance to
Critical Critical Overturning Overturning Resisting Resisting FOS(x) FOS(z)
Load Case
Location Location Moment, Mx Moment, Mz Moment, Rx Moment, Rz (About X (About Z
No
Along X Along Z (kNm) (kNm) (kNm) (kNm) Direction) Direction)
(m) (m)
206 -0.10 0.00 -1.19 0.16 691.40 -160.79 581 1014
207 -0.10 0.00 -1.19 0.16 691.40 -160.79 581 1014
208 -0.10 0.00 -1.19 0.16 691.40 -160.79 581 1014
209 1.90 0.00 -1.30 -4.29 691.40 160.79 533 37
210 -0.10 0.00 -1.08 4.61 691.40 -160.79 640 34
211 1.90 5.30 4.42 -0.60 -160.79 160.79 36 269
212 -0.10 0.00 -6.80 0.91 691.40 -160.79 101 176

Mat Self Weight = 38.40 kN

Centre of Gravity of Mat (From Origin) = {0.90, -1.70, 4.30} m

Punching Shear Check

Column No. Load Case Service Stress (kN/m) Corner 1 (kN/m) Corner 2 (kN/m) Corner 3 (kN/m) Corner 4 (kN/m) Design Status
55 131 1141.54 -665.95 -665.95 -665.95 -665.95 Pass

Design Parameters

Min Max
Top Bottom Pedestal Pedestal Min Max Wood and
Panel f 'c Pedestal Bar Bar
fy (kN/m2) Cover Cover Min Bar Max Bar Spacing Spacing Armer
Name (kN/m2) Cover(m) Size Size
(m) (m) Size (mm) Size (mm) (mm) (mm) Moment
(mm) (mm)
MAT 414000.07 21000.00 0.05 0.07 0.05 16 20 12 60 100.00 300.00 Used

Design Output

Top of Mat Longitudinal Direction

Zone = 3

Governing Moment (MGOV) = 77.41 (kN-m/m)

For f 'C <4.0

Minimum % of Steel Required

= 0.0018

= 0.02

Effective Depth (d) = 0.34 (m)

Steel Percentage Required


= 0.0018

Where = 23.19

= 224.14 (kN/m^2)

Provided Area of Steel = 1.12 (in2)

As , Hence is acceptable

Reinforcement Details

Bar No = 16

Maximum Spacing(Smax)(User Specified) = 300.00 (mm)

Minimum Spacing(Smin)(User Specified) = 100.00 (mm)


Actual Spacing (S) = 260 (mm)

Smin<= S <= Smax

---------------------------------------

Top of Mat Transverse Direction

Zone = 3

Governing Moment (MGOV) = 42.89 (kN-m/m)

For f 'C <4.0

Minimum % of Steel Required

= 0.0018

= 0.02

Effective Depth (d) = 0.33 (m)

Steel Percentage Required


= 0.0018

Where = 23.19

= 136.69 (kN/m^2)

As , Hence is acceptable

Reinforcement Details

Bar No = 16

Maximum Spacing(Smax)(User Specified) = 300.00 (mm)

Minimum Spacing(Smin)(User Specified) = 100.00 (mm)

Actual Spacing (S) = 260 (mm)

Smin<= S <= Smax

---------------------------------------

Bottom of Mat Longitudinal Direction

Zone = 3

Governing Moment (MGOV) = -32.18 (kN-m/m)

For f 'C <4.0

Minimum % of Steel Required

= 0.0018

= 0.02

Effective Depth (d) = 0.32 (m)

= 0.0018
Steel Percentage Required

Where = 23.19

= 108.44 (kN/m^2)

As , Hence is acceptable

Reinforcement Details

Bar No = 16

Maximum Spacing(Smax)(User Specified) = 300.00 (mm)

Minimum Spacing(Smin)(User Specified) = 100.00 (mm)

Actual Spacing (S) = 260 (mm)

Smin<= S <= Smax

---------------------------------------

Bottom of Mat Transverse Direction

Zone = 3

Governing Moment (MGOV) = -142.18 (kN-m/m)

For f 'C <4.0

Minimum % of Steel Required

= 0.0018

= 0.02

Effective Depth (d) = 0.30 (m)

Steel Percentage Required


= 0.0018

Where = 23.19

= 531.46 (kN/m^2)

As , Hence is acceptable

Reinforcement Details

Bar No = 16

Maximum Spacing(Smax)(User Specified) = 300.00 (mm)

Minimum Spacing(Smin)(User Specified) = 100.00 (mm)

Actual Spacing (S) = 140 (mm)

Smin<= S <= Smax

---------------------------------------

You might also like