Data sheets 3 2 1 8

MEDAPOXY PRIMER AC
Anti-corrosion primer epoxy

DESCRIPTION must be removed. Clean carefully and free from


dust.
MEDAPOXY PRIMER AC is a two-component epoxy - The metal surfaces should be scoured by
resin system consisting of: sandblasting, shotblasting or with an abrasive
- Component A: Resin disc.
- Component B: Hardener - MEDAPOXY PRIMER is applied in only one
layer.
USE
MIXING
- Anti-corrosion primer on all metal supports Complete all preparations before starting the mixing
sequence and prepare only the quantity of mix that
can be used during this time.
PROPERTIES It is very important to properly mix the two
components of MEDAPOXY PRIMER AC in order to
- Good adherence to the majority of steels and obtain a homogeneous mix and completely to empty
metals. the containers in order to respect the report/ratio of
- Good mechanical resistances the mixture.
- Good resistance to the current chemical agents: - Mix element A,
concentrated acids little, used water, salted - Pour component B (hardener) into component A
water, oils, fuels… (resin) taking care to respect the mixing ratio.
Do not mix by hand ; mix for 3 to 5 minutes with a
Jiffy mixer blade and an electric drill at very low
CHARACTERISTICS speed. Scrape the sides of the container several
times to ensure complete mixing. Be careful not to
ƒ Mixing Ratio: introduce any air bubbles while mixing.
Component A: 1,05 kg Component B: 300 g METHOD OF APPLICATION
ƒ Density of mix: ........................... 1.3 ± 0,05 Apply with a brush, broom, or roller.
ƒ Viscosity at 25°C :......................... 35’’ to CF6
ƒ Pot life of mix: ........ 1 hour 30 min at 20 °C
PACKAGING AND STORAGE
ƒ Drying at 20 ° C and 65% H.R.
Out of touch ............................................ 3 h MEDAPOXY PRIMER is delivered in 13.5 kg multi-
ƒ Adherence on metal ............................ 3Mpa component pack:
ƒ Covering power .................... 350 to 400 g/m² Component A: 10 kg
Component B: 3.5 kg

Shelf life is one year in the original, unopened


DIRECTIONS FOR USE containers when stored in a dry environment at
temperatures of 5°C to 35ºC.
CONDITIONS OF USE
- Do not to apply when temperature is below 10°C
or above 30°C.
- Relative humidity must be lower than 80%.

SURFACE PREPARATION
- Surfaces receiving MEDAPOXY PRIMER AC
must be dry, clean and free from nonadherent
parts. All oil, grease, paintings or other stains

The information given in this data sheet is based on our knowledge and our experiment to date. They are given for indication.
It belongs to the customer to ensure that this product suits to the intended usage.

Granitex
Zone industrielle Oued Smar – BP85 Oued Smar – 16270 Alger
Tél : (213) 021 51 66 81 & 82
Fax : (213) 021 51 64 22 & 021 51 65 23
www.granitex.dz - E-mail: granitex@granitex.dz
Data sheets 3 2 1 8

MEDAPOXY PRIMER AC

PRECAUTIONS IDENTIFICATION:
Classification according to standard AFNOR NF T
Epoxydic resins can irritate the skin and the mucous
36.005: Family: 1 - Classify: 6b.
membranes. Consequently, it is advised to wear
rubber gloves during the use.
In case of skin or eye contact flush with plenty of REFERENCE DOCUMENTS:
water and take medical advice.. For the reception of the supports, their preparation
and the conditions for application, the applicator
After use clean the tools using an epoxy solvent must refer to standard NF P 74-203/DTU 59-3. ISO
(MEDILUPOX). 8-501 -1 and ISO 4-287-1

The information given in this data sheet is based on our knowledge and our experiment to date. They are given for indication.
It belongs to the customer to ensure that this product suits to the intended usage.

Granitex
Zone industrielle Oued Smar – BP85 Oued Smar – 16270 Alger
Tél : (213) 021 51 66 81 & 82
Fax : (213) 021 51 64 22 & 021 51 65 23
www.granitex.dz - E-mail: granitex@granitex.dz

You might also like