Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 10

BUREAU VERITAS VIETNAM

REMOTE VISUAL INSPECTION


NSRP PROCEDURE DOCUMENT No.:
DCSM PROJECT 2019 D-P5-BV-PD-012

Contractor’s Name : BUREAU VERITAS VIETNAM

Company’s Name : Nghi Son Refinery and Petrochemical LLC.


Plant Location : Nghi Son, Viet Nam

W/ Order No. :
Package No. : 5

Scope of Work : INSPECTION SERVICE FOR DCSM


Discipline : DCSM

NSRP DCSM PROJECT 2019


Discipline
Receiving Date
Reviewed By
Review Date
Review Result code
Document Review codes:
1- Rejected (Revise and resubmit), 2- Comments as Noted (Revise and
resubmit. Work may proceed subject to full compliance with comments),
3- Minor Comments (Acceptable, Works may proceed. Revise &
Resubmit as “Certified Final), 4- No comments (Works may Proceed)
Returned on
Next Submission Due
Date

THIS DOCUMENT IS CONTROLLED BY THE BUREAU VERITAS - VIETNAM AND MAY NOT BE AMENDED, REVISED OR ALTERED IN
ANY OTHER WAY WITHOUT THE CONSENT OF THAT COMPANY.

THE SIGNATURES BELOW AUTHORISE ALL PAGES OF THIS PROCEDURE FOR USE FROM THE DATE OF APPROVAL AS SHOWN.

Rev Date Description Prepared By Reviewed by Approved By


.
0 26/09/2019

Page 1 of 10
BUREAU VERITAS VIETNAM
REMOTE VISUAL INSPECTION
NSRP PROCEDURE DOCUMENT No.:
DCSM PROJECT 2019 D-P5-BV-PD-012

Nguyen Gia Dinh Annamalai Natarajan Annamalai Natarajan

REVISION HISTORY

Rev. Date Issued Comments Prepared by Reviewed & Approved by

00 26.Sep.2019 First Issue. Nguyen Gia Dinh Annamalai Natarajan

Page 2 of 10
BUREAU VERITAS VIETNAM
REMOTE VISUAL INSPECTION
NSRP PROCEDURE DOCUMENT No.:
DCSM PROJECT 2019 D-P5-BV-PD-012

INDEX

Section Description Page

1.0 Scope 4

2.0 Reference documents 4

3.0 Personnel Qualification 4

4.0 Safety 4

5.0 Client responsibility 5

6.0 Measuring Equipment 5

7.0 Inspection Practice 6

8.0 Acceptance Criteria 7

9.0 Records 7

Attachment 1 Report Format 9

Page 3 of 10
BUREAU VERITAS VIETNAM
REMOTE VISUAL INSPECTION
NSRP PROCEDURE DOCUMENT No.:
DCSM PROJECT 2019 D-P5-BV-PD-012

1.0 SCOPE:

1.1 This procedure describes the requirements for borescope examination of internal
condition pipe using Olympus IFLEX FX IV 8435 and IV 86180 and other equipment.

2.0 REFFERENCE DOCUMENTS:

1 ASME Sec V ASME Code for Non Destructive testing.

2 ASNT-SNT-TC-1A Guide lines for Personnel Qualification & Certification.

3.0 PERSONNEL QUALIFICATION:

3.1 Nondestructive testing personnel shall be certified with NDT VT-Level I or II minimum in
accordance with Company Written Practice for Qualification and Certification for NDT
Personnel as per SNT-TC-1A, or a similar document.

3.2 The results will be analyzed by person who is undergone the VT-Level-II Certified with
enough experience.

4.0 SAFETY:

4.1 All personnel are responsible for ensuring that they, as well as their fellow employees
perform their job in a safe and professional manner.

4.2 In addition they will also adhere to any statutory and local safety requirements along with
any Client / Project specific safety requirements.

4.3 All HSE requirements shall be strictly followed.

Page 4 of 10
BUREAU VERITAS VIETNAM
REMOTE VISUAL INSPECTION
NSRP PROCEDURE DOCUMENT No.:
DCSM PROJECT 2019 D-P5-BV-PD-012

5.0 CLIENT RESPONSIBILTY:

The following are the requirements to be executed before commencing the job:

5.1 The Client is to provide the job details such as drawing, numbering or identification
system, prior to the start of inspection.

5.2 Providing access flexible work place to the Inspector.

5.3 The inside surface has to be free from dirt, grease and loose particles and should be
suitable for Visual inspection.

6.0 MEASURING EQUIPMENT:

Sr. No Description IPEX FX IV8435 IPEX FX IV86180

1 Scope Outside Diameter 4.0mm 6.0mm

2 Insertion tube length 3.5m 18m

3 Angulation direction Up-down, Right, Left Up-down, Right, Left

4 Angulation Range 130° 50°

5 Optical Adaptor - Field of view 120° 50°

6 Optical Adaptor - Direction of view Forward Forward

7 Optical Adaptor - Depth of field 4 to 190 mm 5 to ∞ mm

High durability High durability


8 Insertion Tube Exterior
tungsten braid tungsten braid
Drop-, water- and Drop-, water- and
9 Harsh environment resistance dust-proof (complies dust-proof (complies
IP55) IP55)

Page 5 of 10
BUREAU VERITAS VIETNAM
REMOTE VISUAL INSPECTION
NSRP PROCEDURE DOCUMENT No.:
DCSM PROJECT 2019 D-P5-BV-PD-012

10 Light Source LED LED

100-240 V, 50/60
11 Power Supply - AC 100-240 V, 50/60 Hz
Hz

12 Power Supply - DC 14.8 V 14.8 V

13 Exposure control Yes Yes

250 (W) X 160 (D) X 250 (W) X 160 (D) X


14 Dimensions (Base Unit)
285 (H) mm 285 (H) mm
311 (W) X 92 (D) X 311 (W) X 92 (D) X
15 Dimensions (Control Unit)
192 (H) mm 192 (H) mm

16 Weight 6.6 kg with battery 6.6 kg with battery

17 Digital zoom Yes Yes

18 Thumbnail display Yes Yes

19 Still image recording file format JPEG/ TIFF JPEG/ TIFF

20 Movie recording file format AVI M-JPEG AVI M-JPEG

21 USB terminal USB version 1.1 USB version 1.1

22 Internal Memory 1 GB 1 GB

23 Stereo measurement (Depth) Yes Yes

24 Stereo measurement (Area) – 3D Yes Yes

7.0 INSEPCTION PROCEDURE:

7.1 Preparation:

7.1.1 In order to conduct a thorough inspection and reference information must be


accessed and studied before proceeding to conduct inspection.

Page 6 of 10
BUREAU VERITAS VIETNAM
REMOTE VISUAL INSPECTION
NSRP PROCEDURE DOCUMENT No.:
DCSM PROJECT 2019 D-P5-BV-PD-012

7.1.2 Check condition borescope unit and supporting equipment, Optical Tip, battery
and other.

7.1.3 Ensure that personal safety equipment and workplace conditions meet safety
criteria in accordance with applicable regulations.

7.2 Inspection:

7.2.1 Create a file name in accordance with the equipment to be inspected to facilitate
the creation of report

7.2.2 Insert the Camera Tip into the equipment that needs to be inspected.

7.2.3 Record the condition of inside equipment in the form of video or image as
requested by client.

7.2.4 If any finding the condition to be measured..

7.2.5 Do camera calibrations before use to measure the indication.

7.2.6 Measure the size of the indication and record.

7.2.7 All the inspection result are copied to the flash disk and transferred to the
computer.

7.2.8 Analyze and Reporting.

8.0 ACCEPTANCE CRITERIA:

8.1 The acceptance standards for the interpretation of items inspected shall be based on
Client requirements or the Contract Document.

9.0 RECORDS:

9.1 When required by the client, a written report shall be prepared for every borescope

Page 7 of 10
BUREAU VERITAS VIETNAM
REMOTE VISUAL INSPECTION
NSRP PROCEDURE DOCUMENT No.:
DCSM PROJECT 2019 D-P5-BV-PD-012

inspection carried out in accordance with this procedure.

9.2 The report shall contain, but not limited to the following information:

9.2.1 Date of inspection

9.2.2 Name of the fabricator or manufacturer

9.2.3 Material specification

9.2.4 Acceptance criteria

9.2.5 Material Identification, joint no. and repair status

9.2.6 Internal Condition Equipment

9.2.7 Attachment photo or Video

9.2.8 Inspection devices used

9.2.9 Comments and recommendations with reference to the acceptance criteria.

9.2.10 Name and signature of inspector

9.2.11 When a permanent visual record of imperfection and are required, a photograph
or on-scale accurate sketches shall be made indicating exact dimensions.

Page 8 of 10
BUREAU VERITAS VIETNAM
REMOTE VISUAL INSPECTION
NSRP PROCEDURE DOCUMENT No.:
DCSM PROJECT 2019 D-P5-BV-PD-012

ATTACHMENT 1

REPORT FORMAT

Page 9 of 10
BUREAU VERITAS VIETNAM
REMOTE VISUAL INSPECTION
NSRP PROCEDURE DOCUMENT No.:
DCSM PROJECT 2019 D-P5-BV-PD-012

Page 10 of 10