NSRP SDM2019 EXCHANGER SCHEDULE

Date: 02-10-2019
29-Oct 30-Oct 31-Oct 01-Nov 02-Nov 03-Nov 04-Nov 05-Nov 06-Nov 07-Nov 08-Nov 09-Nov 10-Nov 11-Nov 12-Nov 13-Nov 14-Nov 15-Nov 16-Nov 17-Nov 18-Nov 19-Nov 20-Nov 21-Nov 22-Nov 23-Nov
Secti
S/No. Unit Tag No. Type Tue Wed Thu Fri Sat Sun Mon Tue Wed Thu Fri Sat Sun Mon Tue Wed Thu Fri Sat Sun Mon Tue Wed Thu Fri Sat
on
Day1 Day2 Day3 Day4 Day5 Day6 Day7 Day8 Day9 Day10 Day11 Day12 Day13 Day14 Day15 Day16 Day17 Day18 Day19 Day20 Day21 Day22 Day23 Day24 Day25 Day26
Post Insert Close TB Out &
TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

1 1 10 010-E-001A U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

2 1 10 010-E-011A U Tube

Remove Post Install TB Out &


TB In & Unbolt Cover Open Plugs Pre-inspect Hydro-jet cleaning inspect TUBE (RT-20 FILMS ) Install Plugs Hydro Test Cover Reinstate

3 1 10 010-AC-006H AFC

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect ECT No Activity Bundle Test 1 Cover Test 2 Reinstate

4 1 11 011-K-001-E02 U Tube

Remove Post Install TB Out &


TB In & Unbolt Cover Open Plugs Pre-inspect Hydro-jet cleaning inspect MFL 100% Install Plugs Hydro Test Cover Reinstate

5 1 11 011-AC-003A AFC

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

6 1 13 013-E-201A U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

7 1 13 013-E-201B U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

8 1 13 013-E-201C U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

9 1 13 013-E-201D U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

10 1 13 013-E-201E U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

11 1 13 013-E-201F U Tube

Remove Post Install TB Out &


TB In & Unbolt Cover Open Plugs Pre-inspect Hydro-jet cleaning inspect IRIS 100% (225 Tubes) No Activity Install Plugs Hydro Test Cover Reinstate

12 1 13 013-AC-201 AFC

Remove Post Install TB Out &


TB In & Unbolt Cover Open Plugs Pre-inspect Hydro-jet cleaning inspect IRIS 100% (288 Tubes) No Activity Install Plugs Hydro Test Cover Reinstate

13 1 13 013-AC-101 AFC

Remove Post Install TB Out &


TB In & Unbolt Cover Open Plugs Pre-inspect Hydro-jet cleaning inspect IRIS 100% (402 Tubes) No Activity Install Plugs Hydro Test Cover Reinstate

14 1 14 014-AC-101A1&H1 AFC

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect ECT No Activity Bundle Test 1 Cover Test 2 Reinstate

15 2 20 020-E-002 U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

16 2 20 020-E-102B U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

17 3 22 022-E-002 U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

18 3 22 022-E-003 U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

19 3 23 023-E-203 U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

20 3 23 023-E-012A U Tube

TB In & Post Insert Close TB Out &


Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

21 3 23 023-E-006 U Tube

TB In & Post Insert Close TB Out &


Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

22 3 23 023-E-302B U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

23 3 23 023-E-013 U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

24 3 23 023-E-651 U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

25 3 23 023-E-014 U Tube

TB In & Post Insert Close TB Out &


Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

26 3 23 023-E-012D U Tube
Cover
TB In & cleaning & Post Insert Close TB Out &
Unbolt Drop Cover Pull Bundle Pre-inspect Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

27 3 23 023-E-007 U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

28 3 23 023-E-011 U Tube

Remove Post Install Install TB Out &


TB In & Unbolt Cover Open Plugs Pre-inspect Hydro-jet cleaning inspect MFL 100% Plugs Hydro Test Cover Reinstate

29 3 23 023-AC-201 AFC

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

30 3 28 028-E-002 U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

31 3 28 028-E-202 U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

32 3 28 028-E-302 U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

33 3 28 028-E-203 U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

34 3 28 028-E-402 U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

35 3 28 028-E-502 U Tube
NSRP SDM2019 EXCHANGER SCHEDULE
Date: 02-10-2019
29-Oct 30-Oct 31-Oct 01-Nov 02-Nov 03-Nov 04-Nov 05-Nov 06-Nov 07-Nov 08-Nov 09-Nov 10-Nov 11-Nov 12-Nov 13-Nov 14-Nov 15-Nov 16-Nov 17-Nov 18-Nov 19-Nov 20-Nov 21-Nov 22-Nov 23-Nov
Secti
S/No. Unit Tag No. Type Tue Wed Thu Fri Sat Sun Mon Tue Wed Thu Fri Sat Sun Mon Tue Wed Thu Fri Sat Sun Mon Tue Wed Thu Fri Sat
on
Day1 Day2 Day3 Day4 Day5 Day6 Day7 Day8 Day9 Day10 Day11 Day12 Day13 Day14 Day15 Day16 Day17 Day18 Day19 Day20 Day21 Day22 Day23 Day24 Day25 Day26
Post Insert Close TB Out &
TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

36 1 40 040-E-201 U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

37 1 40 040-E-205 U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

38 1 40 040-E-202A U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

39 1 40 040-E-202B U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

40 1 40 040-E-204 U Tube

Remove Post Install TB Out &


TB In & Unbolt Cover Open Plugs Pre-inspect Hydro-jet cleaning inspect IRIS 100% (Bundle-A) No Activity Install Plugs Hydro Test Cover Reinstate

41 1 40 040-AC-101 AFC

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

42 1 43 043-E-102 U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

43 1 44 044-E-101 U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

44 1 48 048-E-301 U Tube

Remove Post Install Install TB Out &


TB In & Unbolt Drop Spool Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Test 1 Bundle Spool Reinstate

45 4 61 061-E-303 Reboiler

Open Post Install TB Out &


TB In & Unbolt Cover Pre-inspect Cover cleaning & Hydro-jet inspect Plates Test 1 Test 2 Reinstate

46 4 61 061-E-208A Plate Type

Post Close TB Out &


TB In & Unbolt Drop Cover Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Test 1 Cover Test 2 Reinstate

47 2 70 070-E-104 Fixed Tube

Remove Post Install TB Out &


TB In & Unbolt Cover Open Plugs Pre-inspect Hydro-jet cleaning inspect MFL 100% 189 Tubes Install Plugs Hydro Test Cover Reinstate

48 2 80 080-AC-002 AFC

Remove Post Install TB Out &


TB In & Unbolt Cover Open Plugs Pre-inspect Hydro-jet cleaning inspect IRIS 100% (336 Tubes) Install Plugs Hydro Test Cover Reinstate

49 2 80 080-AC-001 AFC

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

50 3 81 081-E-0002B U Tube

Remove Post Install TB Out &


TB In & Unbolt Cover Open Plugs Pre-inspect Hydro-jet cleaning inspect TUBE RT 20 FILMS No Activity Install Plugs Hydro Test Cover Reinstate

51 3 81 081-AC-001 AFC

Remove Post Install TB Out &


TB In & Unbolt Cover Open Plugs Pre-inspect Hydro-jet cleaning inspect TUBE RT 20 FILMS No Activity Install Plugs Hydro Test Cover Reinstate

52 2 84 084-AC-002 AFC

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

53 2 92 092-E-005A U Tube

Post Insert Close TB Out &


TB In & Unbolt Drop Cover Pull Bundle Pre-inspect Cover cleaning & Hydro-jet inspect RFET No Activity Bundle Test 1 Cover Test 2 Reinstate

54 2 92 092-E-008A U Tube

Open Man Set Up Post Box Up TB Out &


TB Insert hole Ventilation Pre-inspect Dry cleaning (confined Space) inspect man hole Reinstate

55 2 93 093-E-030 Supeheater

Open Man Set Up Post Box Up TB Out &


TB Insert hole Ventilation Pre-inspect Dry cleaning (confined Space) inspect man hole Reinstate

56 2 93 093-E-130 Supeheater

You might also like