AFCONS - QUA - Inspection and Test Plan - Geotechnical Survey

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

ITP/5267/QC/01/00

INSPECTION AND TEST PLAN FOR GEOTECHNICAL SURVEY

Rev. No. / Date:


Project: EPC Contract for Permanent Anticipated Works between KP24 and KP105 of Transgabonaise National Road located in the Republic of Gabon

Contractor: AFCONS Infrastructure Limited

Employer: Société Autoroutière Du Gabon (SAG)

Consultant: Independent Control Officer (ICO)

Frequency of test
Sr. No. Material / Test Code Ref. Permissible Limits Performer AFCONS / IL ICO Records Remarks
(3.2)

1 Field Investigation:

Existing Platform Test Pits Soil


1.1 Employer's Requirements Part- NA AFCONS / IL 1 / 100m P W -
Sampling
III.02 Performance
Bearing Capacity Test on Specifications 3.2
1.2 NA AFCONS / IL 1 / 200m P W -
Existing Platform

2 Laboratory Test for Classification of the Soils:

2.1 Analysis Granulometric NF P94-056 NA AFCONS / IL 1 / Test Pit P W/A TR

2.2 Plasticity Index (%) NF P94-051 NA AFCONS / IL 1 / Test Pit P W/A TR

2.3 Proctor NF P94-093 NA AFCONS / IL 1 / Test Pit P W/A TR

2.4 Swelling (%) NF P94-078 NA AFCONS / IL 1 / Test Pit P W/A TR

CBR at 90%,
2.5 NF P94-078 NA AFCONS / IL 1 / Test Pit P W/A TR
4 days immersion

W: Witness of activity MTC: Manufacturer's test Certificate ASL: AFCONS Site Laboratory P: Perform

M: Monitor MTR: material Test Report IL: Independent Laboratory approved . H: Hold

R: Review A: Approved TR: Test Report

PREPARED BY REVIEWED BY APPROVED BY

AFCONS REPRESENTATIVE AFCONS REPRESENTATIVE ICO REPRESENTATIVE

You might also like