Question
What parameters are used to set up datalinks in a PowerFlex 70 or 700 AC Drive?
Environment
20A PowerFlex 70
20B PowerFlex 700
Answer
Parameters 300 [Data In A1] - Parameter 307 [Data In D2] are used for data that the drive is receiving from
the network.
Parameters 310 [Data Out A1] - Parameter 317 [Data Out D2] are used for data that the drive is sending to
the network.