PIPING DESIGN INSTRUCTION RDMP PROJECT

[PI-DI-014] UG PIPING 16.Jan.2020 (Rev.4)

<Reference>
- 26070-100-3DG-P24-J0001-B00 “Underground Piping System”
- 26070-100-3SS-P34D-J0002-B00 “PEDP Piping Design Criteria”
- 26070-203-3PS-U04-W0002 “Specification for fire protection”
- 26070-203-3BD-H04-J0002-B01 “Sewage and drainage design basis
environmental engineering”

A. PURPOSE
1. This document provides the UG piping concept and summary of the reference documents
to get the approval from the owner. After receiving the approval from the owner,
Underground piping shall be incorporated as per this specification.

B. FREEZE CONDITION
1. Frost line is not applicable for RDMP project.

C. UNDERGROUND PIPING LINE. <26070-100-3DG-P24-J0001_B00 / PARA. 2.2>

1. Non-Contaminated Storm Water Sewer System


2. Potentially Contaminated Storm Water Sewer System
3. Oily Water Sewer System
4. Closed Process Sewer System
5. Underground Firewater Network
6. Underground Cooling Water Supply/Return Network
7. Gravity Sanitary Sewer System
8. Underground Water Services (Potable, Utility, etc.)
9. Underground Utility Services (Air Services, nitrogen, etc.)
10. Underground Sanitary Sewer Force Main

D. CONSIDERATION FOR UG COMPOSITE DRAWING

1. Unit number, Fluid Service, Line no, Line Size, Material Class shall be indicated.

Ex) 067-D-010-4”-1CB2B41-N

2. Pipe Elevation - BOP Elevation, Working Point Elevation

Ex) WP BOP EL.-1067

3. Existing Underground Piping.

4. Crossing detail between pipes