Troubleshooting
Troubleshooting using error code
Teode Valid from serial number Date Order number
815, 816 6070557-
2009-12-22 7510399-040
The first digit of the three-digit error code indicates the severity of the
error and how the truck is affected/responds when the error occurs.
Code
number
Error category/action taken
n:0nn
Caution. Generally an information code, No action to
be taken on the truck.
nein
Warning. Some functions may be disabled or
reduced. See the specific error code to see what
action has been taken.
n:2nn
Error, All parts of the hydraulic system are disabled.
See the specific error code to see what action has
been taken.
n:3nn
Error. The truck is braked by the motor and/or the
support arm brake and/or the parking brake until it
‘comes to a halt. It is not possible to drive. The steer-
ing may be disabled if there is a steering error. To
see what action has been taken, see the specific
error code.
n:4nn
Error. The truck is braked by the motor brake until it
stops. Once the truck has stopped, or after 5 sec-
onds, the relays for the main power supply and key
are switched off
n:5nn
Critical error.
Main contactor and key relay opens.
The error codes are subdivided into smaller categories based on the
last two digits of the code (see below).
Error code, type of error
Code
number
:n00—n08
n:nt0—n19
Deseri
fion
Miscellaneous error codes.
CAN-related error codes.
n:n20-139
Error codes related to specific units.
n:n40—n59
Error codes for short-circuited output data.
n:n60—n79
Error codes for output data from open electrical
circuits.
n:n80—n99
Faulty signals from sensors.Troubleshooting
Troubleshooting using error code
Ordernumber Date Valid from serial number T-code
7510399-040 2009-12-22 6070557- 815,816
8.5.1 CID, warnings and errors
Indica- | Cause Tip
tor.
1,003 Slight firmware version incompati Update the truck software to the latest
ity. available version.
The firmware versions in the MCU and
CID do not match. The MCU does not
support some of the functions used by
the CID, or vice versa.
1.004 | Incompatibility in the display Update the truck software to the latest
firmware. available version,
The firmware versions in the MCU and
CID do not match, The MCU does not
‘support some of the functions used by
the CID, or vice versa.
1,010 CAN 1 communication warning. 1. Check that CAN 1 is intact in terms of
The CID CAN module has received too ate Se ia ciel
contacts.
many error messages
2. Disonnect the battery. Check that the
resistance between [X41:3] and
[X41:4] is 54 — 66 ohm.
3. Deactivate and disconnect LID and
DHU.
1.120 LID sends an invalid status. Update the truck firmware to the latest
The LID is blocked. available version.
7.121 | No message received from the LID. | 1. Check that CAN 1 is intact in terms of
LID blocked. wiring harness, final resistance and
contacts.
2. Disonnect the battery. Check that the
resistance between [X41:3] and
[X41:4] is 54 - 66 ohm.
3. Deactivate and disconnect LID.
4:412 LID communication warning. 1. Verify that CAN 1 is complete with re-
The LID is blocked,
gard to cabling, final resistor and ter-
minals
2. Disconnect the battery. Verify that the
resistor between [X41:3] and [X41:4]
provides 54— 66 ohms.
3. Disable by changing parameter 1106
and disconnecting the LIDTroubleshooting
Troubleshooting using error code
Teode Valid from serial number Date Order number
815, 816 6070857- 2009-12-22 7510399-040
Indica- | Cause Tip
tor.
7431] External +5 Vis ou 7. Disconnect the joysticks, buttons and
ted area. sensors connected to [X505:1] one at
a time and check ifthe error code dis-
appears.
2. Check the CID's internal wiring har-
ness.
3._ Replace the CID.
7500 | Software error Update the truck's software to the latest
available version
1501 | GlD has detected an error in the Update the truck's software to the latest
MCU's program execution. available version,
1.503 | Only one of the CID and the MCU is | 1. Log off and make the truck without
in emergency driving mode. voltage for approx 1 minute.
2. Restart the truck and log in again
1504 | The software for CID and MCU are _| 1. Update the software for CID, MCU and
not compatible. other units tothe latest available ver-
Not possible to log in. sions.
2. Check that the software are compati-
ble.
7:507 | GID and MGU firmware packages are | Update the truck software to the latest
incompatible. available version
The firmware versions in the MCU and
CID do not match. The MCU does not
support some of the functions used by
the CID, or vice versa.
7:508 | LID and MCU firmware packages are | Update the truck software to the latest
2 incompatible. available version,
1:508 | The firmware versions in the MCU and
LID do not match. The MCU does not
support some of the functions used by
the LID, or vice versa
1.510 | Communication error - GAN 1. 7. Check that CAN T is intact in terms of
wiring hamess, final resistance and
contacts
2. Disonnect the battery. Check that the
resistance between [X41:3] and
[X41:4] is 54-66 ohm,
3. Deactivate and disconnect LID, BHU
and collision sensor. Activate and then
connect them one by one to find out
which unit gives rise to the communi-
cation error.Order number
7510399-040
tor.
Indica-
Date
2009-12-22 6070557-
Cause
Valid from serial number
Troubleshooting
Troubleshooting using error code
Tcode
815, 816
Tip
1512
‘Communication disturbance — CAN
1.
7_ Check that CAN is intact in terms of
wiring harness, final resistance and
contacts.
2. Disonnect the battery. Check that the
resistance between [X41:3] and
[X41:4] is 54 —66 ohm
3, Deactivate and disconnect LID, DHU
and collision sensor. Activate and then
connect them one by one to find out
which unit gives rise to the communi-
cation error.
1.514
1.516
MCU or CID has not received a
response within 70 ms via CANT.
1, Check that CAN 1 is intact in terms of,
wiring harness, final resistance and
contacts.
2. Disonnect the battery. Check that the
resistance between [X41:3] and
[X41:4] is 54-66 ohm
3. Deactivate and disconnect LID, DHU
and collision sensor. Activate and then
‘connect them one by one to find out
which unit gives rise to the communi-
cation error,
1.520
Internal +5 Vis outside the permitted
area.
Replace the CID.
1.540
Key relay [K20] - Break in the control
circuits
1. Check that there is no break in the key
relay's coil
2, Check the contacts [X131] and [X504]
the relationship between [K20:A1] —
[X131:5] as well as [20:A2] —
[x504:17].
3. Replace the CID [A‘]
1.580
Key Relay [K20] — Contacts welded
1. Check the key relay’s function and that
there is no relationship between
[K20:1] and [20:2]
2. Check for the presence of a short
cuit that may cause improper feeding
of [X504:7], e.g. from [X504:16],
[X504:17] and [X504:18}Troubleshooting
Troubleshooting using error code
Teode Valid from serial number Date Order number
815, 816 6070587- 2009-12-22 7510398-040
Indica- | Cause Tip
tor.
7581 | Key relay [K20] does not close Check if the CID's input [X504:7] switches
status when the key relay is used, CID's
diagnostic screen 2, pos 20:
32] 1-8: ao1a9000
7 | 27462 Ooogo000
1?-24: 10@--
25-32
If the input does not change status:
+ Check that fuse [F74] is complete.
+ Check the key relay’s function and that
there is a relationship between [K20:1]
and [K20:2] when the relay is drawn.
+ Check that conductor 26 from the key
relay to the fuse box and conductor 28
from the fuse box to the CID input
[X504: 7] are intact.
+ Replace the CID.
If the input changes status:
+ Update the CID's software.
+ Replace the CID [A1].Troubleshooting
Troubleshooting using error code
Order number Date Valid from serial number T-eode
7510399-040 2009-12-22 6070557- 815,816
8.5.2 MCU and other warnings and errors
Indica- | Cause Tip
tor.
2,002 __| The MCU Is programmed using stand- | Download or adjust the parameters to cor-
ard values for parameters. respond with the truck model and equip-
ment.
2.003 | MCU memory error. 1. Backup the truck's parameters.
Backup data, hour meter and errorlog | > Yadate to the latest software.
may be affected
3. Check parameters and hour meter.
4. Copy the truck configuration from CID
to MCU.
2,004 | Error in check sums of backup data. | 1. IfMCU or CID has been changed,
Normally shown after replacing MCU or copy the truck configuration from the
CID. MCU or CID unit which has not been
replaced to the new unit
2. Backup the truck's parameters.
3. Update to the latest software.
4. Check parameters and hour meter.
2.005 | Hour meter reading to service=0. | Carry out service reset the S counter
using TruckCom.
2.006 _| Full error log buffer. Shows that errors which would normally
No indication, logged only. be logged in the error log may have been
lost.
2.007 | MCU internal memory full 1. Report the error to the manufacturer.
2. Restart the truck.
3. Ifthe error remains, update the truck
firmware to the latest available ver-
sion.
2:008 | Application time. Set when the application (20 ms) takes
No indication, logged only. longer than 17 ms.
1, Fix the error code generated in direct
relation with this error code.
2. Report the fault to the manufacturer.
2.009 | Tick time.
No indication, logged only.
Set when tick time (1.25 ms) takes longer
than 1.10 ms.
1. Fix the error code generated in direct
relation with this error code.
2. Report the fault to the manufacturer.Troubleshooting
Troubleshooting using error code
Teode
815, 816
Indica-
tor.
Valid from serial number
6070557-
Cause
Date
2009-12-22
Order number
7510399-040
Tip
2010
2.011
‘Communication disturbance - CAN 1
MCU has received too many incorrect
telegrams.
Communication disturbance - CAN2.
MCU has received too many incorrect
telegrams.
7. Ifthe CAN keyis connected: Try using
a CAN-Key with a later production
date.
2. Check that CAN 1 is intact in terms of
wiring hamess, final resistance and
contacts.
3. Disonnect the battery. Check that the
resistance between [X41:3] and
[X41:4] is 54-66 ohm.
4. Deactivate and disconnect LID, BHU
and collision sensor. Activate and then
connect them one by one to find out
which unit gives rise to the communi-
cation error.
1. Check that CAN 2 is intact in terms of
wiring hamess, final resistance and
contacts.
2. Disonnect the battery. Check that the
resistance between [X130:8] and
[X130:22] is $4 - 66 ohm.
3. Disconnect EPS, ACT and ACH. Then
connect them one by one to find out
which unit gives rise to the communi-
cation error.
2101
Truck type incorrect.
Factory parameters have not been
entered,
Use TruckCom to save the parameter val-
ues,
If the MCU was replaced:
+ Enter the truck's parameter list.
+ Check parameter "1001 - Truck type’, if
itis incorrect all parameters must be
verified
+ Copy the Truck Configuration from the
CID to the MCU
2:102
Height pre-selection — Stop hi
error.
1. Lifting: Inspect/adjust parameters
371, 373 and 375.
2. Lowering: Inspect the free-lowering
and main lowering valve calibration.
Inspect/adjust parameters 372, 374
and 376.
3. Adjust parameter 377Troubleshooting
Troubleshooting using error code
Order number Date Valid from serial number T-eode
7510399-040 2009-12-22 6070557- 815,816
Indica- | Cause Tip
tor.
2:103__| Lifting height limiting. Ifthe truck Is equipped with height indica
Lifting height limiting is activated and _| tion, activate this using factory parameter
height measurement is deactivated. 1009 = 1.
If the truck does not have height indica-
tion, deactivate the lifting height limiting
using parameter 1107 = 0.
2:104 | Height pre-selection Ifthe truck features height indication, ena-
Height pre-selection is enabled and ble this with factor parameter 1009 = 1
height measurement is disabled If the truck does not feature height indica-
tion, disable height pre-selection with
parameter 1103 = 0
2:105 | More than 80 % difference between | Check parameter 113.
the MCU's measured power con- B-version: 280
sumption and the measure consump- | E-version: 335
n of the ACTIACH (>2 sek @ >200
A).
No reduction/blocking of the truck's func-
tions.
2:106 | Collision locking. if parameter 112 = 0: Use the special PIN
Acolision value exceeding what has_| code to reset the collision sensor.
been input via parameters 110 and 111 | If parameter 112 = 1: Restart the truck to
has been detected, teset the collision sensor.
The truck can only be driven at reduced
speed.
2:141 | Digital output DO9 — short circuit 1. Check that conductor X131:9, conduc-
tor 33, has not short circuited with con-
ductor 27
2. Check that fan G3 has not short
circuited.
3. Check that cables and contacts are
undamaged
4, Check output DOS via the CID's diag-
nostic screen 5, pos 9:
£2] 4-8: oo1ocoo1
5] oe @poooacoTroubleshooting
Troubleshooting using error code
Teode Valid from serial number Date Order number
815,816 6070557- 2009-12-22 7510399-040
Indica- | Cause Tip
tor.
2:161 | Digital output DOS — break. 7. Check that there is no break in con-
ductor X131:9, conductor 33 and con-
ductor 27 leading to fan G3.
2. Check that cables and contacts are
undamaged
3. Check output DOS via the CID's diag-
nostic screen 5, pos 9:
| 1-8: oore002
5 | 26 @pooo000
25-32
23180 | No contact with the shock sensor. _| 1._ ifthe truckis not equipped with a coli
sion sensor, set parameter 110 = 0
and 111
2. Check that cables and contacts are
undamaged
3. Replace [B90]
2:401 _| Internal programme error 1. Report the error to the manufacturer.
Restart the truck
If the error remains, update the truck
firmware to the latest available ver-
sion.
2:403 | Permitted time for reading the ana- | 1. Report the error to the manufacturer.
logue 2. Restart the truck
signal exceeded.
3. Ifthe error remains, update the truck
firmware to the latest available ver-
sion.
2:420 | Battery voltage under 33.6 V. 1. Check the battery voltage.
2. Check that the battery cable is undam-
aged and free from oxidation.
3. Check that the voltage between
[130:19] and [X130:32] corresponds
to the measured battery voltage.
4. Replace the MCUOrder number
7510399-040
Indica-
tor.
Date
2009-12-22 6070557-
Cause
Valid from serial number
Troubleshooting
Troubleshooting using error code
Tcode
815, 816
Tip
2421
2:431
2:432
Battery voltage over 72 V.
+5 V for external sensors under +4.9
v.
+5 V for external sensors over +5.1 V.
7. Ifthe error code occurs in association
with strong motor braking directly after
charging: Log outilog in.
2. Ifthe error code occurs during motor
braking during normal driving:
Check all power cabling between the
battery and transistor regulator for
breaks, poorly tightened screws/nuts
and oxidation.
Ifthe error code is shown at the same time
as error code 2:433, the troubleshooting
must begin with this,
1. Make sure that no short circuit or other
high load is present in the sensor (B4],
safety pedal or pedal unit for speed
and braking.
2. Check the wiring hamess to the com-
ponents above.
3. Replace the MCU and check the func-
tion of the sensor [B4], safety pedal
and pedal unit for speed and braking.
1. Check that there is no short circuit
present in conductor 55 and any con-
ductor with higher voltage than 5 V,
eg. battery voltage,
2. Check the function of
= Sensor [B4]
~ Safety pedal
— Pedal unit for speed and brakes.
3._ Replace the MCU.
2:433
+15 V for external sensors under +12
v.
1. Check that there is no short circuit or
high load in sensors [B18] and [B19]
2. Check the wiring hamess to the com-
ponents above.
3. replace the MCU and check the func-
tion of sensors [B18] and [B19]Troubleshooting
Troubleshooting using error code
Teode Valid from serial number Date Order number
815, 816 6070587- 2009-12-22 7510399-040
Indica- | Cause Tip
tor.
2434] #15 V for external sensors over #165 | 1. Check hat there isno shor circu
v. present in conductor 29 and any con-
ductor with higher voltage than 15 V,
e.g. battery voltage.
2. Check the function of sensors [B18]
and [B19]
3. Replace the MCU.
2435 | Internal 47.5 V under 47 V. Replace the MCU.
2:436__ | Internal +7.5 V over #8 V. Replace the MCU
2:501 | Check sum error, parameters 7. Restart the truck
2._ Replace the MCU
2502 _| Serious firmware error, MCU. 7. Report the errorto the manufacturer,
2. Restart the truck,
3. Ifthe error remains, update the truck
firmware to the latest available ver-
sion,
2:503_| error in check sum, factory parame- | 1. If MCU or CID has been changed,
ters. copy the truck configuration from the
Normally shown after replacing MCU or | MCU or CID unit which has not been
cD. replaced to the new unit
2. Backup the truck's parameters.
3. Update to the latest software,
4, Check factory parameters.
2:504 | Only one of the CID and the MCU is in | 1. Log off and make the truck without
emergency driving mode. voltage for approx 1 minute.
2. Restart the truck and log in again
2:505 | MCU has detected an error inthe | Update the truck's software to the latest
CID's program execution. available version,
2507 | Truck operation disabled, Contact the local representative of the
manufacturer, or the manufacturer
Seo ele coker directly, to reactivate the truck,Order number
7510399-040
Indica-
tor.
Troubleshooting
Troubleshooting using error code
Date Valid from serial number T-code
2009-12-22 6070587- 815, 816
Cause Tip
2510
2511
2612
Initialisation error — CAN 1.
Initialisation error — CAN 2.
‘Communication disturbance — CAN 1.
1. Check that CAN 1 is intact in terms of
wiring hamess, final resistance and
contacts.
2. Disonnect the battery. Check that the
resistance between [X41:3] and
[X41:4] is 54-66 ohm
3, Deactivate, disconnect and reconnect
the units from CAN1 individually to find
the device giving rise to the initialisa
tion error.
1. Check that CAN 2is intact in terms of
wiring harness, final resistance and
contacts.
2. Disonnect the battery. Check that the
resistance between [X130:8] and
[X130:22] is 54 — 66 ohm.
3, Deactivate, disconnect and reconnect
the units from CAN2 individually to find
the device giving rise to the initialisa-
tion error.
1. Check that CAN 1 is intact in terms of
wiring hamess, final resistance and
contacts.
2. Disonnect the battery. Check that the
resistance between [X41:3] and
[X41:4] is 54-66 ohm
3, Deactivate and disconnect LID, DHU
and collision sensor. Activate and then
‘connect them one by one to find out
which unit gives rise to the communi-
cation error,
2513
‘Communication disturbance — CAN 2.
1. Check that CAN 2s intact in terms of
wiring hamess, final resistance and
contacts,
2. Disonnect the battery. Check that the
resistance between [X130:8] and
[X130:22] is 54 — 66 ohm,Troubleshooting
Troubleshooting using error code
Teode Valid from serial number Date Order number
815, 816 6070587- 2009-12-22 7510398-040
Indica- | Cause Tip
tor.
2514 | Login error — DHU. Check that parameter 503 corresponds to
the truck's equipment:
4. Check that itis possible to connect
TruckCom to the DHU.
Ifitis possible to connect them, check
the DHU's configuration,
2. Check that the DHU's green LED is lt.
If the LED is not lit: Check the DHU's
feed voltage: The battery voltage be-
tween [A82:1] and [A82:8]
If there is a battery voltage: Replace
the DHU.
3. Check that CAN 1 is intact in terms of
wiring hamess, final resistance and
contacts: Disonnect the battery. Check
that the resistance between [A82:2]
and [A82:3] is 54 - 66 ohm
2:523 | Discharge current over 800 A. Check parameter 113:
B-version: 280
E-version: 335
2:531__| Internal +5 V under +4.9 V. Replace the MCU.
2:532 _| Internal +5 V over +5.5 V. Replace the MCU.
2:533 _| Internal +15 V under +14.25 V. Replace the MCU.
2534 _| Internal +15 V over #15.75 V. Replace the MCU.
2:537 | Internal feed supply for digital outputs | Replace the MCU.
under 9.7 V.
2:538 | Internal feed supply for digital outputs | Replace the MCU.
over 12V.
2:540 | Short circuit in output for main con- | 7. Check that the main contactor's coil
tactor [Q10]. has not short circuited,
2. Check that there is no short circuit in
connection [X131:7], cable 31.
3. Replace the MCU and check the main
contactors function.
2:555 _| Valid time for startup exceeded. Check that fuse [F73] is complete.
2. Check that the wiring harness and
contacts are intact and correctly at-
tached.Troubleshooting
Troubleshooting using error code
Ordernumber Date Valid from serial number T-code
7510399-040 2009-12-22 6070557- 815,816
Indica- | Cause Tip
tor.
2556 | Valid T__Tum off the truck by disconnecting the
battery.
2. Restart the truck and log in.
2:560 | Main contactor [Q10] output inter- | 1. Verify that the main contactor coil is
rupted. not interrupted
2. Verify that there is no interruption be-
tween terminal [Q10:A2] and [X131:7],
cable 31
3. Verify that the battery voltage is
present between [Q10:A1] and B-.
If there is no battery voltage.
+ Check that the emergency switch is
not depressed,
+ Verify that the F60 fuse is not defec-
tive
4, Log in in the emergency travel mode
to reset the main contactor status.
5. Inspect the main contactor for correct
operation.
Replace the main contactor
7. Replace the MCU
2:580 | Main contactor [Q10] - Terminals 1. Inspect the main contactor for correct
welded operation and that there is no connec-
tion between [10:1] and [10:2]
2. Verify that there is no short-circuit that
could cause incorrect power supply to
(13135).
3. Loginin the emergency travel mode to
reset the main contactor status.
2:581 | Main contactor [10] — A 1. Inspect the fuse [F771]
detected by MCU. 2. Inspect the main contactor for correct
operation and that there is connection
between [Q10:1] and [Q10:2].
3. Verify that there is no interruption in
conductor 8 between the main contac-
tor and the fuse panel as well as in
conductor 23 between the fuse panel
and [X131:15}
4, Loginin the emergency travel mode to
reset the main contactor status.Troubleshooting
Troubleshooting using error code
Teode Valid from serial number Date Order number
815,816 6070557- 2009-12-22 7510399-040
Indica- | Cause Tip
tor.
2:582 _ | Key relay input status Is not the same | 1, Inspect the fuse [F74]
between the MCU and CID
2. Verify that conductor 28 from the fuse
{F74] to the MCU input [131:6] is in-
tact.
3. Verify that conductor 28 from the fuse
[F74] to the CID input [X504:7] is in-
tact,Troubleshooting
Troubleshooting using error code
Ordernumber Date Valid from serial number T-code
7510399-040 2009-12-22 6070557- 815,816
8.5.3 Drive system error
Indica- | Cause Tip
tor.
3:080 Safety pedal actuated for more than Check input A6 via the CID diagnostic dis-
20 minutes.
play 3, pos 6
a
When the pedal is pressed down, the sig-
nal should be approx. 3.5 V and when
released the signal should be approx.
15V.
If the signal does not change:
+ Verify that the cabling and terminals are
intact
+ Replace the safety pedal [B31].
+ Replace the MCU.
Ifthe signal does change:
+ Log out and disconnect the battery for
approx. 1 minute.
+ Reconnect the battery, log in and check
whether the error indication has disap-
peared.
+ Update the truck firmware to the latest
available version.
+ Replace the MCU.Troubleshooting
Troubleshooting using error code
Teode Valid from serial number Date Order number
815, 816 6070587- 2009-12-22 7510399-040
Indica- | Cause Tip
tor.
3.081 | Seat switch actuated for more than | Check input DI12 via the CID diagnostic
20 minutes. display 4, pos 12:
S| 010110
4 oog@Loo0
oooL1000
:O--
When the seat is occupied, the signal
should be 1’ and when unoccupied it
should be ‘0’
If the signal does not change:
+ Verify that the cabling and terminals are
intact.
+ Replace the seat switch [B49],
+ Replace the MCU.
Ifthe signal does change:
+ Log out and disconnect the battery for
approx. 1 minute.
+ Reconnect the battery, log in and check
whether the error indication has disap-
peared
+ Update the truck firmware to the latest
available version.
+ Replace the MCU.
3:142 | Short circuit in the left support arm | 1. Check that the resistance of the brake
bral coll [16] is between 44 and 52 ohm.
Max travel speed is limited to 9 kmih.
3:143 | Short circuit in the right support arm | 1. Check that the resistance of the brake
brake. coll 17] is between 44 and 52 ohm.
Max travel speed is limited to 9 kmh.
3:162 | Breakin the left support arm brake, | 1. Check thal the resistance of the brake
Max travel speed is limited to 9 km/h, coil (Q16] is between 44 and 52 ohm.
3163 | Breakin the right support arm brake. | 1. Check that the resistance of the brake
Max travel speed is limited to 9 km/h. coil (Q17] is between 44 and 52 ohm.Order number
7510399-040
Indica-
tor.
Date
2009-12-22 6070557-
Cause
Valid from serial number
Troubleshooting
Troubleshooting using error code
Tcode
815, 816
Tip
3180
3:30
‘Safety pedal output voltage incorrect.
Faulty reversing brake.
The truck is braked using the mechani-
cal brake and driving is disabled,
Verify that the safety pedal output volage
is within 1.5 V to 3.5 V. CID diagnostic dis-
play 3, pos 6:
aI
3
10:51.21
If the output voltage is outside the lim-
its:
+ Verify that the voltage is between 4.5 V
and 5.5 V between [B31:1] and [B31:3].
+ Inspect [X130:31], conductor 84 for in-
terruptions, short-circuits or incorrect
power supply.
If the output voltage is within the limits,
but does not change when the pedal is
operated:
+ Replace the pedal [B31].
+ Update the truck firmware to the latest
available version.
+ Replace the MCU.
1. Check the battery charge status. ifthe
battery is fully charged when the motor
brakes strongly, this may be the cause
of the error.
2. Check the battery cables and their
connections.
3. Check the three phase connections
between the motor and the ACT.
4, Replace ACT.
3:305
Motor temperatur over 180°C.
The truck is braked by the motor brake
until it stops.
Cheek that the resistance in the drive
motor’s temperature sensor is be-
tween 550 ohms and 650 ohms. At
150°C the resistance should be 600
ohm,
2. Check that the fan for the motor com-
partment works and that the ventilation
‘openings are not blocked
3, Check that the drive motor is not dam-
aged.Troubleshooting
Troubleshooting using error code
Teode Valid from serial number
815, 816 6070557-
Indica- | Cause
tor.
Date Order number
2009-12-22 7510399-040
Tip
3:314 | The MCU or ACT have not responded
- | via CAN2 within 70 ms.
3:316 | The truck is braked by the motor brake
unti it stops.
3:320 | ACT — Voltage for motor supply out-
= side specified limits.
3:322 _ | The truck is braked by the motor brake
Until it stops.
7. Check fuse [F73].
2. Check that CAN 2 is intact in terms of
wiring hamess, final resistance and
contacts. Disonnect the battery. Check
that the resistance between [X130:8]
and [X130:22] is 54 — 66 ohm,
3. Check that the ACT's green LED is it
constantly
If the LED is not lit:
+ Check that the ACT has a supply volt-
age of 48 V between [K1:3] and [B+]
+ Replace ACT.
If the LED is lit:
+ Replace ACT.
Check
4, Fuse F71
2 F4
3. That the main contactor {Q10] is
closed and that the contacts are not
burned.
4, That the wiring hamess between the
battery and the ACT are complete and
not oxidised.
3:323 | Overcurrent - ACT.
The truck is braked by the motor brake
until it stops.
Check
1. That the battery voltage is correct
when connected to the ACT.
2. That the battery wiring hamess is un-
damaged and there is no relationship
between B+ and B-.
3. That the motor cables are undamaged
and there is no relationship between
them or with Be
4. The motor windings’ resistance to the
motor yoke, there should be no rela-
tionship.
5. Test using a new motor controller. If
the error persists, the fault is probably
an internal motor problem. Replace
the motor and refit the old controller.Troubleshooting
Troubleshooting using error code
Order number Date Valid from serial number T-eode
7510399-040 2009-12-22 6070557- 815,816
Indica- | Cause Tip
tor.
3325 | The ACT's cooling element is over | Check that the cooling fan for the ACT
125°C. and ACH is working normally. CID Service
The truck is braked by the motor brake | function:
until it stops.
If the fan is working normally:
+ Clean the ACT's cooling element and
associated ducts. Ifthe error returns the
fault is probably an internal ACT prob-
tem.
If the fan does not work normally:
+ Ifthere is not 48 V between [G3:1] and
{G3:2]: Check the wiring harness and
the MCU.
+ Ifthere is not 48 V between [G3:1] and
[3:2]: Check the fan
3:328 | Short circuit in the ACT, the drive Check
motor or the motor cables.
4. That the motor cables are undamaged
he tuck Is braked by the motor brake and there is no short circuit between
unt it stops. them or with B-.
2. The motor windings’ resistance to the
motor yoke, there should be no rela-
tionship,
3, Test using a new motor controller. If
the error persists, the fault is probably
an internal motor problem. Replace
the motor and refit the old controller.
3:329__| Measurement/Calibration error in the | 1. Log off and make the truck without
ACT's current measurement. voltage for at least 1 minute.
The trucks braked by the motor brak® | > Restart the ruck and og in again,
SoS If the fault persists:
+ Replace ACT.Troubleshooting
Troubleshooting using error code
T-code Valid from serial number Date Order number
815,816 6070557- 2009-12-22 7510399-040
Indica- | Cause Tip
tor.
3:331 | The ACT's internal 5 volts is outside | Check
the specified limits. .
The truck is braked by the motor brake Fuse F73
until it stops + The battery voltage (ACT K1:9] and B-
If the voltage deviates from the battery
voltage:
+ Check that cable 27, between the fuse
box and the ACT, is undamaged and
that the connections are not oxidised.
If the voltage is the same as the battery
voltage:
+ Replace ACT.
3:333__| The ACT's internal 15 volts Is outside | Check
the specified limits .
The truck is braked by the motor brake peel)
until it stops, + The battery voltage (ACT K1:9] and B-
If the voltage deviates from the battery
voltage:
+ Check that cable 27, between the fuse
box and the ACT, is undamaged and
that the connections are not oxidised
If the voltage is the same as the battery
voltage:
+ Replace ACT.
3:380 | Break or short circuit in the speed __| Loosen the sensor and remeasure [B11:1]
sensor [B11].
Max travel speed is reduced to 10.5km/
h
and [B11:4], '1' = + and °a' = -. The resist-
ance should be approx 160 kohm.
If the resistance measurement sug-
gests a breakishort circuit in the sen-
sor:
+ Replace the sensor.
If the resistance measurement
excludes a break/short circuit:
+ Check conductors “10” and "11",
[B11:1)(K1:11] and [811:4)/[K 1:6), for
any break/short circuit.
If the conductors are undamaged:
+ Replace ACT.Troubleshooting
Troubleshooting using error code
Order number Date Valid from serial number T-eode
7510399-040 2009-12-22 6070557- 815,816
Indica- | Cause Tip
tor.
3385 __| The voltage from the accelerator Check that the accelerator pedals output
pedal [B32] is outside the specified
Driving is blocked and the truck is
braked to a stop with the motor brake,
Voltage is between 0.25 V to 4.75 V. CID's
diagnostic screen 3, pos 5:
aI
1.52
0.50
4.50
0.00
If the output voltage is outside these
+ Check that the voltage is between 4.5 V
and 5.5 V between [B32:6] and [B32:1]
+ Check that there is no break, short cir-
cuit or incorrect feed to [X130:17], con-
ductor 87/GY.
If the output voltage is within limits, but
that changes when the pedal is
affected:
+ Replace the pedal [B32]
+ Download new software to the MCU. If
this involves an update, the software for
the CID must also be changed.
+ Replace MCU.Troubleshooting
Troubleshooting using error code
Teode Valid from serial number Date Order number
815, 816 6070587- 2009-12-22 7510398-040
Indica- | Cause Tip
tor.
3:387 | The voltage from the brake pedal Check that the brake pedal's signal 1 out-
[B32], signal 1, is outside the speci-
Ss.
Driving is blocked and the truck is
braked to a stop with the motor brake.
put voltage is between 0,25 V to 4.75 V.
CID's diagnostic screen 3, pos 7:
al
: 0,00
3.14
0.00
Or?
5: 0.50
If the output voltage is outside these
Ss:
+ Check that the voltage is between 4.5 V
and 5.5 V between [B32:6] and [32:1]
+ Check that there is no break, short cir-
cuit or incorrect feed to [X130:4], con-
ductor 85/WH.
Ifthe output voltage is within limits, but
that changes when the pedal
affected:
+ Replace the pedal [B32]
+ Download new software to the MCU. If
/olves an update, the software for
the CID must also be changed
+ Replace MCU.Troubleshooting
Troubleshooting using error code
Order number Date Valid from serial number T-code
7510399-040 2009-12-22 6070557- 815, 816
Indica- | Cause Tip
tor.
3388 | The voltage from the brake pedal Check that the brake pedals signal 2 out-
[B32], signal 2, is outside the speci-
fied limits.
Driving is blocked and the truck is
braked to a stop with the motor brake,
put voltage is between 0.25 V to 4.75 V.
CID's diagnostic screen 3, pos 8:
oft: 9.00 1.52
3.14 0.50
2 |3: 0.00 4.50
a.77 7.00
520.50 10:s1.21
If the output voltage is outside these
+ Check that the voltage is between 4.5 V
and 5.5 V between [B32:6] and [B32:1]
+ Check that there is no break, short cir-
cuit or incorrect feed to [X130:18], con-
ductor 86/8K.
If the output voltage is within limits, but
that changes when the pedal is
affected:
+ Replace the pedal [B32]
+ Download new software to the MCU. If
this involves an update, the software for
the CID must also be changed.
+ Replace MCU.Troubleshooting
Troubleshooting using error code
Teode Valid from serial number Date Order number
815, 816 6070587- 2009-12-22 7510398-040
Indica- | Cause Tip
tor.
3:389 | Too large discrepancy between both | Check that both the brake pedal signals"
brake pedal signals.
Driving is blocked and the truck is
braked to a stop with the motor brake.
output voltages follow each other and that
one is inverse to the other,
™
. ”
Ruy
‘apos)
V = brake peda's output voltage,
pos = Brake pedal depression
The CID's diagnostic screen 3, pos 7 and
8
a
2
If the output voltage does not change
normally:
+ Check that the voltage is between 4.5 V
and 5.5 V between [B32:6] and [32:1],
+ Check that there is no poor relationship
or faulty supply of [X130:4], conductor
85/WH and [X130:18], conductor 86/
BK.
+ Replace the pedal [B32].
Ifthe output voltage changes normally:
+ Download new software to the MCU. If
this involves an update, the software for
the CID must also be changed.
+ Replace MCUOrder number
7510399-040
Indica-
tor.
Date
2009-12-22
Cause
Valid from serial number
6070557-
Troubleshooting
Troubleshooting using error code
Tcode
815, 816
Tip
3:390
3:500
Voltage from the travel direction
selector [B36] is outside the indicated
Truck travel disabled and truck brakes to
standstill using the motor brake.
Unknown ACT error.
Verify that the travel direction selector out-
put voltage is within 0.25 V to 4.75 V when
the selector is moved between its end
positions. CID diagnostic display 1, pos 6:
If the output voltage is outside the lim-
its:
+ Verify that the voltage is between 4.5 V
and 5.5 V between [A61:1] and [A6:4],
+ Inspect [X505:4], conductor 94/GY for
interruptions, short-circuits or incorrect
power supply.
Ifthe output voltage is the limits,
but does not change when the selector
is operated:
+ Replace the A6 logic card including
the sensor.
+ Update the truck firmware to the latest,
available version.
+ Replace the MCU.
1. Update the truck firmware to the latest
available version.
2. Replace the ACT.
3:520
‘ACT start up error.
Check that the ACT's green LED is lit con-
stantly
Ifthe LED is not lit:
+ Check fuse [F73]
+ Check that the ACT has a supply volt-
age of 48 V between [K1:9] and [B-].
+ Replace ACT.
Ifthe LED is lit:
+ Replace ACT.
+ Check that CAN 2s intact in terms of
wiring hamess, final resistance and
contacts, Disonnect the battery. Check
that the resistance between [X130:8]
and [X130:22] is 64 — 66 ohm.